MICROCABLES A complete vision of your connectivity needs Catalogue
MICROCABLES A complete vision of your
connectivity needs
Catalogue
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 2 -
ELECTRONIC
Filotex®
Introduction
Application
Nexans’s line of microcables is designed towards the increasing requirements of electronics applications for miniaturization, reliability, performance, flexibility, higher density and EMI protection. From Medical to Instrumentation, Computers to Automated Test Equipment, Nexans offers solutions for the most demanding electronics applications. From 32 to 46 AWG, using high strength alloys and extruded fluorine resins insulation, in flat or round constructions, our development and design engineers are at your disposal to provide their experience in tailoring any of our products to meet your precise requirements. ü Electronics: - cables for instrumentation and test equipment
applications (rack bus, positioning sensor, logic analysers,…);
- cables for internal equipment or device-to-device connections.
ü Computer and audio/video appliances (CD ROM-to-Laptop connection, LCD panels protection, DVD connections,...). ü Ultrasound (external or internal applications for OB/Gyn, cardiology, veterinary, imaging applications,…). ü CCD cameras applications (CCD cameras for medical, industrial, endoscopy and video-surveillance applications). ü Other medical: Cardiac monitoring, pace makers, ECG/EKG,…
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 3 -
ELECTRONIC
Filotex®
Advantages
Construction
ü Wide range of conductors and dielectric materials; ü Unique patented extrusion technology for low capacitance cables; ü Ultra-flexible cables; ü High speed transmission cable; ü Space and weight saving;
ü High electrical performances (ε r up to 1.5) ü Various styles available; ü Good physical properties (different jacket material for mechanical, chemical and climatic requirements). Single wires or coaxial cables assembled in a variety of constructions. Screened or unscreened wires available. Nexans designs round cable consisting of up to 528 elements and featuring an extremely small overall diameter of 13.0 mm/0.51”. The microcables product line includes coaxial cables with an OD as small as 0.19mm/.007”.
Hook-up wires ü Singlecore unscreened from AWG 46 to AWG 32 ü Singlecore screened and jacketed
from AWG 46 to AWG 32
Multicore and coaxial cables ü From 2 to 528 conductors ü From AWG 46 to AWG 32 inner conductor ü Unscreened and jacketed or screened and jacketed Composite cables Assembly of quads, pairs, coaxial… Pa
ssin
g on
or
copy
ing
of th
e do
cum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itted
with
out p
rior
writ
ten
auth
oriz
atio
n. In
form
atio
n su
bjec
t to
chan
ge w
ithou
t not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 4 -
ELECTRONIC
Filotex®
Technology Inner conductor: silver plated alloy, stainless steel, silver plated copper (stranded or not)
Insulation: FEP, PFA, PE (plain or special melt extrusion)
Assembly: PTFE tape
Drain wire*: silver plated alloy, silver plated copper
Mechanical support*: aramid strength member in option
Elect. Protection: polyester/aluminium tape, silver plated copper or alloy screen, tin plated copper screen or stainless steel screen Jacket: FEP, PFA, PVC, PUR, PE, TPE, PA
* Optional
Main characteristics
ü Impedance : 50 Ω to 130 Ω ü Capacitance : 27 pF/m to 110 pF/m (8 pF/ft to 33pF/ft) ü Operating voltage : from 24 V to 250 V ü Operating temperature : from – 60°C to +200°C
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 5 -
ELECTRONIC
Filotex®
Summary
Part 1 Part 2 Part 3 Part 4 Part 5 Part 6
Microcables for all markets: single coaxials - Normal capacitance: 95pF/m - Low capacitance: 55pF/m Microcables for electronic application Microcables for computer application Microcables for ultrasound
Microcables for CCD cameras applications - Microcables for Endoscopy - Microcables for Dental application Microcables for other medical applications - Microcables for catheter - Microcables for patient monitoring (invasive
applications) - Microcables for ECG - Temporary myocard pacing wire
Page 6
Page 7 Page 14
Page 16
Page 20
Page 23
Page 34 Page 35 Page 42
Page 47 Page 48 Page 51 Page 53 Page 55
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 6 -
Part 1
Microcables for all markets:
single coaxials
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 7 -
Normal capacitance 95pF/m
All cables are also available in solid conductor version.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 8 -
Filotex®
STUDY 123836
32 AWG coax cable
Micro coaxial cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m AWG 32 stranded silver plated alloy. FEP insulation ∅ = .65 ±.02mm 44 AWG silver plated copper Helicoidal screen ∅ = .75mm nominal FEP jacket ∅ = .91 ± .03mm
Thermal performances r Operating temperature : - 50°C to + 200 °C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Black – Brown - Red - Orange - Yellow - Green - Blue -
Violet - Grey - White – Translucide r Jacket : White
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 123 836
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 9 -
Filotex®
STUDY 132474
34 AWG coax cable
Micro coaxial cable
Characteristics r Very flexible cable with an extremely good mechanical
behaviour.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m 34 AWG(7 x .06 mm)
stranded silver plated copper PFA insulation ∅ = .53 ± .02mm 44 AWG silver plated copper
braid Helicoidal screen ∅ = .75mm nominal PFA jacket ∅ = .85 ± .03 mm
Thermal performances r Operating temperature : - 50°C to + 200°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Green r Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue -
Violet - Grey - White – Translucide
PRODUCT REFERENCES FILOTEX Ref : ET 132 474
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 10 -
Filotex®
STUDY 124954 36 AWG coax cable
Micro coaxial cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
Thermal performances r Operating temperature : - 50°C to + 200 °C
CONSTRUCTION
Multi coax 95 Pf/M AWG 36 stranded silver plated copper. FEP insulation ∅ = .44 ± 02mm 44 AWG silver plated copper Helicoidal screen ∅ = .54mm nominal FEP jacket ∅ = .63 ± .03 mm
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Red or Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue -
Violet - Grey - White - Translucide
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 124 954
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 11 -
Filotex®
STUDY 122882
38 AWG coax cable
Micro coaxial cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes
Applications r Ultrasound cable assemblies
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Multi coax 95pF/m AWG 38 stranded silver
plated alloy FEP insulation ∅ = .34 ± .02mm 44 AWG silver plated copper
Helicoidal screen ∅ = 44mm nominal FEP jacket ∅ = .53 ± .02mm
Thermal performances r Operating temperature : - 50°C to + 200 °C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colors r Dielectric : Red or Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue -
Violet - Gray - White - Translucide
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 122 882
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 12 -
Filotex®
STUDY 132469
40 AWG coax cable
Micro coaxial cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m AWG 40 silver plated alloy
135 wire PFA insulation. ∅ = .23 ± 02mm 48 AWG silver plated copper
Helicoidal screen ∅ = .29mm nominal PFA jacket ∅ = .36 ± .03 mm
Thermal performances r Operating temperature : - 50°C to + 200°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Green r Jacket : Black - Brown - Red - Orange – Yellow - Green - Blue -
Violet - Grey - White – Translucide
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 132 469
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 13 -
Filotex®
STUDY 132358
42 AWG coax cable
Micro coaxial cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m AWG 42 stranded silver
plated alloy PFA insulation ∅ = .21mm 48 AWG silver plated copper
Helicoidal screen ∅ = .27mm nominal FEP jacket ∅ = .35 ± .03 mm
Thermal performances r Operating temperature : - 50°C to + 200°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Green r Jacket : Black - Brown - Red - Orange - Yellow - Green - Blue -
Violet - Grey - White - Translucide
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 132 358
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 14 -
Low capacitance 55pF/m
All cables are also available in solid conductor version.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 15 -
Filotex®
STUDY 132475
40 AWG coax cable
Micro coaxial cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%)(17pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn r Max DC resistance : 1.2 Ω/ft
CONSTRUCTION
Multi coax 55 pF/m AWG 40 silver plated alloy
135 wire PFA “SE” insulation ∅ = .36 ± .02mm 48 AWG silver plated copper
Helicoidal screen ∅ = .42mm nominal PFA jacket ∅ = .47 ± .03 mm
Thermal performances r Operating temperature : - 50°C to + 200°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Red r Jacket : Black - Brown - Red - Orange – Yellow - Green – Blue -
Violet – Grey - White – Translucide
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 132 475
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 16 -
Part 2
Microcables for electronic application
Linear capacitance : ET 132211 27pF/m ET 132084 33pF/m ET 124810 55pF/m
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 17 -
Filotex®
STUDY 132211
41 AWG coax cable
Cable for electronic application Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Electrical performances r Characteristic impedance : 130 ± 10 Ω r Max linear capacitance : 27 pF/m (8 pF/ft) r DC resistance : 130 ± 8 Ω/m r Continuous operating voltage : 30 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Coax 130 Ω AWG 41 constantan FEP “SE” insulation ∅ = .95 ±.05mm 44 AWG silver plated copper Helicoidal screen ∅ = 1.05mm nominal PVC jacket ∅ = 1.40mm max
Thermal performances r Operating temperature : - 50°C to + 80°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Yellow r Jacket : Flint Grey
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 132 211
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 18 -
Filotex®
STUDY 132084
41 AWG coax cable
Cable for electronic application Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Electrical performances r Characteristic impedance : 130 ± 10 Ω r Linear capacitance : 33 ± 3 pF/m (10pF/ft) r DC resistance : 130 ± 8 Ω/m r Continuous operating voltage : 30 V eff. r Test voltage between core and screen :350 V DC 1 mn
CONSTRUCTION
Coax 130 Ω AWG 41constantan FEP “SE” insulation ∅ = .70 ±.03mm 44 AWG silver plated copper Helicoidal screen ∅ = .80mm nominal PVC jacket ∅ = 1.1 ± .05mm
Thermal performances r Operating temperature : - 50°C to + 80°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
Standard colours r Dielectric : Red r Jacket :Flint Grey
¬ ® ¯
PRODUCT REFERENCES FILOTEX Ref : ET 132 084
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 19 -
Filotex®
STUDY 124810
4 channels 38 AWG coax cable
Cable for electronic application
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Cable for displacement sensor.
Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft) r Current capacity : > 250 mA r Continuous operating voltage : 250 V DC.
CONSTRUCTION
Multi coax 55 pF/m
Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .51 ± 02mm AWG 48 silver plated copper Helicoidal screen ∅ = .57mm nominal FEP jacket ∅ = .62 ± 02mm 4 Cores A twisted ∅ = 1.5mm PTFE tape ∅ = 1.55mm nominal AWG 41 tin plated copper braid 90 % coverage ∅ = 1.8mm nominal Medical P.V.C ∅ = 2.8 ± .15mm
Thermal performances r Operating temperature : - 20°C to + 75 °C
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 810
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 20 -
Part 3
Microcables for computer application
Linear capacitance : ET 132433 55 pF/m ET 132167 100 pF/m
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 21 -
Filotex®
STUDY 132433
49 channels 42 AWG coax cable + 8 x 28 AWG wires
Cable for computer application (input/output)
Characteristics r Very flexible cable with an extremely good mechanical behaviour.
Electrical performances r Characteristic impedance cores A : 80 Ω nominal r Linear capacitance cores A : 55 ± 5 pF/m (at 95%).(17 pF/ft) r DC resistance cores A : <= 7.8 Ω/m (2.5 Ω/ft) r Continuous operating voltage cores A : 24 V eff. r Continuous operating voltage cores B : 250 V DC r DC resistance cores B : <= .25 Ω/m (.076 Ω/ft) r Test voltage between core and screen : 350 V DC 1 mn r Insulation resistance : > 1000 MΩ.km
CONSTRUCTION
Multi coax 55 pF/m Core A : AWG 42 (1 x 0.064 mm) silver plated Alloy. PFA " SE " insulation ∅ = .26 ± .02mm AWG 48 silver plated copper Helicoidal screen ∅ = .32 mm nominal PFA jacket ∅ = .36 ± .02mm Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. PFA insulation ∅ = .59 ± .03 mm Core C : 8 Cores A twisted ∅ = 1.1 mm Core D : 9 Cores A twisted ∅ = 1.3 mm 5 cores (C) + 1 cores (D) + 8 cores (B) twisted ∅ = 4.0 mm nominal PTFE tape ∅ = 4.06 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 4.40 mm nominal PVC jacket ∅ = 5.9 ± .2 mm
Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 433
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 22 -
C
Filotex®
STUDY 132167
49 channels 42 AWG coax cable + 8 x 28 AWG wires
Cable for computer application (input/output)
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Electrical performances r Characteristic impedance cores A : 50 Ω nominal r Linear capacitance cores A : 100 ± 10 pF/m (at 95%).(30.5pF/ft) r DC resistance cores A : <= 7.8 Ω/m r Continuous operating voltage cores A : 24 V eff. r Continuous operating voltage cores B : 250 V DC r DC resistance cores B : <= .25 Ω/m r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Multi coax 100 pF/m
Core A : AWG 42 (1 x 0.064 mm) silver plated Copper. FEP insulation ∅ = .19 ± .02mm AWG 48 tin plated copper Helicoidal screen ∅ = .25mm nominal FEP jacket ∅ = .30 ± .02mm Core B : AWG 28 (7 x 0.13 mm) stranded tin plated copper. FEP insulation ∅ = .59 ± .03mm Core C : 8 Cores A twisted ∅ = 0.9mm Core D : 9 Cores A twisted ∅ = 1.1mm 5 cores (C) + 1 cores (D) + 8 cores B twisted ∅ = 3.75mm nominal PTFE tape ∅ = 3.8mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 4.15mm nominal PVC jacket ∅ = 5.5 ± .2mm
Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 167
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 23 -
Part 4
Microcables for Ultrasound
Applications : q Veterinary application
(mechanical probes) q Transvaginal application q Endocavity application
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 24 -
Filotex®
STUDY 124311
11 channels 34 AWG coax + 8 x 26 AWG wires
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
CONSTRUCTION
Ultra sound cable Core A : AWG 34 stranded silver plated alloy. PTFE insulation ∅ = .52 ±.02mm AWG 43 silver plated copper braid FEP jacket ∅ = 1.02 ±.05 mm Core B : AWG 26 stranded tin plated copper. PVC insulation ∅ = .90 ±.10mm Fillers 7 cores (A) + 1 filler twisted AWG 40 tin plated copper helicoidal screen 90 % coverage 4 cores (A) + 8 cores (B) + fillers twisted around PTFE tape AWG 40 tin plated copper braid 95 % coverage Medical PVC ∅ = 7.45 ±3mm
Mechanical performances q Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 311
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 25 -
Filotex®
STUDY 124973 26 channels 36 AWG coax cable
+ 20 wires 30 AWG
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m
Core A : AWG 36 stranded silver plated copper. FEP insulation ∅ = .44 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .54mm nominal FEP jacket ∅ = .63 ± .03 mm Core B: AWG 30 stranded silver plated copper. FEP insulation ∅ = .5 ± 1mm Core C: 3 cores A twisted Core D: 4 cores B twisted Core E: 3 cores B twisted Core F: 2 cores A + 1 core B twisted 8 Cores (C) + 4 cores D + 1 core E + 1 core F twisted ∅ = 5.2 mm nominal PTFE tape ∅ = 5.25 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 5.6mm nominal Medical PVC ∅ = 7.0 ± .3mm
r DC resistance core (A) : 1.5 Ω/m r DC resistance core (B) : .4 Ω/m
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 973
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 26 -
Filotex®
STUDY 124733
33 channels 40 AWG coax + 12 x 36 AWG wires
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
CONSTRUCTION Ultrasound cable
Core A : AWG 40 stranded silver plated alloy. FEP insulation ∅ = .25 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .31 mm nominal FEP jacket ∅ = .39 ± .02 mm Core B : AWG 36 stranded silver plated. FEP insulation ∅ = .40 ± .02mm Core (C) 7 cores (A) twisted Core (D) 6 cores (B) +Cotton filler twisted Core (E) 5 cores (A) +Cotton filler twisted 4 Cores (C) + 2 cores (D) + 1 core (E) twisted ∅ = 3.50 mm nominal PTFE tape ∅ = 3.7 mm nominal.
AWG 44 tin plated copper braid
85 % coverage
∅ = 3.9 mm nominal
Medical PVC ∅ = 4.9 ± .1mm
Electrical performances r Characteristic impedance core (A) : 50 Ω nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 733
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 27 -
Filotex®
STUDY 123992 66 channels 38 AWG coax cable
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical
behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION Multi coax 95 pF/m
Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = .44mm nominal FEP jacket ∅ = .53 ± .02mm Core B : 8 Cores A twisted ∅ = 1.6mm Core C : 2 Cores A twisted ∅ = 1.05mm 8 cores (B) + 1 cores (C) twisted ∅ = 5.3mm nominal PTFE tape ∅ = 5.35mm nominal. AWG 40 tin plated copper braid.85 % coverage ∅ = 5.7mm nominal Medical P.V.C ∅ = 8 ± .2mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 123 992
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 28 -
Filotex®
STUDY 124480 84 channels 38 AWG coax cable
Medical Ultrasound cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies. Electrical performances r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
CONSTRUCTION
Multi coax 95 pF/m
Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = 44mm nominal FEP jacket ∅ = .53 ± .02mm Core B : 8 Cores A twisted ∅ = 1.6mm Core C : 2 Cores A twisted ∅ = 1.05mm 10 cores (B) + 2 cores (C) twisted ∅ = 6.0mm nominal PTFE tape ∅ = 6.05 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 6.4mm nominal Medical P.V.C ∅ = 8.0 ±.2mm
Mechanical performances r Minimum bending radius : 5 x Overall diameter r Flex life test : Standard test in accordance with drawing 250,000
cycles minimum Mover rollers ∅ 80 mm
Moving range : 550 mm
Cable length : 1600 mm Speed : .22 m/s (8 cycles/mn) Test weight (M) : 3000 g
PRODUCT REFERENCES FILOTEX Ref : ET 124 480
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 29 -
Filotex®
STUDY 124499
132 channels 38 AWG coax cable
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Multi coax 95 pF/m
Core A : AWG 38 silver plated copper wire. FEP insulation ∅ = .30 ±.02mm AWG 48 silver plated copper Helicoidal screen ∅ = .36mm nominal FEP jacket ∅ = .46 ± .02mm Core B : 4 Cores A twisted ∅ = 1.1mm Core C : 8 Cores A twisted ∅ = 1.4mm 1 cores (B) + 16 cores (C) twisted ∅ = 6.5mm nominal PTFE tape ∅ = 6.6mm nominal. AWG 41 tin plated copper braid 85 % coverage ∅ = 7.0mm nominal
Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 499
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 30 -
Filotex®
STUDY 132029 132 channels 40 AWG coax cable
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical
behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies. r Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 55 ± 5 pF/m (at 95%).(17pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V AC 1 mn r Max DC resistance of centre conductor : 1.2 Ω/ft
CONSTRUCTION
Multi coax 55pF/m Core A : AWG 40 stranded silver plated alloy PD 135. FEP « SE » insulation ∅ =.34 ± .03 mm AWG 48 silver plated copper Helicoidal screen ∅ =.40mm nominal FEP jacket ∅ = .46 ± .03mm Core B : 4 Cores A + Kevlar member tensile strength 50 kgF twisted ∅ = 1.15mm Core C : 8 Cores A twisted ∅ = 1.5mm 1 core (B) + 16 cores C twisted ∅ =6.3mm nominal PTFE tape ∅ = 6.35 mm nominal. AWG 40 silver plated alloy braid 85 % coverage ∅ = 6.7mm nominal Medical P.V.C ∅ = 8.5 ±.25mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 029
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 31 -
Filotex®
STUDY 124590
132 channels 42 AWG coax cable
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION Multicoax 95 pF/m
Core A : AWG 42 silver plated copper wire. FEP insulation ∅ = .20 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .26 mm nominal FEP jacket ∅ = .34 ± .02 mm Core B : 4 Cores A twisted ∅ = .8 mm Core C : 8 Cores A twisted ∅ = 1 mm 1 cores (B) + 16 cores (C) twisted ∅ = 4.7 mm nominal PTFE tape ∅ = 4.8 mm nominal.
AWG 40 silver plated alloy braid
85 % coverage
∅ = 5.2 mm nominal
Medical P.V.C ∅ = 7.2 ± .3 mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 590
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 32 -
Filotex®
STUDY 124541 192 + 4 channels 40 AWG coax cable
Medical Ultrasound cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes. Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 80 Ω nominal r Linear capacitance : 18 ± 2 pF/ft (at 95%) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 500 V AC 1 mn r Max DC resistance of centre conductor : 1.2 Ω/ft r Max DC resistance of coax shield : 15 Ω/ft r Insulation resistance : > 10 MΩ
CONSTRUCTION
Multi coax 55pF/m Core A : AWG 40 stranded 7x.03mm silver plated alloy PD 135. FEP « SE » insulation ∅ = .34 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ =.40mm nominal FEP jacket ∅ = .46 ± .02mm Core B : 16 Cores A twisted ∅ = 2.1mm Core C : 4 Cores A twisted ∅ =.95mm 12 cores (B) + 1 core C twisted ∅ =7.7mm nominal PTFE tape ∅ = 7.75mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 8.1mm nominal Medical PVC ∅ = 9.6 ±.3mm
r Crosstalk coax to coax , 1 ~ 10 Mhz in 96 inches long cable will all ends terminated in 80 Ω : < 55 dB
r One way signal loss (1 ~ 10 Mhz) : < 0.10 dB/ft Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 541
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 33 -
Filotex®
STUDY 132081
256 + 8 channels 40 AWG coax cable
Medical Ultrasound cable
Characteristics r Very flexible cable with an extremely good mechanical
behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies.
Electrical performances r Characteristic impedance : 50 Ω nominal r Linear capacitance : 95 ± 10 pF/m (at 95%).(29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn r DC resistance : <= 1.2 Ω/ft
CONSTRUCTION
Multicoax 95pF/m Core A : AWG 40 stranded silver plated alloy. FEP insulation ∅ = .24 ± .02 mm AWG 48 silver plated copper Helicoidal screen ∅ = .3 mm nominal FEP jacket ∅ = .39 ± .02 mm Core B : 16 Cores A twisted ∅ = 1.9 mm Core C : 8 Cores A twisted ∅ = 1.2 mm 16 cores (B) + 1 core (C) twisted ∅ = 7.6 mm nominal PTFE tape ∅ = 7.65 mm nominal. Medical P.V.C ∅ = 9.6 ± .30 mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 081
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 34 -
Part 5
Microcables for CCD cameras applications
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 35 -
Microcables for Endoscopy
Optional UL style approval : UL20379
Available models 3.5 mm ET 123602 5 mm ET 132468 ET 123540 ET 124991 ET 124692 7 mm ET 132028
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 36 -
Filotex®
STUDY 123602
9 channels 38 AWG coax + 5 x 38 AWG wires
Medical Video Endoscopy cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes
Applications r Video Endoscopy cable assemblies
Electrical performances r Characteristic impedance (core A) : 50 nominal r Linear capacitance (core A) : 95 ± 10 pF/m (at 95%) (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Video camera Cable
Core A : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.02mm AWG 44 silver plated copper Helicoidal screen ∅ = .44mm nominal FEP jacket ∅ = .53 ± .02 mm Core B : AWG 38 stranded silver plated alloy. FEP insulation ∅ = .34 ±.05mm Fillers 9 Cores (A) + 5 cores (B) + Fillers twisted ∅ = 2.05 mm nominal PTFE tape ∅ = 2.07 mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 2.5mm nominal Medical PVC ∅ = 3.45 ±.1mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter .
PRODUCT REFERENCES FILOTEX Ref : ET 123 602
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect
to c
hang
e w
ithou
t not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 37 -
Filotex®
STUDY 132468 1 channel 30 AWG coax
+ 11 x 28 AWG wires
Medical Video Endoscopy cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Video endoscopy cable assemblies
Electrical performances r Characteristic impedance core (B and D) : 50 Ω nominal r Linear capacitance core (B and D) : 110±10 pF/m (at 95%)
(33 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Video camera Cable
Core A : AWG 30 (19 x 42 AWG) stranded silver plated alloy. FEP insulation ∅ = .82 ±.05mm AWG 40 silver plated copper braid ∅ = 1.20mm nominal FEP jacket ∅ = 1.55 ± .05mm Core B: AWG 28 (19 x 40 AWG) stranded silver plated copper. FEP insulation ∅ = .60 ±.05mm 1 Core (A) + 11 cores (B) twisted ∅ = 2.75 mm nominal PTFE tape. ∅ = 2.90 mm nominal AWG 40 silver plated copper spiral shield ∅ = 3.25 mm nominal PTFE tape. ∅ = 3.4mm nominal Medical PVC ∅ = 5.45 ±.2mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 468
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 38 -
Filotex®
STUDY 123540
2 channels 34 AWG coax + 5 x 28 AWG wires
Medical Video Endoscopy cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes
Applications
r Video Endoscopy cable assemblies
Electrical performances r Linear capacitance core (A) : 100 pF/m nominal r DC resistance (A) : 95
Ω/100m nominal
CONSTRUCTION
Video camera Cable
Core A : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .53 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .63mm nominal PFA jacket ∅ = .98 ± .05mm Core B : AWG 28 stranded tin plated copper. PVC insulation ∅ = 1.1 ± .05mm 2 core (A) + 5 cores (B) twisted ∅ = 3.3 mm nominal PTFE tape ∅ = 3.35 mm nominal AWG 41 tin plated copper
braid 85% coverage ∅ = 3.7 mm nominal Medical PVC ∅ = 5.0±15mm
Thermal performances r Operating temperature : - 30°C to + 85°C
(100°C at peak) Mechanical performances r Minimum bending radius : 5 x Overall diameter .
PRODUCT REFERENCES FILOTEX Ref : ET 123 540
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 39 -
Filotex®
STUDY 124991 5 channels 30 AWG coax
+ 3 x 30 AWG wires
Medical video Endoscopy cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Medical cable assemblies.
Electrical performances r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Core A : AWG 30 stranded silver plated copper. FEP insulation ∅ = .80 ±.02mm AWG 38 silver plated copper helicoidal screen ∅ = 1.0 mm nominal FEP jacket ∅ = 1.2 ± .03 mm Core B: AWG 30 stranded silver plated copper. PTFE insulation ∅ = .81 ± .05mm 5 Cores (A) + 3 cores (B) twisted ∅ = 4.05 mm nominal PTFE tape AWG 40 tin plated copper braid 85% coverage ∅ = 4.4mm nominal Polyurethane ∅ = 5.7 ± .2mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 991
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 40 -
Filotex®
STUDY 124692 9 channels 32 AWG coax
+ 3 x 26 AWG wires
Medical Video Endoscopy cable Characteristics
r Very flexible cable with an extremely good mechanical behaviour.
r Withstands miscellaneous sterilisation processes.
Applications r Video endoscopy cable assemblies
Electrical performances r Characteristic impedance core (A) : 50 nominal r Linear capacitance core (A) : 95 ± 10 pF/m (at 95%).(29 pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Video camera Cable
Core A : AWG 32 stranded silver plated alloy. FEP insulation ∅ = .65 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ = .75mm nominal FEP jacket ∅ = .91 ± .05mm Core B : AWG 26 stranded tin plated copper. FEP insulation ∅ = .81 ±.05mm 9 Cores (A) + 3 cores (B) twisted ∅ = 3.6mm nominal PTFE tape ∅ = 3.65mm nominal. AWG 40 tin plated copper braid 85 % coverage ∅ = 4.1mm nominal Medical PVC ∅ = 5.0 ± .2mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 692
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 41 -
Filotex®
STUDY 132028 3 channels 28 AWG coax 6 channels 32 AWG coax
+ 3 x 26 AWG wires
Medical Video Endoscopy cable Characteristics
q Very flexible cable with an extremly good mechanical behaviour. q Withstands miscellaneous sterilization processes.
Applications q Video endoscopy cable assemblies.
Electrical performances q Characteristic impedance core (A) : 50 nominal q Linear capacitance core (A) : 80 pF/m nominal q Characteristic impedance core (B) : 50 nominal q Linear capacitance core (B) : 95 pF/m nominal q Continuous operating voltage : 30 V eff. q Test voltage between core and screen : 500 V AC 1 mn
CONSTRUCTION Video Camera Cable
Core A : AWG 28 stranded silver plated alloy. FEP insulation ∅ = 1.1 ± .05 mm AWG 40 silver plated copper Helicoidal screen ∅ = 1.26 mm nominal FEP jacket ∅ = 1.58 ± .05 mm Core B : AWG 32 stranded silver plated alloy. FEP insulation ∅ = .63 ± .05 mm AWG 44 silver plated copper Helicoidal screen ∅ = .73 mm nominal FEP jacket ∅ = .91 ± .05 mm Core C : AWG 26 stranded silver plated copper. FEP insulation ∅ = .80 ± .05 mm Cotton filler 3 Cores (A) + 6 cores (B) + 3 cores (C) twisted ∅ = 4.4 mm nominal PTFE tape ∅ = 4.45 mm nominal.
AWG 40 tin plated copper braid
85 % coverage ∅ = 4.8 mm nominal
Medical PVC ∅ = 6.8 ± .2 mm
Thermal performances q Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances q Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 028
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 42 -
Microcables for Dental application
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 43 -
Filotex®
STUDY 124844 1 channels 34 AWG coax
+ 8 x 34 AWG wires + 2 x 30 AWG wires
Dental cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Video endoscopy cable assemblies.
Electrical performances r Linear capacitance core (A) : 100 pF/m nominal r DC resistance core (A) : 95 Ω/100m nominal r DC resistance core (B) : 33.7 Ω/100m nominal r DC resistance core (C) : 95 Ω/100m nominal r Test voltage between braid and outside : 4000 V AC 1 mn
CONSTRUCTION
Video camera Cable Core A : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .53 ±.03mm AWG 44 silver plated copper Helicoidal screen nominal ∅ = .63mm PFA jacket ∅ = .83 ± .05mm Core B : AWG 30 stranded silver plated alloy. PFA insulation ∅ = .50 ± .05mm Core C : AWG 34 stranded silver plated alloy. PFA insulation ∅ = .36 ±.05mm 1 core (A) + 2 cores (B) + 8 cores (C) twisted ∅ = 2.05mm nominal 34 AWG silver plated alloy Drain wire PTFE tape ∅ = 2.10 mm nominal AWG 40 silver plated alloy braid 85 % coverage ∅ = 2.60 mm nominal Medical PVC ∅ = 4.1 ± .15mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 844
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 44 -
Filotex®
STUDY 1323312 channels 36AWG coax
+ 9 x 32 AWG wires + 10 x 32 AWG wires
Dental cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes
Applications r Video endoscopy cable assemblies
Electrical performances r Characteristic impedance : 60 nominal r Linear capacitance : 80pF/m nominal r Continuous operating voltage : 24 V eff. r DC resistance core (A) : 150 Ω/100m r DC resistance core (B) : 600 Ω/100m r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Video camera Cable Core A : AWG 36 stranded silver plated
alloy PFA insulation ∅ = .52 ± .03mm AWG 44 silver plated copper Helicoidal screen ∅ =.62mm nominal PFA jacket ∅ = .72 ± .05mm Core B : AWG 32 stranded silver plated
alloy PFA insulation ∅ = .42 ± .05mm 2 cores (A) + 9 cores (B) twisted ∅
= .2.3 nominal PTFE tape ∅ 2.35 mm nominal. AWG 40 silver plated copper braid 85% coverage ∅ = 2.7mm nominal 2 Medical PTFE tapes ∅=3.2 ± 3.2mm max Optional fillers 10 cores (B) around ∅= 4.05mm PTFE tape ∅ = 4.1mm nominal Medical PVC ∅ = 5.3 ± .2mm
Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
1
2
3
4
5
6
7
8
9
PRODUCT REFERENCES FILOTEX Ref : ET 132 331
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 45 -
Filotex®
STUDY 132116 2 x 36 AWG twisted pairs
+ 14 x 36 AWG wires
Dental cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Video endoscopy cable assemblies.
Electrical performances r Linear capacitance core (C) : 63 pF/m nominal r Linear capacitance between 2 cores (B) : 43 pF/m nominal r Linear capacitance between cores (B) and braid : 80 pF/mnominal r All capitance must be verify on a sample r DC resistance core (A) and (B) : 2.07 Ω/m nominal 2.2 Ω/m max
CONSTRUCTION
Video camera Cable Core A : AWG 36 stranded silver plated alloy. FEP insulation ∅ = .24 ±.03mm Core B : AWG 36 stranded silver plated alloy. FEP insulation ∅ = .28 ±.05mm Core C : 2 cores (A) twisted, pitch 5mm nominal (8 mm maxi) Kevlar member 158 TEX Tensile strength > 20 kgF 2 core (C) + 14 cores (B) + Kevlar member twisted, pitch 10mm nominal ∅ = 1.7mm max PTFE tape AWG 40 silver plated alloy braid 95 % coverage , pitch 10mm nominal ∅ = 2.2mm nominal PTFE tape ∅ = 2.4mm max Polyurethane ∅ = 3.6mm max Thickness .60 ± .05 mm
r Test voltage between braid and outside : 500 V AC r Spark test of jacket : 1500 V AC
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 116
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 46 -
Filotex®
STUDY 132182
8 x 36 AWG twisted pairs + 3 x 36 AWG wires
Dental cable
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes. Applications r Video endoscopy cable assemblies
Electrical performances r Linear capacitance core (C) : 60 pF/m maxi r Linear capacitance between 2 cores (B) : 15 pF/m nominal r Linear capacitance between cores (C) and braid : To be define on
sample r All capacitance must be verify on a sample r DC resistance core (A) & (B) : 1.52 Ω/m nominal . 1.6 Ω/m max. r Test voltage conductor/conductor : 500 VAC r Spark test of jacket : 1500 VAC
CONSTRUCTION
Video camera Cable Core A :AWG 36 stranded silver plated alloy. FEP insulation ∅ = .24 ± .03mm Core B :AWG 36 stranded silver plated alloy. FEP insulation ∅ = .28 ± .05mm Core C : 2 cores (A) twisted, pitch 8mm nominal(10 mm maxi) Kevlar member 158 TEX Tensile strength > 20 kgF Core D : 3 cores (B) twisted + Kevlar member, pitch 9mm nominal (12mm maxi) 1 core (D) + 8 cores (C) twisted, pitch 15 to 25mm ∅ = 1.7mm max PTFE tape unsintered AWG 42 hard silver plated alloy braid 95 % coverage , pitch 10mm nominal ∅ = 2.15mm nominal PTFE tape unsintered ∅ = 2.35mm max Polyurethane ∅ = 3.6mm max Thickness .60 ± .05mm All copper alloy are without cadmium.
Thermal performances r Operating temperature : - 30°C to + 85°C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
9
8
7
6
5
4
3
2
1
PRODUCT REFERENCES FILOTEX Ref : ET 132182
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 47 -
Part 6
Microcables for other medical applications
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 48 -
Microcables for Catheter
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 49 -
Filotex®
STUDY 132183 3 x 2 wires 44 AWG
Cable for catheter
Characteristics r Very flexible cable with an extremely good mechanical
behaviour. r Withstands miscellaneous sterilisation processes.
Applications r Ultrasound cable assemblies
Electrical performances r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
Thermal performances r Operating temperature : - 30°C to +150 °C (200°C at peak)
CONSTRUCTION Core A : AWG 44 silver plated copper. Enamel lacquer ∅ =.06 ±.005 mm Core B : 2 cores A twisted ∅ =.12mm 3 cores (B) twisted ∅ =.22mm nominal AWG 48 silver plated copper spiral shield ∅ = .28mm nominal FEP ∅ = .40 ± .02 mm
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 183
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 50 -
Filotex®
STUDY 124524 5 x 30 AWG wires
Cable for catheter
Characteristics r Very flexible cable with an extremely good mechanical
behaviour.
Electrical performances r Continuous operating voltage : 250 V
Thermal performances r Operating temperature : - 60°C to +85 °C
CONSTRUCTION Core A : AWG 30 stranded silver plated copper. PTFE insulation ∅ = .61 ±.05mm Core B : AWG 30 stranded silver plated copper drain wire. Core C : 2 cores (A) + 1 core (B) twisted Polyester/Aluminium tape 1 core (C) + 3 cores (A) twisted PTFE tape ∅ = 5.55 mm nominal AWG 38 tin plated copper helicoidal screen. Polyurethane ∅ = 3.55 ±.15mm
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 124 524
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 51 -
Microcables for patient monitoring
(invasive applications)
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 52 -
Filotex®
STUDY 123546
2 channels 36 AWG coax cable
Medical cable for patient monitoring
Characteristics r Very flexible cable with an extremely good mechanical behaviour r Withstands miscellaneous sterilisation processes
Applications r Ultrasound cable assemblies
Electrical performancess r Characteristic impedance : 50 nominal r Linear capacitance : 95 ± 10 pF/m (at 95%) (29pF/ft) r Continuous operating voltage : 24 V eff. r Test voltage between core and screen : 350 V DC 1 mn
CONSTRUCTION
Multi coax 95pF/m Core A : AWG 36 silver plated alloy wire. FEP insulation ∅ = .32 ±.03mm AWG 44 silver plated copper Helicoidal screen ∅ =.42mm nominal FEP jacket ∅ = .52 ± .03mm 2 Cores (A) + 2 cores (B) twisted ∅ = 1.02 mm nominal AWG 44 tin plated copper
helicoidal screen ∅ = 1.12mm nominal Superpolyamide ∅ = 1.5 ± 1 mm This cable is not round.
Thermal performances r Operating temperature : - 30°C to + 85 °C (100°C at peak)
Mechanical performances r Minimum bending radius : 5 x Overall diameter
3
2
1
PRODUCT REFERENCES FILOTEX Ref : ET 123 546
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 53 -
Microcables for ECG
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 54 -
Filotex®
STUDY 022595 ECG cable
Medical ECG cable
Characteristics r Very flexible cable with an extremely good mechanical
behaviour. r Withstands miscellaneous sterilisation processes.
Applications r ECG cable assemblies.
Electrical performances r Continuous operating voltage : 250 V eff.
Thermal performances r Operating temperature : - 30°C to + 85 °C (100 °C at peak)
CONSTRUCTION
Low noise cable
24 x .05 mm stranded copper ∅ = .28 mm nominal Polyethylene insulation ∅ = .70 ± .05mm Semi-conductive layer ∅ = .73mm nominal .07 mm copper braid ∅ = 1mm nominal PVC jacket ∅ = 1.4mm nominal.
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 022 595
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 55 -
Temporary myocard pacing wire
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 56 -
Filotex®
STUDY 060517
Temporary myocard pacing wire
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes
Electrical performances r DC resistance : ≤ 16 Ω/m r Insulation resistance : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC
CONSTRUCTION 19 x 0.06 stranded stainless
steel 316L PE insulation ∅ = .65 ± .03mm
Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . r Pull-off force : 5 N to 15 N
PRODUCT REFERENCES FILOTEX Ref : ET 060 517
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent
is n
ot p
erm
itted
with
out p
rior
writ
ten
auth
oriz
atio
n. In
form
atio
n su
bjec
t to
chan
ge w
ithou
t not
ice.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 57 -
Filotex®
STUDY 132070
Temporary myocard pacing wire
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes
Electrical performances r DC resistance : ≤ 30 Ω/m r Insulation resistance : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC
CONSTRUCTION 19 x 0.044 stranded stainless
steel 316L ∅ = .22 ± .02mm PE insulation ∅ = .48 ±.02mm
Thermal performances r Operating temperature : - 50°C to + 200 °C Mechanical performances r Minimum bending radius : 5 x Overall diameter . r Pull-off force : 5 N to 15 N
PRODUCT REFERENCES FILOTEX Ref : ET 132 070
Pass
ing
on o
r co
pyin
g of
the
docu
men
t, us
e or
com
mun
icat
e of
its
cont
ent i
s no
t per
mitt
ed w
ithou
t prio
r w
ritte
n au
thor
izat
ion.
Info
rmat
ion
subj
ect t
o ch
ange
with
out n
otic
e.
140 – 146 rue E. Delacroix / BP 1 F – 91211 Draveil cedex – FRANCE
Tel : + 33 1 69 83 78 00 Fax : + 33 1 69 42 05 70
Issue 1 - November 2000
- 58 -
Filotex®
STUDY 132524
Temporary myocard pacing wire
Characteristics r Very flexible cable with an extremely good mechanical behaviour. r Withstands miscellaneous sterilisation processes.
Electrical performances r DC resistance of inner conductor : ≤ 50 Ω/m r DC resistance of outer conductor : ≤ 30 Ω/m r Insulation resistance of insulation : ≥ 100 MΩ.km r Insulation resistance of jacket : ≥ 100 MΩ.km r Dielectric strength : ≥ 1500 V DC
CONSTRUCTION 19 x .044 mm stranded stainless steel 316L ∅ = .22 ± .02 mm Polyethylene insulation ∅ = .40 ± .02 mm 0.044 mm stainless steel 316L helicoidal screen min. coverage 90 % ∅ = .49 ± .02 mm Polyethylene jacket ∅ = .75 ± .05mm
Thermal performances r Operating temperature : - 30°C to + 75°C
Mechanical performances r Minimum bending radius : 5 x Overall diameter
PRODUCT REFERENCES FILOTEX Ref : ET 132 524
Pass
ing
on o
r cop
ying
of t
he d
ocum
ent,
use
or c
omm
unic
ate
of it
s co
nten
t is
not p
erm
itte
d w
itho
ut p
rior
wri
tten
aut
hori
zati
on. I
nfor
mat
ion
subj
ect t
o ch
ange
wit
hout
not
ice.