Top Banner
A COMPLETE RANGE OF AIR DIAPHRAGM PUMPS www.tablapump.com CONGRATULATIONS ON PURCHASING YOUR NEW TABLA PUMP! IMPORTANT: Please read all the installation and safety information carefully before you start your new pump. Pump parts 2 Pump designation system 3 Parts list 4 G.A. drawing 5 Exploded view rubber 6 Exploded view teflon 7 Directions for disassembly & reassembly 8 TM D 50 POLYPROPYLENE (BOLTED)
12

A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

May 05, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

A COMPLETE RANGE OF AIR DIAPHRAGM PUMPSwww.tablapump.com

CONGRATULATIONS ON PURCHASING YOUR NEW TABLA PUMP!IMPORTANT: Please read all the installation and safety information carefully before you start your new pump.

Pump parts 2 Pump designation system 3Parts list 4G.A. drawing 5Exploded view rubber 6Exploded view teflon 7Directions for disassembly & reassembly 8

TM

D 50POLYPROPYLENE

(BOLTED)

Page 2: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

TM

www.pricepumps.co.inwww.tablapump.com

2

1. Air Chamber The air chamber is the chamber that houses the

air which powers the diaphragms.

2. Air Distribution System The air distribution system is the heart of

the pump. The air distribution system is the mechanism that shifts the pump in order to create suction and discharge strokes.

3. Lock Nut (Outer Diaphragm Piston) The outer diaphragm pistons provide a means

to connect the diaphragms to the reciprocating common shaft and to seal the liquid side from the air side of the diaphragm.

4. Holding plate (Inner Diaphragm Piston) The inner piston is located on the air side of the

pump and does not come into contact with the process fluid.

5. Check Valve Ball TABLA air-operated pumps use suction and

discharge check valves to produce directional flow of process fluid in the liquid chamber. The check valve balls seal and release on the check valve seats allowing for discharge and suction of process fluid to occur.

6. Check Valve Seat The removable seats provide the ball valves a site

to check.

7. Discharge Manifold Process fluid exits the pump from the discharge

port located on the discharge manifold at the top of the pump.

8. Liquid Chamber The liquid chamber is filled with the process fluid

during the suction stroke and is emptied during

the discharge stroke. It is separated from the compressed air by the diaphragms.

9. Diaphragm The diaphragm membrane provides for separation

of the process fluid and the compressed air power source. To perform adequately, diaphragms should be of sufficient thickness and of appropriate material to prevent degradation or permeation in specific process fluid applications. TABLA offers a variety of diaphragm materials for your specific application requirements.

10. Inlet Manifold Process fluid enters the pump from the intake

port located on the inlet manifold at the bottom of the pump.

The TABLA PumpAir Operated Diaphragm Pump

1

32

10

4

9

5

8

7

6

Page 3: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

www.pricepumps.co.inwww.tablapump.com

TMThe TABLA PumpAir Operated Diaphragm Pump Pump Designation System

1AIR DISTRIBUTION SYSTEM

2 LIQUID PORT SIZE

3 WETTED PARTS 7,8

DIAPHRAGMS, VALVE BALLS

9 VALVE SEATS 11 CONNECTIONS

D Dura valve 40 40mm / 1 1/2” S Stainless Steel SN Santoprene™ (balls only)

S Stainless Steel N NPT

4 AIR CHAMBERS10

O-RING12 BOLTED

(OR CLAMPED)

A Aluminium TF TeflonB

Bolted

5 CENTER BLOCK

PPolypropylene (carbon-filled)

6 AIR VALVE

P Polypropylene

X / XX / XXXX / XX / XX / XXX / X / X1 2 3 4 5 6 7 8 9 10 11

1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT

SIZE 3 WETTED PARTS7,8

DIAPHRAGMS & VALVE BALLS 9 VALVE SEATS 11 CONNECTIONS

D Dura valve 15 15mm / 1/2” A Aluminium BN Buna - N / Nitrile A Aluminium N NPT

L Legacy valve 25 25mm / 1” S Stainless Steel ND Nordel / EPDM P Polypropylene B BSP

40 40mm / 1 1/2” P Polypropylene NE Neoprene S Stainless Steel 12 BOLTED(OR CLAMPED)

50 50mm / 2” K Kynar® / PVDF PU Polyurethane K Kynar® / PVDF B Bolted

80 80mm / 3” 4 AIR CHAMBERS SNSantoprene™ (balls only)

C Cast IronC Clamped

A Aluminium TFPTFE (with NEO back-up)

BN Buna - N / Nitrile

PPolypropylene (carbon-filled)

VT Viton/ FKMNE Neoprene

5 CENTER BLOCK ND Nordel / EPDM

A Aluminium VT Viton

PPolypropylene (carbon-filled)

SP Santoprene

6 AIR VALVE 10 O-RING

A Aluminium BN Buna - N / Nitrile

NE Neoprene

ND Nordel / EPDM

VT Viton

TF Teflon

12

D / 40 / SAPP / SN / TF / STF / N / B1 2 3 4 5 6 7 8 9 10 11 12

3

Page 4: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

Par

ts L

ist

SR.NO DISCRIPTION QUANTITY RUBBER FITTED TEFLON FITTED

PUMP OUTER PARTS

1 Liquid chamber 2 nos 50-5100-20 50-5100-20

2 Inlet manifold 1 nos 50-5300-20 50-5300-20

3 Outlet manifold 1 nos 50-5200-20 50-5200-20

4 Valve balls 4 nos 50-1080-51 50-1080-55

5 Valve seat 4 nos 50-1120-20 50-1120-20

6 Ball cage 4 nos 50-5701-20 50-5701-20

7 Seat ‘O’ ring big 4 nos 50-1203-51 50-1203-53

8 Seat ‘O’ ring small 4 nos 50-1204-51 50-1204-53

9 Inner diaphragm plate 2 nos 50-4501-01 50-4501-01

10 Outer diaphragm plate 2 nos 50-4600-20 50-4601-20

11 Diaphragm 2 nos 50-1010-51 50-1010-55

12 Back up diaphragm 2 nos N/A 50-1060-51

AIR CENTER PARTS

13 Centerh block 1 nos 50-3110-23 50-3110-23

14 Center block “o” ring 2 nos 40-1300-51 50-1300-51

15 Main shaft 1 nos 50-3810-59 50-3811-59

16 Main shaft buffer 2 nos 50-6700-51 50-6700-51

17 Air chamber gasket 2 nos 50-3210-60 50-3210-60

18 Air chamber 2 nos 50-3620-23 50-3620-23

19 Pilot bush ring 5 nos 40-3411-07 50-3411-07

20 Pilot bushing “o” ring 6 nos 40-1312-51 50-1312-51

21 Pilot bushing ring 2 nos 40-3412-07 50-3412-07

22 Pilot shaft 1 nos 40-3410-03 50-3410-03

23 Air valve body 1 nos 50-3710-23 50-3710-23

24 Air valve 1 nos 50-2010-01 50-2010-01

25 Piston “o” ring 3 nos 50-1310-51 50-1310-51

26 Piston ring 3 nos 50-1311-64 50-1311-64

27 Air valve end cap with guide 2 nos 50-2310-63 50-2310-63

28 End cap ‘o’ ring 2 nos 50-1315-51 50-1315-51

29 Snap ring 2 nos 50-2410-61 50-2410-61

30 Air valve w/o guide 1 n os 50-2510-23 50-2510-23

31 Air valve cover gasket 1 nos 50-3212-60 50-3212-60

32 Air valve gasket 1 nos 50-3211-60 50-3211-60

ACCESSORIES

33 Muffler 1 nos 50-3500-23 50-3500-23

34 Mounting pads 4 nos 50-8100-51 50-8100-51

35 Air nipple 1 nos 50-8200-07 50-8200-07

HARDWARE SET 50-6621-03 50-6621-03

36 Air cover bolts(5 / 16” X 1 1/4” SS, FT)

10 nos 40-6353-03 40-6353-03

37 Chamber bolts(3 / 8” X 100, SS, HT)

4 nos 80-6108-03 80-6108-03

38 Chamber bolts LONG(3 / 8” X 100 MM.SS.HT)

12 nos 80-6108-03 80-6108-03

39 Suction discharge bolts(1/2” X 2” SS- 304 FT)

16 nos 50-6350-03 50-6350-03

40 Air valve holding bolts(1 / 4” X 4” MS,HT)

6 nos 40-6300-61 40-6300-61

MATERIAL CODE

Polyurethane 50

Buna 52

Neoprene 51

Sentoprene 58

Hytrel 56

Teflon 55

PFA 22

Stainless steel 3

Cast iron 2

Brass 7

Viton 53

PVDF 21

Aluminum 1

Polyproplyene 20

Glass filled PP 23

EN-24 59

Non asbestos 60

MS 61

Hylem 62

HDPE 63

Silicon 64

MOC Neoprene Buna

Diaphragm 50-1010-55 50-1010-52

Balls 50-1080-55 50-1080-52

Tee o” ring N/A N/A

Seat o ring 50-1203-53 50-1203-52

Pump model 50-1103 50-1106

Page 5: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

www.pricepumps.co.inwww.tablapump.com

TM

G. A. drawing without mounting pad and flange

D 50 Polypropylene Bolted

5

Page 6: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

TM

www.pricepumps.co.inwww.tablapump.com

Exploded view- RUBBER fittedD 50 Polypropylene Bolted

1

2

4

34

3 39

58

6

7910 12

36

37

35

DETAIL - A

A

22 20 19 21

1817

15

33

1314

16

DETAIL - B

2825

26

B

B

38

Mumbai - 400 028. Tel. : 24453501 Fax. : 022 4440588 E-Mail :[email protected] :8, Gr. Flr.Hind Service Industrial Estate, Off Veer Savarkar Marg, Shivaji Park,

Factory : Plot No. 743, Phase II, G.I.D.C. Gundlav - 396 035, Dist. Valsad, PRICE PUMPSPVT. LTD. Gujarat State. Telefax : (02632) 236379, E-Mail :[email protected]

6

Page 7: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

www.pricepumps.co.inwww.tablapump.com

TMExploded view- TEFLON fittedD 50 Polypropylene Bolted

7

1

2

4

34

3 39

58

6

7910 11 12

36

37

35

DETAIL - A

A

22 20 19 21

1817

15

33

1314

16

DETAIL - B

2825

26

B

B

38

Mumbai - 400 028. Tel. : 24453501 Fax. : 022 4440588 E-Mail :[email protected] :8, Gr. Flr.Hind Service Industrial Estate, Off Veer Savarkar Marg, Shivaji Park,

Factory : Plot No. 743, Phase II, G.I.D.C. Gundlav - 396 035, Dist. Valsad, PRICE PUMPSPVT. LTD. Gujarat State. Telefax : (02632) 236379, E-Mail :[email protected]

Page 8: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

TM

www.pricepumps.co.inwww.tablapump.com

Lift away the discharge manifold to expose the valve balls and seats.

Remove the discharge valve balls, O-rings and seats (Fig 4) from the liquid chambers and inspect for nicks, gouges, chemical attack or abrasive wear. Replace worn parts with genuine TABLA parts for reliable performance.

Remove the discharge valve balls, O-rings and seats (Fig 7) from the liquid chambers and inspect for nicks, gouges, chemical attack or abrasive wear. Replace worn parts with genuine TABLA parts for reliable performance.

Before starting disassembly, mark a line from each liquid chamber to its corresponding air chamber. This line will assist in proper alignment during reassembly.

Utilizing a wrench, remove the bolts that fasten the discharge manifold to the liquid chambers.

Remove the bolts which fasten the suction manifold to the liquid chambers.

DISASSEMBLY

Lift suction manifold from liquid chambers and centre section to expose intake valve balls and seat. Inspect ball cage area of liquid chamber for excessive wear and damage.

Directions For Disassembly & Reassembly D 50 Polypropylene Bolted

CAUTION: Before any maintenance or repair is attempted, the compressed air line to the pump should be disconnected and all air pressure allowed to bleed from the pump. Disconnect all intake, discharge, and air lines. Drain the pump by turning it upside down and allowing any fluid to flow into a suitable container. Be aware of any hazardous effects of contact with your process fluid.

TOOLS REQUIRED:• Wrench• Allen Wrench• Adjustable Wrench• Adjustable Spanner• Vise equipped with soft jaws (such as plywood, plastic or other suitable material)

8

STEP 1

STEP 2

STEP 3

STEP 4

STEP 5

STEP 6

STEP 7 a

6

Page 9: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

www.pricepumps.co.inwww.tablapump.com

TM

9

STEP 8

STEP 9

STEP 11

Remove one set of bolts, which secure one liquid chamber to the center section.

STEP 13

STEP 10

Lift liquid chamber away from center section to expose diaphragm and lock nut (outer piston).

Normally inlet and discharge manifolds should not be disassembled during regular pump maintenance. Should this be necessary, completely remove clamp bands and inspect O-rings for nicks, cuts and chemical attack.

Using an adjustable wrench, or by rotating the diaphragm by hand, remove the diaphragm assembly.

NOTE: Due to varying torque values, one of the following two situations may occur:

1) The lock nut (outer piston), diaphragm and holding plate (inner piston) remain attached to the shaft and the entire assembly can be removed from the center section (Fig 12).

2) The lock nut (outer piston), diaphragm and holding plate (inner piston) separate from the shaft which remains connected to the opposite side diaphragm assembly (Fig 13). Repeat disassembly instructions for the opposite liquid chamber. Inspect diaphragm assembly and shaft for signs of wear or chemical attack. Replace all worn parts with genuine TABLA parts for reliable performance.

To remove diaphragm assembly from shaft, secure shaft with soft jaws (a vise fitted with plywood or other suitable material) to ensure shaft is not nicked, scratched, or gouged. Using an adjustable wrench or by hand, remove diaphragm assembly from shaft. Inspect all parts for wear and replace with genuine TABLA parts if necessary.

REASSEMBLY

STEP 12

Upon performing applicable maintenance to the air distribution system, the pump can now be reassembled. Please refer to the disassembly instructions for photos and parts placement. To reassemble the pump, follow the disassembly instructions in reverse order. The air distribution system needs to be assembled first, then the diaphragms and finally the wetted parts. Please find the applicable torque specifications on this page. The following tips will assist in the assembly process.• Clean the inside of the center section shaft bushing to

ensure no damage is done to new seals.• Stainless bolts should be lubed to reduce the

possibility of seizing during tightening.• Ensure proper alignment on the sealing surfaces of

intake and discharge manifolds.• Liquid chambers are easier to attach when the

diaphragm is inverted. Prior to attaching the second water chamber, push diaphragm assembly so that it is as close as possible to the center section.

• PVDF pumps require Teflon® gasket kits for improved sealing. Gasket kits may be installed on other pumps where sealing is an issue.

MAXIMUM TORQUE SPECIFICATIONS

DESCRIPTION OF PART PLASTIC PUMPS

AIR VALVE 3.4m-N[30in.-lbs.]

LOCK NUT (OUTER PISTON) 51.5m-N[38ft.-lbs.]

SMALL CLAMP BAND 9.6m-N[85in.-lbs.]

NUT - BOLTS (Rubber Diaphragm) 18.6m-N[165in.-lbs.]

NUT - BOLTS (Teflon Diaphragm) 18.6m-N[165in.-lbs.]

Page 10: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

TM

www.pricepumps.co.inwww.tablapump.com

Directions For Disassembly & Reassembly Air Distribution systemD 50 Polypropylene Bolted

Now check the centre block i.e. air valve with air cover Take out main shaft, replace If worn out or scored. Check shaft block bush ‘O’ rings, replace If worn out.

Remove the piston circlips, check piston block gasket and piston block cover.

Remove pilot shaft by unscrewing two nylock nuts if found damage replace them.

Remove piston block cap by help and holding bolts. Check the ‘O’ rings. Replace if worn out or damaged.

Remove the locknuts (outer piston) with the help of a Bench wice.

Remove the diaphragm & lock nut If diaphragm are damaged replace them (always replace both the diaphragm).

Remove the piston block from the shaft block by opening the 4 holding bolts.

DISASSEMBLY

TOOLS REQUIRED:• Adjustable Spanner• 1⁄4” Spanner• 5⁄16” Spanner• Circlip Plyer• Vise equipped with soft jaws (such as plywood, plastic or other suitable material)

10

STEP 1

STEP 2

STEP 3

STEP 4

STEP 5

STEP 6

STEP 7

Page 11: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

www.pricepumps.co.inwww.tablapump.com

TM

STEP 12

Check the air covers and shaft block gaskets. If found damaged, replace them.

Remove the pilot bushes. Check the ‘O’ rings. Replace if worn out or damaged.

Pilot bushes with rings and ‘O’ rings.

STEP 9

Remove air cover if required. Change gasket if Required.

Remove the piston. Check Piston rings. Clean the piston with solvent.

ASSEMBLY

For assembly, follow the reverse procedure.

11

STEP 8

STEP 10

STEP 11

Page 12: A COMPLETE RANGE OF AIR DIAPHRAGM … · 2020. 11. 21. · The TABLA Pump TM Air Operated Diaphragm Pump Pump Designation System 1 AIR DISTRIBUTION SYSTEM 2 LIQUID PORT SIZE 3 WETTED

ww

w.s

ixof

usde

sign

.com

AVAILABLE MATERIALS OF CONSTRUCTION - PUMPSSuction/discharge size 1/2” (15mm) 1”(25mm) 11/2”(40mm) 2”(50mm) 3”(75mm)

B = Bolted C = Clamped B C B C B C B C B C

Polypropylene (PP) 3 3 3 3 3 3 3 3

Polyvinylidene Fluoride (PVDF) 3 3 3 3 3 3 3 3

Stainless Steel (SS) 3 3 3 3 3

Aluminium (AL) 3 3 3 3 3

Cast Iron (CI) 3 3 3 3 3

Please consult us for your requirements for Hastelloy C, Alloy 20 etc.

A COMPLETE RANGE OF AIR DIAPHRAGM PUMPS

ISO 9001 : 2008

ISO 14001 : 2004

www.tablapump.com

T8585-3

TM