A COMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor: Prof. Bruce Mellado Thanks to: B. Mellado, E. Haddad, H. Jivan, C. Pelwan, G. Peters, iThemba LABS Gauteng team 1
18

A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

Dec 18, 2015

Download

Documents

Jasmine Murphy
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

1

A COMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE

ATLAS DETECTOR

Shell-may Liao

Supervisor: Prof. Bruce Mellado

Thanks to: B. Mellado, E. Haddad, H. Jivan, C. Pelwan, G. Peters, iThemba LABS Gauteng team

Page 2: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

2

OUTLINE

Introduction Scintillation mechanism SRIM and TRIM simulations Sample preparation Radiation process Transmission spectroscopy Results and analysis Conclusion

Page 3: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

3

INTRODUCTION

Main problem encountered by scintillators

Scintillators exhibit luminescence when excited by ionizing radiation

PVT based scintillators: EJ 200, EJ 208, EJ 260

Experimental procedure sample dimensions: 500μm x 500μm x 350 μm

Page 4: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

4

SCINTILLATION MECHANISM

Common feature in plastic scintillator = benzene ring

Delocalized electrons are prone to excitation

Electronic levels of a PVT molecule

PVT base is doped with flours

Fluors absorb the base scintillation and emit at longer wavelengths

Page 5: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

5

SRIM SIMULATIONS

About SRIM

Stopping Range of 6MeV protons in PVT

Stopping range = 474.17 μm

Page 6: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

6

TRIM SIMULATIONS

Transport of 6MeV protons in PVT

Average energy of transmitted protons = 2.8MeV

Thus energy lost by 6MeV protons = 3.2MeV

Page 7: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

7

SAMPLE PREPARATION Employed metallographic techniques:

• Documentation• 20 cm x 2 cm x

1cm• Sectioning and

cutting• Mounting• Rough Polishing• Final polishing

Polished samples range:

300 μm – 380 μm

Page 8: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

8

RADIATION PROCESS

Tandem accelerator of iThemba LABS Gauteng

Exposure doses:• 80 MGy• 25 MGy• 8 MGy• 0.8 MGy

Page 9: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

9

RADIATION PROCESS

Page 10: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

10

TRANSMISSION SPECTROSCOPY

Why transmission spectroscopy?

Dual beam spectrometer

Spectra recorded as percentage of light transmission through air

Page 11: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

11

TRANSMISSION SPECTROSCOPY

Page 12: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

12

UNIRRADIATED TRANSMISSION DATA

EJ 200 – 85.7%

EJ 208 – 83.2%

EJ 260 – 80.8%

Page 13: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

13

EJ 208 & EJ 260 TRANSMISSION PLOTS

Page 14: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

14

TRANSMISSION DATA

Page 15: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

15

EJ 208 TRANSMISSION PLOT (ANNEALING ID)

Page 16: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

16

EJ 200 TRANSMISSION PLOT (ANNEALING ID)

Page 17: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

17

CONCLUSION Radiation exposure = decrease in light transmission in all

grades

Increase in dose = decrease in transmission

Samples undergo annealing

Possible formation of free radicals (EPR)

Raman and light yield studies were done by Ms. Harshna Jivan

EJ 208 exhibits the best light transmission properties Lowest decrease in % transmission for most doses Large amount of healing in short period of time.

Page 18: A C OMPARATIVE STUDY OF THE RADIATION HARDNESS OF PLASTIC SCINTILLATORS FOR THE UPGRADE OF THE TILE CALORIMETER OF THE ATLAS DETECTOR Shell-may Liao Supervisor:

18

According to Markley et al, “A radiation hard plastic scintillator can be defined as a

scintillator that does not exhibit a large decrease in light yield output when exposed to ionizing radiation and which can recover a

substantial amount of its light output in a short time after being irradiated”.