Page 1: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

A Brief History ofMobile Home Construction

Rich CourtneyWeatherization Program Specialist

Page 2: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Early mobile home

Page 3: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

“It takes a sense of humor”

Page 4: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Three Decker Heated Floor

1948 Liberty

“Comfort Conditioning”

Page 5: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

1949

Prairie Schooner

Manufacture claims home is 10o cooler

Pulling a Prairie Schooner trailer saves between 10 to 25 gallons on long hops

Page 6: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

“Fully

Insulated”

“Johns-Manville

Floor Insulation”

1952“Happy Home”

“Separate Shower & Toilet”

“Water Heater”

“Oil or Butane Heat Optional”

Page 7: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Mobile Home with a “Tip Out”

Page 8: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

1975 Flamingo “Double Wide”

Page 9: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.
Page 10: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Manufactures Certificate

Page 11: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.
Page 12: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.
Page 13: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Pre 1976 Wall Stud size

Page 14: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Locate and inspect for wiring type, safety and power cable entrance

Page 15: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Water Heater Compartment

• See any problems?• Open controls• Exposed wiring• Flammable foam

insulation close to possible electrical hazards

• PVC discharge pipe• More?

Page 16: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

General ConstructionFeatures• Roof Assembly with Ceiling• Walls, Fixtures, Appliances

and Wiring• Flooring w/Finished Floor

Covering• 2x6 Framing• Main Ductwork• Insulation• Bellyboard• Main I-beams/

Outriggers/Cross Supports• Axles/Hitch

• Illustration courtesy of John Krigger

Page 17: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Primary Window TypesA. JalousieB. Horizontal SliderC. AwningD. Vertical Slider

• Illustration courtesy of John Krigger

Page 18: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Single-Wide and Double-WideFeatures

• Details showing “tie-downs”

• Foundation Support Piers

• Illustration courtesy of John Krigger

• “Marriage Line”

Page 19: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Crossover Duct on a Double-wide

• A crossover duct connects two complete duct systems. Each supplying conditioned air to each side of the dwelling.

• Note “Marriage Line”

• Illustration courtesy of John Krigger

Page 20: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Floor joist configuration

• Longitudinal or lengthwise floor joists

• Perpendicular or Crosswise floor joists

• Illustration courtesy of John Krigger

Page 21: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Forced Air Furnace Systems

• Furnaces are typically “down flow” heating units. The furnace connects to the main trunk line of the duct system located in the floor.

• Illustration courtesy of John Krigger

Page 22: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Location of the main trunk line depends on the floor joist

configuration

• Illustration courtesy of John Krigger

Page 23: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Use the information to help direct Weatherization work

Page 24: A Brief History of Mobile Home Construction Rich Courtney Weatherization Program Specialist.

Relax at the end of the day after a job well done