(e)PIT 696 694 692 690 686 684 682 680 678 676 674 672 670 668 666 664 662 660 658 698 700 702 704 706 708 710 1 2 3 4 5 12345 TGSI 1 2 3 4 5 TGSI Service01 TOILET04 TOILET03 EDB01 TOILET02 TOILET01 STORAGE CANTEEN02 DRESSING ROOM01 LIFT1 LIFT LOBBY01 FEMALE TOILET01 RL41.850 RL41.850 MEDICAL ROOM01 REFEREE'S ROOM RL41.850 RL41.850 RL41.850 RL41.850 DRESSING ROOM02 RL41.850 OFFICE01 RL41.850 RL41.850 RL41.850 DRESSING ROOM04 RL41.850 DRESSING ROOM03 RL41.850 LIFTLOBBY02 MALE TOILET01 CU CU RL41.850 RL41.850 LIFT MACHINE LIFT1 CANTEEN01 RL41.850 12345 TGSI 1 2 3 4 5 TGSI Service03 EDB02 MECH02 Service04 CU Service02 MECH01 CLEANER 01 GUT03 GUT03 ACCESS TOILET01 RL41.850 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 DP01 01 05 04 03 06 07 15 16 17 18 20 19 21 08 09 10 11 12 14 13 02 27 22 23 24 25 29 26 C F B E D G A TGSI TGSI TGSI TGSI RL44.500 RL42.990 RL43.493 RL43.996 Ramp2Leg1 1:20RampUp Ramp2Leg2 1:20RampUp Ramp2Leg3 1:20RampUp TGSI TGSI TGSI TGSI RL42.990 RL41.500 RL41.997 RL42.494 Ramp1Leg1 1:20RampUp Ramp1Leg2 1:20RampUp Ramp1Leg3 1:20RampUp TGSI TGSI TGSI TGSI 1 2 3 4 5 6 7 8 9 RL41.500 RL42.990 TGSI TGSI TGSI TGSI LOADING ZONE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PARKING RL44.500 1 2 3 4 5 6 7 8 9 RL42.990 RL44.500 1 2 3 4 5 6 7 8 TGSI RL41.850 RL42.890 1 2 3 4 5 TGSI TGSI MEDICAL ROOM02 MULTIPURPOSEHALL RL43.090 RL44.500 RL43.090 FIRSTFLOORGALLERYABOVE BINSTORE RL43.090 RECEPTIONAREA RETAININGWALL TRAININGKITCHEN RL43.090 CORRIDOR VOIDABOVE RL44.600 awningabove washbay 1 2 3 4 5 6 7 8 9 TGSI STORE 06 ACTIVITYROOM01 MALE TOILET02 FEMALE TOILET02 AMB. AMB. ACCESS TOILET02 LIFT2 DP01 DP02 DP01 DP01 DP01 DP01 DP01 DP01 DP01 Setout Setout Fall Fall 4000 2060 Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall Fall 1400 4000 3000 1:40 1:46 1:30 1:40 6960 1:40 RL41.750 RL41.850 RL41.750 RL41.840 2060 1:30 FEN01 FEN01 FEN01 FEN01 FEN01 8000 3000 CROSSING SWP SWP SWP SWP Conc B RL 42.890 EXISTING BUILDING RL 42.320 RL 42.300 RL 41.500 RL 42.000 RL 42.000 RL 42.000 Stage 2 Car park RL 42.890 RL 43.400 ex RL 44.500 ex RL 44.540 R: 45,000 Electronic scoreboard. read in conjunction with electrical Eningeers drawings. PLAYGROUND Under separate contract RL 41.500 RL 42.290 RL 41.000 RL 41.500 ex RL 40.430 ex RL 40.110 5000 64000 5000 5500 5500 100000 3000 7410 3000 8000 3000 ex RL 40.650 ex RL 40.940 ex RL 40.950 ex RL 41.380 ex RL 41.640 ex RL 41.880 RL 41.500 RL 42.990 RL 44.500 Hydraulic Cricket Wicket to manufactures details. Extent or concrete slab under cricket pitch shown hatched . extent of timber decking shown hatched. refer also to engineer's documentation 1 / 2 A-007 A-100 A-101 A-109 A-008 1 / 2 1 A-007 RL 42.810 RL 42.590 RL 43.400 RL 43.400 RL 43.970 RL 44.200 RL 43.550 STAGE 2 Carpark King Georges Road Percival Road Cambridge Street Existing carpark 2345 STAGE 2 BUILDING SETOUT DIMENSION STAGE 2 BUILDING SETOUT DIMENSION SETOUT POINT 81375 STAGE 1 Refer to Stage 1 Documentation 90000 3000 RL 42.300 RL 41.000 RL 41.950 RL 41.090 RL 41.900 RL 41.810 RL 41.900 RL 41.900 2360 2380 220 2370 4000 RL 40.820 RL 41.900 42.300 3000 43000 Ramp Up Line of FEN02 Line of Retaining Wall Part of fence removable for access (FEN02) 5280 Line of FEN02 Line of FEN02 Line of FEN02 Line of FEN02 DSB 22410 24150 + RL 41.500 + RL 41.500 + RL 41.500 + RL 40.820 Concrete Finish To Ramp Colour To Schedule. Conc. Conc. Conc. Artificial Turf Install Expansion Joint To Junction Between Concrete Ramp And Artificial Field. PRELIMINARY CONSTRUCTION CERTIFICATE Ground Floor Plan Penshurst Sporting Hub - Stage 2 Penshurst Park, King Georges Road, Penshurst GEORGES RIVER COUNCIL Date REVISION/ISSUE ISSUE All dimensions are in millimetres unless stated otherwise. All architectural, drawings are to be read in conjunction with the relevant consultant documents. All dimensions and levels are to be checked and verified on site prior to the commencement of work, shop drawings or fabrication of any components. Refer all discrepancies to the Architect for determination. Drawings are not to be scaled, use only figured dimensions. This drawing is copyright and must not be retained, copied or used without the permission of BKA Architecture. This document has been prepared for and on behalf of the clients noted on the drawing, BKA Architecture's responsibility is to the clients only and not to any third party who may rely on these documents. PROJECT CLIENT DRAWING DRAWING No. REV NORTH ADDRESS PROJECT # DATE SCALE @ A1 DRAWN CHECKED CLIENT For Construction - 16/12/19 T E: W: S Y D N E Y T N E W C A S T L E T B Y R O N B A Y Issue to Client for TENDER Submssion. 13/9/19 1 2 03/10/19 Addenda Issue. Refer to revision notes on drawing sheet. 3 31/10/19 Addenda Issue. Refer to revision notes on drawing. 4 10/12/19 For consultant co-ordination 5 16/12/19 Issue for Construction