OWNER ARCHITECT RCL ARCHITECTURE, L.L.C. 900 W. CAUSEWAY APPROACH MANDEVILLE, LA 70471 PHONE: 985-727-4440 FAX: 985-727-4447 PROJECT TEAM CITY of NEW ORLEANS OFFICE of FACILITIES, INFRASTRUCTURE AND COMMUNITY DEVELOPMENT CAPITAL PROJECTS ADMINISTRATION / PDU DELIVERY UNIT 1300 PERDIDO STREET SUITE 6E15 NEW ORLEANS, LOUISIANA 70112 PHONE: 504-658-8666 FAX: 504-658-8652 MEP ENGINEERS INFINITY ENGINEERING 2626 CANAL BOULEVARD NEW ORLEANS, LOUISIANA 70179 PHONE: 504-304-0548 FAX: 504-355-0265 A0.00 COVER SHEET NORTH A6.03 7 A6.03 7 A6.03 7 A6.03 7 A6.03 7 A6.03 7 A6.03 7 K 132 129 CS A 1 PLAN & ACTUAL NORTH ARROW LEVEL POINT DATUM LINE NEW CONST. COLUMN LINE REFERENCE WINDOW TYPE ROOM NUMBER DOOR NUMBER PARTITION TYPE REVISION NUMBER EXTERIOR ELEVATION INTERIOR ELEVATIONS PROPERTY LINE LARGE SCALE REFERENCE SECTION MARK DETAIL REFERENCE DETAIL NO. BUILDING OR WALL SECTION SHEET NO. DETAIL NO. DETAIL DRAWN IS OPPOSITE HAND OF REFERENCE LOCATION DETAIL DRAWN IS SIMILAR TO REFERENCE LOCATION CENTER LINE BREAK LINE ELEVATION NO. SHEET NO. SYMBOL LEGEND A0.00 2 N.T.S. VICINITY MAP A0.00 1 N.T.S. 1 DASHED LINE SHEET NO. DETAIL NO. SHEET NO. SIMILAR OPP. HAND SITE LOCATION CITY of NEW ORLEANS ST. BERNARD CENTER LOCKER ROOM RENOVATIONS 1500 LAFRENIERE STREET NEW ORLEANS, LOUISIANA 70122 PROJECT NO. MK14 -1129 N INDEX OF DRAWINGS COVER SHEET SHEET# A0.00 DESCRIPTION SHEET# A1.01 DEMOLITION FLOOR PLAN DESCRIPTION A3.01 FINISH SCHEDULE & SECTIONS A1.02 RENOVATION FLOOR PLAN Sheet Number: Copyright 2014 Date Issued: Revisions: 01-09-15 Project Number: RCLC TLM Drawn By: Checked By: - ST. BERNARD CENTER 21436 NEW ORLEANS, LOUISIANA 70122 1500 LAFRENIERE STREET 900 W. Causeway Approach Mandeville, LA 70471 985-727-4440 Fax: 985-727-4467 829 Baronne St. New Orleans, LA 70113 504-837-7346 RCL ARCHITECTURE, L.L.C. This drawing and design is the exclusive property of Richard C. Lambert Consultants, LLC and may not be reproduced or used without authorization and written permission. 2014 LOCKER ROOM RENOVATIONS CITY of NEW ORLEANS P A U L F . D I M I T R I O S R E G I S T E R E D A R C H I T E C T S T A T E O F L O U I S I A N A R e g . N o . 6 9 3 1 Project Number: City of New Orleans MK14-1129 01-09-15 A5.01 INTERIOR ELEVATIONS A6.01 REFLECTED CEILING PLAN MECHANICAL NOTES & SCHEDULES M1.00 MECHANICAL FLOOR PLANS M2.00 MECHANICAL DETAILS M3.00 ELECTRICAL REFLECTED CEILING PLAN E1.00 ELECTRICAL POWER PLAN E1.01 PLUMBING NOTES P1.00 PLUMBING DEMOLITION PLANS P2.00 PLUMBING FLOOR PLANS P3.00 PLUMBING DETAILS P4.00 A5.02 INTERIOR ELEVATIONS
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
OWNER
ARCHITECT RCL ARCHITECTURE, L.L.C.
900 W. CAUSEWAY APPROACHMANDEVILLE, LA 70471
PHONE: 985-727-4440FAX: 985-727-4447
PROJECT TEAM
CITY of NEW ORLEANSOFFICE of FACILITIES, INFRASTRUCTURE AND COMMUNITY DEVELOPMENT
CAPITAL PROJECTS ADMINISTRATION / PDU DELIVERY UNIT1300 PERDIDO STREET
SUITE 6E15NEW ORLEANS, LOUISIANA 70112
PHONE: 504-658-8666FAX: 504-658-8652
MEP ENGINEERSINFINITY ENGINEERING
2626 CANAL BOULEVARDNEW ORLEANS, LOUISIANA 70179
PHONE: 504-304-0548FAX: 504-355-0265
A0.00
COVERSHEET
NORTH
A6.03
7
A6.03
7
A6.03
7
A6.03
7
A6.03
7
A6.03
7
A6.03
7
K
132
129
CS
A
1
PLAN & ACTUALNORTHARROW
LEVEL POINTDATUM LINE
NEW CONST.COLUMN LINEREFERENCE
WINDOW TYPE
ROOM NUMBER
DOOR NUMBER
PARTITIONTYPE
REVISIONNUMBER
EXTERIORELEVATION
INTERIORELEVATIONS
PROPERTY LINE
LARGE SCALEREFERENCE
SECTION MARK
DETAIL REFERENCE
DETAIL NO.
BUILDING OR WALLSECTION
SHEET NO.
DETAIL NO.
DETAIL DRAWN ISOPPOSITE HAND OFREFERENCE LOCATION
DETAIL DRAWN ISSIMILAR TOREFERENCE LOCATION
CENTER LINE
BREAK LINEELEVATION NO.SHEET NO.
SYMBOL LEGENDA0.00
2N.T.S.
VICINITY MAPA0.00
1N.T.S.
1
DASHED LINE
SHEET NO.
DETAIL NO.SHEET NO.
SIMILAR
OPP. HAND
SITE LOCATION
CITY of NEW ORLEANS
ST. BERNARD CENTER
LOCKER ROOM RENOVATIONS
1500 LAFRENIERE STREET
NEW ORLEANS, LOUISIANA 70122
PROJECT NO. MK14 -1129
N
INDEX OF DRAWINGS
COVER SHEET
SHEET#
A0.00
DESCRIPTION SHEET#
A1.01 DEMOLITION FLOOR PLAN
DESCRIPTION
A3.01 FINISH SCHEDULE & SECTIONSA1.02 RENOVATION FLOOR PLAN
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
01-09-15
Project Number:RCLC
TLMDrawn By:Checked By: -
ST. B
ERN
AR
D C
ENTE
R
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
INSTALL NEW SHOWER HEAD & FAUCET.RELOCATE SHOWER HEAD AND FAUCET SO THATSHOWER HEAD IS CENTERED BETWEEN SHOWERPARTITIONS. CONTRACTOR IS TO REPAIR CMUWALL AND PREP BLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL NEW HANDICAP SHOWER HEAD &HANDICAP FAUCET. RELOCATE SHOWER HEADAND FAUCET SO THAT SHOWER HEAD ISCENTERED BETWEEN SHOWER PARTITIONS.CONTRACTOR IS TO REPAIR CMU WALL AND PREPBLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL HANDICAP SHOWER SEAT(SEE SPECIFICATIONS)
INSTALL NEW SHOWER PARTITIONS INCLUDETOWEL HOOK ON DOOR (SEE SPECIFICATIONS)
INSTALL NEW LOCKERS (SEE SPECIFICATIONS)
INSTALL APPROX. 4" THK. x 17" WIDECONCRETE PAD FOR LOCKERS (V.I.F.)
INSTALL 12" WIDE X 8'-0" LONG BENCH(SEE SPECIFICATIONS)
INSTALL NEW SURFACE MOUNTEDWASTE DISPENSER (SEE SPECIFICATIONS)
CAP TOILET DRAIN
INSTALL 4" OR 8" X 8" X 8'-8" HIGH CMU WALL
PATCH CMU WALL W/ SIMILAR EXISTINGMATERIALS.
INSTALL GRATING LEVEL WITH FLOOR(SEE DETAIL 2/A3.01)(SEE SPECIFICATIONS)
INSTALL APPROX. 3 1/2" THICK CONCRETETOPPING (SEE DETAIL 1/A3.01)
INSTALL FLOOR GRATING (SEE DETAIL 1/A3.01)(SEE SPECIFICATIONS)
INSTALL MOISTURE RESISTANT ACOUSTICALCEILING TILE (SEE REFLECTED CEILING PLAN -SHEET A6.01) (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" METAL DOORINCLUDE HINGES, EXIT DEVICE, PULL HANDLE &PLATE, DOOR STOP, DOOR CLOSURE & MARBLETHRESHOLD (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" WOOD DOORINCLUDE HINGES, LOCK, PUSH PLATE, PULLHANDLE, DOOR STOP, KICKPLATES, DOORCLOSURE & MARBLE THRESHOLD (SEE SPECS.)
INSTALL NEW 3/4" PLAM VANITY KNEE PROTECTIONPANEL AS PER ADAAG
INSTALL HAND DRYER (SEE SPECIFICATIONS)
INSTALL 16 GA. ALUMINUM SHEET METAL PANEL(APPROX. 1'-8" X 20") TO COVER OPENINGBETWEEN LOCKERS. ATTACH TO LOCKERS WITHALUMINUM RIVETS @ 3" O.C.
INSTALL METAL STUD FURR DOWN WITH 1/2"MOISTURE RESISTANT GYP. BD. ON SIDES ANDBOTTOM. (SEE DETAIL 5/A5.01)
INSTALL NEW SHOWER HEAD & FAUCET.RELOCATE SHOWER HEAD AND FAUCET SO THATSHOWER HEAD IS CENTERED BETWEEN SHOWERPARTITIONS. CONTRACTOR IS TO REPAIR CMUWALL AND PREP BLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL NEW HANDICAP SHOWER HEAD &HANDICAP FAUCET. RELOCATE SHOWER HEADAND FAUCET SO THAT SHOWER HEAD ISCENTERED BETWEEN SHOWER PARTITIONS.CONTRACTOR IS TO REPAIR CMU WALL AND PREPBLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL HANDICAP SHOWER SEAT(SEE SPECIFICATIONS)
INSTALL NEW SHOWER PARTITIONS INCLUDETOWEL HOOK ON DOOR (SEE SPECIFICATIONS)
INSTALL NEW LOCKERS (SEE SPECIFICATIONS)
INSTALL APPROX. 4" THK. x 17" WIDECONCRETE PAD FOR LOCKERS (V.I.F.)
INSTALL 12" WIDE X 8'-0" LONG BENCH(SEE SPECIFICATIONS)
INSTALL NEW SURFACE MOUNTEDWASTE DISPENSER (SEE SPECIFICATIONS)
CAP TOILET DRAIN
INSTALL 4" OR 8" X 8" X 8'-8" HIGH CMU WALL
PATCH CMU WALL W/ SIMILAR EXISTINGMATERIALS.
INSTALL GRATING LEVEL WITH FLOOR(SEE DETAIL 2/A3.01)(SEE SPECIFICATIONS)
INSTALL APPROX. 3 1/2" THICK CONCRETETOPPING (SEE DETAIL 1/A3.01)
INSTALL FLOOR GRATING (SEE DETAIL 1/A3.01)(SEE SPECIFICATIONS)
INSTALL MOISTURE RESISTANT ACOUSTICALCEILING TILE (SEE REFLECTED CEILING PLAN -SHEET A6.01) (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" METAL DOORINCLUDE HINGES, EXIT DEVICE, PULL HANDLE &PLATE, DOOR STOP, DOOR CLOSURE & MARBLETHRESHOLD (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" WOOD DOORINCLUDE HINGES, LOCK, PUSH PLATE, PULLHANDLE, DOOR STOP, KICKPLATES, DOORCLOSURE & MARBLE THRESHOLD (SEE SPECS.)
INSTALL NEW 3/4" PLAM VANITY KNEE PROTECTIONPANEL AS PER ADAAG
INSTALL HAND DRYER (SEE SPECIFICATIONS)
INSTALL 16 GA. ALUMINUM SHEET METAL PANEL(APPROX. 1'-8" X 20") TO COVER OPENINGBETWEEN LOCKERS. ATTACH TO LOCKERS WITHALUMINUM RIVETS @ 3" O.C.
INSTALL METAL STUD FURR DOWN WITH 1/2"MOISTURE RESISTANT GYP. BD. ON SIDES ANDBOTTOM. (SEE DETAIL 5/A5.01)
1. CHECK & VERIFY ALL DIMENSIONS &CONDITIONS AT THE JOB SITE BEFORESTARTING THE WORK. NOTIFY GENERALCONTRACTOR AND THE ARCHITECT OF ANYDISCREPANCIES OR POTENTIAL CONFLICTSBEFORE PROCEEDING WITH THE WORK.
2. FIELD VERIFY ALL DIMENSIONS PRIOR TOFABRICATION OR INSTALLATION OF BUILDINGCOMPONENTS.
3. DIMENSIONS ARE FROM FACE OF CMU WALL,UON.
4. ALL OUTLETS AND SWITCHES MAY NOT BESHOWN. SEE ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION.
5. BUILDING COMPONENTS ARE SHOWN FORCOORDINATION PURPOSES ONLY.COORDINATE WITH OWNER AS TO MAKE,MODEL AND COLOR OF COMPONENTS.
6. REFER TO FINISH SCHEDULE FOR LISTING OFFINISHES.
7. WHERE SPECIFIC DETAILING IS NOT SHOWN,EXECUTE THE CONSTRUCTION IN A SOUND,WORKMANLIKE MANNER CONSISTENT WITHOTHER DETAILING SHOWN HERE.
INTERIOR ELEVATION NOTES:
R27
(3 PLACES) R14A R14B
17"
(PARTITION DOORS NOT SHOWN FOR CLARITY)
17"
17"
R35 (4 PLACES)
1'-1"
4'-6
"6"
BA
SE
3" B
ULL
NO
SE
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
01-09-15
Project Number:RCLC
TLMDrawn By:Checked By: -
ST. B
ERN
AR
D C
ENTE
R
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
LOC
KER
RO
OM
REN
OV
ATI
ON
S
CIT
Y o
f NEW
OR
LEA
NS
PAU
L F . D IMI TRI OS
REG
I S T ER E D A RC H I T ECT
ST
A
TE
O F L O U I SI A
NA
Re
g. N o . 6
93
1
Project Number:City of New Orleans
MK14-1129
01-09-15
WOMEN'S SWIM LOCKER INTERIOR ELEVATIONA5.02
1SCALE: 1/2" = 1'-0"
A5.02
INTERIORELEVATIONS
4'-6
"
5'-0"2'-9"2'-9"
5'-4"
2'-912"2'-8"2'-8"5'-0"
R1
RENOVATION NOTES:INSTALL NEW TOILET (SEE SPECIFICATIONS)
INSTALL NEW TOILET INCLUDING DRAIN &WATER LINES (SEE SPECIFICATIONS)
INSTALL NEW URINAL (SEE SPECIFICATIONS)
INSTALL NEW URINAL, RECONFIGURE DRAIN &WATER LINES (SEE SPECIFICATIONS)
INSTALL NEW TOILET PAPER DISPENSER(SEE SPECIFICATIONS)
INSTALL NEW SHOWER HEAD & FAUCET.RELOCATE SHOWER HEAD AND FAUCET SO THATSHOWER HEAD IS CENTERED BETWEEN SHOWERPARTITIONS. CONTRACTOR IS TO REPAIR CMUWALL AND PREP BLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL NEW HANDICAP SHOWER HEAD &HANDICAP FAUCET. RELOCATE SHOWER HEADAND FAUCET SO THAT SHOWER HEAD ISCENTERED BETWEEN SHOWER PARTITIONS.CONTRACTOR IS TO REPAIR CMU WALL AND PREPBLOCK TO RECEIVE CERAMIC TILE(SEE SPECIFICATIONS)
INSTALL HANDICAP SHOWER SEAT(SEE SPECIFICATIONS)
INSTALL NEW SHOWER PARTITIONS INCLUDETOWEL HOOK ON DOOR (SEE SPECIFICATIONS)
INSTALL NEW LOCKERS (SEE SPECIFICATIONS)
INSTALL APPROX. 4" THK. x 17" WIDECONCRETE PAD FOR LOCKERS (V.I.F.)
INSTALL 12" WIDE X 8'-0" LONG BENCH(SEE SPECIFICATIONS)
INSTALL NEW SURFACE MOUNTEDWASTE DISPENSER (SEE SPECIFICATIONS)
CAP TOILET DRAIN
INSTALL 4" OR 8" X 8" X 8'-8" HIGH CMU WALL
PATCH CMU WALL W/ SIMILAR EXISTINGMATERIALS.
INSTALL GRATING LEVEL WITH FLOOR(SEE DETAIL 2/A3.01)(SEE SPECIFICATIONS)
INSTALL APPROX. 3 1/2" THICK CONCRETETOPPING (SEE DETAIL 1/A3.01)
INSTALL FLOOR GRATING (SEE DETAIL 1/A3.01)(SEE SPECIFICATIONS)
INSTALL MOISTURE RESISTANT ACOUSTICALCEILING TILE (SEE REFLECTED CEILING PLAN -SHEET A6.01) (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" METAL DOORINCLUDE HINGES, EXIT DEVICE, PULL HANDLE &PLATE, DOOR STOP, DOOR CLOSURE & MARBLETHRESHOLD (SEE SPECIFICATIONS)
INSTALL NEW 1 3/4" THK. x 3'-0" x 7'-0" WOOD DOORINCLUDE HINGES, LOCK, PUSH PLATE, PULLHANDLE, DOOR STOP, KICKPLATES, DOORCLOSURE & MARBLE THRESHOLD (SEE SPECS.)
INSTALL NEW 3/4" PLAM VANITY KNEE PROTECTIONPANEL AS PER ADAAG
INSTALL HAND DRYER (SEE SPECIFICATIONS)
INSTALL 16 GA. ALUMINUM SHEET METAL PANEL(APPROX. 1'-8" X 20") TO COVER OPENINGBETWEEN LOCKERS. ATTACH TO LOCKERS WITHALUMINUM RIVETS @ 3" O.C.
INSTALL METAL STUD FURR DOWN WITH 1/2"MOISTURE RESISTANT GYP. BD. ON SIDES ANDBOTTOM. (SEE DETAIL 5/A5.01)
MEN'S AND WOMEN'S SWIM LOCKER INTERIOR ELEVATIONA5.02
4SCALE: 1/2" = 1'-0"
R19
R17
R28
R17R17
8'-0
"
18'-0"
6'-0
"4"
4" HIGHCONCRETE PAD
W/ CERAMIC BASE
MEN'S AND WOMEN'S SWIM LOCKER INTERIOR ELEVATIONA5.02
5SCALE: 1/2" = 1'-0"
R19
3'-6"
R17
R17
A5.015
R28
R34
8'-0
"
SIM.SIM.
2'-4" 2'-0"
1. CHECK & VERIFY ALL DIMENSIONS &CONDITIONS AT THE JOB SITE BEFORESTARTING THE WORK. NOTIFY GENERALCONTRACTOR AND THE ARCHITECT OF ANYDISCREPANCIES OR POTENTIAL CONFLICTSBEFORE PROCEEDING WITH THE WORK.
2. FIELD VERIFY ALL DIMENSIONS PRIOR TOFABRICATION OR INSTALLATION OF BUILDINGCOMPONENTS.
3. DIMENSIONS ARE FROM FACE OF CMU WALL,UON.
4. ALL OUTLETS AND SWITCHES MAY NOT BESHOWN. SEE ELECTRICAL DRAWINGS FORADDITIONAL INFORMATION.
5. BUILDING COMPONENTS ARE SHOWN FORCOORDINATION PURPOSES ONLY.COORDINATE WITH OWNER AS TO MAKE,MODEL AND COLOR OF COMPONENTS.
6. REFER TO FINISH SCHEDULE FOR LISTING OFFINISHES.
7. WHERE SPECIFIC DETAILING IS NOT SHOWN,EXECUTE THE CONSTRUCTION IN A SOUND,WORKMANLIKE MANNER CONSISTENT WITHOTHER DETAILING SHOWN HERE.
INTERIOR ELEVATION NOTES:
R27
(3 PLACES) R14A
R14B
R27 R27
R27
(PARTITION DOORS NOT SHOWN FOR CLARITY)
(PARTITION DOORS NOT SHOWN FOR CLARITY)
4'-6
"6"
BA
SE
3" B
ULL
NO
SE
4'-6
"6"
BA
SE
3" B
ULL
NO
SE
R35(4 PLACES)
2'-0"
R27
R22
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
01-09-15
Project Number:RCLC
TLMDrawn By:Checked By: -
ST. B
ERN
AR
D C
ENTE
R
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
LOC
KER
RO
OM
REN
OV
ATI
ON
S
CIT
Y o
f NEW
OR
LEA
NS
PAU
L F . D IMI TRI OS
REG
I S T ER E D A RC H I T ECT
ST
A
TE
O F L O U I SI A
NA
Re
g. N o . 6
93
1
Project Number:City of New Orleans
MK14-1129
01-09-15
A6.01
REFLECTEDCEILINGPLAN
WOMEN'SSWIM LOCKER
128
MEN'SSWIM LOCKER
125
WOMEN'S SWIM LOCKER REFLECTED CEILING PLANA6.01
2SCALE: 1/2" = 1'-0"
MEN'S SWIM LOCKER REFLECTED CEILING PLANA6.01
1SCALE: 1/2" = 1'-0"
R.C.P. SYMBOL LEGEND
WALL SLOT LIGHT FIXTURE
HVAC DIFFUSER
EXHAUST FAN
2' X 4' FLUORESCENT TROFFERACRYLIC LENS
2' X 2' FLUORESCENT TROFFERACRYLIC LENS
GYP. BD. FURR DOWN
A5.015
TYP.
A5.015
TYP.
1. CHECK & VERIFY ALL DIMENSIONS & CONDITIONS AT THE JOB SITE BEFORE STARTING THE WORK.NOTIFY GENERAL CONTRACTOR AND THE ARCHITECT OF ANY DISCREPANCIES OR POTENTIALCONFLICTS BEFORE PROCEEDING WITH THE WORK.
2. FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION OR INSTALLATION OF BUILDINGCOMPONENTS.
3. FIXTURES, GRILLES AND EQUIPMENT SHOWN ARE FOR COORDINATION PURPOSES ONLY. REFER TOTHE ELECTRICAL AND MECHANICAL DRAWINGS, MANUFACTURER'S PRODUCT DATA ANDSPECIFICATIONS FOR ACTUAL FIXTURE, GRILLE AND EQUIPMENT DESCRIPTIONS AND LOCATIONS.
4. WHERE SPECIFIC DETAILING IS NOT SHOWN, EXECUTE THE CONSTRUCTION IN A SOUND,WORKMANLIKE MANNER CONSISTENT WITH OTHER DETAILING SHOWN HERE.
5. REPLACE ALL EXISTING SPRINKLER HEADS WITH NEW CONCEALED TYPE SPRINKLER HEADS. COLORTO BE DETERMINED. RELOCATE HEADS TO BE IN CENTER OF CEILING TILE. COORDINATE SPRINKLERMODIFICATIONS WITH BUILDING MANAGER. REFER TO MECHANICAL DRAWINGS FOR SPECIFICS ONEXECUTION OF WORK & REQUIRED MATERIALS.
REFLECTED CEILING PLAN NOTES:
M1.00
MECHANICALNOTES &SCHEDULES
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
NOTES: 1. INSTALL FAN ABOVE CEILING SUSPENDED FROM STRUCTURE WITH SPRING TYPE VIBRATION ISOLATION, MIN DEFLECTION 3/4".2. PROVIDE FAN WITH INTEGRAL BACKDRAFT DAMPER.3. FAN SHALL BE SWITCHED WITH LIGHTS.4. PROVIDE DUCT TRANSITIONS AT INLET AND DISCHARGE OF FAN WITH FLEXIBLE CONNECTION AT EACH CONNECTION.5. PROVIDE EACH FAN WITH A SOLID STATE SPEED CONTROLLER TO BE INSTALLED ABOVE CEILING AT THE FAN.
EXHAUST FANS
ID BASIS FOR DESIGN CFM ESP SONES DRIVE DIMENSIONS WT(LBS) SERVESMOTOR DATA
POWER VOLTAGE PHASE RPM
EF-1 GREENHECK MODEL CSP-A390 300 0.25" 1.3 DIRECT 14"x12"x12"H 23 WOMEN'S LOCKER ROOM 150 W 115 1 1112
EF-2 GREENHECK MODEL CSP-A390 350 0.25" 2.0 DIRECT 14"X12"X12"H 36 MEN'S LOCKER ROOM 150 W 115 1 1255
GALVANIZED STEEL DUCT, 1ST NUMBER IS SIDE SHOWN (ININCHES)
ROUND FLEXIBLE DUCT, SIZE IN INCHES
THERMOSTAT
MANUAL VOLUME DAMPER
TURNING VANES, EXTENDED IN DIRECTION OF FLOW ANDLOCATED 2" ON CENTER
D
SUPPLY DIFFUSER, CFM AS NOTED
RET OR EXH GRILLE, CFM AS NOTED
LOUVER, SIZE AS INDICATED
NUMBERED NOTES
AIR HANDLING UNITAHU
CEILING GRILLECG
DOWNDN
EXHAUST AIREA
EXHAUST FANEF
EXISTING TO REMAINETR
EXISTINGEXIST
EXHAUSTEXH
FULL LOAD AMPSFLA
FEET PER MINUTEFPM
HORSEPOWERHP
KILOWATTKW
CUBIC FEET PER MINUTECFM
CEILING DIFFUSERCD
MANUAL VOLUME DAMPERMVD
NOISE CRITERIANC
OUTSIDE AIROA
LOUVERL
EXTERNAL STATIC PRESSUREESP
ELECTRICAL CONTRACTOREC
GENERAL CONTRACTORGC
MECHANICAL CONTRACTORMC
STATIC PRESSURESP
TYPICALTYP
RECTANGULAR TO ROUND DUCT TRANSITION
DUCT ELEVATION CHANGE, U=UP D=DOWN
DUCT TRANSITION
STANDARD 45° BRANCH, SUPPLY/RETURNWITH MANUAL VOLUME DAMPER
MOTORIZED DAMPER
DUCT ACCESS DOOR
SMOKE DETECTORSD
T
ABBREVIATIONS: DR - OPPOSED BLADE ALUMINUM DAMPERTR - SQUARE TO ROUND NECK TRANSITIONFD - FIRE DAMPER ASSEMBLY WITH RADIATION BLANKET
NOTES: 1. ALL DIFFUSERS, REGISTERS AND GRILLES ARE BASED ON TITUS MODELS
DIFFUSER AND GRILLE SCHEDULEID CFM NC OVERALL NECK MOUNTING MATERIAL DR TR FD DESCRIPTION
CD-A 150-200 25 24/24 8"Ø EXPOSED T-BAR ALUMINUM YES NO NO SQUARE CEILING DIFFUSER
CG-A 150-190 <20 24/24 12/12 EXPOSED T-BAR ALUMINUM NO NO NO PERFORATED CEILING GRILLE
CG-B 300-375 <20 24/24 22/22 EXPOSED T-BAR ALUMINUM NO NO NO EGGCRATE RTURN GRILLE FORT-BAR CEILING
2. PROVIDE INSULATED TRANSITION BOOT BETWEEN DUCT AND DIFFUSER/GRILLE NECK.
C. BOYERM. LEITZINGER
C. BOYERM. LEITZINGER
CONNECT TO EXISTING
END POINT OF DEMOLITION
ETR 18/14
TO ETRAHU-2
ETR 18/14
ETR 18/14
ETR
16/6 EX
H
20/5
LOUVER12/16 EXH
20/5
ETRSIDEWALLGRILLE
12/14
ETR
24/12
8"Ø
8"Ø
ETR 12"Ø
CD-A
CD-A
CD-A
4
9
6
1
2 150
5
1
28
7
150
EF-1
CG-A
7
100
3
CG-A
10/8
ETR
18/14H
OT D
UC
T
ETR
18/14C
OLD
DU
CT
CG-B
LOUVER12/16 EXH
ETRCEILINGGRILLE
ETR
18/14
ETR
16/6 EX
H
16/6 EXH
ETRSIDEWALLGRILLE
ETR
24/12
12/12
24/12
8"Ø
8"Ø
1
23
8
1 2
4
5
2
7
6
CD-A
CD-A150
150
CG-B
CG-B
24/12
24/12
EF-2
10/8
CO
LD D
UC
T
M2.00
MECHANICALFLOORPLANS
WOMEN'SSWIM LOCKER
128
MEN'SSWIM LOCKER
125
WOMEN'S SWIM LOCKER MECHANICAL FLOOR PLANM2.00
2SCALE: 1/4" = 1'-0"
MEN'S SWIM LOCKER MECHANICAL FLOOR PLANM2.00
1SCALE: 1/4" = 1'-0"
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
NUMBERED NOTES:REMOVE AND LEGALLY DISPOSE OF ALL EXISTINGDIFFUSERS AND GRILLES.
REMOVE EXISTING DUCT RUN OUTS BETWEEN DUCTAND DIFFUSERS AND GRILLES. CAP, SEAL, AND INSULATEDUCTWORK AT END POINT OF DEMOLITION FOR RUNOUT REMOVAL.
REMOVE AND LEGALLY DISPOSE OF EXISTING EXHAUSTWALL CAPS.
REMOVE AND LEGALLY DISPOSE OF EXISTING LOCKERROOM EXHAUST FANS.
PROVIDE AND INSTALL LOCKER ROOM EXHAUST FANPER EXHAUST FAN SCHEDULE.
PROVIDE AND INSTALL DIFFUSERS AND GRILLES PERTHE DIFFUSER AND GRILLE SCHEDULE.
PROVIDE AND INSTALL SCREW IN TYPE DUCT TAPSWHERE INDICATED. DUCT TAPS SHALL BE PROVIDEDWITH MANUAL VOLUME DAMPERS FOR BALANCING.
PROVIDE AND INSTALL 16/12 HURRICANE RATEDEXHAUST LOUVER. INSTALL 12" DEEP PLENUM BEHINDLOUVER, SEAL WATER TIGHT AND CONNECT EXHAUSTDUCT WITH DUCT TRANSITION.
PROVIDE TRANSITION TO CONNECT EXISTING FLEXIBLEDUCT TO DIFFUSER
1
2
3
4
5
6
7
8
9
KEY PLAN
M3.00
MECHANICALDETAILS
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
AND ATT ANGLES ARE WELDED TOGETHERAND SHIPPED LOOSE.
3/8"
AND LOUVER TYP. (NIRC)SEALANT BETWEEN SLEEVE
1/8"3/8"
TYP. (NIRC)
2" X 8" OR AS REQUIRED X 2" X 1/8" CONT FORMEDALUM CHANNELS (4 REQ'D) INSTALLED AROUNDPERIMETER OF LOUVER OPENING. CHANNELS
SEALANT BETWEEN SLEEVE AND LOUVER
EME6625D LOUVER
2" X 4" X 3/16" CONT FORMED ALUMATT. ANGLE WELDED TO PERIMETER CHANNEL.
X 1" LG HWH # SELF DRILLING SCREWSAND ATTACHED TO LOUVER W/ HILTI 1/4-14
12" O/C & 3" FROM ENDS.
6"
STRUCT. (NIRC)
1/8"
"D" "B" R.O.
STRUCTURAL JOIST
1/2" THREADEDROD (TYP).
1-1/4 X 1-1/4 X 3/16ANGLE IRON SUPPORTS.
1/2" BOLT AND NUTW/ 2" 1/2 WASHER.
DUCT HANGER DETAILN.T.S.
NUTS AND WASHERS BOTHSIDES OF ANGLE (TYP).
N.T.S.
FROM STRUCTURE
SAME AS DIFFUSERINLET: 5'-0" MAX
FLEXIBLE DUCT SIZE
LENGTH.
12"
CEILING
SUPPORT SADDLE
VOLUME DAMPER W/LOCKING QUADSADDLE
SHEET METAL
CONICAL OUTLET
BRANCH DUCT
FOR CHANGE OFDIRECTION GREATER
USE RIGID ELBOWS
THAN 45°
FLEXIBLE AIR DUCT CONNECTOR
SEE SPECIFICATIONS FOR CLAMPSAND SEALANT (TYP.)
NOTE:THE USE OF FLEXIBLE AIR DUCT CONNECTORS ARE NOT PERMITTED FORTHE DEDICATED AHU SERVING THE SURGICAL SUITE.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
ELECTRICAL
PLANCEILINGREFLECTED
E1.00
”
”
”
L. WESTG. LINTINGER
KEY PLAN
WOMEN'SSWIM LOCKER
128
MEN'SSWIM LOCKER
125
WOMEN'S SWIM LOCKER ELECTRICAL POWER PLANE2.00
2SCALE: 1/4" = 1'-0"
MEN'S SWIM LOCKER ELECTRICAL POWER PLANE2.00
1SCALE: 1/4" = 1'-0"
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
PLANPOWERELECTRICAL
E2.00
L. WESTG. LINTINGER
KEY PLAN
P1.00
PLUMBINGFLOORPLANS
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
NOTES: SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS
PLUMBING FIXTURESMARK FIXTURES WASTE C.W. H.W. BASIS OF DESIGN
WC WATER CLOSET 3" 1" -AMERICAN STANDARD 2854.016 - FLOOR MOUNT, ELONGATED BOWL, FLOOR OUTLET, WHITE VITREOUS CHINA,1.6/1.1GPF, & BOLT CAPS, AMERICAN STANDARD 5905.100 EXTRA HEAVY DUTY SEAT, OPEN FRONT LESS COVER, ANDAMERICAN STANDARD 6067.761.002 DUAL FLUSH TOILET FLUSH VALVE, ADA AND ANSI A117.1 COMPLIANT.
WC-H ACCESSIBLE WATER CLOSET 3" 1" -AMERICAN STANDARD 2854.016 - FLOOR MOUNT, ELONGATED BOWL, FLOOR OUTLET, WHITE VITREOUS CHINA,1.6/1.1GPF, & BOLT CAPS, AMERICAN STANDARD 5905.100 EXTRA HEAVY DUTY SEAT, OPEN FRONT LESS COVER, ANDAMERICAN STANDARD 6067.761.002 DUAL FLUSH TOILET FLUSH VALVE, ADA AND ANSI A117.1 COMPLIANT.
UR URINAL 2" 3/4" -AMERICAN STANDARD 6590.501 - EXPOSED TOP SPUD URINAL, WHITE VITREOUS CHINA, FLUSHING RIM, 3/4" TOP SPUD,WITH ADA AND ANSI A117.1 COMPLIANT, AMERICAN STANDARD 6045.051 - 0.5 GPF MANUAL FLUSH VALVE.
LAV LAVATORY 1-1/2" 1/2" 1/2"
AMERICAN STANDARD 0614000.020 - RECTANGULAR UNDERCOUNTER MOUNT SINK, WHITE, VITREOUS CHINA, FRONTOVERFLOW, 4" O.C. FAUCET MOUNTS, MEETS ADA GUIDELINES AND ANSI A117.1, WITH AMERICAN STANDARD 8123F -DUAL CONTROL 4" CENTERSET LAVATORY FAUCET POLISHED CHROME FINISH, ADA COMPLIANT, W/VANDAL-RESISTANTAERATOR & 0.5 GPM INSERT, AND DRAIN; PRO-EXTREME X4333 P-TRAP & SUPPLY COVER. SHALL MEET ANSI A117.1 ANDADA STANDARDS.
SH SHOWER - 1/2" 1/2"BRADLEY SHOWER VALVE S59-2005 - THERMOSTATIC MIXING VALVE, ASSE 1016 TYPE T CERTIFIED, BRADLEY STANDARDINSTITUTIONAL SHOWERHEAD (S) - CHROME PLATED ARM WITH STAINLESS WALL FLANGE, ADJUSTABLE SPRAYPATTERN, 2.5 GPM FLOW CONTROL
SH-AC ACCESSIBLE SHOWER - 1/2" 1/2"BRADLEY SHOWER VALVE S59-2005 - THERMOSTATIC MIXING VALVE, ASSE 1016 TYPE T CERTIFIED, BRADLEY HANDSHOWER MODEL B24 - ON/OFF CONTROL WITH A NON-POSITIVE SHUT-OFF, MEETS ANSI A112.18.1M FLOWREQUIREMENTS.
MATERIALS, EQUIPMENT, AND SYSTEMS SHALL MEET ALL PERTINENTREQUIREMENTS OF THE UNDERWRITERS LABORATORY (UL), THEAMERICAN SOCIETY FOR TESTING MATERIALS (ASTM), THE 2013 LOUISIANASTATE PLUMBING CODE, AMERICAN WATER WORKS ASSOCIATION (AWWA),AND OTHER NATIONALLY RECOGNIZED AGENCIES AS WELL AS APPLICABLELOCAL CODES.
BIDDERS SHALL BE LICENSED CONTRACTORS IN ACCORDANCE WITH LOCALAND STATE LAWS.
BIDDERS SHALL THOROUGHLY ACQUAINT THEMSELVES WITH THECONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED. THEY SHALLEXAMINE ALL SERVICES, EQUIPMENT, SURFACES, ETC., WHICH THIS WORKIS IN ANY WAY DEPENDENT UPON, AND BRING ANY DISCREPANCIESDETERMINED OR OMISSIONS FOUND IN THE DRAWINGS TO THE OWNER'SATTENTION BEFORE SUBMITTING BID.
ALL INSTALLED SYSTEMS, DEVICES AND RELATED ITEMS SHALL BE TESTEDIN PLACE ON SITE. REPLACE ANY AND ALL CONTRACTOR SUPPLIEDDEFECTIVE DEVICES, ITEMS OR SYSTEMS AT CONTRACTOR'S OWNEXPENSE BEFORE COMPLETION OF THE PROJECT.
CONTRACTOR SHALL GUARANTEE ALL WORK FOR WHICH MATERIALS AREFURNISHED, FABRICATED OR FIELD ERECTED, ALL FACTORY ASSEMBLEDEQUIPMENT FOR WHICH NO SPECIFIC MANUFACTURER'S GUARANTEE ISFURNISHED, AND ALL WORK IN CONNECTION WITH INSTALLINGMANUFACTURER'S GUARANTEED EQUIPMENT. THIS CONTRACTOR'SGUARANTEE SHALL EXIST FOR A PERIOD OF ONE (1) YEAR FROM THE DATEOF FINAL OWNER ACCEPTANCE OF THE WORK AND SHALL APPLY TODEFECTS IN MATERIAL AND TO DEFECTIVE WORKMANSHIP OF ANY KIND.
THE SYSTEMS SHOWN ON THE DRAWINGS SHALL BE PROVIDED TO SERVEALL FIXTURES, EQUIPMENT, AND AREAS WITHIN THE CONTRACT LIMIT LINESAS SET FORTH BY THE ARCHITECTURAL SOLUTION FOR THE PROJECT.SYSTEMS SHALL INCLUDE ALL EQUIPMENT, APPURTENANCES, SAFETYDEVICES, AND CONTROLS NECESSARY FOR THE INTENDED SERVICE.
ALL PERMITS AND FEES REQUIRED FOR THE WORK SHALL BE SECUREDAND PAID FOR BY THE PLUMBING CONTRACTOR AND INCLUDED IN BIDPRICE.
ANYTHING DRAWN OR SPECIFIED ON THESE PLANS SHALL NOT BECONSTRUED TO CONFLICT WITH ANY LOCAL, MUNICIPAL OR STATE LAW,REGULATION OR ORDINANCE WHICH GOVERNS THE INSTALLATION OF ANYPLUMBING OR RELATED WORK. WHERE ANY PORTION OF THE SYSTEMS ISNOT INSTALLED AS IN ACCORDANCE WITH APPLICABLE LAWS,ORDINANCES, REGULATIONS AND CODES, THIS CONTRACTOR SHALL MAKEALL CHANGES REQUIRED BY THE ENFORCING AUTHORITIES IN A MANNERAPPROVED BY THE OWNER AND WITHOUT ADDITIONAL COST TO THEOWNER.
WHERE JOB CONDITIONS REQUIRE CHANGES FROM THE CONTRACTDOCUMENTS THAT DO NOT CHANGE THE SCOPE OF INSTALLATION ORNATURE OF WORK REQUIRED, THE CONTRACTOR SHALL MAKE SUCHCHANGES WITHOUT ADDITIONAL COST TO THE OWNER. NO OTHERCHANGES MAY BE MADE WITHOUT WRITTEN PERMISSION OF THE OWNER.
ALL EQUIPMENT AND FIXTURES SHALL BE NEW AND UNUSED ANDINSTALLED IN STRICT CONFORMANCE TO MANUFACTURER'SRECOMMENDATIONS. PROVIDE FIXTURES COMPLETE WITH ALL TRIM,STOPS, HANGERS, CARRIERS, SUPPORTS, ETC. INCLUDING PROVISION FORTHE HANDICAPPED, IF REQUIRED. WHERE FIXTURES ARE ACCESSIBLE TOTHE HANDICAPPED, FIXTURES MUST COMPLY WITH ALL FEDERAL ADAREGULATIONS.
ARRANGE FOR CHASES, SLOTS, AND OPENINGS IN OTHER BUILDINGCOMPONENTS TO ALLOW FOR PLUMBING INSTALLATIONS. COORDINATETHE CUTTING AND PATCHING OF BUILDING COMPONENTS TOACCOMMODATE INSTALLATION OF PLUMBING EQUIPMENT AND MATERIALS.
DO NOT ENDANGER OR DAMAGE INSTALLED WORK THROUGHPROCEDURES AND PROCESSES OF CUTTING AND PATCHING. PROVIDEREPAIRS REQUIRED TO RESTORE OTHER WORK, BECAUSE OF DAMAGECAUSED AS A RESULT OF PLUMBING INSTALLATIONS.
SEQUENCE, COORDINATE, AND INTEGRATE INSTALLATIONS OF PLUMBINGMATERIALS AND EQUIPMENT FOR EFFICIENT FLOW OF THE WORK.
WHERE MOUNTING HEIGHTS ARE NOT DETAILED OR DIMENSIONED, INSTALLPLUMBING SERVICES AND OVERHEAD EQUIPMENT TO PROVIDE THEMAXIMUM HEADROOM POSSIBLE.
INSTALL PLUMBING EQUIPMENT TO FACILITATE MAINTENANCE AND REPAIROR REPLACEMENT OF EQUIPMENT COMPONENTS. AS MUCH ASPRACTICAL, CONNECT EQUIPMENT FOR EASE OF DISCONNECTING, WITHMINIMUM OF INTERFERENCE WITH OTHER INSTALLATIONS.
COORDINATE THE INSTALLATION OF PLUMBING MATERIALS ANDEQUIPMENT ABOVE CEILINGS WITH SUSPENSION SYSTEM, LIGHT FIXTURES,DUCTWORK, CONDUIT, AND OTHER INSTALLATIONS. COORDINATEPLUMBING EQUIPMENT AND MATERIALS INSTALLATION WITH OTHERBUILDING COMPONENTS.
ALL PIPES SHALL BE OF THE SIZE GIVEN ON THE DRAWINGS. ALL PIPINGSHALL BE RUN TRUE TO LINE. PIPES MAY BE MOVED, IF NECESSARY FORINSTALLATION, PROVIDED THAT THE NATURE OF THE SYSTEM IS NOTCHANGED. ALL PIPES SHALL BE CONCEALED: LOCATED ABOVE CEILING,BELOW FLOOR OR IN WALLS, EXCEPT WHERE CONNECTION IS MADE TOFIXTURE.
ACTUAL LOCATIONS AND MOUNTING METHODS FOR FIXTURES ANDPENETRATIONS ARE SUBJECT TO ARCHITECT'S APPROVAL. VERIFY ALLDIMENSIONS BY FIELD MEASUREMENTS.
THE HOT AND COLD WATER SUPPLY LINE BRANCHES FOR ALL LAVATORIES,SHOWERS, AND HOSE BIBBS SHALL HAVE JOSAM OR ZURN WATER HAMMERARRESTERS INSTALLED ON THE HIGH POINT AT THE END OF EACH BRANCHLINE.
GENERAL PLUMBING NOTES
HOT WATER LINE
WASTE AND VENT
VENTV
HW HOT WATER
FD FLOOR DRAIN
CW COLD WATERCO CLEAN OUT
BALL VALVE
COLD WATER LINE
SANITARY SEWER
HOT WATER CIRCULATION LINE
HOSE BIBBHB
W
W&V
WASTE
S
REDUCER
SHOWERSH
PIPE DOWNPIPE UP
MECHANICAL CONTRACTORMC
UNLESS OTHERWISE NOTEDUON
LAVATORYLAV
WATER CLOSETWC
DW DISHWASHER
BELOW FINISHED FLOORBFF
NOT TO SCALENTS
SUMP PUMPSP
AREA DRAINAD
GENERAL CONTRACTORGC
PLUMBING CONTRACTORPC
VENT
SHUTOFF VALVE
FLOOR CLEANOUT
HOSE BIBB
C. BOYERM. LEITZINGER
CONNECT TO EXISTING
END POINT OF DEMOLITION
3
4
3
6
5
1
1
1
1
2
5
ETR CW
ETR
CW
ETR 2"
ETR 1-1/2"
ETR 3/4"
ETR
2"
ETR 1-1/2"
ETR 3/4"
ETRFD
ETRFD
ETRFD
ETRSHOWERDRAIN
ETRSHOWERDRAIN
DEMO SH
DEMO SH
DEMO SH
DEMO SH
DEMO WC
DEMO WC
DEMO WC
DEMO LAV
DEMO LAV
2
1
1
1
1
8
3
3
3
55
7
7
7
ETR
2"
ETR
1-1/2"
ETR
1"
3/4"
ETRSHOWERDRAIN
DEMO SH
DEMO SH
DEMO SH
DEMO SH
DEMO WC
DEMO WC
DEMO UR
DEMO URDEMO LAV
DEMOLAV
6
ETRSHOWERDRAIN
ETRFD
ETRFD
ETRFD
P2.00
PLUMBINGDEMOLITIONPLANS
WOMEN'SSWIM LOCKER
128
MEN'SSWIM LOCKER
125
WOMEN'S SWIM LOCKER PLUMBING DEMOLITION PLANP2.00
2SCALE: 1/2" = 1'-0"
MEN'S SWIM LOCKER PLUMBING DEMOLITION PLANP2.00
1SCALE: 1/2" = 1'-0"
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
KEY PLAN
NUMBERED NOTES:REMOVE AND LEGALLY DISPOSE OF EXISTING SHOWERHEADS AND SHOWER VALVES. CAP WATER PIPING FORFUTURE USE.
DEMOLISH EXISTING SHOWER. CAP EXISTING SHOWERCW AND HW SUPPLY PIPING INSIDE WALL. PATCH ANDREPAIR WALL TO MATCH ADJACENT SURFACE.
DEMOLISH EXISTING WATER CLOSETS. CAP CW PIPE ATWALL FOR FUTURE USE.
DEMOLISH EXISTING WATER CLOSET. CAP AND SEALEXISTING WATER CLOSET SANITARY DRAIN BELOWSLAB. REROUTE CW PIPING FOR FUTURE USE. SEESHEET P3.00 FOR LOCATION. PATCH AND REPAIR WALLTO MATCH ADJACENT SURFACES.
DEMOLISH EXISTING LAVATORIES. CAP CW AND HWPIPING AT WALL FOR FUTURE USE.
DEMOLISH EXISTING LAVATORY. CAP EXISTINGLAVATORY HW AND CW SUPPLY PIPING INSIDE WALL.PATCH AND REPAIR WALL TO MATCH ADJACENTSURFACES.
REROUTE EXISTING LAVATORY CW AND HW PIPING TONEW LAVATORY LOCATION. SEE SHEET P3.00 FORLOCATION.
DEMOLISH EXISTING URINAL. REROUTE EXISTING CWPIPING TO NE URINAL LOCATION FOR FUTURE USE. SEESHEET P3.00 FOR NEW LOCATION. CAP EXISTINGSANITARY WASTE PIPE INSIDE WALL. PATCH AND REPAIRWALL TO MATCH ADJACENT SURFACES.
CAP AND SEAL EXISTING WASTE, HW, AND CW PIPES,FOR PREVIOUSLY REMOVED LAV, INSIDE WALL. PROVIDEACCESS COVER AT WALL FACE.
1
2
3
4
5
6
7
8
C. BOYERM. LEITZINGER
9
SH
WC
WC
WC-H
SH
SH
SH-AC
LAV
LAV
6
5
5
5
3
3
1
1
1
2
ETR CW
ETR
CW
ETR 2"
ETR 1-1/2"
ETR 3/4"
ETR
2"
ETR 1-1/2"
ETR 3/4"
ETRFD
ETRFD
ETRFD
ETRSHOWERDRAIN
ETRSHOWERDRAIN
12 13
12 13
12 13
12 13
12 13
12 13
14
14
14
SH-AC
SH
SH
SH
WC
WC-H
URUR
LAV LAV LAV
6
6
6
6
1
1
9
8
9
3 3 3
4 108
ETR
2"
3/4"
2"3/4"
3/4"
3/4"
ETR
1-1/2"
ETR
1"
ETRSHOWERDRAIN
ETRSHOWERDRAIN
ETRFD
ETRFD
ETRFD
12 13
12 13
12 13
12 13
12 13
12 13
14
14
14
14
WOMEN'SSWIM LOCKER
128MEN'S
SWIM LOCKER125
WOMEN'S SWIM LOCKER PLUMBING FLOOR PLANP3.00
2SCALE: 1/2" = 1'-0"
MEN'S SWIM LOCKER PLUMBING FLOOR PLANP3.00
1SCALE: 1/2" = 1'-0"
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
CIVILSTRUCTURALMECHANICALELECTRICALMARINE
P3.00
PLUMBINGFLOORPLANS
KEY PLAN
NUMBERED NOTES:PROVIDE AND INSTALL WC WITH FLUSH VALVE LEVEL ONFLOOR. CONNECT TO EXISTING CW PIPING ANDEXISTING SANITARY WASTE DRAIN. PROVIDE ALLNECESSARY COMPONENTS FOR A FULLY FUNCTIONALWATER CLOSET.
SAW CUT SLAB, TRENCH AND INSTALL 3" SANITARYWASTE DRAIN FOR WATER CLOSET. CONNECT TOEXISTING SANITARY LINE BELOW SLAB. VERIFYLOCATION OF EXISTING SANITARY LINE IN FIELD.REROUTE EXISTING CW PIPING TO NEW WATER CLOSETLOCATION.
PROVIDE AND INSTALL LAVATORY WITH FAUCET UNDERCOUNTER. PROVIDE LAVATORY WITH NEW 1/4 TURNSHUTOFF VALVES FOR HW AND CW CONNECTIONS ANDALL REQUIRED TRIM AND PROTECTIVE INSULATION.CONNECT TO EXISTING CW, HW, AND SANITARY PIPING.
REROUTE EXISTING CW AND HW PIPING TO NEWLAVATORY LOCATION.
PROVIDE SHOWER HEAD ON EXISTING SHOWER SUPPLYPIPING. PROVIDE SHOWER VALVE. CONNECT TOEXISTING CW AND HW PIPING. PATCH AND REPAIR WALLTO MATCH ADJACENT SURFACES AS NECESSARY.
PROVIDE PROVIDE AND INSTALL ACCESSIBLE SHOWERWITH SHOWER WAND. CONNECT SHOWER VALVE TOEXISTING CW AND HW PIPING. PATCH AND REPAIR WALLTO MATCH ADJACENT SURFACES AS NECESSARY.
PROVIDE AND INSTALL URINAL. CONNECT TO EXISTINGCW AND SANITARY PIPING.
REROUTE EXISTING URINAL CW PIPING TO NEW URINALLOCATION. PROVIDE AND INSTALL URINAL ANDCONNECT TO CW AND SANITARY PIPING.
VERIFY SANITARY DRAIN PIPING INSIDE WALL IS AMINIMUM OF 2" FOR CONNECTION TO URINAL.
REROUTE EXISTING SANITARY PIPING TO NEWLAVATORY LOCATION.
PROVIDE WATER HAMMER ARRESTORS AT EACHFIXTURE INSTALLED.
RELOCATE SHOWER HEADS TO MATCH NEW CEILINGGRID PATTERN. PROVIDE FLEXIBLE SPRINKLER HEADCONNECTIONS. REFER TO ARCHITECTURAL DRAWINGSFOR REFLECTED CEILING PLAN LAYOUT.
REPLACE EXISTING SPRINKLER HEADS WITH RECESSEDCONCEALED TYPE HEADS.
CONTRACTOR SHALL VIDEO INSPECT EXISTING WASTELINES FOR EACH FIXTURE AND BELOW THE SLAB TOENSURE PROPER DRAINAGE. ANY LINE FOUND TO BEFULLY OR PARTIALLY CLOGGED, SHALL BE CLEARED BYTHE CONTRACTOR.
1
2
3
4
5
6
7
8
9
10
C. BOYERM. LEITZINGER
11
12
13
14
Sheet Number:
Cop
yrig
ht 2
014
Date Issued:
Revisions:
January 9, 2015
Project Number:RCLC
Drawn By:Checked By:
LOC
KER
RO
OM
REN
OV
ATI
ON
S
21436
NEW
OR
LEA
NS,
LO
UIS
IAN
A 7
0122
1500
LA
FREN
IER
E ST
REE
T
900 W. Causeway ApproachMandeville, LA 70471
985-727-4440Fax: 985-727-4467
829 Baronne St.New Orleans, LA 70113
504-837-7346
RCL ARCHITECTURE, L.L.C.
This drawing and design is the exclusiveproperty of Richard C. Lambert Consultants, LLC
and may not be reproduced or used withoutauthorization and written permission. 2014
at th
e ST
. BER
NA
RD
CEN
TER
CIT
Y o
f NEW
OR
LEA
NS
Engineering Consultants, LLCNEW ORLEANS, LA 504-304-0548
PRIOR TO DRILLING, CHECK STRANDLOCATION w/HOLLOW CORE MFR. DO NOTCONTACT PRESTRESSING STEEL.
INSULATIONPROTECTIONSHIELD
CLEVIS BOLT SPACER
HANGER SCHEDULE
3/8"
3/8"
ROD SIZE
3/8"
1/2"
3/8"
3/8"
3/4"
1/2"
CAST IRON PIPE
8" AND LARGE
5" & 6"
4" AND SMALLER
DUCTILE IRON PIPE
5'-0" O.C. & AT EVERY JOINT
5'-0" O.C. & AT EVERY JOINT
5'-0" O.C. & AT EVERY JOINT
9'-0" C.O.2 1/2"
1"
COPPER TUBING
3/4" AND SMALLER
1 1/4"
1 1/2"-2"
6'-0" O.C.
5'-0" O.C.
8'-0" O.C.
7'-0" O.C.
SUPPORT SPACING NOTES
1 AND 2
ROD SIZESUPPORT SPACING NOTES
10 FT. MAX SPACING: ONE PIPESECTION AT JOINTS, AT CHANGEOF DIRECTION AND AT BRANCHCONNECTION
20 FT. MAX SPACING: MIN OF ONE (1) HANGER PER PIPE SECTION NEAR JOINT BEHIND BELL, AT CHANGE OF DIRECTIONAND BRANCH CONNECTIONS.
-
-
-
-
HANGER NOTES:
1. RODS MAY BE REDUCED ONE SIZE FOR DOUBLE ROD HANGERS WITH 3/8 IN. MINIMUM DIAMETER.
2. HANGERS ON INSULATED SYSTEMS SHALL INCORPORATE PROTECTION SADDLES OR SHIELDS OR SHALL BE CLAMPED OR WELDED TO THE PIPE AND PROJECT THROUGH THE INSULATION TO PROVIDE EXTERNAL ATTACHMENT.
3. INSULATING SLEEVES SHALL BE PROVIDED ON HANGERS FOR COPPER OR ANY DISSIMILAR METAL FROM THE HANGER.