939 - PARTITIONING AND SOURCING OF DRY SEASON EVAPOTRANSPIRATION WITHIN EDDY COVARIANCE TOWER FOOTPRINT Enrico Balugani ITC, Uniiversity Twente, Enschede, Netherlands Maciek Waclaw Lubczynski ITC, Uniiversity Twente, Enschede, Netherlands Leonardo Reyes-Acosta ITC, Uniiversity Twente, Enschede, Netherlands Christiaan Van Der Tol ITC, Uniiversity Twente, Enschede, Netherlands Klaas Metselaar Wageningen University, Wageningen University, Wageningen, Netherlands Evapotranspiration (ET) is a lump term that represents two different processes, evaporation (E) and transpiration (T). Both processes are characterized by different principles (physical and biological) and different spatial and temporal patterns. The two fluxes, E and T, have also different subsurface sources, i.e. originate either from groundwater, Eg and Tg, or from unsaturated zone, Eu and Tu. In this study carried out in the granitic, shallow water table Sardon Catchment in Spain, we attempted to quantify all the four subsurface ET components and to compare their sum with ET estimated by eddy covariance tower. The experiment was carried out in two dry seasons (2009 and 2010), i.e. when grass was dormant, within sparsely vegetated by oak trees (~7% crown cover) footprint of the eddy covariance tower. The T of the oak trees was estimated by sap flow measurements whereas its sourcing into Tg and Tu components, by stable isotopes. The bare soil E was estimated by coupled liquid water, water vapor and heat flow, HYDRUS modeling, carried out in soil moisture profiles, while its sourcing into Eg and Tg, by HYDRUS/SOURCE modeling. Due to low canopy cover, T accounted only for ~ 6 % of ET (~ 0.5 mm d -1 ) while Tg was approximately equal to Tu, did not depend on water table depth and did not change significantly between dry seasons with different moisture status. The E was the main ET flux while Eg was ~1/3 of Eu. The comparison of the sum of all estimated ET components with ET of the eddy covariance tower, for dry season 2009 indicated very good match with only 1% error while for dry season 2010, the error was ~32%, mainly because of large number of low quality, rejected eddy data. The study emphasized the importance of typically neglected Eg. It also pointed at importance of Tg, which in this study was low, but only because of sparse oak tree cover. In dry environments, the Eg and Tg groundwater fluxes represent important components of groundwater balances so must not be disregarded in groundwater modeling and groundwater resources estimates. Therefore, more research in that direction is needed. Session S5.8 - Aqua 2015 - 42 nd IAH Congress 1
2
Embed
939 - PARTITIONING AND SOURCING OF DRY SEASON ... · RESULTS: PARTITIONING AND SOURCING OF DRY SEASON EVAPOTRANSPIRATION WITHIN EDDY COVARIANCE TOWER E. Balugani1, M. W. Lubczynski1*,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
939 - PARTITIONING AND SOURCING OF DRY SEASON EVAPOTRANSPIRATION WITHIN EDDY COVARIANCE TOWER FOOTPRINT
Evapotranspiration (ET) is a lump term that represents two different processes, evaporation (E) and transpiration (T). Both processes are characterized by different principles (physical and biological) and different spatial and temporal patterns. The two fluxes, E and T, have also different subsurface sources, i.e. originate either from groundwater, Eg and Tg, or from unsaturated zone, Eu and Tu.
In this study carried out in the granitic, shallow water table Sardon Catchment in Spain, we attempted to quantify all the four subsurface ET components and to compare their sum with ET estimated by eddy covariance tower. The experiment was carried out in two dry seasons (2009 and 2010), i.e. when grass was dormant, within sparsely vegetated by oak trees (~7% crown cover) footprint of the eddy covariance tower. The T of the oak trees was estimated by sap flow measurements whereas its sourcing into Tg and Tu components, by stable isotopes. The bare soil E was estimated by coupled liquid water, water vapor and heat flow, HYDRUS modeling, carried out in soil moisture profiles, while its sourcing into Eg and Tg, by HYDRUS/SOURCE modeling.
Due to low canopy cover, T accounted only for ~ 6 % of ET (~ 0.5 mm d-1) while Tg was approximately equal to Tu, did not depend on water table depth and did not change significantly between dry seasons with different moisture status. The E was the main ET flux while Eg was ~1/3 of Eu. The comparison of the sum of all estimated ET components with ET of the eddy covariance tower, for dry season 2009 indicated very good match with only 1% error while for dry season 2010, the error was ~32%, mainly because of large number of low quality, rejected eddy data.
The study emphasized the importance of typically neglected Eg. It also pointed at importance of Tg, which in this study was low, but only because of sparse oak tree cover.
In dry environments, the Eg and Tg groundwater fluxes represent important components of groundwater balances so must not be disregarded in groundwater modeling and groundwater resources estimates. Therefore, more research in that direction is needed.
Session S5.8 - Aqua 2015 - 42nd
IAH Congress
1
RESULTS:
PARTITIONING AND SOURCING OF DRY SEASON EVAPOTRANSPIRATION WITHIN EDDY
COVARIANCE TOWER E. Balugani1, M. W. Lubczynski1*, J. Leonardo Reyes-Acosta1, C. van der Tol1
1 - Water resources, ITC-Twente University, Hengelosestraat 99, 7514 AE, Enschede, The Netherlands; * - poster presentar
MATERIALS AND METHODS:
Evaporation (ET): • Eddy covariance tower placed
in a semi-arid, water-limited
climate, with almost no rain
events during summer
• Eddy tower footprint
calculated using the approach
of Hsieh et al. (2000).
• The footprint calculation
shows that all the footprint
measurements come from a
distance < 2 km from the
station.
OBJECTIVES: 1. To partition evapotranspiration
(ET) measured by eddy
covariance (EC) tower into
evaporation (E) and transpiration
(T) during dry season in a semi-
arid environment.
2. To source E and T into their
groundwater (Eg, Tg) and
unsaturated zone (Eu, Tu)
components.
RESEARCH NICHE: • The sap flow measurements are
usually taken with the most economic
Granier method, which if not properly
handled, typically results in serious
overestimation of T.
• Calculation of bare-soil
evaporation is usually over-simplified
by not accounting for vapor flow,
which can result in substantial
underestimation of E.
• To our knowledge, nobody ever
tried to source and partition ET into its
components Eg, Eu, Tg and Tu..
Transpiration (T): • Two main tree species in the study area: Quercus pyrenaica and
Quercus ilex.
• Sap-flow measured and optimized using combination of thermal
dissipation probe (TDP) and heat field deformation (HFD) sensors
• Sap-flow upscaling procedure:
1. Tree classification map (canopy coverage, species type)
2. Develop an upscaling function for each species
3. Apply the upscaling function to obtain a transpiration map for
the whole investigated area
• Isotopic experiments to measure (source) Tg and Tu .
• Elaboration of half-hour maps of transpiration (Tg and Tu) for a
square area of 2 km side with the eddy tower in the centre.
Evaporation (E): • Sandy loam soils, laying on weathered and fractured granite.
• Shallow groundwater (0.5 m to 10 m).
• Water table and soil hydraulic properties measured.
• Soil profiles equipped with soil moisture, temperature and
matric potential sensors at different depth.
• Soil modeled with Hydrus1D using equations for the coupled
water vapor flow.
• E sourced into Eu and Eg with the SOURCE post-processing
package.
• Elaboration of half-hour maps of evaporation (Eu and Eg) for a
square area of 2x2 km with the eddy tower in the centre.