8th IWA Specialist Group Conference on Waste Stabilization Ponds - Belo Horizonte/MG , April 2009 Trickling filters: Alternative for Ammonia Removal from Stabilization Pond System Effluent Mônica Medeiros Frederico de Almeida Lage Filho Humberto Carlos Ruggeri Roque Passos Piveli
13
Embed
8th IWA Specialist Group Conference on Waste Stabilization Ponds - Belo Horizonte/MG , April 2009
8th IWA Specialist Group Conference on Waste Stabilization Ponds - Belo Horizonte/MG , April 2009. Trickling filters: Alternative for Ammonia Removal from Stabilization Pond System Effluent Mônica Medeiros Frederico de Almeida Lage Filho Humberto Carlos Ruggeri - PowerPoint PPT Presentation
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
8th IWA Specialist Group Conference on Waste Stabilization Ponds - Belo Horizonte/MG , April 2009
Trickling filters: Alternative for Ammonia Removal from Stabilization Pond System
Effluent
Mônica Medeiros Frederico de Almeida Lage Filho
Humberto Carlos Ruggeri Roque Passos Piveli
Introduction Hundreds of active Stabilization Ponds in Brazil
However they don´t have nutrient removal capabilities and don´t meet discharge standards.
Atractive alternative is ponding system effluent application in agriculture: “fertirrigation”.
During wet weather periods effluent application into agricultural soils is troublesome need for post-treatment of ponding system effluent.
Intro (continued) One option for post-treatment of ponding system
effluents is the TRICKLING BIOFILTER (TBF): an attached biomass growth reactor in which biological NITRIFICATION can take place.
TBF´s present small footprint pH, temperature, BOD and ponding system
effluent OD conditions are favorable to nitrification.
Resulting reactor volume quite possibly smaller than other post-treatment options, thus TBF option can be economically feasible.
Research Work Objective
Evaluate effects of TKN and BOD application rates as well as other operational conditions on nitrification in tricking biofilters receiving photosynthetic facultative pond effluent.
Bigger picture:
Experimental results to subsidize assessment of the TBF alternative for improvement of ponding
system effluent quality.
Methodology
Ponding System at city of Lins, SP Estabilização de Lins/SP
At the Lins field Station – testing field for agricultural reuse of ponding system effluent
MethodologyTKN Volumetric Loading rates: 0,02 to 0,17 kg TKN/m3d Surface Hydraulic Loading rates: 2 to 12 m3/m2d