Top Banner
Automationforum.in Automationforum.in Page 1 of 15 SYMBOLS & STANDARDS 1) INSTRUMENT ABBREVIATIONS PRESSURE P : PRESSURE PI : PRESSURE INDICATOR PG : PRESSURE GAUGE PCV : PRESSURE CONTROL VALVE PT : PRESSURE TRANSMITTER PIT : PRESSURE INDICATING TRANSMITTER PIC : PRESSURE INDICATING CONTROLLER PDT : PRESSURE DIFFERENTIAL TRANSMITTER PRV : PRESSURE REDUCING VALVE PSV : PRESSURE SAFETY VALVE PS : PRESSURE SWITCH PSH : PRESSURE SWITCH HIGH PSL : PRESSURE SWITCH LOW PSHH : PRESSURE SWITCH HIGH HIGH PSLL : PRESSURE SWITCH LOW LOW PDS : PRESSURE DIFFERENTIAL SWITCH PDSH : PRESSURE DIFFERENTIAL SWITCH HIGH PDSL : PRESSURE DIFFERENTIAL SWITCH LOW PA : PRESSURE ALARM TEMPERATURE T : TEMPERATURE TI : TEMPERATURE INDICATOR TW : THERMOWELL TM : THERMOMETER TE : TEMPERATURE ELEMENT RTD : RESISTANCE TEMPERATURE DETECTOR T/C : THERMOCOUPLE TT : TEMPERATURE TRANSMITTER TIC : TEMPERATURE INDICATING CONTROLLER TRC : TEMPERATURE RECORDER CONTROLLER TCV : TEMPERATURE CONTROL VALVE TS : TEMPERATURE SWITCH TSH : TEMPERATURE SWITCH HIGH TSL : TEMPERATURE SWITCH LOW
15

89280396-Piping-and-Instrument-Diagram-p-Id-Standard-Symbols-Detailed-Documentation.pdf

Nov 23, 2015

Download

Documents

Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • Automationforum.in

    Automationforum.in Page 1 of 15

    SYMBOLS & STANDARDS

    1) INSTRUMENT ABBREVIATIONS

    PRESSURE

    P : PRESSURE

    PI : PRESSURE INDICATOR

    PG : PRESSURE GAUGE

    PCV : PRESSURE CONTROL VALVE

    PT : PRESSURE TRANSMITTER

    PIT : PRESSURE INDICATING TRANSMITTER

    PIC : PRESSURE INDICATING CONTROLLER

    PDT : PRESSURE DIFFERENTIAL TRANSMITTER

    PRV : PRESSURE REDUCING VALVE

    PSV : PRESSURE SAFETY VALVE

    PS : PRESSURE SWITCH

    PSH : PRESSURE SWITCH HIGH

    PSL : PRESSURE SWITCH LOW

    PSHH : PRESSURE SWITCH HIGH HIGH

    PSLL : PRESSURE SWITCH LOW LOW

    PDS : PRESSURE DIFFERENTIAL SWITCH

    PDSH : PRESSURE DIFFERENTIAL SWITCH HIGH

    PDSL : PRESSURE DIFFERENTIAL SWITCH LOW

    PA : PRESSURE ALARM

    TEMPERATURE

    T : TEMPERATURE

    TI : TEMPERATURE INDICATOR

    TW : THERMOWELL

    TM : THERMOMETER

    TE : TEMPERATURE ELEMENT

    RTD : RESISTANCE TEMPERATURE DETECTOR

    T/C : THERMOCOUPLE

    TT : TEMPERATURE TRANSMITTER

    TIC : TEMPERATURE INDICATING CONTROLLER

    TRC : TEMPERATURE RECORDER CONTROLLER

    TCV : TEMPERATURE CONTROL VALVE

    TS : TEMPERATURE SWITCH

    TSH : TEMPERATURE SWITCH HIGH

    TSL : TEMPERATURE SWITCH LOW

  • Automationforum.in

    Automationforum.in Page 2 of 15

    TA : TEMPERATURE ALARM

    FLOW

    F : FLOW

    FI : FLOW INDICATOR

    FG : FLOW GLASS / FLOW GAUGE

    FE : FLOW ELEMENT

    FIT : FLOW INDICATING TRANSMITTER

    FCV : FLOW CONTROL VALVE

    FIC : FLOW INDICATING CONTROLLER

    FS : FLOW SWITCH

    FY : FLOW CONVERTER

    FA : FLOW ALARM

    FR : FLOW RECORDER

    FRC : FLOW RECORDING CONTROLLER

    LEVEL

    L : LEVEL

    LI : LEVEL INDICATOR

    LG : LEVEL GAUGE

    LIT : LEVEL INDICATING TRANSMITTER

    LCV : LEVEL CONTROL VALVE

    LDT : LEVEL DISPLACER TRANSMITTER

    LIC : LEVEL INDICATING CONTROLLER

    LRC : LEVEL RECORDING CONTROLLER

    LS : LEVEL SWITCH

    LSH : LEVEL SWITCH HIGH

    LSL : LEVEL SWITCH LOW

    LA : LEVEL ALARM

    RLT : RADAR LEVEL TRANSMITTER

  • Automationforum.in

    Automationforum.in Page 3 of 15

    GENERAL

    DCS : DISTRIBUTED CONTROL SYSTEM

    SCADA : SUPERVISORY CONTROL AND DATA ACQUISITION SYSTEM

    PLC : PROGRAMMABLE LOGIC CONTROLLER

    HART : HIGHWAY ADDRESSABLE REMOTE TRANSDUCER

    HHT : HAND HELD TERMINAL

    SFC : SMART FIELD CONFIGURATOR

    ESD : EMERGENCY SHUT DOWN

    AOV : AIR OPERATED VALVE

    MOV : MOTOR OPERATED VALVE

    SV : SOLENOID VALVE

    XVE : VIBRATION PROXIMITOR

    XVT : VIBRATION TRANSMITTER

    AE : ANALYZER

    JB : JUNCTION BOX

    ILD : INSTRUMENT LOOP DIAGRAM

    P&ID : PIPING AND INSTRUMENT DIAGRAM

    IIS : INSTRUMENT INSTALLATION SCHEDULE

    TDR : TIME DELAY RELAY

    SP : SET POINT

    NC : NORMALLY CLOSED

    NO : NORMALLY OPEN

    MCC : MOTOR CONTROL CENTRE

    IAS : INSTRUMENT AIR SUPPLY

    IGS : INSTRUMENT GAS SUPPLY

    ACFO : AIR TO CLOSE FAIL OPEN

    AOFC : AIR TO OPEN FAIL CLOSE

    FFA : FLAME FAILURE ALARM

    P/I P to I : PNEUMATIC TO CURRENT CONVERTER

    I/P I to P : CURRENT TO PNEUMATIC CONVERTER

    PB : PUSH BUTTON

    PID : PROPORTIONAL, INTEGRAL AND DERIVATIVE

    E/H : ELECTRO HYDRAULIC ACTUATOR

    BOV : BLOW DOWN VALVE

    A/M : AUTO / MANUAL 2 POSITION SWITCH

    ZS : POSITION SWITCH

    HS : HAND SWITCH

  • Automationforum.in

    Automationforum.in Page 4 of 15

    2) INSTRUMENT LINE SYMBOLS

    2.1) INSTRUMENT SUPPLY or CONNECTION TO PROCESS ___________________ 2.2) PNEUMATIC SIGNAL ___________________ 2.3) ELECTRICAL SIGNAL (ANALOG SIGNAL) (mA DC (OR) VDC) ------------------------ 3.4) ELECTROMAGNETIC or SONIC SIGNAL ___________________

    3.5) HYDRAULIC SIGNAL ___________________ 2.6) CAPILLARY TUBE (FILLED SYSTEM) ___________________

    2.7) PULSE TRAIN _ _ _ _ _ _ _ 2.8) INTERNAL SYSTEM LINK (SOFTWARE or DATA LINK) -----------------------------------------------------------------------------------------------------------------

    3) TYPES OF SUPPLY

    3.1) AS - AIR SUPPLY IA INSTRUMENT AIR PA PLANT AIR 3.2) ES ELECTRICAL SUPPLY 3.3) GS GAS SUPPLY 3.4) HS HYDRAULIC SUPPLY 3.5) NS NITROGEN SUPPLY 3.6) SS STEAM SUPPLY 3.7) WS WATER SUPPLY

    The ES or AS symbol is to be used only for Field Devices requiring supply. For panel mounted instruments power supplies are not shown on flow sheet.

    Options

    IAS 130 kPa

    ES 24 V DC

  • Automationforum.in

    Automationforum.in Page 5 of 15

    4) GENERAL INSTRUMENT SYMBOLS

  • Automationforum.in

    Automationforum.in Page 6 of 15

  • Automationforum.in

    Automationforum.in Page 7 of 15

    5) IDENTIFICATION LETTERS

    TABLE 1

    FIRST LETTER (4) SUCCEEDING LETTER (3) MEASURED / INITIATING

    VARIABLE MODIFIER READOUT /

    PASSIVE FUNCTION

    OUTPUT FUNCTION

    MODIFIER

    A ANALYSIS (5, 19) ALARM B BURNER, COMBUSTION USERS CHOICE (1) USERS CHOICE (1) USERS CHOICE (1) C USERS CHOICE (1) CONTROL (13) D USERS CHOICE (1) DIFFERENTIAL

    (4)

    E VOLTAGE SENSOR (PRIMARY ELEMENT)

    F FLOW RATE RATIO (FRACTION) (4)

    G USERS CHOICE (1) GLASS, VIEWING DEVICE (9)

    H HAND HIGH (7,15,16) I CURRENT (ELECTRICAL) INDICATE (10) J POWER SCAN (7) K TIME, TIME SCHEDULE TIME, RATE OF

    CHANGE (4, 21) CONTROL STATION

    (22)

    L LEVEL LIGHT (11) LOW (7, 15, 16) M USERS CHOICE (1) MOMENTARY

    (4) MIDDLE,

    INTERMEDIATE (7, 15)

    N USERS CHOICE (1) USERS CHOICE (1) USERS CHOICE (1) USERS CHOICE (1) O USERS CHOICE (1) ORIFICE,

    RESTRICTION

    P PRESSURE, VACUUM POINT (TEST) CONNECTION

    Q QUANTITY INTEGRATE, TOTALIZE (4)

    R RADIATION RECORD (17) S SPEED, FREQUENCY SAFETY (8) SWITCH (13) T TEMPERATURE TRANSMIT (18) U MULTIVARIABLE (6) MULTIFUNCTION (12) MULTIFUNCTION (12) MULTIFUNCTION (12)

    V VIBRATION, MECHANICAL ANALYSIS (19)

    VALVE, DAMPER, LOUVER (13)

    W WEIGHT, FORCE WELL X UNCLASSIFIED (2) X AXIS UNCLASSIFIED (2) UNCLASSIFIED (2) UNCLASSIFIED (2) Y EVENT, STATE /

    PRESENCE (20) Y AXIS RELAY, COMPUTE,

    CONVERT(13,14,18)

    Z POSITION, DIMENSION Z AXIS DRIVER, ACTUATOR, UNCLASSIFIED FINAL CONTROL ELEMENT

    NOTE: Numbers in parentheses refer to specific explanatory notes.

  • Automationforum.in

    Automationforum.in Page 8 of 15

    6) TYPICAL LETTER COMBINATIONS TABLE 2

  • Automationforum.in

    Automationforum.in Page 9 of 15

    7) FUNCTIONAL BLOCKS FUNCTIONAL DESIGNATIONS

    THE FUNCTION DESIGNATIONS ASSOCIATED WITH CONTROLLERS, COMPUTING DEVICES, CONVERTERS AND RELAYS MAY BE USED INDIVIDUALLY OR IN COMBINATION (ALSO SEE TABLE 1, NOTE 14). THE USE OF A BOX AVOIDS CONFUSION BY SETTING OFF THE SYMBOL FROM OTHER MARKINGS ON A DIAGRAM AND PERMITS THE FUNCTION TO BE USED AS A STAND ALONE BLOCK ON

    CONCEPTUAL DESIGNS.

    TABLE -3

  • Automationforum.in

    Automationforum.in Page 10 of 15

  • Automationforum.in

    Automationforum.in Page 11 of 15

  • Automationforum.in

    Automationforum.in Page 12 of 15

  • Automationforum.in

    Automationforum.in Page 13 of 15

  • Automationforum.in

    Automationforum.in Page 14 of 15

  • Automationforum.in

    Automationforum.in Page 15 of 15

    8. APPLICATION EXERCISE