4 2/2 SERIES 8040 8215 2-WAY Features • Lightweight, low-cost valves for air service • Ideal for low pressure applications • Provides high flow, Cv up to 138 (Kv 118) • Air and vacuum service Direct Acting or Piloted Aluminum Body Solenoid Valves 1/8" to 3" NPT NC NO Solenoid Enclosures Approvals: CSA certified to: 8040 Series: 1) Standard C22.2 No. 139 "Electrically Operated Valves," File 10381. 2) Automatic Gas Valves Z21.21 (6.5), File 112872. 3) Automatic Gas Safety Shutoff Valves C/I (3.9), File 112872. 8215 Series Normally Closed: 1) Standard C22.2 No. 139 "Electrically Operated Valves," File 10381. 2) Automatic Gas Valves Z21.21 (6.5), File 112872. 8215 Series Normally Open: 1) Standard C22.2 No. 139 "Electrically Operated Valves," File 10381. UL listed, as indicated. FM approved (Normally Closed only, except Catalog Numbers 8215A090 and 8215A040). RedHat II meets applicable CE directives. Refer to Engineering Section for details. Standard: RedHat II - Watertight, Types 1, 2, 3, 3S, 4, and 4X; RedHat - Type I. Optional: RedHat II - Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9; RedHat - Explosionproof and Raintight, Types 3, 7, and 9. (Except EF8215A40 and EF8215A90, which are suitable for Types 3 and 7 (C and D) only and have a T2B temperature rating code.) To order, add prefix “EF” to catalog number. See Optional Features Section for other available options. 8040 Valve Parts in Contact with Fluids Body Aluminum Seals, Diaphragms, Disc NBR Disc-Holder PA (10.1 and 11.6 watt Normally Open only) Core Guide CA Core Tube 305 Stainless Steel Rider Rings PTFE Core and Plugnut 430F Stainless Steel Springs* 302 Stainless Steel Shading Coil Copper * For 8040H006, 8040H007, 8040H008, spring material is 17-7 PH Standard Coil and Class of Insulation Watt Rating and Power Consumption Spare Coil Part No. DC Watts AC General Purpose Explosionproof Watts VA Holding VA Inrush AC DC AC DC F - 6.1 16 40 238210 - 238214 - F 11.6 10.1 25 70 238610 238710 238614 238714 B 14.9 - - - - 62691 - - F - 15.4 27 160 99257 - 99257 - F - 28.2 50 385 206409 - 206409 - Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz), 6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages available when required. Electrical Nominal Ambient Temp. Ranges % ^ # ) 7 Construction Series AC DC RedHat II/RedHat RedHat II RedHat 8040 -40˚F to 125˚F (-40˚C to 52˚C) - - 8215 32˚F to 125˚F (0˚C to 52˚C) 32˚F to 104˚F (0˚C to 40˚C) 32˚F to 77˚F (0˚C to 25˚C) (104˚F/40˚C occasionally) Refer to Engineering Section for details.
20
Embed
8040 8215:8040 8215 - · PDF file8040 8215 2-WAY Features • Lightweight, low-cost valves for air service ... Seals, Diaphragms, Disc NBR Disc-Holder PA (10.1 and 11.6 watt Normally
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
42/2
SERIES80408215
2-W
AY
Features• Lightweight, low-cost valves for air service
• Ideal for low pressure applications
• Provides high flow, Cv up to 138 (Kv 118)
• Air and vacuum service
Direct Acting or PilotedAluminum Body Solenoid Valves
1/8" to 3" NPT
NC
NO
Solenoid Enclosures
Approvals:CSA certified to:8040 Series:1) Standard C22.2 No. 139 "Electrically Operated
Valves," File 10381.2) Automatic Gas Valves Z21.21 (6.5), File 112872.3) Automatic Gas Safety Shutoff Valves C/I (3.9),
File 112872.8215 Series Normally Closed:1) Standard C22.2 No. 139 "Electrically Operated
Valves," File 10381.2) Automatic Gas Valves Z21.21 (6.5), File 112872.8215 Series Normally Open:1) Standard C22.2 No. 139 "Electrically Operated
Valves," File 10381. UL listed, as indicated. FM approved (Normally Closedonly, except Catalog Numbers 8215A090 and 8215A040).RedHat II meets applicable CE directives.Refer to Engineering Section for details.
Standard: RedHat II - Watertight, Types 1, 2, 3, 3S, 4, and 4X; RedHat - Type I.Optional: RedHat II - Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9; RedHat - Explosionproof and Raintight, Types 3, 7, and 9.(Except EF8215A40 and EF8215A90, which are suitable for Types 3 and 7(C and D) only and have a T2B temperature rating code.) To order, add prefix “EF” to catalog number. See Optional Features Section for other available options.
8040
Valve Parts in Contact with Fluids Body Aluminum
Seals, Diaphragms, Disc NBR
Disc-Holder PA (10.1 and 11.6 watt Normally Open only)
Core Guide CA
Core Tube 305 Stainless Steel
Rider Rings PTFE
Core and Plugnut 430F Stainless Steel
Springs* 302 Stainless Steel
Shading Coil Copper
* For 8040H006, 8040H007, 8040H008, spring material is 17-7 PH
StandardCoil andClass of
Insulation
Watt Rating and PowerConsumption Spare Coil Part No.
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz),6, 12, 24, 120, 240 volts DC. Must be specified when ordering. Other voltages available when required.
Electrical
Nominal Ambient Temp. Ranges
% ^ # )
7
Construction
SeriesAC DC
RedHat II/RedHat RedHat II RedHat
8040 -40˚F to 125˚F(-40˚C to 52˚C) - -
8215 32˚F to 125˚F(0˚C to 52˚C)
32˚F to 104˚F(0˚C to 40˚C)
32˚F to 77˚F(0˚C to 25˚C)
(104˚F/40˚C occasionally)Refer to Engineering Section for details.
� Do not use for Fuel Gas.� On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� FM Approved Process Control Valves. See Engineering Section (Approvals) for details.� Type I enclosure only.� � = Safety Shutoff Valve; � = General Purpose Valve. Refer to Engineering Section (Approvals) for details. � 1" W.C. Drop @ 2" W.C. Inlet Pressure, 1,000 Btu/cu.ft. or more, 0.64 Specific Gravity Gas.
� Do not use for Fuel Gas.� On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� FM Approved Process Control Valves. See Engineering Section (Approvals) for details.� Type 1 enclosure only.� � = Safety Shutoff Valve; � = General Purpose Valve. Refer to Engineering Section (Approvals) for details.� 1" W.C. Drop @ 2" W.C. Inlet Pressure, 1,000 Btu/cu.ft. or more, 0.64 Specific Gravity Gas.
9
Specifications (Metric units)
2/2SERIES80408215 4
2-WAY
Dimensions: inches (mm)
2 CORED HOLES.350 [8.9] DEEP FOR.164-32 TH’DFORMING SCREW
.800 [20.3]
.406 [10.3]
.60 [15]
BOTTOM VIEW OF BODY
NPTBOTH ENDS
R .088 [R 2.2]4 PLACES
LFLOW
.750 [19.1].115 [2.9] 2 PLACES
.90 [23] .250 [6.4]
K
PH
1/2 NPT
W
.97 [25]
IN
Const. Ref. 11
FLOW
L
P
NPTBOTH ENDS
H
W
Ø .88 [Ø 22]HOLE FOR1/2 CONDUITCONN.
Const. Ref. 12-15, 18-20
FLOW
NPTBOTH ENDS
L
K
P
H
W
1/2 NPT
1.66 [42]
2 MOUNTING HOLESØ .28 [Ø 7.1]
Const. Ref. 1-4, 9, 10, 13A, 13BConst.Ref. H K L P W
IMPORTANT: Valves may be mounted in any positionexcept all DC constructions and those marked �, whichmust be mounted with the solenoid vertical and upright.Constructions marked � must be mounted with the solenoid vertical and upright or horizontal only.
10
Const. Ref. 6, 7, 8, 16, 17
P
H
L
K
W
NPTBOTH ENDS
7/8 DIA HOLEFOR 1/2 CONDUIT CONN.
FLOW
2/2SERIES
8210
Features• Wide range of pressure ratings, sizes, and resilient
materials provide long service life and low internal leakage
• High Flow Valves for liquid, corrosive, and air/inert gas service
• Industrial applications include:- Car wash - Laundry equipment- Air compressors - Industrial water control- Pumps
Pilot OperatedGeneral Service Solenoid Valves
Brass or Stainless Steel Bodies3/8" to 2 1/2" NPT
NC
NO
Solenoid Enclosures
Electrical
Nominal Ambient Temp. RangesRedHat II/RedHat AC: 32˚F to 125˚F (0˚C to 52˚C)
RedHat II DC: 32˚F to 104˚F (0˚C to 40˚C)RedHat DC: 32˚F to 77˚F (0˚C to 25˚C)
(104˚F/40˚C occasionally)Refer to Engineering Section for details.
ApprovalsCSA certified. RedHat II meets applicable CE directives.Refer to Engineering Section for details.
Standard: RedHat II - Watertight, Types 1, 2, 3, 3S, 4, and 4X; RedHat - Type I.Optional: RedHat II - Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P,7, and 9; Red-Hat - Explosionproof and Watertight, Types 3, 4, 4X, 7, and 9.(To order, add prefix “EF” to catalog number, except Catalog Numbers 8210B057,8210B058, and 8210B059, which are not available with Explosionproof enclosures.)See Optional Features Section for other available options.
Construction
4 2-W
AY
11
% )
Valve Parts in Contact with Fluids
Body Brass 304 Stainless Steel
Seals and Discs NBR or PTFE
Disc-Holder PA
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs 302 Stainless Steel
Shading Coil Copper Silver
StandardCoil andClass of
Insulation
Watt Rating and PowerConsumption Spare Coil Part Number
� 5 psi on Air; 1 psi on Water. � Valves not available with Explosionproof enclosures.� Valve provided with PTFE main disc. � On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� Valve includes UItem (G.E. trademark) piston. AC construction also has PA seating. � Letter “D” denotes diaphragm construction; “P” denotes piston construction. No disc-holder.� � Safety Shutoff Valve; � General Purpose Valve. � Stainless steel disc-holder.Refer to Engineering Section (Approvals) for details. ‡ Must have solenoid mounted vertical and upright.
� 0.3 bar on Air; 0.0 bar on Water. � Valves not available with Explosionproof enclosures.� Valve provided with PTFE main disc. � On 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� Valve includes UItem (G.E. trademark) piston. AC construction also has PA seating. � Letter “D” denotes diaphragm construction; “P” denotes piston construction. No disc-holder.� � Safety Shutoff Valve; � General Purpose Valve. � Stainless steel disc-holder.Refer to Engineering Section (Approvals) for details. ‡ Must have solenoid mounted vertical and upright.
* DC dimensions slightly larger.IMPORTANT: Valves may be mounted in any position, except as noted in specifications table.
8210R1
2/2SERIES
82104 2-W
AY
15
Dimensions: inches (mm)
K
P
H
L
FLOW
NPTBOTH ENDS
7/8 DIA. HOLE FOR1/2 CONDUIT CONN.
1.625 [41.3]
W
1.656 [42]
.281 [7.1] DIA.2 MOUNTING HOLES
OPTIONAL MOUNTING BRACKET
Const. Ref. 10, 15, 24, 26-36
L
P
H
K
W
NPT BOTH ENDS
1/2 NPT
FLOW
IN
Const. Ref. 12, 16, 18
Const.Ref. H K L P W
30ins. 8.22 X 5.06 5.47 4.87
mm 209 X 129 139 124
31ins. 5.25 X 3.75 4.44 3.25
mm 133 X 95 113 83
32ins. 5.69 X 3.66 4.69 3.25
mm 145 X 93 119 83
33ins. 6.06 X 4.38 4.94 3.91
mm 154 X 111 125 99
34ins. 6.91 X 3.75 6.09 3.25
mm 176 X 95 155 83
35ins. 7.34 X 3.66 6.34 3.25
mm 186 X 93 161 83
36ins. 7.66 X 4.38 6.56 3.91
mm 1.95 X 111 167 99
37ins. 4.61 2.75 2.81 3.89 2.39
mm 117 70 71 99 61
38ins. 4.61 2.75 2.81 3.89 2.39
mm 117 70 71 99 61
39ins. 5.42 2.31 2.75 4.86 3.80
mm 138 59 70 123 97
40ins. 5.20 3.29 2.81 4.50 2.28
mm 132 83 71 114 58
41ins. 5.13 3.10 3.75 4.32 3.25
mm 130 79 95 110 83
42ins. 6.43 4.40 3.93 5.62 3.25
mm 163 112 100 143 83
43ins. 5.57 3.35 3.66 4.57 3.25
mm 142 85 93 116 83
44ins. 5.90 3.57 4.38 4.79 3.91
mm 150 91 111 122 99
45ins. 5.26 3.17 3.75 4.38 3.84
mm 134 81 95 111 98
46ins. 4.95 3.10 3.84 4.31 2.75
mm 126 79 98 110 70
47ins. 6.43 3.59 3.75 4.81 3.52
mm 163 91 95 122 90
48ins. 6.43 3.59 3.66 4.81 3.73
mm 163 91 93 122 95
49ins. 6.91 3.75 4.38 4.96 4.40
mm 176 95 111 126 112
50ins. 8.13 4.15 5.06 5.37 4.87
mm 207 105 129 136 124
51ins. 8.13 4.15 5.50 5.37 5.18
mm 207 105 140 136 132
IMPORTANT: Valves may be mounted in any position, except as noted in specifications table.
8210R1
2/2SERIES
8210 4
2-WAY
16
Dimensions: inches (mm)
NPTBOTH ENDS
K
P
H
L
FLOW
1/2 NPT
W
.281 [7.1] DIA.2 MOUNTING HOLES
1.66 [42]
SHOWING MOUNTING BRACKET ONLY
Const. Ref. 39
1/2 NPT
1.656 [42]
1.625 [41.32]
.281 [7.1] DIA.2 MOUNTING HOLES
OPTIONAL MOUNTING BRACKET
W
NPTBOTH ENDS
L
FLOW
K
P
H
Const. Ref. 40-51
8210R1
2/2SERIES
8223
Features• Rugged piston construction built to withstand pressure
ratings of 450 to 1500 psi
• Angle body design for high flows
• Ideal for high-pressure water applications, such as car washes
• Mountable in any position
Pilot OperatedHigh Pressure Solenoid Valves
Brass or Stainless Steel Bodies1/4" to 3/4" NPT
NC
Solenoid Enclosures
Electrical
Nominal Ambient Temp. RangesAC: 32˚F to 125˚F (0˚C to 52˚C) DC: 32˚F to 104˚F (0˚C to 40˚C)Refer to Engineering Section for details.
ApprovalsCSA certified. Meets applicable CE directives.Refer to Engineering Section for details.
Construction
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X.Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.(To order, add prefix “EF” to catalog number.) See Optional Features Section for other available options.
Brass Version
4 2-W
AY
21
% )
Valve Parts in Contact with Fluids Body Brass 300 Stainless Steel
Seals and Disc NBR, PA, PTFE PTFE, NBR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Core Spring 302 Stainless Steel
Shading Coil Copper Silver
StandardCoil andClass of
Insulation
Watt Rating and PowerConsumption Spare Coil Part Number
DCWatts
AC General Purpose Explosionproof
WattsVA
HoldingVA
Inrush AC DC AC DCF - 10.1 25 50 238610 - 238614 -
F 22.6 17.1 40 70 238610 238710 238614 238714
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).6, 12, 24, 120, 240 volts DC. Must be specified when ordering.Other voltages available when required.
8223R1
2/2SERIES
8223 4
2-WAY
22
Specifications (Metric units)
Specifications (English units)
Dimensions: inches (mm)
1/2 NPT
OUTLET
NPT2 PLACES
INLET LOCATED ON BOTTOM FORCAT. NO’S 8223G003, 005, 010, 012
% ^ # )Features• Reliable, proven design with high flows
• Small poppet valves for tight shutoff
• Wide range of elastomers for specialty service
• Mountable in any position
• Brass and stainless steel constructions
Direct ActingGeneral Service Solenoid Valves
Brass or Stainless Steel Bodies1/8" to 3/8" NPT
NC
NO
Solenoid Enclosures
Nominal Ambient Temp. RangesAC: 32˚F to 125˚F (0˚C to 52˚C) DC: 32˚F to 104˚F (0˚C to 40˚C)Refer to Engineering Section for details.
ApprovalsCSA certified. UL listed, as indicated. Normally ClosedValves FM approved. Meets applicable CE directives.Refer to Engineering Section for details.
Construction
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X.Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.(To order, add prefix “EF” to catalog number)See Optional Features Section for other available options.
8263
4 2-W
AY
29
Valve Parts in Contact with Fluids
Body Brass 303/304 Stainless Steel
Seals and Discs NBR or Cast UR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Springs 302 Stainless Steel
Shading Coil Copper Silver
Stem PA (Normally Open)
Note: All 1/8" NPT Normally Open valves contain CA. All 1/4" NPT Normally Openvalves contain PA.
StandardCoil andClass of
Insulation
Watt Rating and PowerConsumption Spare Coil Part No.
DCWatts
AC General Purpose Explosionproof
WattsVA
HoldingVA
Inrush AC DC AC DCF 10.6 6.1 16 30 238210 238310 238214 238314
F - 9.1 20 45 238210 - 238214 -
F 11.6 10.1 25 50 238610 238710 238614 238714
F 22.6 17.1 40 70 238610 238710 238614 238714
Standard Voltages: 24, 120, 240, 480 volts AC, 60 Hz (or 110, 220 volts AC, 50 Hz).6, 12, 24, 120, 240 volts DC. Must be specified when ordering.Other voltages available when required.
Electrical
8262_8263R1
2/2SERIES82628263 4
2-WAY
30
Specifications (English units)
PipeSize(ins.)
OrificeSize(ins.)
CvFlow
Factor
Operating Pressure Differential (psi)Max. FluidTemp. ˚F Brass Body Stainless Steel Body
Watt Rating/Class of CoilInsulation �Max. AC Max. DC
Air-InertGas Water
Lt. Oil@ 300SSU
Air-InertGas Water
Lt. Oil@ 300SSU AC DC
CatalogNumber
Const.Ref.
UL �Listing
CatalogNumber
Const.Ref.
UL �Listing AC DC
NORMALLY CLOSED (Closed when de-energized), NBR Disc
� Cast UR disc supplied as standard.� On 50 hertz service, the rating for the 6.1/F solenoid is 8.1 watts.� � Safety Shutoff Valve; � General Purpose Valve. Refer to Engineering Section (Approvals) for details.
8262_8263R1
2/2SERIES
826282634 2-
WAY
31
Specifications (Metric units)
PipeSize(ins.)
OrificeSize(mm)
Kv FlowFactor(m3/h)
Operating Pressure Differential (bar) Max.Fluid
Temp. ˚C Brass Body Stainless Steel Body
Watt Rating/Class of CoilInsulation �Max. AC Max. DC
Air-InertGas Water
Lt. Oil @ 300SSU
Air-InertGas Water
Lt. Oil @ 300SSU AC DC
CatalogNumber
Const.Ref.
UL �Listing
CatalogNumber
Const.Ref.
UL �Listing AC DC
NORMALLY CLOSED (Closed when de-energized), NBR Disc
� Cast UR disc supplied as standard.� On 50 hertz service, the rating for the 6.1/F solenoid is 8.1 watts.� � Safety Shutoff Valve; � General Purpose Valve. Refer to Engineering Section (Approvals) for details.
8262_8263R1
2/2SERIES82628263 4
2-WAY
32
Dimensions: inches (mm)
Const. Ref. 11-14, 16, 17
Const. Ref. 1
.44 [11]
.44[11]
.09 [2.3]FOR MOUNTING2 PLACES
2 MOUNTING HOLESFOR .164 [4] THREADCUTTING SCREW
.09 [2.3] 2 PLACES K
P
H
L
FLOW
1/2 NPT W
1/8 NPTBOTH ENDS
.64 [16]1.30 [33]
Const. Refs. 8
Const. Ref. 2, 4, 6, 9
Mounting Details
Const. Ref. 3, 5, 7
Const.Ref. H K L P W
1ins. 2.52 1.30 1.19 2.16 1.69mm 64 33 30 55 43
2ins. 2.98 1.71 1.56 2.57 1.69mm 76 43 40 65 43
3ins. 3.07 1.63 1.88 2.49 1.69mm 78 41 48 63 43
4ins. 3.20 1.78 1.56 2.79 1.95mm 81 45 40 71 50
5ins. 3.25 1.70 2.00 2.77 1.95mm 83 43 51 70 50
6ins. 3.16 1.78 1.56 2.75 1.95mm 80 45 40 70 50
7ins. 3.25 1.70 2.00 2.67 1.95mm 83 43 51 68 50
8ins. 3.15 1.32 1.19 2.18 1.69mm 80 34 30 55 43
9ins. 3.23 1.67 1.25 2.81 1.95mm 82 42 32 71 50
11ins. 2.94 1.71 1.56 2.57 1.69mm 75 43 40 65 43
12ins. 3.12 1.78 1.56 2.75 1.95mm 79 45 40 70 50
13ins. 3.12 1.78 1.56 2.75 1.95mm 79 45 40 70 50
14ins. 3.16 1.65 1.56 2.79 1.95mm 80 42 40 71 50
16ins. 3.01 1.73 1.25 2.59 1.69mm 76 44 32 66 43
17ins. 3.19 1.80 1.25 2.77 1.95mm 81 46 32 70 50
IMPORTANT: Valves may be mounted in any position.
8262_8263R1
42/2
SERIES
8030 2-W
AY
% ^ # )Features• Operate at low pressures: no minimum required; up
to 15 psi (1 bar) maximum differential
• Normally closed or normally open operation
• Widely used for dispensing, collating, gas shutoff,vacuum holding, and tank draining applications
• Normally open valve well suited for venting systems
Direct ActingLow Pressure Solenoid Valves
Brass or Stainless Steel Bodies3/8" to 3/4" NPT
NC
NO
Solenoid Enclosures
Nominal Ambient Temp. RangesAC: 32˚F to 125˚F (0˚C to 52˚C) DC: 32˚F to 104˚F (0˚C to 40˚C) Refer to Engineering Section for details.
ApprovalsCSA certified. UL listed, as indicated. FM approved(Normally closed only except 8030G017 and 8030G067).Meets applicable CE directives.Refer to Engineering Section for details.
Standard: Watertight, Types 1, 2, 3, 3S, 4, and 4X (all except 16.8 watt).Metal Type 1 General Purpose housing with 7/8" hole for 1/2" conduit hub (16.8 watt) Optional: Explosionproof and Watertight, Types 3, 3S, 4, 4X, 6, 6P, 7, and 9.(To order, add prefix “EF” to catalog number.)Note: Wattages 16.1 and 20.1 meet Type 7 Groups A, B, C, and D; and Type 9 Groups E and F only. See Optional Features Section for other available options.
Valve Parts in Contact with Fluids
Body Brass 304 Stainless Steel
Seals and Disc NBR
Core Tube 305 Stainless Steel
Core and Plugnut 430F Stainless Steel
Core Spring 302 Stainless Steel
Shading Coil Copper Silver
Stem PA (Normally Open)
StandardCoil andClass of
Insulation
Watt Rating and PowerConsumption Spare Coil Part Number
� On all 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� � = Safety Shutoff Valve; � = General Purpose Valve. Refer to Engineering Section (Approvals) for details.
PipeSize(ins.)
OrificeSize(mm)
Kv FlowFactor(m3/h)
Operating PressureDifferential (bar) Max. Fluid
Temp. ˚C
Brass Body Stainless Steel BodyWatt Rating/Class of CoilInsulation �
� On all 50 hertz service, the watt rating for the 6.1/F solenoid is 8.1 watts.� � = Safety Shutoff Valve; � = General Purpose Valve. Refer to Engineering Section (Approvals) for details.
Specifications (English units)
8030R1
2/2SERIES
80304 2-W
AY
5
Dimensions: inches (mm)
Const. Ref. 1, 2, 3
Const. Ref. 7, 8
Const.Ref. H K L P W
1ins. 3.85 3 1.91 3.41 1.69mm 98 76 49 87 43
2ins. 4 3.14 1.91 3.55 1.95mm 102 80 49 90 50
3ins. 4.07 3.25 2.28 3.63 1.69mm 103 83 58 92 43
7ins. 3.97 1.88 2.81 2.85 2.29mm 101 48 71 72 58
8ins. 3.97 1.88 2.81 2.85 2.29mm 101 48 71 72 58
9ins. 4.1 2.44 2.81 3.41 2.28mm 104 62 71 87 58
10ins. 4.16 2.47 2.81 3.44 2.28mm 106 63 71 87 58
11ins. 4.31 3.39 2.28 3.77 2.06mm 110 86 58 96 52
12ins. 4.16 1.1 1.91 3.72 2.06mm 106 28 49 94 52
13ins. 4.37 1.05 2.28 3.83 2.06mm 111 27 58 97 52
IMPORTANT: Valves may be mounted in any position,except for 8030G003 DC, which must be mountedwith the solenoid vertical and upright.