BACKFLOW PREVENTION
Prepared by
Catherine L. Morley, P.E.
8/10/2019 8-When All Else Fails Backflow Prevention
2/40
The Surcharged Sewer Problem
8/10/2019 8-When All Else Fails Backflow Prevention
3/40
WHEN MIGHT IT BE NEEDED?
8/10/2019 8-When All Else Fails Backflow Prevention
4/40
Common Situations
Geographical Low Point
8/10/2019 8-When All Else Fails Backflow Prevention
5/40
Bottom of the Hill
8/10/2019 8-When All Else Fails Backflow Prevention
6/40
Common Situations
Geographical Low Point
Influence of Pump Station Wet Well
Sewer Lateral Connects to Interceptor
8/10/2019 8-When All Else Fails Backflow Prevention
7/40
Common Situations
8/10/2019 8-When All Else Fails Backflow Prevention
8/40
Common Situations
Geographical Low Point
Influence of Pump Station Wet Well
Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge
8/10/2019 8-When All Else Fails Backflow Prevention
9/40
Downstream of Force Main Discharge
8/10/2019 8-When All Else Fails Backflow Prevention
10/40
Common Situations
Geographical Low Point
Influence of Pump Station Wet Well
Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge
Downstream Interceptor Exhibits Control
Reverse Flow
8/10/2019 8-When All Else Fails Backflow Prevention
11/40
Downstream Control
0
0.2
0.4
0.6
0.8
1
1.2
0 10 20 30 40 50 60 70 80 90
Flow(
MGD)
Depth of Flow (in)
8/10/2019 8-When All Else Fails Backflow Prevention
12/40
Common Situations
Geographical Low Point
Influence of Pump Station Wet Well
Sewer Lateral Connects to Interceptor Downstream of Force Main Discharge
Downstream Interceptor Exhibits Control
Reverse Flow Amid Foundation Drain Clusters
8/10/2019 8-When All Else Fails Backflow Prevention
13/40
BACKFLOW PREVENTION OPTIONS
8/10/2019 8-When All Else Fails Backflow Prevention
14/40
Backflow Prevention Options
Floor Plug
Stand Pipe
Backwater Valve Clean Check
Overhead Sewer
External Pump-Over (EverReady)
8/10/2019 8-When All Else Fails Backflow Prevention
15/40
Floor Plug / Stand-pipe
8/10/2019 8-When All Else Fails Backflow Prevention
16/40
Floor Plug / Stand-pipe
Pros
Cheapest options
Easily accessible
Cons
Effective up to 3 head
Need good seal with floor
Cannot use basement facilities whileoperating
8/10/2019 8-When All Else Fails Backflow Prevention
17/40
Floor Plug / Stand-pipe
8/10/2019 8-When All Else Fails Backflow Prevention
18/40
Backwater Valve
Internal installation shown
Can be installed externally butneeds access chamber
8/10/2019 8-When All Else Fails Backflow Prevention
19/40
Backwater Valve
Pros
Cheapest of the valve-type options ($2,000 -$4,000)
Easily accessible Cons
All drains need to connect prior to be effective
Should not be used if foundation drainconnected
Cannot use basement facilities while operating
8/10/2019 8-When All Else Fails Backflow Prevention
20/40
Clean Check
PVC THREADED PLUG
PVC FEMALE
ADAPTER
PVC RISER PIPE*
VALVE BODY
PVC INSERT PIPE
FLAPPER ASSEMBLY
FLAPPER
8/10/2019 8-When All Else Fails Backflow Prevention
21/40
Clean Check
Pros Relatively inexpensive ($2,500 - $6,000)
Low maintenance
Easily accessible
Also a cleanout
Cons
Cannot be used if foundation drainconnected
Minimal use of facilities while operating
Roto-rooter
8/10/2019 8-When All Else Fails Backflow Prevention
22/40
Before Overhead Sewer Installation
8/10/2019 8-When All Else Fails Backflow Prevention
23/40
After Overhead Sewer Installation
8/10/2019 8-When All Else Fails Backflow Prevention
24/40
Overhead Sewer
8/10/2019 8-When All Else Fails Backflow Prevention
25/40
Overhead Sewer
Pros
Full protection
May remove foundation drain from sanitary
system
Cons
Expensive ($7,000 - $15,000)
Requires battery back-up system for poweroutages
8/10/2019 8-When All Else Fails Backflow Prevention
26/40
External Pump-Over
8/10/2019 8-When All Else Fails Backflow Prevention
27/40
External Pump-Over
8/10/2019 8-When All Else Fails Backflow Prevention
28/40
External Pump-Over
Pros
Full protection
May remove foundation drain from sanitary
system
Cons
Very Expensive ($15,000 - $20,000)
Requires auxiliary generator for poweroutages
8/10/2019 8-When All Else Fails Backflow Prevention
29/40
LIMITATIONS
8/10/2019 8-When All Else Fails Backflow Prevention
30/40
Limitations
Maintenance Rags, check valve blockages, etc.
Power Outages (overhead systems)
Requires backup power supply or cannot usefacilities
Limited Facility Use (check valve systems)
Laundry and toilet overflows COSTS
8/10/2019 8-When All Else Fails Backflow Prevention
31/40
MUNICIPAL INVOLVEMENT
8/10/2019 8-When All Else Fails Backflow Prevention
32/40
Municipal Involvement
Education Benefits
Cost Sharing
Ordinance Changes
8/10/2019 8-When All Else Fails Backflow Prevention
33/40
8/10/2019 8-When All Else Fails Backflow Prevention
34/40
Overhead Sewer Conundrum
Current Basement Backups
Excess flow migrated upstream
8/10/2019 8-When All Else Fails Backflow Prevention
35/40
Benefits
Less Complaints Less Reporting to IEPA - SSOs
I/I Removal Through I/I Compliance
8/10/2019 8-When All Else Fails Backflow Prevention
36/40
Cost Sharing
Various Plans 50/50 up to max amount
Full cost up to a max amount
Higher reimbursement (or %) for FD removal
100% front with clawback
100% for at risk properties
Funding
Capital allocation Sewer surcharge
8/10/2019 8-When All Else Fails Backflow Prevention
37/40
Ordinance Changes
Any Backflow Prevention Building permit
I/I compliant
8/10/2019 8-When All Else Fails Backflow Prevention
38/40
Foundation Drain
8/10/2019 8-When All Else Fails Backflow Prevention
39/40
Ordinance Changes
Any Backflow Prevention Building permit
I/I compliant
Cost Sharing
Closing Ordinance Sump pump removal
Fines for reconnection
Teardown Policies I/I Compliance Remodeling Policies