Top Banner
RAILROAD COMMISSION OF TEXAS Oil and Gas Division API No. 42- 7. RRC District No. 8. RRC Lease No. Oil Well Potential Test, Completion or Recompletion Report, and Log LIN (WOLFCAMP) UNIVERSITY EAST EP ENERGY E&P COMPANY, L.P. 253385 4412VH ATTN CHELSEA CHAPMAN PO BOX 4660 HOUSTON, TX 77210-4660 12 , 44 , UL , A-U391 20 MILES NW DIRECTION FRO OZONA Initial Potential Reclass (Explain In remarks) Well record only Retest 11. Purpose of filing 6b. Distance and direction to nearest town in this county. 6a. Location (Section, Block, and Survey) 4. ADDRESS 9. Well No. RRC Operator No. 3. OPERATOR'S NAME (Exactly as shown on Form P-5, Organization Report) 2. LEASE NAME 1. FIELD NAME (as per RRC Records or Wildcat) 17576 7C 105-41873 CROCKETT 10. County of well site 5. If Operator has changed within last 60 days, name former operator X This facsimile W-2 was generated electronically from data submitted to the RRC. Tracking No.: 98125 Status: Submitted 12. If workover or reclass, give former field (with reservoir) & Gas ID or oil lease no. FIELD & RESERVOIR GAS ID or OIL LEASE # Oil-0 Gas-G Well # N/A 13. Type of electric or other log run 14. Completion or recompletion date Gamma Ray (MWD) 01/25/2014 SECTION I- POTENTIAL TEST DATA IMPORTANT: Test should be for 24 hours unless otherwise specified infield rules. 15. Date of test 16. No. of hours tested 17. Production method (Flowing, Gas Lift, Jetting, Pumping- Size & Type of pump) 18. Choke size 02/06/2014 24 Flowing 38/128 Oil - BBLS Oil - BBLS Gas - MCF Gas - MCF Water - BBLS Water - BBLS Gas - Oil Ratio Oil Gravity-API-60 o Flowing Tubing Pressure PSI PSI Casing Pressure 21. Was swab used during this test? 22. Oil produced prior to test (New & Reworked wells) 23. Injection Gas-Oil Ratio Yes No 19. Production during Test Period 20. Calculated 24- Hour Rate 596.0 1168 2717 1959 725.0 596.0 1168 2717 39.2 0.0 X 270.0 REMARKS: N/A INSTRUCTIONS: File an original and one copy of the completed FormW-2 in the appropriate RRC District Office within 30 days after completing a well and within 10 days after a potential test. If an operator does not properly report the results of a potential test within the 10-day period, the effective date of the allowable assigned to the well will not extend back more than 10 days before the W-2 was received in the District Office. (Statewide Rules 16 and 51) To report a completion or recompletion, fill in both sides of this form. To report a retest, fill in only the front side. WELL TESTERS CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I conducted or supervised this test by observation of (a) meter readings or (b) the top and bottom gauges of each tank into which production was run during the test. I further certify that the potential test data shown above is true, correct, and complete, to the best of my knowledge. Signature: Well Tester Name of Company RRC Representative OPERATOR'S CERTIFICATION I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was prepared by me or under my supervision and direction, and that data and facts stated therein are true, correct and complete, to the best of my knowledge. Telephone: Area Code Number Month Day Year Signature Title of Person Type or printed name of operator's representative Regulatory Analyst (713) 997-5138 02/24/2014 EP ENERGY E&P COMPANY, L.P. LINDA RENKEN
9

7C Oil Well Potential Test, Completion or Recompletion ...

Nov 28, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 7C Oil Well Potential Test, Completion or Recompletion ...

RAILROAD COMMISSION OF TEXAS Oil and Gas Division

API No. 42- 7. RRC District No.

8. RRC Lease No. Oil Well Potential Test, Completion or Recompletion Report, and Log

LIN (WOLFCAMP) UNIVERSITY EAST

EP ENERGY E&P COMPANY, L.P. 253385

4412VH

ATTN CHELSEA CHAPMAN PO BOX 4660 HOUSTON, TX 77210-4660

12 , 44 , UL , A-U391 20 MILES NW DIRECTION FRO OZONA

Initial Potential

Reclass

(Explain In remarks)Well record only

Retest

11. Purpose of filing

6b. Distance and direction to nearest town in this county.6a. Location (Section, Block, and Survey)

4. ADDRESS

9. Well No.

RRC Operator No.3. OPERATOR'S NAME (Exactly as shown on Form P-5, Organization Report)

2. LEASE NAME1. FIELD NAME (as per RRC Records or Wildcat)

17576

7C105-41873

CROCKETT10. County of well site

5. If Operator has changed within last 60 days, name former operator

X

This facsimile W-2 was generated electronically from data submitted to the RRC.

Tracking No.: 98125Status: Submitted

12. If workover or reclass, give former field (with reservoir) & Gas ID or oil lease no.FIELD & RESERVOIR

GAS ID or OIL LEASE #

Oil-0 Gas-G Well #

N/A

13. Type of electric or other log run 14. Completion or recompletion date

Gamma Ray (MWD) 01/25/2014

SECTION I- POTENTIAL TEST DATA IMPORTANT: Test should be for 24 hours unless otherwise specified infield rules. 15. Date of test 16. No. of hours tested 17. Production method (Flowing, Gas Lift, Jetting, Pumping- Size & Type of pump) 18. Choke size

02/06/2014 24 Flowing 38/128

Oil - BBLS

Oil - BBLS

Gas - MCF

Gas - MCF

Water - BBLS

Water - BBLS Gas - Oil Ratio

Oil Gravity-API-60 o

Flowing Tubing Pressure

PSI

PSI

Casing Pressure

21. Was swab used during this test? 22. Oil produced prior to test (New & Reworked wells) 23. Injection Gas-Oil RatioYes No

19. Production during Test Period

20. Calculated 24- Hour Rate

596.0 1168 2717 1959 725.0

596.0 1168 2717 39.2 0.0

X 270.0REMARKS: N/A

INSTRUCTIONS: File an original and one copy of the completed FormW-2 in the appropriate RRC District Office within30 days after completing a well and within 10 days after a potential test. If an operator does not properly report theresults of a potential test within the 10-day period, the effective date of the allowable assigned to the well will not extendback more than 10 days before the W-2 was received in the District Office. (Statewide Rules 16 and 51) To report acompletion or recompletion, fill in both sides of this form. To report a retest, fill in only the front side.

WELL TESTERS CERTIFICATIONI declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I conducted or supervised this test by observation of (a) meterreadings or (b) the top and bottom gauges of each tank into which production was run during the test. I further certify that the potential test data shownabove is true, correct, and complete, to the best of my knowledge.

Signature: Well Tester Name of Company RRC Representative

OPERATOR'S CERTIFICATIONI declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am authorized to make this report, that this report was preparedby me or under my supervision and direction, and that data and facts stated therein are true, correct and complete, to the best of my knowledge.

Telephone: Area Code Number Month Day Year Signature

Title of PersonType or printed name of operator's representativeRegulatory Analyst

(713) 997-5138 02/24/2014

EP ENERGY E&P COMPANY, L.P.

LINDA RENKEN

Page 2: 7C Oil Well Potential Test, Completion or Recompletion ...

DATA ON WELL COMPLETION AND LOG (Not Required on Retest)SECTION III

24. Type of Completion

New Well Deepening Plug Back Other

26. Notice of Intention to Drill this well was filed in Name of

DATE

PERMIT NO.

PERMIT NO.

PERMIT NO.

PERMIT NO.

CASE NO.

Other

Commenced Completed

31. Location of well, relative to nearest lease boundaries Feet From

Line of the

Line and Feet from

Lease

32. Elevation (DF. RKB, RT. GR ETC.) 33. Was directional survey made otherthan inclination (Form W-12)? Yes No

34. Top of Pay 35. Total Depth 36. P. B. Depth Dt. of Letter

Dt. of Letter

PermitWater Injection

PermitSalt Water Disposal

ExceptionRule 37DeepenPlug Back or

25. Permit to Drill,

Railroad Commission (Special)

Recommendation of T.D.W.R.

Same Lease &Reservoir30. Distance to nearest well,

in this lease28. Total number of acres

this field (reservoir) including this well27. Number of producing wells on this lease in

Operations:Workover or Drilling

29. Date Plug Back, Deepening,

Determined by37. Surface Casing

RulesField

38. Is well multiple completion?

Yes No

X

EP ENERGY E&P COMPANY, L.P.

96 50621.975

10/12/2013 12/04/2013 383.0

13415.0 South 15858.0West UNIVERSITY EAST

2703 GLX

MD:15228

X

76905208/30/2013

X 09/10/20137140 MD:15279

39. If multiple completion, list all reservoir names (completions in this well) and Oil Lease or Gas ID No.FIELD & RESERVOIR

GAS ID or OIL LEASE #

Oil-0 Gas-G Well #

N/A40. Intervals Drilled by:

RotaryTools

CableTools

41. Name of Drilling Contractor

Yes No

42. Is Cementing Affidavit Attached?

TYPE & AMOUNT CEMENT (sacks)

CASING RECORD (Report All Strings Set in Well)

SLURRY VOL. cu. ft.

HOLE SIZEDEPTH SETCASING SIZE WT #/FT. MULTISTAGETOOL DEPTH

TOP OFCEMENT

43.

XX

9039 5/8 CLASS C 460 12 1/4 0 934.7152795 1/2 CLASS H 2375 8 3/4 754 3882.0

LINER RECORD44.

Size Top Bottom ScreenSacks Cement

N/A

45. TUBING RECORD 46. Producing Interval (this completion) Indicate depth of perforation or open hole

From L1 7403Packer SetSize Depth Set To 15184 From70622 7/8 7079 ToFrom ToFrom To

47. ACID, SHOT, FRACTURE, CEMENT SQUEEZE. ETC.

Depth Interval Amount and Kind of Material Used

7403.0 15184.0 ADD PERFS W/3-1/8" GUN, 6 SPF, 60 DEGREE PHASE (30 SETS). FRAC 30 STAGES (SEE FRACFOCUS FOR DETAILS).

FORMATION RECORD (LIST DEPTHS OF PRINCIPAL GEOLOGICAL MARKERS AND FORMATION TOPS)48.

Formations FormationsDepth Depth

WFMPC (WOLFCAMP C) 6901.0 MD: 6938.0WFMPC1 7003.0 MD: 7064.0WFMPC_TOP_LZ 7073.0 MD: 7184.0REMARKS: UNIVERSITY EAST 4412VH. KOP = 6688'. AS DRILLED PLAT HAS BEEN REQUESTED AND WILL BE SUBMITTED ONCE RECEIVED.

Page 3: 7C Oil Well Potential Test, Completion or Recompletion ...
Page 4: 7C Oil Well Potential Test, Completion or Recompletion ...
Page 5: 7C Oil Well Potential Test, Completion or Recompletion ...
Page 6: 7C Oil Well Potential Test, Completion or Recompletion ...
Page 7: 7C Oil Well Potential Test, Completion or Recompletion ...

RAILROAD COMMISSION OF TEXASOil and Gas Division

FORM L-1 ELECTRIC LOGSTATUS REPORT

Instructions

When to File Form L-1: Where to File Form L-1:� with the appropriate Commission district office� with Forms G-1, W-2, and GT-1 for new and deepened gas, oil, and

geothermal wells

� with Form W-3 for plugged dry holes� when sending in a log which was held under a request for confidentiality and the period for confidentiality has not yet expired.

Filling out Form L-1:� Section I and the signature section must be filled out for all wells� complete only the appropriate part of Section II

Type of log required:When is Form L-1 NOT required:

� with Forms W-2, G-1, and GT-1 filed for injection wells, disposal wells, water supply wells, service wells, re-test wells, re- classifications, and plugbacks of oil, gas or geothermal wells� with Form W-3 for plugging of other than a dry hole

� any wireline survey run for the purpose of obtaining lithology, porosity, or resistivity information� no more than one such log is required but it must be of the subject well� if such log is NOT run on the subject well, do NOT substitute any other type of log; just select Section II, Part A below

This facsimile L-1 was generated electronically from data submitted to the RRC.

SECTION I. IDENTIFICATIONOperatorName:

District No.

CompletionDate:

Drilling PermitNo.

FieldName

LeaseName

County

Lease/IDNo.

WellNo.

API

No. 42-SECTION II. LOG STATUS (Complete either A or B)

7C 01/25/2014

CROCKETT

769052LIN (WOLFCAMP)

EP ENERGY E&P COMPANY, L.P.

UNIVERSITY EAST 17576 4412VH

105-41873

A. BASIC ELECTRIC LOG NOT RUN

B. BASIC ELECTRIC LOG RUN. (Select one)

1. Confidentiality is requested and a copy of the header for each log that has been run on the well is attached.

2. Confidentiality already granted on basic electric log covering this interval (applicable to deepened wells only).

3. Basic electric log covering this interval already on file with Commission (applicable to deepened wells only).

4. Log attached to (select one):

(a) Form L-1 (this form). If the company/lease name on log is different from that shown in Section I, please enter name on log here:

Check here if attached log is being submitted after being held confidential.

(b) Form P-7, Application for Discovery Allowable and New Field Designation.

(c) Form W-4, Application for Multiple Completion:

Well No(s).

Signature Title

Name (print) Phone Date

-FOR RAILROAD COMMISSION USE ONLY-

X

X

X

02/24/2014

Lease or ID No(s).

Regulatory Analyst

(713) 997-5138

LINDA RENKEN

EP ENERGY E&P COMPANY, L.P.

Tracking No.: 98125

Page 8: 7C Oil Well Potential Test, Completion or Recompletion ...

STATEMENT OF PRODUCTIVITY OF ACREAGE ASSIGNED TO PRORATION UNITS Form P-15

The undersigned states that he is authorized to make this statement; that he has knowledge of the

OPERATOR

LEASE

,

, No.WELL

facts concerning the

; that such well is

completed in the Field, County,

Texas and that the acreage claimed, and assigned to such well for proration purposes as

authorized by special rule and as shown on the attached certified plat embraces

acres which can reasonably be considered to be productive of hydrocarbons.

- CERTIFICATE -

I declare under penalties prescribed in Sec. 91.143, Texas Natural Resources Code, that I am autho-rized to make this report, that this report was prepared by me or under my supervision and direction,and that data and facts stated therein are true, correct, and complete, to the best of my knowledge,

Date 02/24/2014 Signature LINDA RENKEN

Telephone (713) 997-5138

AREA CODETitle Regulatory Analyst

EP ENERGY E&P COMPANY, L.P.

UNIVERSITY EAST 4412VH

CROCKETT

260.0

LIN (WOLFCAMP)

This facsimile P-15 was generated electronically from data submitted to the RRC.

Tracking No.: 98125

Page 9: 7C Oil Well Potential Test, Completion or Recompletion ...