Operation Manual 10Base-T Ethernet Converter AR-727CM Table of Contents 1. Introduction 1.1 Features ----------------------------------- 1 1.2 Specifications ----------------------------------- 1 1.3 Applications ----------------------------------- 1 2. Overview 2.1 Dimensions and mounting ----------------------------------- 2 2.2 LED Indicators ------------------------------------ 3 2.3 DIP Switch Settings ------------------------------------- 3 2.4 D-SUB Connector pin out ------------------------------------ 3 3. Configuration 3.1 Reset To Factory Default ----------------------------------- 4 3.2 DHCP Function ----------------------------------- 4 3.3 How to configure the IP address assigned to your AR-727CM device 5 3.3.1 Get IP address by using Net727i software ------------------------- 5 3.3.2 Get IP address by DHCP Server ----------------------------------- 8 3.3.3 Get IP address by Hyper-Terminal function of the Window ------- 10 2005/12/16
12
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 727CM_MU_EN

Operation Manual

10Base-T Ethernet Converter

AR-727CM

Table of Contents

1. Introduction 1.1 Features 1.2 Specifications

1.3 Applications 2. Overview

2.1 Dimensions and mounting 2.2 LED Indicators 2.3 DIP Switch Settings 2.4 D-SUB Connector pin out 3. Configuration

3.1 Reset To Factory Default 3.2 DHCP Function

3.3 How to configure the IP address assign 3.3.1 Get IP address by using Net727i so 3.3.2 Get IP address by DHCP Server 3.3.3 Get IP address by Hyper-Terminal

----------------------------------- 1 ----------------------------------- 1 ----------------------------------- 1

----------------------------------- 2 ------------------------------------ 3 ------------------------------------- 3 ------------------------------------ 3

----------------------------------- 4 ----------------------------------- 4 ed to your AR-727CM device 5 ftware ------------------------- 5 ----------------------------------- 8

function of the Window ------- 10 2005/12/16

Page 2: 727CM_MU_EN

1. Introduction

The AR-727CM is an Ethernet to Serial Device Communication Controller. It transparently routes the data between Ethernet Port and Serial Port. The Device Server can be used in any application that need Ethernet and with a serial communication port already.

1.1 Features - Support Serial Port Freeze Function for High Security Use - Support Lock Remote IP Function - Provide TCP/IP Server Stack and DHCP function - One asynchronous serial ports allow full-duplex, 8-bit, none parity data

transfers - Serial port hardware handshaking with CTS and RTS selectable - 10BASE-T NE2000 compatible Ethernet Controller - Provide 256 Bytes Serial Buffer and 256 Bytes of TCP Buffer - Auto Configuration of the IP and gateway addresses and subnet function - Watchdog Timer included - Remote Configuration Through Ethernet or Local Configuration via Serial

Port - DIP Switch Selectable for RS-485 or RS-232 Interface

1.2 Specifications

- Ethernet : 10Base-T NE2000 compatible - Serial Port : 2400~57600 bps, None Parity, 8 data, 1 stop bit - Environment : -20°C to +75°C - Power Suppiy (DC) : 9.0 ~ 24.0 VDC - Power Consumption : 1.5W (max) - Dimensions (mm) : 100 X 60 X 23 - Accessories : One DB9 Male Cable for RS-485/RS-232 and

Power - Software and Utility : Net727i Setup Program in Floppy Disk or

CDROM.

1.3 Applications Access Controller, Time Recorder, Industry Controller, etc.

1

Page 3: 727CM_MU_EN

2. Overview 2.1 Dimensions and mounting

DIP

-SW

RS-

485

RS-

232

5G

ND

Eth

erne

t Por

t

46

Rx

( Inp

ut )

Tx (

Out

put)

B ( -

)DB9

A (

+ )

3291

OFF

AC

T

RS-

485

RS-

232

RS-

485

RS-

232

DH

CP

Enab

le

RU

N M

ode

Set

up M

ode

Link

Pow

er

AR

-727

CM

OFFON

OFFON2

ON

OFF

OFF1 ON

ON

ON

OFF

ON

3 OFF

4

BU

SY

Ser

ial T

X

Ser

ial R

X

DC

-INS

eria

l Por

t

Pow

er D

C

Pow

er D

C

DH

CP

Dis

able

RES

ET

DIP

-SW

SO

YA

L

How to install:

Screw length must no longer than 6mm.

Remove Jumper if powered by External Adapter. Close Jumper if powered through DB9 (4,6).

2

Page 4: 727CM_MU_EN

2.2 LED Indicators AR-727CM’s top panel contains six LED indicators, as described in the following table.

LED Name LED Color LED Function Green Power is on. POWER

Off Power is off, or power error condition exits. Yellow Media is connected. Link

Off Media is not connected. Green 10 Mbps Ethernet connection. ACT

Off Ethernet cable is disconnected, or has a short. Red Configuration Setup. BUSY Off No.

Green Serial data is being received. Serial RX Off Serial data is not being received. Red Serial data is being transmitted. Serial TX Off Serial data is not being transmitted.

2.3 DIP Switch Settings

DIP Switch 1 2 3 4 RS-232 ON OFF

Serial Setup Mode Two Wire RS-485

ONOFF ON

RS-232 ON OFF Normal Run Mode and Networking Setup Two wire RS-485

OFFOFF ON

DHCP Enable (Auto IP Address Configuration) ON DHCP Disable (Auto IP Address Configuration) OFF

2.4 D-SUB Connector pin out

Function Pin Wire Color Type DATA (A +) 1 Blue Bi-direction Two Wire RS-485DATA (B -) 9 Green Bi-direction

Data Transmit 2 White Output Data Receive 3 Yellow Input Signal Ground 5 Brown

Request to send (RTS) 8 Gray Output

RS-232

Clear to Send (CTS) 7 Purple Input Power Source : V+ 6 Red Power Input Power Ground : V- 4 Black

Depend on JP1 Setting

3

Page 5: 727CM_MU_EN

AR-727CM has two way of power supply, one from power jack and one from DB9. In general usually, The Serial Device has DC power already, so AR-727CM can share the power with Serial Device. The DB9 pin-4 connect to Power Ground (V-), pin-6 Connect to Power Source (V+). If you power AR-727CM from Adapter, remove the jumper from JP1.

3. Configuration 3.1 Reset To Factory Default

Press RESET button more than 5 seconds, The BUSY LED will flash 5 times, then AR-727CM will restore to Factory Default value. DIPswitch is OFF, OFF, OFF, OFF position.

IP Address : 192.168.001.127 Gateway IP : 192.168.001.254 Subnet Mask : 255.255.255.000 Serial Port : 9600,N,8,1

TCP Port : 1621 Password : none

DIP Switch position

OFF, OFF, OFF, OFF

3.2 DHCP Function

AR-727CM support Auto Configuration of the

IP and gateway addresses and subnet mask function, but must make sure the DHCP Server is active. Switch DIP SW-4 to “ON” position then power cycle the Device. In begging state the ACT LED will flashing, After IP has got ACT LED will off and auto save the new IP address to EEPROM, Switch DIP SW-4 to “OFF” position and move DIP SW-1 to “ON” position then you can get the new IP from Serial port via Hyper terminal.

4

Page 6: 727CM_MU_EN

3.3 How to configure the IP address assigned to your AR-727CM device? 3.3.1 Get IP address by using Net727i software Usually, the network of some company don’t built-in the DHCP Server. Therefore, we can use the following method to get default IP address and modify it. The steps as follows: Step 1: Press RESET button more than 5 seconds, The BUSY LED will flash 5 times,

then AR-727CM will restore to Factory Default value. Step 2 Open explorer, click “My Network Places” and press right key to open Properties.

Ste

:

p 3: Click “Local Area Connection” and press right key to open Properties. Then double click Internet Protocol (TCP/IP) to open Properties.

5

Page 7: 727CM_MU_EN

Step 4: Click ”Use the following IP address” and enter IP address 192.168.001.64, Subnet mask 255.255.255.0

Step 5: Click “ok” to exit. Step 6: Install Net727i.exe into your PC and run Net727i.exe

(Start → Programs → soyal software → Net727i )

6

Page 8: 727CM_MU_EN

Step 7: Click “Get” to get default Local IP Address, Gateway, Netmask and TCP Port. Step 8: Change new address and parameters then click “write”.

Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.

Remark: (1) How to know PC’s IP Address? (Win98)

Start → execute → enter “winipcfg”. (2) How to know PC’s IP Address? (Win2000)

Start → Programs → Accessories → Command Prompt → C:\> ipconfig (3) Please see detailed parameter in next page:

Setting Value Notes NecessityLocal IP Address 192.168.001

.127 Defines own IP Address of the AR-727CM Required

Local Gateway IP Address

192.168.001.254

Defines the IP Address of the default gateway

Required

Local Subnet Mask

255.255.255.000

Defines the IP Address range for the local network segment

Required

TCP Port 1621 The TCP port that other devices must use to contact this device. To avoid conflicts with standard TCP ports.

Required

MAC Address 00.E0.4C.00.00.50

The MAC (Media Access Control) address is a unique identifier set at the factory.

-

Force Transmit time

5 Forces AR-727CM device’s TCP/IP protocol software to try to pack serial data received during the specified time into the same data frame.

Optional

Force Transmit Bytes

32 Defines the amount of data in the serial, Ethernet buffer at which the break condition will be generated and the contents of buffer will be sent out via the Ethernet port.

Optional

Lock Remote IP Address

- Allows contact with only the specified remote IP address.

Optional

Lock Serial Port (Free Run or Freeze Over)

- To avoid the hacker use this IP to intercept data when Remote IP Address doesn’t receive data.

Optional

Setup Password none Console password Optional Serial Port Speed 9600 Changes current baud rate of the

AR-727CM’s serial port (from 2400bps to 57600bps).

Required

TCP Auto Disconnect Time (Second)

60 This device automatically closes TCP connection if there is no TCP activity for the given time.

Optional

Serial Port Hardware Handshaking (RTS/CTS)

- An exchange of signal over specific wires which each device indicates its readiness to send or receive data.

Optional

DHCP - Selecting the enable option allows DHCP to automatically assign the AR-727CM’s IP address.

Optional

7

Page 9: 727CM_MU_EN

3.3.2 Get IP address by DHCP Server AR-727CM support Auto Configuration of the IP and gateway addresses and subnet

mask function, but must make sure the DHCP Server is active. The steps as follows: Step 1: Switch DIP Switch position to OFF, OFF, OFF, ON. Step 2: Power cycle the device Step 3: In begging state the ACT LED will flashing, after IP has got ACT LED will off and auto save the new IP address to EEPROM. Step 4: Switch DIP SW-4 to “OFF” position and move DIP SW-1 and SW-2 to “ON” position Step 5:To modify parameter on the AR-727CM through the Hyper-Terminal function of the Window. (Start → Programs → Accessories → Communication → Hyper Terminal) Step 6: Click “Hyper-Terminal”. Step 7: key-in any temporary name. Shown as follows: It is not important matter.

Step 8: Choose which COM port St and click OK to exit.

8

ep 9: Set Port Settings to 9600, 8, None, 1, None and click “OK” to save.

Page 10: 727CM_MU_EN

Step 10: AR-727CM already gets IP address now shown as follows: Note that save it after set all parameters.

Step 11: If AR-727CM connects to soyal controller, please switch DIP Switch position to OFF, OFF, ON, OFF to RS-485 RUN Mode.

9

Page 11: 727CM_MU_EN

3.3.3 Get IP address by Hyper-Terminal function of the Window Step 1: To get Default IP address on the AR-727CM through the Hyper-Terminal function of the Window. (Start → Programs → Accessories → Communication → Hyper Terminal)

Step 2: Click “Hyper-Terminal”. Step 3: key-in any temporary name.

Shown as follows: It is not important matter.

S

tep 4: Choose which COM port Step and click OK to exit.

10

5: Set Port Settings to 9600, 8, None, 1, None and click “OK” to save.

Page 12: 727CM_MU_EN

Step 6: AR-727CM already gets IP address now shown as follows:

Step 7: Please refer above item and enter item on the so that set all parameters.

Step 8: Note that enter item 6 on the to save parameter after finishing to

set parameter.

Step 9: If AR-727CM connects to soyal controller, please switch DIP Switch

position to OFF, OFF, ON, OFF to RS-485 RUN Mode.