MyDailyChoice, dba HempWorx 8840 West Russell Road, Suite 245 Las Vegas, NV 89148 Certificate ID: 65098-39 Client Sample ID: 71119T1-500-Cinnamon Matrix: Tincture/Infused Oil - Hemp Seed Oil Received: 9/18/19 Lot Number: Scan QR Code for authenticity Authorization: Signature: Date: 9/30/2019 Jon Podgorni, Lead Research Chemist ID Weight % Concentration (mg/mL) Analyst: LG Test Date: 9/25/2019 The client sample was analyzed for plant-based cannabinoids by Liquid Chromatography (LC). The collected data was compared to data collected for certified reference standards at known concentrations. 65098-CN CN: Cannabinoid Profile & Potency [WI-10-17 & WI-10-17-01] D9-THC 0.34 0.04 THCV ND ND CBD 14.95 1.66 CBDV 0.16 0.02 CBG 0.19 0.02 CBC 0.54 0.06 CBN <LOQ <0.01 THCA ND ND CBDA <LOQ <0.01 CBGA ND ND D8-THC ND ND exo-THC ND ND Total 1.81 16.30 Max THC 0.04 0.34 Max CBD 1.67 15.00 Ratio of Total CBD to THC 44.5:1 0% 1.7% Cannabinoids (wt%) Max THC (and Max CBD) are calculated values for total cannabinoids after heating, assuming complete decarboxylation of the acid to the neutral form. It is calculated based on the weight loss of the acid group during decarboxylation: Max THC = (0.877 x THCA) + THC. This calculation does not include other cannabinoid isomers (eg. D8-THC and exo-THC). ND = None detected above the limits of detection (LOD), which is half of LOQ. Limit of Quantitation (LOQ) = 0.01 wt% FM-10-10, Rev. 1, DCN:15-0003 Page 1 of 4 www.ProVerdeLabs.com
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
MyDailyChoice, dba HempWorx
8840 West Russell Road, Suite 245
Las Vegas, NV 89148
Certificate ID: 65098-39
Client Sample ID: 71119T1-500-Cinnamon
Matrix: Tincture/Infused Oil - Hemp Seed Oil
Received: 9/18/19
Lot Number:
Scan QR Code for authenticity
Authorization: Signature: Date:
9/30/2019Jon Podgorni, Lead Research Chemist
ID Weight % Concentration (mg/mL)
Analyst: LG Test Date: 9/25/2019
The client sample was analyzed for plant-based cannabinoids by Liquid Chromatography (LC). The collected data was compared to data collected for certified reference standards at known concentrations.
Total 1.81 16.30Max THC 0.04 0.34Max CBD 1.67 15.00
Ratio of Total CBD to THC 44.5:1
0% 1.7%Cannabinoids (wt%)
Max THC (and Max CBD) are calculated values for total cannabinoids after heating, assuming complete decarboxylation of the acid to the neutral form. It is calculated based on the weight loss of the acid group during decarboxylation: Max THC = (0.877 x THCA) + THC. This calculation does not include other cannabinoid isomers (eg. D8-THC and exo-THC). ND = None detected above the limits of detection (LOD), which is half of LOQ.
Limit of Quantitation (LOQ) = 0.01 wt%
FM-10-10, Rev. 1, DCN:15-0003 Page 1 of 4www.ProVerdeLabs.com
This test method was performed in accordance with the requirements of ISO/IEC 17025. These results relate only to the test article listed in this report. Reports may not be reproduced except in their entirety.
Symbol Analysis Results Units Limits*
65098-MB1
Status
MB1: Microbiological Contaminants [WI-10-09]
AC Total Aerobic Bacterial Count <100 CFU/g 100,000 CFU/g PASS
CC Total Coliform Bacterial Count <100 CFU/g 1,000 CFU/g PASS
EB Total Bile Tolerant Gram Negative Count <100 CFU/g 1,000 CFU/g PASS
YM Total Yeast & Mold <100 CFU/g 10,000 CFU/g PASS
Note: All recorded Microbiological tests are within the established limits.
Limits (µg/kg)Conc. (µg/kg)
Analyst: JFD Test Date: 9/20/2019
This test method was performed in accordance with the requirements of ISO/IEC 17025. These results relate only to the test article listed in this report. Reports may not be reproduced except in their entirety.
This test method was performed in accordance with the requirements of ISO/IEC 17025. These results relate only to the test article listed in this report. Reports may not be reproduced except in their entirety.
Test ID Analysis Results Units Limits*
65098-MB2
Status
MB2: Pathogenic Bacterial Contaminants [WI-10-10]
65098-ECPT E. coli (O157) Negative NA Non Detected PASS
65098-SPT Salmonella Negative NA Non Detected PASS
Note: All recorded pathogenic bacteria tests passed.
Analyst: RAS Test Date: 9/26/2019
The client sample was anlayzed for pesticides using Liquid Chromatography with Mass Spectrometric detection (LC/MS/MS). The method used for sample prep was based on the European method for pesticide analysis (EN 15662).
* Testing limits for ingestion established by the State of California: CCR, Title 16, Division 42, Chapter 5, Section 5313. ND indicates "none detected" above the lower limit of detection (LLD). Analytes marked with (*) indicate analytes for which no recovery was observed for a pre-spiked matrix sample.
FM-10-10, Rev. 1, DCN:15-0003 Page 3 of 4www.ProVerdeLabs.com
The client sample was analyzed by Head-Space Gas Chromatography (HS-GC). The collected data was compared to data collected for certified reference standards at known concentrations.
Compound CAS Amount Limit Status
65098-VC
VC: Analysis of Volatile Organic Compounds [WI-10-28]
1 2 RL
Propane 74-98-6 1,000 ppmND PASS100
Isobutane 75-28-5 1,000 ppmND PASS100
Butane 106-97-8 1,000 ppmND PASS100
Methanol 67-56-1 3,000 ppmND PASS100
Pentane 109-66-0 5,000 ppmND PASS100
Ethanol 64-17-5 5,000 ppmND *100
Acetone 67-64-1 5,000 ppmND PASS100
Isopropanol 67-63-0 5,000 ppmND PASS100
Acetonitrile 75-05-8 410 ppmND PASS100
Hexane 110-54-3 290 ppmND PASS100
Heptane 142-82-5 5,000 ppmND PASS100
1) ND = Not detected at a level greater than the Reporting Limit (RL).2) In ppm, based on USP recommended limits for residual solvents, adopted by the Massachusetts Department of Public Health for cannabis concentrates and extracts on 3/31/16. Butane/Propane limits are based on limits established for state of Colorado.(*) For ethanol, as many formulations contain flavorings based on ethanol extracts of natural products, no status has been assigned.
END OF REPORT
FM-10-10, Rev. 1, DCN:15-0003 Page 4 of 4www.ProVerdeLabs.com