Top Banner
Scotts Business Park, Bampton, Devon, GB, EX16 9DN T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E [email protected] W www.fraser-antistatic.co.uk 6000_DS_iss3 p1 6000 IONTUBE The 6000 Iontube is designed to be incorporated into pneumatic transport systems to neutralise the static electricity generated in this process. ANTI-STATIC BARS > Static neutralisation is supplied by Ionising Bars mounted in enclosures around the circumference of the Iontube. The number of Bars is determined by the diameter and length of the Iontube. > The Bars are individually connected to a connector box mounted on the Iontube. So if one bar is damaged, only that bar needs to be replaced. > Standard 6000 Iontubes use 1m long Jacob stainless steel tubes. These are available in a wide range of standard sizes with coupling devices for easy incorporation into existing pipe work, see www.jacob-tubing. com. > We can make Iontubes in other materials and sizes - please contact the factory with your requirements. The 6000 Iontube can increase dramatically the efficiency of dust and product separation in cyclones; it can eliminate static charge build-up in hoppers and collection systems, preventing blockages and handling problems. Construction: The Iontube consists of Fraser 1250 Ionising bars mounted into housings welded around the circumference of a stainless steel tube. The welding is airtight. Size: Fraser offers standard DIN pipe sizes with outside diameters of 50mm, 80mm, 100mm, 150mm, 200mm, 250mm, however different sizes can be made or alternatively we can use pipes supplied or specified by the customer to ensure complete system compatibility. Please see table on page 2. Cable from Connector Box to Power Unit: 2m of HT Cable is standard, unless otherwise specified. This determines the distance between the Iontube and the Power Unit. Power Unit: Used with a Fraser HP Power Unit which converts the mains voltage to approx. 5.5kV. It is current limited with a maximum current output of 5mA for safety. Specification
2

6000 IONTUBE - ATHEX · 6000 IONTUBE The 6000 Iontube is designed to be incorporated into pneumatic transport systems to neutralise the static electricity generated in this process.

Mar 14, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 6000 IONTUBE - ATHEX · 6000 IONTUBE The 6000 Iontube is designed to be incorporated into pneumatic transport systems to neutralise the static electricity generated in this process.

Scotts Business Park, Bampton, Devon, GB, EX16 9DN T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E [email protected] W www.fraser-antistatic.co.uk

6000_DS_iss3

p1

6000IONTUBE

The 6000 Iontube is designed to be incorporated into pneumatic transport systems to neutralise the static electricity generated

in this process.

ANTI-STATIC BARS

> Static neutralisation is supplied by Ionising Bars mounted in enclosures around the circumference of the Iontube. The number of Bars is determined by the diameter and length of the Iontube.

> The Bars are individually connected to a connector box mounted on the Iontube. So if one bar is damaged, only that bar needs to be replaced.

> Standard 6000 Iontubes use 1m long Jacob stainless steel tubes. These are available in a wide range of standard sizes with coupling devices for easy incorporation into existing pipe work, see www.jacob-tubing.com.

> We can make Iontubes in other materials and sizes - please contact the factory with your requirements.

The 6000 Iontube can increase dramatically the efficiency of dust and product separation in cyclones; it can eliminate static charge build-up in hoppers and collection systems, preventing blockages and handling problems.

Construction: The Iontube consists of Fraser 1250 Ionising bars mounted into housings welded around the circumference of a stainless steel tube. The welding is airtight.

Size: Fraser offers standard DIN pipe sizes with outside diameters of 50mm, 80mm, 100mm, 150mm, 200mm, 250mm, however different sizes can be made or alternatively we can use pipes supplied or specified by the customer to ensure complete system compatibility. Please see table on page 2.

Cable from Connector Box to Power Unit:

2m of HT Cable is standard, unless otherwise specified. This determines the distance between the Iontube and the Power Unit.

Power Unit: Used with a Fraser HP Power Unit which converts the mains voltage to approx. 5.5kV. It is current limited with a maximum current output of 5mA for safety.

Specification

ben
Rectangle
ben
Typewritten Text
ATHEX Industrial Suppliers www.athex.eu - [email protected] Tel: +32 (0)3 653 21 82
Page 2: 6000 IONTUBE - ATHEX · 6000 IONTUBE The 6000 Iontube is designed to be incorporated into pneumatic transport systems to neutralise the static electricity generated in this process.

Scotts Business Park, Bampton, Devon, GB, EX16 9DN T + 44 (0) 1398 331114 F + 44 (0) 1398 331411 E [email protected] W www.fraser-antistatic.co.uk

6000_DS_iss3

p2

Applications

Dimensions

Standard Sizes

Outside Diameter “A” Nominal Length of Tube “B”

Number and length of static eliminators

50mm 984mm 2 x 750mm

80mm 984mm 2 x 750mm

100mm 984mm 3 x 750mm

150mm 984mm 3 x 750mm

200mm 984mm 4 x 750mm

250mm 984mm 4 x 750mm

300mm 984mm 5 x 750mm

Static electricity is generated by the interaction between the products, the air and the inner walls of the transport system. Generally plastics and very dry products are more susceptible to static generation. While plastic pipes will produce more static electricity than metal pipes, it is the nature of the product being transported which determines the severity of the problem.

The static generation is a continuous process in the transport system - so positioning of the 6000 Iontube is important. It should be positioned just before the problem area to prevent re-generation of the charge.

A

984.0

A

+12

TO P/U

IONTUBE 250 X 1000LG

E6000-250-1000

DTITLE REVISION

MATERIAL

SCALE

DRAWING No.

5 6

C

DO NOT SCALESHEET 3 OF 3

B

A

1 2 3

C

IF IN DOUBT - ASK4 5

B

6

A

D

1 2

THIRDANGLE

3

PROJECTION

ALL SHARP EDGES AND CORNERS TO BE REMOVEDMACHINING TOLERANCES UNLESS OTHERWISE STATED

4

SPECIFICATION AND SYMBOLS TO BS308

ONE DECIMAL PLACE

SURFACE FINISHES TO BS1134

0-100mm100-500mmABOVE 500mm

±0.1mm±0.25mm±0.4mm±0.75mm

A3SCOTTS BUSINESS PARKBAMPTON, DEVON

EX16 9DNWWW.FRASER-ANTISTATIC.CO.UK

TEL: 44-(0) 1398 331114FAX: 44-(0) 1398 331411

1:6

A

984.0

A

+12

TO P/U

IONTUBE 250 X 1000LG

E6000-250-1000

DTITLE REVISION

MATERIAL

SCALE

DRAWING No.

5 6

C

DO NOT SCALESHEET 3 OF 3

B

A

1 2 3

C

IF IN DOUBT - ASK4 5

B

6

A

D

1 2

THIRDANGLE

3

PROJECTION

ALL SHARP EDGES AND CORNERS TO BE REMOVEDMACHINING TOLERANCES UNLESS OTHERWISE STATED

4

SPECIFICATION AND SYMBOLS TO BS308

ONE DECIMAL PLACE

SURFACE FINISHES TO BS1134

0-100mm100-500mmABOVE 500mm

±0.1mm±0.25mm±0.4mm±0.75mm

A3SCOTTS BUSINESS PARKBAMPTON, DEVON

EX16 9DNWWW.FRASER-ANTISTATIC.CO.UK

TEL: 44-(0) 1398 331114FAX: 44-(0) 1398 331411

1:6

B

There is a 6mm flange at each end.

ben
Rectangle
ben
Typewritten Text
ATHEX Industrial Suppliers www.athex.eu - [email protected] Tel: +32 (0)3 653 21 82