60' DECOMPRESSION CHAMBER Descripon Twin Lock Deck Decompression Chamber, pressure vessel for human occupancy (PVHO) for maximum operaon to 100 MSW or 10 Bar. The two locks are designated as entry lock and main lock. The Chamber is mounted on a steel skid with 2 viewports installed into the shell of the vessel and a Medical Lock fied to enable items to be past to and from the pressurized environment. The chamber is fied out with high quality brass and stainless-steel fings providing the necessary control and instrumentaon required to operate the chamber. The chamber is designed to operate via two LP air inlet sources these are designated as Primary Air and Secondary Air. From these two sources of air the chamber locks can be pressurized safely via the control panel instruments and valves. The control panel provides communicaons and electrical distribuon. Internally the chamber is fied with bunks and seang for the comfort of the occupants during decompression treatment. The chamber, O2 Supply Quad and the HP Compressor Bauer KAP 150 (32,4 m3/h) 220/330 Bar (Electric 11Kw) can be fied in 20 Container as a standalone unit. The Container is out fied with a penetrator plate in order to supply the chamber with Air and O2 from external sources. There is also a HP Compressor Bauer Mariner 320 (18 m3/h) 220/330 Bar (Diesel with Lombardini 24Hp) as a backup unit. MARINE & COMMERCIAL DIVING SERVICES 38 Akti St. Koundourou 72100 Agios Nikolaos, Crete, Greece Tel. Greece: +30 28410 22770, Mob: +30 6944 126846 E-mail: [email protected], www.mardive.gr [email protected] www.mardive.gr
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
60' DECOMPRESSION CHAMBER
Descrip�on
Twin Lock Deck Decompression Chamber, pressure vessel for human occupancy (PVHO) for maximum opera�on to 100 MSW or
10 Bar. The two locks are designated as entry lock and main lock. The Chamber is mounted on a steel skid with 2 viewports installed
into the shell of the vessel and a Medical Lock fi�ed to enable items to be past to and from the pressurized environment. The
chamber is fi�ed out with high quality brass and stainless-steel fi�ngs providing the necessary control and instrumenta�on
required to operate the chamber. The chamber is designed to operate via two LP air inlet sources these are designated as Primary Air
and Secondary Air. From these two sources of air the chamber locks can be pressurized safely via the control panel instruments and
valves. The control panel provides communica�ons and electrical distribu�on. Internally the chamber is fi�ed with bunks and
sea�ng for the comfort of the occupants during decompression treatment.
The chamber, O2 Supply Quad and the HP Compressor Bauer KAP 150 (32,4 m3/h) 220/330 Bar (Electric 11Kw) can be fi�ed in 20
� Container as a standalone unit. The Container is out fi�ed with a penetrator plate in order to supply the chamber with Air and O2
from external sources. There is also a HP Compressor Bauer Mariner 320 (18 m3/h) 220/330 Bar (Diesel with Lombardini 24Hp) as a
backup unit.