Top Banner
6 April 2004 1 PXL-500/-510 Tiger Controller II
54

6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

Jan 15, 2016

Download

Documents

Christal Sutton
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 1

PXL-500/-510

Tiger Controller II

Page 2: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 2

The PXL-500 Controller

• Manages up to 65,535 cardholders

• Buffers up to 3,640 events– Events stored in FIFO

(First-In-First-Out) order

Page 3: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 3

The PXL-500 Controller

• Controller addressing via push-button and LEDs

• NO dip switches to set

Page 4: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 4

The PXL-500 Controller

• Auto configuration:– Doors software

automatically downloads controller/network information - no manual data entry

– Controller network termination

Page 5: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 5

The PXL-500 Controller

• Auto configuration:– Controller

communication mode (direct connect, modem, Ethernet)

– SB-593 Satellite board installation

Page 6: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 6

The PXL-500 Controller

• Inputs and Outputs are transient protected

• Handles either– 1 or 2 Readers for single

door In/Out controlOR

– Two doors using optional SB-593 Satellite board

Page 7: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 7

Power Specifications

• Power - 12 VDC @ 1 A– Worst case current draw – with all features

and options active

• Current Draw– 120 mA for the PXL-500– 150 mA for an SB-593– 50 mA to 200 mA dependent upon reader type1

– 200 mA for a LAN-500

• Relay Contact Rating - 1A @ 24 VDC

1 – Wiegand readers may draw more current, refer to the reader’s manual for specifics

Page 8: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 8

Wiring Specifications

• RS-232 Serial Communication Cable– 3 conductor, shielded, stranded, AWG-24

50 feet maximum run length (per RS-232 spec)

• RS-485 Controller Network Cable– 1-pair, twisted, shielded, stranded, AWG-24

16,000 feet total network run length

Page 9: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 9

Wiring Specifications

• Controller Power– 2 conductor, stranded, AWG-18– 200 feet maximum run length

• Earth Ground– Single conductor, AWG-18 (or larger gauge)– Minimize run length for best grounding conditions

Page 10: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 10

Wiring Specifications

• Input and Output Lines– 2 conductor, stranded, AWG-22– 500 feet maximum run length

• Readers– 6 conductor, shielded, stranded (for Keri Prox)– 4 to 7 conductor, shielded, stranded

(for Wiegand, by reader type)– MS-3000, MS-4000, MS-5000

• 500 feet maximum run length with AWG-24

– MS-7000• 500 feet maximum run length with AWG-20

Page 11: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 11

Typical Application Diagram

Page 12: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 12

Block Diagram - Communication

RS-485ControllerNetwork

RS-232PC to

MasterController

LAN-500Ethernet

PXL-510Alarm Panel

PXL-510Serial Port

Page 13: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 13

Block Diagram

ReaderConnections

EE Prom

UnitProtection

Page 14: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 14

Block Diagram

AddressLED

Battery

StatusLEDs

Page 15: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 15

Controller Block Diagram

Unit Power

Inputsand

Outputs

SelectionSwitch

Page 16: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 16

PCB Features

• Microprocessors

– CPU to manage controller general operation

– RISC* processor to manage I/O processing

– RISC* processor to manage the Reader receivers

* (Reduced Instruction Set Computer )

Page 17: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 17

PCB Features

• Socketed EE Prom and PIC– Quick, easy firmware

updates

• Battery– 5-year, Lithium

Page 18: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 18

PCB Features

• Quick disconnect terminals for all wiring connections

• Unique RS-485 connector– easily distinguish

network connectionfrom other connections

• Red power connector– easily distinguish power

from other connections

Page 19: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 19

Certifications

• CE Declaration of Conformity

• C-Tick

• CSA C22.2 No. 142

• UL 508 Part XVII

• FCC

Page 20: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 20

Communications - PC to Master Controller

• RS-232 serial port (TB-12)– Controller automatically

detects connection type

Page 21: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 21

Communications - PC to Master Controller

– Via direct serial connection

OR

– Via a pair of modems

Page 22: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 22

Communications - PC to Master Controller

• Optional, plug-in TCP/IP module (TB-13)– Controller automatically detects TCP/IP connection– Jumpers reconfigure communication

Page 23: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 23

Communications - Inter-Controller Network

• RS-485 serial port (TB-1)– Auto-configuration of network termination– Total network length up to 16,000 feet– Network configuration flexibility

• “T” and “star” configurations

– Single, twisted-pair, shielded cable– Link up to 128 controllers and 256 doors

Page 24: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 24

Communications - Options

• PXL-510 – with second serial COM port– Used as the Alarm Panel interface (TB-11), connecting to

Caddx NX8E alarm panels

Page 25: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 25

Inputs

• Inputs (TB-4)– Door Status– Request to Exit– Global Unlock (1)

or– Aux/Secondary RTE (2)

(1) Master controller only

(2) Master or slave controllers

Page 26: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 26

Outputs

• Form-C Output Relays (TB-3)– Door Lock– Alarm

• In a Form-C relay, the common always creates a complete circuit with either– The normally-open

contactOR

– The normally-closed contact

Page 27: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 27

Readers

• 2 Reader ports per Controller

• Controls either 1 or 2 doors– In / Out control of 1 door– 2-door control with

optional SB-593 board

Page 28: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 28

Readers - PXL-500P

• Exclusively for MS-Series Proximity Readers– MS-3000– MS-4000– MS-5000– MS-7000

A-Reader: Single Door, In Door, or Door 1 (TB-5)

B-Reader: Out Door or Door 2with SB-593 (TB-6)

Page 29: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 29

Readers - PXL-500W

• For Wiegand compatible reader technologies– Pyramid Associates

Readers (P-300, P-400, P-500, P-600, P-700)

– Bar code, mag-stripe, biometric, etc.

A-Reader: Single Door, In Door, or Door 1 (TB-5)

B-Reader: Out Door or Door 2with SB-593 (TB-6)

Page 30: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 30

Readers - PXL-500W

• Warning LED (LED-10)– Lights when 12 VDC is selected (as shown in picture)– Protects 5 VDC readers from over-voltage condition

• Jumper selectable (JP-5) for either 5 or 12 VDC Wiegand readers (5 VDC is the factory setting)

Page 31: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 31

Unit Addressing

• LED Display– Address displayed via easy-to-read

LEDs– Provides diagnostic information– Displays over or under supply voltage

value

Page 32: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 32

Unit Addressing

• Selection Button (S1)

– Set unit address• no DIP or rocker switches

• no PC pre-configuring

– Select diagnostic options

Page 33: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 33

Unit Reset

• Reset Jumper (JP3)– Clears unit memory and resets unit– Used in conjunction with S1

Page 34: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 34

Master versus Slave Operation

• Master Controller– Must be assigned address “01”– Manages communication between host PC

and the controller network– Handles presentation card enrollment (using

A-Reader), Show Photo, and ID Card features

• Slave Controllers– Can be assigned any other unique address

from “02” to “128”– Do not have to be addressed in sequential order

Page 35: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 35

Status LEDs

• TXD and RXD for RS-232– LEDs 2 and 3 for primary

serial port– LEDs 4 and 5 for optional

serial port– LEDs flicker red/green as

data is transferred

Page 36: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 36

Status LEDs

• Lock Relay– Lights when relay is active

• Alarm Relay– Lights when relay is active

Page 37: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 37

Status LEDs

• Power– Lights GREEN when power

is ON and OK– Lights RED when power is

over or under specification

• Communications for RS-485– Flickers red/green as data is

transferred

Page 38: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 38

System Protection

• The PXL-5xx controller has the following system protection features:– Metal-oxide Varistors– Transorbs– Gas Discharge Tube– Fused over/under voltage detection– Power status LEDs– Socketed RS-485 IC

Page 39: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 39

System Protection

• Power Status (Fuse) LED– Warns the installer of

unsafe power conditions– Glows RED if power is

reversed– Glows GREEN if there

is a power line short or an over current draw condition

Page 40: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 40

System Protection

• Gas Discharge Tube– Protect the PCB from

damage caused by transients and power surges

• MOVs – Protect relays from

damage caused by transients and power surges

Page 41: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 41

System Protection

• Socketed RS-485 communication IC– For quick repair of

damage caused by voltage spikes

Page 42: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 42

System Protection

• Thermal Fuse opens under unsafe power or current conditions

• CAUTION – Do not touch this component, it is very hot during operation

Page 43: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 43

System Protection

• Transorbs protect all signal inputs from damage caused by transients and power surges

Page 44: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 44

Environmental Operating Range

• Temperature– 0° to 140 °F (-18° to 60° C)

• Humidity– 0% to 90% relative humidity, non-condensing

Page 45: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 45

SB-593 Satellite Expansion Board

• Jumper selectable for either:– Second door control with

2 programmable outputs and 6 programmable inputs

OR– 4 programmable outputs

and 8 programmable inputs

• Uses Form C relays

Page 46: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 46

SB-593 Satellite Expansion Board

• Snaps into place on the PXL-500 controller– align header connectors

and plastic mounting pins to corresponding locations on controller and press into place

• Installation LEDs– indicates correct board

installation

Page 47: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 47

SB-593 Satellite Expansion Board

• Controller auto-detects an installed SB-593– no additional

configuration needed

• Status LEDs– Indicate relay

active/inactive status

• Relay Contact Rating– 1A @ 24 VDC

Page 48: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 48

Options - LCD-1

• LCD-1 - plug-in liquid-crystal display for:– Firmware revision– Date and time– Diagnostic information

Page 49: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 49

Options - LAN-50/100/500

• Provides low cost TCP/IP communication using either:– LAN-50/100 external modules– LAN-500 plug-in module

• IT experience required for proper configuration of LAN device

Page 50: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 50

Options - Alarm Panel Interface

• Fully integrated access and alarm panel control using the secondary serial port on the PXL-510 panel

• Interfaces with the Caddx NX-8E alarm panel

Page 51: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 51

Options - Alarm Panel Interface

• Use Doors software to: – Easily manage access

and alarm panel users– Report alarm system

activity

• Arm/disarm alarm system using access system Readers

Page 52: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 52

Options - Video Badging

• Fully integrated access control and badging

• Design and print badges with photos and custom graphics

• Keri also offers a Badging Service

Page 53: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 53

Options - Video Badging

• Single database entry point for user access and badging information

• On-demand badge holder photo display

Page 54: 6 April 20041 PXL-500/-510 Tiger Controller II. 6 April 20042 The PXL-500 Controller Manages up to 65,535 cardholders Buffers up to 3,640 events –Events.

6 April 2004 54

Integrated Telephone Entry

• Entraguard Gold– Fully integrated access control and telephone entry using

Keri’s Entraguard product line– Easily manage access and telephone entry users via Keri’s Doors software

– Either in radiant keypad or mechanical keypad versions