Top Banner
Gain Monitor ing System 28 th Feb. 2008 KOBE Hiroko Ikeda
7

Gain Monitoring System

Jan 02, 2016

Download

Documents

jonah-henson

Gain Monitoring System. 28 th Feb. 2008 KOBE Hiroko Ikeda. Status. 0.8mm thick, 10mm width, and flat acrylic plate is considered to be the best. Fiber distribution has been done. Now trying the system with two layers (twin, as follows). With only 1 layer. Acrylic plate (27.0cm long). - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: Gain Monitoring System

Gain Monitoring System

28th Feb. 2008

KOBE Hiroko Ikeda

Page 2: Gain Monitoring System

Status• 0.8mm thick, 10mm width,

and flat acrylic plate is considered to be the best.

• Fiber distribution has been done.

• Now trying the system with two layers (twin, as follows)

With only 1 layer

LEDAcrylic plate (27.0cm long)

Page 3: Gain Monitoring System

Fiber Distribution

Clear fiberThere are 20 fibers per a bundle.

LED direction toward each fiber varies.

Amount of LED light greatly depends on the direction.

Compared Np.e. of the ‘closest’ fiber to the light axis with one of the ‘farthest’.

ADC distribution of the ‘closest’ ADC distribution of the ‘farthest’

●:nearest

●:farthest

Vbias:77.0V

LED width:20ns

●:closest

●:farthest12.12%

6.318%

Page 4: Gain Monitoring System

Double Distance (No fiber)2 layers adjoin

Black: Noise (w/o LED) Red: w/ LED Np.e. can be calibrated.

2.853%

Page 6: Gain Monitoring System

Tracing Paper• In order to reduce the dispersion due to the LED direction,

pinched the tracing paper between LED and fiber.

Tracing paper (40g/m ) 2

●:farthest, w/o tracing paper 35.25%

■:farthest, w/ tracing paper 57.66%

▲:closest, w/o tracing paper 38.50%

▼:farthest, w/ tracing paper 41.43%

Page 7: Gain Monitoring System

Summary & Plans• Np.e. depends on which fiber we use.• Np.e. of the scintilator far from the LED is very small. (Ab

out half of the signal is dark noise. )• There isn’t a significant difference between direct and fib

er in the latter 9cm.• Tracing paper isn’t effective. Need something thicker.

• Determine the number of CMB by this weekend.