DRAWING SCHEDULE A00 A01 A02 A03 A04 A05 A06 COVER PAGE SITE PLAN DEMOLITION FLOOR PLAN FLOOR PLAN ROOF PLAN ELEVATIONS ELEVATIONS LOCATION PLAN ALTERATIONS AND ADDITIONS at 52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249 for A JONES GENERAL NOTES : IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OF AUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BE IN STRICT COMPLIANCE WITH COUNCIL LAWS, REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS & REGULATIONS REFER ALSO TO THE GENERAL REQUIREMENTS PAGE. SITE CLASSIFICATION : CLIMATE ZONE: SCALE @ A3 27/10/2021 PRINT DATE: PROJECT NUMBER: SCALE: IF IN DOUBT ASK 7 N2 ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE ENGINEERING DRAWINGS AND SPECIFICATIONS. THE DESIGNER SHALL BE NOTIFIED OF ANY DISCREPANCIES WITH THE DRAWINGS. THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECT SETOUT OF ALL WORKS. A LAND SURVEYOR IS RECOMMENDED BY THE DESIGNER FOR ALL SETOUT. USE FIGURED DIMENSIONS IN PREFERENCE TO SCALED DIMENSIONS. ALL FITTINGS & FIXTURES INSTALLED SHALL BE PURCHASED AS NEW CONDITION & QUALITY & CARRY THE RELEVANT AUSTRALIAN STANDARD COMPLIANCES. THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIG REFERRAL FOR LOCATIONS OF ALL UNDERGROUND SERVICES PRIOR TO COMMENCING ANY EARTHWORKS. THE BUILDER SHALL SECURE AND MAKE SAFE THE WORKSITE IN ACCORDANCE WITH WORK SAFE TASMANIA & WHS GUIDELINES & REGULATIONS. THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THE PROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTO THE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITE WORKS. 21084 BUSHFIRE ATTACK LEVEL: ALPINE AREA: N/A PROJECT INFORMATION: WIND REGION: A3 TERRAIN CLASSIFICATION: FLOOR AREAS: LAND TITLE, VOLUME & FOLIO SITE OVERLAYS: SCENIC MANAGEMENT COUNCIL: LAUNCESTON SITE AREA: SCHEME / ZONE: GENERAL RESIDENTIAL L . M . DELL LIC . No . CC 5932 G Level 2, 93 York Street, Launceston Tasmania, 7250. Tel - 6388 9287 - Mob - 0400 655 771 Email - [email protected]ABN 23 269 055 701 DRAWING No: REV: 1 of 7 A00 ISSUE: 0 APPROVAL rev. Amendment Date WIND SPEED MODERATE CORROSION ENVIRONMENT T2 EXEMPT 90479/29 655m2 NEW DECK AREA - 24.13m 2 EXISTING DWELLING FLOOR AREA - 117.62m 2 NEW CARPORT AREA - 17.5m 2 PLANNING EXHIBITED DOCUMENTS Planning Administration DA 0641/2021 Ref. No: Date advertised: 06/11/2021 This document is subject to copyright and is protected by law. In displaying this document on its website the Council grants website users a non-exclusive licence to reproduce the document in their web browser for the sole purpose of viewing the content. The Council reserves all other rights. Documents displayed on the Council's website are intended for public perusal only and should not be reproduced without the consent of the copyright owner.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
ALTERATIONS AND ADDITIONSat 52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
for A JONES
GENERAL NOTES:
IN ACCORDANCE WITH THE N.C.C.S BUILDING CODE OFAUSTRALIA VOLUME TWO, ALL BUILDING WORK SHALL BEIN STRICT COMPLIANCE WITH COUNCIL LAWS,REFERENCED AUSTRALIAN STANDARDS, BUILDING ACTS ®ULATIONS REFER ALSO TO THE GENERALREQUIREMENTS PAGE.
SITE CLASSIFICATION : CLIMATE ZONE:
SCALE @ A3 27/10/2021PRINT DATE: PROJECT NUMBER:SCALE: IF IN DOUBT ASK
7
N2
ALL DRAWINGS SHALL BE READ IN CONJUNCTION WITHTHE ENGINEERING DRAWINGS AND SPECIFICATIONS.THE DESIGNER SHALL BE NOTIFIED OF ANYDISCREPANCIES WITH THE DRAWINGS.
THE BUILDER SHALL BE RESPONSIBLE FOR THE CORRECTSETOUT OF ALL WORKS. A LAND SURVEYOR ISRECOMMENDED BY THE DESIGNER FOR ALL SETOUT.USE FIGURED DIMENSIONS IN PREFERENCE TO SCALEDDIMENSIONS.
ALL FITTINGS & FIXTURES INSTALLED SHALL BEPURCHASED AS NEW CONDITION & QUALITY & CARRYTHE RELEVANT AUSTRALIAN STANDARD COMPLIANCES.
THE BUILDER SHALL CARRY OUT DIAL BEFORE YOU DIGREFERRAL FOR LOCATIONS OF ALL UNDERGROUNDSERVICES PRIOR TO COMMENCING ANY EARTHWORKS.
THE BUILDER SHALL SECURE AND MAKE SAFE THEWORKSITE IN ACCORDANCE WITH WORK SAFETASMANIA & WHS GUIDELINES & REGULATIONS.
THE BUILDER SHALL INSTALL SILT TRAPS & SCREENS AT THEPROPERTY BOUNDARY TO PREVENT SILT RUNOFF INTOTHE COUNCIL MAIN SYSTEM FOR THE DURATION OF SITEWORKS.
90479/29655m2NEW DECK AREA - 24.13m2EXISTING DWELLING FLOOR AREA - 117.62m2
NEW CARPORT AREA - 17.5m2
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
SURFACE AND SUBSURFACE DRAINAGE SYSTEMSIN ACCORDANCE WITH PART D2. NCC PLUMBINGCODE OF AUSTRALIA VOLUME THREE THE DESIGN,CONSTRUCTION AND INSTALLATION OF ASTORMWATER DRAINAGE SYSTEM MUST BE INACCORDANCE WITH AS/NZS 3500.3
SITE PLAN NOTES
SOIL AND WATER MANAGEMENTPRIOR TO THE COMMENCEMENT OF THEDEVELOPMENT WORKS THE APPLICANT OR BUILDERMUST INSTALL ALL NECESSARY SILT FENCES AND CUT-OFF DRAINS TO PREVENT THE SOIL, GRAVEL ANDOTHER DEBRIS FROM ESCAPING THE SITE.ADDITIONAL WORKS MAY BE REQUIRED ON COMPLEXSITES.
NO MATERIAL OR DEBRIS IS TO BE TRANSPORTEDONTO THE ROAD RESERVE (INCLUDING THE NATURESTRIP, FOOTPATH AND ROAD PAVEMENT).ANY MATERIAL THAT IS DEPOSITED ONTO THE ROADRESERVE AS A RESULT OF THE DEVELOPMENT ACTIVITYIS TO BE REMOVED BY THE APPLICANT OR BUILDER.
THE SILT FENCING, CUT-OFF DRAINS AND OTHERWORKS TO MINIMISE EROSION ARE TO BE MAINTAINEDON THE SITE UNTILL SUCH TIME AS THE SITE HASREVEGETATED SUFFICIENTLY TO MITIGATE EROSIONAND SEDIMENT TRANSPORT.
North
SITE PLANSCALE 1:200
0mm 2000 4000 6000 8000 10000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
REV:3 of 7A02PRINT DATE:PROJECT NUMBER: ISSUE:SCALE: IF IN DOUBT ASK
0
APPROVAL
rev. Amendment Date
21084
Owner:A JONES
ABN 23 269 055 701
EX. ENTRY
EX. BED 01
EX. BED 02EX. BED 03
EX. DINING EX. LOUNGE
EX. KITCHEN
EX. BATHEX. LDRY
EX. F.P
EX. HEATEREX
. RAM
P
EX. SHED
DEMOLITON LEGEND
THE CONTRACTOR SHALL CARRY OUT THE REQUIREDDEMOLITON OF THE EXISTING BUILDING ELEMENTSNOMINATED ON THIS PLAN IN STRICT ACCORDANCEWITH THE DOCUMENTATION & AS2601 - THEDEMOLITION OF STRUCTURES.
DEMOLITION WORKS SHALL BE UNDERTAKEN IN ASAFE & ENVIRONMENTALLY ACCEPTABLE MANNER.CONTRACTOR SHALL MAKE ALL ALLOWANCES ASREQUIRED FOR DEMOLITION, REMOVALS &RELOCATIONS TO SUIT THE NEW WORKS.
ALL ITEMS TO BE DEMOLISHED SHOWN DOTTEDTYPICALLY. CONTACT DIAL BEFORE YOU DIGPRIOR TO ANY EXCAVATION WORKS. THEEXISTING RESIDENCE MAY CONTAIN ASBESTOS.ANY ASBESTOS SHALL BE REMOVED INACCORDANCE WITH WORK SAFE TASMANIACODE OF PRACTICE CP113 & STATUTORYREGULATIONS
WALLS, WINDOWS DOORS ANDJOINERY SHOWN DOTTED IS TOBE DEMOLISHED AND REMOVED
EXISTING WALLS RETAINED
Project North
DEMOLITION PLANSCALE 1:100
0mm 1000 2000 3000 4000 5000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
REV:4 of 7A03PRINT DATE:PROJECT NUMBER: ISSUE:SCALE: IF IN DOUBT ASK
0
APPROVAL
rev. Amendment Date
21084
Owner:A JONES
ABN 23 269 055 701
W.01
2,030x1,330
W.02700x1,330
W.032,090x1,330
W.04750x1,330
W.08
2,030x1,330
W.07
820x2,040
W.08
820x2,040
W.061,180x1,330
3,000
1A05
2A05
1A06
2A06
W.05
EX. F.P
NEW DECK
LIVING
NEW
VER
AND
AH
NEW ENS. W.I.RNEW MASTER
BED
BED 03NEWBATH
NEWCARPORT
DINING
LDRY
KITCHEN
BED 02
EX. SHED
STO
RAG
E
F
SKYLIGHT
SKYLIGHTN
EW B
EAM
OVE
R
NEW DOOR?820X2040
GRAVEL BASE
NEW PERMANENTLY FIXEDTIMBER SCREEN TO 1.7m ABOVEDECK FLOOR LEVEL WITH AUNIFORM TRANSPARENCY OFNO MORE THAN 25%.
Col.
Col.
Col.
Col.
FLOOR PLAN LEGEND
HARDWIRED SMOKE DETECTOR,REFER TO DRAWING A20 GENERALREQUIREMENTS
WET AREA
REFER TO HEALTH AND AMENITYINGENERAL REQUIREMENTS ONDRAWING A20 & WATERPROOFINGTABLE ON DRAWING A19
SD
POWDERCOATED ALUMINIUMFRAMED GLAZED WINDOWS REFERTO DOOR AND WINDOW SCHEDULE
PAINT GRADE HOLLOW CORE INTERIORSWING DOOR WITH ARCHITRAVES,JAMBS AND STOPS. PAINT FINISH
PAINT GRADE HOLLOW CORE (SOLIDIN WETAREAS) INTERIOR CAVITYSLIDING DOOR WITH ARCHITRAVESAND JAMBS. PAINT FINISH
INSULATED 90x35mm MGP.10 0R .12TIMBER STUD FRAMED WALLS, Pb LININGINTERNALLY, PAINT FINISH.PROVIDE VAPOUR PERMEABLE BUILDINGWRAP, LAP AND TAPE ALL JOINTS.REFER TO ELEVATIONS FOR EXTERNALCLADDING SELECTION.REFER TO INSULATION SCHEDULE FORTHERMAL REQUIREMENTS (R-VALUES)
W##
EXISTING WALLS RETAINED
BLOCKWORK MASONRY INACCORDANCE WITH ENGINEERINGDRAWINGS
Project North
FLOOR PLANSCALE 1:100
0mm 1000 2000 3000 4000 5000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
REV:5 of 7A04PRINT DATE:PROJECT NUMBER: ISSUE:SCALE: IF IN DOUBT ASK
0
APPROVAL
rev. Amendment Date
21084
Owner:A JONES
ABN 23 269 055 701
1A05
2A05
1A06
2A06
EX ROOFFALL
EX ROOFFALL
EX R
OO
FFA
LLEX
RO
OF
FALL
EX R
OO
FFA
LLEX
RO
OF
FALL
EX ROOFFALL
EX ROOFFALL
NEWSKILLION
ROOF
NEWSKILLION
ROOF
NEW
SKIL
LIO
NR
OO
F
D.P.
ROOF PLAN NOTES
AN AUSTRALIAN STANDARD ROOF SAFETY MESH ORAN APPROVED ROOF SAFETY HARNESS ORRESTRAINT SYSTEM SHALL BE USED DURINGINSTALLATION.
ROOF SHEETS MUST BE LAID WHEREVER POSSIBLEUSING COMPLETE LENGTHS FROM RIDGES TO EAVES.SHEET METAL ROOF, CAPPINGS, FLASHINGS ANDPENETRATIONS ARE TO COMPLY WITH PARTS 3.5.1.2& 3.5.1.3 AND OF THE BCA.
REFER TO ENGINEERS DETAILS FOR ROOF FRAMING.ENSURE THE ROOF SPACE IS VENTILATED AT THERIDGE CAPPING AND VIA VENTS LOCATED AT THEEAVES.
METAL SHEET ROOFING SHALL BE IN ACCORDANCEWITH PART 3.5.1. OF THE BCA. WHEREVER POSSIBLEHAVE THE SHEETS LAID SO THAT THE SIDE LAPS AREFACING AWAY FROM THE PREVAILING WEATHER.
REFER TO INSULATION SCHEDULE FOR INSULATIONREQUIREMENTS.
ROOF BATTENS MUST BE FIXED IN ACCORDANCEWITH AS 1684.4 SECTION 9 TABLES 9.2 TO 9.7.
GUTTERS AND DOWNPIPES SHALL BE INACCORDANCE WITH PART 3.5.2 OF THE BCA.ALL DWV PVC DOWNPIPES TO BE JOINTED WITHAPPROVED SOLVENT AND PRIMER. PAINT FINISH.
GUTTERS INSTALLED IN ACCORDANCE WTIHPART 3.5.3 OF THE BCA, NCC. 1 IN 500 FALL.
BOX GUTTERS WITH 1 IN 100 FALL AND INACCORDANCE WITH AS/NZS 3500.3
North
ROOF PLANSCALE 1:100
0mm 1000 2000 3000 4000 5000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
REV:6 of 7A05PRINT DATE:PROJECT NUMBER: ISSUE:SCALE: IF IN DOUBT ASK
0
APPROVAL
rev. Amendment Date
21084
Owner:A JONES
ABN 23 269 055 701
3,500
1,700
1.4m
NEWCARPORT
NEWDECK
SCREEN
NEWVERANDAHROOF
NEWCARPORT
ELEVATION NOTESWALL CLADDING SYSTEMS MUST BE INSTALLEDIN STRICT ACCORDANCE WITH MANUFACTURESDETAILS, INSTRUCTIONS & SPECIFICATIONS.
INSTALL THE WALL CLADDING SYSTEM COMPLETEWITH JOINTS, TRIMS, FLASHINGS , SEALS , FIXINGS& FINISHES IN STRICT ACCORDANCE WITHMANUFACTURES DETAILS TO ENSURE A WEATHER-PROOF AND WATERTIGHT INSTALLATION.
REFER TO GLAZING CALCULATOR FOR WINDOW &GLAZING DETAILS TYP.
1-
NORTHERN ELEVATIONSCALE 1:100
0mm 1000 2000 3000 4000 5000
2-
EASTERN ELEVATIONSCALE 1:100
0mm 1000 2000 3000 4000 5000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.
ALTERATIONS AND ADDITIONS52 MERIVALE ST, SOUTH LAUNCESTON TAS 7249
REV:7 of 7A06PRINT DATE:PROJECT NUMBER: ISSUE:SCALE: IF IN DOUBT ASK
0
APPROVAL
rev. Amendment Date
21084
Owner:A JONES
ABN 23 269 055 701
2,200
2,600
1,700
NEWCARPORT
NEWVERANDAHROOF
SCREEN
1,400
NEWDECK
SCREEN
ELEVATION NOTESWALL CLADDING SYSTEMS MUST BE INSTALLEDIN STRICT ACCORDANCE WITH MANUFACTURESDETAILS, INSTRUCTIONS & SPECIFICATIONS.
INSTALL THE WALL CLADDING SYSTEM COMPLETEWITH JOINTS, TRIMS, FLASHINGS , SEALS , FIXINGS& FINISHES IN STRICT ACCORDANCE WITHMANUFACTURES DETAILS TO ENSURE A WEATHER-PROOF AND WATERTIGHT INSTALLATION.
REFER TO GLAZING CALCULATOR FOR WINDOW &GLAZING DETAILS TYP.
1-
SOUTHERN ELEVATIONSCALE 1:100
0mm 1000 2000 3000 4000 5000
2-
WESTERN ELEVATIONSCALE 1:100
0mm 1000 2000 3000 4000 5000
PLANNING EXHIBITEDDOCUMENTS
Planning Administration
DA 0641/2021Ref. No:
Dateadvertised: 06/11/2021
This document is subject to copyright and is protected by law. In displaying thisdocument on its website the Council grants website users a non-exclusive licence toreproduce the document in their web browser for the sole purpose of viewing thecontent. The Council reserves all other rights. Documents displayed on the Council'swebsite are intended for public perusal only and should not be reproducedwithout the consent of the copyright owner.