2-8-534 HOOKUP CONNECTION GUIDE Using MEDIVATORS ® ADVANTAGE ® Automated Endoscope Reprocessors ADVANTAGE HOOKUP DIAGRAM Representative endoscope for illustrative purposes only. For exact port locations, refer to endoscope manufacturer’s instruction guide. Each ADVANTAGE Hookup is comprised of multiple ports and connector assemblies. Each port is labeled with a Port ID number (circled). This same number also identifies the corresponding Connector Assembly. READ ALL INSTRUCTIONS PRIOR TO CONNECTION Locate the endoscope port and follow the instructions for attaching the corresponding Endoscope Connector. All connectors must be attached. LOT XXXXXX ID: XXXX P/N: X-X-XXX Medivators Inc. 14605 28th Ave N. Minneapolis, MN 55447 USA Medivators BV Sourethweg 11 6422PC Heerlen The Netherlands ➂ ➁ ➀ ➄ ➅ ➆ ➇ ➃ S DESIGNATED HOOKUP FOR THE FOLLOWING PENTAX ® ENDOSCOPES*: EC-3470F EC-3470M EC-380Kp EC-3870FZK EC-3870M2 EC-3870SK EC-3880FK EC-3880SK2 EC-3881MK2 EC-3881MK EG-2970SK ES-3870 EC-3870CIFK EC-3470FK EC-3470MK EC-3870F EC-3870L EC-3870MK EC-3870SK2 EC-3880FK2 EC-3881FK EC-3881SK2 EC-3881MK2 EG-2980K ES-3870K EC-3870CILK EC-3470L EC-3480FK EC-3870F2 EC-3870LK EC-3870MK2 EC-3872L EC-3880LK EC-3881FK2 EC-3881FK EC-3881SK2 EG-3470 ES-3880K EC-3870CIMK EC-3470LK EC-3480LK EC-3870FK EC-3870LZK EC-3870MZK EC-3872KL EC-3880MK EC-3881LK EC-3881FK2 EG-2970 EG-3470K ES-3881K EC-3870CIMK2 EC-3470M EC-3480MK EC-3870FK2 EC-3870M EC-3870S2 EC-3872LZK EC-3880MK2 EC-3881MK EC-3881LK EG-2970K EG-3480K WC-3880K EG-3870CIK * This list of corresponding endoscope models is subject to change without notice. For a full list, please go to: www.medivators.com/hookuplookup © 2015 Medivators Inc. 50098-990-EN/A S Port ID Port Name Connector Assembly Description Order Number LEAK TEST Leak Test Connector Assembly H28534-1 JET/AUX Forward Water Jet Connector Assembly H28534-2 BIOPSY Biopsy Connector Assembly H28534-3 AIR Air/Water Connector Assembly H28534-46 ELEVATOR N/A N/A WATER Air/Water Connector Assembly H28534-46 SUCTION Suction Connector Assembly H28534-7 EXTRA N/A N/A S N/A Air/Water & Suction Port Separator 1-5-315 If a Connector Assembly needs replacement, locate the port number/name and use the corresponding order number found in the chart above. Connector Assemblies are specific to individual hookups. If you have any questions regarding this hookup, in the U.S., please contact Medivators Technical Support at 1-800-444-4729. Outside the U.S., please contact your Medivators Distributor. CONNECTOR ASSEMBLY IDENTIFICATION CHART Air/Water & Suction Port Separator Align the separator with piston ports and push to compress springs completely before sliding the frame forward to fully engage. Biopsy Connector Align the stainless steel fitting with biopsy port, push and turn clockwise to fully engage. Leak Test Connector Align the slot on connector with the pin on the scope. Push on and turn clockwise to engage. Suction Connector Align silicone tubing with suction barb and push tubing onto barb until fully engaged. Forward Water Jet Connector Align connector with forward water jet port, insert and screw clockwise until fully engaged. Air/Water Connector Align air/water fitting with endoscope port and insert. Screw knurled collar clockwise until fully engaged. (See also alternative FWJ location) Forward Water Jet Connector Align connector with forward water jet port, insert and screw clockwise until fully engaged. Alternate FWJ Connector (endoscope model depending) STEP 1: Locate alternate luer connector STEP 2: Separate male and female on the FWJ Connector Assembly luers by unscrewing. STEP 3: Remove check valve OE-C15 from OE-C12 and refit OE-C12 to scope. Attach OF-B113 to OE-C12 and female luer.