VF1000 Nl/min 147 26.4mm Width VF3000 Nl/min 981 26.4mm Width VF5000 Nl/min 2846 32mm Width 5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000 SY SYJ SX VK VZ VF VFR VP7 VQC SQ VQ VQ4 VQ5 VQD VZS VFS VS VS7 VQ7 SY SV Large flow capacity, Yet compact size. Low power consumption. 1.8WDC Exhausting equipment for pilot valve not required. Common exhaust for main valve and pilot valve is available. 1.7-1
36
Embed
5 Port Pilot Solenoid Valve Rubber Seal VF1000/3000/5000content.smcetech.com/pdf/VF_EU.pdf · ∗If exhaust for main valve and pilot valve is common, model number will be VF113 c,
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
VF1000Nl/min 14726.4mm Width
VF3000Nl/min 98126.4mm Width
VF5000Nl/min 284632mm Width
5 Port Pilot Solenoid ValveRubber Seal
VF1000/3000/5000SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
Large flow capacity,Yet compact size.
Low power consumption.1.8WDC
Exhausting equipment for pilot valve not required.Common exhaust for main valve and pilot valve is available.
1.7-1
Individual for pilot valve(Standard)
Common exhaunt for mainvalve and pilot valve(VF1000, VF3000)
Non-lockingpush style
Locking slotted style Locking knob style
Body portedVF1000VF3000VF5000
Base mountedVF3000VF5000
(Illustration: VF3000) (with sub-plate)
1.7-2
VF1000
VF1000 2 positionsingle
2 positionsingle
2 positiondouble
3 positionclosed centre
3 positionexhaust centre
3 positionpressure centre
2 positionsingle
2 positiondouble
3 positionclosed centre
3 positionexhaust centre
3 positionpressure centre
2 positiondouble
VF3000
VF5000
VF3000
VF5000
1 8
1 8 1 4 3 8
1 4 3 8 1 2
With indicator light and surge voltage suppressor(DIN connector)
AC /100V, 200V, 110V, 220V, 240V
DC /24V, 12V
Note)VF1000/3000
DIN connector(D) (Y)
style
B mount
A, B port
Valve
ExhaustVV5F1-30 VV5F3-30 VV5F3-60 VV5F5-20
Common, Individual
style
B mount
A, B port
Valve, base
Exhaust
Common
style
B mount
CYL port
Valve, base
Exhaust
Common, Individual
Exhaust
Common, Individual
CYL port
Valve
style
S mount
VF1000 VF3000 VF5000
VF1000/3000/5000
Many combinations available to fit your needs.
Manifold
VoltagesSurge Voltage Suppressor/Indicator Light
Electrical Entry
Piping
Pilot exhaust
Manual Override
Series/Port Size
CYL. 1CYL. 2A(CYL. 2)B(CYL. 1)
1.7-3
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instruction and common precautions.
Precautions
VF1000/3000/5000
Plug
Function
B port(CYL. 1port)
Aport(CYL. 2port)
N.C. N.O.
Sin
gle
Dou
ble
Sol
enoi
d
Lead wire colourConnection
Red Black+ –
Indicator light/Surge Voltage Suppressor Common Exhaust Port for the Pilot and Main Valve Interchangeability with V1000 and V3000Warning
Exhaust air from pilot valve will flow to mainvalve exhaust port. Exhaust air from mainvalve will not flow to pilot valve side due to acheck valve.Purpose•Not to exhaust mist from PE(Pilot Exhaust)port to protect the surrounding environment.•To lower the exhaust noise from PE portwhen switching valve.•To prevent silencer mounted to PE port fromgetting plugged in dusty environments.WarningsCommon exhaust valves are effective for usewith common exhaust manifolds, however anexhaust cleaner (Series AMC) should beinstalled when used in this manner. Makesure the exhaust port operates properly afterinstalling the exhaust cleaner.
Use as a 3 Port ValvePlugging one of the cylinder ports (A or B)enables use as a 3 port valve. It should notbe used in special applications such as anon-leakage valve. Make sure the exhaustport is open if used as a 3 port valve.
2) If the VF3000 is installed on sub—plateor base mounted manifold(B1, B2) in thesame position with V3000, air flow will bereversed. Follow either of these installa-tion procedures.A. Install the VF3000 on the sub-plate or
manifold base in the opposite direction.B. Install the VF3000 in the same position as
the V3000 but reverse the piping of theCYL port.
Electrical ConnectionDIN connection are free from +/– direction.Connect No. 1 and 2 terminals to the powersource.
Grommet connection
DIN connector,
•Applicable Cable O.D.D type: ø4.5 to ø7mmT type: ø6 to ø8mmE type: ø2.3 to ø2.8mm
Vol
tage
Cricuit Model DIN connecter (D)(Y)
Z
Z
EZ, TZ, DZ, LZ, MZ(100V AC or more)
EZ, TZ, DZ, LZ, MZ(24V AC or less)
EZ, TZ, DZ, LZ, MZ(100V DC or more)
EZ, TZ, DZ, LZ, MZ(24V AC or less)
AC
DC
Indi
cato
r lig
ht a
nd s
urge
vol
tage
supp
ress
orIn
dica
tor l
ight
and
sur
ge v
olta
gesu
ppre
ssor
Note) Grommet: Surge suppressor only
With DIN connector
VF3000 V3000
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SVV1000 and V3000 are respectively inter-changeable with VF1000 and VF3000.Mounting and style are the same and theycan be replaced by VF1000/3000. However,care must be taken because the main valveswitching differs from the VF3000 to theV3000.1) In case cylinder port is body ported.Port position of CYL1 and CYL2 are oppo-sites. Make sure of the port symbol and pipeso that back actuation does not occur.
Dust proofIndividual exhaust, Common exhaust for main valve and pilot valve
Note 1)
Note 2)
Based on dynamic performance test JIS B8375-1981(Coil temperrature 20°C, at rated voltage,without surge voltage suppressor.)Impact resistance:
Vibration resistance:
No malfunction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states. No malfunction occurred in a one-sweep test between 8.3 and 2000Hz.Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature. (Valve in the initial s tage.)
Electrical entry
Voltages (V)
Apparent power (1)
Allowable voltage
Indicator light and Surge voltage suppressor
DC
AC
DCACDC
AC50/60Hz
In-rushHolding
Power comsumption (1)
DIN terminal
100, 200, 110, 220, 24024, 12
–15 to +10% of rated voltage5.6VA(50Hz), 5.0VA(60Hz)3.4VA(50Hz), 2.3VA(60Hz)
ZNR(Varistor), Neon light (LED 100V or less)1.8W, 2W(With LED)
ZNR(Varistor), LED(Neon lamp 100V or more)
∗ Option Note 1) At rated voltage.
Description
Bracket
SilencerThrottle valve
Part No. NotesDXT144-8-1A for VF1220DXT144-8-3A for VF1120
AN120-M5 M5DXT154-34-1A With element
Piping Model
Body ported VF1120-��-01VF1220-��-01
Position/Solenoid
2/Single2/Double
(1)Port size
1 81 8
Effective areamm2(Nl/min)
2.7(147)2.7(147)
Weight(kg)
0.160.25
Note 1) Exhaust (EA, EB) port is M5 X 0.8.
Model∗
VF1�30-��-01
ManifoldStyle
B mount3031
CommonIndividual
ValveExhaust A, B port
Valve
∗ If exhaust for main valve and pilot valve is common, model number will be VF113 c, VF123c.
Specifications
Option
Model
Model for Manifold
VF1220(DIN connector)
JIS Symbol
Single VF1120
VF1120(DIN connector withbracket)
Double VF1220
1 8
1.7-5
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
No. Description
ResinAluminium die-cast
MaterialAluminium die-cast
Resin
BlackBlack
NotesMetallic paint
Adapter plateBody
End coverPilot body
ResinPilot coverResinPiston
Spool
q
w
e
r
t
y
u
No. Description Material Part No.SF4-���-50∗Pilot valve assembly
∗ Please refer to "How to Order Pilot Valve Assembly" right above
i
VF1000
Rc (PT)G (PF)NPT
NPTF
F-
NT
Thread
Body ported VF1 1 2 0 1 D 01 Q
For manifold VF1 1 3 0 1 D 01
Actuation1 Single solenoid2 Double solenoid
Port size(P, A, B)
EA, EBport:M5
01
Indicator light/surge voltage suppressor
– None
Z
Electrical entry
DINconnecter
DINconnecter
(DIN43650B)
DDOY
YO
Body option0 Standard
3∗Common exhaust for main valve and pilot valve
Voltage12
5
34
679
200V AC, 50/60Hz110 to 120V AC, 50/60Hz220V AC, 50/60Hz
: With indicator light and surge voltage suppressor
L: Dimensions(mm)
: With indicator light and surge voltage suppressor
nLL1
L2
274.564.5
310292
4129.5119.5
5157147
6184.5174.5
7212202
8239.5229.5
9267257
10294.5284.5
11322312
12349.5339.5
13377367
14404.5394.5
15432422
16459.5449.5
17487477
18514.5504.5
19542532
20569.5559.5
n: StationL: Dimensions(mm)
Individual exhaust/VV5F1-31-��3-�
Note: This valve series is now only available with DIN connector.
Note: This valve series is now only available with DIN connector.
1.7-11
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
5 Port PilotRubber Seal
Series VF3000Specifications
Options
FluidOperating pressure range
Ambient and fluid temperatture
Response time(1)
Max. operating cycle
Lubrication
Mounting positionImpact/Vibration resistance(2)
EnclosurePilot exhaust
2 posotion single/3 position2 position double
2 position single/double3 position
2 position single/double3 position
Air0.15 to 0.9MPa0.1 to 0.9MPa
Max. 50°C20ms or less(At 0.5MPa)40ms or less(At 0.5MPa)
10Hz3Hz
Not requiredManual override Non-locking push, Locking slotted, Locking knob
Free300/50m/s2
Dust proofIndividual exhaust, Common exhaust for main valve and pilot valve
Impact resistance:
Vibration resistamce:
No malfuction resulted from the impact test using a drop impact tester.The test was performed on the axis and right angle directions of the main valve and armature, or both energized and de-energized states. No malfunction occurred in a one-sweep test between 8.3 and 2000Hz.Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature.(Valve in the initial stage.)
Single VF3130 Closed Centre VF3330 Exhaust Centre VF3430 Pressure Centre VF3530
Double VF3230
Body Ported
Base mounted (with sub-plate)
Compact and light weight:26.4mm widthLarge flow capacity:Nl/min 981, 1/4Low power consumption:1.8W(DC)
1.7-12
Model for Manifold
Model
VF3000
Piping
Body ported
Base mounted(with sub-plate)
Model (1)
VF3122-��- -F-Q0102
VF3130-��- -�-Q0102
VF3230-��- -�-Q 0102
VF3330-��- -�-Q 0102
VF3430-��- -�-Q 0102
VF3530-��- -�-Q 0102
VF3140-��- -�-Q 0203
VF3240-��- -�-Q 0203
VF3340-��- -�-Q 0203
VF3440-��- -�-Q 0203
VF3540-��- -�-Q 0203
Position/Solenoid
2/Single2/Single2/Double
3/Closed centre3/Exhaust centre
3/Pressure centre
2/Single2/Double
3/Closed centre3/Exhaust centre
3/Pressure centre
Port (2)
size
1 8
1 4
1 4
3 8
Effective area(Nl/min) mm2
1 8 1 4 3 8
– 0.240.210.290.440.44
0.44
0.380.470.610.61
0.61
––––
–
––––
–
Weight (kg)
(1) If exhaust for main valve and pilot valve is common, model number will be VF3�33, VF3�43 (2) In case of body ported, exhaust (EXH) port (R1, R2) is only . (3) Weight is for grommet type.(4) In centre position the flow "P→A, B" is shown.
Note: This valve series is now only available with DIN connector.
1.7-15
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
VF3000
: With indicator light and surge voltage suppressor
Body Ported: 2 Position Single SolenoidGrommet/VF3130-�G Grommet terminal/VF3130-�E
Conduit terminal/VF3130-�T DIN connector/VF3130-�D/Y
: With indicator light and surge voltage suppressor : With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
1.7-16
VF3000
: With indicator light and surge voltage suppressor
Body Ported: 2 Position Double Solenoid, 3 Position Closed Centre/Exhaust Centre/Pressure CentreGrommet/VF3�30-�G Grommet terminal/VF3�30-�E
Conduit terminal/VF3�30-�T DIN connector/VF3�30-�D/Y
: With indicator light and surge voltage suppressor: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
Note: This valve series is now only available with DIN connector.
1.7-17
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
VF3000
: With indicator light and surge voltage suppressor
Base Mounted (With sub-plate): 2 Position Single SolenoidGrommet/VF3140-�G Grommet terminal/VF3140-�E
Conduit terminal/VF3140-�T DIN connector/VF3140-�D/Y
: With indicator light and surge voltage suppressor: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
1.7-18
VF3000
: With indicator light and surge voltage suppressor
Base Mounted (With sub-plate): 2 Position Double Solenoid, 3 Position Closed Centre/Exhaust Centre/Pressure CentreGrommet/VF3�40-�G Grommet terminal/VF3�40-�E
Conduit terminal/VF3�40-�T DIN connector/VF3�40-�D
: With indicator light and surge voltage suppressor: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
VV5F3-60
1.7-19
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
Series VF3000Manifold
Manifold Specifications
Options
How to Order Manifold BasePlease indicate the appropriate valves and/or blank plate assembly and manifold base separately.(Example) VV5F3-40-052-02 1pc. (Manifold base)
B mount(Single Base type) S mountCommon Individual
20 10Common Individual
∗ In case of more than 8 stations for B mount or more than 4 stations for S mount, supply air from both sides of P(SUP.) port and exhaust from both sides of R(EXH.) port.
Model
VV5F3-30
VV5F3-40
(1)Exhaust
Common
Common
Piping/Port locationP(SUP) R(EXH) A, B(CYL) P(SUP) R(EXH) A, B(CYL)
SideBaseSideBase
SideBaseSideBase
TopValveBottomBase
Port size
1 4
1 4
VV5F3-50 IndividualSideBase
TopValve
BottomBase
1 4
VV5F3-60 CommonSide
SideplateTop
SideplateTop
Valve1 4
VV5F3-61 CommonSide
SideplateSide
SideplateSide
Valve1 4
VV5F3-70 IndividualSide
SideplateBottomValve
TopValve
1 4
VV5F3-71 IndividualSide
SideplateSide
ValveSide
Valve1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 4
1 8
1 4
1 4
1 4
1 8
1 4
1 8
1 4
1 8
1 4
1 8
Applicablevalve
VF3�30VF3�33
Note 1) Supply (P port) is common.Note 2) Common exhaust for main valve and pilot valve is possible only in the valves of common exhaust.
VF3�40VF3�43
VF3�50
VF3�60VF3�63
VF3160VF3163
(Only single solenoid)
VF3�70
VF3170(Only single solenoid)
Manifold
B mount
S mount
DescriptionSpacer ass'y for individual exhaust∗
Blank plate ass'y
Part No. Applicable manifoldDXT155-17-1A VV5F3-30, 40DXT031-38-1A VV5F3-30, 40, 50
∗ Used to exhaust air individually from certain valves mounted on common exhaust manifolds "type 30"and "type 40".
B mount (Integrated style)
Top piping/Common exhaust 30 Type
Bottom piping/Common exhaust40 Type
2 stations
20 stations
02
20
Stations
VV5F3 0530 1
VV5F3 0540 2 02
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
Code
EN
areasJapan,AsiaAustralia
EuropeNorth America
Ordering source area code
-
... ...
2 stations
20 stations
02
20
Stations
Code
EN
areasJapan,AsiaAustralia
EuropeNorth America
Ordering source area code
-
... ...
Thread
Rc (PT)G (PF)NPT
NPTF
F-
NT
Thread
Applicable solenoid valves
VF3�30-����-
VF3�33-����-
Applicable blank plate ass´y DXT031-38-1A
Applicable spacer ass´y for individual exhaust DXT155-17-1A
–15 to + 10% of rated voltage5.6VA(50Hz), 5.0VA(60Hz)3.4VA(50Hz), 2.3VA(60Hz)
ZNR(Varistor), Neon lamp(LED100V or less)1.8W, 2W(With LED)
ZNR(Varistor), LED(Neon lamp100V or more )
Note 1) At rated voltage
Body type
Body ported
Base mounted(With sub-plate)
Model (1)
VF5120-��-0203
VF5220-��-0203
VF5320-��-0203
VF5420-��-0203
VF5520-��-0203
VF5144-��-020304
VF5244-��-020304
VF5344-��-020304
VF5444-��-020304
VF5544-��-020304
Position/Solenoid
2/Single
2/Single
2/Double
2/Double
3/Closed centre
3/Closed centre
3/Exhaust centre
3/Exhaust centre
3/Pressure centre
3/Pressure centre
Port size
1 4
1 4
3 8
1 4
3 8
1 2
3 8 1 2 1 4, 1 2 3 8
Effective area (Nl/min)mm2 Weight(2)
34.2(1864) 45(2453) – 0.38 –0.45 –0.56 –0.56 –
0.56 –
–––
–
34.2(1864)
34.2(1864) 45(2453) 52(2846) 0.57 0.62
34.2(1864) 45(2453) 52(2846) 0.65 0.69
33(1766) 34(1864) 38(2061) 0.74 0.79
36(1963) 39(2061) 44(2355) 0.74 0.79
0.74 0.79
45(2453)30.6(1668) 36(1963)32.4(1766) 41.4(2257)
36(1963)14.8(785)(3)
33.3(1815)10.8(588)(3)
36(1963)15.3(834)(3)
39.6(2159)15.3(834)(3)
36(1963)15.3(834)(3)
Note 1) Body ported valves can be mounted on manifold directry. (Manifold: B mount/Common EXH)Note 2) Weight is for Grommet style.Note 3) In centre position the flow "P→ A, B" is shown.
Compact and light weight:32mm widthLarge flow capacity: Nl/min 2846,
Low power consumption: 1.8W(DC)
1 2
Body Ported
Base mounted (with sub-plate)
JIS Symbol
SingleVF5120
DoubleVF5220
Closed CentreVF5320
Exhaust CentreVF5420
Pressure CentreVF5520
FluidOperating pressure rangeAmbient and fluid temperature
Response time (1)
Max.operating cycle
Lubrication
Mounting positionImpact/Vibration resistance
(2)
Enclosure
2 position single, 3 position2 position double
2 position single/double3 position
2 position single/double3 position
Air0.15 to 0.9MPa0.1 to 0.9MPa
Max. 50°C30ms or less(A to 0.5MPa)50ms or less(A to 0.5MPa)
Based on dynamic performance test JIS8375-1981(Coil temperature 20°C, at rated voltage, without surge voltage suppressor.)Impact resistance:
Viblation resistance:
No malfuction resulted from the impact test using a drop impact tester. The test was performed on the axis and right angle directions of the main valve and armature, for both energized and de-energized states.(Value in the initial stage.) No malfunction occurred in a one-sweep test between 8.3and 2000Hz. Test was performed at both energized and de-energized states to the
1.7-26
VF5000
Body ported VF5 1 1 G 03
VF5 1 1 G 03
20
44Base mounted
Port size
– Withoutsub-plate
02 1 4
03 3 8
04
Manual override
–Non-lockingpush style
B Locking slotted style
C Locking knob style1 2
Indicator light/surge voltage suppressor– NoneZ∗ With indicator light/surge voltage suppressor
Body Ported: 2 Position Single SolenoidGrommet/VF5120-�G Grommet terminal/VF5120-�E
Conduit terminal/VF5120-�T DIN connector/VF5120-�D/Y
: With indicator light and surge voltage suppressor
: With indicator light and surge voltage suppressor: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
1.7-29
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
VF5000
Body Ported: 2 Position Double Solenoid, 3 Position Closed Centre/Exhaust Centre/Pressure CentreGrommet/VF5�20-�G Grommet terminal/VF5�20-�E
Conduit terminal/VF5�20-�T DIN connector/VF5�20-�D/Y
: With indicator light and surge voltage suppressor
: With indicator light and surge voltage suppressor: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
1.7-30
VF5000
Base Mounted: 2 Position Single Solenoid
Grommet/VF5144-�G Grommet terminal/VF5144-�E
Conduit terminal/VF5144-�T DIN connector/VF5144-�D
( ): VF5144-�E-04: With indicator light and surge voltage suppressor( ): VF5144-�G-04
( ): VF5144-�D-04: With indicator light and surge voltage suppressor
( ): VF5144-�T-04: With indicator light and surge voltage suppressor
Note: This valve series is now only available with DIN connector.
1.7-31
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
VF5000
Base Mounted: 2 Position Double Solenoid, 3 Position Closed Centre/Exhaust Centre/Pressure CentreGrommet/VF5�44-�G Grommet terminal/VF5�44-�E
Conduit terminal/VF5�44-�T DIN connector/VF5�44-�D
( ): VF5�44-�G-04< >: 3 position
( ): VF5�44-�E-04: With indicator light and surge voltage suppressor
< >: 3 position
( ): VF5�44-�D-04: With indicator light and surge voltage suppressor
< >: 3 position
( ): VF5�44-�T-04: With indicator light and surge voltage suppressor
< >: 3 position
Note: This valve series is now only available with DIN connector.
1.7-32
ManifoldExhaustMaximum stations
B mount(Single base)
Common10 (15 for 21 type w/side block)∗
∗ In case of more than 5 station for type 20 and 40 or more than 8 station for type 21, supply air from both sides of supply (P) port and exhaust air from both sides of exhaust (R) port.
Series VF5000
Manifold
Manifold Specifications
Options
How to Order Manifold Base
Please indicate the appropriate valves and/or blank plate assembly and manifold base separately.(Example) VV5F5-20-051 1pc. (Manifold base)
∗ Its effective area is 80% of that with sub-plateNote 1) P(SUP) port is all common.Note 2) Model number for valve unit is that for application manifold.
VF5�44
ApplicableValve
Description
Spacer ass'y for individual exhaust (1)
Blank plate ass'y
Part No. Applicable manifoldDXT156-20-1A VV5F5-20, 21
DXT156-19-1A VV5F5-20, 21DXT156-20-3A VV5F5-40
DXT156-19-2A VV5F5-40
Note 1) Spacer is used when it is necessary to exhaust from certain valves individually.
VV5F5-21
VV5F5-20
1.7-33
SY
SYJ
SX
VK
VZ
VF
VFR
VP7
VQC
SQ
VQ
VQ4
VQ5
VQD
VZS
VFS
VS
VS7
VQ7
SY
SV
VF5000
B mount (Integrated style)
Top piping/Common exhaust 20 Type
Top piping/Common exhaust21 Type
2 stations
10 stations
02
10
Stations
VV5F5 0520 1
Bottom piping/Common exhaust 40 Type
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
Code
EN
areasJapan,AsiaAustralia
EuropeNorth America
Ordering source area code
-
... ...Thread
2 stations
15 stations
02
15
Stations
VV5F5 0521 1
Rc (PT)G (PF)NPT
NPTF
00F-
00N00T
Code
EN
areasJapan,AsiaAustralia
EuropeNorth America
Ordering source area code
-
... ...
Thread
VV5F5 0540 2 02
2 stations
10 stations
02
10
Stations
Code
EN
areasJapan,AsiaAustralia
EuropeNorth America
Ordering source area code
-
... ...
Rc (PT)G (PF)NPT
NPTF
F-
NT
Thread
Applicable solenoid valves VF5 20- -
Applicable blank plate ass´y DXT156-20-1A