SOUND VETERINARY EQUIPMENT • P: 1300 881 681 • F: 1300 881 682 3 Issue: SC05/14 CRITICAL CARE CONSUMABLES 2014 SurgiVet Consumables Catalogue
SOUND VETERINARY EQUIPMENT • P: 1300 881 681 • F: 1300 881 682 3
Issue: SC05/14
CRIT
ICA
L CA
RE C
ON
SUM
ABL
ES
2014 SurgiVet Consumables Catalogue
SURGIVET™ CRITICAL CARE CONSUMABLES2
TABLE OF CONTENTS
Airway Management 3
Gastroenterology 8
Fluid Administration & Therapy 12
Needles 14
Reproduction 15
Urology 16
Central Venous Catheters 20
Wound Management 22
Consumable Product Accessories 28
Product Index 32
Products marked with this symbol are reusable and autoclavable
Large Animal Cuffed Endotracheal Tubes, Page 5
ClearView Oral/Nasal Oxygen/Feeding Tubes, Page 9
Subcutaneous Catheter Set, Page 13
Slippery Sam Tomcat Catheters, Page 16
Economy ClearView & Premium Foley Catheters, Page 18-19
Thoracic Drainage Catheters, Page 23
SURGIVET™ CRITICAL CARE CONSUMABLES 3
Non-Cuffed Endotracheal Tubes (Silicone)
Non-cuffed endotracheal tubes are typically used for birds, reptiles, amphibians, marsupials, neonates and very small animals.Features:• Non-sterile• Radiopaque• Parallel wall design• Silicone• Reusable and autoclavable• Wire guide stylet supplied
Code Tube I.D. (mm) Length (cm)AT10 1.0 12
AT15 1.5 12
Non-Cuffed Endotracheal Tubes (Silicone)
Non-cuffed endotracheal tubes are typically used for birds, reptiles, amphibians, marsupials, neonates and very small animals.
Features:• Non-sterile• Lowerprofiledistalportionofthetubeassistsplacement.• Larger proximal tube portion forms a seal against the vocal cords to reduce
anaesthesia gas loss.• Stepped wall design (Cole-Style Tube)• Reusable and autoclavable• Radiopaque
Code Tube I.D. (mm) Tube O.D. at Shoulder (mm)
French Size Length (cm)
AT20 2.0 5.0 9 13
AT25 2.5 6.3 12 13
AT30 3.0 8.0 13.6 15
AT35 3.5 8.6 16 15
AT40 4.0 9.6 18.3 15
AT50 5.0 12.6 23.6 18
AIRWAY MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES4
Non-Cuffed Wire Reinforced Endotracheal Tubes (Silicone)
Features:• Non-sterile and transparent• Radiopaque marker in distal tip• Reusable and autoclavable• Recommended to be used with malleable stylets.
Code Tube I.D. (mm) Tube O.D. (mm) French Size Length (cm)ATR25 2.5 4.0 12 14
ATR30 3.0 4.7 14 16
ATR35 3.5 5.3 16 18
ATR40 4.0 6.0 18 20
ATR45 4.5 6.7 20 22
ATR50 5.0 7.3 22 24
Cuffed Wire Reinforced Endotracheal Tubes (Silicone)
Features:• Non-sterile• Radiopaque marker in distal tip• Reusable and autoclavable• 15mm connector
Code Tube I.D. (mm) Tube O.D. (mm) French Size Length (cm)V35W30 3.0 4.7 14 16
V35W40 4.0 6.0 18 20
V35W50 5.0 7.3 22 24
JET-100 6.0 8.7 26 28
JET-110 7.0 10.0 30 30
JET-120 8.0 11.3 34 32
JET-130 9.0 12.7 38 34
JET-140 10.0 14.0 42 36
AIRWAY MANAGEMENT
Endotracheal Tube Stylet with Stopper
Features:• Stainless steel endotracheal tube stylet with silicone stopper• Non-sterile• Autoclavable• Malleable
Code Fits (mm)VSTYLSM 2.5 - 5.5
VSTYLLG 5.5 - 9.5
SURGIVET™ CRITICAL CARE CONSUMABLES 5
Cuffed Endotracheal Tubes (Silicone)
Thetubeispositionedwithinthetracheabyoralintubation.Thecuffisinflatedtopreventthe leakage of anaesthetic gas around the tube. The smaller sizes will often require a malleable stylet (VSTYLSM or VSTYLLG) to aid in introduction.
Features:• Non-sterile and transparent• Reusable and autoclavable• Radiopaque• Tubesupto12mmhavea15mmairwayadaptorfitting.• A funnel type silicone adaptor is supplied with 14mm and 16mm tubes as well as a
15mm adaptor.• Tubes 18mm upwards are only supplied with the funnel adaptor.• Repaircuffsandinflationlinesavailable.
Code Tube I.D. (mm)
Tube O.D. (mm)
French Size
Length (cm)
Balloon Length (cm)
ET2 2 3.7 10 16 2
ET3 3 4.7 14 16 2
ET4 4 6.0 18 18 2
ET5 5 7.3 22 20 3
ET6 6 8.7 26 28 4
ET7 7 10.0 30 30 5
ET8 8 11.0 33 32 5
ET9 9 12.4 37 34 5
ET10 10 14.3 43 36 5
ET11 11 15.7 47 40 5
ET12 12 17.0 51 40 5
ET14 14 19.0 57 57 6
ET16 16 22.0 66 70 7.5
ET18 18 24.0 72 75 7.5
ET20 20 26.5 79 90 9
ET22 22 30.0 90 90 9
ET24 24 32.0 96 90 9
ET26 26 35.0 105 100 10
ET30 30 42.0 126 100 10
AIRWAY MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES6
Endotracheal Tube Connectors
Features:• Manufactured to exact tolerances to ensure a safe, secure and leak-resistant
connection.• Tubeconnectorsaredesignedtofitthe54mm(2”)O.D.largeanimalypiece
with Bivona insert.
Code Tube I.D. (mm)
Code Tube I.D. (mm)
Code Tube I.D. (mm)
32121B3 14 32121B5 20 32121B8 26
32121B4 16 32121B6 22 32121B9 30
32121B12 18 32121B7 24 32121B10 35
Large Animal Endotracheal Tube Funnel Adaptor (Silicone)
Features:• Replacement Large Animal Endotracheal Tube Funnel Adaptor
Code Tubes (mm)32364B1 14, 16, 18, 20, 22, 24, 26, 30
Endotracheal Tube Replacement Accessories (Silicone)
Features:• Autoclavable - Non-sterile
Code Inflation Lines Repair Cuff Airway Adaptor AdhesiveET2 RILS RK2 ETCO2 ADH2
ET3 RILS RK3 ETCO3 ADH2
ET4 RILS RK4 ETCO4 ADH2
ET5 RILS RK5 ETCO5 ADH2
ET6 RILS RK6 ETCO6 ADH2
ET7 RILS RK7 ETCO7 ADH2
ET8 RILS RK8 ETCO8 ADH2
ET9 RILS RK9 ETCO9 ADH2
ET10 RILS RK10 ETC10 ADH2
ET11 RILS RK11 ETC11 ADH2
ET12 RILS RK12 ETC12 ADH2
ET14 RILS RK14 32121B3 ADH2
ET16 RILL RK16 32121B4 ADH2
ET18 RILL RK18 32121B12 ADH2
ET20 RILL RK20 32121B5 ADH2
ET22 RILL RK22 32121B6 ADH2
ET24 RILL RK24 32121B7 ADH2
ET26 RILL RK26 32121B8 ADH2
ET30 RILL RK30 32121B9 ADH2
AIRWAY MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES 7
Foal Nasal/Porcine Endotracheal Tubes (Silicone)
Features:• Non-sterile• Reusable and autoclavable• Tubesupto12mmhavea15mmairwayadaptorfitting.• A silicone funnel is supplied on the 14mm tube size.• Repairballooncuffsandinflationlinesareavailable.• Radiopaque
Code Tube I.D. (mm) Tube O.D. (mm) Length (cm)FN7 7 10 55
FN8 8 11 55
FN9 9 12.3 55
FN10 10 14.3 55
FN11 11 15.7 55
FN12 12 17 55
FN14 14 19 55
Equine Post Anaesthetic Nasal Tubes (Silicone)
Features:• Non-sterile• Reusable and autoclavable• Aproximalsiliconefunnelfittingtoavoidtubemigration.• Cuffed• Radiopaque
Code Tube I.D. (mm) Tube O.D. (mm) Length (cm)ENAT14 14 19 40
Tracheostomy Tubes (Silicone)
Features:• Sterile• Reusable and autoclavable• Pre-curvedsiliconeforacomfortableanatomicalfit.• For long term or permanent tracheostomy• Cuffed• Radiopaque
Code Tube I.D. (mm) Length (cm)V60050 5 6
V60060 6 7
V60070 7 8
V60080 8 8.8
V60090 9 9.8
AIRWAY MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES8
OESOPHAGEAL TUBES
Oesophagostomy Tubes are catheters that are introduced into the oesophagus via a percutaneous puncture in the side of the neck for enteral feeding. Nasogastric tubes are commonly used for enteral feeding, but the size of the animal’s nostrils limits the size of the tube that can be used. Commercial liquid diets can go down the smaller diameter tubes, but larger tubes such as the oesophagostomy tubes allow the use of less expensive solutions which are thicker in form.
Feline Oesophagostomy Tubes
Features:• Sterile• Reusable and autoclavable• A surgically placed closed-end single lumen silicone catheter with distal
side holes for the administration of enteral feeding solutions.• Removableproximalfittingacceptsstandardluerlocksyringes.• Radiopaque
Code French Size Length (cm) Proximal FittingFET1423 14 23 Removable
FET1938 19 38 Removable
Each Catheter Includes:1 PFLLA Female Luer Lock Tapered Adaptor1 LLP100 Luer Lock Plug
Oesophagostomy Tube Sets
Features:• An open-end silicone catheter with multiple side holes used for the administration
of enteral feeding solutions.• Catheter introduced after percutaneous puncture of the upper oesophagus with the
supplied Peel-off sheath.• Accurate positioning of the Peel-off sheath needle is aided with use of the
introduction tube.• Sterile• High quality, non-irritating silicone.• Suppliedwithcatheterandfivesheaths.
Code DescriptionOTCS12 12FR Silicone Catheter 60cm long with 8ga, 7cm long Peel-off Sheath Needles (5)
OTCS14 14FR Silicone Catheter 60cm long with 7ga, 7cm long Peel-off Sheath Needles (5)
Code Replacement PartsOTC1260 Silicone Oesophagostomy Catheter, 12FR, 60cm long
OTC1460 Silicone Oesophagostomy Catheter, 14FR, 60cm long
NPOS875 5 Peel-off Sheath Needles 8ga 7cm, 1 needle
NPOS775 5 Peel-off Sheath Needles 7ga 7cm, 1 needle
GASTROENTEROLOGY
SURGIVET™ CRITICAL CARE CONSUMABLES 9
ORAL/NASAL OXYGEN FEEDING TUBES
These tubes can be introduced nasally or orally to allow administration of enteral feeding solutions into the stomach or the proximal area of the lower oesophagus. These tubes can also be utilised as nasal lines to provide supplemental oxygen by placing the tip into the nasopharyngeal space.
Economy Clearview Oral/Nasal Oxygen/Feeding Tubes
Features:• Non-sterile• Reusable and autoclavable• A closed-end, single lumen silicone catheter used for the administration of feeding
solutions.• Recommended to be used with PTFE Coated Wire Guides• Integralcaponlightweightproximalfitting(noneedforadaptorsorluerlockplugs)• Clearview allows visualisation of feeding solutions or any occlusions.• Radiopaque• Atraumatic
Code French Size
Length (cm)
Code French Size
Length (cm)
CFT3520 3.5 20 CFT855 8 55
CFT520 5 20 CFT875 8 75
CFT535 5 35 CFT8120 8 120
CFT635 6 35 CFT1040 10 40
CFT655 6 55 CFT1055 10 55
CFT830 8 30 CFT10150 10 150
GASTROENTEROLOGY
ClearView PTFE Coated Wire Guide
Features:• Recommended to be used with Economy Clearview Oral/Nasal Oxygen/Feeding
Tubes and Clearview Foley Catheters. • Sterile• Autoclavable
Code Outer Diameter (in)
Length (cm)
For use with CFC Catheters &
Feeding TubesTCGW2170 0.021” 70 5 Fr & 6 Fr
TCGW3570 0.035” 70 8 Fr
TCGW3870 0.038” 70 10 Fr
TCGW38180 0.038” 180 10 Fr
SURGIVET™ CRITICAL CARE CONSUMABLES10
STOMACH TUBES
Gastrostomy Tube Introduction Set
Features:• Reusable introduction set that enables the non-endoscopic placement of gastrostomy
tubes into the stomach.• Designed to accept either 16 or 20 Fr Peg Feeding Tubes.• Autoclavable, supplied sterile.• GTIS1000 is recommended for use with animals up to 10kg.• GTIS2000 is recommended for use with animals over 10kg.• Contact us for details on use.
GTIS1000 Includes:GTI070TW Stainless Steel Threaded Wire 1mm O.D. 70cm
GTI545IT Introduction Tube 5mm O.D. 45cm
GTI75FA Catheter Fixation Adaptor, Tapered
GTIN1050 Percutaneous Needle 10ga 7cm
GTIS2000 Includes:GTI070TW Stainless Steel Threaded Wire 1mm O.D. 70cm
GTI9585IT Introduction Tube 9.5mm O.D. 85cm
GTI75FA Catheter Fixation Adaptor, Tapered
GTIN1050 Percutaneous Needle 10ga 7cm
Peg Feeding Tubes
Features:• A mushroom/Pezzar style silicone catheter for the percutaneous administration of
feeding solutions into the stomach.
• Can be endoscopically guided or used with a non-endoscopic introduction technique.• The mushroom shaped distal tip assists in retention of the catheter in the stomach.• Catheter markings at 2cm and 4cm from the base of the mushroom tip assist in
correct catheter placement.• The Peg Tube is more secure and can be left in place for a much longer length of
time than any other alternatives.• Silicone• Radiopaque• Reusable and autoclavable• Sterile
Code French Size Length (cm) Mushroom Tip Diameter (mm)
PT16 16 39 15
PT16XL 16 39 20
PT20 20 39 20
PT20XL 20 39 25
PT24XL 24 39 30
GASTROENTEROLOGY
SURGIVET™ CRITICAL CARE CONSUMABLES 11
Features:• A closed ended single lumen silicone catheter with distal side holes used for the
administration of enteral feeding solutions. • Proximalfittingacceptsataperedsyringeadaptor.• Reusable and autoclavable• Radiopaque.• Non-sterile
Feline Orogastric Feeding Tube
Code French Size Length (cm)FOT1843 18 43
Fixation Disc (Sterile)
Features:• Siliconefixationdisc• Used to stabilise percutaneous drainage catheters.• Sterile
Code DescriptionFD100 Silicone Fixation Disc
GASTROENTEROLOGY
SURGIVET™ CRITICAL CARE CONSUMABLES12
Connecting Tubes
Features:• Connecting tubes can be used in a variety of ways such as connecting urinary
catheters to collection bags, drainage tubes to suction, nasal lines to oxygen and infusion of liquids into venous circulation.
• Sterile
Code DescriptionCT95250 Flexible Spiral Connecting tube Set 9.5Fr, uncoiled length 250cm. Rotating
adaptor is designed to prevent tangling of lines during infusion therapy.
CT9530 Connecting tube with male Luer and female port 9.5Fr 30cm
CTU14030 ConnectingtubewithmaleLuerandfemaleport(accepts3/4”hosebarb),14Fr, 30cm *Commonly used with Heimlich One-Way Valve (HV100)
Bag to Bag Connectors
Features:• Adoublespikedconnectinglinethatallowstheadditionofasecondfluidbagtoan
existingfluidbag,whengreatervolumesoffluidarerequiredandchangingthebagis not possible. This may occur in a practice overnight where an animal may be onIVfluids,butthereisnostafftheretoswitchovertoanewbag.Oneendofthespikedconnectingtubeisinsertedintothebottomofthefirstfluidbagandthentheother end of the spiked connecting tube is inserted into the front standard puncture areaofthesecondfluidbag.Thesecondbagshouldbehungslightlyhigherthanthefirstbagandtheclampshouldbeleftopensothatthefluidwouldflowfreelyfromthesecondbagtothefirstbagwhenrequired.
• Sterile, Polyvinyl
Code DescriptionLACTEC3 Double-ended spiked connecting tube, 24Fr (8mm O.D.), 40cm long with
two non-vented spikes and G Clamp
Wide Bore Infusion Set (No Chamber)
Features:• Singlespike,wideboresetforrapidfluidadministrationwithmaleluerlockconnector.• Sterile
Code DescriptionLACTEC1 Single, wide bore tubing with spike, 24Fr (8mm O.D.), 200cm length tubing
with rotating cuff male Luer lock
FLUID ADMINISTRATION & THERAPY
SURGIVET™ CRITICAL CARE CONSUMABLES 13
Spiked Wide Bore Infusion Sets
Features:• Completespikedwideboretubingsetstoaidindeliveryoffluidstolargeranimals
eg. horses.• Coiled tubing to prevent kinking or twisting of line.• Sterile, polyvinyl
Code DescriptionLACTEC2 Single, wide bore tubing with connector spike, 24Fr (8mm O.D), 450cm
total tubing length, large in-line chamber, roller clamp, injection port and rotating cuff male Luer lock
LACTEC4 Double, wide bore tubing with connector spike, 24Fr (8mm O.D.), 450cm total tubing length, large in-line chamber, roller clamp, injection port and rotating cuff male Luer lock
Subcutaneous Catheter Sets
Features:• Thiscathetersetisusedinpatientsthatneedfrequentfluidtherapyor
subcutaneous medication administration. It is placed under the skin typically lateral to the spine and in between the scapulas of both cats and dogs. When used, this reduces the amount of repeated pokes with a needle that the patient has to endure. Patients can be sent home with the catheter, making it easier for ownerstoadministerfluidsandmedicationstotheirpetwithouthavingtouseneedles.Thisalsoeliminatesrepeatedvisitstothevet’sofficeforsupplementalfluidsforthesetypesofpatients.Canbeusedforupto1year.Theshortstyletreinforces the catheter when not in use and cap prevents contamination.
• Sterile
Code French Size Length (cm)FSQ712 7 12
FSQ718 7 18
FSQ725 7 25
FLUID ADMINISTRATION & THERAPY
SURGIVET™ CRITICAL CARE CONSUMABLES14
Vet-Core™ Biopsy Needles
Features:• The Vet-Core™ Biopsy Needle is a device that provides a one-handed technique
for obtaining a biopsy of organs such as the liver, kidneys, lung or tissue of a tumor. It may be used under direct visual control during operation, by blind insertion into an organ being palpated, by digitally stabilising a kidney through a small incision, or under ultrasound guidance.
• Etched tip enhances visualisation during ultrasound imaging.• Precise,rapidfiringspringmechanismprovidesintactcoretissuesample.• Bevelled point stylet allows easy penetration into specimen with less trauma to
surrounding tissue.• 20mm specimen notch.• Sterile
Code Gauge Length (cm)VC1409 14 9
VC1415 14 15
VC1609 16 9
VC1615 16 15
VC1809 18 9
Needles with Peel-Off Sheaths
Features:• The use of Needles with Peel-off sheaths promote easy and accurate placement of
catheters such as oesophagostomy tubes and central venous catheters. An alternate description would be that the Needles with Peel-off sheaths allow for an easy conduit into the vessel for guiding and placement of the catheter.
• PTFE Peel-off Sheaths• Radiopaque needle and sheath• Sterile
Code Gauge Sheaths NeedleNPOS775 7 5 1
NPOS875 8 5 1
NPOS1055 10 5 1
NPOS1570 15 5 1
NPOS1770 17 5 1
Equine Sacral Joint Needle
Features:• Needle used for injection or aspiration of the sacral joint.• The inner stylet matches the bevel tip of the outer needle.• Sterile• Echogenic tip on outer cannula
Code Gauge Length (cm)ESJN1525 15 25
NEEDLES
SURGIVET™ CRITICAL CARE CONSUMABLES 15
Equine Uterine Flushing Catheter
Features:• TheEquineUterineFlushingCatheterisusedforflushingandirrigation,
administration of medications, embryo collection and transfer.• Silicone tube is reusable and autoclavable.• Clamp provided to control delivery.• Sterile
Code Tube I.D. (mm)
Tube O.D. (mm)
French Size Length (cm)
VEUF15 8 12 36 150
VEUF80 8 12 36 80
Equine Fluid Delivery System
Features:• The Equine Fluid Delivery System is commonly used with the Equine Uterine Flushing
Catheter.Itcanalsobeusedinmanyotherapplicationsforanytypeoffluiddelivery.• Silicone tube is reusable and autoclavable.• 5’3”Siliconetubeincludesshutoffclampandbellshapedbottleadaptorwith
medication port/vent.• Sterile
Code Tube I.D. (mm)
Tube O.D. (mm)
French Size Length (cm)
VEFD16 8 13 39 160
REPRODUCTION
SURGIVET™ CRITICAL CARE CONSUMABLES16
Slippery Sam™ Tomcat Urethral Catheters
Features:• ThisPTFE(polytetrafluorethylene)coatedcatheterisusedtoeliminatetheurethral
obstructionandallowdrainageoradministrationoffluids.PolytetrafluoroethyleneisasyntheticfluoropolymerthatisbetterknownbythetradenameTeflon®.ThesignificanceofthePTFEisthatitmakesthecatheterlubricious,makingiteasiertoinsert into the urethra. This catheter is to be used short or medium term only, until a regular tomcat urethral catheter can be placed if necessary.
• Rigid and slippery for easy, atraumatic placement. No stylet required. • Endholeordistalsideholesfordrainageoradministrationoffluids.• Lowprofilesiliconehubwithsutureholeswillaidinpreventingcatheterbeing
removed prematurely by the cat. • The hub will accept a standard luer lock syringe, an IV bag for closed collection or a
Little Herbert™.• Sterile
Code French Size Length(cm)
Side Holes
Endhole Design
TTM3011OE 3.0 11 None Open
TTM3511OE 3.5 11 None Open
TTM3514OE 3.5 14 None Open
TTM3518OE 3.5 18 None Open
TTM3511 3.5 11 Yes Closed
TTM3514 3.5 14 Yes Closed
*TTM3011OE is commonly used in ferrets
Tomcat Urethral Catheters (Silicone)
Features:• This silicone catheter can be used for long term or upon removal of the Slippery
Sam™Catheter.Itallowsdrainageoradministrationoffluids.Thesiliconeallowsit to be left in long term because there is minimal irritation to the urethral mucosa or bladder wall. It is available in closed or open end hole design. The open ended design is most commonly used if there are any stones or paste present in the bladder.
• A wire guide stylet to aid in introduction is also provided with the catheter because of the softness of the silicone.
• Lowprofilesiliconehubwithsutureholeswillaidinpreventingthecatheterbeingremoved prematurely by the cat.
• The hub will accept a standard luer lock syringe, an IV bag for closed collection or a Little Herbert™.
• Reusable & Autoclavable• Sterile.
Code French Size Length(cm)
Side Holes
Endhole Design
TM35 3.5 12 Yes Closed
TM35OE 3.5 12 Yes Open
UROLOGY
SURGIVET™ CRITICAL CARE CONSUMABLES 17
Little Herbert® Luer Lock Adaptor
Features:• Allowsforfirmconnectionofdrainagelinestourinarycatheterswithoutinterfering
with the comfort factor. Sterile
Code DescriptionTCLLA StandardfemaleLuerlockfittingwithbarbedinsertionend
UROLOGY
SURGIVET™ CRITICAL CARE CONSUMABLES18
FOLEY CATHETERS (SILICONE)
Foley Catheters allow continuous drainage from the urinary bladder and are also for contrast studies of the urodenital tract. Silicone’s inert and non-irritating properties allow for medium to long term placement of these catheters. Silicone is less irritating than other materials to the mucosal lining of both the urethra and the urinary bladder. These catheters vary in length; the longer ones are typically used for males and the shorter ones for females.
Theballoonsonthesecathetersshouldbefilledwithsterile water only and aid in keeping the catheter in place. The balloons are porous toairandwillnotstayinflatedwhenplacedinsideanybodycavity.Sterilesalineshould not be used either. The saline will eventually form crystalsinsidetheballoonandwillcausedamagetoit,causingittoleakorblocktheinflationline.
Forcontraststudies(radiographicstudies),thecatheterisinsertedintotheurethra,theballooninflatedwithsterilewater,andanionicorganic iodide contrast medium is injected into the catheter while a series of radiographs are taken. These contrast studies are typically performed to look for narrowing of the urethra, or tumors in the urinary bladder.
Economy ClearView Foley Catheters (Silicone)
Features:• Closed-end silicone catheter with distal balloon. Ribbed balloon provides even
inflationandaidsinretainingthecatheterinsidethebladder.• Recommended only to be used with PTFE coated wire guides• Sterile• Reusable and autoclavable• Colour coded for easy reference.
Code French Size Length(cm)
Balloon Size (cc)
Colour
CFC530 5 30 1 Pink
CFC555 5 55 1 Pink
CFC630 6 30 1.5 Brown
CFC655 6 55 1.5 Brown
CFC830 8 30 3 Blue
CFC855 8 55 3 Blue
CFC1030 10 30 3 Black
CFC1055 10 55 3 Black
CFC1255 12 55 5 White
CFC1455 14 55 30 Green
CFC1655 16 55 30 Orange
CFC1855 18 55 30 Red
CFC2065 20 65 30 Yellow
CFC2265 22 65 30 Purple
UROLOGY
ClearView PTFE Coated Wire Guide
Code Outer Diameter (in)
Length (cm)
For use with CFC Catheters
TCGW2170 0.021” 70 5 Fr & 6 Fr
TCGW3570 0.035” 70 8 Fr
TCGW3870 0.038” 70 10 Fr
TCGW38180 0.038” 180 10 Fr
SURGIVET™ CRITICAL CARE CONSUMABLES 19
Premium Foley Catheters (Silicone)
Code French Size Length(cm)
Balloon Size (cc)
Colour
FC630 6 30 2 Grey
FC655 6 55 2 Grey
FC830 8 30 5 Blue
FC855 8 55 5 Blue
FC1030 10 30 5 Black
FC1055 10 55 5 Black
FC1230 12 55 10 White
FC1255 12 55 10 White
FC1455 14 55 10 Green
FC1655 16 55 20 Orange
FC1855 18 55 20 Red
FC2065 20 65 30 Yellow
FC2265 22 65 30 Purple
SFC2875Stallion
28 75 50
SFC28100 Stallion
28 100 50
Features:• Closed-end silicone catheter with distal balloon cuff used for intermittent drainage of urine from
the bladder or contrast studies of urogenital tract.• Balloon aids in retaining the catheter inside the bladder• Recommended to be used with wire guide stiffening stylets.• Reusable and autoclavable• Silicone• Atraumatic• Radiopaque• Colour coded for easy size reference.
UROLOGY
Wire Guide Stiffening Stylets
Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable
Code Outer Diameter (in)
Length (cm)
For use with FC Catheters
WG1770 0.017” 70 5 Fr & 6 Fr
WG2560 0.025” 60 6 Fr
WG3860 0.038” 60 8 Fr
WG4560 0.045” 60 10 Fr & 12 Fr
SURGIVET™ CRITICAL CARE CONSUMABLES20
Central Venous Seldinger Catheter Sets
Code Feline DescriptionCVS301J Set consists of 3 Fr polyurethane catheter, 8cm long, 4 Fr vessel dilator,
30cm“J”wireguideand21ga,4cmlongneedle
CVS401J Set consists of 4 Fr polyurethane catheter, 10cm long, 5 Fr vessel dilator, 50cm“J”wireguideand20ga,4cmlongneedle
Central venous catheters (aka central venous lines) are used for venous pressure monitoring, collecting blood samples, and administering drugsand/orfluidstopatientsthatrequirelongtermtherapy.Thecatheteristypicallyplacedintothejugularvein,butotherperipheralsitesmay be used. These catheters are made from polyurethane which is soft enough to reduce the chance of injury and irritation to the wall of the blood vessel. The softness of the catheters also reduces the risk of causing a blood clot formation on the wall of the catheter. The cathetercanbeleftinthepatientforuptotwoweeksifpropercathetermaintenanceisperformed(regularflushingwithheparinizedsalineand proper protective dressing). Suture wings can be secured to the skin with sutures. Supplied sterile.
Features:• Used for venous pressure monitoring, blood sampling and administration of drugs
andfluids.• Intended to be introduced using the Seldinger Introduction Technique.• Use of the `J’ Wire Guide that is included allows you to pass the catheter into
specificvesselswhichcannotbeachievedwithacatheteralone.• Sterile
Code Canine DescriptionCVS501J Set consists of 5 Fr polyurethane catheter, 15cm long, 6 Fr vessel dilator,
50cm“J”wireguideand18ga,7cmlongneedle
Central Venous Peel-Off Sheath Catheter Sets
Features:• Central venous catheter introduced using a Peel-off sheathed needle.• The Peel-off sheath pre-loaded on the access needle allows percutaneous
introduction of the venous catheter, following direct venipuncture and removal of the needle cannula.
• After positioning the catheter, the sheath is peeled away.• Sterile
Code Canine DescriptionCVP308 Setconsistsof3Frpolyethylenecatheter8cmlong,matchedflexible
obturator, 19 ga, 7cm long Peel-off sheath needle and 10ml syringe
CVP4010 Setconsistsof4Frpolyethylenecatheter10cmlong,matchedflexibleobturator, 17 ga, 7cm long Peel-off sheath needle and 10ml syringe
CVP5015 Setconsistsof5Frpolyethylenecatheter15cmlong,matchedflexibleobturator, 15 ga, 7cm long Peel-off sheath needle and 10ml syringe
CENTRAL VENOUS CATHETERS
SURGIVET™ CRITICAL CARE CONSUMABLES 21
Central Venous Peel-Off Sheath and Proximal Extension Catheter Sets
Code Canine DescriptionCVP70255 7 Fr polyurethane catheter 25cm long with 5cm proximal catheter
extension,amatchedflexibleobturator,a13ga,7cmlongPeel-offsheathneedle and a 10ml syringe
CVP85255 8.5 Fr polyurethane catheter 25cm long with 5cm proximal catheter extension,amatchedflexibleobturator,a12ga,7cmlongPeel-offsheathneedle and a 10ml syringe
Features:• Central venous catheter introduced using a Peel-off sheath needle.• The Peel-off sheath pre-loaded on the access needle, allowing percutaneous
introduction of the venous catheter, following direct venipuncture and removal of the needle cannula.
• After positioning the catheter, the sheath is peeled away. • Catheter can be trimmed if a shorter length is required.• Proximal extension assists with catheter manipulations after placement.• Sterile
CENTRAL VENOUS CATHETERS
SURGIVET™ CRITICAL CARE CONSUMABLES22
Chest Drainage Tubes
Code Tube I.D. (mm)
Tube O.D. (mm)
French Size
Length (cm)
Side Holes Over Distal of Catheter
CT12 2.3 4 12 42 5cm
CT14 2.9 4.7 14 42 7cm
CT20 4.0 6.6 20 42 10cm
CT30 7.0 10 30 42 12cm
Features:• Chestdrainagetubescanbeusedforthedrainageofairorfluid(hemo-,chylo-,pyo-,
pneumothorax).Hemothoraxisbloodinthethoraciccavity.Chylothoraxismilkyfluidconsisting of lymph and fat in the thoracic cavity. These tubes are placed by making an incision with a scalpel and bluntly dissecting through the muscle layers into the thoracic cavity.
• It is recommended to use with Metal Stiffening Stylets (MSS). The metal stiffening stylets are designed to be shorter than the catheter because the silicon tube will bunch up on itself when being pushed through the skin.
• Markings at 2 and 4cm from the last hole aid in correct positioning of catheter.• Multiplelargeholesfordrainingviscousfluids.• Reusable and autoclavable, supplied sterile• Silicone, reusable and autoclavable• Radiopaque• Sterile
* Product code PFLLA is recommended for use with CT12, CT14 and CT20* Product code PFLLAL is recommended for use with CT30
Pneumothorax Sets
Features:• Pneumothorax sets are used to treat tension or spontaneous pneumothorax which
isairinthethoraciccavity.Airinthethoraciccavitymakesitmoredifficultfortheanimal to breathe. Tension pneumothorax occurs when air escapes into the pleural cavity from a bronchus, but cannot regain entry into the lungs. This continuous increase of air pressure in the pleural cavity advances the collapse of the lung. Spontaneous pneumothorax is of unknown cause. The polyurethane catheter is placed with a direct puncture between the 7th and 8th rib. It is always important that when the catheter is introduced that there is a closed stopcock on the end opposite that is being inserted to stop the intake of air into the thoracic cavity. It works best to pull the skin forward before puncture, the skin will help seal off an external air from entering once it is released. After the tube is secured, bandaged, suction will be applied via a continuous suction unit, manual syringe technique or via a Heimlich One-Way Valve (HV100)
• Design allows rapid placement in an emergency.• Luer lock connector on end is ideal for hooking up to suction or Heimlich One-Way
Valve.• Can stay in for about 15 days.• Radiopaque• Sterile
Code French Size Catheter Length (cm)
Introduction Needle Stylet Length
TPT815 8.3 35 15
TPT1020 10 40 20
WOUND MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES 23
Multi-Purpose Drainage Tube
Features:• The Multi-Purpose Drainage Tube is used as an extension to indwelling drainage
catheters or pressure lines. It can be used to connect urinary catheters to closed collection bags, drainage tubes to suction, nasal catheters to oxygen etc. The polyvinyl chloride (PVC) tube consists to two tapered adapters of different sizes, tubingwithluerlockfittingsandastopcock.Itcanbeusedasawholeor disassembledtousetheindividualfittings.
• Sterile
Code French Size Length (cm)APFT1455 14 55
Thoracic Drainage Catheter
Features:• Thispolyvinylcathetercanbeusedforthedrainageoffluidfromthethoracicor
abdominal cavity. This catheter is more rigid than the CT and can be introduced with a puncture technique rather than a blunt dissection like the CT. The trocar for this catheter is inserted into the side of the catheter rather than travel down the entire catheter. This makes it much easier to hold in one’s hand. The user can have the end of the trocar in the palm of their hand to easily and more safely place the catheter with a puncture technique.
• Short, thick trocar for controlled introduction of the catheter.• Extra large side holes over a short distance on the distal end of the catheter.• Slightly blunted tip that aids in entering pleural lining.• Luerlockfittingonendcanbeconnectedtoasuctionapparatus.• Radiopaque• Sterile
Code French Size Catheter Length (cm)
Introduction Needle Stylet Length
TPT1230 12 30 12
TPT1630 16 30 12
Two-Part Drainage Catheter Sets
Features:• ThisPolyurethanecathetercanbeusedforthedrainageoffluidfromthethoracic
or abdominal cavity. It is generally introduced using a direct puncture technique, however it can also be introduced via dissection and a blunt trocar. Once the distal end of the trocar stylet and catheter are within the cavity, the catheter is detached from the trocar stylet and advanced off the trocar stylet and into the position.
• Multiple large side holes facilitate drainage of pus, blood or chyle.• Radiopaque• Sterile
Code French Size Catheter Length (cm)
TDC1030 10.2 30
TDC1230 12 30
WOUND MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES24
Heimlich One-Way Valve
Features:• A one way valve to be used in conjunction with a chest tube or pneumothorax set
forthereliefofpneumothoraxinanimalsusuallyover10kg.Aircanonlyflowinonedirection through the valve. As the animal breathes in, the air in the pleural cavity is forced out of the chest tube and through the Heimlich valve. The pneumothorax will thereforeresolveitself.Itisstronglyrecommendednottousethisdeviceiffluidispresent in the chest because the duck bills in the valve will stick together.
• The HV100 Heimlich Valve comes complete with the valve and connecting tube ready to connect to a variety of chest tubes used to treat pneumothorax.
• Sterile
Code DescriptionHV100 Heimlich One-Way Valve
Pericardiocentesis Catheter Set
Features:• Thiscathetersetisusedtodrainfluidfromthepericardialsac.TheSeldinger
technique offers a greater level of safety than direct needle puncture. With the animal in lateral recumbency, the needle is introduced through the fourth intercostal space and should be advanced slowly towards the heart. Resistance will be felt from the pericardium, then a sudden release as it is penetrated. If the needle touches the myocardium, premature ventricular contractions will be seen on an ECG monitor. Once in place, thread the wire guide through the needle into the pericardial sac and remove the needle. The dilator can be used to open up a tract through the skin if necessary. The catheter pigtail is then unrolled over the thumb and threaded onto the wire guide and down into the pericardial sac. When thewireguideisremoved,thepigtailconfigurationretainsthecathetertipwithinthe sac.
• FEP(fluorinatedethylenepropylenecopolymer)• Sterile
Code DescriptionPCS911 Set includes 8.2 Fr, 20cm long catheter with six distal side holes, an 18 ga,
7cmlongintroductionneedleanda0.038”diameter,60cmlongwireguide
Pericardiocentesis Needle & Catheter
Features:• Usedtodrainfluidfromthepericardialsac.• FEP(fluorinatedethylenepropylenecopolymer)catheter.• Sheath and needle are inserted into vessel together.• Sterile
Code French Size Length(cm)
Gauge Needle Length (cm)
PCS1415 8.2 15 14 18
WOUND MANAGEMENT
SURGIVET™ CRITICAL CARE CONSUMABLES 25
WOUND MANAGEMENT
Broncho-Alveolar Lavage Catheter (Silicone)
Features:• TheBALcatheterisusedforlunglavageand/orcollectionofaspecimenfromspecific
lungfields.Thiscatheterisusedonanimalsundersedation,mostcommonlyhorses.Thecatheterisequippedwithaballoonattheendthatcanbeinflatedtopreventretrogradefluidflowandaproximaltwo-wayfittingallowssimultaneousconnectionforboth irrigation and aspiration.
• Reusableandautoclavable-however,theplasticproximaltwo-wayfittingmustberemoved.
• Replacement balloon cuffs (RK7) and silicon adhesive (ADH2) are available.• Replacementinflationlines(RILS)available.• The three-way stopcock (STC3WSLIP) provided is not autoclavable and intended for
one time use.• Sterile
Features:• Usedforthelavageofselectedsegmentsofthelungfields.• Polytetrafluroethylene(PTFE)catheterwithendholeandfemalelueratthe
opposite end.• Non-autoclavable (best to use ethylene oxide sterilisation).• Radiopaque• Sterile
Code French Size Tube I.D.(mm)
Tube O.D. (mm)
Length (cm)
BAL240 30 3 11 240
BAL300 30 3 11 300
Canine Broncho-Alveolar Lavage Catheter
Code French Size Length (cm)CBAL5190 5 190
CBAL6125 6 125
Guttural Pouch Endoscopic Flushing Catheter
Features:• The catheter is endoscopically guided for the lavaging of lungs or the guttural pouch
toremovedebris.Thegutturalpouchisalargeair-filledsacinthenarrowchannelthat connects the nasopharynx to the middle ear in the horse. The paired sacs cause swelling in the region below the ear when distended. Several large vessels and nerves run over this area and are susceptible to disease of the pouch. This is usually a quick procedure where the catheter is not left it.
• Visual indicators at 2.5, 5 and 7.5cm from the distal tip aid in introduction.• PTFE catheter• Sterile
Code French Size Length (cm) Distal Tip MarkingsEFC5170 5 170 Yes
EFC5250 5 250 Yes
EFC6250 6 250 Yes
EFC6330 6 330 Yes
EFC7250 7 250 Yes
SURGIVET™ CRITICAL CARE CONSUMABLES26
Peritoneal Lavage Catheter
Features:• This catheter is used to infuse and withdraw rinsing solutions in body cavities in
cases of blunt trauma or therapeutic use. The set consists of a catheter with six distal side holes, introduction needle and a wire guide. Peritoneal lavage may be indicated for a case of pancreatitis, peritonitis, hemoperitoneum, uroperitoneum etc. This catheter is almost identical to the PCS911, except it is bent 45 degrees at the distal tip.
• FEP(fluorinatedethylenepropylenecopolymer)• Sterile
Code DescriptionPLS100 Set includes 8.2 Fr, 20cm long catheter with six distal side holes, an 18 ga,
7cmlongintroductionneedleanda0.038”diameter,60cmlongwireguide
Continuous Suction Bulbs
Features:• Continuous suction bulbs allow short-term suction to be applied to body cavities,
enablingthedrainageofeitherairorfluid.Sinceitisacloseddevice,thereisnomess associated with it like there is with penrose drains etc.
• Clearsoyoucannotethecharacteristicsofthefluidthatyouarecollecting.• Similar to the human drainage systems that are pre-packaged with a continuous
suction bulb but only one type of tubing. Our Suction Bulbs are sold separately to be used with your choice of tubing.
• Ideal for use in small animals.• Side tab allows the device to be anchored to the body by either bandage or tape.• Onewayvalveandluerlockfitting.• Silicone• Sterile
Code SizeGSB100 100 cc
GSB150 150 cc
GSB400 400 cc
WOUND MANAGEMENT
Closed Wound Vacuum Drains (Silicone)
Features:• Used for post-operative drainage. • May be used in conjunction with closed wound vacuum devices.• Very popular wound drain.• Radiopaque• Ideal for use with Continuous Suction Bulb shown on page 27• Sterile
Code Drainage Tube Length (cm)
Width (mm)
Multiple Fenestrations
Rounded Conn. Tube (cm)
CWVD0720 20 7 Yes 60
CWVD1320 20 13 Yes 60
SURGIVET™ CRITICAL CARE CONSUMABLES 27
WOUND MANAGEMENT
Fenestrated Catheter Wound Drain
Code French Size Length (cm)FCWD25 8 25
Features:• Suitable for post-orthopaedic wound drainage.• Polyurethane Catheter• Radiopaque• Sterile
Features:• May be trimmed or used as one piece for surgical wound drainage. • Drain can be split along length or trimmed to suit individual requirements.• Reusable and autoclavable• Radiopaque• Autoclavable• Sterile
Flexi-Drain Multi-Purpose Wound Drain (Silicone)
Code Lumen Diameter (mm)
Drainage Tube Length (cm)
Joined Catheter Lumens
WD1240 3 40 12
SURGIVET™ CRITICAL CARE CONSUMABLES28
Stopcocks (Sterile)
OWS100 STC3WSTC1W STC3WSLIP
Code DescriptionOWS100 One-way plastic stopcock, female Luer lock to male Luer lock
STC3W Three-way plastic stopcock, two female Luer locks to male Luer lock with right side arm
STC1W One-way plastic stopcock, female Luer slip to male Luer slip
STC3WSLIP Three-way plastic stopcock, two female Luer slips to one male Luer slip
PFLLAL PMLLALPFLLA P412 & P79
Theseadaptors,alsoknownas“ChristmasTrees”facilitatetheconnectionofdifferentdiametertubingtoluerlockdevicessuchassyringesorcatheterfittings.Exampleswouldbesiliconechesttubestosuctionornasogastrictubestooxygentubingforintranasaloxygendelivery.The PFLLAL is the most popular adapter and is commonly used to assist syringe feeding via a silicone nasogastric tube or a PEG tube, injection of a foley catheter for bladder studies, or connecting a foley to a closed collection bag. The double ended variety adaptors allow different diameter tubing to be joined together.
Multi Purpose Tubing Adaptors (Sterile)
Code DescriptionPFLLA Female Luer lock to tapered catheter end - Fitting accepts 10-20 Fr I.D.
PFLLAL Female Luer lock to large tapered catheter end - Fitting accepts 20-40 Fr I.D.
PMLLAL Male Luer lock to large tapered catheter end - Fitting accepts 20-40 Fr I.D.
P412 Double-ended tapered connector - Fitting accepts 4-12mm I.D.
P79 Double-ended tapered connector - Fitting accepts 7-9mm I.D.
CONSUMABLE PRODUCT ACCESSORIES
SURGIVET™ CRITICAL CARE CONSUMABLES 29
CONSUMABLE PRODUCT ACCESSORIES
Injection Ports (Sterile) Luer Lock Plug (Sterile)
VIP2 LLP100
Code DescriptionVIP2 Luer lock cap to allow injection of solutions through cap
LLP100 Luer lock plug to occlude female Luer lock
Clamps (Sterile)
CLAMPWS CLAMPWL
Code DescriptionCLAMPWS Clamp to occlude drainage catheter tubing - For use with tubing up to 5mm O.D.
CLAMPWL Large clamp to occlude drainage catheter tubing - For use with tubing 12.7 - 16mm O.D.
Fixation Disc (Sterile)
Silicone Adhesive (Non-Sterile)
Features:• Recommendedforusewhenrepairingsiliconecuffsandinflationlineson
endotracheal tubes and BAL Tubes.• 2.8oz tube of silicone adhesive
Code DescriptionADH2 Silicone Adhesive 2.8oz
Code DescriptionFD100 Silicone Fixation Disc
Features:• Siliconefixationdisc• Used to stabilise percutaneous drainage catheters.• Sterile
SURGIVET™ CRITICAL CARE CONSUMABLES30
Endotracheal Tube Stylet with Stopper
Features:• Stainless steel endotracheal tube stylet with silicone stopper• Non-sterile• Autoclavable• Malleable
Code Fits (mm)VSTYLSM 2.5 - 5.5
VSTYLLG 5.5 - 9.5
ClearView PTFE Coated Wire Guide
Features:• Recommended to be used with Economy Clearview Oral/Nasal Oxygen/Feeding
Tubes and Clearview Foley Catheters. • Sterile• Autoclavable
Code Outer Diameter (in)
Length (cm)
For use with CFC Catheters &
Feeding TubesTCGW2170 0.021” 70 5 Fr & 6 Fr
TCGW3570 0.035” 70 8 Fr
TCGW3870 0.038” 70 10 Fr
TCGW38180 0.038” 180 10 Fr
Wire Guide Stiffening Stylets
Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable
Code Outer Diameter (in)
Length (cm)
For use with FC Catheters
WG1770 0.017” 70 5 Fr & 6 Fr
WG2560 0.025” 60 6 Fr
WG3860 0.038” 60 8 Fr
WG4560 0.045” 60 10 Fr & 12 Fr
CONSUMABLE PRODUCT ACCESSORIES
SURGIVET™ CRITICAL CARE CONSUMABLES 31
Features:• Recommended to be used with Premium Foley Catheters. • Sterile• Autoclavable
CONSUMABLE PRODUCT ACCESSORIES
Metal Stiffening Stylets
Features:• Solid stainless steel rod / stiffening stylet• Recommended for use with Chest Drains• Autoclavable• Non-sterile
Code Outer Diameter (mm)
Length (cm)
For use with CT Catheters
MSS12 1.3 40 12 Fr
MSS14 2.3 40 14 Fr
MSS20 3.2 40 20 Fr
MSS30 4.7 45 30 Fr
Stainless Steel Threaded Wire Guides
Features:• Non-sterile• Autoclavable
Code Outer Diameter (mm)
Length (cm)
GTI070TW 1 70
GTI110TW 1 110
Introduction Tubes
Features:• Non-sterile• Autoclavable
Code Outer Diameter (mm)
Length (cm)
GTI545IT 5 45
GTI9545IT 9.5 45
SURGIVET™ CRITICAL CARE CONSUMABLES32
AAdaptor Airway (ETC, 32121B) 6 Little Herbert® Luer Lock Adaptor (TCLLA) 17Adhesive, Silicone (ADH2) 29
BBag to Bag Connectors (LACTEC3) 12Biopsy Needle, Vet-Core (VC) 14Broncho-Alveolar Lavage Catheter (BAL & CBAL) 25
CCatheter Broncho-Alveolar Lavage Catheter (BAL & CBAL) 25 Economy ClearView Foley Silicone (CFC) 18 Equine Urine Flushing (VEUF) 15 Guttural Pouch Endoscopic Flushing (EFC) 26 Pericardiocentesis Needle, Set (PCS1415) 24 Set (PCS911) 24 Peritoneal Lavage (PLS100) 26 Premium Foley Silicone (FC, SFC) 19 Slippery Sam™ Tomcat Urethral (TTM) 16 Subcutaneous Set (FSQ) 13 Thoracic Drainage (TPTL) 23 Tomcat Urethral Silicone (TM) 16 Two-Part Drainage Set (TDC) 23Central Venous Catheter Set Peel-Off Sheath (CVP) 20 Peel-Off Sheath & Proximal Extension (CVP) 21 Seldinger (CVS) 20Chest Drainage Tube (CT) 22Clamps (CLAMPW) 29ClearView Economy Oral/Nasal Feeding Tube (CFT) 9 Foley Catheter (CFC) 18 PTFE Coated Wire Guide (TCGW) 30Closed Wound Vacuum Drain Silicone (CWVD) 26Connecting Tube (CT, CTU) 12Connectors Bag to Bag (LACTEC3) 12 Endotracheal Tube 6Continuous Suction Bulbs (GSB) 26Cuffed Endotracheal Tubes 4-7Cuffed Wire Reinforced Endotracheal Tube (V35W, JET) 4
DDrain Closed Wound Vacuum Silicone (CWVD) 26 Fenestrated Catheter Wound (FCWD25) 27 Flexi-Drain Multi-Purpose Wound (WD1240) 27
EEconomy ClearView Foley Silicone (CFC) 18 ClearView Economy Oral/Nasal Feeding Tube (CFT) 9Equine Fluid Delivery System (VEFD16) 15 Post Anaesthetic Nasal Tube Silicone (ENAT) 7 Sacral Joint Needle (ESJN1525) 14 Uterine Flushing Catheter (VEUF) 15Endoscopic Flushing Catheter Guttural Pouch (EFC) 25Endotracheal Tube Metal Connectors (32121B) 6 Cuffed Silicone (ET) 5 Cuffed Wire Reinforced Silicone (V35W, JET) 4 Foal Silicone (FN) 7 Non-Cuffed Silicone (AT) 3 Non-Cuffed Wire Reinforced Silicone (ATR) 4 Porcine 7 Stylet with Stopper (VSTYL) 4
FFeline Oesophagostomy Tube Silicone (FET) 8 Orogastric Feeding Tube (FOT) 11Fenestrated Catheter Wound Drain (FCWD25) 27Fixation Disc (FD100) 29Foley Catheters 18-19Flexi-Drain Multi-Purpose Wound (WD1240) 27Fluid Delivery System, Equine (VEFD16) 15Foal Nasal Tube Silicone (FN) 7Foley Catheter Silicone Economy ClearView (CFC) 18 Premium (FC, SFC) 19
GGastrostomy Tube Introduction Set (GTIS) 10Guttural Pouch Endoscopic Flushing (EFC) 26
HHeimlich One-Way Valve (HV100) 24
IInfusion Sets, Wide Bore (LACTEC1, 2, 4) 12-13Injection Ports (VIP) 29Introduction Tube (GTIXXXIT) 31
LLittle Herbert® Luer Lock Adaptor (TCLLA) 17Luer Lock Plug (LLP100) 29
MMulti-Purpose Drainage Tube (APFT1455) 23 Multi-Purpose Tubing Adaptors (PFLLA,PFLLAL,PMLLAL) 28
PRODUCT INDEX
SURGIVET™ CRITICAL CARE CONSUMABLES 33
PRODUCT INDEX
NNasal Tube Silicone, Foal (FN) 7Needles Equine Sacral Joint (ESJN1525) 14 Peel-off Sheath (NPOS) 14 Vet-Core Biopsy (VC) 14Non-Cuffed Endotracheal Tube Silicone (AT) 3Non-Cuffed Wire Reinforced Endotracheal Tube Silicone (ATR) 4
OOesophagostomy Catheter (OTC) 8 Tube, Feline (FET) 8 Tube Set (OTCS) 8One-Way Valve, Heimlich (HV100) 24Oral/Nasal Oxygen/Feeding Tube Economy Clearview (CFT) 9Orogastric Feeding Tube, Feline (FOT) 11
PPeel-off Sheath Needles (NPOS) 14Peg Feeding Tube (PT) 10Pericardiocentesis Needle and Catheter (PCS1415) 24 Set (PCS911) 24Peritoneal Lavage Catheter (PLS100) 26Pneumothorax Set (TPT) 22Porcine Endotracheal Tube 7Premium Foley Silicone (FC, SFC) 19
RReplacementInflationLine(RILS,RILL) 6Repair Cuff (RK) 6
SSilicone Adhesive (ADH2) 29Slippery Sam™ Tomcat Urethral (TTM) 16Spiked Wide Bore Infusion Sets (LACTEC2, LACTEC4) 13Stopcocks (OWS, STC) 28Stylet Endotracheal Tube with Stopper (VSTYL) 4 Metal Stiffening (MSS) 31 Wire Guide Stiffening (WG) 30Subcutaneous Catheter Set (FSQ) 13Suction Bulbs, Continuous (GSB) 26
TThoracic Drainage Catheter (TPTL) 23Tomcat Urethral Catheter Silicone (TM) 16Tomcat Urethral Slippery Sam,™ (TTM) 16Tracheostomy Tube Silicone (V600XX) 7
TTube Chest Drainage (CT) 22 Connecting 12 Post Anaesthetic Nasal Silicone (ENAT) 7 Endotracheal 3-7 Feline Orogastric Feeding 11 Foal Nasal 7 Gastrostomy 10 Introduction (GTIXXXIT) 31 Multi-Purpose Drainage 23 Oesophageal 8 Oesophagostomy 8 Oral/Nasal Oxygen/Feeding 9 Peg Feeding 10 Tracheostomy 7Two-Part Drainage Catheter Set (TDC) 23
UUterine Flushing Catheter, Equine (VEUF) 15
VValve, Heimlich One-Way (HV100) 24Vet-Core Biopsy Needle (VC) 14
WWide Bore Infusion Sets (LACTEC1, 2, 4) 12-13Wire Guide ClearView PTFE Coated (TCGW) 30 Stainless Steel Threaded (GTIXXXT) 31 Stiffening Stylet (WG) 30Wire Reinforced Endotracheal Tube Non-Cuffed Silicone (ATR) 4Wire Reinforced Endotracheal Tube Cuffed Silicone (V35W, JET) 4
SURGIVET™ CRITICAL CARE CONSUMABLES34
NOTES:
SURGIVET™ CRITICAL CARE CONSUMABLES 35
NOTES:
SurgiVet™ Critical Care Consumables
Sound Veterinary equipment pty ltd p.o. box 2916, rowVille Vic 3178
unit 4, 19 cornHill St, Ferntree Gully Vic 3156 auStralia p: 1300 881 681 or +61 3 9758 2500 | F: 1300 881 682 or +61 3 9758 1881 E: [email protected] | W: www.soundveterinary.com.au