Top Banner
SCC DIRECT ASSESSMENT OF CARBON STEEL PIPELINE USING ADVANCED EDDY CURRENT ARRAY TECHNOLOGY A. RAUDE, M. SIROIS, M. BOUCHARD 4th International Conference on Pipeline Integrity Management Mumbai, India 29-30 January, 2018 Presented by: Anupam Kumar (on behalf of Angélique Raude, Surface Product Manager) 4 th ICEPIM & OMIC GAS 2018
16

4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

Dec 20, 2021

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

SCC DIRECT ASSESSMENT OF CARBON STEEL PIPELINE USING ADVANCED EDDY CURRENT ARRAY TECHNOLOGYA. RAUDE, M. SIROIS, M. BOUCHARD

4th International Conference on Pipeline Integrity Management

Mumbai, India

29-30 January, 2018

Presented by: Anupam Kumar(on behalf of Angélique Raude, Surface Product Manager)

4th ICEPIM & OMIC GAS 2018

Page 2: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

CONTENT

1. Context of Development & Objectives

2. Tangential Eddy Current Array (TECA) Technology

3. TECA for SCC Characterization

4. Deployment on Real Samples

5. Conclusion

2

Page 3: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

1.1 CONTEXT

3

• Stress Corrosion Cracking colonies in pipelines

• Specific type of fine, shallow and branched cracking

• Appear as colonies containing many individual cracks

• Represent an integrity threat for in-service pipelines causing failures around the world

• Often, occur under failed coating (no proper CP anymore)

• Cracks essentially parallel one to another and oriented perpendicular to direction of max stress on pipes

• Characterisation challenging for any examination method due to the material and defect type

Page 4: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

Current Methods

• In-line inspection

• MFL combines with UT to provide insight of regions with damaged coating, and local environment correlating to SCC

• UT and EMAT for cracks detection and discrimination capabilities

• In-ditch surface inspection

• MPI combined with UT to detection and individually depth size SCC

Objectives

• Detect surface-breaking SCC in carbon steel pipes

• Provide high resolution scan for SCC detection and sizing

• Maximize coverage and speed

• Leverage advanced imaging capabilities (C-Scan, 2D/3D)

1.2 CONTEXT - CURRENT METHODS & OBJECTIVES

4

Page 5: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

2. TECA TECHNOLOGY (1)

5

• Typical TECA response to surface breaking flaws

• EC flow perpendicular to the scan direction and are forced to pass around the longitudinal cracking by either diving underneath it or by going around its extremities

• EC are directly affected by the surface breaking cracking and their associated dimensions

Page 6: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

2. TECA TECHNOLOGY (2)

6

• Raw EC signal with constant characteristics

• Dedicated software tools

• Simplified probe normalization

• LO monitoring and compensation

• Permeability compensation

• Automated defect sizing

Lift-off

5.0mm deep2.5mm deep1.0mm deep

Lift-off

3mm

2mm

1mm 0mm

Phase shift of 3 indications with no LO

5mm deep defect with LO varying from 0 to 3mm

Page 7: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

3. TECA FOR PIPELINE INTEGRITY (1)

7

Carbon steel pipelines’ challenges & most advanced inspection solution

seam weld girth weld spiraled weld SCC / ERW

Page 8: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

3. TECA FOR PIPELINE INTEGRITY (2)

8

TECA performances for fatigue cracking in welds

• POD similar to MT and ACFM

• Detect both axial and transverse cracking in cap, toes and HAZ in one single pass

• Detect crack from 3 mm long by 0.5 mm deep

• Rapid - scanning speed 200 mm/sec

• Accurately size defect from 12.5 mm long by 1 mm deep

• Depth sizing from 0.5 to 7 mm deep

• Cope with lift-off of up to 3 mm (non-conductive paint, coating or air)

Page 9: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

3. TECA FOR PIPELINE INTEGRITY (3)

9

TECA High Resolution for SCC

• Technology adaptation

• New targeted sizing range: 0.25 to 3.0 mm deep with an accuracy of ±10%

• Large coverage: 71 mm

• Fast inspection: 600 mm/sec

• Lift-off compensation: up to 2 mm

• Conformable to a range of pipeline: from 254 mm of OD

Page 10: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

3. TECA FOR PIPELINE INTEGRITY (4)

10

Resolution Capabilities

• Solution validated on designed sample

• Section of pipe containing 11 EDM notches

• One long defect with stepped profile(defects 2 to 4)

• Some with dimension outside of solution’ssizing capabilities (defects 7, 8)

• Some placed in close proximity axially(defects 5, 6)

• Some placed in close proximitycircumferentially (defects 10, 11)

• Rapid discrimination of notches 1-2 mm apart axially

Page 11: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

3. TECA FOR PIPELINE INTEGRITY (5)

11

Resolution Capabilities (cont.)

• Circumferential resolution closer to 3 mm

• Defect profile easily assessed using sideview (defect 2-3-4) and depth assessed

• Defect 2: depth assessed at 1 mm

• Defect 3: depth assessed at 2 mm

• Defect 4: depth assessed at 3 mm

Page 12: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

4. DEPLOYMENT ON REAL SAMPLES (1)

12

Complete solution used on-site

• Fatigue crack assessment

• Accuracy on isolated crack similar to LPI

• Smallest crack detected at toe (5 mm long)

• Only microns of difference in depth sizing compare to UT measurements

• Crack colony assessment

• Colonies easily displayed with very high definition

• Good correlation with MT mapping

• Discrimination of short cracks in colonies

• Rapid assessment of deepest point

Page 13: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

4. DEPLOYMENT ON REAL SAMPLES (2)

13

Key performance

• Depth sizing accuracy

• Assessment by gradual grinding of selectedSCC zones and measurement of remaining wallthickness using UT

• Depths measured with TECA were aligned withthe remaining WT assessment: 0.8 mm withTECA, 0.67 mm with ILI and 0.7 to 0.9 mmwith grinding

• Depth sizing repeatability

• Evaluated by scanning the same area 10 times

• Measuring the deepest point each time

• Average deviation was only ±0.08 mm from theaverage depths

Page 14: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

4. DEPLOYMENT ON REAL SAMPLES (3)

14

Key performance

• Human factor

• 5 known defective areas scanned bythree different operators

• Comparison of depth sizingobtained from each dataset(deepest point at 3 selectedlocations along each scan)

• 15 points assessed

• Depths measured varied from 0.4 to1.8 mm

• Difference in depth sizing variedfrom 0 to 0.3 mm

• Maximum variation seen on colonydetected near a weld

Page 15: 4th ICEPIM & OMIC GAS 2018 SCC DIRECT ASSESSMENT OF …

5. CONCLUSION

15

• An eddy current array technique has been developedfor the detection and sizing of surface-breakingcracks in carbon steel

• The high-resolution development proved to be adapted to thesentencing of stress corrosion cracking in pipelines

• The technology provides valuable defect depth and lengthmeasurements, but also offers C-Scan imaging with real-time lift-offmonitoring and compensation

• These solutions are being used on-site and demonstrate theircapacity to mitigate potential errors caused by human factors andthose from the unrepeatable results of current methods used in ditchtoday