Top Banner
April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra 25 Ultra 45 Ultra 24 Ultra 20 M2 Ultra 40 M2 X2100 M2 X2200 M2 X4100 M2 X4200 M2 X4140 X4440 1 2 1 x Intel (2-4 cores) 1 x AMD (2 cores) 2 x AMD (2 cores) Max. Sockets 1 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 4 x AMD (2 cores) Clock Speed Clock Speed Cache 1 MB 1 MB 2 MB/ core ** 1 MB/core 1MB/core Cache 2MB 2MB 1 MB /core 1 MB /core 1MB/core (2 cores) 1MB /core Memory 8 GB 16 GB 8 GB 8 GB DDR2-667 32 GB DDR2-667 Memory 8 GB 64 GB 32 GB DDR-667 32 GB DDR-667 64 GB DDR-667 128 GB DDR-667 Graphics PCI-Ex16 for graphics PCI-Ex16 for graphics Note #1/#7 Note #1/#7 Note #2/#7 2 x 250/500/750/146/300 GB 2x73/146 GB 4 x73/146 GB 8x73/146 GB 8 x73/146 GB 4 x 80/250GB 4 x 250/146GB SATA-II; SAS (146/300) 73GB(15K); 10KSAS (R0,1) 73GB(15K); 10KSAS (R0,1) SATA(80) /SAS(250) SATA(250) /SAS(146) PCI I/O Slots 2 PCI-Ex8 2 PCI-Ex8 2 PCI-Ex8 4 PCI-Ex8, PCI-X 2PCI-Ex8;PCI-Ex16 4PCI-Ex8;PCI-Ex4;PCI-Ex16 USB ports 6 USB, 2FW 6 USB, 2FW 6 USB, 2FW 6 USB,2FW 8 USB,2FW 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000 PCI I/O Slots Rack Units 1U 1U 1U 2U 1U 4U Notes No built-in graphics On-board 2D graphics R0,1 for W-XP only Notes on-board 2D VGA; SP; #7 H Category F H F E E Category E E E (note#5) E E E Sun Fire X64 Servers *** Sun Fire X4950 Sun Blade Systems X4150 X4450 X4600 M2 X4500 Sun Blade 8000 Sun Blade 8000 P X8420 X8440 X8450 Sun Blade 6048 Sun Blade 6000 Max. Sockets 2 x Intel (2-4 cores) 4 x Intel (2-4 cores) 8xAMD (2cores) 2-4xIntel (2-4cores) Clock Speed 3.0 (8222) Cache 4 – 12 MB 4 – 8 MB ** 1 MB /core 1 MB/core 1 MB/core 1 MB/core 4-12 MB Memory 64 GB FB-DIMM 128 GB FB-DIMM 128/256 GB 16 GB 64 GB DDR2 64/128 GB DDR2 8x73/146GB 4 x 73/146 GB 48x250/500/750GB/1TB 2x73/146/80GB 2x73/146/80GB 2x73/146/80/200GB 10KSAS (R0,1) 73GB(15K); 10KSAS (R0,1) SATA II (7.2Krpm) SAS; SATA(80) SAS; SATA(80) SAS; SATA(80/200) PCI I/O Slots 3 PCI-Ex16 2 PCI-Ex8; 4 PCI-Ex4 2 PCI-X; 6 PCI-E 2 PCI-X @133 2 PCI-Ex8 2 PCI-Ex8 2 PCI-Ex8 2 PCI-Ex8; 2 PCI-Ex4 2 PCI-Ex8; 2 PCI-Ex4 2 PCI-Ex8; 2 PCI-Ex4 Rack Units 2 U; #4 4U 4U Note #6 Note #6 Note #6 Category F F F F F F F Sun Blade Systems CMT Servers (4 Threads/core) CMT Servers (8 Threads/core) T6300 T6320 X6220 X6250 T1000 T2000 T5120 T5220 T5140 T5240 Max. Sockets 1 US-T1 (6/8 cores) 1 US-T2 (4/6/8 cores) 2x AMD (2 cores) 2xIntel (2/4 cores) 1 (6/8 cores) 1 (4/8 cores) 1 (4/6/8 cores) 1 (4/6/8 cores) 2 (4/6/8 cores) 2 (6/8 cores) Clock Speed Cache 3 MB 4 MB 1 MB/core 4 – 12 MB 3 MB 3 MB 4 MB 4 MB 4 MB 4 MB Memory 32 GB DDR2 64 GB FB 64 GB DDR2 64 GB FB-DIMM 32 GB 64 GB 64 GB FB 64 GB FB 64 GB FB 128 GB FB 4x73/146/80 GB 4 x 73/146 GB 4x73/146/80/200 GB 4x73/146/80/200 GB 4x 73/146GB 4 x 73/146 GB 8 x 73/146GB 4 x 73/146GB 8/16 x 73/146GB SAS; SATA (80) SAS 10K (R0,1) SAS; SATA (80/200) SAS; SATA (80/200) SAS 10K (#4) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1) PCI I/O Slots 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 1 PCI-E 3 PCI-E; 2 PCI-X 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM Rack Units Note #6 Note #6 Note #6 Note #8 1U 2U 1U 2U 1U 2U Category F F F F F (Solaris 10 1/06) F (Solaris 10 8/07) F (Solaris 10 8/07) ** Each pair of cores integrated with up to 4 MB of L2 Intel Advanced Smart Cache Note 4: One PCI-X slot is occupied by a SAS disk controller card installed by factory Note 9: If using on-board 10GbE port,must order XAUI card and lose an I/O slot per card Note 10: HDD capacity is set by the type of backplane installed and must be selected at the time of order (via PTO/ATO backplane opt). It cannot be changed in the field. SunRay 2(FS) / 270 Sun Ray provides instant, constant, simple and secure access to all existing applications from a centralized location, without burdensome system environment. Max. CPUs 1.34 GHz USIIIi 1.6 GHz USIIIi 2(E4400); 2.4(Q6600); 2.66(Q6700/E6750); 3(E/QX6850) 1.8(1210); 2.2(1214); 2.6(1218); 2.8(1220SE); 3(1222SE) 1.8(2210); 2.2(2214); 2.6(2218);2.8(2220); 3.0(2222) 1.8 (1210); 2.2 (1214); 2.6(1218); 2.8 (1220); 3(1222); 1.9(2347) 1.8(2210) / 2.6(2218/HE)/ 2.8(2220)/ 3(2222); 1.9(2347)/ 2.2(2354)/ 2.3(2356) 1.8(2210) / 2.4(2216) / 2.6(2218/HE) / 2.8(2220) / 3.0 (2222) /3.2(2224) 2.6(2218HE); 3.0(2222); 3.2(2224) 2.6(8218HE); 3(8222); 3.2(8224SE) Int. Disks Int. Disks 4 x 250/750GB SATA or 4x146/300GB SAS via PCIe 2x80/160/250/500/750 SATA (R0,1) or 146/300(15K) SAS 8x160/250/500/146/300/750 SATA or 146/300 SAS(15K) Int. Drive Int. Drive SR 2: 1600x1960; 2 USB. SR2FS: 1920x1200; 3 USB. SR270: 17” monitor (1280x1024); 4 USB Onboard Eth 2PCI-Ex16;1PCI- Ex8;2PCI-X 2PCI-Ex16;1PCI- Ex4;2PCI-X 2PCI-Ex16;1PCI- Ex8;1PCI-Ex1 3 PCI; 2PCI-Ex16(8); 1PCI-Ex1 1 PCI; 2 PCI-Ex16; 2 PCI-Ex8 2.5” HDDs; Aspeed AST2000 SP(VGA) Sun Modular DataCenter S20 2xAMD (2 cores) Sun Fire X4950 Streaming Switch is the central part of the Sun Streaming Systems. Each switch can stream 80K video-on-demand streams at 4MBps per stream. Sun Streaming Systems is based on the Sun Fire X4950 switch, X4500 Storage Server, X4100 Server, and Sun Streaming Software. Sun Modular Design (aka Project Blackbox) is a standard 20-feet shipping container which can be deployed virtually anywhere there is electricity, chilled water and an internet connection. (8 40RU racks; 200kW capacity) Sun Blade 8000 Modular System delivers 10 hot- pluggable Sun Blade X8400 server modules into a common 19U chassis w/ redundant mod that share I/O via passive midplane, Power and Cooling. (3+3 grid ps; 8+1 fan; 20 EM; 4 NEM) Sun Blade 8000 P Modular System delivers 10 hot-pluggable Sun Blade X8400 server modules into a common 14U chassis w/ redundant mod that share I/O via passive midplane, Power and Cooling. (3+1 grid ps; 8+1 fan; 2 NEM) 4xAMD (2 cores) 2/4xAMD (2 cores) Sun Blade 6048 Mod. System delivers 48 hot- pluggable US-T1, US-T2, AMD, & Intel based Blade servers into a 42RU rack w/ redundant mod. that share I/O via passive midplane, Power and Cooling. (1+1 grid ps; 32 fan; 96 EM; 8 NEM) Sun Blade 6000 Modular System delivers 10 hot- pluggable US-T1, AMD, Intel Based Blade servers into a common 10U chassis w/ redundant mod. that share I/O via passive midplane, Power and Cooling. (1+1 grid ps; 3+3 fan; 20 EM; 2 NEM) 1.86(E5320); 2.33(E5345); 2.66(X5355); 3.3(5260); 2(L5335; 2.33(E5410); 2.83(E5440); 3.16(X5460) 2.93(E7220); 1.86(L7345); 2.13(E7320); 2.4(E7340); 2.93(X7350) 2.4(8216) / 2.6(8218) / 2.8 (8220/ SE) / 3.0 (8222) 2.6 (285) / 2.8 (290) 2.4(8216) / 2.6(8218/HE) / 2.8(8220) 1.86(L7345); 2.4(2130); 2.13(E7320) 128 GB FB-Dimms Int. Disks Int. Drives Onboard Eth 4 GigE 4 GigE 4 GigE 4 GigE 1U; on-brd vga; #3 1.0 (6/8 cores), 1.2/1.4 (8 cores) 1.2 (4/6/8 cores), 1.4 (8 cores) 2.0 (2212); 2.6 (2218); 2.8 (2220); 3.2(2224) 3(5160); 1.6(L5310); 1.86(E5320); 2.33(E5345); 2.66(X5355); 3.3(5260); 2(L5335; 2.33(E5410); 2.83(E5440); 3.16(X5460); 3(X5450) 1.0 Ghz US-T1 1/1.2/1.4 Ghz US- T1 1.2/1.4 Ghz US- T2 1.2/1.4 Ghz US- T2 1.2/1.4 Ghz US-T2 1.2/1.4 Ghz US- T2 Int. Disks 1x80/160GB SATA or 2x73/146GB SAS Int. Drive PCI-Ex8; 2 PCI- Ex4/XAUI 2 PCI-Ex8; 2 PCI-Ex4; 2 PCI-Ex4/XAUI 1 PCI-Ex8; 2 PCI- Ex4/XAUI 2 PCI-Ex8; 2 PCI-Ex4; 2 PCI-Ex4/XAUI Onboard Eth 4 GigE 4 GigE 4 GigE; #9 4 GigE; #9 4 GigE 4 GigE; #10 Note 1: Ultra20 M2 supports ATI Rage XL, NVIDIA Quadro FX1400 or NVS 280 Graphics Accelerator; PCI-Ex16 reserved for graphics accel Note 2: 2 PCI-Ex16 for graphics cards; No built-in VGA; USB 2.0 ports; 2 Ge Ports; Integrated RAID 0,1 for Windows XP Professional 32/64 bit Intel Xeon: X model=1.3Ghz FSB, 120W CPU, quad-core; L model= 1.06GHz FSB, 50W CPU, quad-core; E5345 model=1.2Ghz FSB, 80W CPU, quad-core; E5320 model=1.06Ghz FSB, 80W CPU, quad-core; E5160=dual-core (80W CPU); 5260=dual-core; 80W CPU, L2:6MB; L5335=quad-core, 50W CPU, 2x4MB L2; E5410=quad-core, 1.6GHz FSU, 80W, 2x6MB L2; E5440=quad-core, 1.6GHz FSU, 80W CPU, 2x6MB L2; X5460=quad-core, 1.6GHz FSB, 120W CPU, 2x6MB L2; X5450=quad-core, 1.3GHz FSB, 80WCPU Note 3: If using SAS HDDs, must add a PCI-E SAS HBA Note 5: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each other Note 6: SAS=73/146GB 10K; SATA=80/200GB 5400 RPM are 2.5” HDD. Raid 0 or 1 if 2 HDDs are installed. Note 7: internal 300GB 15K SAS (3.5” HDD); Must use w/4-port SAS PCI-E HBA for X2100M2, X2200M2 &Ultra 20 M2. Use 8-port SAS PCI-E for Ultra 40 M2. X2200 M2 needs special cabling x5295A-Z ***: Sun Fire x64 servers support Solaris 10 x86 (32/64-bit)/ RHEL 3 up5+ (32-bit) & 4 up1(64-bit)/SuSe 9(64-bit) /MS 2003/2008 (32/64-bit)/ Vmware ESX (only X4150, X4450, X4100/M2, X4200/M2, X4600/M2) Note 8: If using SAS HDDs, need to order REM card Sun Hardware @Glance
4

4PCI-Ex8;PCI-Ex4;PCI-Ex16 - IASias.ch/docs/SunProductGuide_2008.pdfApril 2008 Unofficial Sun Product Guide - Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra

Apr 06, 2018

Download

Documents

truongkien
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 4PCI-Ex8;PCI-Ex4;PCI-Ex16 - IASias.ch/docs/SunProductGuide_2008.pdfApril 2008 Unofficial Sun Product Guide - Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra

April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 1

Thin Cl ients Desktops / Workstat ions Sun Fi re X64 ServersUltra 25 Ultra 45 Ultra 24 Ultra 20 M2 Ultra 40 M2 X2100 M2 X2200 M2 X4100 M2 X4200 M2 X4140 X4440

1 2 1 x Intel (2-4 cores) 1 x AMD (2 cores) 2 x AMD (2 cores) Max. Sockets 1 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 2 x AMD (2 cores) 4 x AMD (2 cores)

Clock Speed Clock SpeedCache 1 MB 1 MB 2 MB/ core ** 1 MB/core 1MB/core Cache 2MB 2MB 1 MB /core 1 MB /core 1MB/core (2 cores) 1MB /core

Memory 8 GB 16 GB 8 GB 8 GB DDR2-667 32 GB DDR2-667 Memory 8 GB 64 GB 32 GB DDR-667 32 GB DDR-667 64 GB DDR-667 128 GB DDR-667Graphics PCI-Ex16 for graphics PCI-Ex16 for graphics Note #1/#7 Note #1/#7 Note #2/#7 2 x 250/500/750/146/300 GB 2x73/146 GB 4 x73/146 GB 8x73/146 GB 8 x73/146 GB

4 x 80/250GB 4 x 250/146GB SATA-II; SAS (146/300) 73GB(15K); 10KSAS (R0,1) 73GB(15K); 10KSAS (R0,1)SATA(80) /SAS(250) SATA(250) /SAS(146) PCI I/O Slots 2 PCI-Ex8 2 PCI-Ex8 2 PCI-Ex8 4 PCI-Ex8, PCI-X 2PCI-Ex8;PCI-Ex16 4PCI-Ex8;PCI-Ex4;PCI-Ex16

USB ports 6 USB, 2FW 6 USB, 2FW 6 USB, 2FW 6 USB,2FW 8 USB,2FW 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000

PCI I/O Slots Rack Units 1U 1U 1U 2U 1U 4UNotes No built-in graphics On-board 2D graphics R0,1 for W-XP only Notes on-board 2D VGA; SP; #7

H Category F H F E E Category E E E (note#5) E E E

Sun Fi re X64 Servers *** Sun Fi re X4950 Sun Blade SystemsX4150 X4450 X4600 M2 X4500 Sun Blade 8000 Sun Blade 8000 P X8420 X8440 X8450 Sun Blade 6048 Sun Blade 6000

Max. Sockets 2 x Intel (2-4 cores) 4 x Intel (2-4 cores) 8xAMD (2cores) 2-4xIntel (2-4cores)

Clock Speed

3.0 (8222)

Cache 4 – 12 MB 4 – 8 MB ** 1 MB /core 1 MB/core 1 MB/core 1 MB/core 4-12 MBMemory 64 GB FB-DIMM 128 GB FB-DIMM 128/256 GB 16 GB 64 GB DDR2 64/128 GB DDR2

8x73/146GB 4 x 73/146 GB 48x250/500/750GB/1TB 2x73/146/80GB 2x73/146/80GB 2x73/146/80/200GB

10KSAS (R0,1) 73GB(15K); 10KSAS (R0,1) SATA II (7.2Krpm) SAS; SATA(80) SAS; SATA(80) SAS; SATA(80/200)PCI I/O Slots 3 PCI-Ex16 2 PCI-Ex8; 4 PCI-Ex4 2 PCI-X; 6 PCI-E 2 PCI-X @133 2 PCI-Ex8 2 PCI-Ex8 2 PCI-Ex8

2 PCI-Ex8; 2 PCI-Ex4 2 PCI-Ex8; 2 PCI-Ex4 2 PCI-Ex8; 2 PCI-Ex4

Rack Units 2 U; #4 4U 4U Note #6 Note #6 Note #6Category F F F F F F F

Sun Blade Systems CMT Servers (4 Threads/core) CMT Servers (8 Threads/core)

T6300 T6320 X6220 X6250 T1000 T2000 T5120 T5220 T5140 T5240

Max. Sockets 1 US-T1 (6/8 cores) 1 US-T2 (4/6/8 cores) 2x AMD (2 cores) 2xIntel (2/4 cores) 1 (6/8 cores) 1 (4/8 cores) 1 (4/6/8 cores) 1 (4/6/8 cores) 2 (4/6/8 cores) 2 (6/8 cores)

Clock SpeedCache 3 MB 4 MB 1 MB/core 4 – 12 MB 3 MB 3 MB 4 MB 4 MB 4 MB 4 MB

Memory 32 GB DDR2 64 GB FB 64 GB DDR2 64 GB FB-DIMM 32 GB 64 GB 64 GB FB 64 GB FB 64 GB FB 128 GB FB4x73/146/80 GB 4 x 73/146 GB 4x73/146/80/200 GB 4x73/146/80/200 GB 4x 73/146GB 4 x 73/146 GB 8 x 73/146GB 4 x 73/146GB 8/16 x 73/146GBSAS; SATA (80) SAS 10K (R0,1) SAS; SATA (80/200) SAS; SATA (80/200) SAS 10K (#4) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1)

PCI I/O Slots 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 1 PCI-E 3 PCI-E; 2 PCI-X2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM

Rack Units Note #6 Note #6 Note #6 Note #8 1U 2U 1U 2U 1U 2UCategory F F F F F (Solaris 10 1/06) F (Solaris 10 8/07) F (Solaris 10 8/07)

** Each pair of cores integrated with up to 4 MB of L2 Intel Advanced Smart Cache

Note 4: One PCI-X slot is occupied by a SAS disk controller card installed by factory

Note 9: If using on-board 10GbE port,must order XAUI card and lose an I/O slot per cardNote 10: HDD capacity is set by the type of backplane installed and must be selected at the time of order (via PTO/ATO backplane opt). It cannot be changed in the field.

SunRay 2(FS) / 270

Sun Ray provides instant, constant, simple and secure

access to all existing

applications from a centralized

location, without burdensome

system environment.

Max. CPUs

1.34 GHz USIIIi 1.6 GHz USIIIi

2(E4400); 2.4(Q6600); 2.66(Q6700/E6750);

3(E/QX6850)

1.8(1210); 2.2(1214); 2.6(1218);

2.8(1220SE); 3(1222SE)

1.8(2210); 2.2(2214); 2.6(2218);2.8(2220);

3.0(2222)

1.8 (1210); 2.2 (1214); 2.6(1218); 2.8 (1220);

3(1222); 1.9(2347)

1.8(2210) / 2.6(2218/HE)/

2.8(2220)/ 3(2222); 1.9(2347)/ 2.2(2354)/

2.3(2356)

1.8(2210) / 2.4(2216) / 2.6(2218/HE) / 2.8(2220) / 3.0 (2222) /3.2(2224)

2.6(2218HE); 3.0(2222); 3.2(2224)

2.6(8218HE); 3(8222);

3.2(8224SE)

Int. DisksInt. Disks

4 x 250/750GB SATA or 4x146/300GB SAS via PCIe

2x80/160/250/500/750 SATA (R0,1) or 146/300(15K) SAS

8x160/250/500/146/300/750 SATA or 146/300 SAS(15K)

Int. DriveInt. Drive

SR 2: 1600x1960; 2 USB. SR2FS:

1920x1200; 3 USB. SR270: 17” monitor (1280x1024); 4 USB

Onboard Eth2PCI-Ex16;1PCI-

Ex8;2PCI-X2PCI-Ex16;1PCI-

Ex4;2PCI-X2PCI-Ex16;1PCI-

Ex8;1PCI-Ex13 PCI; 2PCI-Ex16(8);

1PCI-Ex11 PCI; 2 PCI-Ex16; 2

PCI-Ex8

2.5” HDDs; Aspeed AST2000 SP(VGA)

Sun Modular DataCenter S20

2xAMD (2 cores)

Sun Fire X4950 Streaming Switch is the central part of the

Sun Streaming Systems. Each switch can stream 80K video-on-demand streams at 4MBps per

stream. Sun Streaming Systems is based on the Sun Fire X4950 switch, X4500 Storage Server, X4100 Server, and Sun Streaming Software.

Sun Modular Design (aka Project

Blackbox) is a standard 20-feet

shipping container which can be

deployed virtually anywhere there is electricity, chilled

water and an internet connection. (8 40RU

racks; 200kW capacity)

Sun Blade 8000 Modular System

delivers 10 hot-pluggable Sun

Blade X8400 server modules into a common 19U

chassis w/ redundant mod

that share I/O via passive midplane,

Power and Cooling. (3+3 grid ps; 8+1

fan; 20 EM; 4 NEM)

Sun Blade 8000 P Modular

System delivers 10 hot-pluggable Sun Blade X8400 server modules into a common 14U chassis w/ redundant mod

that share I/O via passive midplane,

Power and Cooling. (3+1 grid

ps; 8+1 fan; 2 NEM)

4xAMD (2 cores) 2/4xAMD (2 cores)

Sun Blade 6048 Mod. System delivers 48 hot-

pluggable US-T1, US-T2, AMD, & Intel based Blade servers into a 42RU rack w/

redundant mod. that share I/O via passive midplane,

Power and Cooling. (1+1 grid ps; 32 fan;

96 EM; 8 NEM)

Sun Blade 6000 Modular System

delivers 10 hot-pluggable US-T1, AMD, Intel Based

Blade servers into a common 10U chassis w/ redundant mod. that share I/O via passive midplane,

Power and Cooling. (1+1 grid ps; 3+3 fan;

20 EM; 2 NEM)

1.86(E5320); 2.33(E5345);

2.66(X5355); 3.3(5260); 2(L5335; 2.33(E5410);

2.83(E5440); 3.16(X5460)

2.93(E7220); 1.86(L7345); 2.13(E7320); 2.4(E7340);

2.93(X7350)

2.4(8216) / 2.6(8218) / 2.8 (8220/

SE) / 3.0 (8222)

2.6 (285) / 2.8 (290)

2.4(8216) / 2.6(8218/HE) /

2.8(8220)

1.86(L7345); 2.4(2130);

2.13(E7320)

128 GB FB-DimmsInt. DisksInt. Drives

Onboard Eth 4 GigE 4 GigE 4 GigE 4 GigE1U; on-brd vga; #3

1.0 (6/8 cores), 1.2/1.4 (8 cores)

1.2 (4/6/8 cores), 1.4 (8 cores)

2.0 (2212); 2.6 (2218); 2.8 (2220); 3.2(2224)

3(5160); 1.6(L5310); 1.86(E5320); 2.33(E5345); 2.66(X5355); 3.3(5260); 2(L5335; 2.33(E5410);

2.83(E5440); 3.16(X5460);3(X5450) 1.0 Ghz US-T1

1/1.2/1.4 Ghz US-T1

1.2/1.4 Ghz US-T2

1.2/1.4 Ghz US-T2 1.2/1.4 Ghz US-T2

1.2/1.4 Ghz US-T2

Int. Disks 1x80/160GB SATA or 2x73/146GB SASInt. Drive

PCI-Ex8; 2 PCI-Ex4/XAUI

2 PCI-Ex8; 2 PCI-Ex4; 2 PCI-Ex4/XAUI

1 PCI-Ex8; 2 PCI-Ex4/XAUI

2 PCI-Ex8; 2 PCI-Ex4; 2 PCI-Ex4/XAUI

Onboard Eth 4 GigE 4 GigE 4 GigE; #9 4 GigE; #9 4 GigE 4 GigE; #10

Note 1: Ultra20 M2 supports ATI Rage XL, NVIDIA Quadro FX1400 or NVS 280 Graphics Accelerator; PCI-Ex16 reserved for graphics accelNote 2: 2 PCI-Ex16 for graphics cards; No built-in VGA; USB 2.0 ports; 2 Ge Ports; Integrated RAID 0,1 for Windows XP Professional 32/64 bit Intel Xeon: X model=1.3Ghz FSB, 120W CPU, quad-core; L model= 1.06GHz FSB, 50W CPU, quad-core; E5345 model=1.2Ghz FSB,

80W CPU, quad-core; E5320 model=1.06Ghz FSB, 80W CPU, quad-core; E5160=dual-core (80W CPU); 5260=dual-core; 80W CPU, L2:6MB; L5335=quad-core, 50W CPU, 2x4MB L2; E5410=quad-core, 1.6GHz FSU, 80W, 2x6MB L2; E5440=quad-core, 1.6GHz FSU, 80W CPU, 2x6MB L2; X5460=quad-core, 1.6GHz FSB, 120W CPU, 2x6MB L2; X5450=quad-core, 1.3GHz FSB, 80WCPU

Note 3: If using SAS HDDs, must add a PCI-E SAS HBA

Note 5: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each otherNote 6: SAS=73/146GB 10K; SATA=80/200GB 5400 RPM are 2.5” HDD. Raid 0 or 1 if 2 HDDs are installed.Note 7: internal 300GB 15K SAS (3.5” HDD); Must use w/4-port SAS PCI-E HBA for X2100M2, X2200M2 &Ultra 20 M2. Use 8-port SAS PCI-E for Ultra 40 M2. X2200 M2 needs special cabling x5295A-Z

***: Sun Fire x64 servers support Solaris 10 x86 (32/64-bit)/ RHEL 3 up5+ (32-bit) & 4 up1(64-bit)/SuSe 9(64-bit) /MS 2003/2008 (32/64-bit)/ Vmware ESX (only X4150, X4450, X4100/M2, X4200/M2, X4600/M2)

Note 8: If using SAS HDDs, need to order REM card

Sun Hardware @Glance

Page 2: 4PCI-Ex8;PCI-Ex4;PCI-Ex16 - IASias.ch/docs/SunProductGuide_2008.pdfApril 2008 Unofficial Sun Product Guide - Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra

April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 2

SPARC Enterprise Servers Sun Fire Enterprise ServersM4000 M5000 M8000 M9000-32 M9000-64 V490 V890 E2900 E4900 E6900 E20K E25K

Max. Sockets 4 (dual-core) 8 (dual-core) 16 (dual-core) 32 (dual-core) 64 (dual-core) 4 (2 cores) 8 (2 cores) 12 (2 cores) 12 (2 cores) 24 (2 cores) 36 (2 cores) 72 (2 cores)

Clock Speed 1.35 US-IV; 1.5/1.8/2.1 US-IV+*Cache 5 MB 5 MB 5/6 MB 5/6 MB 5/6 MB 8 MB/core 8 MB/core 16 MB 16 MB 16 MB 16 MB 16 MB

Memory 128 GB 256 GB 512 GB 1024 GB 2048 GB 64 GB 128 GB 192 GB 192 GB 384 GB 576 GB 1152 GBPCI I/O Slots 2 x 73GB 4x 73GB 16 x 73/146GB 32 x 73/146GB 128 PCI-E 6 (2 @66) 9 (2 @66) 6 (1 @66) 16 (12 @66) 32 (24 @66) 36 (27 @66) 72 (54 @66)

Internal Storage SAS 10KRPM SAS 10KRPM SAS 10KRPM SAS 10KRPM 64x73/146GB SAS 2 x 146GB FCAL 12x146GB FCAL 2 x 146GB SCSI n/a n/a n/a n/aPower Cords 4 PCI-E; 1 PCI-X 8 PCI-E; 2 PCI-X 32 PCI-E 64 PCI-E 2 3 4 2-3 2-4 6 12Rack Units n/a n/a n/a n/a n/a 5U 17U 12U 17.5U n/a n/a n/a

Notes 6U (2 domains) 10U (4 domains) (16 domains) (24 domains) (24 domains) 2 domains 4 domains 9 domains 18 domainsCategory F F G G G H (# 23) H (#23) H (note #23) A A A A

Netra SPARC Servers Netra CMT Netra X64 Netra BladesN210 N240 N440 N1290 T2000 T5220 X4200 M2 CT900 (DC) CP3010 CP3020 CP3220 CP3060 CP3260

Max. Sockets 2 2 4 12 1 (4/6/8 cores) 1 (4/8 cores) 2xAMD (2 cores) 2 1 (4/6/8 cores) 1 (6/8 cores)

Clock Speed 1.5 USIV+ 1/1.2Ghz US-T1 2.2 (2214HE) 2.2(148), 1.8(165+) 2.2 (248)Cache 1 MB 1 MB 1 MB L2=2MB; L3=32MB 3 MB 4 MB 1 MB /core 1 MB 1 MB 1 MB 3 MB 3 MB

Memory 8 GB 8 GB 32 GB 192 GB 32 GB 64 GB FB 32 GB DDR2-667 8 GB 8 GB 32 GB 16 GB 16 GB2x73GB 2 x 73GB 4 x 73 GB 2-4x 73/146GB 2-4x146GB 2 x 146 GB 1 x 40 GB 2 x 73GB 2 x 146 GB 1 x80 GB 2 x 146 GB

SAS (15K) U3-SCSI (15K) SCSI-320 (15K) U320 SCSI SAS (note#25) 10K (R0,1) 10KSAS (R0,1) SAS SAS SATA SAS

PCI I/O Slots 1 @33/66 3 (2 @33) 6 (3@ 33/66) 6 (4 @66) 1 PCI-E/3 PCI-X 3 PCI-X; 1 PCI-Ex8 2 PMC 2 PMC 2 AMC PCI-Ex8 1 ARTM4 10/100/1000 - -

Rack Units 1U 2U 5U 12U 2U 2U 2UNotes AC/DC AC/DC AC/DC AC/DC AC/DC DC AC/DC (#21) 4 SAS interfaces HDD uses 1 RTM 1 AMC/PICMG HDD uses 1 ARTM

Category H H H F (note #20) F F F H H F F F

Netra Blades Sun Fire X64 Servers Graphics Adapter Cards for SPARC Workstations Graphics Adapter Cards for X64CT410 CT810 X4100 X4200 XVR-100 XVR-200 XVR-300 x8 XVR-300 XVR-2500 NVIDIA FX370

Max. Sockets CP2140/CP2500 CP2140/CP2500 2xAMD (1-2cores) 2xAMD (1-2cores) Bus Type PCI PCI-E x1 PCI-E x16 PCI-E x16 PCI-E PCI-E x16 PCI-E x16 PCI-E x16

Clock Speed 64 MB 32 MB 128 MB 128 MB 256 MB 256 MB 256 MB Cache 4 MB 4 MB 1 MB /core 1 MB /core Texture n/a n/a n/a n/a 256 MB n/a n/a n/a

Memory 4 GB/2GB 4 GB/2GB 32 GB 32 GB Max Resolution 1920 x 1200 2048 x 1536 1920x1200 1920x1200 2048 x 1536 3840 x 2400 2048 x 1536 2560 x 16002 full/3diskless 2x36/73/146 GB 4x36/73/146GB Dual-Head yes yes yes yes yes yes yes yes

1x36GB SCSI 2x36/73GB SCSI 10KSAS (R0,1) 10KSAS (R0,1) Graphic Ports 2DVI-I, 1 HD15 2 DVI-I 2 DVI-I 2 DVI-I 2 DVI-IPCI I/O Slots 2 PCI-X 5 PCI-X Category E E (LOD 5/08) E E H E E (#22) E (#22)

2 x 10/100 2 x 10/100 4 x 10/100/1000Rack Units 12 RU 12 RU 1U 2U Graphics Adapter Cards for X64 Workstations

Notes CT1600:(2)ct810 or (4)ct410Category H (LOD 8/19/08) E (LOD 5/08; #21) E (LOD 5/08)

Bus Type PCI-E x16 PCI-E x16 PCI-E x16 PCI-E x16 PCI-E x16 PCI-E x16 PCI-E x16 PCI-E x16256 MB 256 MB 256 MB 512 MB 256 MB 512 MB 1 GB 1.5 GB

Texture n/a n/a n/a n/a n/a n/a n/a n/a

Max Resolution 3840 x 2400 3840 x 2400 3840 x 2400 3840 x 2400 3840 x 2400 3840 x 2400 3840 x 2400 3840 x 2400

Dual-Head yes yes yes yes yes yes yes yes

Graphic Ports 2 DVI-I, HD15 2 DVI-I 2 DVI-I, HD15 2 DVI-I /1 stereo 2 DVI-I /1 stereo 2 DVI-I /1 stereo 2 DVI-I /1 Stereo 2 DVI-I /1 stereo

Note 24: If using on-board 10GbE port,must order XAUI card and lose a I/O slot per card Category E (#22) E (#22) E (#22) E (#22) E (#22) E (#22) E (#22) E (#22)

2.15 GHz SPARC64 VI

2.15 GHz SPARC64 VI

2.28/2.4GHz SPARC64 VI

2.28/2.4GHz SPARC64 VI

2.28/2.4GHz SPARC64 VI 1.2/1.35 Ghz US-IV; 1.5/1.8/1.98 US-IV+*

1-Ph / 3-Ph

Dual GigE 1 GigE; 1 10/100 Dual GigE

12 ATCA processor blade slots, 2 switch blade

slots; PICMG 3.0 & 3.1 compliant; NEBS Level 3

certified in a 12 RU . Supports both SPARC &

Opteron processor blades

1xAMD HE (1-2cores) 1xAMD (2cores)

1.34 Ghz US-IIIi 1.5 Ghz US-IIIi 1.6 Ghz US-IIIi 1.2 Ghz US-T2 1.1 Ghz US-IIIi+ 1 Ghz US-T1 1.2 Ghz US-T2

Int. Disks 2x146/300GB @15K

Int. Drive PMC (use I/O slot)

2 PCI-X; PCI-Ex16; PCI-Ex8; 2 PCI-Ex4/XAUI

Onboard Eth Dual GigE 2 GigE 4 GigE 4 GigE; #24 4 GigE Up to 7 GigE Up to 7 GigE2 GigE 2 GigE 2 GigE 2 GigE 2 GigE

nVIDIA NVS285 nVIDIA NVS290

650Mhz US-IIi/1GHz US-IIIi+2.6(x52-) / 2.8(x54-) / 3.0 (x56-) / 2.0 (x70) / 2.2 (x75) / 2.4 (x80[SE]) / 2.6(x85) / 2.8(x90) Frame Buffer Mem

64MB DDR / 128GB DDR2

Int. Disks No floppy dr

Int. Drive1 DVI-I, 1 HD15, S-

Video1 DSM-59 for dual

DVI-I1 DSM-59 for dual

DVI-I5 cPCI 6 cPCI

Onboard Eth

nVIDIA FX560 nVIDIA FX570 nVIDIA FX1500 nVIDIA FX1700 nVIDIA FX3500 nVIDIA FX3700 nVIDIA FX4600 nVIDIA FX5600

Note 20: New PCI+I/O Assembly brd

Note 21: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each other Frame Buffer Mem

Note 22: NVidia graphics brds need ext power (like a disk drive), since not all Sun systems offer the power connector

Note 23: 2.1 Ghz CPU modules will not fit in the current V490/V890 chassis. Must be order with new chassis with appropriate power supplies.

Note 25: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each other. Disk drives controlled by an LSI SAS1064 controller. Raid 0 & 1 Support with via on-board SAS controller with the installation of patches >=119850-13 and 122165-01.

Sun Hardware @Glance

Page 3: 4PCI-Ex8;PCI-Ex4;PCI-Ex16 - IASias.ch/docs/SunProductGuide_2008.pdfApril 2008 Unofficial Sun Product Guide - Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra

April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 3

Network Attached Storage (NAS)D240 3120 3320 3510 FC 2510 2530 2540 5220 NAS 5320 NAS 5320 NAS Cluster 5320 NAS Gate

# of Drives 4 4 12 12 12 12 12 # of Drives 16 16 16 n/a

Type of Drives 73/146 GB 73/146/300GB LVD 73/146/300 GB 36/73/146/300 GB 73/146/300 GB SAS ; 500/750GB/1TB SATA-II Type of Drives 250/500 GB SATA 300GB FC /500/750 GB SATA-IIDrive Speed 10K/15K SCSI 10K/15K SCSI 10K/15K SCSI 10K/15K FC 73/146/300 @15K Drive Speed 7200 RPM 10K/15K FC-AL & 7.2K SATA-II -

Capacity 584 GB 1.2 TB 10.8 TB 32.4 TB 18 TB 18 TB 18 TB Capacity 24 TB 67TB FC/336TB SATA 65 TBRAID SW JBOD-SW HW 0,1,3,5 HW 0,1,3,5,10 HW 0,1,3,5, 10 RAID HW5 (6+1&7+1) HW5 HW5 HW 5

Host Connect SE-SCSI SCSI 2x LVD SCSI 2 GB FC-AL (6) 3GB SAS (4) 4GB FC Cache 2 GB 2 dual-port 2Gbs FC 2 dual-port 2Gbs FC 2 dual-port 2Gbs FC

Rack Units 2 RU 1 RU 2 RU 2 RU 2 RU 2 RU 2 RU Power Cords head=1; tray=2 head=2; tray=2 head=4; tray=2 2Cache n/a n/a 1GB/controller Rack Unit head=1U; tray=3U head=2u; tray=3u head=4u; tray=3u 2U

Power Cords 2 2 2 2 2 2 2 NotesNotes DVD/DDS optional NEBS-3 (AC/DC) NEBS-3; #31 NEBS-3; #32 NEBS-3 : up to 16 partitions

Category P P P F F F Category G (Note #33/#38) M (#38) M M

ST5800 6140 CSM200 (CSM2) 6540 9985V 9990V VTL-V VTL + 1140 VTL + 2540 VTL + 3540

# of Drives 16 16 Max. Capacity 112 TB 72 TB 330 TB Max. Capacity 24 TB 56 TB 224 TB 224 TB

Type of Drives Max. Spindles 224 240 16384 2 16 64 128Drive Speed FC @15K; SATA-II @7.2K Active Ports 8 4Gb FC 48 192 5 128 512 1024

Capacity 8 TB/tray (56TB) Cache 4/8/16 GB 64 GB 256 GB - 2048 4096 8192

RAID HW 0,1,3,5,1+0 - Disk Drives 73/146/300 GB FC ports Tot. 4 2Gb FC 6 (2 per hosts) 28 (8 per hosts) 56 (16 per hosts)Host Connect Disk Types 500/750 @7.2K SATA 73/146 @15K, 300 @10K active/active active/active 1 (opt. cold spare) 2 (active/active)

Rack Units 3 RU 3 RU RAID HW:0,1,3,5,1+0 HW-1,10,5,6 HW-1,10,5,6 Host Connect. 2 8 16 32Cache Max. Cabinets 1 5 -Notes Note #34 & cords=2 Notes Two 30A/50A power cords/cabinet Notes SL500, L700e, M1400, SL8500 : all tape drives (#37)

Category Category M P P (note #36) Category M M M M

C2 SL 24 C4 SL48 SL500 9740 L700e L1400M SL3000 SL8500

Support Media# of Drives 1 1 or 2 2 2 or 4 1-18 12:9840, 20:DLT,LTO2,LTO3 12-40 56 64

Max. Cartridges 16 24 32 SDLT/38 LTO 48 395 326 or 494 700 (690 data + 10 cleaning) 800-1344 5821 6500

Cart Native Cap

Dr. Native Thru

Tot. Native Cap.6.4 TB LTO3 9.6 TB LTO3 15.2 TB LTO3 19.2 TB LTO3 79 TB LTO2

30 TB 406TB SDLT600Interface LVD SCSI LVD SCSI or FC LVD SCSI & FC FC-AL; LVD SCSI FC-AL, SCSI SCCI-2;serial LVD, FC-AL SCSI3;FC-AL FC-AL LVD, FC-AL

Notes 2RU 2RU 4RU 4RU

Category P M P M M C M M M M

Note 32: 300GB drives require V3.0.1 software; Six 2GB FC per controller tray (4 for host and 2 for expansion unit); Up to 8 expansion units daisy-chained of SE3510Note 33: The 5220 RAID Controller Unit (CU) and the 5220 Expansion Unit (EU) are the only supported storage for the 5220 NAS appliance.

Note 37: VTL +: VTL server is a Sun Fire V40z. Professional Services Required for implementation.

StorageTek Workgroup Systems

Uses ST6920/ 99xx/ 6130/FLXxxx

(4) iSCSI GigE

512 MB/contr 512 MB/cont 512 MB/contr 512 MB/contr

(1)2.2GHz AMD, 2GB RAM, 4GigE, 1 PCI-X, NFS,CIFS, iSCSI

(1)2.6GHz AMD, 4GB RAM, 2PCI-X,4GigE,

NFS,CIFS, iSCSI

2 Heads: (1) 2.6GHz AMD, 4GB RAM,2PCI-X, 4GigE NFS,CIFS, iSCSI

1x2.6GHz AMD, 4GB RAM, 4GigE NFS,CIFS, iSCSI, (2)

dual FC HBA

P (non-RoHS)

StorageTek Disk Systems StorageTek Mid-Range/DataCenter Storage Systems Sun StorageTek Virtual Tape Library Systems

An open, fixed-content system

optimized to store large amounts of digital content

allowing customer to define metadata indexing & search capabilities. Sun

Fire X2100 derivative design with capacity from 8 nodes to 32

nodes.

73/146/300/400GB FC /500/750 GB SATA

73/146/300/400GB FC /500/750 GB SATA Virt Tape Lib.

Virt Tape Dr.12 TB/tray w/SATA Virt Tape Cart.

73/146/300/400/500/750 GB

73/146/300 GB (1112 HDD + 40 spares)

4 Gb FC 4 Gb FC Emul. Servers

4GB w/8 hst | 2GB w/4 hst Expansion unit only for 6130,6140,6540, FLXxxx

16 HDD/contr in 3U Thruput 400 MB/s 700 MB/s 1400 MB/s4Gb/s FC disk

M (NEBS-3 Cert) M (NEBS-3 Cert)

StorageTek Tape Library

LVD SCSI: DLT600, LTO3, LTO2V, DLT-S4

FC: LTO3/4; SCSI: LTO4, LTO3, LTO2

HH

FC: SDLT600, LTO3 (4Gb FC), DLT-S4;

LVD SCSI: SDLT600, LTO2/3, DLT-S4

FC: LTO3/4; SCSI: LTO4, LTO3, LTO2 HH

FC: LTO2/3/4, SDLT600, DLT-S4;

LVD SCSI: LTO2/3/4, SDLT320/600 , DLT-

S4

FC / FICON / ESCON: T9840C, T9940B, T10000,

LTO4

FC: 9840C, 9940B, T10000, SDLT600, LTO2/3/4, DLT-S4; FICON: 9840C, 9940B, T10000; ESCON: 9840C, 9940B; LVD SCSI:

SDLT320/600, LTO2/3/4; HVD SCSI: SDLT320

FC: 9840C, T10K, LTO3/4; FICON: 9840C, 9840D, T10K, ESCON:

9840C, 9840D

FC: 9840C, 9940B, T10K, SDLT600,

LTO2/3/4, DLT-S4; FICON: 9840C, 9940B, T10K, ESCON: 9840C,

9940BUpto 10

SDLT320:160GB SDLT600:350GB T9840B-FC:20GB T9840C-FC: 40GB T9940B-FC:200GB LTO2-SCSI:200GB LTO2-FC:200GB LTO2-HH: 200GB LTO3:250GB 2Gb-T10000:500GB DLT-S4:800GB LTO4:800GB

SDLT320:16MB/s SDLT600:36MB/s T9840B-FC:19MB/s T9840C-FC:30MB/s T9940B-FC:30MB/s LTO-HH: 24MB/s LTO2-SCSI:30MB/s LTO2-FC:30MB/s LTO3:80MB/s 2Gb-T10000:120MB/s DLT-S4:60MB/s LTO4:120MB/s

108TB SDLT320, 135TB LTO2

1.5PB(T10K); 2.4PB(LTO4); 225TB(9840D)

58TB (9840c), 1300TB (9840B/LTO2)

Req. ACSLS S/W

Note 31: 3320 JBOD model CANNOT be upgraded to 3320 w/controllers. Once a 3320 JBOD, always a 3320 JBOD. 3510/3511 JBOD CAN be upgraded with 1 or 2 controllers

Note 34: Mixing FC & SATA drives are supported (73/146 GB @15K RPM FC; 146/300 GB @10K RPM FC; 500 GB @7.2K RPM SATA). Max Cap=2GB controller tray + 3 exp tray OR 4 GB controller tray + 6 exp tray.Note 36: Able to configure with NAS Blade (Xeon 2.8GHz, 4GB memory, 4 GigE, running Debian GNU/Linux OS ver 2.24.17 with antivirus support for SAVSE). upto 6 FE Directors and upto 4 BE Directors, and upto 256 HDD per ACP

Note 38: 5xx0 JBOD model CANNOT be upgraded to 5xx0 w/controllers. Once a 5xx0 JBOD, always a 5xx0 JBOD.

Sun Hardware @Glance

Page 4: 4PCI-Ex8;PCI-Ex4;PCI-Ex16 - IASias.ch/docs/SunProductGuide_2008.pdfApril 2008 Unofficial Sun Product Guide - Page 1 Thin Clients Desktops / Workstations Sun Fire X64 Servers Ultra

April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 4

D-Ser ies: Direct -a t tached, s ingle tape dr ivesDAT 72 LTO2(V) SDLT600 DLT S4 LTO3 LTO 4 T9840C T9840D T10000A

Support Media DAT 72 LTO2 SDLT600 DLT-S4 LTO3 LTO 4 9840C 9940D T10000 Max. Capacity 11.62 TB 23.2 TB# of Drives 2 2 2 2 2 2 2 2 1 Max. Spindles 8192 2048

Max. Cartridges 1 1 1 1 1 1 1 1 1 Active Ports 32 16

Cart Native Cap. 36 GB 200 GB 300 GB 800 GB 400 GB 800 GB 40 GB 73 GB Cache 96 GB 96 GB

Disk Drives 73 GB FC-AL 73/146 GB FC-AL

Total Native Cap. 36 GB 200GB 300GB 800 GB 400GB 800 GB - Disk Types 15K RPM 15K RPMInterface LVD,SE-SCSI LVD,SE-SCSI LVD,SE-SCSI LVD,SE-SCSI LVD,SE-SCSI FC2,FICON,FC4 FC2, ESCON/FICON FC2,FICON,FC4 RAID HW-1+0,5 HW-1+0,5

Notes desktop;1RU Desktop Desktop;2RU desktop;2RU Desktop,2RU - n/a n/a Desktop,2RU Max. Cabinets 32 ESCON/16 FC 16 FICONCategory A A A H H M M M Category

Network Switches: BrocadeSilkworm 200E 7500 Silkworm 5000 Silkworm 4900 M6140 Silkworm 48000 M i10K DCX

No. of Ports 16 16 FC & 2 GE 32 64 140 384 256 384 (768) 16 (64) 16 (64) 16 (256) 32 (256)Throughput

Connect Type Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) Uses SFP (LC) SFP (LC) SFP (LC) SFP (LC) SFP (LC)

Modes Operation Fabric Fabric Fabric Fabric Fabric Fabric FabricNo Yes Yes Yes Yes Yes Yes Yes No Yes Yes Yes

Rack Units 1U 1U 1U 2U 12U 14U 14 U 14 U 1U 1U 4U (8U) 4U (8U)Notes Note #15 no SFP or cables Note #16 Note #16 Comes with SFP Comes with SFP Comes with SFP Comes with SFP

Category P M / P P P P P P P H H M M

IB Switch 9p MDS 9124 MDS 9134 MDS 9140 MDS 9216i MDS 9216a MDS 222i MDS 9509 MDS 9513 VSM4e VSM4 VSM5

No. of Ports 9 24 32 (64) 40 14 (2FC/GE) 16 18 336 (1008) 528 (1584) Max. Capacity 1.25 TB 14.9 TB 28 TB

Throughput 256 256 256Connect Type Uses SFP (LC) Channels 8FICON or 16ESCON 16 FICON/32ESCON 16 FICON

Modes Operation Copper Fabric; Public Loop 8 GB 32 GB 32 GBRedundant Power Yes Yes Yes Yes Yes Yes Yes Yes Yes 32 GB 128 GB 73 GB FC-AL

Rack Units 1U 1U 1U 1U 3 RU 3 RU 3 RU 14 RU Disk Types 15K RPM 15K RPM 15K RPMNotes Comes with SFP Comes with SFP Non-viol Storage 2048 MB 2048 MB 2048 MB

Category H M M M M M M M M 1024 MB 1024 MB 1024 MBNotes

Note 10: STK C4 comes in native SCSI or native Fibre. If you order the native SCSI and wants to go to FC, order the FC1202 SCSI to FC bridge (SG-XFCCARD2-C-Z) and can only use the LVS SCSI media* L500 with SDLT320 is for LTO only version & SDLT600 is for mix media version

StorageTek Shared Virtual Array Crypto Key Station FlexLine V2X2 FlexLine V2X4F

Sun StorageTek Crypto Key

Management Station consists of

a Sun Ultra 20 running Solaris 10 with a Sun Crypto Accelerator 6000 card for random

number generator. FIPS Level 2 AES 256

CCM mode

120/500 GB (24 passes)

Dr Nat Thruput 3 MB/s 30 MB/s 36 MB/s 60 MB/s 80 MB/s 120 MB/s30 MB/s (unc) 70

MB/s (com) 30 MB/s120 MB/s (unc); 360

MB/s (com)

Native, 3490E, 35903592 (MVS); 3490

(VSM)U320 SCSI, 4-Gb FC

A (RoHS) C (Non-RoHS) C (Non-RoHS)

Network Switches: QlogicSANbox 5600 SANbox 5602 SANbox 9100 SANbox 9200

4 Gb/s 4 Gb/s 1/2/4 Gb/s 4 Gb/s 2 Gb/s 8 Gb/s 10 Gb/s 8 Gb/s 4 Gb/s 4 Gb/s 1/2/4/10 Gb/s 1/2/4/10 Gb/s

Broadcast; SMS; NSZ

Broadcast; SMS; NSZ

Broadcast; SMS; NSZ

Fabric; Public Loop

Fabric; Public Loop

Redun Power

Ini f iband Switches Network Switches: Cisco Sun StorageTek Virtual Storage Manager Systems

10Gb/s (4x) or 30Gb/s(12x) 4 Gb/s 4/10 Gb/s 2 Gb/s 2 Gb/s 2 Gb/s 1/2/4/10 Gb/s 1/2/4/10 Gb/s 1/2/4/10 Gb/s Virt. Tape Drives

Cisco SFPs only (LC) Cisco SFPs only (LC)Fabric; Public

LoopFabric; Public

LoopFabric; Public

LoopFabric; Public

LoopFabric; Public

LoopFabric; Public

LoopFabric; Public

Loop Phys. CacheEff Cache (4:1)

14 RuNeed to order SFPs and includes Fabric Manager software

Eff Non-Viol Sto.HSC 6/VTCS6,z/OS 1.1+

Sun Hardware @Glance