USB ports 6 USB, 2FW 6 USB, 2FW 6 USB, 2FW 6 USB,2FW 8 USB,2FW 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000 4 x 10/100/1000
PCI I/O Slots Rack Units 1U 1U 1U 2U 1U 4UNotes No built-in graphics On-board 2D graphics R0,1 for W-XP only Notes on-board 2D VGA; SP; #7
H Category F H F E E Category E E E (note#5) E E E
Sun Fi re X64 Servers *** Sun Fi re X4950 Sun Blade SystemsX4150 X4450 X4600 M2 X4500 Sun Blade 8000 Sun Blade 8000 P X8420 X8440 X8450 Sun Blade 6048 Sun Blade 6000
Max. Sockets 2 x Intel (2-4 cores) 4 x Intel (2-4 cores) 8xAMD (2cores) 2-4xIntel (2-4cores)
Memory 32 GB DDR2 64 GB FB 64 GB DDR2 64 GB FB-DIMM 32 GB 64 GB 64 GB FB 64 GB FB 64 GB FB 128 GB FB4x73/146/80 GB 4 x 73/146 GB 4x73/146/80/200 GB 4x73/146/80/200 GB 4x 73/146GB 4 x 73/146 GB 8 x 73/146GB 4 x 73/146GB 8/16 x 73/146GBSAS; SATA (80) SAS 10K (R0,1) SAS; SATA (80/200) SAS; SATA (80/200) SAS 10K (#4) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1) SAS 10K (R0,1)
PCI I/O Slots 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 2 PCI-Ex8 EM 1 PCI-E 3 PCI-E; 2 PCI-X2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM 2 PCI-Ex8 NEM
Rack Units Note #6 Note #6 Note #6 Note #8 1U 2U 1U 2U 1U 2UCategory F F F F F (Solaris 10 1/06) F (Solaris 10 8/07) F (Solaris 10 8/07)
** Each pair of cores integrated with up to 4 MB of L2 Intel Advanced Smart Cache
Note 4: One PCI-X slot is occupied by a SAS disk controller card installed by factory
Note 9: If using on-board 10GbE port,must order XAUI card and lose an I/O slot per cardNote 10: HDD capacity is set by the type of backplane installed and must be selected at the time of order (via PTO/ATO backplane opt). It cannot be changed in the field.
SunRay 2(FS) / 270
Sun Ray provides instant, constant, simple and secure
Note 1: Ultra20 M2 supports ATI Rage XL, NVIDIA Quadro FX1400 or NVS 280 Graphics Accelerator; PCI-Ex16 reserved for graphics accelNote 2: 2 PCI-Ex16 for graphics cards; No built-in VGA; USB 2.0 ports; 2 Ge Ports; Integrated RAID 0,1 for Windows XP Professional 32/64 bit Intel Xeon: X model=1.3Ghz FSB, 120W CPU, quad-core; L model= 1.06GHz FSB, 50W CPU, quad-core; E5345 model=1.2Ghz FSB,
Note 3: If using SAS HDDs, must add a PCI-E SAS HBA
Note 5: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each otherNote 6: SAS=73/146GB 10K; SATA=80/200GB 5400 RPM are 2.5” HDD. Raid 0 or 1 if 2 HDDs are installed.Note 7: internal 300GB 15K SAS (3.5” HDD); Must use w/4-port SAS PCI-E HBA for X2100M2, X2200M2 &Ultra 20 M2. Use 8-port SAS PCI-E for Ultra 40 M2. X2200 M2 needs special cabling x5295A-Z
***: Sun Fire x64 servers support Solaris 10 x86 (32/64-bit)/ RHEL 3 up5+ (32-bit) & 4 up1(64-bit)/SuSe 9(64-bit) /MS 2003/2008 (32/64-bit)/ Vmware ESX (only X4150, X4450, X4100/M2, X4200/M2, X4600/M2)
Note 8: If using SAS HDDs, need to order REM card
Sun Hardware @Glance
April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 2
SPARC Enterprise Servers Sun Fire Enterprise ServersM4000 M5000 M8000 M9000-32 M9000-64 V490 V890 E2900 E4900 E6900 E20K E25K
Internal Storage SAS 10KRPM SAS 10KRPM SAS 10KRPM SAS 10KRPM 64x73/146GB SAS 2 x 146GB FCAL 12x146GB FCAL 2 x 146GB SCSI n/a n/a n/a n/aPower Cords 4 PCI-E; 1 PCI-X 8 PCI-E; 2 PCI-X 32 PCI-E 64 PCI-E 2 3 4 2-3 2-4 6 12Rack Units n/a n/a n/a n/a n/a 5U 17U 12U 17.5U n/a n/a n/a
Notes 6U (2 domains) 10U (4 domains) (16 domains) (24 domains) (24 domains) 2 domains 4 domains 9 domains 18 domainsCategory F F G G G H (# 23) H (#23) H (note #23) A A A A
Memory 4 GB/2GB 4 GB/2GB 32 GB 32 GB Max Resolution 1920 x 1200 2048 x 1536 1920x1200 1920x1200 2048 x 1536 3840 x 2400 2048 x 1536 2560 x 16002 full/3diskless 2x36/73/146 GB 4x36/73/146GB Dual-Head yes yes yes yes yes yes yes yes
1x36GB SCSI 2x36/73GB SCSI 10KSAS (R0,1) 10KSAS (R0,1) Graphic Ports 2DVI-I, 1 HD15 2 DVI-I 2 DVI-I 2 DVI-I 2 DVI-IPCI I/O Slots 2 PCI-X 5 PCI-X Category E E (LOD 5/08) E E H E E (#22) E (#22)
2 x 10/100 2 x 10/100 4 x 10/100/1000Rack Units 12 RU 12 RU 1U 2U Graphics Adapter Cards for X64 Workstations
Notes CT1600:(2)ct810 or (4)ct410Category H (LOD 8/19/08) E (LOD 5/08; #21) E (LOD 5/08)
Note 24: If using on-board 10GbE port,must order XAUI card and lose a I/O slot per card Category E (#22) E (#22) E (#22) E (#22) E (#22) E (#22) E (#22) E (#22)
2.15 GHz SPARC64 VI
2.15 GHz SPARC64 VI
2.28/2.4GHz SPARC64 VI
2.28/2.4GHz SPARC64 VI
2.28/2.4GHz SPARC64 VI 1.2/1.35 Ghz US-IV; 1.5/1.8/1.98 US-IV+*
Note 21: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each other Frame Buffer Mem
Note 22: NVidia graphics brds need ext power (like a disk drive), since not all Sun systems offer the power connector
Note 23: 2.1 Ghz CPU modules will not fit in the current V490/V890 chassis. Must be order with new chassis with appropriate power supplies.
Note 25: Two diff chassis: 2 HDD w/DVD or 4HDD and can't be converted to each other. Disk drives controlled by an LSI SAS1064 controller. Raid 0 & 1 Support with via on-board SAS controller with the installation of patches >=119850-13 and 122165-01.
Sun Hardware @Glance
April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 3
Network Attached Storage (NAS)D240 3120 3320 3510 FC 2510 2530 2540 5220 NAS 5320 NAS 5320 NAS Cluster 5320 NAS Gate
# of Drives 4 4 12 12 12 12 12 # of Drives 16 16 16 n/a
Type of Drives 73/146 GB 73/146/300GB LVD 73/146/300 GB 36/73/146/300 GB 73/146/300 GB SAS ; 500/750GB/1TB SATA-II Type of Drives 250/500 GB SATA 300GB FC /500/750 GB SATA-IIDrive Speed 10K/15K SCSI 10K/15K SCSI 10K/15K SCSI 10K/15K FC 73/146/300 @15K Drive Speed 7200 RPM 10K/15K FC-AL & 7.2K SATA-II -
30 TB 406TB SDLT600Interface LVD SCSI LVD SCSI or FC LVD SCSI & FC FC-AL; LVD SCSI FC-AL, SCSI SCCI-2;serial LVD, FC-AL SCSI3;FC-AL FC-AL LVD, FC-AL
Notes 2RU 2RU 4RU 4RU
Category P M P M M C M M M M
Note 32: 300GB drives require V3.0.1 software; Six 2GB FC per controller tray (4 for host and 2 for expansion unit); Up to 8 expansion units daisy-chained of SE3510Note 33: The 5220 RAID Controller Unit (CU) and the 5220 Expansion Unit (EU) are the only supported storage for the 5220 NAS appliance.
Note 37: VTL +: VTL server is a Sun Fire V40z. Professional Services Required for implementation.
Note 31: 3320 JBOD model CANNOT be upgraded to 3320 w/controllers. Once a 3320 JBOD, always a 3320 JBOD. 3510/3511 JBOD CAN be upgraded with 1 or 2 controllers
Note 34: Mixing FC & SATA drives are supported (73/146 GB @15K RPM FC; 146/300 GB @10K RPM FC; 500 GB @7.2K RPM SATA). Max Cap=2GB controller tray + 3 exp tray OR 4 GB controller tray + 6 exp tray.Note 36: Able to configure with NAS Blade (Xeon 2.8GHz, 4GB memory, 4 GigE, running Debian GNU/Linux OS ver 2.24.17 with antivirus support for SAVSE). upto 6 FE Directors and upto 4 BE Directors, and upto 256 HDD per ACP
Note 38: 5xx0 JBOD model CANNOT be upgraded to 5xx0 w/controllers. Once a 5xx0 JBOD, always a 5xx0 JBOD.
Sun Hardware @Glance
April 2008 Unofficial Sun Product Guide - http://sungeeks.central Page 4
D-Ser ies: Direct -a t tached, s ingle tape dr ivesDAT 72 LTO2(V) SDLT600 DLT S4 LTO3 LTO 4 T9840C T9840D T10000A
Support Media DAT 72 LTO2 SDLT600 DLT-S4 LTO3 LTO 4 9840C 9940D T10000 Max. Capacity 11.62 TB 23.2 TB# of Drives 2 2 2 2 2 2 2 2 1 Max. Spindles 8192 2048
Notes desktop;1RU Desktop Desktop;2RU desktop;2RU Desktop,2RU - n/a n/a Desktop,2RU Max. Cabinets 32 ESCON/16 FC 16 FICONCategory A A A H H M M M Category
Rack Units 1U 1U 1U 2U 12U 14U 14 U 14 U 1U 1U 4U (8U) 4U (8U)Notes Note #15 no SFP or cables Note #16 Note #16 Comes with SFP Comes with SFP Comes with SFP Comes with SFP
Rack Units 1U 1U 1U 1U 3 RU 3 RU 3 RU 14 RU Disk Types 15K RPM 15K RPM 15K RPMNotes Comes with SFP Comes with SFP Non-viol Storage 2048 MB 2048 MB 2048 MB
Category H M M M M M M M M 1024 MB 1024 MB 1024 MBNotes
Note 10: STK C4 comes in native SCSI or native Fibre. If you order the native SCSI and wants to go to FC, order the FC1202 SCSI to FC bridge (SG-XFCCARD2-C-Z) and can only use the LVS SCSI media* L500 with SDLT320 is for LTO only version & SDLT600 is for mix media version