    DeltaSol PoolMounting

    Connection

    Operation

    D e l t a S

    o l

    P o o l

    Manual

    Thank you or buying this product.Please read this manual care ully to get the best per ormance rom this unit.

    en

    4 8 0 0 4 1 1 0

    * 4 8 0 0 4 1

    1 0 *

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    2/20

    Table o contentsSa ety advice .............................................................................................2

    Overview o unctions and technical data..............................................3

    1. Installation ........................................................................................... 41.1 Mounting ......................................................................................................41.2 Electrical connection .................................................................................41.2.1 Overview o electrical connections .......................................................41.2.2 Actuators .....................................................................................................51.2.3 Data communication / bus .......................................................................51.2.4 Sensors .........................................................................................................61.2.5 Mains supply ................................................................................................6

    2. Basic system ........................................................................................72.1 Sensor allocation ........................................................................................72.2 Relay allocation ...........................................................................................7

    3. Operation and unction ..................................................................... 83.1 Buttons or adjustment .............................................................................83.2 Control lamp ...............................................................................................83.3 Menu structure ...........................................................................................93.4 User code ....................................................................................................93.5 Menu overview .........................................................................................10

    4. Commissioning ................................................................................. 11

    5. Functions and options ......................................................................11

    6. Messages ............................................................................................16

    7. Balance values ...................................................................................18

    8. Troubleshooting ................................................................................1810. Accessory ..........................................................................................20

    Imprint ..............................................................................................22

    Sa ety advicePlease pay attention to the ollowingsa ety advice in order to avoid dangerand damage to people and property.

    Appropriate usageThis product is to be used in solarthermal systems in com pliance withthe technical data speci ed in theseinstructions (see p. 3).Improper use excludes all liabilityclaims

    Instructions:Attention should be paid to- valid local regulations

    - the statutory provisions or preven-tion o industrial accidents,

    - the statutory provisions or environ-mental protection,

    - the Health and Sa ety at Work Act1974

    - Part P o the Building Regulations2005

    - BS7671 Requirements or electricalinstallations and relevant sa ety re-gulations o DIN, EN, DVGW, TRGI,

    TRF and VDE.These instructions are exclusivelyaddressed to authorised skilled per-sonnel.- Only quali ied electricians should

    carry out installation and main-tenance work.

    - Initial installation should be carriedout by named quali ed personnel

    Subject to change without no tice.

    Errors excepted

    Declaration o con ormityThe product complies with the relevant direc-tives and is there ore labelled with the CE mark.The Declaration o Con ormity is available uponrequest, please contact the manu acturer.

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 2

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    3/20

    155,0

    2 2 0

    , 0

    2 0 2

    , 0

    12,0

    62,0

    controller for heating a swimmingpool by means o solar absorbersin combination with the optimisedoperation o the lter system

    solar operating hours counter andheat quantity measurement 13 sensor inputs 7 relay outputs function control VBus

    Attention: Electrostaticdischarge can cause damageo electronic components

    Warning: high-voltage com-ponents

    Scope o delivery:

    1 x DeltaSol Pool

    1 x accessory bag2 x screws and dowels8 x strain relie and screws1 x capacitor 4,7 nF

    Technical dataHousing: plastic, PC-ABS and PMMAProtection type: IP 20 / DIN 40 050Ambient temperature: 0 ... 40 C

    Dimensions: 220 x 155 x 62 mmMounting: wall mounting, mountinginto patch panels is possibleDisplay: 4-line LCD text displayOperation: 3 push buttons at the

    rontFunctions: controller or heatinga swimming pool by means o solarabsorbers in combination with the op-timised operation o the lter system.Add-on a terheating o the swimming

    pool depending on the need and on thepower o the solar absorbers.Solar loading:When the absorber temperature is byan adjusted value higher than the pool

    temperature, solar loading starts. I the di erence between fow and pool

    alls below a certain value, or i themaximum temperature is reached, solarloading is stopped.Sensor inputs: 10 sensor inputs orPt1000, 1 x CS10, 1 x IMP and 1 digitalinputRelay output: 7 relay output, 1 o them foatingBus: VBus

    Power supply: 115V~Switching capacity: 2 (1) A (115) V~(standard relay)4 (1) A (115) V~(potential- ree relay)

    Rated impulse voltage: 2,5 kVMode o operation:type 1.b / type 1.y

    Degree o pollution: 2

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    3 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    4/20

    1.1 Mounting

    The unit must only be located in dry interior locations. Itis not suitable or installation in hazardous locations andshould not be placed close to any electromagnetic elds. Thecontroller must additionally be supplied rom a double-poleswitch with contact gap o at least 3 mm. Please pay atten-tion to separate routing o sensor cables and mains cables.

    1. Open the ront cover by pushing it. Unscrew the cross-head screw rom the cover and remove it along with the

    ront cover rom the housing.2. Mark the upper astening point on the wall and drill and

    asten the enclosed wall plug and screw leaving the headprotruding.

    3. Hang the housing rom the upper astening point andmark the lower astening point through the hole in theterminal box (centres 135 mm). Drill and insert the lowerwall plug.

    4. Hang the housing rom the upper astening point andattach with the lower screw.

    5. Carry out connection in accordance with the terminalallocation.

    6. Insert cover and attach with the cross-head screw. Closethe ront cover properly.

    1. Installation WARNING!Always disconnect the controller

    rom power supply be ore openingthe housing!

    1.2 Electrical connection

    VBus

    neutral conductorcommon terminal block

    protective conductorcommon terminal block

    mains terminals

    useT4 A

    sensor terminals load terminals

    sensor - ground - common terminal block

    1.2.1 Overview o electrical connections

    astening

    astening

    display

    push buttons

    use T4Acover

    push-push locking mechanismpush to openpush to close

    screw

    1 3 5 m m

    144 mm

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 4

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    5/20

    electromech.

    relay

    R 7

    - A

    R 7

    - M

    R 7

    - R

    floating relay

    R 3

    R 2

    R 1

    R 6

    R 5

    R 4

    1.2.2 Actuators(pumps, valves, etc.)

    The controller is equipped with 7 relays to which loads(actuators) such as pumps, valves and auxiliary relays canbe connected:

    Relays R1 ... R6 are electromechanical relays with 1normally open contact:R1 ... 6 = normally open R1 ... R6N = neutral conductor N

    (common terminal bloc)PE = protective conductor PE

    (common terminal bloc)

    Relay R7 is a potential- ree (foating) relay with change-over contact:R7-M = center contact R7R7-A = normally open R7R7-R = normally closed R7neutral conductor - common terminal block

    protective conductor - common terminal block

    S 8 C S 1 0

    R 7

    - A

    R 7

    - M

    floating

    Bus

    VBus S 9 S 1

    0

    i m p

    D I n

    1.2.3 Data communication / busThe controller is equipped with the VBus or data trans erwith and energy supply to external modules. The connec tionis carried out at the two terminals marked VBus (eitherpolarity). One or more VBus modules can be connected viathis data bus:

    WMZ calorimeter large display Datalogger

    VBus terminals

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    5 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    6/20

    L Nelectromech.

    relay

    2

    L'

    R 7

    - A

    R 7

    - M

    R 7

    - R

    floating relay

    R 3

    R 2

    R 1

    T4A

    R 6

    R 5

    R 4

    1.2.4 Sensors

    G N D

    S 1 S 2 S 3 S 4 S 5 S 7 S 6 S 8 C S 1 0

    Sensors

    S 9 S 1 0

    i m p

    D I n

    ground-common terminal block

    The controller is equipped with 13 sensor inputs in total.The ground connection or the sensors has to be carriedout via the ground terminal block (GND). Temperature sensors have to be connected to the

    terminals S1 ... S10 and GND (either polarity).

    The irradiation sensor (CS10) is to be connectedto the terminals CS10 and GND with correct polarity.Connect the terminal GND o the sensor to the terminalGND o the controller (ground terminal block), and theterminal CS o the sensor to the terminal CS10 o thecontroller.

    A owmeter can be connected to the terminals Imp andGND (either polarity).

    An external message signal can be connected to the

    digital input Din. When the signal contact closes theinput Din, the message !message ext. is generated.This signal is treated like an error, which means that thecontrol lamp fashes red and the message relay is possiblyenergised.

    1.2.5 Mains supply

    The power supply to the controller must be carried outvia an external power switch (last step!) and the supplyvoltage must be 115 V~ (50 ... 60 Hz). Flexible cables mustbe attached to the housing with the enclosed strain relie and the corresponding screws or be run into the controllerhousing in a cable conduit or trunking.

    protective conductor PE (common terminal block)

    neutral conductor N (common terminal block)

    conductor L

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 6

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    7/20

    2. Basic system

    Relay allocation

    Sensor allocationS1 S2 S3 S4 S5 S6 S7 S8 CS10 S9 S10 Imp Din

    T-absorber T-pool T-fow T-outd. T-return(WMZ) irradiation fow ratereleaselter system

    switch-extra lter runtime

    R1 R2 R3 R4 R5 R6 R7

    lter pump pump (P2)a terheating signal relay operating relayvalve (V1)

    open(solar pump)

    valve (V1)closed

    demanda terheating

    potential- ree

    sensor descriptionT-absorber absorber temperatureT-pool swimming pool temperatureT-fow fow temperatureT-outd. outdoor temperatureT-return return temperatureirradiation solar irradiationfow rate fow rate

    Abbreviations sensors

    relay descriptionR1 lter pumpR2 pump (P2) a terheatingR3 signal relayR4 operationR5 valve (V1) open (solar pump)R6 valve (V1) closedR7 a terheating demand potential- ree

    Abbreviations - relays

    filter

    heating

    heat.

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    7 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    8/20

    3. Operation and unction3.1 Buttons or adjustment

    132

    (-) backwards orwards (+)

    SET / OK(selection / adjustment mode)

    control lamp

    The controller is operated via the 3 push buttons below thedisplay. The orward-button (1) is used or scrolling orward

    through the menu or to increase the adjustment values. Thebackward-button (2) is similarly used or scrolling backwardsand reducing values. Button 3 is used or selection o themenu lines and or con rmation.

    Brie y press button 3 in order to get to the mainmenu

    Select the requested menu using buttons 1 and 2. Brie y press button 3, the selected submenu is then

    shown on the display. By selecting the menu lineback, the display returns to the ormer menu level.

    Press buttons 1, 2 and 3 to scroll until the choosenmenu line is reached.

    Brie y press button 3 in the respective menu line tomodi y adjustment values, adjust the requested valueby pressing the buttons 1 and 2 ( or large intervals,keep the button pressed).

    Brie y press button 3 in order to nish the adjustment. To save the change, answer the security inquiry

    Save? by choosing yes or no (buttons 1 and 2)and con rm with button 3.

    When button 3 is pressed or 2 seconds, thedisplay changes back to the main menu.

    3.2 Control lampThe controller is equipped with a red-/green control lamp.The ollowing control and system status are signalled:

    green: automatic operation

    red ashing: malfunction of the system green ashing: manual mode

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 8

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    9/20

    3.3 Menu structure

    Adjustment and control o the controller are carried outvia the menu. When the controller is commissioned, the

    display level is in the status menu. In the rst line o eachsubmenu you will nd the option back, by means o whichit is possible to get to the ormer menu level. In the ollow-ing diagrams you will nd the complete menu contents;since some o the menu points depend on the system, op-tion or message, in some cases not all o the shown textlines are indicated.status is shown on the display in the initial state. A selec-tion can be made between 7 submenus.

    Note:The choice o adjustment values and options depends on

    di erent unctions and the user code. Some only appearin the display i they are available or the adjusted systemparameters.

    Main menu1. Status2. WMZ3. Balances4. Manual operation5. Adj. values6. User code7. Expert

    The clear-text display shows a 4-line part o the selectedmenu.

    3.4 User code1. Expert Code 0077

    All menus and adjustment values are shownand all values can be altered.

    Note:A ter the menu point user code has been chosen, enterthe user code!

    I you do not enter the expert user code, the expertmenu will not be displayed.

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    9 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    10/20

    3.5 Menu overview

    Main menu

    StatusWMZ

    Balance values

    Manual operation

    Adj. values

    User code

    ExpertAdjust. values

    back

    Poolmax.D T onD T o

    Min.on

    Min.o

    Filtre min.

    WMZ

    back

    WMZ1

    WMZ module

    Options

    Expert

    back

    Adj. values

    Options

    Sensors

    Language

    Options

    back

    Flow max.

    CS on

    A ter heat.

    AH sol. opt.

    Col. Sec.

    Col. Min.

    Signal relay

    Operat. relay

    CirculationPool cool.

    Extra circ.

    Ext. on/o

    Pump monitor

    Reset

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 10

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    11/20

    4. Commissioning

    132

    SET / OK(selection / adjustment mode )

    control lamp

    Adjust date and time in the Status menu.

    5. Functions and options

    Adjust the minimum runtime, in minutes.

    Period o time during which the system has to run at leasta ter the switch-on condition has been ul lled. The mini-mum switch-on will not be interrupted by the swimmingpool maximum temperature limitation.

    Adjust the minimum break time, in minutes.

    Period o time during which the system has to stand still atleast a ter the switch-o condition has been ul lled.

    Minimum runtimeAdj. values/Min. onadjustment range: 1 ... 10 min

    actory setting: 2 min

    Minimum break timeAdj. values/Min. off

    adjustment range: 1 ... 10 minactory setting: 2 min

    Maximum pool temperatureAdj. values/Pool max.adjustment range: 10,0 ... 40,0 C

    actory setting: 30,0 C

    Adjust the maximum pool temperature, in C.

    When the adjusted swimming pool temperature is reached,the solar system switches o . The circulation unction willnot be suppressed.

    Switch-on di erenceAdj. values/ D T onadjustment range: 3,5 ... 20,0 K

    actory setting: 5,0 K

    Switch-o di erenceAdj. values/ D T offadjustment range: 0,5 ... 19,5 K

    actory setting: 3,0 K

    Adjust the switch-on di erence or the solar circuit, inKelvin.

    Adjust the switch-o di erence, in Kelvin. The switch-o di erence must be by at least 0,5 K smaller than the switch-on di erenceD Ton.

    (-) backwards orwards (+)

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    11 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    12/20

    Adjust the minimum runtime o the lter pump, in hours.

    The pump will be switched on every day or this period o time. This adjustment value is variable and has to be passedthrough until the re erence point (07:00 p.m.).

    Example: When the lter runtime is adjusted to 5 hours,the ilter pump has to start at 02:00 p.m. andcontinuously run until 07:00. p.m.

    The minimum lter runtime will also be maintained in thecase o a sensor ault.

    Minimum lter runtimeAdj. values/Circ. min.adjustment range: 0 ... 16 h

    actory setting: 5 h

    Flow maximum limitationExpert/Options/Flow max.and adjust:Expert/Adj. values/T-FLmax.adjustment range: 30 ... 90 C

    actory setting: 40 CExpert/Adj. values/ D T-FLsec.adjustment range: 0,2 ... 10,0 K

    actory setting: 2,0 K

    Adjust the maximum limitation o the fow.

    I this unction is activated, solar loading is stopped whenthe maximum fow temperature has been exceeded. Thepool will be loaded again, i the fow temperature alls byD T fowmax. below the maximum fow temperature.The adjustable minimum di erence between switch-ontemperature and switch-o temperture (hysteresis) avoidsthat the controller switches on and o again at too lowtemperature di erences.

    Manual operationManual operation/All relays or:Manual operation/Relay 1 etc

    Each relay can be set into on-/o -/or automatic mode.During normal operation the relay is in automatic mode.

    CSExpert/Options/CS onand adjust:

    Expert/Adj. values/CS onadjustment range: 100 ... 700 W/qmactory setting: 300 W/qm

    The pool will be loaded i the adjusted irradiation threshold(CS-Bypass) at the irradiation sensor is exceeded or i there is a temperature di erence caused by high absorbertem peratures. CS on can be activated; the irradiation

    threshold is adjustable (100-700 W/m).

    Heat quantity measurementWMZ/Options/WMZselection:WMZ Yes or No

    Heat quantitiy measurement is possible with the di erencebetween fow and return temperature, and with the fowrate indicated by the fowmeter.If WMZ is selected, ow temperature, return temperature,fow rate and heat quantity will be displayed.It is possible to use an additional WMZ module. Flow tem-

    perature, return temperature, fow rate and heat quantitywill also be displayed.

    WMZ/WMZ module Yes or No

    Switch-on delayExpert/Adj. values/t- D Tonadjustment range: 0 ... 300 s

    actory setting: 20 s.

    Adjust the D Ton time.

    The switch-on condition has to be ul lled or this periodo time or solar loading to start.

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 12

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    13/20

    WMZ/WMZ1/Expert

    WMZ/WMZ1/Expert/Sen. flowadjust to 3WMZ/WMZ1/Expert/Sen. returnadjust e.g. to 5

    WMZ/WMZ1/Expert/Flowmeterselection Yes

    - Anti reeze type:0 or water;1 or propylene glycol;2 or ethylene glycol;3 or Ty ocor LS

    - Adjust volume/pulse (in l)WMZ/WMZ1/Expert/Vol/puls.

    adjustment range: 0,5 ... 100,0 lactory setting: 1,0 l

    I a fowmeter is used (Yes), a pulser is used or measuringthe fow rate.

    A terheatingExpert/Options/After heat.and adjust to:Expert/Adj. values/AH onadjustment range: 10 ... 39,7 C

    actory setting: 24 CExpert/Adj. values/AH offadjustment range: 24,3 ... 40,0 C

    actory setting: 24,5 C

    When the temperature alls below the minimum tempera-ture (AH on), a terheating is switched on and heats the pooluntil it reaches the desired temperature (AH o ).

    The value AH on has to be by 0,3 K smaller then thevalue AH o .

    Adjust the ratio o the water/glycol mixture.Adjusting the anti reeze concentrationWMZ/WMZ1/Expert/Antifreezeadjustment range: 20 ... 70 Vol %

    actory setting: 40 %

    Anti reeze typeWMZ/WMZ1/Expert/Antifreeze typeadjust e.g. to 1

    Heat quantity measurement with and withoutfowmeter

    I you select the Expert submenu, you can urther choosebetween:- Sensor fow/return: here you can re-allocate the sensors,i you do not use the sensors which have already been pre-

    allocated.

    When no fowmeter has been selected (No), a fow ratevalue has to be entered as well as the relay which is to beused or the heat quantity measurement.

    WMZ/WMZ1/Expert/Flowmeter.selection NoWMZ/WMZ1/Expert/Relay

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    13 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    14/20

    Circulation unctionExpert/Options/Circulationand adjust:

    Expert/Adj. values/Circ. timeadjustment range: 1 ... 10 min

    actory setting: 1 min

    When the solar thermal system has been o or 1 hour, itis switched on or 1 ... 10 minutes (the water o the swim-ming pool circulates through the pipes; this allows the pooltemperature to be detected during system standstill). I thefow emergency shutdown is active, the circualtion unctionis suppressed.

    Adjust the circulation runtime, in minutes.

    Beginning and end o circulation (clock time).

    Absorber minimum limitationExpert/Options/Abs. min.and adjust:Expert/Adj. values/TColminadjustment range: -25 ... 90 C

    actory setting: 10 CExpert/Adj. values/ D T Colminadjustment range: 0,3 ... 10 K

    actory setting: 5,0 K

    This unction makes sure that solar loading will start only i the absorber temperature reaches the adjusted value.

    Absorber emergency shutdownExpert/Options/Abs. max.and adjust to:Tcol. sec.adjustment range: 60 ... 160 C

    actory setting: 130 CD T col. sec.adjustment range: 2 ... 50 K

    actory setting: 10 K

    Absorber emergency shutdown temperature, adjustablebetween 60 and 160C.

    I the adjusted temperature threshold (Tcol. sec.) is ex-ceeded, the pool will no longer be loaded by the absorber.

    A terheating optimisationExpert/Options/AH sol. opt.and adjust:Expert/Adj. values/AH Sol. on

    adjustment range: 2,0 ... 20,0 Kactory setting: 2,0 K

    Expert/Adj. values/AH Sol. offadjustment range:1,0, ... 19,7 K

    actory setting: 1,5 KExpert/Adj. values/ D TAH. Solaradjustment range: 0,3 ... 20,0 K

    actory setting: 1,0 K

    The unction starts when the pool is being loaded. Solar loa-ding means that pool loading is only carried out or energysupply and not or cooling purposes etc.

    A terheating is suppressed when the temperature di erence

    between fow and pool (AH solar on) is reached. I the tem-perature di erence alls below the value AH solar o , theoptimisation unction switches o .The adjustable minimum di erence between switch-on tem-perature and switch-o temperture (hysteresis) avoids thatthe controller switches on and o again at too low tempe-rature di erences.

    Expert/ Adj. values/Circ. startactory setting: 07:00

    Expert/Adj. values/Circ. stop

    actory setting: 19:00

    The adjustable minimum di erence between switch-ontemperature and switch-o temperture (hysteresis) avoidsthat the controller switches on and o again at too lowtemperature di erences.

    The adjustable minimum di erence between switch-on temperatureand switch-o temperture (hysteresis) avoids that the controllerswitches on and o again at too low temperature di e-rences.

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 14

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    15/20

    Extra lter runtimeExpert/Options/Extra circ.and adjust:Expert/Adj. values/Extra circ.

    adjustment range: 1 ... 20 hactory setting: 2 h

    This option is used or switching on an extra runtime o thelter pump (in h) i necessary (e.g. in the case o polluted

    pool water).

    As soon as a contact is detected at the Din input, the lterpump starts and remains switched-on or the adjusted periodo time (extra runtime). The lter minimum runtime will notbe infuenced by this unction.

    External release

    Expert/Options/Ext. on/off

    The external release unction is used or releasing the pumpor solar loading (e.g. or preventing the controller rom

    switching on the pump during pump maintenance.) TheDin input must be closed to deblock the controller (solarloading, a terheating).

    Pool cooling unctionExpert/Options/Pool cool.and adjust: Expert/Adj. values/ D T-Cool.adjustment range: 0,5 ... 10,0 K

    actory setting: 2,0 KExpert/Adj. values/ D T Cool onadjustment range: 1,8 ... 10,0 K

    actory setting: 3,0 KExpert/Adj. values/ D T Cool offadjustment range: 0,3 ... 9,7 K

    actory setting: 1,5 K

    I the maximum pool temperature is exceeded by theadjusted value ( D T-Cool), heat is diverted, provided thatthe absorber is by at least D TCool on colder than thepool. Cooling is switched o when the value D TCool O

    is reached.

    Filter pump monitoringExpert/Options/Pump monitorselection Yes or No

    When fowmeter is used and when the the lter pump is

    switched on, this option monitors whether there is a fowrate in the solar circuit. I the controller does not receiveany pulse a ter 2 minutes, the lter pump will be switched-o and an error message will be generated.

    Adjust the sensor type or the solar irradiation sensor(A to E).

    Sensors:

    Expert/Sensors

    Expert/Sensors/CS-typeAdjust the sensor o set.

    An o set (-5K ... +5K, in 0,1 K steps) can be allocatedto each sensor in order to match the sensors with eachother.

    Expert/Sensors/CS adjust

    Expert/Sensors/CS offset

    Expert/Sensors/Sensor 1 etc.

    The adjustable minimum di erence between switch-ontemperature and switch-o temperture (hysteresis) avoidsthat the controller switches on and o again at too lowtemperature di erences.

    Operating relay:Expert/Options/Operat. relayselection: Yes or No.

    The operating relay option can be selected. I the operatingrelay is selected (Yes), it is energised when the pool isbeing loaded.

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    15 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    16/20

    6. Messages

    In the case o a sensor ault, an error message is generated:

    Sensor de ective.

    Furthermore, the de ective sensor will be recognised (ab-sorber sensor, pool sensor or fow temperature sensor).

    Sensor ault

    ! Sensor faulty> Absorber

    Signal relay (error message)

    Expert/Options/Signal relay

    This function is switched on (option WMZ), when the

    controller detects a ault. In this case, the signal relay isenergised (e.g. or signal lights).

    These errors are:

    sensor defective

    pump defective

    real-time-clock (RTC) defective

    storage module (EEPROM) defective

    Please note that a message caused by one o the plausibilitycontrols does not activate the relay.

    ! Sensor faulty

    ! Pump

    !RTC

    !EEPROM

    Reset:

    Expert/Options/Resetselection: Yes or No.

    The reset option can be selected. When the reset option isselected (Yes), the controller settings are set back to the

    actory settings.

    Language:

    Expert/Language/English

    Language choice: German, English, French, Castellano, Italiano.

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 16

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    17/20

    Messages The ollowing states can be displayed:

    display description

    Everything OK normal operation o the system, no mal unction

    Controller off controller is switched o > Contr. ext. off controller has been switched o by the operator

    !Pump faulty! pump is de ective

    !Sensor faulty sensor is de ective

    >Absorber identi cation o the de ective sensor

    >Pool see above.

    >Flow see above

    WMZ off WMZ (heat quantity measurement) is deactivated

    !Sensor faulty sensor is de ective

    >Flow identi cation o the de ective sensor>Return see above

    !EEPROM EEPROM de ective

    !RTC RTC de ective

    Solar on solar loading is active

    Solar off solar loading is switched o

    Min . on minimum runtime is active

    Min . off minimum break time is active

    Solar CS on CS irradiation sensor option is active

    Solar Pool max. maximum swimming pool temperature has been reached

    Solar Flow max. fow emergency shutdown is active

    Solar Cooling cooling is active

    Circ. on lter pump is switched on

    Circ. off lter pump is switched o

    Circ. min. on lter pump minimum runtime is activated

    Circulation circulation option is activated

    Circ. time indication o the lter pump runtime

    AH on a terheating option is activated

    AH off a terheating option is deactivated

    Afterheat. on a terheating is activeAfterheat. off a terheating is not active

    Afterheat. Solar a terheating is active during solar loading

    TAbsor. display o absorber temperature

    Tpool display o pool temperature

    Tflow display o fow temperature

    Toutd. display o outdoor temperature

    Intens. display o irradiation intensity

    Relays display o the individual relay status

    Sensors display o the temperatures at each sensorTime

    Date

    Version 1.00

    0 9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    17 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    18/20

    7. Balance values

    The values shown on the le t can be balanced.Balance values

    Balance/Pool max

    Balance/Colmax

    Balance/Flow max

    Balance/B-rel1

    Balance/B-rel2

    Balance/B-rel3

    Balance/B-rel4

    Balance/B-rel5

    Balance/B-rel6

    Balance/B-rel7

    Balance/Oper. days

    8. TroubleshootingThe de ective sensor (swimming pool sensor, fow tempe-rature sensor, absorber sensor) is indicated on the display.The solar thermal system will be switched o or not putinto operation.

    Operating hours o the individual relays.

    0

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    | 18

    DeltaSol Pool

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    19/20

    use T4Aspare use T4A

    In the case o a mal unction, a message is shown on thedisplay o the controller.

    control lamp

    Operating control lamp o

    Check the power supply

    o.k.

    The use o the controller could be blown.It can be replaced a ter the ront coverhas been removed (spare use is enclosedin the accessory bag).

    Operating control lamp fashes red. The symbol andthe are shown.

    Sensor ault. An error code instead o a temperature is shown on the sensordisplay channel.

    - 88.8888.8

    Cable is broken.Check the cable.

    Short-circuit.Check the cable.

    Disconnected Pt1000 temperature sen sorscan be checked with an ohmmeter. In the

    ollowing table, the resistance valuescorresponding to di erent temperaturesare listed.

    Resistance values o the Pt1000 sensors

    0

    9 3 0 3

    _ D e l t a

    S o l _ P o o l . m o n e n . i n

    d d

    19 |

  • 8/6/2019 49009760_SunMaxx_DeltaSol_Pool_115V.monen

    20/20

    10. Accessory

    Overvoltage protection device

    In order to avoid overvoltage damage at collector sensors(e.g. caused by local lightning storms), we recommend in-stalling the overvoltage protection SP10.

    Sensors

    Our product range includes high-precision platin tempe-rature sensors, fatscrew sensors, outdoor temperaturesensors, indoor temperature sensors, cylindrical clip-onsensors and irradiation sensors, also as complete sensorswith immersion sleeve.

    Distributed by: Silicon Solar Inc.15 Catherwood Ave,14850 Ithaka, NYUSA

    Please note:The design and the speci cations can be changed without notice.

    Reprinting / copyingThis mounting- and operation manual including all partsis copyrighted. Another use outside the copyright requiresthe approval o Silicon Solar Inc.. This especially applies orcopies, translations, micro lms and the storage into elec-tronic systems.Editor: Silicon Solar Inc.

    Important notice :The text and drawings in this manual are correct to thebest o our knowledge. As aults can never be excluded,please note: Your own calculations and plans, under con-sideration o the current standards and DIN-directionsshould only be basis or your projects. We do not o er aguarantee or the completeness o the drawings and textso this manual - they only represent some examples. Theycan only be used at your own risk. No liability is assumed

    or incorrect, incomplete or alse in ormation and / or any

    resulting damages.

    9 3 0 3

    _ D e

    l t a S o

    l _ P o o l . m o n e n . i n

    d d

    DeltaSol Pool