Menvier FirePanels
MF200 / 400 series
Supplied with battery & end of line devices
72 hour standby option (MF400)
One man walk test facility
Large choice of cable entries
Menvier Fire Panels
MF9300 series
Up to 32 detectors per zone
72 hour standby on standard version
One man walk test facility
Non-latching zone facility
Flush or surface mounting
46 Conventional Fire
-
CATALOGUE NUMBERS
W
H
D
W
H
D2
D1
DIMENSIONS
Cat No Number Standby Weight
of Zones Duration (hrs) (kg)
Menvier MF200 / 400 PanelsMF200 2 24 4.8
MF400 4 24 4.8
MF400-72 4 72 6.0
Menvier MF9300 PanelsMF9302 2 72 10.6
MF9304 4 72 10.6
MF9308 8 72 16.8
MF9316 16 72 16.9
MF9308-L 8 24 16.0
MF9316-L 16 24 16.0
Menvier MF9300 Repeater PanelsMFR9308 8 72 16.8
MFR9316 16 72 17.2
Cat No Description
Optional AccessoriesMAR424 Fire and fault relay PCB
for MF200/400
H W D
(mm) (mm) (mm)
300 300 74
H W D1 D2 Cut-out
(mm) (mm) (mm) (mm) (mm)
2/4 zone 344 395 25 70 324 x 385
8/16 zone 386 395 25 119 376 x 385
Note: If surface mounting, add D1 & D2 to obtain depth
dimension
TECHNICAL SPECIFICATION
Panel Catalogue No MF200 MF400 MF9302 MF9304 MF9308 MF9316
Number of Zones 2 4 2 4 8 16
Detectors Per Zone 20 32
Number of Alarm Circuits 2 2 4
Alarm Circuit Load 375mA per circuit. 750mA total 500mA per
circuit. 1A total
End of Line Devices Detection circuits: 22KΩ resistor Detection
circuits: 12KΩ resistor
Alarm lines: 22KΩ resistor Alarm lines: 12KΩ resistor
Auxiliary Fire Signal Output 24V DC pull to 0V. Max 10mA 1A 24V
DC (resistive) single pole change over contacts. Isolate facility
available
Auxiliary Fault Output 24V DC pull to 0V. Max 10mA 1A 24V DC
(resistive) single pole changeover contacts
Auxiliary Common Output 24V DC pull to 0V. Max 10mA
Auxiliary DC Output 24V DC fused. (up to 100mA 32mA 24V DC
fused. 100mA 24V DC fused. 350mA
at the expense of alarm load)
Repeater Output 2 wire serial link (Repeater also requires
separate 230V AC supply)
Mains Input Voltage 240V AC +10%-15% 230V AC ±10%. 50/60 Hz
System Operating Voltage 24V DC
Standby Duration 24 hours (72 hours on MF400-72) 72 hours (24
hours option on 8 & 16 zone)
Battery 1 x 4AH sealed lead acid battery 1 x 7AH sealed lead
acid battery 1 x 12AH sealed lead acid battery
(1 x 7AH on MF400-72)
Recharge Period 48 hours (80% in 24 hours) 24 hours
Panel Construction ABS/Polycarbonate housing. ABS/Polycarbonate
ABS/Polycarbonate
Steel back box. housing & back box housing & steel back
box
Cable Entries Top: 10 x 20mm knockout Top: 13 x 20mm knockouts
Top: 27 x 20mm knockouts Back:
Bottom: 1 x 20mm knockout back: 1 x 20 mm knockouts back: 1 x 20
mm knockouts
Back: 1 x mains cable entry slot
Environmental Rating IP30. -5°C to +40°C. IP20. -5°C to
+40°C
Humidity 75% max (non-condensing) Humidity 75% max
(non-condensing)
-
JSB Fire PanelsFX4200 series
Complies with EN 54
Supplied with battery & end of line devices
Simple ‘one shot’ auto reset user test facility
Programmable fire / fault output relay
JSB Fire Panels
FX2200 series
Approved to EN54
Supplied with battery & end of line devices
Choice of 1,2,4 or 8 zones
Maintenance free polyswitch circuit protection
Custom configured versions available
FX2200 BW series
Quick and simple to install
Detectors & sounders share same pair of wires
Choice of 1,2,4 or 8 zones
Custom configured versions available
48 Conventional Fire
-
CATALOGUE NUMBERS
Cat No of Standby Weight
No Zones Duration (kg)FX4202 2 24 hrs 4.8
FX4204 4 24 hrs 4.8
PanelsFX2201 1 24 hrs 5.1
FX2202 2 24 hrs 5.2
FX2204 4 24 hrs 5.8
FX2208 8 24 hrs 6.0
Panels - configured for use with a repeaterFX2202CR 2 24 hrs
5.8
FX2204CR 4 24 hrs 6.0
Repeater PanelFXRP2200 8 24 hrs 6.0
PanelsFX2201BW 1 24 hrs 5.1
FX2202BW 2 24 hrs 5.2
FX2204BW 4 24 hrs 5.8
FX2208BW 8 24 hrs 6.0
W
H
D
H W D
(mm) (mm) (mm)
300 300 74
W
H
D2
D1
1 2 3 4 5
SCROLLMUTEBUZZER
Recessed H W D1 D2 Cut-out
(mm) (mm) (mm) (mm) (mm)
2/4/8 zone 270 332 45 47 265 x 327
Surface H W D
(mm) (mm) (mm)
1 zone 212 260 72
2/4/8 zone 270 332 92
DIMENSIONS
Panel Catalogue No FX4202 FX4204 FX2201/ FX2202/ FX2204/
FX2208/
FX2201BW FX2202BW FX2204BW FX2208BW
Number of Zones 2 4 1 2 4 8
Detectors per Zone 20
Number of Alarm Circuits 2 4
Alarm Circuit Load 150mA per 400mA per 150mA per circuit 500mA
per circuit, 2A total,
circuit 0.3A total circuit 0.8A total 0.3A total 150mA per
zone
End of Line Devices Detection circuits: EOLM-1 monitoring unit
Alarm lines: 6.8KΩ resistor
Auxiliary Fire Signal/Fault Output 5A 24V DC single pole
changeover contacts
Auxiliary DC Output 24V DC fused. 30mA_
Mains Input Voltage 230V AC -10% +15%
System Operating Voltage 24V DC
Standby Duration 24 hours
Battery (sealed lead acid) 1 x 3.2AH 2 x 3.2AH
Recharge Period 24 hours
Panel Construction Polycarbonate housing & back box
Cable Entries Top: 10x20 mm conduit entries Top: 6x20mm Top:
12x20mm Top: 12x20mm
Bottom: 10x20 mm conduit entries entries with entries with
entries with
Back: 1x mains cable entry slot blanking plugs blanking plugs
blanking plugs
Rear cable Rear cable Rear cable
entry aperture entry aperture entry aperture
Environmental Rating IP30. -5°C to +40°
Humidity 75% max (non-condensing)
TECHNICAL SPECIFICATION
FX2200
FX4200
-
ConventionalDetectors and
BasesJSB and Menvier Detectors
LPCB approved
Drift Compensation
Ultra low profile, 360° viewing angle LED
Photo thermal alternative to old ionisation types
Conventional Detectorsand Bases
Self Test Detectors
Constantly checks and confirms detector operation
Triggers fault locally and at panel in event of fault
Drift compensation
New patented technology
Enhanced integrity for conventional systems
Detector Bases
Selectable detector locking feature
Separate loop in and out connections
Base incorporates features to supportsurface wiring
50 Conventional Fire
-
CATALOGUE NUMBERS
Description Cat No to suit Cat No to suit Cat No to suit
Menvier systems JSB systems JSB Bi wire systems
Enhanced optical smoke detector MPD821 FXN533 FXN623
Enhanced photo thermal detector MPT951 FXN632 FXN622
Fixed heat detector (77°C) MMT860 FXN524 FXN624
Fixed heat detector (92°C) MHT890 FXN526 FXN626
Rate of rise heat detector MFR830 FXN525 FXN625
Common base MDB800 FXN520 FXN520
Cat No Description
FXN523ISC JSB Self Check optical conventional detector
FXN524ISC JSB Self Check conventional heat detector (77°C)
FXN525ISC JSB Self Check conventional heat detector (Rate of
rise)
FXN526ISC JSB Self Check conventional heat detector (92°C)
FXN622ISC JSB Self Check combined photo/thermal conventional
detector
FXN520 JSB common mounting base
Dia D (excluding base) D (including base)
(mm) (mm) (mm)
Optical smoke detectors 101 33 45
Photo-thermal detector 101 43 55
Heat detectors 101 43 55
DIMENSIONS
Dia
D
-
ConventionalSounders
Conventional Sounders
Speech • 100dB(A) output• Clear intelligible human speech
Flush Electronic • Low profile design• Volume control
Ceiling Mounted • Reduced install time• Optional blanking plate
when
used without a detector
Staff Warning • Discrete audible and visual alarm
• Twin high intensity LED’s
Surface Low • Choice of colourProfile • 32 selectable tones
Surface • Weatherproof designWeatherproof • Choice of cable
entry
High Output • Ideal for areas with highambient noise
Low Current • High efficiency design
52 Conventional Fire
-
CATALOGUE NUMBERS
Cat No Description Message Version Weight (kg)
MSS7MR 24V Menvier speech sounder (red) A 0.3
MSS20MR 24V Menvier speech sounder (red) B 0.3
MSS28MR 24V Menvier speech sounder (red) C 0.3
MSS7MW 24V Menvier speech sounder (white) A 0.3
MSS20MW 24V Menvier speech sounder (white) B 0.3
MSS28MW 24V Menvier speech sounder (white) C 0.3
Dia D
(mm) (mm)95 105
Cat No Description Weight (kg)
MFS324 Menvier red flush sounder 0.3
MFS324W Menvier white flush sounder 0.3
FX003 JSB flush sounder (red) 0.3
H W D
(mm) (mm) (mm)86 86 36
Cat No Description Weight (kg)
MDS824 Menvier detector base sounder 0.4
MDS824B Menvier detector base sounder beacon 0.4
MDS824COV Blanking plate 0.1
Dia D
(mm) (mm)111 26
Cat No Description Weight (kg)
MAS175 Staff warning device 0.24
H W D
(mm) (mm) (mm)89 150 58
Cat No Description Weight (kg)
MWS424SB Menvier low profile surface sounder (red) 0.24
FX002 JSB low profile surface sounder (red) 0.24
FX002W JSB low profile sounder (white) 0.24
Dia D
(mm) (mm)93 63
Cat No Description Weight (kg)
MWS424DB Menvier weatherproof surface sounder (red) 0.3
Dia D
(mm) (mm)93 93
Cat No Description Weight (kg)
FX007 JSB high output conventional sounder (red) 0.28
H W D
(mm) (mm) (mm)105 105 95
Cat No Description Weight (kg)
MLC624 Menvier low current conventional sounder (red) 0.25
H W D
(mm) (mm) (mm)105 105 95
DIMENSIONS
Dia
D
Dia
D
H
W
Dia
D
D
H
W
D
Dia
D
D
W
H
H
W
D
-
ConventionalFire Beacons
Conventional FireBeacons
Xenon
High light output
Weatherproof version supports side entrysurface cables
Unobtrusive low profile design
Xenon Sounder
Sounder & Beacon with a single installation point
Weatherproof version IP65
LED
Low profile consumption
Discrete low profile design
Choice of Flashing frequency
LED Sounder
Sounder & Beacon with a single installation point
Choice of cable entries
Weatherproof version
54 Conventional Fire
-
Lamp L W D Lamp L W DRating (mm) (mm) (mm) Rating (mm) (mm)
(mm)
T8/12 lamps1x18W 627 58 92 2x18W 627 89 921x36W 1238 58 92 2x36W
1238 89 921x58W 1538 58 92 2x58W 1538 89 921x70W 1802 58 92 2x70W
1802 89 921x100W 2413 58 92 2x100W 2413 89 92T5 lamps1x14/24W 627
58 80 2x14/24W 627 58 801x28/54W 1238 58 80 2x28/54W 1238 58
801x35/49W 1538 58 80 2x35/49W 1538 58 80
R
R
R
R
R
R
CATALOGUE NUMBERS
Cat No Description
MXB124SB Menvier low profile Xenon beacon (red lens)
FX004R JSB low profile Xenon beacon (red lens)
FX004A JSB low profile Xenon beacon (amber lens)
FX004B JSB low profile Xenon beacon (blue lens)
CATALOGUE NUMBERS DIMENSIONS
Dia D
(mm) (mm)93 72
Cat No Description
MXB124DB Menvier low profile Xenon beacon
Cat No Description
MCD524SB Menvier low profile combined sounder beacon (red
lens)
FX002CR JSB low profile combined sounder beacon (red lens)
FX00 2CA JSB low profile combined sounder beacon (amber
lens)
FX002CB JSB low profile combined sounder beacon (blue lens)
Dia D
(mm) (mm)93 92
Cat No Description
MCD524DB Menvier weatherproof sounder beacon
Dia D
(mm) (mm)93 121
Cat No Description
MLB124SB Menvier low profile LED beacon
FXN004BW Bi wire LED beacon
Dia D
(mm) (mm)95 53
Cat No Description
MLB124DB Menvier weatherproof LED beacon
Dia D
(mm) (mm)95 80
Cat No Description
MSB124SB Menvier low profile LED sounder beacon
Dia D
(mm) (mm)93 80
Cat No Description
MSB124DB Menvier weatherproof combined LED sounder beacon
Dia D
(mm) (mm)95 109
Dia D
(mm) (mm)93 101
D
Dia
Dia
D
Dia
D
Dia
D
Dia
D
Dia
D
Dia
D
Dia
D
-
ConventionalFire Ancillaries
Conventional FireAncillaries
Bells
High sound output
Low current consumption
Weatherproof version
Call Points
Fast fit clip on front cover
Heavy duty terminals
Weatherproof version
Door Retainers and Relays
Mains and 24V versions
Manual release facility
Optional Floor bracket
56 Conventional Fire
-
CATALOGUE NUMBERS DIMENSIONS
Cat No Description
MBM244 100mm Metal bell (Menvier)
MBM246 150mm Metal bell (Menvier)
MBM248 200mm Metal bell (Menvier)
FX006 150mm Metal bell (JSB)
Cat No Description
MWB824 200mm Weatherproof metal bell
Dia D
(mm) (mm)200 104
Cat Dia D
No (mm) (mm)
MBM244 100 63
MBM246 152 63
MBM248 203 63
FX006 152 63
Cat No Description
MBG914 Surface callpoint to suit Menvier systems
MBG913 Flush callpoint to suit Menvier systems
MBG917 Weatherproof surface callpoint to suit Menvier
systems
MBG914L Surface callpoint c/w LED to suit Menvier systems
MBG917L Weatherproof surface callpoint c/w LED
FX201 Surface callpoint to suit JSB conventional systems
FX201L Surface callpoint c/w LED to suit JSB systems
FX203 Weatherproof surface callpoint to suit JSB systems
FX203L Weatherproof surface callpoint c/w LED
W D H
Description (mm) (mm) (mm)
Flush callpoint 87 36 87
Surface callpoint 87 57 87
Weatherproof callpoint 108 70 108
Cat No Description
FX021240LC Compact magnetic door retainer (mains powered)
FX02124VLC Compact magnetic door retainer (24V DC powered)
FX021LCFB Floor mounting bracket for compact door retainer
H W D
Description (mm) (mm) (mm)
Magnet 71 108 44
Sticker plate 65 65 48
Cat No Description
MDR240 Heavy duty magnetic door retainer (mains powered)
MDR24L Heavy duty magnetic door retainer (24V DC powered)
ZMDRFBB Floor mounting bracket for heavy duty door retainer
H W D
Description (mm) (mm) (mm)
Magnet 95 95 40
Sticker plate 65 65 48
Cat No Description
MAR724 Heavy duty relay
W H D
(mm) (mm) (mm)150 89 58
Cat No Description
FX251D Remote indicator unit
W H D
(mm) (mm) (mm)87 87 30
H
D
Dia
Dia
D
W W
H
D D
HH
WW
DD
WW
HH
D
D
W
H
D
W
H
D