4-Methylamphetamine The Drug Enforcement Administration's Special Testing and Research Laboratory generated this monograph using structurally confirmed reference material. Page 1 of 5 SWGDRUG.org/monographs.htm Latest Revision: 01/15/2014 Page 1 of 5 CH 3 NH 2 C H 3 1. GENERAL INFORMATION IUPAC Name: 1-(4-methylphenyl)propan-2-amine CAS#: 22683-78-9 (Base), 41632-56-8 (HCl) Synonyms: 4-MA, PAL-313, Aptrol, p-TAP, p-methylamphetamine Source: DEA Reference Material Collection Appearance: White powder (HCl) UV max (nm): Not Determined 2. CHEMICAL AND PHYSICAL DATA 2.1 CHEMICAL DATA Form Chemical Formula Molecular Weight Melting Point ( o C) Base C 10 H 15 N 149 Not Determined HCl C 10 H 15 N . HCl 185 149.9
5
Embed
4-Methylamphetamine - SWGDRUG · 4-Methylamphetamine The Drug Enforcement Administration's Special Testing and Research Laboratory generated this monograph using structurally confirmed
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
4-MethylamphetamineThe Drug Enforcement Administration's Special Testing and Research Laboratory
generated this monograph using structurally confirmed reference material.
Page 1 of 5SWGDRUG.org/monographs.htmLatest Revision: 01/15/2014 Page 1 of 5
Form Chemical Formula Molecular Weight Melting Point (oC)
Base C10H15N 149 Not Determined
HCl C10H15N. HCl 185 149.9
4-MethylamphetamineThe Drug Enforcement Administration's Special Testing and Research Laboratory
generated this monograph using structurally confirmed reference material.
Page 2 of 5SWGDRUG.org/monographs.htmLatest Revision: 01/15/2014 Page 2 of 5
3. QUALITATIVE DATA
3.1 NUCLEAR MAGNETIC RESONANCE
Sample Preparation: Dilute analyte to ~5 mg/mL in deuterium oxide (D2O) containing TSP for 0 ppmreference and maleic acid as quantitative internal standard.
Instrument: 400 MHz NMR spectrometerParameters: Spectral width: at least containing -3 ppm through 13 ppm
Pulse angle: 90o
Delay between pulses: 45 seconds1H NMR: 4-methylamphetamine HCl; Lot ALB238-18; D2O; 400 MHz
4-MethylamphetamineThe Drug Enforcement Administration's Special Testing and Research Laboratory
generated this monograph using structurally confirmed reference material.
Page 3 of 5SWGDRUG.org/monographs.htmLatest Revision: 01/15/2014 Page 3 of 5
3.2 Gas Chromatography/Mass Spectrometry
Sample Preparation: Dilute analyte ~ 4 mg/mL base extracted into chloroform
Instrument: Agilent gas chromatograph operated in split mode with MS detectorColumn: DB-1 MS (or equivalent); 30m x 0.25 mm x 0.25 µmCarrier Gas: Helium at 1 mL/minTemperatures: Injector: 280oC
MSD transfer line: 280oCMS Source: 230oCMS Quad: 150oCOven program:
1) 100oC initial temperature for 1.0 min2) Ramp to 300oC at 12 oC/min3) Hold final temperature for 9.0 min
Injection Parameters: Split Ratio = 20:1, 1 µL injectedMS Parameters: Mass scan range: 30-550 amu
4-MethylamphetamineThe Drug Enforcement Administration's Special Testing and Research Laboratory
generated this monograph using structurally confirmed reference material.
Page 5 of 5SWGDRUG.org/monographs.htmLatest Revision: 01/15/2014 Page 5 of 5
http://en.wikipedia.org/wiki/4-methylamphetamine
4. ADDITIONAL RESOURCES
Davis, S.; Blakey, K.; Rands-Trevor, K. GC-MS and GC-IRD analysis of 2-,3- and4-methylmethamphetamine and 2-, 3- and 4-methylamphetamine.Forensic Science International2012, 220, 67-73.
Westphal, F.; Schäfer, T.; Zechlin, L.; Stoll, S. Identification of 4-Methylamphetamine in a seizedAmphetamine Mixture. Toxichem Krimtech 2011, 78 (Special Issue), 306-315.