Page 1
Confidential Page 1 of 14
Product Change Notice
Huawei PCN SRAN-20120010 (OMB Ver.A Cabinet EOM Notice)
0 Abstract
Manufacture of OMB Ver.A cabinets and components intended for the Distributed Base Station 3900 (DBS3900)
will be discontinued. OMB Ver.C cabinets and components will substitute for OMB Ver.A cabinets and
components respectively for sales. This change notice is for customers who use OMB Ver.A cabinets and
components intended for the DBS3900. OMB stands for outdoor mini box.
The last-buy date is December 31, 2013. The last supply date is June 30, 2014.
The heat exchange unit type As (HEUAs) of OMB Ver.A cabinets can be substituted by the heat exchange unit
type Bs (HEUBs) of OMB Ver.C cabinets. Therefore, the manufacture of HEUAs will be discontinued starting
from December 31, 2013 together with OMB Ver.A cabinets. The last supply date is June 30, 2014. For the
last-buy dates for other components that do not have substitutes, see the DBS3900 life cycle milestone bulletin.
The details are as follows.
1 Supplier Information
Huawei Technologies Co., Ltd.
2 PCN Information
PCN No. SRAN-20120010
PCN Revision Rev:01
PCN Classification B
Milestone Issue date The day when the product change
notice (PCN) is officially issued December 31, 2012
Implementation
date The day when the new part is
available/orderable December 31, 2012
End of marketing
date The day when purchase orders (POs)
for the old part are no longer accepted December 31, 2013
End of
manufacturing
date
The day when the old part is no longer
delivered June 30, 2014
Page 2
Confidential Page 2 of 14
Product Change Notice
End of service
support date The day when service support is no
longer provided See the contract.
3 System and Product Affected
Major System Subsystem Hardware Software Firmware Plug-in
DBS3900 OMB cabinet Y N N N
4 Associated Change
None.
5 BOM Change
New BOM Name Old BOM Name Complete Substitution
02113690 OMB Ver.C cabinet
(AC) 02112832 OMB Ver.A cabinet (AC) Yes
02113691 OMB Ver.C cabinet
(DC) 02112833 OMB Ver.A cabinet (DC) Yes
03021MUP HEUB 03020HJV HEUA Yes (note 1)
02120719 FAU01D-01 02120496 Internal fan unit N/A (note 2)
02120497 External fan unit N/A (note 2)
02310MCA ETP48100-A1 02400421 EPS30-4815AF N/A (note 2)
02310HBJ R4850G2 02130617 GERM4815 N/A (note 2)
02310LYP PMU 11A 02316005 EPMU03 N/A (note 2)
02120722 PDU10D-01 02120494 DC power distribution unit
(PDU) N/A (note 2)
19020168 SPD40/S 02120493 Surge protective device
(SPD) N/A (note 2)
The HEUBs of OMB Ver.C cabinets can totally substitute the HEUAs of OMB Ver.A cabinets. Therefore, the
manufacture of HEUAs will be discontinued starting from December 31, 2013 together with OMB Ver.A cabinets.
Except the HEUAs, other components of OMB Ver.A cabinets cannot be substituted by the components of OMB
Ver.C cabinets. Therefore, the components of OMB Ver.A cabinets and OMB Ver.C cabinets need to be stored
respectively as the spare parts for the OMBs used on the live network.
Page 3
Confidential Page 3 of 14
Product Change Notice
6 Classification Substantiation
1. Manufacture of OMB Ver.A cabinets and components will be discontinued. OMB Ver.C cabinets and
components will substitute for OMB Ver.A cabinets and components respectively for sales.
2. OMB Ver.C cabinets employ new components and deliver enhanced performance and high integration.
By supporting more types of RRUs with higher power, OMB Ver.C increases the heat dissipation
capability. Embedded with baseband units (BBUs), OMB Ver.C cabinets have a maximum power of
450 W. The AC-DC power system capacity increases and the conversion efficiency reaches 96%.
Such features enable the OMB to consume less power and deliver more powerful DC power
distribution capability. In addition, OMB Ver.C cabinets can be identified remotely, which facilitates
asset management and fault diagnosis.
7 Software Version Supporting OMB Ver.C Configuration
Single radio access network 8.0 (SRAN8.0): can automatically identify the earlier and latest versions
of the AC-DC power system in the OMB, ensuring the consistency between the actual power supply
unit (PSU) slot number and the slot number displayed on the M2000.
SRAN6.0 and SRAN7.0: cannot identify the latest version of the AC-DC power system. If OMB
Ver.C is used, the PSU slot number displayed on the M2000 is inconsistent with the actual PSU slot
number.
OMB Ver.A OMB Ver.C
Physical slots
for the AC-DC
power system
SRAN6.0
M2000 display
SRAN7.0
M2000 display
SRAN8.0
M2000 display
Page 4
Confidential Page 4 of 14
Product Change Notice
8 Change Description
8.1 Overall Change Description for OMB Ver.C
Figure 1 OMB Ver.C (AC) components
Figure 2 OMB Ver.C (DC) components
Page 5
Confidential Page 5 of 14
Product Change Notice
8.1.1 OMB Ver.C Cabinet
OMB Ver.C cabinets have the same internal structure as OMB Ver.A cabinets on the live network. While
retaining all the functions of OMB Ver.A cabinets, OMB Ver.C cabinets provide better results in supporting
various RRUs, heat dissipation, power system capacity, conversion efficiency, DC power distribution
capacity, remote identification, and component miniaturization.
Enhanced Performance Ver.A Ver.C
Heat dissipation Maximum BBU power: 250 W
Supporting one 1x80 W RRU
Maximum BBU power: 450 W
Supporting six 2x60 W RRUs
AC-DC power system
capacity 800 W 6000 W
PSU conversion
efficiency 90% 96%
PDU DC power
distribution capacity 2 outputs, 12 A and 4 A respectively 10 outputs, 30 A for each
Remote identification Not supported The OMB cabinet version information can
be remotely obtained on the operation and
maintenance center (OMC), which
facilitates asset management and fault
diagnosis.
SPD miniaturization 391 mm x 55 mm x 54 mm 75 mm x 48 mm x 60 mm
8.1.2 Changes in OMB Appearance, Dimensions, and Installation Space
OMB Ver.C has different appearance and dimensions from OMB Ver.A, and the installation space also
changes.
Figure 3 Appearance and dimensions differences between OMB Ver.A and OMB Ver.C
Page 6
Confidential Page 6 of 14
Product Change Notice
Figure 4 Installation space difference between OMB Ver.A and OMB Ver.C
Version OMB Dimensions OMB Installation Space
OMB Ver.A 600 mm x 240 mm x 390 mm (H x W x D) See Figure 4 .
OMB Ver.C 600 mm x 240 mm x 430 mm (H x W x D)
8.2 OMB Ver.C Component Changes
8.2.1 New Electronic Label Function
In OMB Ver.C, the monitoring board HEUBs in OMB Ver.C cabinets are configured with the remote
identification function. The HEUBs in OMB Ver.C can totally substitute the HEUAs in OMB Ver.A.
The newly added electronic label unit (ELU) is installed in the upper part on the right of the OMB cabinet
door. The ELU reports cabinet version information, which facilitates asset management and fault diagnosis.
Page 7
Confidential Page 7 of 14
Product Change Notice
Figure 5 Change from the HEUA to the HEUB
Figure 6 ELU
Name Version ELU Function
HEUA OMB Ver.A No
HEUB OMB Ver.C Yes
8.2.2 Fan Assembly Change
Use the FAU01D-01 as both the internal and external fan units in the OMB cabinet, because the
FAU01D-01 helps improve the heat dissipation capability of the OMB cabinet and raise the maximum
BBU power to 450 W.
Figure 7 Change in the internal fan unit
Page 8
Confidential Page 8 of 14
Product Change Notice
Figure 8 Change in the external fan unit
Name Version BBU Power RRU Type
Internal fan unit OMB Ver.A 250 W One 1 x 80 W
External fan unit OMB Ver.A
FAU01D-01 OMB Ver.C 450 W Six 2 x 60 W
8.2.3 Change in the OMB Cabinet Cable Outlet Structure
The OMB cabinet cable outlet structure changes to support the outlet of more power cables with greater
diameters.
Hole Diameter on Modules (mm)
Suitable Cable Diameter (mm)
Ver.A
Left Module
Ver.C
Left Module
Ver.A
Right Module
Ver.C
Right Module
φ18 φ18–φ22 1
φ13 φ13–φ18 1
φ11 φ11–φ14 4 6
φ9 φ9–φ10
φ8 φ8 2 6 4
φ6 φ6 7 15
φ4 φ4 2
φ2.5 φ2.5 1 4
Page 9
Confidential Page 9 of 14
Product Change Notice
Figure 9 Change in the OMB cabinet cable outlet structure
8.2.4 Change in the AC-DC Power System (Component of the OMB [AC]))
Capacity of the AC-DC power system in the OMB cabinet increases from 800 W to 6000 W.
Figure 10 Change in the AC-DC power system
Version Name Power System Capacity Maximum Number of PSUs
OMB Ver.A EPS30-4815AF 800 W 1
OMB Ver.C ETP48100-A1 6000 W 2
The new PSU (R4850G2) increases the conversion efficiency from 90% to 96%, consuming less
power.
Figure 11 PSU change
Page 10
Confidential Page 10 of 14
Product Change Notice
Version PSU name PSU Capacity PSU Efficiency
OMB Ver.A GERM4815 800 W/PCS 90%
OMB Ver.C R4850G2 3000 W/PCS 96%
The power monitoring unit (PMU) also changes from the EPMU03 to the PMU 11A.
Figure 12 PMU change
Version Name Functions
OMB Ver.A EPMU03 The PSU GERM4815 of OMB Ver.A is managed.
OMB Ver.C PMU 11A The PSU R4850G2 of OMB Ver.C is managed.
The AC-DC power system of OMB Ver.C delivers greater output currents.
Figure 13 DC output change
Version Name DC Power Distribution Capability
OMB Ver.A EPS30-4815AF 1 x 10 A (fuse) + 1 x 20 A (fuse)
OMB Ver.C ETP48100-A1 1 x 100 A (circuit breaker) + 1 x 100 A (circuit breaker)
The corresponding AC power user interface (UI) also changes.
Page 11
Confidential Page 11 of 14
Product Change Notice
Input Voltage Version Power UI
Single-phase 220 V
AC OMB Ver.A 10 A/1P (2.5 mm
2 cable)
OMB Ver.C 16 A/1P (2.5 mm2 cable)
Dual–live wire 110 V
AC OMB Ver.A 10 A/2P (2.5 mm
2 cable)
OMB Ver.C 16 A/2P (2.5 mm2 cable)
8.2.5 Change in the DC SPD (Component of the OMB [AC])
In OMB Ver.C (AC), the PDU10D-01 is used for DC power distribution, which increases the DC outputs
from 2 (12 A and 4 A respectively) to 10 (30 A for each).
Figure 14 Change in the DC SPD (component of the OMB [AC])
Version Name DC Power Distribution Capability
OMB Ver.A DC PDU 1 x 12 A (circuit breaker) + 1 x 4 A (circuit breaker)
OMB Ver.C PDU10D-01 10 x 30 A (fuse)
8.2.6 SPD Change (Component of the OMB [AC])
The SPD40/S is used as the AC SPD. The SPD40/S occupies less area while enduring a maximum of 40 kA
current.
Page 12
Confidential Page 12 of 14
Product Change Notice
Figure 15 SPD change
(AC Surge protection box: SPD)
Version Name Surge Protection Specifications
Dimensions
OMB Ver.A AC SPD 40 kA 405 mm x 55 mm x 53.5 mm (H x W x D)
OMB Ver.C SPD40/S 40 kA 75 mm x 48 mm x 60 mm (H x W x D)
8.2.7 Change in the DC SPD (Component of the OMB [DC])
In OMB Ver.C (DC), the PDU10D-01 substitutes the direct current distribution unit-03B (DCDU-03B) to
distribute DC power.
The DC power distribution capability greatly improves.
Figure 16 Change in the DC SPD (component of the OMB [DC])
Page 13
Confidential Page 13 of 14
Product Change Notice
Version Name DC Power Distribution Capability
OMB Ver.A DCDU-03B 3 x 12 A (circuit breaker) + 6 x 20 A (circuit breaker)
OMB Ver.C PDU10D-01 10 x 30 A (fuse)
The corresponding DC power UI also changes.
Input Voltage Version Power UI
–48 V OMB Ver.A 16 A/1P (4 mm2 cable)
OMB Ver.C 25 A/1P (4 mm2 cable)
9 Effect of Change
The following table lists the effect of the changes on typical aspects.
Safety Fire Service Communication
No No Yes
The installation space for
OMB Ver.C needs to
change. For details, see
section 8.1.2 "Changes in
OMB Appearance,
Dimensions, and Installation
SpaceError! No bookmark
name given.."
No
Maintenance Reliability Power Traffic
Yes
1) OMB Ver.C supports remote
cabinet identification, which
facilitates asset management
and fault diagnosis.
2) The spare parts for OMB
Ver.C differ from those for
OMB Ver.A. Therefore, their
components should be stored
respectively as the spare parts
for the OMBs used on the live
network.
No Yes
The power distribution
capability of OMB Ver.C
increases.
Yes
OMB Ver.C supports
higher service capacity
configuration,
increasing the data
traffic.
Page 14
Confidential Page 14 of 14
Product Change Notice
10 Document Affected
The DBS3900 Product Description and DBS3900 User Guide are updated.
11 Attachment
None.
12 Remarks
For more information about this PCN, please contact the local sales representatives or technical support
personnel of Huawei.