Top Banner
General Catalogue 2016 www.3f-filippi.com
495

3F Filippi "General catalogue 2016"

Aug 03, 2016

Download

Documents

www.3F-Filippi.com 3F Filippi S.p.A., a leader in the lighting industry with over 60 years of experience, announces the new "General catalog 2016" dedicated to the company's products. It is a publication of about 500 pages, full of images explaining in detail not only the technical specifications of products and innovations, but they represent a collection of securities and business know-how in this area. The "General catalog 2016" is published online on the company website and printed on paper for lighting designers, architects and industry experts, is to consolidate the importance of the company in the lighting industry, thanks to a general overview of the company, history and commitment since 1952 in the production of customized products for different environments: industry, retail distribution, sales areas, sports facilities, transport, schools, offices and cultural places with case histories!
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 3F Filippi  "General catalogue 2016"

General Catalogue 2016

www.3f-filippi.com

Page 2: 3F Filippi  "General catalogue 2016"

Usage instructionsHow to use the 2016 General Catalogue

How to interpret our product Articles

To facilitate using our catalogue, a new page layout is being introduced with this new version to help reading and simplify consultation.We will see in detail how:

New for 2016

New product ranges are highlighted in red and have NEW beside them.

Consulting our product Articles could not be simpler – here’s how:

Productfamily

Number oflight sources

Sourcepower

Tipe ofsource

Tipe ofwiring

Other characteristicsFor example louvres, starters, emergency

wiring...

Series presentation page

In this section the product series are presented, with the characteristics and concepts common to the various versions specified.

Descriptions, articles, codes and prices

In these pages, all products are presented, divided by code, article and price. The specific accessories for the version are also specified.Accessories common to the whole series are grouped in a page at the end of the series.

Legend

This appendix helps understand the information given in the catalogue’s pages.It contains the key to the symbols and codes used and a summary.

It is part of the back cover and opens out.

L 324x14 T5 HF 2M

Page 3: 3F Filippi  "General catalogue 2016"

New

New

New New New

New

New

New

New

New New

Product range

Surface luminaires and suspensions

Recessed luminaires

Systems

This “2016 General Catalogue” is an informative product which is distributed free of charge.

While all efforts have been taken to ensure the accuracy of its contents, 3F Filippi shall not under any circumstances be held liable for errors, omissions, interruptions or

delays concerning the information provided in the Catalogue, or for any resulting damage.

The data listed in this Catalogue may be approximate: please visit our website at www.3f-filippi.com or contact our Sales network to check for any updates.

As 3F Filippi S.p.A. are constantly striving to improve our products, we reserve the right to modify the contents of this publication and the technical specifications of products

contained herein without prior notice.

3F Zeta

Fly2

Lucequadro

L 400

3F Linux

3F Petra

P 200

Galassia

L 450

Binario 3F

3F Drop

Zero 3F

3F Dodeca

L 560

3F Rocket

Mira

3F Quadro

L 320

L 580

3F Fil

3F Canda

Barraluce P

L 350 L 350 Fluo R90 L 390

L 590 Barraluce L

3F Travetta Filigare

Page 8

Page 88

Page 126

Page 198

Page 240

Page 16

Page 98

Page 134

Page 204

Page 262

Page 26

Page 108

Page 140

Page 208

Page 270

Page 28

Page 112

Page 154

Page 216

Page 275

Page 34

Page 114

Page 184 Page 190 Page 192

Page 224 Page 228

Page 42 Page 65

Page 4: 3F Filippi  "General catalogue 2016"

New

New

New

New New

3F1

Waterproof and corrosion-proof

Specific applications

Healthcare applications

Infopoint

Light Management

Product range

3F LEM

3F 66

3F Relax

3F Easy Dim

3F LED Technology Mechanics

Beta 4303F Linda

3F FS

LUCECURA

3F Smart Dimming

Lighting engineering Analytical guide

3F CubBeta A3F - i3F

3F Metro

3Fine Germicide

3F HCL

Electrical engineering

and Electronics

Page 284

Page 392

Page 404

Page 370Page 304

Page 394

Page 406

Page 378Page 338

Page 396

Page 408

3F Sensor 3F & KNX 3F CLO

Page 414

Page 436 Page 467

Page 420

Page 446 Page 471

Page 428

Page 460

Page 432 Page 433Page 418

Page 398

Page 5: 3F Filippi  "General catalogue 2016"

2

3F Filippi, the company

3F Filippi

3F Filippi S.p.A. has been active in the lighting engineering field for more than 60 years, with extensive experience in the design and manufacture of technically efficient lighting systems.

An ISO 9001-certified company for technical lighting design, we work together with the best technical lighting designers to provide our customers with quality lighting in line with the latest regulations and which guarantees the best performance, especially in the industrial, commercial and service sectors, also providing customised solutions.

Headquarters in Via Garganelli, Pian di Macina (Bologna, Italy)

Main Headquarters - Via del Savena Plant, Pian di Macina (Bologna, Italy)

Page 6: 3F Filippi  "General catalogue 2016"

3Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F Filippi, the company

In the 1990s the Dogana delle Filigare customs outpost, known in antiquity as the commercial outpost of the Grand Duke of Tuscany, was purchased. 3F Filippi restored it completely, making it a meeting place to present new lighting products to architects, project managers and designers and organise conventions and training courses.

Convention Centre - Dogana delle Filigare in Firenzuola (near Florence, Italy)

3F Filippi operates in more than 50 countries, through a sales network composed of regional and foreign offices: in addition to having our own regional branches and subsidiaries in Italy, the company also markets its products in Europe, Latin America, Asia and Oceania. Facilities also include warehouses for the storage of raw materials, semi-finished and finished products, allowing for optimised delivery times and shipping of equipment to customer depots, using the fleet of company vehicles.

Page 7: 3F Filippi  "General catalogue 2016"

4

Industrial

Hospitals

Common areas

Transport

Offices

Commerce

We bring the highest quality to lightWe have been giving our best in our work each day since 1952

We illuminate your world

3F Filippi lights different locations in innovative ways.Our products bring light to passengers on trains and underground railways, patients in hospitals, customers in shops and malls and workers in offices and banks. 3F Filippi helps some of the most prestigious manufacturers show off their products and some of the most important museums and art galleries in Europe light their treasures.

Wherever they are installed, 3F Filippi products always guarantee the highest quality and performance standards.

For 3F Filippi, the right product comes about above all by comparing and carefully analysing customer tastes and requirements: for this reason we focus on attention to detail and quality materials to create lighting with a technical spirit which is able to make the most of all it illuminates. Our products are made with a craftsman's passion, constant innovation and attention to detail in their design: they combine form and function, experience with new technology, ease of maintenance and reliability with excellent value for money.All 3F Filippi's products – produced internally, thus reducing transport – are made at our Pian di Macina plant: from the moulding of plastic and metal parts to machining of profile sections and automatic welding, completely automated painting and assembly. The thoroughness and precision of our checks guarantee constant quality for all our products over time.

Page 8: 3F Filippi  "General catalogue 2016"

5Datasheets, product updates and specifications on our website: www.3f-filippi.com

We bring the highest quality to light

We Protect your Light

The desire to preserve environmental resources has led 3F Filippi to collaborate with the best lighting designers to research and develop new solutions for high-quality, high-efficiency lighting.This research is performed using the highest quality materials and industrial processes which provide longer lifespans, components which comply with the latest standards and legislation, and intelligent wiring to maximise savings.

3F Filippi works with LightingEurope to develop increasingly advanced products which meet European and worldwide standards.

A supporting member of the GreenLight Programme (launched by the European Commission in order to reduce energy consumption), 3F Filippi carries out education campaigns to improve lighting efficiency in public and private industrial applications.

3F Filippi is an ISO 9001-certified company.

Photometric tests are performed by internal laboratories to satisfy EN 13032 and CIE 121 standards.Our flow recuperators are developed with the use of custom software which allows us to obtain maximum efficiency and light distribution which best meets the customer's needs.

This commitment has been recognised and certified by CSQ (Italian Certification of Company Quality Systems), also as regards the entire lighting engineering process.

Moreover, 3F Filippi is a member of ASSIL (National Association of Lighting Manufacturers), and a partner and supporter of IES (Illuminating Engineering Society of North America) and AIDI (Italian Lighting Association).

Quality in the Spotlight

Light for Projects

Can a luminaire contain high-quality components, be well designed and built to quality standards which meet the most stringent European and international safety, operational and sustainability standards? Yes, as long as it is made by 3F Filippi!

Our product lines cover a wide range of interior and exterior applications: from compact decorative, suspended and recessed luminaires to lighting systems for specific applications for hospitals or rail tunnels.High-efficiency flow recuperators and louvres, dimmable electronic wiring, made-to-measure luminaires for electronic ballasts and efficient sources – all these components maximise energy savings and provide optimum visual comfort, also in combination with light or presence sensors.

Page 9: 3F Filippi  "General catalogue 2016"
Page 10: 3F Filippi  "General catalogue 2016"

7

Surf

ace lum

inaires

and

susp

ensio

ns

News and updates available on: www.3f-filippi.com > Products > Surface luminaires and suspensions

Surface luminaires and Suspensions

8 3F Zeta8 New 3F Zeta L LED • • •

10 New 3F Zeta D LED • • •

12 New 3F Zeta DR LED • • •

16 3F Petra16 3F Petra LED LED • •

18 3F Petra LED Sensor LED • •

20 3F Petra Fluo Fluo • •

24 3F Petra Suspended Fluo Fluo •

26 3F Drop26 3F Drop LED •

28 Mira28 Mira Wall LED LED •

30 Mira Wall Fluo Fluo •

34 3F Canda34 3F Canda Quadrato LED LED • •

36 3F Canda Fluo Fluo • •

42 3F Travetta42 3F Travetta LED LED • •

46 New 3F Travetta LED DI LED •

48 New 3F Travetta LED HCL LED • •

50 3F Travetta Fluo Fluo • •

56 3F Travetta DI Fluo Fluo •

65 Filigare66 New Filigare 180 LED LED • •

68 Filigare 180 Fluo Fluo • •

76 Filigare 220 Fluo Fluo • •

88 Fly288 Fly2 LED LED •

90 New Fly2 Free-standing LED LED •

92 Fly2 Fluo Fluo •

98 P 20098 P 200 LED LED •

102 P 200 Fluo Fluo •

106 P 200 Fluo IP54 Fluo •

114 Barraluce P114 Barraluce P LED LED • •

118 Barraluce P Opal Fluo Fluo • •

120 Barraluce P 2MG Fluo Fluo • •

108 Zero 3F108 Zero 3F LED LED •

110 Zero 3F Fluo Fluo •

112 3F Quadro112 New 3F Quadro LED LED • •

Page Product Source Ceiling Semirecessed Suspended Wall Floor

Page 11: 3F Filippi  "General catalogue 2016"

8

New

3F Zeta LLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide direct distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanized steel, painted in white polyester, obtained through rolling process.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Light unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.End caps in white polycarbonate.Stainless steel mounting brackets with anti-slip screws.

Electrical characteristicsElectronic wiring 230V-50/60Hz.

Dimensions

Applications

Environments: architectural, commercial, transit areas, cornices, boards.

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers or colour temperatures• housing and accessories in RAL colours• wiring: dimmable, emergency (605 mm

long versions excluded)

Accessories

Accessories on page 14.

H

A

L

Page 12: 3F Filippi  "General catalogue 2016"

9Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Zeta L

Code 10892

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10894 New 3F Zeta L 15 LED L605 17 2462 605x62x67

10893 New 3F Zeta L 30 LED L1194 34 4924 1194x62x67

10892 New 3F Zeta L 40 LED L1489 42 6155 1489x62x67

3F Zeta L

E=100%

Lenses for wide distribution, in transparent PMMA with external flat surface.

Page 13: 3F Filippi  "General catalogue 2016"

10

New

3F Zeta DLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanized steel, painted in white polyester, obtained through rolling process.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Light unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.Curved screen in self-extinguishing polycarbonate, UV stabilized, opal, with smooth outer surface.End caps in white polycarbonate.Stainless steel mounting brackets with anti-slip screws.

Electrical characteristicsElectronic wiring 230V-50/60Hz.

Dimensions

Applications

Environments: architectural, commercial, transit areas, cornices, large mirrors, boards.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers or colour temperatures• housing and accessories in different RAL

colours• wiring: dimmable, emergency (605 mm

long versions excluded)

Accessories

Accessories on page 14.

H

A

L

Page 14: 3F Filippi  "General catalogue 2016"

11Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Zeta D

Code 10873

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10872 New 3F Zeta D 1x9 LED L605 10 1172 605x62x81

10871 New 3F Zeta D 1x18 LED L1194 20 2345 1194x62x81

10875 New 3F Zeta D 2x9 LED L605 20 2345 605x62x81

10870 New 3F Zeta D 1x22 LED L1489 25 2929 1489x62x81

10874 New 3F Zeta D 2x18 LED L1194 40 4689 1194x62x81

10873 New 3F Zeta D 2x22 LED L1489 50 5859 1489x62x81

3F Zeta D

E=100%

Curved opal polycarbonate diffuser.

Page 15: 3F Filippi  "General catalogue 2016"

12

New

3F Zeta DRLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsSymmetric and asymmetric lighting distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanized steel, painted in white polyester, obtained through rolling process.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Light unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.Rectangular screen in self-extinguishing polycarbonate, UV stabilized, opal, with smooth outer surface.End caps in white polycarbonate.Stainless steel mounting brackets with anti-slip screws.

Electrical characteristicsElectronic wiring 230V-50/60Hz.

Dimensions

Applications

Environments: architectural, commercial, transit areas, cornices, large mirrors, boards.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers or colour temperatures• housing and accessories in different RAL

colours• wiring: dimmable, emergency (605 mm

long versions excluded)

Accessories

Accessories on page 14.

H

A

L

Page 16: 3F Filippi  "General catalogue 2016"

13Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Zeta DR AS

Code 10887

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10886 New 3F Zeta DR AS 1x30 LED L1489 34 3912 1489x62x81

10887 New 3F Zeta DR AS 2x22 LED L1489 50 6208 1489x62x81

E=100%

Rectangular opal polycarbonate diffuser.

3F Zeta DR

Code 10880

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10879 New 3F Zeta DR 1x9 LED L605 10 1175 605x62x81

10878 New 3F Zeta DR 1x18 LED L1194 20 2351 1194x62x81

10882 New 3F Zeta DR 2x9 LED L605 20 2351 605x62x81

10877 New 3F Zeta DR 1x22 LED L1489 25 2938 1489x62x81

10881 New 3F Zeta DR 2x18 LED L1194 40 4701 1194x62x81

10880 New 3F Zeta DR 2x22 LED L1489 50 5874 1489x62x81

3F Zeta DR

E=100%

Rectangular opal polycarbonate diffuser.

Page 17: 3F Filippi  "General catalogue 2016"

14

Caddy hook to create a point from which to suspend the system or the loads to false ceilings with visible profiles.

Code Item

A02562 Caddy for exposed profiles of 24 mm

To be installed on exposed profiles (width 24 mm) of false ceilings.We recommend reinforcing the false-ceiling fixing at the point where the Caddy is to be installed.Supplied complete with nut and washer.The suspension must be purchased separately.

Hook to suspended luminaires to a chain.

Code Item

A20452 New Stainless steel hook for chain

Accessories

3F Zeta

Suspensions with regulator, galvanized steel cable 1.5 mm diameter, load 15 kg.

Code Item

A0660 New Suspension with adjustment for 3F Zeta - 1m

A0661 New Suspension with adjustment for 3F Zeta - 2 m

A0662 New Suspension with adjustment for 3F Zeta - 3 m

A0663 New Suspension with adjustment for 3F Zeta - 4 m

A0664 New Suspension with adjustment for 3F Zeta - 5 m

A0665 New Suspension with adjustment for 3F Zeta - 6 m

Page 18: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 19: 3F Filippi  "General catalogue 2016"

16

3F Petra LEDLED luminaire for high energy efficiency systems and high visual comfort

Construction characteristics

Illuminotechnical characteristicsDiffuse distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in self-extinguishing V2 polycarbonate, UV stabilized, injection moulded, glazed.Ecologic anti-aging injected sealing gasket.Diffuser in opal PMMA, injection moulded.Gear-tray reflector unit in aluminium, painted in white polyester, fixed to the housing by quick-fastening steel devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in transparent polycarbonate, tamper-proof opening.

Electrical characteristicsElectronic wiring 230V-50/60Hz.Entry for power-supply cable at the top (by means of doublemembrane sealing grommet) or from the side after drilling.In compliance with EN 60598-1.

Dimensions

Applications

Environments: architectural, transit areas, lobbies or waiting rooms, stairwells.Environments where ceiling indirect lighting and direct lighting supply a visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Completely insect and dust proof.

Source characteristics

• Circular LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• wiring: dimmable, EP or ENP mantained emergency, 1hr duration, 24hrs recharge, for 380-620 version

Ø

H

Page 20: 3F Filippi  "General catalogue 2016"

17Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Petra LED

Code 34330

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

34229 3F Petra OP 300 12W LED 15 1569 300x120

34330 3F Petra OP 380 22W LED 25 2839 380x117

34407 3F Petra OP 620 50W LED 56 5843 620x134

3F Petra LED

E=100%

Page 21: 3F Filippi  "General catalogue 2016"

18

3F Petra LED SensorLED luminaire for high energy efficiency systems and high visual comfort

Construction characteristics

Illuminotechnical characteristicsDiffuse distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in self-extinguishing V2 polycarbonate, UV stabilized, injection moulded, glazed.Ecologic anti-aging injected sealing gasket.Diffuser in opal PMMA, injection moulded.Gear-tray reflector unit in aluminium, painted in white polyester, fixed to the housing by quick-fastening steel devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in transparent polycarbonate, tamper-proof opening.

Electrical characteristicsElectronic wiring 230V-50/60Hz.Entry for power-supply cable at the top (by means of doublemembrane sealing grommet) or from the side after drilling.Sensor mode: turns on and off depending on light level and presence of persons.Presence sensor installed inside luminaire.In compliance with EN 60598-1.

Dimensions

Applications

Environments: architectural, transit areas, lobbies or waiting rooms, stairwells.Environments where ceiling indirect lighting and direct lighting supply a visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Completely insect and dust proof.

Light Management

For more information on 3F Sensor technology, refer to the specific chapter in the “Light Management” section.

Source characteristics

• Circular LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• 3F Petra OP 620 50W Sensor

Ø

H

Page 22: 3F Filippi  "General catalogue 2016"

19Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Petra LED Sensor

Code 34334

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

34233 3F Petra OP 300 12W LED Sensor 15 1569 300x120

34334 3F Petra OP 380 22W LED Sensor 25 2839 380x117

3F Petra LED Sensor

E=100%

Page 23: 3F Filippi  "General catalogue 2016"

20

3F Petra FluoDiffused distribution luminaire

Construction characteristics

Illuminotechnical characteristicsDiffuse distribution.

Mechanical characteristicsHousing in self-extinguishing V2 polycarbonate, UV stabilized, injection moulded.Ecologic anti-aging injected sealing gasket.Diffuser injection moulded.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, tamper-proof opening.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EEI B2 low loss starter wiring, 230V-50Hz, power factor correction, fuse, 0.5 mm² heat resistant wire HT 90°C.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.Entry for power-supply cable at the top (by means of doublemembrane sealing grommet) or from the side after drilling.

Dimensions

Applications

Environments: transit areas, lobbies or waiting rooms.Environments where soft diffuse light is required for optimal visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.

Source characteristics

• T5-R circular or compact fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• fuse accessory (on page 472)• wiring: twin-circuit, class II, different

powers, version with E27 fitting for integrated compact electronic energysaving lamps

• emergency inhibition

Ø

H

Page 24: 3F Filippi  "General catalogue 2016"

21Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Petra Melo Fluo

Code 37928

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

35465 3F Petra ME OP 300 1x22 T5-R LD HF IP64 25 1800 300x120

37927 3F Petra ME OP 380 1x22 T5-R LD HF IP64 25 1800 380x117

37928 3F Petra ME OP 380 1x40 T5-R LD HF IP64 42 3300 380x117

E>60%

Pomegranate polycarbonate housing.Diffuser in opal PMMA.Snap-lock clips in transparent polycarbonate.

3F Petra Opal Fluo

Code 37970

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

37859 3F Petra OP 300 1x22 T5-R LD HF IP64 25 1800 300x120

37969 3F Petra OP 380 1x22 T5-R LD HF IP64 25 1800 380x117

37864 3F Petra OP 300 1x26 CD LD HF IP64 26 1800 300x120

37970 3F Petra OP 380 1x40 T5-R LD HF IP64 42 3300 380x117

37979 3F Petra OP 380 2x26 CD LD HF IP64 53 3600 380x117

37941 3F Petra OP 620 1x40+1x60T5-RLDHFDA IP65 107 8300 620x134

EP emergency, fuse - Lamps supplied

37884 3F Petra OP 300 1x22 T5-R LD HF EP IP64 25 1800 300x120

37989 3F Petra OP 380 1x22 T5-R LD HF EP IP64 25 1800 380x117

37889 3F Petra OP 300 1x26 CD LD HF EP IP64 26 1800 300x120

37990 3F Petra OP 380 1x40 T5-R LD HF EP IP64 42 3300 380x117

37999 3F Petra OP 380 2x26 CD LD HF EP IP64 53 3600 380x117

3F Petra Fluo

E>55%

Glazed polycarbonate housing.Diffuser in opal PMMA.Snap-lock clips in transparent polycarbonate.

Page 25: 3F Filippi  "General catalogue 2016"

22

3F Petra Transparent Fluo

Code 35811

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

35705 3F Petra Trasparente 300 1x26 CD LD HF 26 1800 300x120

35811 3F Petra Trasparente 380 1x40 T5-R LD HF 42 3300 380x117

35820 3F Petra Trasparente 380 2x26 CD LD HF 53 3600 380x117

34650 3F Petra Trasparente 620 4x26CD LD HF DA 106 7200 620x134

34653 3F Petra Tras.620 1x40+60 T5-R LD HF DA 107 8300 620x134

EP emergency, fuse - Lamps supplied

35730 3F Petra Trasparente 300 1x26 CD LD HF EP 26 1800 300x120

35831 3F Petra Trasp 380 1x40 T5-R LD HF EP 42 3300 380x117

35840 3F Petra Trasparente 380 2x26 CD LD HF EP 53 3600 380x117

34658 3F Petra Trasp 620 4x26 CD LD HF DA EP 106 7200 620x134

3F Petra Fluo

E>62%

Transparent polycarbonate housing.Diffuser in self-extinguishing V2 transparent polycarbonate, UV stabilised, with smooth outside.Stainless steel clips.

Page 26: 3F Filippi  "General catalogue 2016"

23Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Petra Grey Fluo

Code 35211

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

35103 3F Petra GR 300 1x13 CD LD HF 14 900 300x120

35104 3F Petra GR 300 1x18 CD LD HF 19 1200 300x120

35100 3F Petra GR 300 1x22 T5-R LD HF 25 1800 300x120

35105 3F Petra GR 300 1x26 CD LD HF 26 1800 300x120

35108 3F Petra GR 300 2x13 CD LD HF 27 1800 300x120

35205 3F Petra GR 380 1x32 LD HF 34 2250 380x117

35219 3F Petra GR 380 2x18 CD LD HF 37 2400 380x117

35211 3F Petra GR 380 1x40 T5-R LD HF 42 3300 380x117

35220 3F Petra GR 380 2x26 CD LD HF 53 3600 380x117

EP emergency, fuse - Lamps supplied

35125 3F Petra GR 300 1x22 T5-R LD HF EP 25 1800 300x120

35130 3F Petra GR 300 1x26 CD LD HF EP 26 1800 300x120

35207 3F Petra GR 380 1x32 LD HF EP 34 2250 380x117

35231 3F Petra GR 380 1x40 T5-R LD HF EP 42 3300 380x117

35240 3F Petra GR 380 2x26 CD LD HF EP 53 3600 380x117

Starter EEI B2, fuse - Lamps supplied

35050 3F Petra GR 300 1x22 LD 28 1250 300x120

3F Petra Fluo

E>58%

Grey polycarbonate housing.Diffuser in self-extinguishing V2 transparent polycarbonate, UV stabilised, with smooth outside.Grey polycarbonate clips.

Page 27: 3F Filippi  "General catalogue 2016"

24

3F Petra Suspended FluoSuspended luminaire high visual comfort

Construction characteristics

Illuminotechnical characteristicsDiffuse distribution.

Mechanical characteristicsHousing in glazed self-extinguishing V2 polycarbonate, UV stabilised, injection moulded.Ecologic anti-aging injected sealing gasket.Diffuser in opal PMMA, injection moulded.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in transparent polycarbonate, tamper-proof opening.Adjustable suspension with Rose in white polycarbonate, with stainless steel cables, 2 m long.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Twin-circuit.Entry for power-supply cable at the top by means of double-membrane sealing grommet, or side-entry after drilling.Transparent 5x1.5 mm² power-supply cable.In compliance with EN 60598-1.

Dimensions

Applications

Environments: transit areas, great halls.Environments where ceiling indirect lighting and direct lighting supply a visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Completely insect and dust proof.

Source characteristics

• T5-R circular fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• compact lamps• polycarbonate diffuser• fuse accessory (on page 472)• wiring: dimmable, class II

Ø

H

Page 28: 3F Filippi  "General catalogue 2016"

25Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Petra Suspended

Code 34345

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

34345 3F Petra OP 620 1x40+1x60 T5-R LDHFDA SO 107 8300 620x134

3F Petra Suspended Fluo

E>60%

Page 29: 3F Filippi  "General catalogue 2016"

26

3F DropLED pendant luminaire for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsCylindrical aluminum body painted bonderized RAL 9006 metallic gray.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Circular anti-glare LED shielding lens in transparent prismatic PMMA for good visual comfort.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: commercial, exhibition areas, for food service, transit areas, lobbies or waiting rooms, corridors, halls, shops, display windows.

Source characteristics

Compact LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.Color initial tolerance (MacAdam): 3.Zhaga Book 3 compliant.

On request

• LED module, CCT nominal color temperature 3000 K, color rendering index CRI >90

• housing in RAL colour• wiring: dimmable

Accessories

Accessories (always necessary) on page 27.

Ø

H

Page 30: 3F Filippi  "General catalogue 2016"

27Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Drop

Code 37507

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37507 3F Drop LED GR 3000 27.5 2471 150x228

3F Drop

E=100%

Accessories

Suspension (always needed) composed by: polycarbonate ceiling white rose Ø 110 mm, stainless steel cable Ø 1,25 mm (length 1 m), quick adjuster, transparent power cable 3x1,5 mm² (length 2 m).

Code Item

A01457 Susp with Rose 110 Adj 1m Cable 2m

Page 31: 3F Filippi  "General catalogue 2016"

28

Mira Wall LEDLED luminaire wall energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsAsymmetric indirect distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted steel.Flow recuperator in specular aluminium with superficial titanium-magnesium treatment.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: with VDTs, meeting rooms, offices.Environments: transit areas, lobbies or waiting rooms, corridors, stairwells.Environments where soft diffuse light is required for optimal visual comfort.

Installation

Wall installation.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• housing in RAL colour• wiring: dimmable

Accessories

Accessories on page 32.

L

H

A

L

Page 32: 3F Filippi  "General catalogue 2016"

29Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Mira Par LED DEC

Code 1961

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

1961 Mira Par LED DE 4x12W L675 56 6493 675x230x80

E=100%

Direct and indirect decorative lighting.Body with reticular slots.Opal acrylic upper diffuser.Opal polycarbonate Inlay Cover for perforated housings.

Mira Par LED IND

Code 1959

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

1959 Mira Par LED 4x12W IND L675 56 6298 675x230x80

Mira Wall LED

E=100%

Indirect lighting.Upper closing diffuser in selfextinguishing V2 transparent polycarbonate, UV stabilized.

Page 33: 3F Filippi  "General catalogue 2016"

30

Mira Wall FluoLuminaire for wall installation

Construction characteristics

Illuminotechnical characteristicsIndirect asymmetric or high direct distribution.

Mechanical characteristicsHousing in white painted steel.Lower holes closing film made of opal polycarbonate.Flow recuperator in specular aluminium with superficial titanium-magnesium treatment.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

Dimensions

Applications

Environments: with VDTs, meeting rooms, offices.Environments: transit areas, lobbies or waiting rooms, corridors, stairwells.Environments where soft diffuse light is required for optimal visual comfort.

Installation

Wall installation.

Source characteristics

• 55W compact fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• housing in RAL colour• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 32.

L

H

A

Page 34: 3F Filippi  "General catalogue 2016"

31Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Mira Par Fluo DE

Code 1594

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

1597 Mira Par DE 2x14-24 T5 HF 31-49 2400-3500 675x230x80

1594 Mira Par DE 2x28-54 T5 HF 60-114 5200-8900 1235x230x80

1598 Mira Par DE 2x35-49-80 T5 HF 76-106-170 6600-8600-12300 1535x230x80

E>69%

Indirect E>44%

Direct E>25%

Body with reticular slots.Opal acrylic upper diffuser.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.

Mira Par Fluo

Code 1575

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps supplied

1575 Mira Par 1x55 C HF 60 4300 675x230x80

1576 Mira Par 2x55 C HF 118 8600 675x230x80

EEI A2 electronic wiring - Lamps not included

1577 Mira Par 1x36 HF 36 3350 1285x230x80

1578 Mira Par 1x58 HF 55 5200 1585x230x80

1580 Mira Par 2x36 HF 71 6700 1285x230x80

1581 Mira Par 2x58 HF 109 10400 1585x230x80

Mira Wall Fluo

E>76%

Indirect E>65%

Direct E>11%

Housing with microperforations.Upper closing diffuser in selfextinguishing V2 transparent polycarbonate, UV stabilized.

Page 35: 3F Filippi  "General catalogue 2016"

32

5-pole terminal block, connection capacity from 2.5 to 6 mm², on galvanized steel bracket for cascade connection lines.

Code Item

A0090 Bracket/5-pole terminal block

Accessories

Mira

Connecting element for variable interdistances between luminaires, composed of a pair of adapter cylinders and aluminium tube 1.5 m long, Ø35 mm, which can be sectioned to any desired length.

Code Item

A0034 Pair of white cylinders

A0035 Aluminium tube 1.5 m white

Page 36: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 37: 3F Filippi  "General catalogue 2016"

34

3F Canda Quadrato LEDCompact LED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsSingle-piece housing in pressed steel, painted white.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Ceiling mounting or semi-recessed installation.Environments where soft diffuse light is required for optimal visual comfort.2MG versionEnvironments: exhibition areas, staterooms, with VDTs, transit areas, halls, shops, great halls, offices.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• satin louvre• wiring: twin-circuit2x12W version• wiring: dimmable, emergency (wiring

unit outside the luminaire)

Accessories

Accessories on page 39.

H

2 x 8W 2 x 12W

A = L A = L

Page 38: 3F Filippi  "General catalogue 2016"

35Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Canda Quadrato LED SP

Code 164736

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

164723 3F Canda LED 2x8W SP 300x300 17 1032 300x300x79

164736 3F Canda LED 2x12W SP 430x430 29.5 2781 430x430x79

E=100%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the flow recuperators.Flow recuperator in specular aluminium.

3F Canda Quadrato LED 2MG

Code 164732

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

164719 3F Canda LED 2x8W 2MG 300x300 17 1044 300x300x79

164732 3F Canda LED 2x12W 2MG 430x430 29.5 2814 430x430x79

3F Canda Quadrato LED

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 39: 3F Filippi  "General catalogue 2016"

36

3F Canda FluoHigh visual comfort luminaire

Construction characteristics

Illuminotechnical characteristicsDirect or direct/indirect distribution.Average luminance <200 cd/m² for radial angles >65°.

Mechanical characteristicsSingle-piece housing in pressed steel, painted white.Parabolic louvres with transverse blades closed at the top.Film protective against dust and finger marks, attached to louvre.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.1-10V EEI A1 dimmable electronic wiring, 230V-50/60Hz.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Environments: exhibition areas, staterooms, with VDTs, transit areas, halls, shops, great halls, offices.Environments where soft diffuse light is required for optimal visual comfort.

Source characteristics

T5 fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• housing and accessories in RAL colour• fuse accessory (on page 472)• wiring: twin-circuit, dimmable,

emergency, 1hr duration, 12hrs recharge• emergency inhibition

Accessories

Accessories on page 39.

H

A

L

Page 40: 3F Filippi  "General catalogue 2016"

37Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Canda 2MG

Code 166029

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

166027 3F Canda 2x28 T5 HF 2MG 60 5200 1300x260x77

166029 3F Canda 2x35 T5 HF 2MG 76 6600 1600x260x77

Dimmable electronic EEI A1 - Pre-mounted lamps

166055 3F Canda 2x28 T5 HF D1-10V 2MG 60 5200 1300x260x77

166057 3F Canda 2x35 T5 HF D1-10V 2MG 75 6600 1600x260x77

EP emergency, fuse - Pre-mounted lamps

166041 3F Canda 2x28 T5 HF EP 2MG 60 5200 1300x260x77

166043 3F Canda 2x35 T5 HF EP 2MG 75 6600 1600x260x77

3F Canda Fluo

L<200 cd/m² 65°

E>71%

2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.Direct distribution.

Page 41: 3F Filippi  "General catalogue 2016"

38

3F Canda DI 2MG

Code 167329

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

167327 3F Canda DI 2x28 T5 HF 2MG 60 5200 1300x260x77

167329 3F Canda DI 2x35 T5 HF 2MG 76 6600 1600x260x77

Dimmable electronic EEI A1 - Pre-mounted lamps

167355 3F Canda DI 2x28 T5 HF D1-10V 2MG 60 5200 1300x260x77

167357 3F Canda DI 2x35 T5 HF D1-10V 2MG 75 6600 1600x260x77

EP emergency, fuse - Pre-mounted lamps

167341 3F Canda DI 2x28 T5 HF EP 2MG 60 5200 1300x260x77

167343 3F Canda DI 2x35 T5 HF EP 2MG 75 6600 1600x260x77

3F Canda Fluo

L<200 cd/m² 65°

E>90%

Indirect E>37%

Direct E>53%

2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.Direct-indirect distribution.

Page 42: 3F Filippi  "General catalogue 2016"

39Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Adjustable suspension with polycarbonate case, white colour, internal bracket in galvanized steel.Stainless steel cables Ø 1.25 mm, 1 m long leaded at the end and adjusters for coupling on the luminaire and on connecting element.Wired version with white linear power supply cable, H05VV-F 4x1.5 mm².

Code Item

A0618 Adjustable suspension with case 1 m

A0619 Wired adjustable suspension with case 1 m

Fixed suspension with polycarbonate case, white colour, internal bracket in galvanized steel, stainless steel cables Ø1,25 mm leaded at the end for coupling on the luminaire (not on connecting element).Wired version with white power-supply linear cable type H05VV-F 4x1.5 mm².Length of the suspension from the ceiling to the centre of the luminaire.

Code Item

A0610 Fixed suspension with case 0.3 m

A0611 Fixed suspension with case 0.5 m

A0612 Fixed suspension with case 0.8 m

A0613 Fixed suspension with case 1 m

A0614 Wired fixed suspension with case 0.3 m

A0615 Wired fixed suspension with case 0.5 m

A0616 Wired fixed suspension with case 0.8 m

A0617 Wired fixed suspension with case 1 m

Connecting element to form channels and branches, in white painted steel with upper holes for suspensions or wall brackets. It allows the passage of the power-supply line. Polycarbonate cover. It spaces the luminaires by 40 mm.

Code Item

A0601 White linear connecting element 40 mm

A0602 White linear connecting element 200 mm

A0603 White linear connecting element 500 mm

A0604 White linear connecting element 1100 mm

A0605 White joint 3F Canda/wall 600 mm

A0606 White joint 3F Canda/wall 1100 mm

Accessories

3F Canda

Bracket, for semi-recessed installation of 3F Canda Quadrato for false ceilings with panels 600x600, 600x1200 with exposed structure or plasterboard, in hot-galvanized steel.

Code Item

A0645 Semi-recessed bracket (3F Canda Quadrato)

Page 43: 3F Filippi  "General catalogue 2016"

40

5-pole cascade connection line, stiff cable H07V2-U, HT 90°C, 1.5 mm², terminal blocks with connection capacity 2x2.5 mm².

Code Item

A0634 Casc. conn. Line 5x1.5 3F Canda 1300

A0635 Casc. conn. Line 5x1.5 3F Canda 1600

Pair of wall-mounting elements, in white painted steel and white polycarbonate cover, spaces the luminaires of 28 mm from the wall.Mounting on the side of the housing and on the connecting element.

Code Item

A0631 Pair of white wall-mounting brackets 3F Canda

Only for linear luminaires, not compact.

Bracket sliding on the housing, in white painted steel, for free positioning of mounting at the ceiling or suspended: suspensions are always necessary.

Code Item

A0629 White sliding bracket 3F Canda

Spacers for reflected light luminaires, space 3F Canda linear luminaires of 60 mm from the ceiling.Realized in polycarbonate, white colour, with bracket in galvanized steel, white power-supply cable type H05VV-F 4x1.5 mm².

Code Item

A0623 Pair of spacers 3F Canda 60 mm ceiling

To be fixed directly on the luminaire at 600 mm centre distance.Installation also possible on false ceilings with exposed profile.Two spacers each luminaire are always necessary, even for channel installations.

Accessories

3F Canda

Electrical socket with white polycarbonate ceiling rose Ø 86 mm, white cable 4x1.5 mm², H05VV-F (length 2 m).

Code Item

A0130 Rose 86 (4-pole wired boss)

Page 44: 3F Filippi  "General catalogue 2016"

41Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

5-pole terminal block, connection capacity from 2.5 to 6 mm², on galvanized steel bracket for cascade connection lines.

Code Item

A0090 Bracket/5-pole terminal block

Accessories

3F Canda

White connecting element for variable distances between two luminaries (A0607) or between the luminarie and the wall (use A0609), which is ALWAYS coupled to the tube (A0608) sectioned to any desired length and which allows the passage of the power line.

Code Item

A0607 Pair of white cylinders 3F Canda

A0608 White Alluminium Tube Ø.20 mm 1,5 m

A0609 White wall-mounting boss 3F Canda

Page 45: 3F Filippi  "General catalogue 2016"

42

3F Travetta LEDLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing with squared shape in white painted steel, with nonreflecting surface.

Electrical characteristicsElectronic wiring 230V-50/60Hz.5-pole terminal block for cascade line connection with connection capacity 2x2.5 mm².In compliance with EN 60598-1.

Dimensions

Applications

Environments: exhibition areas, staterooms, with VDTs, halls, shops, great halls, offices.Environments where soft diffuse light is required for optimal visual comfort.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers or colour temperatures• different dimensions• housing and accessories in RAL colours• wiring: dimmable, emergency• version with integrated presence and

light sensor

Accessories

Accessories on page 60.

A

H

H

L

Page 46: 3F Filippi  "General catalogue 2016"

43Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta LED Opal

Code 10735

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10732 3F Travetta LED 1x22W OP L1590 25 2744 1590x190x60

10775 New 3F Travetta LED 1x40W OP L2200 44 4608 2200x190x60

10735 3F Travetta LED 2x22W OP L1590 50 5340 1590x190x60

10777 New 3F Travetta LED 2x40W OP L2200 88 8970 2200x190x60

E=100%

OP opal methacrylate flat diffuser, anti-glare.Flow recuperator in semi-specular aluminium, high efficiency.

3F Travetta LED 2MG

Code 10707

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10704 3F Travetta LED 1x22W 2MG L1590 25 3001 1590x190x60

10707 3F Travetta LED 2x22W 2MG L1590 50 5813 1590x190x60

3F Travetta LED

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 47: 3F Filippi  "General catalogue 2016"

44

3F Travetta LED SP

Code 10721

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10718 3F Travetta LED 1x22W SP L1590 25 2945 1590x190x60

10771 New 3F Travetta LED 1x40W SP L2200 44 4947 2200x190x60

10721 3F Travetta LED 2x22W SP L1590 50 5743 1590x190x60

10773 New 3F Travetta LED 2x40W SP L2200 88 9648 2200x190x60

3F Travetta LED

E=100%

1x - Average luminance <3000 cd/m² for radial angles >65°.SP flat diffuser in PMMA transparent prismatic methacrylate, anti-glare.Flow recuperator in semi-specular aluminium, high efficiency.

Page 48: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 49: 3F Filippi  "General catalogue 2016"

46

New

3F Travetta LED DILED pendant luminaire for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsDirect-indirect distribution.Average luminance <1000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing with squared shape in white painted steel, with nonreflecting surface.Upper holes closing film made of opal polycarbonate.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.5-pole terminal block for cascade line connection with connection capacity 2x2.5 mm².

Dimensions

Applications

Environments: exhibition areas, staterooms, with VDTs, halls, shops, great halls, offices.Environments where soft diffuse light is required for optimal visual comfort.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers or colour temperatures• different dimensions• housing and accessories in RAL colours• wiring: dimmable, emergency• version with integrated presence and

light sensor

Accessories

Accessories on page 60.

A

H

H

L

Page 50: 3F Filippi  "General catalogue 2016"

47Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta LED DI 2MG

Code 10748

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

10747 New 3F Travetta LED DI 2x15W 2MG L1590 34 3694 1590x190x60

10748 New 3F Travetta LED DI 2x22W 2MG L1590 50 5455 1590x190x60

3F Travetta LED DI

L<1000 cd/m² 65°

E=100%

Indirect E>19%

Direct E>81%

2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 51: 3F Filippi  "General catalogue 2016"

48

New

3F Travetta LED HCLWellbeing LED fixture

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Average luminance <1000 cd/m² for radial angles >65°.The color temperature can be adjusted between 2700 K and 6500 K.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing with squared shape in white painted steel, with nonreflecting surface.

Electrical characteristicsDALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.5-pole terminal block for cascade line connection with connection capacity 2x2.5 mm².

Dimensions

Applications

Any environments requiring light which aims for the wellness of people.Environments with VDTs.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Light Management

In this product the light intensity and color temperature can be controlled automatically or manually, with the “Controller HCL” (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature from 2700 K to 6500 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different dimensions• housing and accessories in RAL colours• wiring: emergency

Accessories

Accessories on page 60.

A

H

H

L

Page 52: 3F Filippi  "General catalogue 2016"

49Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta LED HCL

Code 10763

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

10763 New 3F Travetta LED 2x22W DALI HCL 2MG L1590 50 5813 1590x190x60

3F Travetta LED HCL

L<1000 cd/m² 65°

E=100%

Variable light intensity and color temperature.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Opal methacrylate diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 53: 3F Filippi  "General catalogue 2016"

50

3F Travetta FluoLuminaire with direct light distribution

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution, asymmetric lighting distribution can be achieved in the singlelamp versions by offsetting the lamp.

Mechanical characteristicsHousing with squared shape in white or grey RAL 9006 (GR) painted steel, with non-reflecting surface.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.DALI MultiWatt EEI A1 electronic wiring, 230V-50/60Hz, lamp warm start.5-pole terminal block for cascade line connection with connection capacity 2x2.5 mm².

Dimensions

Applications

Environments: exhibition areas, staterooms, with VDTs, halls, shops, great halls, offices.Environments where soft diffuse light is required for optimal visual comfort.2MG WIDE versionLow-ceiling environments or where requirements can change.

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• T5 fluorescent lamps, mounted (except for Multiwatt series), CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• lamps in different powers or colour temperatures

• housing and accessories in RAL colour• prismatic transparent flat diffuser• fuse accessory (on page 472)• wiring: dimmable, MultiWatt electronic,

twin-circuit, emergency• emergency inhibition

Accessories

Accessories on page 60.

A

H

H

L

Page 54: 3F Filippi  "General catalogue 2016"

51Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta 2MG

Code 13261

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

13255 3F Travetta 1x14 T5 LD HF 2MG 16 1200 690x190x60

13258 3F Travetta 1x24 T5 LD HF 2MG 25 1750 690x190x60

13262 3F Travetta 2x14 T5 LD HF 2MG 31 2400 690x190x60

13257 3F Travetta 1x35 T5 LD HF 2MG 38 3300 1590x190x60

13265 3F Travetta 2x24 T5 LD HF 2MG 49 3500 690x190x60

13260 3F Travetta 1x49 T5 LD HF 2MG 53 4300 1590x190x60

13259 3F Travetta 1x54 T5 LD HF 2MG 58 4450 1290x190x60

13263 3F Travetta 2x28 T5 LD HF 2MG 60 5200 1290x190x60

13261 3F Travetta 1x80 T5 LD HF 2MG 86 6150 1590x190x60

13264 3F Travetta 2x35 T5 LD HF 2MG 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

13085 3F Travetta GR 1x14 T5 LD HF 2MG 16 1200 690x190x60

13088 3F Travetta GR 1x24 T5 LD HF 2MG 25 1750 690x190x60

13092 3F Travetta GR 2x14 T5 LD HF 2MG 31 2400 690x190x60

13087 3F Travetta GR 1x35 T5 LD HF 2MG 38 3300 1590x190x60

13095 3F Travetta GR 2x24 T5 LD HF 2MG 49 3500 690x190x60

13090 3F Travetta GR 1x49 T5 LD HF 2MG 53 4300 1590x190x60

13089 3F Travetta GR 1x54 T5 LD HF 2MG 58 4450 1290x190x60

13093 3F Travetta GR 2x28 T5 LD HF 2MG 60 5200 1290x190x60

13091 3F Travetta GR 1x80 T5 LD HF 2MG 86 6150 1590x190x60

13094 3F Travetta GR 2x35 T5 LD HF 2MG 76 6600 1590x190x60

3F Travetta Fluo

L<1000 cd/m² 65°

E>68%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 55: 3F Filippi  "General catalogue 2016"

52

3F Travetta DALI 2MG WIDE

Code 14878

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - DALI EEI A1 electronic Multiwatt - Lamps not included

14877 3F Travetta 1x28-54 T5 HF DALI 2MG AMPIA 31-58 2600-4450 1290x190x60

14878 3F Travetta 1x35-49-80 T5 HF DALI 2MG AM 38-53-86 3300-4300-6150 1590x190x60

14879 3F Travetta 2x28-54 T5 HF DALI 2MG AMPIA 60-114 5200-8900 1290x190x60

14880 3F Travetta 2x35-49-80 T5 HF DALI 2MG AM 76-106-170 6600-8600-12300 1590x190x60

L<1000 cd/m² 65°

E>74%

Average luminance <1000 cd/m² for radial angles >65°.Direct wide distribution to optimize lighting uniformity with wide installation distances among luminaires in environments with low ceilings.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

3F Travetta 2MG WIDE

Code 13163

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Grey housing - Electronic MultiWatt EEI A2 - Lamps not included

13162 3F Travetta GR 1x28-54 T5 HF 2MG AMPIA 31-58 2600-4450 1290x190x60

13163 3F Travetta GR 1x35-49-80 T5 HF 2MG AMPIA 38-53-86 3300-4300-6150 1590x190x60

13165 3F Travetta GR 2x28-54 T5 HF 2MG AMPIA 60-114 5200-8900 1290x190x60

13166 3F Travetta GR 2x35-49 T5 HF 2MG AMPIA 76-106 6600-8600 1590x190x60

3F Travetta Fluo

L<1000 cd/m² 65°

E>74%

Average luminance <1000 cd/m² for radial angles >65°.Direct wide distribution to optimize lighting uniformity with wide installation distances among luminaires in environments with low ceilings.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 56: 3F Filippi  "General catalogue 2016"

53Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta 2S

Code 13604

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

13595 3F Travetta 1x14 T5 LD HF 2S 16 1200 690x190x60

13598 3F Travetta 1x24 T5 LD HF 2S 25 1750 690x190x60

13602 3F Travetta 2x14 T5 LD HF 2S 31 2400 690x190x60

13597 3F Travetta 1x35 T5 LD HF 2S 38 3300 1590x190x60

13605 3F Travetta 2x24 T5 LD HF 2S 49 3500 690x190x60

13600 3F Travetta 1x49 T5 LD HF 2S 53 4300 1590x190x60

13599 3F Travetta 1x54 T5 LD HF 2S 58 4450 1290x190x60

13603 3F Travetta 2x28 T5 LD HF 2S 60 5200 1290x190x60

13601 3F Travetta 1x80 T5 LD HF 2S 86 6150 1590x190x60

13604 3F Travetta 2x35 T5 LD HF 2S 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

13425 3F Travetta GR 1x14 T5 LD HF 2S 16 1200 690x190x60

13428 3F Travetta GR 1x24 T5 LD HF 2S 25 1750 690x190x60

13432 3F Travetta GR 2x14 T5 LD HF 2S 31 2400 690x190x60

13427 3F Travetta GR 1x35 T5 LD HF 2S 38 3300 1590x190x60

13435 3F Travetta GR 2x24 T5 LD HF 2S 49 3500 690x190x60

13430 3F Travetta GR 1x49 T5 LD HF 2S 53 4300 1590x190x60

13429 3F Travetta GR 1x54 T5 LD HF 2S 58 4450 1290x190x60

13433 3F Travetta GR 2x28 T5 LD HF 2S 60 5200 1290x190x60

13431 3F Travetta GR 1x80 T5 LD HF 2S 86 6150 1590x190x60

13434 3F Travetta GR 2x35 T5 LD HF 2S 76 6600 1590x190x60

3F Travetta Fluo

L<1000 cd/m² 65°

E>62%

Average luminance <1000 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 57: 3F Filippi  "General catalogue 2016"

54

3F Travetta Opal

Code 19090

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

19003 3F Travetta 1x35 T5 LD HF OP 38 3300 1290x190x60

19006 3F Travetta 1x49 T5 LD HF OP 53 4300 1290x190x60

19005 3F Travetta 1x54 T5 LD HF OP 58 4450 1590x190x60

19009 3F Travetta 2x28 T5 LD HF OP 60 5200 1590x190x60

19010 3F Travetta 2x35 T5 LD HF OP 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

19088 3F Travetta GR 1x35 T5 LD HF OP 38 3300 1290x190x60

19091 3F Travetta GR 1x49 T5 LD HF OP 53 4300 1290x190x60

19090 3F Travetta GR 1x54 T5 LD HF OP 58 4450 1590x190x60

19094 3F Travetta GR 2x28 T5 LD HF OP 60 5200 1590x190x60

19095 3F Travetta GR 2x35 T5 LD HF OP 76 6600 1590x190x60

3F Travetta Fluo

E>57%

OP opal methacrylate flat diffuser, anti-glare.Flow recuperator in semi-specular aluminium, high efficiency.

Page 58: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 59: 3F Filippi  "General catalogue 2016"

56

3F Travetta DI FluoSuspension luminaire with direct and indirect light distribution

Construction characteristics

Illuminotechnical characteristicsDirect-indirect symmetric distribution, asymmetric lighting distribution can be achieved in the singlelamp versions by offsetting the lamp.

Mechanical characteristicsHousing with squared shape in white or grey RAL 9006 (GR) painted steel, with non-reflecting surface.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.DALI MultiWatt EEI A1 electronic wiring, 230V-50/60Hz, lamp warm start.5-pole terminal block for cascade line connection with connection capacity 2x2.5 mm².

Dimensions

Applications

Environments: exhibition areas, staterooms, with VDTs, halls, shops, great halls, offices.Environments where soft diffuse light is required for optimal visual comfort.2MG WIDE versionLow-ceiling environments or where requirements can change.

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• T5 fluorescent lamps, mounted (except for Multiwatt series), CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• different powers or colour temperatures• housing and accessories in RAL colours• lower flat diffuser in transparent PMMA,

prismatic• fuse accessory (on page 472)• wiring: dimmable, MultiWatt electronic,

twin-circuit, emergency• emergency inhibition

Accessories

Accessories on page 60.

A

H

H

L

Page 60: 3F Filippi  "General catalogue 2016"

57Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta DI 2MG WIDE

Code 13078

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Grey housing - Electronic MultiWatt EEI A2 - Lamps not included

13077 3F Travetta GR DI 1x28-54 T5 HF 2MG AMPIA 31-58 2600-4450 1290x190x60

13078 3F Travetta GR DI 1x35-49-80T5 HF 2MG AM 38-53-86 3300-4300-6150 1590x190x60

13080 3F Travetta GR DI 2x28-54 T5 HF 2MG AMPIA 60-114 5200-8900 1290x190x60

13081 3F Travetta GR DI 2x35-49 T5 HF 2MG AMPIA 76-106 6600-8600 1590x190x60

L<1000 cd/m² 65°

E>81%

Average luminance <1000 cd/m² for radial angles >65°.Wide distribution to optimize lighting uniformity with wide installation distances among luminaires in environments with low ceilings.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

3F Travetta DI 2MG

Code 13174

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

13172 3F Travetta DI 1x35 T5 LD HF 2MG 38 3300 1590x190x60

13175 3F Travetta DI 1x49 T5 LD HF 2MG 53 4300 1590x190x60

13174 3F Travetta DI 1x54 T5 LD HF 2MG 58 4450 1290x190x60

13178 3F Travetta DI 2x28 T5 LD HF 2MG 60 5200 1290x190x60

13179 3F Travetta DI 2x35 T5 LD HF 2MG 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

13002 3F Travetta GR DI 1x35 T5 LD HF 2MG 38 3300 1590x190x60

13005 3F Travetta GR DI 1x49 T5 LD HF 2MG 53 4300 1590x190x60

13004 3F Travetta GR DI 1x54 T5 LD HF 2MG 58 4450 1290x190x60

13008 3F Travetta GR DI 2x28 T5 LD HF 2MG 60 5200 1290x190x60

13009 3F Travetta GR DI 2x35 T5 LD HF 2MG 76 6600 1590x190x60

3F Travetta DI Fluo

L<1000 cd/m² 65°

E>87%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 61: 3F Filippi  "General catalogue 2016"

58

3F Travetta DI 2S

Code 13514

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

13512 3F Travetta DI 1x35 T5 LD HF 2S 38 3300 1590x190x60

13515 3F Travetta DI 1x49 T5 LD HF 2S 53 4300 1590x190x60

13514 3F Travetta DI 1x54 T5 LD HF 2S 58 4450 1290x190x60

13518 3F Travetta DI 2x28 T5 LD HF 2S 60 5200 1290x190x60

13519 3F Travetta DI 2x35 T5 LD HF 2S 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

13342 3F Travetta GR DI 1x35 T5 LD HF 2S 38 3300 1590x190x60

13345 3F Travetta GR DI 1x49 T5 LD HF 2S 53 4300 1590x190x60

13344 3F Travetta GR DI 1x54 T5 LD HF 2S 58 4450 1290x190x60

13348 3F Travetta GR DI 2x28 T5 LD HF 2S 60 5200 1290x190x60

13349 3F Travetta GR DI 2x35 T5 LD HF 2S 76 6600 1590x190x60

L<1000 cd/m² 65°

E>78%

Average luminance <1000 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

3F Travetta DI DALI 2MG WIDE

Code 14923

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - DALI EEI A1 electronic Multiwatt - Lamps not included

14922 3F Travetta DI 1x28-54 T5 HF DALI 2MG AM 31-58 2600-4450 1290x190x60

14923 3F Trav. DI 1x35-49-80 T5 HF DALI 2MG AM 38-53-86 3300-4300-6150 1590x190x60

14924 3F Travetta DI 2x28-54 T5 HF DALI 2MG AM 60-114 5200-8900 1290x190x60

14925 3F Trav.DI 2x35-49-80 T5 HF DALI 2MG AM 76-106-170 6600-8600-12300 1590x190x60

3F Travetta DI Fluo

L<1000 cd/m² 65°

E>81%

Average luminance <1000 cd/m² for radial angles >65°.Wide distribution to optimize lighting uniformity with wide installation distances among luminaires in environments with low ceilings.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 62: 3F Filippi  "General catalogue 2016"

59Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Travetta DI Opal

Code 19175

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

19173 3F Travetta DI 1x35 T5 LD HF OP 38 3300 1590x190x60

19176 3F Travetta DI 1x49 T5 LD HF OP 53 4300 1590x190x60

19175 3F Travetta DI 1x54 T5 LD HF OP 58 4450 1290x190x60

19179 3F Travetta DI 2x28 T5 LD HF OP 60 5200 1290x190x60

19180 3F Travetta DI 2x35 T5 LD HF OP 76 6600 1590x190x60

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

19258 3F Travetta GR DI 1x35 T5 LD HF OP 38 3300 1590x190x60

19261 3F Travetta GR DI 1x49 T5 LD HF OP 53 4300 1590x190x60

19260 3F Travetta GR DI 1x54 T5 LD HF OP 58 4450 1290x190x60

19264 3F Travetta GR DI 2x28 T5 LD HF OP 60 5200 1290x190x60

19265 3F Travetta GR DI 2x35 T5 LD HF OP 76 6600 1590x190x60

3F Travetta DI Fluo

E>69%

OP lower flat diffuser in opal PMMA methacrylate, upper in opal polycarbonate.Flow recuperator in semi-specular aluminium, high efficiency.

Page 63: 3F Filippi  "General catalogue 2016"

60

Linear connecting element and for branch, between luminaires or between luminaires and wall, to form channels, in steel with accessorizable cover, white or grey RAL 9006 colour.It allows the passage of the power-supply line.Concerning the use of connecting elements in false ceilings 600x600, see installation.

Code Item

A0880 Connecting element 190x190 3F Travetta GR

A0882 Connecting element 190x210 3F Travetta GR

A0883 Connecting element 190x510 3F Travetta GR

A0884 Connecting element 190x810 3F Travetta GR

A0885 Connecting element 190x1110 3F Travetta GR

A0892 White connecting element 190x190 3F Travetta GR

A0894 White connecting element 190x210 3F Travetta GR

A0895 White connecting element 190x510 3F Travetta GR

A0896 White connecting element 190x810 3F Travetta GR

A0897 White connecting element 190x1110 3F Travetta GR

A0937 Connecting element lum/wall 810 3F Travetta GR

A0938 Connecting element lum/wall 1110 3F Travetta GR

A0941 White connecting element lum/wall 810 3F Travetta

A0942 White connecting element lum/wall 1110 3F Travetta

On request: Elements of desired length. Connecting elements for false ceiling 625x625.

Accessories

3F Travetta

Connecting bracket to form linear channels or branches of single luminaires, in galvanized steel with upper holes for adjustable suspensions.

Code Item

A0875 Connecting bracket for linear channels or branches

Page 64: 3F Filippi  "General catalogue 2016"

61Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Adjustable suspension with polycarbonate case in white colour, internal bracket in galvanized steel.Wired version with transparent power cable 5x1.5 mm².Stainless steel cables, length 1 m, leaded at one end with adjusters for coupling on the luminaire.

Code Item

A01318 White rectangular case suspension-adj. 1 m

A01325 Wired suspension 5P white rectangular case-adj.1 m

On request:for suspensions longer than 1 m, it is necessary not only to order codes 01318-01325 but also stainless steel cables in spool of 100 m and pack of n° 100 clamps.

Linear connecting element end cap to be used when there are connecting elements at the beginning or end of a channel.

Code Item

A01368 Travetta B joint closing cap

A01370 Travetta GR joint closing cap

Connecting element between luminaires or between luminaire and wall, white or grey RAL 9006 colour, composed of aluminium tube 1.5 m long Ø20 mm, which can be sectioned to any desired length, it allows the passage of the power-supply line.

Code Item

A0869 Grey connecting element with boss for luminaires

A0870 White connecting element with boss for luminaires

A0871 Grey connecting element to wall with boss for luminaires

A0872 White connecting element to wall with boss for luminaires

Accessories

3F Travetta

Branch in correspondence with linear connecting elements, in steel with accessorizable cover, white or grey RAL 9006 colour.

Code Item

A0945 Branches elem.190x310 3F Travetta GR

A0946 Branches elem.190x460 3F Travetta GR

A0951 White branches elem. 190x310 3F Travetta

A0952 White branches elem. 190x460 3F Travetta

A0877 Bracket for T-branch for 3F Travetta

A0878 Bracket for X-branch for 3F Travetta

It allows the passage of the power-supply line.The linear connecting element 190x190 can be used also for T-branches (it needs one bracket code A0875) and X-branches (it needs two brackets code A0875).The connecting elements are used for T-branches (they need one bracket code A0877) and X-branches (they need one bracket code A0878).To obtain an excellent T- or X-branch in correspondence with the connecting elements for false ceiling with exposed profiles 600x600, it is advisable to couple the linear connecting element 1110 mm with branch 460 mm and the linear connecting element 810 mm with branch 310 mm.

Page 65: 3F Filippi  "General catalogue 2016"

62

Clamps in nickel-plated brass suitable for fixing of steel wire (diameter 1.25 mm - 1.5 mm - 2 mm), complete with locking screws.

Code Item

A0622 Clamp 1 hole - 100 pcs

Coil of stainless steel cable “Ø 1.25 mm”, length 100 m.

Code Item

A0620 Spool with stainless steel cable diam. 1,25mm 100 m

Accessories

3F Travetta

Fixed suspension with white polycarbonate case, internal bracket in galvanized steel.Wired version with transparent power-supply cable 5x1.5 mm².Stainless steel cables leaded at the end for coupling on the luminaire.

Code Item

A01314 White rectangular case suspension- fixed 0,3m

A01315 White rectangular case suspension- fixed 0,5m

A01317 White rectangular case suspension- fixed 1m

A01321 Wired susp. 5P white rectangular case-fixed 0,3m

A01322 Wired susp. 5P white rectangular case-fixed 0,5m

A01324 Wired suspension 5P white rectangular case-fixed 1m

Page 66: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 67: 3F Filippi  "General catalogue 2016"
Page 68: 3F Filippi  "General catalogue 2016"

3F info point

Filigare range luminaires are available in two versions:

Filigare - single luminaires3F Fil - luminaires to create continuous lighting channels

Both offer various possibilities of lighting distribution, direct and direct/indirect, wide and medium, symmetrical and asymmetrical, to optimise lighting of the work area.

Filigare Range

Filigare - single luminaires

Available sources:- T5 or T8 Fluorescent

- LED

Standard features:- End caps

- Pre-mounted T5 lamps

Accessories:- Kit to create continuous lines

3F Fil - luminaires to create continuous lighting channels

Available sources:- T5 fluorescent

- LED

Standard features:- Through power supply lines

- Connection kit already fitted on one cap

Accessories:- End caps

Page 69: 3F Filippi  "General catalogue 2016"

66

New

Filigare 180 LEDLED luminaire for high energy efficiency systems and total shielding of the louvre compartment

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Metal end caps with cover element in white polycarbonate, removable to form channels.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.2+2 in-line twin circuit wiring.

Dimensions

Applications

2US versionEnvironments: with VDTs, schools, offices.Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.High energy efficiency systems.

Installation

In the case of 2US unit ceiling installation, concealed sliding brackets (accessory) are always necessary.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers or colour temperatures• asymmetric luminaires• housing and accessories in RAL colours• wiring: dimmable, emergency

Accessories

Accessories on page 82.

L

H

A

H

Page 70: 3F Filippi  "General catalogue 2016"

67Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 180 LED 2US

Code 12603

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12601 Fil 180 LED 1x24W 2US L1280 28 2745 1280x180x85

12603 Fil 180 LED 1x30W 2US L1590 34 3435 1590x180x85

12605 Fil 180 LED 2x24W 2US L1280 56 4778 1280x180x85

12607 Fil 180 LED 2x30W 2US L1590 68 5980 1590x180x85

12614 Fil 180 LED 1+1x30W 2US L3140 68 6870 3140x180x85

12618 Fil 180 LED 2+2x30W 2US L3140 136 11960 3140x180x85

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 180 LED RSP

Code 12403

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12403 Fil 180 LED 2x24W RSP AMPIO L1280 56 6742 1280x180x85

12404 Fil 180 LED 2x30W RSP AMPIO L1590 68 8421 1590x180x85

Filigare 180 LED

E=100%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.SP diffuser in self-extinguishing V2 transparent polycarbonate, photo-engraved inside, UV stabilised, injection moulded with smooth outside.

Page 71: 3F Filippi  "General catalogue 2016"

68

Filigare 180 FluoLuminaire with parabolic louvre or flux recuperator

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Metal end caps with cover element in white polycarbonate, removable to form channels.Parabolic louvres with transverse blades closed at the top.Parabolic flux recuperator.Film protective against dust and finger marks, adhesive, attached to louvre.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.2+2 version with twin-circuit wiring, lamps side by side.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

2M, 2MG, 2US versionsEnvironments: with VDTs, schools, offices.3AO versionEnvironments: architectural, commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.RFMG versionEnvironments: commercial, exhibition areas, transit areas, halls, shops, great halls, display windows.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• parabolic louvres 3DEC• asymmetric luminaires in 2M and 2US

versions• 1+1x36-58 luminaires with electronic wiring• Multiwatt electronic ballasts for T5 lamps• multilenticular transparent PMMA diffuser• matt metallic silver end caps• fuse accessory (on page 472)• wiring: dimmable, emergency with

different characteristics• emergency inhibition

Accessories

Accessories on page 82.

L

H

A

H

Page 72: 3F Filippi  "General catalogue 2016"

69Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 180 T5 2M

Code 11012

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11006 Fil 180 1x28 T5 HF 2M 31 2600 1210x180x85

11007 Fil 180 1x35 T5 HF 2M 38 3300 1510x180x85

11008 Fil 180 1+1x28 T5 HF 2M 60 5200 2380x180x85

11011 Fil 180 2x28 T5 HF 2M 60 5200 1210x180x85

11009 Fil 180 1+1x35 T5 HF 2M 76 6600 2980x180x85

11012 Fil 180 2x35 T5 HF 2M 76 6600 1510x180x85

11013 Fil 180 2+2x28 T5 HF 2M 120 10400 2380x180x85

11014 Fil 180 2+2x35 T5 HF 2M 152 13200 2980x180x85

EP emergency, fuse - Pre-mounted lamps

11016 Fil 180 1x28 T5 HF EP 2M 31 2600 1210x180x85

11017 Fil 180 1x35 T5 HF EP 2M 38 3300 1510x180x85

11021 Fil 180 2x28 T5 HF EP 2M 60 5200 1210x180x85

11022 Fil 180 2x35 T5 HF EP 2M 76 6600 1510x180x85

Filigare 180 Fluo

L<200 cd/m² 65°

E>61%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 73: 3F Filippi  "General catalogue 2016"

70

Filigare 180 T5 2MG

Code 11072

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11066 Fil 180 1x28 T5 HF 2MG 31 2600 1210x180x85

11067 Fil 180 1x35 T5 HF 2MG 38 3300 1510x180x85

11068 Fil 180 1+1x28 T5 HF 2MG 60 5200 2380x180x85

11071 Fil 180 2x28 T5 HF 2MG 60 5200 1210x180x85

11069 Fil 180 1+1x35 T5 HF 2MG 76 6600 2980x180x85

11072 Fil 180 2x35 T5 HF 2MG 76 6600 1510x180x85

11073 Fil 180 2+2x28 T5 HF 2MG 120 10400 2380x180x85

11074 Fil 180 2+2x35 T5 HF 2MG 152 13200 2980x180x85

L<200 cd/m² 65°

E>67%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 180 T8 2M

Code 11047

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11046 Fil 180 1x36 HF 2M 36 3350 1280x180x85

11047 Fil 180 1x58 HF 2M 55 5200 1590x180x85

EP emergency, fuse - Lamps not included

11051 Fil 180 1x36 HF EP 2M 36 3350 1280x180x85

11052 Fil 180 1x58 HF EP 2M 55 5200 1590x180x85

Filigare 180 Fluo

L<200 cd/m² 65°

E>62%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 74: 3F Filippi  "General catalogue 2016"

71Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 180 T5 2US

Code 11132

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11126 Fil 180 1x28 T5 HF 2US 31 2600 1210x180x85

11127 Fil 180 1x35 T5 HF 2US 38 3300 1510x180x85

11128 Fil 180 1+1x28 T5 HF 2US 60 5200 2380x180x85

11131 Fil 180 2x28 T5 HF 2US 60 5200 1210x180x85

11129 Fil 180 1+1x35 T5 HF 2US 76 6600 2980x180x85

11132 Fil 180 2x35 T5 HF 2US 76 6600 1510x180x85

11133 Fil 180 2+2x28 T5 HF 2US 120 10400 2380x180x85

11134 Fil 180 2+2x35 T5 HF 2US 152 13200 2980x180x85

EP emergency, fuse - Pre-mounted lamps

11136 Fil 180 1x28 T5 HF EP 2US 31 2600 1210x180x85

11137 Fil 180 1x35 T5 HF EP 2US 38 3300 1510x180x85

11141 Fil 180 2x28 T5 HF EP 2US 60 5200 1210x180x85

11142 Fil 180 2x35 T5 HF EP 2US 76 6600 1510x180x85

L<200 cd/m² 65°

E>60%

Average luminance <200 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 180 T8 2MG

Code 11107

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11106 Fil 180 1x36 HF 2MG 36 3350 1280x180x85

11107 Fil 180 1x58 HF 2MG 55 5200 1590x180x85

Filigare 180 Fluo

L<200 cd/m² 65°

E>70%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 75: 3F Filippi  "General catalogue 2016"

72

Filigare 180 T8 2US

Code 11167

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11166 Fil 180 1x36 HF 2US 36 3350 1280x180x85

11167 Fil 180 1x58 HF 2US 55 5200 1590x180x85

EP emergency, fuse - Lamps not included

11171 Fil 180 1x36 HF EP 2US 36 3350 1210x180x85

11172 Fil 180 1x58 HF EP 2US 55 5200 1510x180x85

Filigare 180 Fluo

L<200 cd/m² 65°

E>61%

Average luminance <200 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 76: 3F Filippi  "General catalogue 2016"

73Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 180 T5 3AO

Code 11312

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11306 Fil 180 1x28 T5 HF 3AO 31 2600 1210x180x85

11307 Fil 180 1x35 T5 HF 3AO 38 3300 1510x180x85

11308 Fil 180 1+1x28 T5 HF 3AO 60 5200 2380x180x85

11311 Fil 180 2x28 T5 HF 3AO 60 5200 1210x180x85

11309 Fil 180 1+1x35 T5 HF 3AO 76 6600 2980x180x85

11312 Fil 180 2x35 T5 HF 3AO 76 6600 1510x180x85

11313 Fil 180 2+2x28 T5 HF 3AO 120 10400 2380x180x85

11314 Fil 180 2+2x35 T5 HF 3AO 152 13200 2980x180x85

EP emergency, fuse - Pre-mounted lamps

11316 Fil 180 1x28 T5 HF EP 3AO 31 2600 1210x180x85

11317 Fil 180 1x35 T5 HF EP 3AO 38 3300 1510x180x85

11321 Fil 180 2x28 T5 HF EP 3AO 60 5200 1210x180x85

11322 Fil 180 2x35 T5 HF EP 3AO 76 6600 1510x180x85

Filigare 180 Fluo

E>56%

1x - Average luminance <3000 cd/m² for radial angles >65°.3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 77: 3F Filippi  "General catalogue 2016"

74

Filigare 180 T5 RFMG

Code 4301

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

4301 Fil 180 1x49 T5 HF RFMG 53 4300 1510x180x80

4300 Fil 180 1x54 T5 HF RFMG 58 4450 1210x180x80

4302 Fil 180 1x80 T5 HF RFMG 86 6150 1510x180x80

4304 Fil 180 1+1x49 T5 HF RFMG 106 8600 2980x180x80

4303 Fil 180 1+1x54 T5 HF RFMG 114 8900 2380x180x80

4305 Fil 180 1+1x80 T5 HF RFMG 170 12300 2980x180x80

E>91%

RFMG flux recuperator in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.Cathode-covers in white polycarbonate for IP40 and to prevent lamp from falling.

Filigare 180 T8 3AO

Code 11347

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11346 Fil 180 1x36 HF 3AO 36 3350 1280x180x85

11347 Fil 180 1x58 HF 3AO 55 5200 1590x180x85

EP emergency, fuse - Lamps not included

11351 Fil 180 1x36 HF EP 3AO 36 3350 1280x180x85

11352 Fil 180 1x58 HF EP 3AO 55 5200 1590x180x85

Filigare 180 Fluo

E>58%

3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 78: 3F Filippi  "General catalogue 2016"

75Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 180 T8 RFMG

Code 4106

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

4105 Fil 180 1x36 HF RFMG 36 3350 1280x180x80

4106 Fil 180 1x58 HF RFMG 55 5200 1590x180x80

Filigare 180 Fluo

E>91%

Variable focus through plate regulator (supplied).RFMG flux recuperator in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.Cathode-covers in white polycarbonate for IP40 and to prevent lamp from falling.

Page 79: 3F Filippi  "General catalogue 2016"

76

Filigare 220 FluoLuminaire for ceiling installation and/or suspension

Construction characteristics

Illuminotechnical characteristicsDirect symmetric lighting distribution.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Metal end caps with cover element in white polycarbonate, removable to form channels.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

3AO, SP versionsEnvironments: architectural, commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.2M, 2US versionsEnvironments: with VDTs, schools, offices.RFMG versionEnvironments: commercial, exhibition areas, transit areas, halls, shops, great halls, display windows.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• parabolic louvres 3DEC• 2+2x36-58 luminaires with electronic wiring• Multiwatt electronic ballasts for T5 lamps• fuse accessory (on page 472)• wiring: dimmable, emergency with

different characteristics• emergency inhibition

Accessories

Accessories on page 82.

A

H

L

H

Page 80: 3F Filippi  "General catalogue 2016"

77Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 220 T8 2M

Code 11757

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11756 Fil 220 2x36 HF 2M 71 6700 1280x220x85

11757 Fil 220 2x58 HF 2M 109 10400 1590x220x85

EP emergency, fuse - Lamps not included

11761 Fil 220 2x36 HF EP 2M 71 6700 1280x220x85

11762 Fil 220 2x58 HF EP 2M 109 10400 1590x220x85

L<1000 cd/m² 65°

E>63%

Average luminance <1000 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 220 T5 2M

Code 11727

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11726 Fil 220 2x28 T5 HF 2M 60 5200 1210x220x85

11727 Fil 220 2x35 T5 HF 2M 76 6600 1510x220x85

EP emergency, fuse - Pre-mounted lamps

11731 Fil 220 2x28 T5 HF EP 2M 60 5200 1210x220x85

11732 Fil 220 2x35 T5 HF EP 2M 76 6600 1510x220x85

Filigare 220 Fluo

L<1000 cd/m² 65°

E>65%

Average luminance <1000 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 81: 3F Filippi  "General catalogue 2016"

78

Filigare 220 T8 2US

Code 11857

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

11856 Fil 220 2x36 HF 2US 71 6700 1280x220x85

11857 Fil 220 2x58 HF 2US 109 10400 1590x220x85

EP emergency, fuse - Lamps not included

11861 Fil 220 2x36 HF EP 2US 71 6700 1280x220x85

11862 Fil 220 2x58 HF EP 2US 109 10400 1590x220x85

L<1000 cd/m² 65°

E>61%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 220 T5 2US

Code 11827

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11826 Fil 220 2x28 T5 HF 2US 60 5200 1210x220x85

11827 Fil 220 2x35 T5 HF 2US 76 6600 1510x220x85

EP emergency, fuse - Pre-mounted lamps

11831 Fil 220 2x28 T5 HF EP 2US 60 5200 1210x220x85

11832 Fil 220 2x35 T5 HF EP 2US 76 6600 1510x220x85

Filigare 220 Fluo

L<1000 cd/m² 65°

E>63%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 82: 3F Filippi  "General catalogue 2016"

79Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 220 T8 3AO

Code 12007

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

12006 Fil 220 2x36 HF 3AO 71 6700 1280x220x85

12007 Fil 220 2x58 HF 3AO 109 10400 1590x220x85

EP emergency, fuse - Lamps not included

12011 Fil 220 2x36 HF EP 3AO 71 6700 1280x220x85

12012 Fil 220 2x58 HF EP 3AO 109 10400 1590x220x85

E>60%

3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Filigare 220 T5 3AO

Code 11977

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

11976 Fil 220 2x28 T5 HF 3AO 60 5200 1210x220x85

11977 Fil 220 2x35 T5 HF 3AO 76 6600 1510x220x85

EP emergency, fuse - Pre-mounted lamps

11981 Fil 220 2x28 T5 HF EP 3AO 60 5200 1210x220x85

11982 Fil 220 2x35 T5 HF EP 3AO 76 6600 1510x220x85

Filigare 220 Fluo

E>62%

3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 83: 3F Filippi  "General catalogue 2016"

80

Filigare 220 T5 RFMG

Code 4319

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

4319 Fil 220 2x49 T5 HF RFMG 106 8600 1510x220x80

4318 Fil 220 2x54 T5 HF RFMG 114 8900 1210x220x80

4320 Fil 220 2x80 T5 HF RFMG 170 12300 1510x220x80

E>92%

RFMG flux recuperator in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.Cathode-covers in white polycarbonate for IP40 and to prevent lamp from falling.

Filigare 220 T8 SP

Code 4351

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

4350 Fil 220 2x36 HF SP 71 6700 1280x220x80

4351 Fil 220 2x58 HF SP 109 10400 1590x220x80

EP emergency, fuse - Lamps not included

4354 Fil 220 2x36 HF EP SP 71 6700 1280x220x80

4355 Fil 220 2x58 HF EP SP 109 10400 1590x220x80

Filigare 220 Fluo

E>52%

SP transparent methacrylate diffuser, prismatic outside, antiglare.

Page 84: 3F Filippi  "General catalogue 2016"

81Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Filigare 220 T8 RFMG

Code 4176

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

4175 Fil 220 2x36 HF RFMG 71 6700 1280x220x80

4176 Fil 220 2x58 HF RFMG 109 10400 1590x220x80

Filigare 220 Fluo

E>83%

Mariable focus, through plate regulator (accessory).RFMG flux recuperator in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.Cathode-covers in white polycarbonate for IP40 and to prevent lamp from falling.

Page 85: 3F Filippi  "General catalogue 2016"

82

Branch box in white painted steel for L, T and cross-shaped branches.Possibility of suspension at the centre of the box, see suspension (cod. A0045 - A0046 - A0047 - A0762 - A0766 - A0770).A hermetic junction box can be housed internally.

Code Item

A0036 Fil 180 BL (box for branch)

A0037 Fil 220 BL (box for branch)

Connecting element for Filigare 180 for variable interdistances between luminaires, composed of a pair of adapter cylinders and aluminium tube 1.5 m long, Ø35 mm, which can be sectioned to any desired length.

Code Item

A0034 Pair of white cylinders

A0035 Aluminium tube 1.5 m white

The branch end cap is always necessary.

Bracket to strengthen structures connection in white painted steel for continuous channel of considerable length, complete with kit for continuous channel, one bracket every two connections is recommended.

Code Item

A0066 Strength. Brack.+Connect. Kit - Fil 180

A0067 Strength. Brack.+Connect. Kit - Fil 220

Kit for continuous channel composed of blend stop and two screws with nuts.

Code Item

A0030 Fil 180 CC (continuous channel kit)

A0031 Fil 220 CC (continuous channel kit)

Accessories

Filigare

Structure, Filigare 180-220 in hot-galvanized steel painted in white polyester.

Code Item

A0006 Fil 180 CP620 Structure

A0008 Fil 180 CP1240 Structure

A0009 Fil 180 CP1550 Structure

A0011 Fil 220 CP620 Structure

A0013 Fil 220 CP1240 Structure

A0014 Fil 220 CP1550 Structure

Page 86: 3F Filippi  "General catalogue 2016"

83Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Suspension composed by: polycarbonate ceiling white rose Ø 110 mm, stainless steel cable Ø 1,25 mm (length 1 m), quick adjuster, white power cable 1,5 mm² section, H05VV-F (length 2 m).

Code Item

A0124 Rose 110 (Adjust. susp.1m unwired)

A0125 Rose 110 (Adjust. susp.1m wired with 4-pole cable)

A0114 Rose 110 (Adjust. susp.1m wired with 5-pole cable)

Concealed sliding bracket for free positioning, in galvanized steel, for mounting to or suspension from the ceiling.It can be adjusted at two heights to position the structure at distances of 16 or 21 mm from the ceiling.It allows mounting also on normally flammable surfaces.

Code Item

A0042 Fil 180 SS (sliding bracket)

A0043 Fil 220 SS (sliding bracket)

Pair of end cap cover elements (in white polycarbonate), complete with fixing bolts.

Code Item

A0039 Pair of white end caps Fil 180

A0040 Pair of white end caps Fil 220

Articulated connecting element in white polycarbonate; it is not a mechanical support; it allows the passage of power-supply line.It must always be coupled with 2 elements for branch connection (cod. A0033).

Code Item

A0038 White articulated connecting element

Accessories

Filigare

Elements for branch and for wall-mounting, Filigare 180 in white polycarbonate, interchangeable with standard end caps.

Code Item

A0033 Fil 180 DT (element for branch)

Page 87: 3F Filippi  "General catalogue 2016"

84

Cable clip in polycarbonate, snap-lock fastening in side compartment; it is advisable to use it every meter.

Code Item

A0053 Fil 19 BF (cable clip)

Electrical socket with white polycarbonate ceiling rose Ø 86 mm, white cable 4x1.5 mm², H05VV-F (length 2 m).

Code Item

A0130 Rose 86 (4-pole wired boss)

Clamps in nickel-plated brass suitable for fixing of steel wire (diameter 1.25 mm - 1.5 mm - 2 mm), complete with locking screws.

Code Item

A0622 Clamp 1 hole - 100 pcs

Coil of stainless steel cable “Ø 1.25 mm”, length 100 m.

Code Item

A0620 Spool with stainless steel cable diam. 1,25mm 100 m

Accessories

Filigare

Adjustable suspension for continuous channel composed of white polycarbonate case, internal bracket in galvanized steel, cables Ø 2 mm in galvanized steel, quick adjusters, maximum load 50 Kg.

Code Item

A0045 Adjustable suspension for channel 1m

A0046 Adjustable suspension for channel 1.5m

A0047 Adjustable suspension for channel 2m

A0762 Adjustable suspension for channel 3m

A0766 Adjustable suspension for channel 4m

A0770 Adjustable suspension for channel 6m

For continuous channel it is always necessary to use the sliding bracket (cod. A0042).On request steel cable, spool of 100 or 500 m.

Page 88: 3F Filippi  "General catalogue 2016"

85Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

White closing strip in PVC to be attached by fitting into position in Filigare 180 structure.

Code Item

A0016 32 IF (PVC closing top Fil 180-620)

A0018 32 MH (PVC closing top Fil 180-1240)

A0019 32 HA (PVC closing top Fil 180-1550)

SP diffuser for Filigare 180 T8 single or channel luminaires with flow recuperator, in transparent polycarbonate, UV stabilised, injection moulded with smooth outer surface and differentiated prismatic inner surface.

Code Item

A0060 21 V2 (PC diffuser 58W Fil180/3F1)

A0062 21 V2C (PC diffuser 36W Fil180/3F1)

A0061 21 V0 (PC diffuser 58W Fil180/3F1)

A0063 21 V0C (PC diffuser 36W Fil180/3F1)

SP flat diffuser for Filigare single or channel luminaires with flow recuperator, in transparent polycarbonate, UV stabilized, self-extinguishing V2.

Code Item

A0058 Flat diffuser PC transp. Fil180 36 sing.

A0059 Flat diffuser PC transp. Fil180 58 sing.

A0846 Flat diffuser PC transp. Fil180 28-54 sing.

A0847 Flat diffuser PC transp. Fil180 35-49 -80 sing.

A0848 Flat diffuser PC transp. Fil180 28-54 chan.

A0849 Flat diffuser PC transp. Fil180 35-49 -80 chan.

A0064 21 RD (PC single diffuser transp. 36 WFil220)

A0065 21 AT (PC single diffuser transp. 58 WFil220)

A0862 Flat diffuser PC transp. Fil220 28-54 sing.

A0863 Flat diffuser PC transp. Fil220 35-49-80 sing.

A0864 Flat diffuser PC transp. Fil220 28-54 chan.

A0865 Flat diffuser PC transp. Fil220 35-49-80 chan.

Accessories

Filigare

Lamp holder for variable focusing for Filigare 220 T8 with flow recuperator, in white polycarbonate, for wide or asymmetric distribution.For n° 2 lamps.

Code Item

A0051 34 MF (variable lamp focusing Fil 220 T8)

Page 89: 3F Filippi  "General catalogue 2016"

86

Wall-mounting bracket for Filigare 180, in white painted steel, suitable for mounting on the sliding bracket (cod. 0042) (always necessary).

Code Item

A0052 Fil 15 FP (wall-mounting bracket Fil 180)

Accessories

Filigare

White closing strip in steel, to be attached by fitting into position in Filigare 180-220 structure.

Code Item

A0021 Fil 180 AB620 (steel closing top)

A0023 Fil 180 AB1240 (steel closing top)

A0024 Fil 180 AB1550 (steel closing top)

A0026 Fil 220 AB620 (steel closing top)

A0028 Fil 220 AB1240 (steel closing top)

A0029 Fil 220 AB1550 (steel closing top)

On request: in RAL colour.

Page 90: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 91: 3F Filippi  "General catalogue 2016"

88

Fly2 LEDLED pendant luminaire for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsSymmetric direct-indirect distribution.Average luminance <3000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing and end caps in white painted aluminium.End caps cover elements in white polycarbonate.Suspensions always necessary, see accessories.

Electrical characteristicsDALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: staterooms, with VDTs, meeting rooms, offices.Environments where soft diffuse light is required for optimal visual comfort.

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers or colour temperatures• housing and accessories in RAL colours• wiring: non dimmable

Accessories

Accessories on page 96.

HA

L

H

Page 92: 3F Filippi  "General catalogue 2016"

89Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Fly2 LED B SP

Code 12120

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

12120 Fly2 LED B 2x24W DALI SP L1316 56 6557 1316x320x61

Fly2 LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Flow recuperators in specular aluminium, high efficiency.Upper diffuser in translucent polycarbonate.SP lower diffuser in prismatic transparent PMMA.

Page 93: 3F Filippi  "General catalogue 2016"

90

New

Fly2 Free-standing LEDLED floor-standing luminaire for energy efficient systems

Construction characteristics

Illuminotechnical characteristicsIndirect, direct distribution.Maximum spread of the indirect luminous flux, for lighting uniformity on ceiling.Average luminance <3000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing and end caps in white painted aluminium.End caps cover elements in white polycarbonate.Flux recuperator in specular aluminium, high efficiency.Upper diffuser in translucent polycarbonate.Lower flat diffuser in PMMA transparent, prismatic, with anti-glare filter in white micro-perforated steel.Rectangular section 25x50 mm white pole.Base in white painted steel with level adjusters and nonslip rubber tips.IP40 protection degree.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Power-supply with black cable 2.5 m long, schuko plug and foot switch.

Dimensions

Applications

Environments: staterooms, with VDTs, offices.Environments where soft diffuse light is required for optimal visual comfort.Environments which cannot, for technical reasons, be equipped with points of light directed onto the ceiling.Open-space offices and environments in which a high degree of workstation flexibility is required.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• housing in grey RAL 9006• twin-circuit• version for installation on desks and tables• version with integrated sensor or table console

H

A L

Page 94: 3F Filippi  "General catalogue 2016"

91Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Fly2 Free-standing LED

Code 15896

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

15896 New Fly2 Piantana LED 5x10W SPM L717 55 5363 717x320x2047

Fly2 Free-standing LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Flow recuperators in specular aluminium, high efficiency.Upper diffuser in translucent polycarbonate.SPM lower diffuser in transparent PMMA prismatic with anti-glare filter in white micro-perforated steel.

Page 95: 3F Filippi  "General catalogue 2016"

92

Fly2 FluoSuspension luminaire with direct and indirect light distribution

Construction characteristics

Illuminotechnical characteristicsHigh luminous efficiency >80%.Direct-indirect diffused distribution.

Mechanical characteristicsHousing and end caps in white RAL 9010 (B) or grey RAL 9006 (GR) painted aluminium.Flow recuperators in semi-specular aluminium, high efficiency.Upper diffuser in transparent polycarbonate and lower diffuser in PMMA for lampcompartment closure.End caps cover elements in white polycarbonate on white housing and grey polycarbonate on grey housing.Suspensions always necessary, see accessories.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.DALI MultiWatt EEI A1 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit in 4x35 and 4x49 versions.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Accessories

Accessories on page 96.

Applications

Environments where soft diffuse light is required for optimal visual comfort.SPM versionEnvironments: staterooms, with VDTs, meeting rooms, offices.For uniform light on ceiling, we recommend suspending the luminaire at a minimum distance of 30 cm.

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

Fly 2 is equipped with MultiWatt wiring which allows the lamps to be changed, for example:• 28 to 54W or vice versa• 35 to 49W or vice versaThis allows the level of illumination to be optimised when changing the use of the room the product is installed in.

On request

• lamps in different powers or colour temperatures

• luminaires for white painted luminous channels

• housing in different RAL colours• fuse accessory (on page 472)• wiring: emergency• emergency inhibition

HA

L

H

Page 96: 3F Filippi  "General catalogue 2016"

93Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Fly2 B SPM - GR SPM

Code 15426

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

15428 Fly2 B 2x49 T5 LD HF SPM 106 8600 1616x320x61

15426 Fly2 B 2x54 T5 LD HF SPM 114 8900 1316x320x61

15433 Fly2 B 4x49 T5 LD HF DA SPM 212 17200 1616x320x61

White housing - DALI EEI A1 electronic - Pre-mounted lamps

16060 Fly2 B 2x49 T5 LD HF DALI SPM 106 8600 1616x320x61

16058 Fly2 B 2x54 T5 LD HF DALI SPM 114 8900 1316x320x61

16067 Fly2 B 4x49 T5 LD HF DALI SPM 212 17200 1616x320x61

White housing - EP emergency, fuse - Pre-mounted lamps

15441 Fly2 B 2x54 T5 LD HF EP SPM 114 8900 1316x320x61

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

15698 Fly2 GR 2x49 T5 LD HF SPM 106 8600 1616x320x61

15696 Fly2 GR 2x54 T5 LD HF SPM 114 8900 1316x320x61

15703 Fly2 GR 4x49 T5 LD HF DA SPM 212 17200 1616x320x61

Grey housing - DALI EEI A1 electronic - Pre-mounted lamps

16144 Fly2 GR 2x49 T5 LD HF DALI SPM 106 8600 1616x320x61

16142 Fly2 GR 2x54 T5 LD HF DALI SPM 114 8900 1316x320x61

16151 Fly2 GR 4x49 T5 LD HF DALI SPM 212 17200 1616x320x61

Grey housing - EP emergency, fuse - Pre-mounted lamps

15713 Fly2 GR 2x49 T5 LD HF EP SPM 106 8600 1616x320x61

15711 Fly2 GR 2x54 T5 LD HF EP SPM 114 8900 1316x320x61

Fly2 Fluo

L<1000 cd/m² 65°

E>80%

Indirect E>65%

Direct E>15%

2x - Average luminance <1000 cd/m² for radial angles >65°.4x - Average luminance <2000 cd/m² for radial angles >65°.Flow recuperators in semi-specular aluminium, high efficiency.Upper diffuser in transparent polycarbonate.SPM lower diffuser in transparent PMMA prismatic with anti-glare filter in white micro-perforated steel.

Page 97: 3F Filippi  "General catalogue 2016"

94

Fly2 B SP - GR SP

Code 15741

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

15470 Fly2 B 2x28 T5 LD HF SP 60 5200 1316x320x61

15471 Fly2 B 2x54 T5 LD HF SP 114 8900 1316x320x61

15478 Fly2 B 4x49 T5 LD HF DA SP 212 17200 1616x320x61

Grey housing - EEI A2 electronic wiring - Pre-mounted lamps

15740 Fly2 GR 2x28 T5 LD HF SP 60 5200 1316x320x61

15741 Fly2 GR 2x54 T5 LD HF SP 114 8900 1316x320x61

15748 Fly2 GR 4x49 T5 LD HF DA SP 212 17200 1616x320x61

E>91%

Indirect E>57%

Direct E>34%

Flow recuperators in semi-specular aluminium, high efficiency.Upper diffuser in transparent polycarbonate.SP lower diffuser in prismatic transparent PMMA.

Fly2 GR SPM IFC

Code 17479

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Grey housing - DALI EEI A1 electronic - Pre-mounted lamps

17479 Fly2 GR 2x49 T5 LD HF DALI SPM IFC 106 8600 1616x320x61

Fly2 Fluo

L<1000 cd/m² 65°

E>76%

Indirect E>62%

Direct E>14%

2x - Average luminance <1000 cd/m² for radial angles >65°.Flow recuperators in semi-specular aluminium, high efficiency.Upper diffuser in transparent polycarbonate.SPM lower diffuser in transparent PMMA prismatic with anti-glare filter in white micro-perforated steel.LUMINAIRES WITH COVER ELEMENTS PRE-ARRANGED TO OBTAIN LUMINOUS CHANNELS, CONNECTING ELEMENT IS ALWAYS NECESSARY.

Page 98: 3F Filippi  "General catalogue 2016"

95Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Fly2 B Opal

Code 15381

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing - EEI A2 electronic wiring - Pre-mounted lamps

15380 Fly2 B 2x28 T5 LD HF OP 60 5200 1316x320x61

15381 Fly2 B 2x54 T5 LD HF OP 114 8900 1316x320x61

15388 Fly2 B 4x49 T5 LD HF DA OP 212 17200 1616x320x61

Fly2 Fluo

E>80%

Indirect E>54%

Direct E>26%

Flow recuperators in semi-specular aluminium, high efficiency.Upper diffuser in transparent polycarbonate.OP lower diffuser in PMMA opal PMMA.

Page 99: 3F Filippi  "General catalogue 2016"

96

Linear connecting element for channels, to be used with luminaires IFC, made of painted steel gray RAL 9006, with upper holes for suspension.It allows the passage of power-supply cable and spaces the luminaires of 40 mm.

Code Item

A01353 Connecting element for Fly2 GR

Presence and light sensor with cover, to be installed on one end of the luminaire, that which is mostly influenced by the natural light or by the presence of people in the working zone, usable only in HF DALI dimmable wiring, it can control up to 4 ballasts.

Code Item

A01350 Presence and light sensor Fly2 B

A01351 Presence and light sensor Fly2 GR

Clamps in nickel-plated brass suitable for fixing of steel wire (diameter 1.25 mm - 1.5 mm - 2 mm), complete with locking screws.

Code Item

A0622 Clamp 1 hole - 100 pcs

Coil of stainless steel cable “Ø 1.25 mm”, length 100 m.

Code Item

A0620 Spool with stainless steel cable diam. 1,25mm 100 m

Accessories

Fly2

Adjustable suspension with polycarbonate case in white colour, internal bracket in galvanized steel.Wired version with transparent power cable 5x1.5 mm².Stainless steel cables, length 1 m, leaded at one end with adjusters for coupling on the luminaire.

Code Item

A01318 White rectangular case suspension-adj. 1 m

A01325 Wired suspension 5P white rectangular case-adj.1 m

On request:for suspensions longer than 1 m, it is necessary not only to order codes 01318-01325 but also stainless steel cables in spool of 100 m and pack of n° 100 clamps.

Page 100: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 101: 3F Filippi  "General catalogue 2016"

98

P 200 LEDLED ceiling luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted steel.2US parabolic louvre in semi-glossy aluminium with transverse blades closed at the top and prismatic PMMA diffusers for total shielding of the louvre compartment.SP transparent PMMA diffuser, prismatic, anti-glare, locked to the pre-painted white aluminium perimeter frame with sealing gasket, hinged opening.OP opal PMMA flat diffuser, anti-glare, locked to the pre-painted white aluminium perimeter frame with sealing gasket, hinged opening.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

2US versionEnvironments: with VDTs, schools, offices.SP versionEnvironments: staterooms, with VDTs, offices.Environments with exacting visual tasks, where diffused soft light for optimum visual comfort is required.OP versionEnvironments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

10W version• Color initial tolerance (MacAdam): 2.24W, 30W versions• Color initial tolerance (MacAdam): 3.

On request

• parabolic louvres 2M, 2MG, 3AO• different powers or colour temperatures• diffuser in SMP microprismatic PMMA or

SP polycarbonate, Selfextinguishing V2• housing and accessories in RAL colours• wiring: dimmable, emergency

L

H

H

A

Page 102: 3F Filippi  "General catalogue 2016"

99Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

P 200 LED SP

Code 12708

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12720 P 203x10W LED SP 596x596 34 3935 596x596x82

12703 P 201x30W LED SP 156x1531 34 3939 1531x156x82

12722 P 204x10W LED SP 596x596 45 5207 596x596x82

12708 P 202x24W LED SP 196x1231 56 6249 1231x196x82

12710 P 202x30W LED SP 196x1531 68 7819 1531x196x82

L<3000 cd/m² 65°

E=100%

10W - Average luminance <3000 cd/m² for radial angles >65°.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

P 200 LED 2US

Code 12680

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12675 P 201x30W LED 2US 156x1531 34 3324 1531x156x82

12692 P 203x10W LED 2US 596x596 34 3537 596x596x82

12687 P 202x24W LED 2US 270x1231 56 5221 1231x270x82

12680 P 202x24W LED 2US 196x1231 56 5544 1231x196x82

12689 P 202x30W LED 2US 270x1531 68 6528 1531x270x82

12682 P 202x30W LED 2US 196x1531 68 6929 1531x196x82

P 200 LED

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 103: 3F Filippi  "General catalogue 2016"

100

P 200 LED Opal

Code 12736

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12748 P 203x10W LED OP 596x596 34 3491 596x596x82

12731 P 201x30W LED OP 156x1531 34 3494 1531x156x82

12750 P 204x10W LED OP 596x596 45 4620 596x596x82

12736 P 202x24W LED OP 196x1231 56 5545 1231x196x82

12738 P 202x30W LED OP 196x1531 68 6938 1531x196x82

P 200 LED

E=100%

High visual comfort.OP opal PMMA flat diffuser, anti-glare, locked to the pre-painted white aluminium perimeter frame with sealing gasket, hinged opening.

Page 104: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 105: 3F Filippi  "General catalogue 2016"

102

P 200 FluoCeiling luminaire

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsHousing in white painted steel.Parabolic louvres with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

Dimensions

Applications

2M, 2MG, 2US versionsEnvironments: with VDTs, schools, offices.

On request

• fuse accessory (on page 472)• wiring: dimmable, twin-circuit,

emergency

L

H

H

A

Page 106: 3F Filippi  "General catalogue 2016"

103Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

P 200 2M

Code 10030

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

10025 P 201x18 HF 2M 19 1350 622x156x82

10028 P 202x18 HF ST 2M 35 2700 622x196x82

10026 P 201x36 HF 2M 36 3350 1231x156x82

10033 P 203x18 HF 2M 55 4050 622x596x82

10027 P 201x58 HF 2M 55 5200 1531x156x82

10034 P 204x18 HF 2M 74 5400 622x596x82

10029 P 202x36 HF ST 2M 71 6700 1231x196x82

10031 P 202x36 HF 2M 71 6700 1231x270x82

10030 P 202x58 HF ST 2M 109 10400 1531x196x82

10032 P 202x58 HF 2M 109 10400 1531x270x82

P 200 Fluo

L<1000 cd/m² 65°

E>63%

Average luminance <200 cd/m² for radial angles >65°.1000W - Average luminance <65 cd/m² for radial angles >°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 107: 3F Filippi  "General catalogue 2016"

104

P 200 2MG

Code 10270

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

10265 P 201x18 HF 2MG 19 1350 622x156x82

10268 P 202x18 HF ST 2MG 35 2700 622x196x82

10266 P 201x36 HF 2MG 36 3350 1231x156x82

10273 P 203x18 HF 2MG 55 4050 622x596x82

10267 P 201x58 HF 2MG 55 5200 1531x156x82

10274 P 204x18 HF 2MG 74 5400 622x596x82

10269 P 202x36 HF ST 2MG 71 6700 1231x196x82

10271 P 202x36 HF 2MG 71 6700 1231x270x82

10270 P 202x58 HF ST 2MG 109 10400 1531x196x82

10272 P 202x58 HF 2MG 109 10400 1531x270x82

P 200 Fluo

L<1000 cd/m² 65°

E>71%

Average luminance <200 cd/m² for radial angles >65°.1000W - Average luminance <65 cd/m² for radial angles >°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 108: 3F Filippi  "General catalogue 2016"

105Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

P 200 2US

Code 10090

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

10085 P 201x18 HF 2US 19 1350 622x156x82

10088 P 202x18 HF ST 2US 35 2700 622x196x82

10086 P 201x36 HF 2US 36 3350 1231x156x82

10093 P 203x18 HF 2US 55 4050 622x596x82

10087 P 201x58 HF 2US 55 5200 1531x156x82

10094 P 204x18 HF 2US 74 5400 622x596x82

10089 P 202x36 HF ST 2US 71 6700 1231x196x82

10091 P 202x36 HF 2US 71 6700 1231x270x82

10090 P 202x58 HF ST 2US 109 10400 1531x196x82

10092 P 202x58 HF 2US 109 10400 1531x270x82

P 200 Fluo

L<1000 cd/m² 65°

E>62%

Average luminance <200 cd/m² for radial angles >65°.1000W - Average luminance <65 cd/m² for radial angles >°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 109: 3F Filippi  "General catalogue 2016"

106

P 200 Fluo IP54Ceiling luminaire with high level of ingress protection

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsHousing in white painted steel with sealing gasket.White painted flow recuperator, high reflection.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, hinged opening.SP transparent PMMA diffuser, prismatic, anti-glare, locked to the pre-painted white aluminium perimeter frame, hinged opening.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.4x14-24 version in twin-circuit execution.In compliance with EN 60598-1.

Dimensions

Applications

Particularly suitable for environments where protection against water and dust is required, such as hospitals, pharmaceutical and chemical laboratories.The Multiwatt wiring also makes it suitable following changes in previously intended use of the environment.In environments with foodstuffs or machines with moving parts, with considerable sudden temperature changes, and in general in any environments requiring total protection against falling fragments, use the P 200 T5 IP54 RSP PC version (polycarbonate diffuser and flux recuperator) on request or specific IP65 luminaires with laminated glass and suitable frame.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

On request

• RSP PC version with polycarbonate diffuser

• fuse accessory (on page 472)• wiring: dimmable, twin-circuit,

emergency

L

H

H

A

Page 110: 3F Filippi  "General catalogue 2016"

107Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

P 200 Fluo RSP IP54

Code 10572

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

10574 P 204x14-24 T5 HF DA RSP IP54 62-98 4800-7000 596x596x82

10572 P 202x28-54 T5 HF RSP IP54 60-114 5200-8900 1196x270x82

E>60%

SP flat diffuser in transparent PMMA, outside prismatic, anti-glare.

P 200 Fluo RVS IP54

Code 10546

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

10548 P 204x14-24 T5 HF DA RVS IP54 62-98 4800-7000 596x596x82

10546 P 202x28-54 T5 HF RVS IP54 60-114 5200-8900 1196x270x82

P 200 Fluo IP54

E>60%

Moulded anti-glare glass, tempered.

Page 111: 3F Filippi  "General catalogue 2016"

108

Zero 3F LEDLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Average luminance <3000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted pressed steel.Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: recreational, transit areas, corridors, schools, stairwells.Environments requiring a high level of protection, high levels of light, source shielding and simplified cleaning.Luminaire optimised to replace previously installed Zero 3F Fluorescent luminaires thanks to the same fixing points.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• impact protection wire guards• wiring: dimmable, emergency wiring

(9W-18W excluded)• IP54 versions

A

H

L

H

Page 112: 3F Filippi  "General catalogue 2016"

109Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Zero 3F LED Squadred

Code 12508

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12507 03F LED 4x6W 350x350 30 3588 350x350x68

12508 03F LED 4x9W 640x640 42 5547 640x640x68

L<3000 cd/m² 65°

E=100%

9W - Average luminance <3000 cd/m² for radial angles >65°.Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Zero 3F LED Rectangular

Code 12505

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12491 03F LED 1x9W L640 10 1386 640x110x85

12493 03F LED 1x18W L1250 20 2769 1250x110x85

12501 03F LED 2x9W L640 20 2780 640x210x68

12495 03F LED 1x22W L1550 25 3460 1550x110x85

12503 03F LED 2x18W L1250 40 5566 1250x210x68

12505 03F LED 2x22W L1550 50 6953 1550x210x68

Zero 3F LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Page 113: 3F Filippi  "General catalogue 2016"

110

Zero 3F FluoCeiling luminaire

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.

Mechanical characteristicsHousing in white painted pressed steel.Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Electrical characteristicsEEI B2 low loss starter wiring, 230V-50Hz, power factor correction.In compliance with EN 60598-1.

Dimensions

Applications

Environments: recreational, transit areas, corridors, schools, stairwells.Environments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.

On request

• impact protection wire guards• fuse accessory (on page 472)• wiring: electronic, dimmable, emergency• polycarbonate versions• IP54 versions• luminaire suitable for installation on

flammable surfaces

A

H

L

H

Page 114: 3F Filippi  "General catalogue 2016"

111Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Zero 3F Squadred

Code 1446

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Square version 350x350 - Starter EEI B2 - Lamps not included

1443 03F 1x22 28 1250 350x350x68

1444 03F 1x32 38 2050 350x350x68

Square version 450x450 - Starter EEI B2 - Lamps not included

1445 03F 2x32+40 88 4950 450x450x68

Square version 640x640 - Starter EEI B2 - Lamps not included

1446 03F 4x18 86 5400 640x640x68

E>64%

Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Zero 3F R

Code 1440

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Starter EEI B2 - Lamps not included

1435 03F 1x18 26 1350 640x110x85

1438 03F 2x18 43 2700 640x210x68

1436 03F 1x36 43 3350 1250x110x85

1437 03F 1x58 67 5200 1550x110x85

1439 03F 2x36 87 6700 1250x210x68

1441 03F 3x36 129 10050 1250x300x68

1440 03F 2x58 134 10400 1550x210x68

Zero 3F Fluo

E>65%

Diffuser in transparent PMMA, multilenticular, anti-glare, injection moulded.

Page 115: 3F Filippi  "General catalogue 2016"

112

New

3F Quadro LEDLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in galvanized steel, powder-coated in white epoxy-polyester.Quick connection in polycarbonate M20x1.5 cable gland for access to the terminal block.Total flux recuperator for wide distribution, in specular aluminium with titaniummagnesium surface treatment, non-iridescent.SP transparent PMMA diffuser, prismatic, anti-glare, locked to the pre-painted white aluminium perimeter frame, hinged opening.Fixing brackets.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Quick connection.It is no longer necessary to open the luminaires to connect them: with a simple and fast operation, just take the terminal block out of the top slot and make the connection.Twin-circuit.

Dimensions

Applications

Environments: commercial, exhibition areas, industrial.Environments where high levels of light are required.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• wiring: dimmable, single-circuit

Accessories

Accessories on page 113.

H

A = L

Page 116: 3F Filippi  "General catalogue 2016"

113Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

3F Quadro LED

Code 4702

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

4702 3F Quadro LED 100W DA CR SP IP43 110 13254 620x620x180

3F Quadro LED

E=100%

Total flux recuperator for wide distribution, in specular aluminium with titaniummagnesium surface treatment, non-iridescent.SP transparent methacrylate diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame, hinged opening.

Accessories

Ceiling-mounted bracket in hot-galvanised steel.

Code Item

A0213 Ceiling-mounted bracket

Page 117: 3F Filippi  "General catalogue 2016"

114

Barraluce P LEDLED channel system for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsCorps in natural anodised extruded aluminium.Removable gear-tray, functions as flux recuperator, in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.1+1 wiring in twincircuit.Upper power entry near an end cap.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.

Dimensions

Applications

Environments: with VDTs, meeting rooms, offices.Environments: architectural, commercial, staterooms, banks.Environments where dynamic, soft and diffuse light is required for optimal visual comfort.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• wiring: dimmable, emergency• possibility to create lighting corners

Accessories

Accessories on page 122.

L

L A

H

Single

Channel

Page 118: 3F Filippi  "General catalogue 2016"

115Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Barraluce P LED Opal - Channel

Code 12797

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12795 Barraluce P 1x30W LED OP 5P L1466 34 2830 1466x99x100

12797 Barraluce P 1+1x30W LED OP 5P L2932 68 5661 2932x99x100

E=100%

Luminaire for continuous channel installation (end caps not included).OP opal methacrylate flat diffuser, anti-glare.

Barraluce P LED Opal - Single

Code 12787

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12787 Barraluce P 1x30W LED OP L1471 34 2830 1471x99x100

12789 Barraluce P 1+1x30W LED OP L2937 68 5661 2937x99x100

Barraluce P LED

E=100%

Luminaire for standalone installation with aluminium end caps.OP opal methacrylate flat diffuser, anti-glare.

Page 119: 3F Filippi  "General catalogue 2016"

116

Barraluce P LED SP - Channel

Code 12781

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12779 Barraluce P 1x30W LED SP 5P L1466 34 3188 1466x99x100

12781 Barraluce P 1+1x30W LED SP 5P L2932 68 6377 2932x99x100

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Luminaire for continuous channel installation (end caps not included).SP flat diffuser in PMMA transparent prismatic methacrylate, anti-glare.

Barraluce P LED SP - Single

Code 12771

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

12771 Barraluce P 1x30W LED SP L1471 34 3188 1471x99x100

12773 Barraluce P 1+1x30W LED SP L2937 68 6377 2937x99x100

Barraluce P LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Luminaire for standalone installation with aluminium end caps.SP flat diffuser in PMMA transparent prismatic methacrylate, anti-glare.

Page 120: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 121: 3F Filippi  "General catalogue 2016"

118

Barraluce P Opal FluoFluorescent channel system with high visual comfort

Construction characteristics

Illuminotechnical characteristicsDirect diffused distribution.

Mechanical characteristicsCorps in natural anodised extruded aluminium.Removable gear-tray functioning as flow recuperator, in high reflection white painted steel.OP flat diffuser in opal PMMA.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Upper power entry near an end cap.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.Lamps excluded.

Dimensions

Applications

Environments: architectural, commercial, staterooms, banks, shops, offices.Environments where dynamic, soft and diffuse light is required for optimal visual comfort.

On request

• micro-prismatic diffuser• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 122.

A

HL

L

L

L

Single

IFC 1x

IFC 1+1x

IC

Page 122: 3F Filippi  "General catalogue 2016"

119Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Barraluce P Opal - Channel

Code 172012

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

IFC Start/End Channel - Electronic MultiWatt EEI A2 - Lamps not included

172005 Barraluce P 1x28-54 T5 HF OP IFC 5P 31-58 2600-4450 1122x99x100

172012 Barraluce P 1x35-49-80 T5 HF OP IFC 5P 38-53-86 3300-4300-6150 1422x99x100

172019 Barraluce P 1+1x28-54 T5 HF OP IFC 5P 60-114 5200-8900 2191x99x100

172026 Barraluce P 1+1x35-49-80 T5 HF OP IFC 5P 76-106-170 6600-8600-12300 2791x99x100

IC Channel Intermediate - Electronic MultiWatt EEI A2 - Lamps not included

172507 Barraluce P 1+1x28-54 T5 HF OP IC 5P 60-114 5200-8900 2138x99x100

172514 Barraluce P 1+1x35-49-80 T5 HF OP IC 5P 76-106-170 6600-8600-12300 2738x99x100

E>50%

Luminaire for continuous channel installation (end caps not included), with light continuity even in the junction.OP opal methacrylate flat diffuser, anti-glare.

Barraluce P Opal - Single

Code 170221

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

170215 Barraluce P 1x28-54 T5 HF OP 31-58 2600-4450 1184x99x100

170221 Barraluce P 1x35-49-80 T5 HF OP 38-53-86 3300-4300-6150 1484x99x100

Barraluce P Opal Fluo

E>50%

Luminaire for standalone installation with aluminium end caps.OP opal methacrylate flat diffuser, anti-glare.

Page 123: 3F Filippi  "General catalogue 2016"

120

Barraluce P 2MG FluoFluorescent channel system with luminance control

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Average luminance <1000 cd/m² for radial angles >65°.

Mechanical characteristicsCorps in natural anodised extruded aluminium.Removable gear-tray in white painted steel.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, attached to louvre.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Upper power entry near an end cap.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.Lamps excluded.

Dimensions

Applications

Environments: architectural, commercial, staterooms, with VDTs, banks, shops, offices.Environments where demanding visual tasks are performed and comfortable lighting is required.

On request

• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 122.

A

HL

L

L

L

Single

IFC 1x

IFC 1+1x

IC

Page 124: 3F Filippi  "General catalogue 2016"

121Datasheets, product updates and specifications on our website: www.3f-filippi.com

Surf

ace lum

inaires

and

susp

ensio

ns

Barraluce P 2MG - Channel

Code 173430

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

IFC Start/End Channel - Electronic MultiWatt EEI A2 - Lamps not included

173423 Barraluce P 1x28-54 T5 HF 2MG IFC 5P 31-58 2600-4450 1175x99x105

173430 Barraluce P 1x35-49-80 T5 HF 2MG IFC 5P 38-53-86 3300-4300-6150 1475x99x105

173437 Barraluce P 1+1x28-54 T5 HF 2MG IFC 5P 60-114 5200-8900 2346x99x105

173444 Barraluce P 1+1x35-49-80 T5 HF 2MG IFC 5P 76-106-170 6600-8600-12300 2946x99x105

IC Channel Intermediate - Electronic MultiWatt EEI A2 - Lamps not included

173589 Barraluce P 1+1x28-54 T5 HF 2MG IC 5P 60-114 5200-8900 2342x99x105

173590 Barraluce P 1+1x35-49-80 T5 HF 2MG IC 5P 76-106-170 6600-8600-12300 2942x99x105

L<1000 cd/m² 65°

E>75%

Luminaire for continuous channel installation (end caps not included), with light continuity even in the junction.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Barraluce P 2MG - Single

Code 171543

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

171536 Barraluce P 1x28-54 T5 HF 2MG 31-58 2600-4450 1184x99x105

171543 Barraluce P 1x35-49-80 T5 HF 2MG 38-53-86 3300-4300-6150 1484x99x105

Barraluce P 2MG Fluo

L<1000 cd/m² 65°

E>75%

Luminaire for standalone installation with aluminium end caps.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 125: 3F Filippi  "General catalogue 2016"

122

Suspensions for Barraluce P with regulator, galvanized steel cable of 2 mm diameter, load 25 kg.

Code Item

A0693 New Suspension with adjustment for Barraluce P - 1m

A0694 New Suspension with adjustment for Barraluce P - 2 m

A0695 New Suspension with adjustment for Barraluce P - 3 m

A0696 New Suspension with adjustment for Barraluce P - 4 m

A0697 New Suspension with adjustment for Barraluce P - 5 m

A0698 New Suspension with adjustment for Barraluce P - 6 m

Terminal block (plug/socket) with irreversible snap-in double clamp, for power-supply connection at beginning and end of the channel, 5 poles.

Code Item

A02484 5P socket/plug terminal block Beginning/End Channel

Pair of end caps for channels, in grey painted aluminium, with screws for fixing to housing, always required.Thickness: 2 mm each cap.

Code Item

A01434 Pair of end caps for Barraluce L channels with diffuser

Linear connecting elements in hotgalvanised steel with grub screws for fast and rigid installation.

Code Item

A01423 Linear connecting elements Barraluce

Accessories

Barraluce P

Concealed sliding bracket in galvanized steel for free positioning, with locking screws.

Code Item

A01429 Sliding bracket for Barraluce P

Page 126: 3F Filippi  "General catalogue 2016"

Surf

ace lum

inaires

and

susp

ensio

ns

Page 127: 3F Filippi  "General catalogue 2016"
Page 128: 3F Filippi  "General catalogue 2016"

125

Recessed

lum

inaires

News and updates available on: www.3f-filippi.com > Products > Recessed luminaires

Recessed Luminaires

126 Lucequadro126 Lucequadro LED LED •

130 Lucequadro LED VDT LED •

184 L 350184 L 350 LED LED • with brackets

186 L 350 Fluo Fluo • with brackets

208 L 560208 L 560 LED LED •

210 L 560 Fluo Fluo •

216 L 580216 L 580 LED IP54V LED •

218 L 580 Fluo IP54 Fluo •

192 L 390192 New L 390 LED LED •

194 L 390 LED HCL LED •

140 3F Dodeca140 3F Dodeca 220 Fluo •

144 3F Dodeca 220 AC Fluo •

148 3F Dodeca 300 Fluo •

154 L 320154 New L 320 LED LED • with brackets

158 New L 320 LED Diffused light LED • with brackets

160 New L 320 LED HCL LED • with brackets

162 L 320 LED Sensor LED • with brackets

164 New L 320 LED Wall Washer LED • with brackets

166 L 320 Fluo Fluo • with brackets

180 L 320 Fluo Decorative Border Fluo • with brackets

134 Galassia134 Galassia 220 LED •

190 L 350 Fluo R90190 L 350 Fluo R90 Fluo • with brackets

198 L 400198 L 400 Fluo Fluo •

204 L 450204 L 450 Fluo Fluo •

224 L 590224 L 590 Fluo IP65 Fluo •

228 Barraluce L228 Barraluce L LED LED •

232 Barraluce L Opal Fluo Fluo •

234 Barraluce L 2MG Fluo Fluo •

Page Product Source Lay-installation Pull-up installation Sterile environments Slat ceiling

Page 129: 3F Filippi  "General catalogue 2016"

126

Lucequadro LEDCompact recessed LED luminaire for high energy efficiency systems and high visual comfort

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in white painted steel.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.Flow recuperator in specular aluminium with superficial titanium-magnesium treatment, non-iridescent.Lock-in mounting of the glass/PMMA in the lateral seats in specular aluminium.Fixing brackets in galvanised steel, supplied.

Electrical characteristicsWiring on a separate unit.Electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.EP maintained emergency wiring, 3hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Environments: commercial, exhibition areas, transit areas, halls, shops, great halls, display windows.

Source characteristics

• Compact LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 3 compliant.

On request

• asymmetric louvre• LED module, CCT nominal color

temperature 3000 K, color rendering index CRI >90

• wiring: dimmable• fluorescent version• IP54 version• ceiling version

Accessories

Accessories on page 132.

A = L

H

Page 130: 3F Filippi  "General catalogue 2016"

127Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Lucequadro LED VOP

Code 36584

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

36581 Lucequadro LED 2000 VOP 18.7 1272 235x235x116

36584 Lucequadro LED 3000 VOP 27.5 1673 235x235x116

EP emergency, fuse

36582 Lucequadro LED 2000 EP VOP 18.7 1272 235x235x116

36585 Lucequadro LED 3000 EP VOP 27.5 1673 235x235x116

E=100%

Glazed VOP opal glass, tempered, non-combustible, thickness 4 mm.

Lucequadro LED VS

Code 36578

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

36575 Lucequadro LED 2000 VS 18.7 2027 235x235x116

36578 Lucequadro LED 3000 VS 27.5 2668 235x235x116

EP emergency, fuse

36576 Lucequadro LED 2000 EP VS 18.7 2027 235x235x116

36579 Lucequadro LED 3000 EP VS 27.5 2668 235x235x116

Lucequadro LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm.

Page 131: 3F Filippi  "General catalogue 2016"

128

Lucequadro LED SOP

Code 36590

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

36587 New Lucequadro LED 2000 SOP 18.7 1980 235x235x116

36590 New Lucequadro LED 3000 SOP 27.5 2606 235x235x116

EP emergency, fuse

36588 New Lucequadro LED 2000 EP SOP 18.7 1980 235x235x116

36591 New Lucequadro LED 3000 EP SOP 27.5 2606 235x235x116

Lucequadro LED

E=100%

SOP opal methacrylate flat diffuser, anti-glare.

Page 132: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 133: 3F Filippi  "General catalogue 2016"

130

Lucequadro LED VDTCompact recessed LED luminaire for high energy efficiency systems and high visual comfort

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in white painted steel.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.2MG parabolic louvre with blades and V-element closed at the top, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.Fixing brackets in galvanised steel, supplied.

Electrical characteristicsWiring on a separate unit.Electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: architectural, commercial, staterooms, with VDTs, banks, shops, offices, meeting rooms, auditoriums.Environments where demanding visual tasks are performed and comfortable lighting is required.

Source characteristics

• Compact LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 3 compliant.

On request

• LED module, CCT nominal color temperature 3000 K, color rendering index CRI >90

• wiring: dimmable• fluorescent version• ceiling version

Accessories

Accessories on page 132.

H

A = L

25

66

25

Page 134: 3F Filippi  "General catalogue 2016"

131Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Lucequadro LED VDT

Code 36601

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

36601 Lucequadro LED 4000 2MG VDT 34.4 3342 321x321x165

Lucequadro LED VDT

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 135: 3F Filippi  "General catalogue 2016"

132

Accessories

Lucequadro

Pair of reinforcing brackets for false ceilings in mineral fibre, metal and plasterboard, height 20 mm.

Code Item

A0189 Reinforcing bracket Lucequadro for pan./plast.

Page 136: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 137: 3F Filippi  "General catalogue 2016"

134

Galassia 220Compact recessed LED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing and fixing brackets in galvanized steel.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.

Electrical characteristicsWiring on a separate unit.Electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.EP maintained emergency wiring, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Environments: architectural, commercial, exhibition areas, transit areas, corridors, shops, display windows.In false ceilings with narrow voids.

Source characteristics

• Compact LED module, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 3 compliant.

On request

• asymmetric louvre• LED module, CCT nominal color

temperature 3000 K, color rendering index CRI >90

• wiring: dimmable• ceiling version

Accessories

Accessories on page 139.

HH

Ø Ø

2000 -3000 lm 4000 lm

Page 138: 3F Filippi  "General catalogue 2016"

135Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Galassia 220 VT

Code 37802

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37759 Galassia 220 LED 2000 VT 18.7 1877 221x103

37802 Galassia 220 LED 3000 VT 27.5 2471 221x103

37834 Galassia 220 LED 4000 VT 34.4 3255 221x151

EP emergency, fuse

37761 Galassia 220 LED 2000 EP VT 18.7 1877 221x103

37804 Galassia 220 LED 3000 EP VT 27.5 2471 221x103

E=100%

2000 - Average luminance <1000 cd/m² for radial angles >65°.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Circular anti-glare LED shielding lens in opal PMMA for good visual comfort.VT transparent glass, tempered, not flammable, locked and in line with the trim.It does not allow the access of the insects into the luminous compartment, avoiding unpleasant visual effects and extraordinary maintenance.

Galassia 220

Code 37793

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37750 Galassia 220 LED 2000 18.7 1977 221x103

37793 Galassia 220 LED 3000 27.5 2602 221x103

37830 Galassia 220 LED 4000 34.4 3429 221x151

EP emergency, fuse

37752 Galassia 220 LED 2000 EP 18.7 1977 221x103

37795 Galassia 220 LED 3000 EP 27.5 2602 221x103

Galassia 220

E=100%

2000 - Average luminance <1000 cd/m² for radial angles >65°.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Circular anti-glare LED shielding lens in opal PMMA for good visual comfort.

Page 139: 3F Filippi  "General catalogue 2016"

136

Galassia 220 VOP

Code 37811

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37768 Galassia 220 LED 2000 VOP 18.7 1294 221x103

37811 Galassia 220 LED 3000 VOP 27.5 1703 221x103

37842 Galassia 220 LED 4000 VOP 34.4 2244 221x151

EP emergency, fuse

37770 Galassia 220 LED 2000 EP VOP 18.7 1294 221x103

37813 Galassia 220 LED 3000 EP VOP 27.5 1703 221x103

E=100%

Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Glazed OP opal glass, tempered, non-combustible, locked in line with the trim.It does not allow the access of the insects into the luminous compartment, avoiding unpleasant visual effects and extraordinary maintenance.

Galassia 220 VS

Code 37820

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37777 Galassia 220 LED 2000 VS 18.7 2103 221x103

37820 Galassia 220 LED 3000 VS 27.5 2767 221x103

37838 Galassia 220 LED 4000 VS 34.4 3646 221x151

EP emergency, fuse

37779 Galassia 220 LED 2000 EP VS 18.7 2103 221x103

37822 Galassia 220 LED 3000 EP VS 27.5 2767 221x103

Galassia 220

E=100%

2000 - Average luminance <3000 cd/m² for radial angles >65°.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked and in line with the trim.It does not allow the access of the insects into the luminous compartment, avoiding unpleasant visual effects and extraordinary maintenance.

Page 140: 3F Filippi  "General catalogue 2016"

137Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Galassia 220 AB VS

Code 37587

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37551 Galassia 220 LED AB 2000 VS 18.7 2103 226x103

37587 Galassia 220 LED AB 3000 VS 27.5 2767 226x103

37604 Galassia 220 LED AB 4000 VS 34.4 3646 226x151

EP emergency, fuse

37553 Galassia 220 LED AB 2000 EP VS 18.7 2103 226x103

37589 Galassia 220 LED AB 3000 EP VS 27.5 2767 226x103

Galassia 220

E=100%

2000 - Average luminance <3000 cd/m² for radial angles >65°.AB trim in white moulded Bayblend.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked and in line with the trim.It does not allow the access of the insects into the luminous compartment, avoiding unpleasant visual effects and extraordinary maintenance.

Page 141: 3F Filippi  "General catalogue 2016"

138

Galassia 220 AB VOP

Code 37578

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

37542 Galassia 220 LED AB 2000 VOP 18.7 1294 226x103

37578 Galassia 220 LED AB 3000 VOP 27.5 1703 226x103

37608 Galassia 220 LED AB 4000 VOP 34.4 2244 226x151

EP emergency, fuse

37544 Galassia 220 LED AB 2000 EP VOP 18.7 1294 226x103

37580 Galassia 220 LED AB 3000 EP VOP 27.5 1703 226x103

Galassia 220

E=100%

AB trim in white moulded Bayblend.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Glazed OP opal glass, tempered, non-combustible, locked in line with the trim.It does not allow the access of the insects into the luminous compartment, avoiding unpleasant visual effects and extraordinary maintenance.

Page 142: 3F Filippi  "General catalogue 2016"

139Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Anti-rotation adapter for grilled ceiling with closing mats (always suggested to avoid stray light).Adapter made in steel - white color, RAL 9010.

Code Item

A0204 Grid bracket h40mm - for luminaire D.220

A01523 Grid bracket h50mm - for luminaire D.220

Bracket size 289x289 mm for 50x50, 75x75, 100x100 mesh, slat 10 mm thick.

Reinforcing bracket for metal panels 600x600 with concealed structure, in hot-galvanized steel.

Code Item

A0214 Metal pan. reinforcing bracket (3F Dodeca 220)

Accessories

Galassia

Reinforcing bracket for panels 600x600, 600x1200 with exposed structure, in hot-galvanised steel.

Code Item

A0202 False ceiling bracket - for luminaire D.220

Page 143: 3F Filippi  "General catalogue 2016"

140

3F Dodeca 220Circular recessed luminaire

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsPolycarbonate housing (for versions with absorbed power up to 40W).Galvanized steel housing (for versions with absorbed power over 40W).Fixing brackets in galvanised steel.Trim in light grey polycarbonate.Dodecagonal louvre made up with aluminium segments on a polycarbonate support.

Electrical characteristicsWiring on a separate unit.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Accessories

Accessories on page 152.

Applications

Use of diffusers or glass covers provides IP44 protection for the exposed part and allows application in rooms with protection requirements such as laboratories or service areas.2MG, 2S versionsEnvironments: with VDTs, auditoriums, meeting rooms.Environments where soft diffuse light is required for optimal visual comfort.2MG VS versionEnvironments: commercial, exhibition areas, shops, display windows.Version specifically suitable for canteens, hospitals and environments with foodstuffs (thanks to anti-insects protection).

Source characteristics

• Fluorescent compact lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• 42W amalgam lamps.

On request

• asymmetric lighting distribution for the single-lamp version

• lamps in different powers or colour temperatures

• MultiWatt ballast in case of change of use of the room

• central crossshaped louvre for complete shielding of the lamp

• opal glass and PMMA• fuse accessory (on page 472)• wiring: dimmable, twin-circuit, class II,

emergency with different characteristics, ENP emergency and/or night light

• emergency inhibition

Ø

H

Page 144: 3F Filippi  "General catalogue 2016"

141Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

3F Dodeca 220 2MG

Code 3901

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3897 3F Dodeca 220 1x18 CD HF 2MG 19 1200 222x158

3898 3F Dodeca 220 1x26 CD HF 2MG 26 1800 222x158

3900 3F Dodeca 220 2x18 CD HF 2MG 37 2400 222x158

3905 3F Dodeca 220 1x42 CT HF 2MG 44 3200 222x158

3901 3F Dodeca 220 2x26 CD HF 2MG 53 3600 222x158

EP emergency, fuse - Lamps supplied

3907 3F Dodeca 220 1x18 CD HF EP 2MG 19 1200 222x158

3908 3F Dodeca 220 1x26 CD HF EP 2MG 26 1800 222x158

3910 3F Dodeca 220 2x18 CD HF EP 2MG 37 2400 222x158

3915 3F Dodeca 220 1x42 CT HF EP 2MG 44 3200 222x158

3911 3F Dodeca 220 2x26 CD HF EP 2MG 53 3600 222x158

3F Dodeca 220

L<200 cd/m² 65°

E>64%

Average luminance <200 cd/m² for radial angles >65°.2MG dodecagonal optic composed of aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.

Page 145: 3F Filippi  "General catalogue 2016"

142

3F Dodeca 220 2MG VS

Code 3768

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3768 3F Dodeca 220 1x42 CT HF 2MG VS 44 3200 222x158

EP emergency, fuse - Lamps supplied

3770 3F Dodeca 220 1x42 CT HF EP 2MG VS 44 3200 226x158

E>63%

2MG dodecagonal optic composed of aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked and in line with the trim.

3F Dodeca 220 2S

Code 3945

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3938 3F Dodeca 220 1x18 CD HF 2S 19 1200 222x158

3940 3F Dodeca 220 1x26 CD HF 2S 26 1800 222x158

3944 3F Dodeca 220 2x18 CD HF 2S 37 2400 222x158

3942 3F Dodeca 220 1x42 CT HF 2S 44 3200 222x158

3945 3F Dodeca 220 2x26 CD HF 2S 53 3600 222x158

EP emergency, fuse - Lamps supplied

3948 3F Dodeca 220 1x18 CD HF EP 2S 19 1200 222x158

3950 3F Dodeca 220 1x26 CD HF EP 2S 26 1800 222x158

3954 3F Dodeca 220 2x18 CD HF EP 2S 37 2400 222x158

3952 3F Dodeca 220 1x42 CT HF EP 2S 44 3200 222x158

3955 3F Dodeca 220 2x26 CD HF EP 2S 53 3600 222x158

3F Dodeca 220

L<200 cd/m² 65°

E>59%

Average luminance <200 cd/m² for radial angles >65°.2S dodecagonal optic made of aluminum foil half-mirror, antiglare, mounted on a polycarbonate support.

Page 146: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 147: 3F Filippi  "General catalogue 2016"

144

3F Dodeca 220 ACLow-height circular recessed luminaire

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.

Mechanical characteristicsHousing in galvanised steel.Fixing brackets in galvanised steel.Trim in light grey polycarbonate.

Electrical characteristicsWiring on a separate unit.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Accessories

Accessories on page 152.

Applications

In false ceilings with narrow voids.Environments: commercial, exhibition areas, shops, display windows.Use of diffusers or glass covers provides IP44 protection for the exposed part and allows application in rooms with protection requirements such as laboratories or service areas.2MG VDT versionEnvironments with VDTs.Environments where demanding visual tasks are performed and comfortable lighting is required.2MG VS versionVersion specifically suitable for canteens, hospitals and environments with foodstuffs (thanks to anti-insects protection).

Source characteristics

• Fluorescent compact lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• parabolic louvre 2S• asymmetric lighting distribution for the

single-lamp version• lamps in different powers or colour

temperatures• MultiWatt ballast in case of change of

use of the room• opal glass and PMMA• fuse accessory (on page 472)• wiring: dimmable, twin-circuit, class II,

emergency with different characteristics, ENP emergency and/or night light

• emergency inhibition

H

Ø

Page 148: 3F Filippi  "General catalogue 2016"

145Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

3F Dodeca 220 AC 2MG VDT

Code 36205

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

36202 3F Dodeca 220 AC 1x26 CD HF 2MG VDT 26 1800 222x100

36205 3F Dodeca 220 AC 2x26 CD HF 2MG VDT 53 3600 222x100

EP emergency, fuse - Lamps supplied

36231 3F Dodeca 220 AC 1x26 CD HF EP 2MG VDT 26 1800 222x100

36234 3F Dodeca 220 AC 2x26 CD HF EP 2MG VDT 53 3600 222x100

L<1000 cd/m² 65

E>51%

Average luminance <1000 cd/m² for radial angles >65°.2MG VDT dodecagonal optic with high shielding and central cross and aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.

3F Dodeca 220 AC 2MG

Code 3088

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3084 3F Dodeca 220 AC 1x18 CD HF 2MG 19 1200 222x100

3085 3F Dodeca 220 AC 1x26 CD HF 2MG 26 1800 222x100

3087 3F Dodeca 220 AC 2x18 CD HF 2MG 37 2400 222x100

3088 3F Dodeca 220 AC 2x26 CD HF 2MG 53 3600 222x100

EP emergency, fuse - Lamps supplied

3094 3F Dodeca 220 AC 1x18 CD HF EP 2MG 19 1200 222x100

3095 3F Dodeca 220 AC 1x26 CD HF EP 2MG 26 1800 222x100

3097 3F Dodeca 220 AC 2x18 CD HF EP 2MG 37 2400 222x100

3098 3F Dodeca 220 AC 2x26 CD HF EP 2MG 53 3600 222x100

3F Dodeca 220 AC

E>63%

2MG dodecagonal optic composed of aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.

Page 149: 3F Filippi  "General catalogue 2016"

146

3F Dodeca 220 AC 2MG VS

Code 3177

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3174 3F Dodeca 220 AC 1x26 CD HF 2MG VS 26 1800 226x100

3176 3F Dodeca 220 AC 2x18 CD HF 2MG VS 37 2400 226x100

3177 3F Dodeca 220 AC 2x26 CD HF 2MG VS 53 3600 226x100

EP emergency, fuse - Lamps supplied

3181 3F Dodeca 220 AC 1x26 CD HF EP 2MG VS 26 1800 226x100

3183 3F Dodeca 220 AC 2x18 CD HF EP 2MG VS 37 2400 226x100

3184 3F Dodeca 220 AC 2x26 CD HF EP 2MG VS 53 3600 226x100

3F Dodeca 220 AC

E>33%

2MG dodecagonal optic composed of aluminum foil mirror, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked and in line with the trim.

Page 150: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 151: 3F Filippi  "General catalogue 2016"

148

3F Dodeca 300Circular recessed luminaire

Construction characteristics

Illuminotechnical characteristicsSymmetric lighting distribution, asymmetric lighting distribution can be achieved in the single-lamp version by dislocating the lamp.

Mechanical characteristicsHousing in galvanised steel.Fixing brackets in galvanised steel.Trim in light grey polycarbonate.Dodecagonal louvre made up with aluminium segments on a polycarbonate support.IP23-44 protection degree for the exposed part.

Electrical characteristicsWiring on a separate unit.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Source characteristics

• Fluorescent compact lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• 32-42W amalgam lamps.

Dimensions

Applications

The use of glass covers provides IP44 protection degree in the exposed part and allows application in rooms with protection requirements such as laboratories or service areas.2MG, 2S single-lamp versionsEnvironments: architectural, staterooms, with VDTs, auditoriums, meeting rooms, offices.Environments with exacting visual tasks, where diffused soft light for optimum visual comfort is required.2MG, 2S twin-lamp versionsEnvironments: commercial, exhibition areas.Environments where high levels of light are required.2MG SK versionEnvironments with VDTs.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.2MG VS versionVersion specifically suitable for canteens, hospitals and environments with foodstuffs (thanks to anti-insects protection).

On request

• asymmetric lighting distribution• lamps in different powers or colour

temperatures• MultiWatt ballast in case of change of

use of the room• opal glass• fuse accessory (on page 472)• wiring: dimmable, twin-circuit, class II,

emergency with different characteristics, ENP emergency and/or night light

• three-lamp wiring fitted (e.g. 2x32 CT+1x26 CT)

• emergency inhibition• ceiling version

Accessories

Accessories on page 152.

Ø

H

Page 152: 3F Filippi  "General catalogue 2016"

149Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

3F Dodeca 300 2MG

Code 3563

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3561 3F Dodeca 300 1x26 CD HF 2MG 26 1800 303x188

3562 3F Dodeca 300 1x32 CT HF 2MG 34 2400 303x188

3563 3F Dodeca 300 1x42 CT HF 2MG 44 3200 303x188

3566 3F Dodeca 300 2x26 CD HF 2MG 53 3600 303x188

3567 3F Dodeca 300 2x32 CT HF 2MG 69 4800 303x188

3568 3F Dodeca 300 2x42 CT HF 2MG 91 6400 303x188

EP emergency, fuse - Lamps supplied

3570 3F Dodeca 300 1x26 CD HF EP 2MG 26 1800 303x188

3571 3F Dodeca 300 1x32 CT HF EP 2MG 34 2400 303x188

3572 3F Dodeca 300 1x42 CT HF EP 2MG 44 3200 303x188

3575 3F Dodeca 300 2x26 CD HF EP 2MG 53 3600 303x188

3576 3F Dodeca 300 2x32 CT HF EP 2MG 69 4800 303x188

3577 3F Dodeca 300 2x42 CT HF EP 2MG 91 6400 303x188

3F Dodeca 300

L<200 cd/m² 60°

E>85%

Average luminance <200 cd/m² for radial angles >60°.2MG dodecagonal optic composed of aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.

Page 153: 3F Filippi  "General catalogue 2016"

150

3F Dodeca 300 2S

Code 3608

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3606 3F Dodeca 300 1x26 CD HF 2S 26 1800 303x188

3607 3F Dodeca 300 1x32 CT HF 2S 34 2400 303x188

3608 3F Dodeca 300 1x42 CT HF 2S 44 3200 303x188

3611 3F Dodeca 300 2x26 CD HF 2S 53 3600 303x188

3612 3F Dodeca 300 2x32 CT HF 2S 69 4800 303x188

3613 3F Dodeca 300 2x42 CT HF 2S 91 6400 303x188

EP emergency, fuse - Lamps supplied

3615 3F Dodeca 300 1x26 CD HF EP 2S 26 1800 303x188

3616 3F Dodeca 300 1x32 CT HF EP 2S 34 2400 303x188

3617 3F Dodeca 300 1x42 CT HF EP 2S 44 3200 303x188

3620 3F Dodeca 300 2x26 CD HF EP 2S 53 3600 303x188

3621 3F Dodeca 300 2x32 CT HF EP 2S 69 4800 303x188

3622 3F Dodeca 300 2x42 CT HF EP 2S 91 6400 303x188

3F Dodeca 300

L<200 cd/m² 65°

E>75%

Average luminance <200 cd/m² for radial angles >65°.2S dodecagonal optic made of aluminum foil half-mirror, antiglare, mounted on a polycarbonate support.

Page 154: 3F Filippi  "General catalogue 2016"

151Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

3F Dodeca 300 2MG VS

Code 3656

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

3656 3F Dodeca 300 1x42 CT HF 2MG VS 44 3200 303x188

EP emergency, fuse - Lamps supplied

3658 3F Dodeca 300 1x42 CT HF EP 2MG VS 44 3200 303x188

E>77%

2MG dodecagonal optic composed of aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked and in line with the trim.

3F Dodeca 300 2MG SK

Code 36381

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

Ø x H

EEI A2 electronic wiring - Lamps supplied

36381 3F Dodeca 300 2x32 CT HF 2MG SK 69 4800 303x188

36382 3F Dodeca 300 2x42 CT HF 2MG SK 91 6400 303x188

EP emergency, fuse - Lamps supplied

36423 3F Dodeca 300 2x32 CT HF EP 2MG SK 69 4800 303x188

36424 3F Dodeca 300 2x42 CT HF EP 2MG SK 91 6400 303x188

3F Dodeca 300

L<200 cd/m² 60°

E>71%

Average luminance <200 cd/m² for radial angles >65°.2MG SK dodecagonal optic with high shielding and central cross and aluminum foil mirror, high efficiency, with titanium magnesium surface treatment, non-iridescent, mounted on a polycarbonate support.

Page 155: 3F Filippi  "General catalogue 2016"

152

Reinforcing bracket for panels 600x600, 600x1200 with exposed structure, in hot-galvanised steel.

Code Item

A0202 False ceiling bracket - for luminaire D.220

A0203 False ceiling bracket- for luminaire D.300

Closing diffuser for environments where a good protection degree is required, or tamper-proof luminaires are necessary, in transparent self-extinguishing V2 polycarbonate, UV stabilised, prismatic.Quick lock-in mounting, inside the louvre, 3F Dodeca AC excluded.Recessed versions, IP44 exposed part.

Code Item

A0194 Diffuser IP44 (3F Dodeca 220)

Decorative moulded tempered glass, attached with springs on the trim, thickness 4 mm, steel springs for lock-in mounting on the trim.Recessed versions, IP44 exposed part.

Code Item

A0196 Moulded glass (3F Dodeca 220, 220 AC)

A0198 Moulded glass (3F Dodeca 300)

A0196 Only 1-2x18W versions, 1x26, 1x42 for an optimal operating temperature.A0198 Only for versions 1x26, 1x32, 1x42, for optimal operating temperature.Not be installed on SK version and offices with monitors.

Accessories

3F Dodeca

Transparent tempered glass, attached with springs on the trim, thickness 4 mm, steel springs for lock-in mounting on the trim.Recessed versions, IP44 exposed part.

Code Item

A0195 Transparent glass (3F Dodeca 220, 220 AC)

A0197 Transparent glass (3F Dodeca 300)

A0195 Only 1-2x18W versions, 1x26, 1x42 for an optimal operating temperature.A0197 Only for versions 1x26, 1x32, 1x42, for optimal operating temperature.Not be installed on SK version and offices with monitors.

Page 156: 3F Filippi  "General catalogue 2016"

153Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Reinforcing bracket for metal panels 600x600 with concealed structure, in hot-galvanized steel.

Code Item

A0214 Metal pan. reinforcing bracket (3F Dodeca 220)

A0215 Metal pan. reinforcing bracket (3F Dodeca 300)

Accessories

3F Dodeca

Anti-rotation adapter for grilled ceiling with closing mats (always suggested to avoid stray light).Adapter made in steel - white color, RAL 9010.

Code Item

A0204 Grid bracket h40mm - for luminaire D.220

A0205 Grid bracket h40mm - for luminaire D.300

A01523 Grid bracket h50mm - for luminaire D.220

A01524 Grid bracket h50mm - for luminaire D.300

3F Dodeca 220 - 3F Dodeca 220 AC: bracket size 289x289 mm for 50x50, 75x75, 100x100 mesh, slat 10 mm thick.3F Dodeca 300: bracket size 389x389 mm for 50x50, 100x100 mesh, slat 10 mm thick.On request: RAL colour, bracket for grid with h=50 mm; bracket for 75x75 mesh with h=40 mm for 3F Dodeca 300.

Page 157: 3F Filippi  "General catalogue 2016"

154

New

L 320 LEDLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanised steel painted in white polyester.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.EP mantained emergency wiring on one single LED module, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Environments: staterooms, with VDTs, offices.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• diffuser in OP opal PMMA or SP polycarbonate, self-extinguishing V2

• luminaires for pull-up installation with brackets

• different powers or colour temperatures

Accessories

Accessories on page 182.

A

H

12.5

6

12.5

6

L

Page 158: 3F Filippi  "General catalogue 2016"

155Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED 2S

Code 28826

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

28826 L 323x10W LED 2S 596x596 34 3774 596x596x80

DALI electronic

28838 L 323x10W LED DALI 2S 596x596 34 3774 596x596x80

EP emergency, fuse

28829 L 323x10W LED EP 2S 596x596 34 3774 596x596x80

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

L 320 LED 2MG

Code 28844

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

28844 New L 323x10W LED 2MG 596x596 34 4046 596x596x80

DALI electronic

28856 New L 323x10W LED DALI 2MG 596x596 34 4046 596x596x80

EP emergency, fuse

28847 New L 323x10W LED EP 2MG 596x596 34 4046 596x596x80

L 320 LED

L<1000 cd/m² 65°

E=100%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 159: 3F Filippi  "General catalogue 2016"

156

L 320 LED SP

Code 21244

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21244 L 323x10W LED SP 596x596 34 3935 596x596x80

21287 New L 322x18W LED SP 296x1196 40 4954 1196x296x95

21245 L 324x10W LED SP 596x596 45 5207 596x596x80

DALI electronic

21256 L 323x10W LED DALI SP 596x596 34 3935 596x596x80

21290 New L 322x18W LED DALI SP 296x1196 40 4954 1196x296x95

21257 L 324x10W LED DALI SP 596x596 45 5207 596x596x80

EP emergency, fuse

21262 L 323x10W LED EP SP 596x596 34 3935 596x596x80

21293 New L 322x18W LED EP SP 296x1196 40 4954 1196x296x95

21263 L 324x10W LED EP SP 596x596 45 5207 596x596x80

L 320 LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

Page 160: 3F Filippi  "General catalogue 2016"

157Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED LGS

Code 21580

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21580 New L 323x10W LED LGS 596x596 34 2997 596x596x80

21600 New L 322x18W LED LGS 296x1196 40 3851 1196x296x95

21581 New L 324x10W LED LGS 596x596 45 4047 596x596x80

DALI electronic

21586 New L 323x10W LED DALI LGS 596x596 34 2997 596x596x80

21603 New L 322x18W LED DALI LGS 296x1196 40 3851 1196x296x95

21587 New L 324x10W LED DALI LGS 596x596 45 4047 596x596x80

EP emergency, fuse

21589 New L 323x10W LED EP LGS 596x596 34 2997 596x596x80

21606 New L 322x18W LED EP LGS 296x1196 40 3851 1196x296x95

21590 New L 324x10W LED EP LGS 596x596 45 4047 596x596x80

L 320 LED

L<1500 cd/m² 65°

E=100%

2x - 4x - Average luminance <3000 cd/m² for radial angles >65°.3x - Average luminance <1500 cd/m² for radial angles >65°.LGS micro-prismatic flat diffuser in transparent methacrylate, multilenticular exterior, anti-glare, locked to the white painted aluminium perimetral frame, sealing gasket, hinged opening.Anti-glare opal polycarbonate filter for brightness uniformity.

Page 161: 3F Filippi  "General catalogue 2016"

158

New

L 320 LED Diffused lightLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.IP54 protection degree for exposed part, IP20 for recessed part.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Quick connection.In compliance with EN 60598-1.

Dimensions

Applications

Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.LGS versionEnvironments: staterooms, with VDTs, offices.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Squared LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers or colour temperatures• diffuser in SP prismatic PMMA or SP

polycarbonate, Selfextinguishing V2• wiring: emergency• luminaires for pull-up installation with

brackets

Accessories

Accessories on page 182.

A

H

12.5

6

12.5

6

L

Page 162: 3F Filippi  "General catalogue 2016"

159Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED Diffused light LGS

Code 21422

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21422 New L 320 32W LED LGS 596x596 34 2908 596x596x80

DALI electronic

21424 New L 320 32W LED DALI LGS 596x596 34 2908 596x596x80

L<1500 cd/m² 65°

E=100%

Average luminance <1500 cd/m² for radial angles >65°.LGS micro-prismatic flat diffuser in transparent methacrylate, multilenticular exterior, anti-glare, locked to the white painted aluminium perimetral frame, sealing gasket, hinged opening.Anti-glare opal polycarbonate filter for brightness uniformity.

L 320 LED Diffused Light Opal

Code 21408

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21408 L 320 32W LED OP 596x596 34 3328 596x596x80

DALI electronic

21410 L 320 32W LED DALI OP 596x596 34 3328 596x596x80

L 320 LED Diffused light

E=100%

OP opal PMMA flat diffuser, anti-glare, locked to the pre-painted white aluminium perimeter frame with sealing gasket, hinged opening.

Page 163: 3F Filippi  "General catalogue 2016"

160

New

L 320 LED HCLWellbeing LED fixture

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Micro-prismatic flat diffuser in transparent PMMA, multilenticular exterior, anti-glare, locked to the white painted aluminium perimetral frame, sealing gasket, hinged opening.Anti-glare opal polycarbonate filter for brightness uniformity.

Electrical characteristicsDALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Any environments requiring light which aims for the wellness of people.Environments with VDTs.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Light Management

In this product the light intensity and color temperature can be controlled automatically or manually, with the “Controller HCL” (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature from 2700 K to 6500 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• diffuser in SP prismatic PMMA or SP polycarbonate, Selfextinguishing V2

• luminaires for pull-up installation with brackets

Accessories

Accessories on page 182.

A

H

12.5

6

12.5

6

L

Page 164: 3F Filippi  "General catalogue 2016"

161Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED HCL LGS

Code 21613

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

21615 New L 323x10W LED DALI HCL LGS 596x596 35 2919 596x596x80

L 320 LED HCL

L<1500 cd/m² 65°

E=100%

Average luminance <1500 cd/m² for radial angles >65°.LGS micro-prismatic flat diffuser in transparent methacrylate, multilenticular exterior, anti-glare, locked to the white painted aluminium perimetral frame, sealing gasket, hinged opening.Anti-glare opal polycarbonate filter for brightness uniformity.Variable light intensity and color temperature.

Page 165: 3F Filippi  "General catalogue 2016"

162

L 320 LED SensorLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanised steel painted in white polyester.IP54 protection degree for exposed part, IP20 for recessed part.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.On board DALI light sensor (no cables to be added).CF Corridor function: even with the environment free of people, the luminous flux is maintained at 10%.

Dimensions

Applications

Environments: staterooms, with VDTs, offices.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Light Management

For more information on 3F Sensor technology, refer to the specific chapter in the “Light Management” section.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• diffuser in OP opal PMMA or SP polycarbonate, self-extinguishing V2

• different powers or colour temperatures• wiring: EP emergency• luminaires for pull-up installation with

brackets

Accessories

Accessories on page 182.

A

H

12.5

6

12.5

6

L

Page 166: 3F Filippi  "General catalogue 2016"

163Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED Sensor SP

Code 21282

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21282 L 323x10W LED Sensor CF SP 596x596 34 3935 596x59x80

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

L 320 LED Sensor LGS

Code 21598

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21598 New L 323x10W LED Sensor CF LGS 596x596 34 2997 596x596x80

L 320 LED Sensor

L<1500 cd/m² 65°

E=100%

Average luminance <1500 cd/m² for radial angles >65°.LGS micro-prismatic flat diffuser in transparent methacrylate, multilenticular exterior, anti-glare, locked to the white painted aluminium perimetral frame, sealing gasket, hinged opening.Anti-glare opal polycarbonate filter for brightness uniformity.

Page 167: 3F Filippi  "General catalogue 2016"

164

New

L 320 LED Wall WasherRecessed luminaire with Wall Washer light distribution

Construction characteristics

Illuminotechnical characteristicsDirect Wall Washer distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted steel.Black painted heads inside louvre compartment.Wall Washer parabolic flux recuperator in semi-specular aluminium.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments where uniform vertical illumination of walls, panels, blackboards, shelves and display units is required.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers or colour temperatures• wiring: dimmable, emergency

50

A

12.5

L

H

6 6

Page 168: 3F Filippi  "General catalogue 2016"

165Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 LED WW

Code 21393

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21393 New L 322x24W LED WW 296x1196 56 5418 1196x296x110

L 320 LED Wall Washer

E>100%

Wall Washer parabolic flux recuperator in semi-specular aluminium.

Page 169: 3F Filippi  "General catalogue 2016"

166

L 320 FluoLuminaire suitable for lay-installation on false ceilings

Construction characteristics

Mechanical characteristicsHousing in hot-galvanized steel and painted in white polyester, for square version.Housing in white painted steel for rectangular or SP IP54 versions.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Versions with twin-circuit (DA) available.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Accessories

Accessories on page 182.

Applications

2M, 2MG, 2US, 2S versionsEnvironments: educational, staterooms, with VDTs, schools, offices.3AO versionEnvironments: architectural, commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.SPA, SP, VS versionsEnvironments requiring a high level of protection, lamp shielding and simplified cleaning.

Source characteristics

• In LD versions, T5 and T8 lamps pre-mounted.

• Fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• MultiWatt electronic ballasts for T5 twin-lamp wirings

• SPO opal PMMA diffuser or SP self-extinguishing V2 polycarbonate diffuser

• luminaires with VSS laminated glass, IP65 exposed part

• SP luminaires with interior prismatic diffuser

• luminaires for pull-up installation with brackets

• fuse accessory (on page 472)• wiring: dimmable, twin-circuit,

emergency, emergency inhibition

A = L

H

12.5

6

12.5

3-4 x T5

12.5

T8

A25

6 H

1x

A12.5

6 H

12.56 H

12.56 H

L L

2-3-4x T5 T8

6 6

Page 170: 3F Filippi  "General catalogue 2016"

167Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 2M

Code 2860

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2860 L 324x14 T5 LD HF 2M 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2861 L 323x14 T5 LD HF 2M 48 3600 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2864 L 324x14 T5 LD HF DA 2M 62 4800 596x596x80

EP emergency, fuse - Pre-mounted lamps

2863 L 323x14 T5 LD HF EP 2M 48 3600 596x596x80

2862 L 324x14 T5 LD HF EP 2M 62 4800 596x596x80

2865 L 324x14 T5 LD HF DA EP 2M 62 4800 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>74%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 171: 3F Filippi  "General catalogue 2016"

168

L 320 T8 2M

Code 2870

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2870 L 324x18 LD HF 2M 74 5400 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2002 L 323x18 LD HF 2M 55 4050 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2003 L 324x18 LD HF DA 2M 74 5400 596x596x80

EP emergency, fuse - Pre-mounted lamps

2871 L 324x18 LD HF EP 2M 74 5400 596x596x80

EEI A2 electronic wiring - Lamps not included

21114 L 321x18 HF 2M 19 1350 596x196x95

21115 L 322x18 HF 2M 35 2700 596x296x95

21116 L 321x36 HF 2M 36 3350 1196x196x95

21117 L 322x36 HF 2M 71 6700 1196x296x95

21118 L 323x36 HF 2M 107 10050 1196x596x95

21119 L 324x36 HF 2M 142 13400 1196x596x95

L 320 Fluo

L<200 cd/m² 65°

E>66%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 172: 3F Filippi  "General catalogue 2016"

169Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 2MG

Code 2914

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2914 L 324x14 T5 LD HF 2MG 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2915 L 323x14 T5 LD HF 2MG 48 3600 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2918 L 324x14 T5 LD HF DA 2MG 62 4800 596x596x80

Twin-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2190 L 322x28 T5 LD HF 2MG 60 5200 1196x296x95

With two ballasts - EEI A2 electronic wiring - Pre-mounted lamps

2191 L 323x28 T5 LD HF 2MG 91 7800 1196x596x95

EP emergency, fuse - Pre-mounted lamps

2917 L 323x14 T5 LD HF EP 2MG 48 3600 596x596x80

2916 L 324x14 T5 LD HF EP 2MG 62 4800 596x596x80

2919 L 324x14 T5 LD HF DA EP 2MG 62 4800 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>84%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 173: 3F Filippi  "General catalogue 2016"

170

L 320 T8 2MG

Code 2792

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

21124 L 322x36 HF 2MG 71 6700 1196x296x95

21125 L 323x36 HF 2MG 107 10050 1196x596x95

21126 L 324x36 HF 2MG 142 13400 1196x596x95

Four-lamp ballast - EEI A2 electronic wiring - Lamps not included

2792 L 324x18 HF 2MG 74 5400 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Lamps not included

2012 L 323x18 HF 2MG 55 4050 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Lamps not included

2013 L 324x18 HF DA 2MG 74 5400 596x596x80

EP emergency, fuse - Lamps not included

2793 L 324x18 HF EP 2MG 74 5400 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>75%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 174: 3F Filippi  "General catalogue 2016"

171Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 2US

Code 2872

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2872 L 324x14 T5 LD HF 2US 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2873 L 323x14 T5 LD HF 2US 48 3600 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2876 L 324x14 T5 LD HF DA 2US 62 4800 596x596x80

EP emergency, fuse - Pre-mounted lamps

2875 L 323x14 T5 LD HF EP 2US 48 3600 596x596x80

2874 L 324x14 T5 LD HF EP 2US 62 4800 596x596x80

2877 L 324x14 T5 LD HF DA EP 2US 62 4800 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>72%

Average luminance <200 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 175: 3F Filippi  "General catalogue 2016"

172

L 320 T8 2US

Code 2882

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2882 L 324x18 LD HF 2US 74 5400 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2022 L 323x18 LD HF 2US 55 4050 596x596x80

Twin-circuit, twin-lamp ballast, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2023 L 324x18 LD HF DA 2US 74 5400 596x596x80

EEI A2 electronic wiring - Lamps not included

21133 L 321x18 HF 2US 19 1350 596x196x95

21134 L 322x18 HF 2US 35 2700 596x296x95

21135 L 321x36 HF 2US 36 3350 1196x196x95

21136 L 322x36 HF 2US 71 6700 1196x296x95

EP emergency, fuse - Pre-mounted lamps

2883 L 324x18 LD HF EP 2US 74 5400 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>63%

Average luminance <200 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 176: 3F Filippi  "General catalogue 2016"

173Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 2S

Code 2930

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2930 L 324x14 T5 LD HF 2S 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2931 L 323x14 T5 LD HF 2S 48 3600 596x596x80

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2934 L 324x14 T5 LD HF DA 2S 62 4800 596x596x80

Twin-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2192 L 322x28 T5 LD HF 2S 60 5200 1196x296x95

With two ballasts - EEI A2 electronic wiring - Pre-mounted lamps

2193 L 323x28 T5 LD HF 2S 91 7800 1196x596x95

EP emergency, fuse - Pre-mounted lamps

2933 L 323x14 T5 LD HF EP 2S 48 3600 596x596x80

2932 L 324x14 T5 LD HF EP 2S 62 4800 596x596x80

2935 L 324x14 T5 LD HF DA EP 2S 62 4800 596x596x80

L 320 Fluo

L<200 cd/m² 65°

E>75%

Average luminance <200 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 177: 3F Filippi  "General catalogue 2016"

174

L 320 T8 2S

Code 2760

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Lamps not included

2760 L 324x18 HF 2S 74 5400 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Lamps not included

2032 L 323x18 HF 2S 55 4050 596x596x80

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Lamps not included

2033 L 324x18 HF DA 2S 74 5400 596x596x80

EP emergency, fuse - Lamps not included

2761 L 324x18 HF EP 2S 74 5400 596x596x80

EEI A2 electronic wiring - Lamps not included

21142 L 321x18 HF 2S 19 1350 596x196x95

21143 L 322x18 HF 2S 35 2700 596x296x95

21144 L 321x36 HF 2S 36 3350 1196x196x95

21145 L 322x36 HF 2S 71 6700 1196x296x95

21146 L 323x36 HF 2S 107 10050 1196x596x95

21147 L 324x36 HF 2S 142 13400 1196x596x95

L 320 Fluo

L<200 cd/m² 65°

E>67%

Average luminance <200 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 178: 3F Filippi  "General catalogue 2016"

175Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 3AO

Code 2884

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2884 L 324x14 T5 LD HF 3AO 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2885 L 323x14 T5 LD HF 3AO 48 3600 596x596x80

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2888 L 324x14 T5 LD HF DA 3AO 62 4800 596x596x80

EP emergency, fuse - Pre-mounted lamps

2887 L 323x14 T5 LD HF EP 3AO 48 3600 596x596x80

2886 L 324x14 T5 LD HF EP 3AO 62 4800 596x596x80

2889 L 324x14 T5 LD HF DA EP 3AO 62 4800 596x596x80

L 320 Fluo

L<3000 cd/m² 65°

E>67%

Average luminance <3000 cd/m² for radial angles >65°.3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 179: 3F Filippi  "General catalogue 2016"

176

L 320 T8 3AO

Code 2894

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2894 L 324x18 LD HF 3AO 74 5400 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2052 L 323x18 LD HF 3AO 55 4050 596x596x80

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

2053 L 324x18 LD HF DA 3AO 74 5400 596x596x80

EP emergency, fuse - Pre-mounted lamps

2895 L 324x18 LD HF EP 3AO 74 5400 596x596x80

EEI A2 electronic wiring - Lamps not included

21153 L 321x18 HF 3AO 19 1350 597x196x95

21154 L 322x18 HF 3AO 35 2700 597x296x95

21155 L 322x36 HF 3AO 71 6700 1196x297x95

21156 L 324x36 HF 3AO 142 13400 1196x596x95

L 320 Fluo

L<3000 cd/m² 65

E>61%

Average luminance <3000 cd/m² for radial angles >65°.3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 180: 3F Filippi  "General catalogue 2016"

177Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T8 SPA

Code 21171

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

21172 L 323x18 HF SPA 55 4050 596x596x84

21171 L 324x18 HF SPA 74 5400 596x596x84

EP emergency, fuse - Lamps not included

21176 L 323x18 HF EP SPA 55 4050 596x596x84

21175 L 324x18 HF EP SPA 74 5400 596x596x84

E>58%

SPA screen top in transparent methacrylate, externally prismatic, anti-glare, lay-in installation on the structure, without frame.

L 320 T5 SPA

Code 2978

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2978 L 324x14 T5 LD HF SPA 62 4800 596x596x84

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2979 L 323x14 T5 LD HF SPA 48 3600 596x596x84

EP emergency, fuse - Pre-mounted lamps

2981 L 323x14 T5 LD HF EP SPA 48 3600 596x596x84

2980 L 324x14 T5 LD HF EP SPA 62 4800 596x596x84

L 320 Fluo

E>70%

SPA screen top in transparent methacrylate, externally prismatic, anti-glare, lay-in installation on the structure, without frame.

Page 181: 3F Filippi  "General catalogue 2016"

178

L 320 T8 SP

Code 2857

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

21188 L 321x18 HF SP 19 1350 596x196x95

21189 L 322x18 HF SP 35 2700 596x296x95

21190 L 321x36 HF SP 36 3350 1196x196x95

21182 L 323x18 HF SP 55 4050 596x596x80

2857 L 324x18 HF SP 74 5400 596x596x80

21191 L 322x36 HF SP 71 6700 1196x296x95

21192 L 323x36 HF SP 107 10050 1196x596x95

21193 L 324x36 HF SP 142 13400 1196x596x95

E>53%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

L 320 T5 SP

Code 2847

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2847 L 324x14 T5 LD HF SP 62 4800 596x596x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2848 L 323x14 T5 LD HF SP 48 3600 596x596x80

EP emergency, fuse - Pre-mounted lamps

2850 L 323x14 T5 LD HF EP SP 48 3600 596x596x80

2849 L 324x14 T5 LD HF EP SP 62 4800 596x596x80

L 320 Fluo

E>65%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

Page 182: 3F Filippi  "General catalogue 2016"

179Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 T5 SP IP54

Code 2175

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2175 L 324x14 T5 LD HF SP IP54 62 4800 596x596x95

EP emergency, fuse - Pre-mounted lamps

2177 L 324x14 T5 LD HF EP SP IP54 62 4800 596x596x95

E>65%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.Mounted hanging from rough ceiling or lay-installation.

L 320 T5 VS

Code 2804

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

2804 L 324x14 T5 LD HF VS 62 4800 596x596x80

EP emergency, fuse - Pre-mounted lamps

2805 L 324x14 T5 LD HF EP VS 62 4800 596x596x80

L 320 Fluo

E>60%

VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.

Page 183: 3F Filippi  "General catalogue 2016"

180

L 320 Fluo Decorative BorderEye-catching recessed luminaire with aluminium edge

Construction characteristics

Illuminotechnical characteristicsAverage luminance <200 cd/m² for radial angles >65°.

Mechanical characteristicsHousing in hot-galvanised steel painted in white polyester.Decorative edge in semi-glossy aluminium.Parabolic louvre in specular aluminium with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Versions with twin-circuit (DA) available.

Dimensions

Applications

Environments: publics, staterooms, with VDTs, schools, offices.

Installation

Metal panels 600x600, use fixing brackets item 15 LB.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• luminaires with LED sources• parabolic louvres 2MG, 2US, 2S, 3DEC, 3AO• version with SP flat diffuser• white or coloured decorative edge• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 182.

A = L

H6

14

H

14

6

Page 184: 3F Filippi  "General catalogue 2016"

181Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 320 Decorative Border

Code 21002

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

21002 L 324x14 T5 LD HF BA 2M 62 4800 599x599x80

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

21003 L 323x14 T5 LD HF BA 2M 48 3600 599x599x80

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

21010 L 324x14 T5 LD HF DA BA 2M 62 4800 599x599x80

L 320 Fluo Decorative Border

L<200 cd/m² 65°

E=74%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 185: 3F Filippi  "General catalogue 2016"

182

Anti-fall safety cable for fixing the housing to the building structure.

Code Item

A0477 Safety wire

This accessory is suitable only for square products (except models: L 320 LED Diffused light and IP54 versions).

Fixing bracket for installation coplanar with metal panels with concealed structure.Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0179 15LB

Fixing in two positions (excursion min. 23 mm, max. 36 mm) or (excursion min. 53 mm, max. 66 mm).Only for L 320 Decorative Border.

Fixing bracket for ceiling pull-up installation.Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0170 15BS

For rectangular luminaires (excursion min. 18 mm, max. 45 mm).

Accessories

L 320

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0177 15ZH

For squared luminaires with optic (excursion min. 0 mm, max. 60 mm), with screen or glass (excursion min. 15 mm, max. 60 mm).For rectangular luminaires (excursion min. 45 mm, max. 72 mm).

Page 186: 3F Filippi  "General catalogue 2016"

183Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Accessories

L 320

For luminaires 80 mm high.Plug for quick connection of the luminaire, 3-pole irreversible to be snapped (Snap-in), with integrated locking device, H07 V2-U HT90° 1.5 mm² cables, for the connection to the terminal block of the luminaire.Connection for single-circuit wiring: order white plug.Connection for twin-circuit, dimmable, emergency wiring: order white plug plus black plug.

Code Item

A0720 Wieland (white plug)

A0721 Wieland (white plug)

A0722 Ensto (white plug+ adapter)

A0725 Wieland (black plug)

A0726 Wieland (black plug)

A0727 Ensto (black plug+ adapter)

Page 187: 3F Filippi  "General catalogue 2016"

184

L 350 LEDRecessed LED luminaire with high luminous flux

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Film protective against dust and finger marks, adhesive, attached to louvre.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Quick connection.

Dimensions

Applications

Ambient temperatures up to +25°C (3AO version).Environments: architectural, commercial, exhibition areas.Environments where high levels of light are required.Warning: 3AO luminaire not suitable for installation in false ceilings without heat removal capacity.Minimum void of 200 mm required.

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 7 compliant.

On request

• sources in different powers or colour temperatures

• luminaires for pull-up installation with brackets

• wiring: dimmable

Accessories

Accessories on page 189.

A = L12.5

H6

H6

12.5

Page 188: 3F Filippi  "General catalogue 2016"

185Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 350 LED SP

Code 260092

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

260092 L 353x14W LED SP 54V 596x596 47 5483 596x596x80

DALI electronic

260094 New L 353x14W LED DALI SP 54V 596x596 47 5483 596x596x80

E=100%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

L 350 LED 3AO

Code 260078

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

260078 New L 353x25W LED 3AO 596x596 82 7837 596x596x80

DALI electronic

260080 New L 353x25W LED DALI 3AO 596x596 82 7837 596x596x80

L 350 LED

L<3000 cd/m² 65

E=100%

Average luminance <3000 cd/m² for radial angles >65°.3AO Decorative parabolic louvre in matt silver aluminium, antiglare, with transverse blades closed at the top and prismatic PMMA diffusers for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 189: 3F Filippi  "General catalogue 2016"

186

L 350 FluoRecessed fluorescent luminaire with high luminous flux

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.COM parabolic louvre, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.Flow recuperator in specular aluminium, with superficial titanium-magnesium treatment, non-iridescent.RSP flux recuperator and flat diffuser in transparent PMMA, prismatic exterior, anti-glare, white painted aluminium frame, sealing gasket, hinged opening, IP54 exposed part.RVS flux recuperator and moulded glass, tempered, with white painted aluminium frame, sealing gasket, hinged opening, IP54 exposed part.RVSS flux recuperator and laminated moulded glass, with white painted steel frame, sealing gasket, hinged opening, IP65 exposed part.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EP maintained emergency wiring on one single lamp, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

COM versionEnvironments: architectural, commercial, exhibition areas.Environments where high levels of light are required.Important: suitable only for false ceilings with capability of heat dissipation e.g. with min. void of 200 mm and ventilation, no closed upper compartments.RSP, RVS versionsEnvironments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.RVSS versionEnvironments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.

Source characteristics

• Compact fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• low luminance louvres• luminaires for pull-up installation with

brackets• fuse accessory (on page 472)• wiring: dimmable, twin-circuit• emergency inhibition

Accessories

Accessories on page 189.

A = L12.5

H6

H6

12.5

Page 190: 3F Filippi  "General catalogue 2016"

187Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 350 RSP

Code 2827

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2827 L 352x55 C LD HF RSP 54V 118 8600 596x596x80

EP emergency, fuse - Pre-mounted lamps

2828 L 352x55 C LD HF EP RSP 54V 118 8600 596x596x80

E>74%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.SP PMMA flat diffuser, prismatic outer surface, anti-glare, locked to the white painted aluminium perimetrical frame with sealing gasket, hinged opening.

L 350 COM

Code 2825

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2825 L 353x55 C LD HF COM 178 12900 596x596x80

Wiring on a separate unit - EP emergency, fuse - Pre-mounted lamps

2826 L 353x55 C LD HF EP COM 178 12900 596x596x80

L 350 Fluo

E>77%

COM parabolic louvre, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with white painted transverse blades.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 191: 3F Filippi  "General catalogue 2016"

188

L 350 RVSS

Code 2837

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2837 L 352x55 C LD HF RVSS 118 8600 596x596x84

EP emergency, fuse - Pre-mounted lamps

2838 L 352x55 C LD HF EP RVSS 118 8600 596x596x84

E>68%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VSS printed laminated dipped glass, non-combustible, stuck to the perimeter frame in white painted stainless steel, with sealing gasket, hinged opening.

L 350 RVS

Code 2831

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2831 L 352x55 C LD HF RVS 54V 118 8600 596x596x80

EP emergency, fuse - Pre-mounted lamps

2832 L 352x55 C LD HF EP RVS 54V 118 8600 596x596x80

L 350 Fluo

E>76%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.

Page 192: 3F Filippi  "General catalogue 2016"

189Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

For luminaires 80 mm high.Plug for quick connection of the luminaire, 3-pole irreversible to be snapped (Snap-in), with integrated locking device, H07 V2-U HT90° 1.5 mm² cables, for the connection to the terminal block of the luminaire.Connection for single-circuit wiring: order white plug.Connection for twin-circuit, dimmable, emergency wiring: order white plug plus black plug.

Code Item

A0720 Wieland (white plug)

A0721 Wieland (white plug)

A0722 Ensto (white plug+ adapter)

A0725 Wieland (black plug)

A0726 Wieland (black plug)

A0727 Ensto (black plug+ adapter)

Anti-fall safety cable for fixing the housing to the building structure.

Code Item

A0477 Safety wire

This accessory is suitable only for square products (except models: L 350 Fluo R90 and IP54 versions).

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0177 15ZH

3AO - COM - RVSS (excursion min. 0 mm, max. 60 mm).SP - RSP - RVS (excursion min. 15 mm, max. 60 mm).

Accessories

L 350

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0173 15HI

SP - RSP - RVS (excursion min. 0 mm, max. 25 mm).

Page 193: 3F Filippi  "General catalogue 2016"

190

L 350 Fluo R90Recessed fluorescent luminaire with high luminous flux

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution, wide or concentrated.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Total flux recuperator for wide or concentrated distribution, in specular aluminium with titanium-magnesium surface treatment, non-iridescent.Device to prevent lamp from falling.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit.

Dimensions

Applications

Environments: architectural, commercial, exhibition areas.Environments where high levels of light are required.Important: suitable only for false ceilings with capability of heat dissipation e.g. with min. void of 200 mm and ventilation, no closed upper compartments.

Installation

Installation following false ceiling mounting, supported by the exposed structure, minimum void of 210 mm from the structure’s lower edge.

Source characteristics

• Compact fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• fuse accessory (on page 472)• wiring: dimmable• emergency inhibition

A = L

H

13

6

H6

13

Page 194: 3F Filippi  "General catalogue 2016"

191Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 350 R90

Code 4953

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Twin-circuit, version with WIDE flow recuperator - EEI A2 electronic wiring - Pre-mounted lamps

4952 L 350 R90 4x40 C LD HF DA 178 14000 596x596x88

4953 L 350 R90 4x55 C LD HF DA 236 17200 596x596x88

Twin-circuit, version with CONCENTRATED flow recuperator - EEI A2 electronic wiring - Pre-mounted lamps

4972 L 350 R90 4x55 C LD HF DA CONC 236 17200 596x596x88

L 350 Fluo R90

E>90%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.

Page 195: 3F Filippi  "General catalogue 2016"

192

New

L 390 LEDWellbeing LED fixture

Construction characteristics

Illuminotechnical characteristicsAverage luminance <3000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in white painted steel.Decorative edge in semi-glossy aluminium.Central 2MG parabolic louvre in specular aluminium with titanium-magnesium surface treatment, non-iridescent, with transverse blades, hinged opening.Opal polycarbonate diffuser for total shielding of the louvre compartment.Flat diffusers lateral to louvre, in anti-glare opal PMMA.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1. Dimensions

Applications

Environments: staterooms, with VDTs, offices.Environments with exacting visual tasks, where diffused soft light for optimum visual comfort is required.These luminaires are suitable for installation both on false ceilings with metal panels with concealed structure, 600x600 mm (using brackets), and lay-installation on 600x600 mm ceiling panels with exposed structure (Armstrong type).

Light Management

The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• satin louvre• different powers or colour temperatures• fluorescent version

Accessories

Accessories on page 196.

22

7H

A L

Page 196: 3F Filippi  "General catalogue 2016"

193Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 390 LED Opal 2MG

Code 21489

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Coplanar or pull-up installation - Electronic

21489 L 390 32W LED 2MG OP 597x597 34 3480 597x597x100

21497 New L 390 2x18W LED 2MG OP 323x1221 40 3634 1221x323x100

Coplanar or pull-up installation - DALI electronic

21491 L 390 32W LED DALI 2MG OP 597x597 34 3480 597x597x100

21499 New L 390 2x18W LED DALI 2MG OP 323x1221 40 3634 1221x323x100

L 390 LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Opal polycarbonate diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.Flat diffusers lateral to louvre, in anti-glare opal PMMA.Coplanar or pull-up installation.

Page 197: 3F Filippi  "General catalogue 2016"

194

L 390 LED HCLWellbeing LED fixture

Construction characteristics

Illuminotechnical characteristicsLifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in white painted steel.Decorative edge in semi-glossy aluminium.Central 2MG parabolic louvre in specular aluminium with titanium-magnesium surface treatment, non-iridescent, with transverse blades, hinged opening.Opal polycarbonate diffuser for total shielding of the louvre compartment.Flat diffusers lateral to louvre, in anti-glare opal PMMA.

Electrical characteristicsDALI electronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Any environments requiring light which aims for the wellness of people.Environments with VDTs.Environments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.These luminaires are suitable for installation both on false ceilings with metal panels with concealed structure, 600x600 mm (using brackets), and lay-installation on 600x600 mm ceiling panels with exposed structure (Armstrong type).

Light Management

In this product the light intensity and color temperature can be controlled automatically or manually, with the “Controller HCL” (see “Light Management” chapter).

Source characteristics

• Squared LED modules, CCT nominal color temperature from 2700 K to 6500 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Accessories

Accessories on page 196.

22

A = L

7

H

Page 198: 3F Filippi  "General catalogue 2016"

195Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 390 LED HCL

Code 21506

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Coplanar or pull-up installation - DALI electronic

21506 L 390 33W LED DALI HCL 2MG OP 597x597 39 3325 597x597x100

L 390 LED HCL

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Opal polycarbonate diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.Flat diffusers lateral to louvre, in anti-glare opal PMMA.Coplanar or pull-up installation.

Page 199: 3F Filippi  "General catalogue 2016"

196

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0173 15HI

Coplanar installation on metal panels with concealed structure (excursion min. 17 mm, max. 52 mm).

Accessories

L 390

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0177 15ZH

Pull-up installation on mineral-fibre panels or plasterboard. (excursion min. 34 mm, max. 69 mm).

Page 200: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 201: 3F Filippi  "General catalogue 2016"

198

L 400 FluoLuminaire suitable for pull-up installation on false ceiling

Construction characteristics

Mechanical characteristicsHousing in white painted steel.Parabolic louvres with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.PMMA flat diffuser transparent, prismatic, anti-glare, SP with exterior prismatic diffuser, prismatic interior on request, white painted aluminium frame, hinge opening, IP43 exposed part.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Versions with twin-circuit (DA) available.

Dimensions

Accessories

Accessories on page 203.

Applications

2M, 2MG, 2US, 2S versionsEnvironments: publics, staterooms, with VDTs, schools, offices.3AO versionEnvironments: architectural, commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.SP versionEnvironments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• MultiWatt electronic ballasts for T5 twin-lamp wirings

• SPO opal PMMA diffuser, in SP self-extinguishing V2 polycarbonate, 6.5J - 850°C or glass

• fixing brackets• recessed luminaire for metal panels

500x500• fuse accessory (on page 472)• wiring: dimmable, twin-circuit,

emergency• LED version

H

H

25

A = L

6H3-4 x

25

6T5

T86

25

Page 202: 3F Filippi  "General catalogue 2016"

199Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 400 T5 2MG

Code 27560

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

27560 L 404x14 T5 HF 2MG 62 4800 621x621x95

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

27561 L 403x14 T5 HF 2MG 48 3600 621x621x95

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

27562 L 404x14 T5 HF DA 2MG 62 4800 621x621x95

With two ballasts, lamps 2 and 1-3 - EEI A2 electronic wiring - Pre-mounted lamps

27563 L 403x14 T5 HF DA 2MG 48 3600 621x621x95

L<200 cd/m² 65°

E>80%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 400 T8 2M

Code 2245

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2244 L 403x18 HF 2M 55 4050 621x621x95

2245 L 404x18 HF 2M 74 5400 621x621x95

L 400 Fluo

L<200 cd/m² 65°

E>65%

Average luminance <200 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 203: 3F Filippi  "General catalogue 2016"

200

L 400 T8 2US

Code 2227

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2226 L 403x18 HF 2US 55 4050 621x621x95

2227 L 404x18 HF 2US 74 5400 621x621x95

L<200 cd/m² 65°

E>62%

Average luminance <200 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 400 T8 2MG

Code 2248

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2247 L 403x18 HF 2MG 55 4050 621x621x95

2248 L 404x18 HF 2MG 74 5400 621x621x95

L 400 Fluo

L<200 cd/m² 65°

E>70%

Average luminance <200 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 204: 3F Filippi  "General catalogue 2016"

201Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 400 T8 2S

Code 2242

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2241 L 403x18 HF 2S 55 4050 621x621x95

2242 L 404x18 HF 2S 74 5400 621x621x95

L<200 cd/m² 65°

E>65%

Average luminance <200 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 400 T5 2S

Code 27590

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Four-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

27590 L 404x14 T5 HF 2S 62 4800 621x621x95

Three-lamp ballast - EEI A2 electronic wiring - Pre-mounted lamps

27591 L 403x14 T5 HF 2S 48 3600 621x621x95

Twin-circuit, twin-lamp ballasts, lamps 1-4 and 2-3. - EEI A2 electronic wiring - Pre-mounted lamps

27592 L 404x14 T5 HF DA 2S 62 4800 621x621x95

With two ballasts, lamps 2 and 1-3 - EEI A2 electronic wiring - Pre-mounted lamps

27593 L 403x14 T5 HF DA 2S 48 3600 621x621x95

L 400 Fluo

L<200 cd/m² 65°

E>70%

Average luminance <200 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 205: 3F Filippi  "General catalogue 2016"

202

L 400 T8 SP

Code 2225

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2224 L 403x18 HF SP 55 4050 621x621x95

2225 L 404x18 HF SP 74 5400 621x621x95

E>53%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

L 400 T8 3AO

Code 2223

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

2222 L 403x18 HF 3AO 55 4050 621x621x95

2223 L 404x18 HF 3AO 74 5400 621x621x95

L 400 Fluo

E>60%

3AO louvre with square cell section, in matt silver aluminium, anti-glare.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 206: 3F Filippi  "General catalogue 2016"

203Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0177 15ZH

Brackets for lay-installation on load bearing side profiles parallel to the luminaire (excursion min. 45 mm, max. 72 mm).

Accessories

L 400

Fixing bracket for ceiling pull-up installation.Pack for 1 luminaire.

Code Item

A0170 15BS

Brackets for lay-installation on load bearing side profiles parallel to the luminaire (excursion min. 18 mm, max. 45 mm).

Page 207: 3F Filippi  "General catalogue 2016"

204

L 450 FluoLuminaire to create continuous lighting channels

Construction characteristics

Illuminotechnical characteristicsSymmetric and Wall Washer asymmetric lighting distribution.

Mechanical characteristicsHousing in white painted steel.Parabolic louvres with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.Wall Washer parabolic flux recuperator.Perfect joining of louvres/recuperators for continuous lighting channel.Screws with nuts for channel union.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

Dimensions

Applications

2MG versionEnvironments: publics, staterooms, with VDTs, schools, offices.WW versionEnvironments where uniform vertical illumination of walls, panels, blackboards, shelves and display units is required.

Installation

For channel start and end, always order pair of end caps, see accessories.The luminaires are designed to be hung from the rough ceiling; if the ceiling is load bearing use the accessory fixing brackets item 15 HI.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• single points of light• SP flat diffuser• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 206.

A

H

L15.5

Page 208: 3F Filippi  "General catalogue 2016"

205Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 450 Fluo WW

Code 22600

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

22596 L 451x14 T5 LD HF WW 16 1200 571x140x85

22598 L 451x28 T5 LD HF WW 31 2600 1171x140x85

22599 L 451x35 T5 LD HF WW 38 3300 1471x140x85

22600 L 451x49 T5 LD HF WW 53 4300 1471x140x85

22601 L 451x54 T5 LD HF WW 58 4450 1171x140x85

E>65%

Wall Washer parabolic flux recuperator in semi-specular aluminium.

L 450 Fluo 2MG

Code 22404

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

22400 L 451x14 T5 LD HF 2MG 16 1200 571x140x85

22402 L 451x28 T5 LD HF 2MG 31 2600 1171x140x85

22403 L 451x35 T5 LD HF 2MG 38 3300 1471x140x85

22404 L 451x49 T5 LD HF 2MG 53 4300 1471x140x85

22405 L 451x54 T5 LD HF 2MG 58 4450 1171x140x85

L 450 Fluo

L<1000 cd/m² 65°

E>73%

Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 209: 3F Filippi  "General catalogue 2016"

206

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Pack for 1 luminaire.

Code Item

A0173 15HI

Brackets for lay-installation on load bearing side profiles parallel to the luminaire (excursion min. 20 mm, max. 45 mm).

Accessories

L 450

Pair of terminals for luminaire closing and coupling to false ceiling, with screws and nuts for fixing to housing, always necessary.

Code Item

A0164 Pair of closing end caps L 450 T5

Page 210: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 211: 3F Filippi  "General catalogue 2016"

208

L 560 LEDLED luminaire with high energy efficiency for installation on slats or batting

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted steel.2S parabolic louvre in semispecular aluminium with transverse blades closed at the top and prismatic PMMA diffusers for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.SP transparent PMMA diffuser, prismatic, anti-glare, locked to the pre-painted white aluminium perimeter frame with sealing gasket, hinged opening.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1. Dimensions

Applications

2S versionEnvironments: with VDTs, schools, offices.SP versionEnvironments where demanding visual tasks are performed and soft diffuse light is required for optimal visual comfort and total shielding of the light source.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• parabolic louvres 2M, 2MG, 2US, 3AO• different powers or colour temperatures• diffuser in SMP microprismatic PMMA or

SP polycarbonate, Selfextinguishing V2• wiring: dimmable, emergency

Accessories

Accessories on page 215.

A25

6H

H6

L25

Page 212: 3F Filippi  "General catalogue 2016"

209Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 560 LED SP

Code 270961

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

270957 L 561x12W LED SP 221x647 14.5 1435 647x221x95

270963 L 562x12W LED SP 221x647 29.5 2806 647x221x95

270959 L 561x24W LED SP 221x1256 28 2869 1256x221x95

270961 L 561x30W LED SP 221x1556 34 3588 1556x221x95

270965 L 562x24W LED SP 221x1256 56 5612 1256x221x95

270967 L 562x30W LED SP 221x1556 68 7015 1556x221x95

E=100%

SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.

L 560 LED 2S

Code 270935

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

270931 L 561x12W LED 2S 221x647 14.5 1394 647x221x95

270937 L 562x12W LED 2S 221x647 29.5 2664 647x221x95

270933 L 561x24W LED 2S 221x1256 28 2786 1256x221x95

270935 L 561x30W LED 2S 221x1556 34 3482 1556x221x95

270939 L 562x24W LED 2S 221x1256 56 5327 1256x221x95

270941 L 562x30W LED 2S 221x1556 68 6659 1556x221x95

L 560 LED

L<1000 cd/m² 65°

E=100%

1x - Average luminance <1000 cd/m² for radial angles >65°.2x - Average luminance <1500 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 213: 3F Filippi  "General catalogue 2016"

210

L 560 FluoLuminaire for false ceiling with staves (100 or 200 millimetre spacing) or plasterboard

Construction characteristics

Mechanical characteristicsHousing in white painted steel.Parabolic louvres with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.L 562 version without longitudinal central V-shaped element.Flat diffuser in transparent PMMA, prismatic, anti-glare, locked to the white aluminium perimeter frame, hinged opening.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

Dimensions

Applications

2M, 2MG, 2US, 2S versionsEnvironments: publics, staterooms, with VDTs, transit areas, schools, offices.SP versionEnvironments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• parabolic louvre 3AO• SPO opal PMMA diffuser or SP self-

extinguishing V2 6.5J - IK08 - 850°C• fixing brackets• fuse accessory (on page 472)• wiring: dimmable, twin-circuit,

emergency• L 550 luminaires for staves spaced 100,

150, 300 mm

Accessories

Accessories on page 215.

A25

6H

H6

L25

Page 214: 3F Filippi  "General catalogue 2016"

211Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 560 T5 2MG

Code 27525

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

27523 L 561x14 T5 LD HF 2MG 16 1200 647x221x95

27528 L 562x14 T5 LD HF 2MG 31 2400 647x221x95

27524 L 561x28 T5 LD HF 2MG 31 2600 1256x221x95

27526 L 561x35 T5 LD HF 2MG 38 3300 1556x221x95

27527 L 561x49 T5 LD HF 2MG 53 4300 1556x221x95

27525 L 561x54 T5 LD HF 2MG 58 4450 1256x221x95

27529 L 562x28 T5 LD HF 2MG 60 5200 1256x221x95

27531 L 562x35 T5 LD HF 2MG 76 6600 1556x221x95

27532 L 562x49 T5 LD HF 2MG 106 8600 1556x221x95

27530 L 562x54 T5 LD HF 2MG 114 8900 1256x221x95

L<200 cd/m² 65°

E>71%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 560 T8 2M

Code 22283

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

22281 L 561x18 HF 2M 19 1350 647x221x95

22284 L 562x18 HF 2M 35 2700 647x221x95

22282 L 561x36 HF 2M 36 3350 1256x221x95

22283 L 561x58 HF 2M 55 5200 1556x221x95

22285 L 562x36 HF 2M 71 6700 1256x221x95

22286 L 562x58 HF 2M 109 10400 1556x221x95

L 560 Fluo

L<200 cd/m² 65°

E>65%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2M parabolic louvre in specular aluminium, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 215: 3F Filippi  "General catalogue 2016"

212

L 560 T8 2US

Code 22313

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

22311 L 561x18 HF 2US 19 1350 647x221x95

22314 L 562x18 HF 2US 35 2700 647x221x95

22312 L 561x36 HF 2US 36 3350 1256x221x95

22313 L 561x58 HF 2US 55 5200 1556x221x95

22315 L 562x36 HF 2US 71 6700 1256x221x95

22316 L 562x58 HF 2US 109 10400 1556x221x95

L<200 cd/m² 65°

E>62%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 560 T8 2MG

Code 22304

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

22300 L 561x18 HF 2MG 19 1350 647x221x95

22303 L 562x18 HF 2MG 35 2700 647x221x95

22301 L 561x36 HF 2MG 36 3350 1256x221x95

22302 L 561x58 HF 2MG 55 5200 1556x221x95

22304 L 562x36 HF 2MG 71 6700 1256x221x95

22305 L 562x58 HF 2MG 109 10400 1556x221x95

L 560 Fluo

L<1000 cd/m² 65°

E>65%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 216: 3F Filippi  "General catalogue 2016"

213Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 560 T8 2S

Code 22334

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

22330 L 561x18 HF 2S 19 1350 647x221x95

22333 L 562x18 HF 2S 35 2700 647x221x95

22331 L 561x36 HF 2S 36 3350 1256x221x95

22332 L 561x58 HF 2S 55 5200 1556x221x95

22334 L 562x36 HF 2S 71 6700 1256x221x95

22335 L 562x58 HF 2S 109 10400 1556x221x95

L<1000 cd/m² 65°

E>60%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

L 560 T5 2S

Code 27546

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

27544 L 561x14 T5 LD HF 2S 16 1200 647x221x95

27549 L 562x14 T5 LD HF 2S 31 2400 647x221x95

27545 L 561x28 T5 LD HF 2S 31 2600 1256x221x95

27547 L 561x35 T5 LD HF 2S 38 3300 1556x221x95

27548 L 561x49 T5 LD HF 2S 53 4300 1556x221x95

27546 L 561x54 T5 LD HF 2S 58 4450 1256x221x95

27550 L 562x28 T5 LD HF 2S 60 5200 1256x221x95

27552 L 562x35 T5 LD HF 2S 76 6600 1556x221x95

27553 L 562x49 T5 LD HF 2S 106 8600 1556x221x95

27551 L 562x54 T5 LD HF 2S 114 8900 1256x221x95

L 560 Fluo

L<200 cd/m² 65°

E>63%

1x - Average luminance <200 cd/m² for radial angles >65°.2x - Average luminance <1000 cd/m² for radial angles >65°.2S parabolic louvre in semi-specular aluminium, non-reflecting, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 217: 3F Filippi  "General catalogue 2016"

214

L 560 T8 SP

Code 22370

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

22368 L 561x18 HF SP 19 1350 647x221x95

22371 L 562x18 HF SP 35 2700 647x221x95

22369 L 561x36 HF SP 36 3350 1256x221x95

22370 L 561x58 HF SP 55 5200 1556x221x95

22372 L 562x36 HF SP 71 6700 1256x221x95

22373 L 562x58 HF SP 109 10400 1556x221x95

Overall IP54 version. Installation by hanging from rough ceiling. - EEI A2 electronic wiring - Lamps not included

22376 L 561x18 HF IP54 SP 19 1350 647x221x95

22378 L 562x18 HF IP54 SP 35 2700 647x221x95

22377 L 561x36 HF IP54 SP 36 3350 1256x221x95

22379 L 562x36 HF IP54 SP 71 6700 1256x221x95

L 560 Fluo

E>57%

1x - Average luminance <3000 cd/m² for radial angles >65°.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.Sealing gasket for IP54 totally protected luminaires.

Page 218: 3F Filippi  "General catalogue 2016"

215Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Head fixings bracket for installation of the luminaire on load bearing structures (transverse by the luminaire).Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0176 15XB

The bracket protruding 55 mm beyond the head side.Excursion min. 20 mm, max. 40 mm.

Head fixings bracket for installation of the luminaire on load bearing structures (transverse by the luminaire).Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0175 15GF

The bracket protruding 60 mm beyond the head side.Excursion min. 40 mm, max. 60 mm.

Head fixings bracket for installation of the luminaire on load bearing structures (transverse by the luminaire).Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0174 15DP

The bracket protruding 55 mm beyond the head side.Excursion min. 60 mm, max. 80 mm.

Fixing bracket for pull-up installation on mineral fiber panels with low recessing space or on plasterboard.Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0177 15ZH

Brackets for lay-installation on load bearing side profiles parallel to the luminaire.Excursion min. 45 mm, max. 72 mm.

Accessories

L 560

Fixing bracket for ceiling pull-up installation.Not suitable for IP54 recessed luminaires.Pack for 1 luminaire.

Code Item

A0170 15BS

Brackets for lay-installation on load bearing side profiles parallel to the luminaire (excursion min. 18 mm, max. 45 mm).

Page 219: 3F Filippi  "General catalogue 2016"

216

L 580 LED IP54VLED luminaire with increased ingress protection

Construction characteristics

Illuminotechnical characteristicsAverage luminance <3000 cd/m² for radial angles >65°.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing in white painted steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Environments: hospital premises, aseptic, sterilized, laboratories.Environments requiring a high level of protection, high levels of light, source shielding and simplified cleaning.

Source characteristics

• Squared LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• sources in different powers or colour temperatures

• wiring: dimmable, emergency

Accessories

Accessories on page 222.

12.5A = L

H6

Standard

A = L

H6

BL

25

Page 220: 3F Filippi  "General catalogue 2016"

217Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 580 LED SP

Code 21440

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21440 L 580 32W LED SP 596x596 34 3672 596x596x100

Wide edge - Electronic

21447 L 580 32W LED BL SP 621x621 34 3672 621x621x100

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.BL version with wide edge.

L 580 LED VS

Code 21454

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

21454 L 580 32W LED VS 596x596 34 3480 596x596x100

Wide edge - Electronic

21461 L 580 32W LED BL VS 621x621 34 3480 621x621x100

L 580 LED IP54V

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Anti-glare microprismatic VS moulded glass, tempered, not flammable, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.BL version with wide edge.

Page 221: 3F Filippi  "General catalogue 2016"

218

L 580 Fluo IP54Luminaire with increased ingress protection

Construction characteristics

Mechanical characteristicsHousing in white painted steel.RVS flux recuperator and glass, non-combustible, thickness 4 mm, tempered, locked to the white aluminium perimeter frame, sealing gasket, hinged opening.Flux recuperator and diffuser in RSP transparent PMMA, prismatic exterior, anti-glare, locked to the white aluminium perimeter frame, sealing gasket, hinged opening.2US VT louvre and glass, in semi-glossy aluminium, antiglare lamp, with transverse blades closed at the top, and non-combustible glass, thickness 4 mm, tempered, locked to the white aluminium perimeter frame, sealing gasket, hinged opening.Total IP54 protection degree.

Dimensions

changes, and in general in any environments requiring total protection against falling fragments, use use on request versions L 580 RP with polycarbonate diffuser or specific luminaires with laminated glass (see series L 350 and L 590) with appropriate frame.

Installation

Hanging from rough ceiling for panels with concealed structure or plasterboard, lay-installation for panels with exposed structure.3x55C version for panels with exposed structure.

Source characteristics

• Fluorescent compact lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• RSP PC polycarbonate diffuser• fuse accessory (on page 472)• wiring: dimmable, emergency

Applications

Environments: hospital premises, aseptic, sterilised rooms, laboratories.Environments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.In environments with foodstuffs or machines with parts in motion, with considerable sudden temperature

H612.5

A12.5

A

612.5

L

6

25A

6H

256

A25

A

12.5A = L

H

6

12.56

6

Page 222: 3F Filippi  "General catalogue 2016"

219Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 580 RVS

Code 2532

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps supplied

2532 L 583x55 C LD HF CR RVS 178 12900 596x596x145

E>64%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.Fast connection, housing with slot and polycarbonate cover, M20x1.5 cable gland to access the terminal block.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

L 580 T5 RVS MultiWatt

Code 27640

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

27640 L 584x14-24 T5 HF DA RVS 62-98 4800-7000 596x596x95

27643 L 582x28-54 T5 HF RVS 60-114 5200-8900 1196x296x95

Wide edge - Electronic MultiWatt EEI A2 - Lamps not included

27661 L 584x14-24 T5 HF DA BL RVS 62-98 4800-7000 621x621x95

27664 L 582x28-54 T5 HF BL RVS 60-114 5200-8900 1221x321x95

L 580 Fluo IP54

E>61%

Flow recuperator in white painted steel, high reflection.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit in 4x14-24 version.BL version with wide edge.

Page 223: 3F Filippi  "General catalogue 2016"

220

L 580 T5 2US VT MultiWatt

Code 27682

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

27682 L 584x14-24 T5 HF DA CR 2US VT 62-98 4800-7000 596x596x145

L<1000 cd/m² 65°

E>58%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Transparent glass VT tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.Fast connection, housing with slot and polycarbonate cover, M20x1.5 cable gland to access the terminal block.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit.

L 580 T5 RSP MultiWatt

Code 27724

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

27724 L 584x14-24 T5 HF DA RSP 62-98 4800-7000 596x596x95

27727 L 582x28-54 T5 HF RSP 60-114 5200-8900 1196x296x95

Wide edge - Electronic MultiWatt EEI A2 - Lamps not included

27745 L 584x14-24 T5 HF DA BL RSP 62-98 4800-7000 621x621x95

27748 L 582x28-54 T5 HF BL RSP 60-114 5200-8900 1221x321x95

L 580 Fluo IP54

E>61%

Flow recuperator in white painted steel, high reflection.SP transparent PMMA diffuser, prismatic exterior, anti-glare, locked to the prepainted white aluminium perimeter frame with sealing gasket, hinged opening.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit in 4x14-24 version.BL version with wide edge.

Page 224: 3F Filippi  "General catalogue 2016"

221Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 580 2US VT

Code 2534

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2534 L 583x55 C LD HF CR 2US VT 178 12900 596x596x145

L 580 Fluo IP54

L<1000 cd/m² 65°

E>55%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Transparent glass VT tempered, non-combustible, thickness 4 mm, locked to the white painted aluminium perimetrical frame, sealing gasket, hinged opening.Fast connection, housing with slot and polycarbonate cover, M20x1.5 cable gland to access the terminal block.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

Page 225: 3F Filippi  "General catalogue 2016"

222

Fixing bracket for pull-up installation on mineral fiber panels or on plasterboard.Pack for 1 luminaire.

Code Item

A0173 15HI

Excursion min. 17 mm, max. 52 mm.Can only be used with the model L 580 LED IP54V.

Accessories

L 580

Fixing bracket for pull-up installation on mineral fiber panels or on plasterboard.Pack for 1 luminaire.

Code Item

A0177 15ZH

Excursion min. 34 mm, max. 69 mm.Can only be used with the model L 580 LED IP54V.

Page 226: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 227: 3F Filippi  "General catalogue 2016"

224

L 590 Fluo IP65Luminaire with high ingress protection and excellent visual comfort

Construction characteristics

Mechanical characteristicsHousing in white painted steel.Perimetrical frame in white painted stainless steel, sealing gasket, hinged opening, stainless steel closing screws.RVS version with flow recuperator in high-reflecting aluminium and moulded tempered glass.2US VT version with parabolic louvre with transverse blades closed at the top and tempered transparent glass.Total IP65 protection degree.

Source characteristics

• 55W compact fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

Dimensions

Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.RVS versionEnvironments requiring a high level of protection, high levels of light, lamp shielding and simplified cleaning.2US VT versionEnvironments with exacting visual tasks, where diffused soft light for optimum visual comfort is required.

Installation

Hanging from rough ceiling for panels with concealed or exposed structure and plasterboard.

On request

• lamps in different powers or colour temperatures

• transparent laminated glass• fixing brackets (advise the false ceiling type)• fuse accessory (on page 472)• wiring: dimmable, emergency• luminaires with electronic wiring, in

compliance with 94/9/CE (ATEX) standard, group II, category 3D, for Zone 22

Applications

Environments: hospital premises, transit areas, laboratories, platform-roof, underpasses.Environments: sterilized, aseptic.In hospital environments, food industry or machines with parts in motion, with considerable sudden temperature changes, and in general in any environments requiring total protection against falling fragments, use luminaires with laminated glass only.

H

A33

A33

L33

33A = L

33

H

H

Page 228: 3F Filippi  "General catalogue 2016"

225Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

L 590 RVS

Code 2578

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2578 L 593x55C HF RVS 178 12900 599x599x145

E>60%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted stainless steel perimetrical frame, sealing gasket, hinged opening.Stainless steel closing screws.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

L 590 T5 RVS MultiWatt

Code 27902

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

27902 L 594x14-24 T5 HF DA RVS 62-98 4800-7000 599x599x145

27907 L 592x28-54 T5 HF RVS 60-114 5200-8900 1199x299x95

27903 L 594x28-54 T5 HF DA RVS 120-228 10400-17800 1199x599x95

L 590 Fluo IP65

E>60%

Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VS moulded glass, anti-glare, tempered, non-combustible, thickness 4 mm, locked to the white painted stainless steel perimetrical frame, sealing gasket, hinged opening.Stainless steel closing screws.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit.

Page 229: 3F Filippi  "General catalogue 2016"

226

L 590 2US VT

Code 2589

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

2589 L 593x55C HF 2US VT 178 12900 599x599x145

L<1000 cd/m² 65°

E>55%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Transparent glass VT tempered, non-combustible, thickness 4 mm, locked to the white painted stainless steel perimetrical frame, sealing gasket, hinged opening.Stainless steel closing screws.EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.

L 590 T5 2US VT MultiWatt

Code 27919

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

27919 L 594x14-24 T5 HF DA 2US VT 62-98 4800-7000 599x599x145

L 590 Fluo IP65

L<1000 cd/m² 65°

E>55%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Transparent glass VT tempered, non-combustible, thickness 4 mm, locked to the white painted stainless steel perimetrical frame, sealing gasket, hinged opening.Stainless steel closing screws.EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Twin-circuit in 4x versions.

Page 230: 3F Filippi  "General catalogue 2016"

227Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Accessories

L 590

Anti-condensation diffuser cable gland.

Code Item

A0187 Anti-condensation cable gland

Recommended for installations in environments with temperature sudden changes or subject to condensation.

Page 231: 3F Filippi  "General catalogue 2016"

228

Barraluce L LEDLED channel system for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in white painted extruded aluminium.Removable gear-tray, functions as flux recuperator, in specular aluminium, high efficiency, with titanium-magnesium surface treatment, non-iridescent.OP flat diffuser in opal PMMA.SP flat diffuser in prismatic PMMA.

Electrical characteristicsElectronic wiring 230V-50/60Hz.1+1 wiring in twincircuit.Head entrance feeding.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.In compliance with EN 60598-1.

Dimensions

Applications

Environments: with VDTs, meeting rooms, offices.Environments: architectural, commercial, staterooms, banks.Environments where dynamic, soft and diffuse light is required for optimal visual comfort.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• wiring: dimmable, emergency• possibility to create lighting corners• micro-prismatic diffuser

Accessories

Accessories on page 236.

A

L

L

H

Single

Channel

Page 232: 3F Filippi  "General catalogue 2016"

229Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Barraluce L LED Opal - Channel

Code 269356

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

269354 Barraluce L 1x30W LED OP 5P L1466 34 3513 1466x140x100

269356 Barraluce L 1+1x30W LED OP 5P L2932 68 7026 2932x140x100

E=100%

Luminaire for continuous channel installation (end caps not included).OP opal methacrylate flat diffuser, anti-glare.

Barraluce L LED Opal - Single

Code 269346

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

269346 Barraluce L 1x30W LED OP L1496 34 3513 1496x140x100

269348 Barraluce L 1+1x30W LED OP L2962 68 7026 2962x140x100

Barraluce L LED

E=100%

Luminaire for standalone installation with aluminium end caps (included).OP opal methacrylate flat diffuser, anti-glare.

Page 233: 3F Filippi  "General catalogue 2016"

230

Barraluce L LED SP - Channel

Code 269340

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

269338 Barraluce L 1x30W LED SP 5P L1466 34 3798 1466x140x100

269340 Barraluce L 1+1x30W LED SP 5P L2932 68 7596 2932x140x100

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Luminaire for continuous channel installation (end caps not included).SP flat diffuser in PMMA transparent prismatic methacrylate, anti-glare.

Barraluce L LED SP - Single

Code 269330

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

269330 Barraluce L 1x30W LED SP L1496 34 3798 1496x140x100

269332 Barraluce L 1+1x30W LED SP L2962 68 7596 2962x140x100

Barraluce L LED

L<3000 cd/m² 65°

E=100%

Average luminance <3000 cd/m² for radial angles >65°.Luminaire for standalone installation with aluminium end caps (included).SP flat diffuser in PMMA transparent prismatic methacrylate, anti-glare.

Page 234: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 235: 3F Filippi  "General catalogue 2016"

232

Barraluce L Opal FluoFluorescent luminaire with high visual comfort

Construction characteristics

Illuminotechnical characteristicsDirect diffused symmetric distribution.

Mechanical characteristicsHousing in white painted extruded aluminium.Removable gear-tray in white painted steel.OP flat diffuser in opal PMMA.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Head entrance feeding.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.Lamps excluded.

Dimensions

Applications

Environments: architectural, commercial, staterooms, lobbies or waiting rooms, corridors.Environments where demanding visual tasks are performed and comfortable lighting is required.

On request

• fuse accessory (on page 472)• wiring: dimmable, emergency• micro-prismatic diffuser

Accessories

Accessories on page 236.

L

L

L

L

A

HSingle

IFC 1x

IFC 1+1x

IC

Page 236: 3F Filippi  "General catalogue 2016"

233Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Barraluce L Opal - Channel

Code 265014

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

IFC Start/End Channel - Electronic MultiWatt EEI A2 - Lamps not included

265007 Barraluce L 1x28-54 T5 HF OP IFC 5P 31-58 2600-4450 1122x140x100

265014 Barraluce L 1x35-49-80 T5 HF OP IFC 5P 38-53-86 3300-4300-6150 1422x140x100

265021 Barraluce L 1+1x28-54 T5 HF OP IFC 5P 60-114 5200-8900 2191x140x100

265028 Barraluce L 1+1x35-49-80 T5 HF OP IFC 5P 76-106-170 6600-8600-12300 2791x140x100

IC Channel Intermediate - Electronic MultiWatt EEI A2 - Lamps not included

265879 Barraluce L 1+1x28-54 T5 HF OP IC 5P 60-114 5200-8900 2138x140x100

265886 Barraluce L 1+1x35-49-80 T5 HF OP IC 5P 76-106-170 6600-8600-12300 2738x140x100

E>57%

Luminaire for continuous channel installation (end caps not included).OP opal methacrylate flat diffuser, anti-glare.

Barraluce L Opal - Single

Code 260182

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

260171 Barraluce L 1x28-54 T5 HF OP 31-58 2600-4450 1201x140x100

260182 Barraluce L 1x35-49-80 T5 HF OP 38-53-86 3300-4300-6150 1501x140x100

260565 Barraluce L 2x28-54 T5 HF OP 60-114 5200-8900 1201x140x100

260572 Barraluce L 2x35-49-80 T5 HF OP 76-106-170 6600-8600-12300 1501x140x100

Barraluce L Opal Fluo

E>57%

Luminaire for standalone installation with aluminium end caps.OP opal methacrylate flat diffuser, anti-glare.

Page 237: 3F Filippi  "General catalogue 2016"

234

Barraluce L 2MG FluoFluorescent luminaire with luminance control

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.

Mechanical characteristicsHousing in white painted extruded aluminium.Removable gear-tray in white painted steel.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, attached to louvre.

Electrical characteristicsEEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Head entrance feeding.Channel luminaires: through-wiring, 5-pole, 2.5mm² section with irreversible fastconnection plug/socket, with irreversible fast-connection socket for branch, connecting to the socket positioned on the gear-tray unit.Lamps excluded.

Dimensions

Applications

Environments: architectural, commercial, staterooms, with VDTs, banks, shops, offices.Environments where demanding visual tasks are performed and comfortable lighting is required.

On request

• fuse accessory (on page 472)• wiring: dimmable, emergency

Accessories

Accessories on page 236.

A

HL

Single

IFC 1x

IFC 1+1x

IC

L

L

L

Page 238: 3F Filippi  "General catalogue 2016"

235Datasheets, product updates and specifications on our website: www.3f-filippi.com

Recessed

lum

inaires

Barraluce L 2MG - Channel

Code 268011

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

268004 Barraluce L 1x28-54 T5 HF 2MG 5P 31-58 2600-4450 1171x140x100

268011 Barraluce L 1x35-49-80 T5 HF 2MG 5P 38-53-86 3300-4300-6150 1471x140x100

268018 Barraluce L 1+1x28-54 T5 HF 2MG 5P 60-114 5200-8900 2342x140x100

268025 Barraluce L 1+1x35-49-80 T5 HF 2MG 5P 76-106-170 6600-8600-12300 2942x140x100

L<1000 cd/m² 65°

E>77%

Average luminance <1000 cd/m² for radial angles >65°.Luminaire for continuous channel installation (end caps not included), with light continuity even in the junction.2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Barraluce L 2MG - Single

Code 263071

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

263060 Barraluce L 1x28-54 T5 HF 2MG 31-58 2600-4450 1201x140x100

263071 Barraluce L 1x35-49-80 T5 HF 2MG 38-53-86 3300-4300-6150 1501x140x100

263455 Barraluce L 2x28-54 T5 HF 2MG 60-114 5200-8900 1201x140x100

263462 Barraluce L 2x35-49-80 T5 HF 2MG 76-106-170 6600-8600-12300 1501x140x100

Barraluce L 2MG Fluo

L<1000 cd/m² 65°

E>77%

Average luminance <1000 cd/m² for radial angles >65°.Luminaire for standalone installation with aluminium end caps (included).2MG parabolic louvre, high efficiency, in specular aluminium with superficial titanium-magnesium treatment, non-iridescent, with transverse blades closed at the top.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 239: 3F Filippi  "General catalogue 2016"

236

Terminal block (plug/socket) with irreversible snap-in double clamp, for power-supply connection at beginning and end of the channel, 5 poles.

Code Item

A02484 5P socket/plug terminal block Beginning/End Channel

Pair of end caps for channels, in white painted aluminium, with screws for fixing to housing, always required.Thickness: 15 mm each cap.

Code Item

A01417 Pair end caps Barraluce L channel diffuser

A01418 Pair end caps Barraluce L channel louvre

Linear connecting elements in hotgalvanised steel with grub screws for fast and rigid installation.

Code Item

A01423 Linear connecting elements Barraluce

Brackets for installing the product on platerboard.

Code Item

A01420 New Couple brackets for Barraluce L

Accessories

Barraluce L

Free-position sliding bracket in stainless steel.

Code Item

A0483 Sliding bracket Barraluce L

To be used with inspectable false-ceilings.

Page 240: 3F Filippi  "General catalogue 2016"

Recessed

lum

inaires

Page 241: 3F Filippi  "General catalogue 2016"
Page 242: 3F Filippi  "General catalogue 2016"

239

Syste

ms

News and updates available on: www.3f-filippi.com > Products > Systems

SystemsPage Product Source Screen Optic Lens

240 3F Linux246 New 3F Linux S -

248 New 3F Linux L LED •

254 New 3F Linux D LED •

256 New 3F Linux DR LED •

262 Binario 3F264 New Binario 3F LED

270 3F Rocket270 New 3F Rocket M LED •

272 New 3F Rocket L LED •

275 3F Fil276 New 3F Fil LED LED • •

Page 243: 3F Filippi  "General catalogue 2016"

240

3F Linu

x L

3F Linu

x D

Simply modular

3F Linux is a modular system designed to allow you to compose channels as simply and efficiently as possible.

Like all products in the 3F Filippi range, it is fitted with high-efficiency LED sources and features a compact body, modular components and accessories which give unrivalled freedom in terms of planning the installations.

3F Linux

Page 244: 3F Filippi  "General catalogue 2016"

241

Syste

ms

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F Linux

Product strengths

• System for the creation and composition of channels which combines the various electrical requirements with the specific lighting design requirements.

• When installed, it disappears from sight due to its clean, minimalist lines offering high performance. • Its flexibility lends it to installation in commercial environments requiring high levels of lighting, and in circulation areas where it can be

installed invisibly even in corners.• Quick and easy installation• Optimised light distribution for many different applications.• Lengths of the structures and lighting units optimised in order to reduce installation times and investment (-20 % accessories to be

purchased and installed with respect to standard lengths).• All mechanical and electrical installation phases are tool free.• Easy maintenance• Sliding bracket on the structure• Quick adjuster for fast levelling• Connecting element already fitted • Through line up to 11 poles with power-supply pedestal and through plug/socket.• Dual hidden springs for support and to prevent the lamp from falling, for maximum protection against accidental falls.• Possibility of lighting units with different louvres, translucent polycarbonate diffusers and closing covers.• Lighting units with different power ratings and cable types, integrated sensors also possible.

Page 245: 3F Filippi  "General catalogue 2016"

242

1 2

3F Linux S62

36

64

67

3F Linux L

3F LinuxSimply modular

The FastWiring system reduces the time necessary to create a lighting channel:

Install the structures,

connecting them

together with the

connecting elements

(pre-fitted) and connect

the power-supply lines

Connect the power-

supply plug and secure

the lighting element to the

structure, moving it to the

required point

Scale 1: 1 - Dimensions in mm

Structure lengths

optimized to reduce the

number of components

in long compositions.

Page 246: 3F Filippi  "General catalogue 2016"

243

3

64

3F Linux DR

82

3F Linux D64

Syste

ms

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Installation requires just 3 steps, with no tools needed.

Once you have chosen

the required position,

secure the lighting

element to the structure

until the retaining spring

clicks

3F Linux

Page 247: 3F Filippi  "General catalogue 2016"

244

3F LinuxSimply modular

Closing end

always necessary3F Linux S

3F Linux L

3F Linux D

3F Linux DR

High closing top

Low closing top

Structure

Light unit

Light unit

Light unit

Page 248: 3F Filippi  "General catalogue 2016"

245

Syste

ms

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F LinuxGuide to the composition of the light channels

Structure length (meters)

Item 3,56 5,33 7,11 8,89 10,67 12,45 14,22 16,00 17,78 19,56 21,34 23,11 24,89 26,67 28,45 30,23 35,56 40,89

3F Linux S 5P/7P L3556 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 10 11

3F Linux S 5P/7P L1778 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1 0 1

Lighting units 3F Linux L-D-DR L1778 2 3 4 5 6 7 8 9 10 11 12 13 14 14 16 17 20 23

Pair of closing end 3F Linux 1

Sliding bracket 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 13

5-poles socket-pin terminal block

3F Linux S 5P/7P1

Suspension without adjustment for 3F

Linux2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 13

Connection to the earth 0 0 0 1 1 1 2 2 2 2 2 2 2 2 2 3 3 3

The number of sliding brackets and suspensions is calculated foreseeing 2 pieces for the first bar and 1 for the following that is composing the channel.

The installer must verify if, because of existing structural constraints, the number of items should be increased.

Optional components: these components can replace (even-numbered) the standard ones, performing equivalent functions.

Structure length (meters)

Item 3,56 5,33 7,11 8,89 10,67 12,45 14,22 16,00 17,78 19,56 21,34 23,11 24,89 26,67 28,45 30,23 35,56 40,89

Closing Top between 3F Linux L or D -

L17780

Central feeding 5-poles socket-pin

terminal block 3F Linux S 5P/7P1

Single contact pin 1

Stainless steel hook for chain 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 13

S-shaped chain hook with sliding

bracket 3F Linux 2 3 3 4 4 5 5 6 6 7 7 8 8 9 9 10 11 13

Note: Closing Top items is “zero” because it has the same total length of the light units (so it can replace them in equal measure).

Page 249: 3F Filippi  "General catalogue 2016"

246

New

3F Linux SModular structural system for LED lighting modules with high efficiency and electrical line transport.

Modular and flexible structural system with small dimensions to create continuous channels and compositions, transport electrical lines and fixing of various types of products.Quick and easy ceiling or pendant installation.

Construction characteristics

Illuminotechnical characteristicsDifferent lighting distributions depending by the lighting unit: L (optical lenses), D (curved diffuser), DR (Rectangular diffuser) and projectors or other types of luminaires.

Mechanical characteristicsHot-galvanised wired structure, painted in polyester base white, obtained through rolling process.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Linear connecting element in hot galvanized steel for the formation of continuous channels. Standard on L3556 versions (optional for other lengths).For the completion accessories, see the accessories page.

Electrical characteristicsThrough-wiring 5 or 7 poles with cables H07Z-U Halogen Free section 2.5 mm² HT90, with quick connecting terminal start / end channel, irreversible and intermediate power sockets.3 sockets for 3556 mm structures, 1 socket for 1778 mm structures (5P=N/T/1/2/3, 7P=N/T/1/2/3/+/-).Feeding input on top (at the beginning or in the middle of the structure).

Dimensions

Applications

Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.

On request

• structure and accessories in RAL color• through-wiring up to 11 poles

Accessories

Accessories on page 258.

A

H

L

L

Page 250: 3F Filippi  "General catalogue 2016"

247Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Linux S

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A20018 New 3F Linux S 5P L3556 3556x62x38

A20019 New 3F Linux S 5P L1778 1778x62x38

A20025 New 3F Linux S 7P L3556 3556x62x38

A20026 New 3F Linux S 7P L1778 1778x62x38

3F Linux S

Linear connecting element already mounted on L3556 versions.

Page 251: 3F Filippi  "General catalogue 2016"

248

New

3F Linux LLED light module with optical lenses for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsWide direct, concentrated and dual asymmetric (BAT) distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsLight unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.PMMA lenses with external flat surface (superimposed to obtain full protection of LED modules).

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Connection to the structure with mobile plug with phase selection (H05Z-U Halogen Free cable section 0,5mm² HT90).

Dimensions

Installation

This lighting unit can be installed only on profile 3F Linux S (see dedicated product pages).

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers• LED sources with different colour

temperatures• mantained emergency• integrated light sensor

Applications

Ambient temperatures up to +25°C.Environments: industrial, commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops.

A

H

L

Page 252: 3F Filippi  "General catalogue 2016"

249Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Linux L BAT

Code A20085

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

A20085 New 3F Linux L 40 LED BAT L1778 42 6142 1778x62x32

A20084 New 3F Linux L 50 LED BAT L1778 53 7294 1778x62x32

A20083 New 3F Linux L 60 LED BAT L1778 65 8600 1778x62x32

DALI electronic

A20099 New 3F Linux L 40 LED DALI BAT L1778 42 6142 1778x62x32

A20098 New 3F Linux L 50 LED DALI BAT L1778 53 7294 1778x62x32

A20097 New 3F Linux L 60 LED DALI BAT L1778 65 8600 1778x62x32

E=100%

Double symmetrical distribution.Structure height (3F Linux S + 3F Linux L) equal to 67 mm.

3F Linux L Wide

Code A20127

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

A20127 New 3F Linux L 40 LED AMPIO L1778 42 6155 1778x62x32

A20126 New 3F Linux L 50 LED AMPIO L1778 53 7309 1778x62x32

A20125 New 3F Linux L 60 LED AMPIO L1778 65 8618 1778x62x32

DALI electronic

A20141 New 3F Linux L 40 LED DALI AMPIO L1778 42 6155 1778x62x32

A20140 New 3F Linux L 50 LED DALI AMPIO L1778 53 7309 1778x62x32

A20139 New 3F Linux L 60 LED DALI AMPIO L1778 65 8618 1778x62x32

3F Linux L

E=100%

Wide distribution.Structure height (3F Linux S + 3F Linux L) equal to 67 mm.

Page 253: 3F Filippi  "General catalogue 2016"

250

3F Linux L Concentrated

Code A20167

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

A20167 New 3F Linux L 60 LED CONC L1778 65 8468 1778x62x32

DALI electronic

A20181 New 3F Linux L 60 LED DALI CONC L1778 65 8468 1778x62x32

3F Linux L

E=100%

Wide distribution with rectangular shape.Structure height (3F Linux S + 3F Linux L) equal to 67 mm.

Page 254: 3F Filippi  "General catalogue 2016"

251Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

Page 255: 3F Filippi  "General catalogue 2016"

252

1122570

952

483

801

407

1120

562

950

477

800

401

948

480

804

407

677

343

828420

702

356

591

300

1100

561

933

476

786

401

944

481

801

408

674

344

824420

699

356

589

300

735378

623

321

525

270

1093

555

927

471

781

396

936

476

794

404

668

340

818416

694

353

584

297

730 371

619

315

521

265

659337

559

286

471

241

1098

559

931

474

784

399

939

480

796

407

671

343

821418

696

355

586

299

731373

620

316

522

266

656335

556

284

469

239

602307

511

260

430

219

3F Linux LDesign reference tables - Installation ACROSS aisles

Design data:

Maintenance factor K = 0.85

Reflection ceiling 50% walls 50% floor 40%

Shelves height 2.20 meters reflection 40%

Work surface height 0.85 meters

Aisle width 2 meters

Luminaire: 3F Linux L 60 AMPIO

Luminaire: 3F Linux L 50 AMPIO

Luminaire: 3F Linux L 40 AMPIO

Installation spacing(meters)

Calculation surface Installation height (meters)

3 3,5 4 4,5 5

3Horizontal aisle

Vertical shelf

3,5Horizontal aisle

Vertical shelf

4Horizontal aisle

Vertical shelf

4,5Horizontal aisle

Vertical shelf

5Horizontal aisle

Vertical shelf

5,5Horizontal aisle

Vertical shelf

Installation spacing(meters)

Calculation surface Installation height (meters)

3 3,5 4 4,5 5

3Horizontal aisle

Vertical shelf

3,5Horizontal aisle

Vertical shelf

4Horizontal aisle

Vertical shelf

4,5Horizontal aisle

Vertical shelf

5Horizontal aisle

Vertical shelf

5,5Horizontal aisle

Vertical shelf

Installation spacing(meters)

Calculation surface Installation height (meters)

3 3,5 4 4,5 5

3Horizontal aisle

Vertical shelf

3,5Horizontal aisle

Vertical shelf

4Horizontal aisle

Vertical shelf

4,5Horizontal aisle

Vertical shelf

5Horizontal aisle

Vertical shelf

5,5Horizontal aisle

Vertical shelf

Not recommended

Wide distrib.

The values in the tables

are given in lux (lx).

Notes:

Page 256: 3F Filippi  "General catalogue 2016"

253

Syste

ms

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Luminaire: 3F Linux L AMPIO

Luminaire: 3F Linux L BAT

Luminaire: 3F Linux L CONC

Luminaire power Calculation surface Installation height (meters)

3 3,25 3,5 3,75 4

60 AMPIOHorizontal aisle

Vertical shelf

1363

814

1210

746

1124

664

1040

599

992

548

50 AMPIOHorizontal aisle

Vertical shelf

1156

690

1026

633

953

563

882

508

841

465

40 AMPIOHorizontal aisle

Vertical shelf

973

581

864

533

803

474

743

428

708

391

Luminaire power Calculation surface Installation height (meters)

3 3,25 3,5 3,75 4

60 BATHorizontal aisle

Vertical shelf

1315

831

1169

806

1042

770

930

740

862

691

50 BATHorizontal aisle

Vertical shelf

1115

705

991

684

884

653

789

628

731

586

40 BATHorizontal aisle

Vertical shelf

939

594

835

576

744

550

664

529

616

494

Luminaire power Calculation surface Installation height (meters)

5 6 7 8

60 CONCHorizontal aisle

Vertical shelf

1285

413

1102

380

950

349

834

321

3F Linux LDesign reference tables - Installation ALONG aisles UP to 5 meters height.

Design data:

Maintenance factor K = 0.85

Reflection ceiling 50% walls 50% floor 40%

Shelves height 2.20 meters reflection 40%

Work surface height 0.85 meters

Aisle width 2 meters

Notes:

The values in the tables

are given in lux (lx).

Design reference tables - Installation ALONG aisles OVER 5 meters height.Design data:

Reflectionceiling 50%walls 50%floor 40%

Shelvesheight 4,5 / 5,5 / 6,5 / 7,5 metersreflection 40%

Work surface height 0,85 meters

Aisle width 2 meters

Page 257: 3F Filippi  "General catalogue 2016"

254

New

3F Linux DLED light module with curved diffuser for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsLight unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Curved screen in self-extinguishing polycarbonate, UV stabilized, opal, with smooth outer surface.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Connection to the structure with mobile plug with phase selection (H05Z-U Halogen Free cable section 0,5mm² HT90). Dimensions

Installation

This lighting unit can be installed only on profile 3F Linux S (see dedicated product pages).

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• asymmetric lighting distribution• different powers• LED sources with different colour

temperatures• mantained emergency

Applications

Ambient temperatures up to +25°C.Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.

A

H

L

Page 258: 3F Filippi  "General catalogue 2016"

255Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Linux D

Code A20336

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

A20336 New 3F Linux D 2x22 LED L1778 50 5859 1778x62x47

A20335 New 3F Linux D 2x30 LED L1778 68 7389 1778x62x47

DALI electronic

A20350 New 3F Linux D 2x22 LED DALI L1778 50 5859 1778x62x47

A20349 New 3F Linux D 2x30 LED DALI L1778 68 7389 1778x62x47

3F Linux D

E=100%

Diffuse distribution.Structure height (3F Linux S + 3F Linux D) equal to 82 mm.

Page 259: 3F Filippi  "General catalogue 2016"

256

New

3F Linux DRLED light module with a rectangular diffuser for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsLight unit in hot-galvanized steel, painted in white polyester base with fixing springs and retractable safety hooks in stainless steel.Saline-mist resistance equal to 500hrs and damp resistance equal to 700hrs.Rectangular screen in self-extinguishing polycarbonate, UV stabilized, opal, with smooth outer surface.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Connection to the structure with mobile plug with phase selection (H05Z-U Halogen Free cable section 0,5mm² HT90). Dimensions

Installation

This lighting unit can be installed only on profile 3F Linux S (see dedicated product pages).

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• asymmetric lighting distribution• different powers• LED sources with different colour

temperatures• mantained emergency

Applications

Ambient temperatures up to +25°C.Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.

A

H

L

Page 260: 3F Filippi  "General catalogue 2016"

257Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Linux DR

Code A20512

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

A20512 New 3F Linux DR 2x22 LED L1778 50 5874 1778x62x47

A20511 New 3F Linux DR 2x30 LED L1778 68 7407 1778x62x47

DALI electronic

A20526 New 3F Linux DR 2x22 LED DALI L1778 50 5874 1778x62x47

A20525 New 3F Linux DR 2x30 LED DALI L1778 68 7407 1778x62x47

3F Linux DR

E=100%

Diffuse distribution.Structure height (3F Linux S + 3F Linux DR) equal to 82 mm.

Page 261: 3F Filippi  "General catalogue 2016"

258

Suspensions for 3F Linux without controller, galvanized steel cable 1.5 mm diameter, load 15 kg.

Code Item

A20486 New Suspension without adjustment for 3F Linux - 1m

A20487 New Suspension without adjustment for 3F Linux - 2 m

A20488 New Suspension without adjustment for 3F Linux - 3 m

A20489 New Suspension without adjustment for 3F Linux - 4 m

A20490 New Suspension without adjustment for 3F Linux - 5 m

A20491 New Suspension without adjustment for 3F Linux - 6 m

In the case of purchase of only one sliding bracket with controller (code A20450), the suspension cable must be made of galvanized steel with 49 elementary wires of minimum 1.5 mm diameter (for a weight of 15 kg) and 2 mm (for a weight of 25 kg).

Hook to suspended luminaires to a chain.

Code Item

A20452 New Stainless steel hook for chain

Safety screw for locking the sliding bracket, made of hot galvanized steel.

Code Item

A20474 New Safety screw for locking the sliding bracket

Concealed sliding bracket for free positioning, made of stainless steel.

Code Item

A20453 New S-shaped chain hook with sliding bracket 3F Linux

Supplied with S-hook for galvanized steel chain.

Accessories

3F Linux

Concealed sliding bracket for free positioning, made of stainless steel.

Code Item

A20450 New Sliding bracket with regulator for suspension installation

A20451 New Sliding bracket for ceiling installation

In the case of purchase of only one sliding bracket with controller (code A20450), the suspension cable must be made of galvanized steel with 49 elementary wires of minimum 1.5 mm diameter (for a weight of 15 kg) and 2 mm (for a weight of 25 kg).

Page 262: 3F Filippi  "General catalogue 2016"

259Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

Electric branch with plug-socket to realize L- or T-shaped connections.

Code Item

A20459 New 5-poles socket-pin branch (L-shaped) 3F Linux S

A20460 New 7-poles socket-pin branch (L-shaped) 3F Linux S

A20464 New 5-poles socket-pin branch (T-shaped) 3F Linux S

A20465 New 7-poles socket-pin branch (T-shaped) 3F Linux S

Elements to connect in between them 3F Linux S bars.

Code Item

A20433 New Linear connecting element for 3F Linux

A20434 New T-Connecting element for 3F Linux

A20436 New L-Connecting element 3F L Linux

Clamps in nickel-plated brass suitable for fixing and adjustment of galvanized steel wire (diameter 1.25 mm - 1.5 mm - 2 mm), complete with locking screws.The clamp with 2 holes allow to fix and adjust the cable on the carrier element (belonging to the building) or with eye screw fixing.

Code Item

A0714 New Clamp 2 holes - 100 pcs

Galvanized steel cable, diameter 1.5 mm, composed of 49 wires.15kg capacity (ratio 5: 1) in conjunction with cod. A20450.

Code Item

A0716 New Coil galvanized cable diam. 1.5mm - 100m

A0717 New Coil galvanized cable diam. 1.5mm - 500m

A0718 New Coil galvanized cable diam. 1.5mm - 1000m

These accessories must be ALWAYS used with one of the following cod.: A20450, A20451+A20452, A0622, A0714.

Accessories

3F Linux

Caddy hook to create a point from which to suspend the system or the loads to false ceilings with visible profiles.

Code Item

A02562 Caddy for exposed profiles of 24 mm

To be installed on exposed profiles (width 24 mm) of false ceilings.We recommend reinforcing the false-ceiling fixing at the point where the Caddy is to be installed.Supplied complete with nut and washer.The suspension must be purchased separately.

Page 263: 3F Filippi  "General catalogue 2016"

260

Terminal block plug-socket quick and irreversible graft, for electrical connection line.

Code Item

A20454 New 5-poles socket-pin terminal block 3F Linux S

A20455 New 7-poles socket-pin terminal block 3F Linux S

A20500 New Central feeding 5-poles socket-pin terminal block 3F Linux S

A20501 New Central feeding 7-poles socket-pin terminal block 3F Linux S

Brackets for the installation of luminaries on Linux S 3F bars (check the compatibility with our technical departments).Made of hot galvanized steel.

Code Item

A20470 New Pair of mounting brackets 3F devices on Linux S

Low closing top, made of impact-resistant white PVC.

Code Item

A20443 New Closing Top for luminaires - L1778

To be used with blind structures or when installing external luminaires (for example 3F Linda).

High closing top, made of impact-resistant white PVC.

Code Item

A20442 New Closing Top between 3F Linux L or D - L1778

For use when installing light modules 3F Linux L, D or DR.

Accessories

3F Linux

Pair of closing end 3F Linux S, made of white polycarbonate.

Code Item

A20448 New Pair of closing end 3F Linux

Page 264: 3F Filippi  "General catalogue 2016"

261Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

Additional contact for light unit plug.

Code Item

A20476 New Single contact pin

Power cable for luminaires not part of the 3F Linux system.

Code Item

A20479 New Power cable for luminaires, 3-pole

A20480 New Power cable for luminaires, 5-pole

Accessories

3F Linux

Connection to the earth, by means of galvanized M5 screw and nut, for Ø6 mm hole at the end of every structure.

Code Item

A0490 Connection to the earth

Page 265: 3F Filippi  "General catalogue 2016"

262

L2 L1

L3 N

DA DA

2

2

2

2

2

2

2

2

2

3

4

5

6

6

78

9

1

900 450 450

25 kg 50 kg

Binario 3FBusbar

Scale: 1:1

1 - Power-supply cap2 - Binario 3F busbar3 - Linear connecting element

4 - Flexible connecting element5 - Cross connector6 - L connector

7 - T connector8 - Central power supply9 - Closing cap

Structural elements

The versatility of this product allows the creation of ceiling-mount or suspended installations (within the limit of the maximum suspendable load limit).In compliance with EN 60570.

Characteristics

Binario 3F is an extruded aluminium busbar housing 6 conductors (4 for three-phase mode, 2 for DALI mode): the 3 phase conductors (with common neutral) form 3 distinct circuits, allowing 3 separate on commands. The conductors are enclosed in rigid extruded profiles made from high-rigidity insulating material.

Page 266: 3F Filippi  "General catalogue 2016"

263

Syste

ms

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Binario 3F

Defining the earth conductor position

Warning: as the track structure is asymmetrical because of the grounding element placed laterally, feeding heads and connecting joints must be chosen accordingly. In particular, this indication applies only to the following components:

In the S (LH) version, the conductor is located on the left when looking at the composition from above.

In the D (RH) version, the conductor is located on the right when looking at the composition from above.

In the EXT version, the conductor is located on the outside when looking at the composition from above.

In the INT version, the conductor is located on the inside when looking at the composition from above.

L connector

Power-supply cap

In the EXT + D (external + RHS) version, the third conductor is located on the right when looking at the composition from above.

In the INT + D (internal + RHS) version, the third conductor is located on the right when looking at the composition from above.

In the EXT + S (external + LHS) version, the third conductor is located on the left when looking at the composition from above.

T - EXT + S connection D power supply capL - EXT connection

L - EXT connection L - EXT connection

In the INT + S (internal + LHS) version, the third conductor is located on the left when looking at the composition from above.

T connector

Structure composition example - top-down view

Page 267: 3F Filippi  "General catalogue 2016"

264

New

Binario 3FElectrified track for ceiling or suspension installation

The Binario 3F is a mixed 3-phase system with two extra conductors for the management of any signal (eg DALI).The system is certified according to EN 60570 and its installation must be performed by qualified personnel.Three types of fixing:• directly on the surface (using the holes

already provided in binary)• surface mounted using the metal clip• suspended by tension steel cables and

various clamps and brackets without exceeding the maximum loads are planned

1-2-3-4 m length rods are supplied with copper conductors already collected as prescribed by the safety standard.In case it is necessary to shorten the length of the track in the installation phase, after cutting use a special tool (on request) taking care to engagé the 4 conductors (L1-L2-L3-N ) for at least 5 mm, so that the electrical distance and correct creepage.

Dimensions

On request

Black.

Construction characteristics

Mechanical characteristicsElectrified track made from extruded aluminium, Eurostandard Plus® compliant.The wires are enclosed in rigid extruded profiles made of insulating material with high dielectric strength.Length: 1000-2000-3000-4000 mm.Available colors: white (B) and anodized aluminium (GR).

(L1/L2/L3/N/GRD/DA/DA) 16A/440V 2x1A/50V FELV AC (DALI).Copper conductors.

A

H

L

H

Page 268: 3F Filippi  "General catalogue 2016"

265Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

End feed

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Right (view from top)

A4174 New Feeding head DX - B 95x32x38

A4166 New Feeding head DX - GR 95x32x38

Left (view from top)

A4196 New feeding head SX - B 95x32x38

A4190 New Feeding head SX - GR 95x32x38

Power connection: polycarbonate body and copper alloy contacts.Warning: as the track structure is asymmetrical because of the grounding element placed laterally, feeding heads and connecting joints must be chosen accordingly.

Binario 3F

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

White housing

A4151 New Binario 3F - L1000 - B 1000x32x38

A4152 New Binario 3F - L2000 - B 2000x32x38

A4153 New Binario 3F - L3000 - B 3000x32x38

A4154 New Binario 3F - L4000 - B 4000x32x38

Grey housing

A4158 New Binario 3F - L1000 - GR 1000x32x38

A4159 New Binario 3F - L2000 - GR 2000x32x38

A4160 New Binario 3F - L3000 - GR 3000x32x38

A4161 New Binario 3F - L4000 - GR 4000x32x38

Binario 3F

Aluminium extruded track with 6 copper conductors (L1/L2/L3/N/GRD/DA/DA) 16A/440V.

Page 269: 3F Filippi  "General catalogue 2016"

266

End cap

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4180 New End cap - B 32x35x38

A4172 New End cap - GR 32x35x38

Polycarbonate closing cap with locking screw.

Central electrical feeding

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4175 New Central feeding - B 148x32x38

A4167 New Central feeding - GR 148x32x38

Binario 3F

Central power supply with polycarbonate body and copper alloy contacts.

Page 270: 3F Filippi  "General catalogue 2016"

267Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

Flexible connecting element

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4176 New Flexible connecting element - B 265x32x38

A4168 New Flexible connecting element - GR 265x32x38

Linear connecting element with a polycarbonate body and copper alloy contacts.

Linear junction element

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4188 New Linear connecting element - B 25x115x38

A4182 New Linear connecting element - GR 25x115x38

Binario 3F

Page 271: 3F Filippi  "General catalogue 2016"

268

T-junction

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

External (view from top)

A4178 New T-joint - EXT + SX - B 148x90x38

A4198 New T-joint - EXT + DX - B 148x90x38

A4199 New T-joint - INT + SX - B 148x90x38

A4200 New T-joint - INT + DX - B 148x90x38

Internal (view from top)

A4170 New T-joint - EXT + SX - GR 148x90x38

A4192 New T-joint - EXT + DX - GR 148x90x38

A4193 New T-joint - INT + SX - GR 148x90x38

A4194 New T-joint - INT + DX - GR 148x90x38

Warning: as the track structure is asymmetrical because of the grounding element placed laterally, feeding heads and connecting joints must be chosen accordingly.Linear connecting element with a polycarbonate body and copper alloy contacts.

L-junction

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

External (view from top)

A4177 New L-joint - EXT - B 90x90x38

A4169 New L-joint - EXT - GR 90x90x38

Internal (view from top)

A4197 New L-joint - INT - B 90x90x38

A4191 New L-joint - INT - GR 90x90x38

Binario 3F

Warning: as the track structure is asymmetrical because of the grounding element placed laterally, feeding heads and connecting joints must be chosen accordingly.Linear connecting element with a polycarbonate body and copper alloy contacts.

Page 272: 3F Filippi  "General catalogue 2016"

269Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

PVC closing element

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4181 New PVC closing top - L1000 - B 1000x20x10

A4173 New PVC closing top - L1000 - GR 1000x20x10

PVC cover for track closing.

Cross joint

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4179 New Cross joint - B 148x148x38

A4171 New Cross joint - GR 148x148x38

Binario 3F

Fixing accessories

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

A4183 New Steel bracket for ceiling mounting

A4184 New Aluminum bracket for suspension installation

A4185 New Controller for suspension

A4186 New Rose chromed brass ceiling mounting cable

A4187 New Cable suspension with ball - L = 2000

Page 273: 3F Filippi  "General catalogue 2016"

270

New

3F Rocket MLED projector for accent lighting

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B20): 30000 h. (Tp 65°C)Lifetime (L80/B20): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsCylindrical housing in grey RAL 9006 (GR) or white (B) painted aluminium.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.Upper bracket for busbar adaptor, allows angles of inclination from 0° to 90° and 330° rotation on its axis.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Truck adapter, 3-way.

Dimensions

Applications

Environments: commercial, museums, shops.

Source characteristics

• Compact LED module, CCT nominal color temperature 3000 K, color rendering index CRI >90.

• Compact LED modules, /MEAT (version for meat) and /FRESH FOOD (version for fruit / vegetable / bread).

• Color initial tolerance (MacAdam): 3.• Zhaga Book 3 compliant.

On request

• LED module with different powers, CCT nominal color temperature 4000 K, color rendering index CRI >80

• housing in RAL colour• ceiling version• different louvres

H

Ø

Page 274: 3F Filippi  "General catalogue 2016"

271Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Rocket M Meat - Fresh

Code 40916

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

40916 New 3F Rocket M LED B 2000/MEAT 29.6 1572 120x196

40917 New 3F Rocket M LED GR 2000/MEAT 29.6 1572 120x196

E=100%

Meat - Specific source to light up meat and cold cuts.Fresh - Specific source to light up fresh products (fruits, vegetables, bread).

3F Rocket M

Code 40911

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

40911 New 3F Rocket M LED B 3000/930 33 2155 120x196

40912 New 3F Rocket M LED GR 3000/930 33 2155 120x196

3F Rocket M

E=100%

40921 New 3F Rocket M LED B 2000/FRESH FOOD 29.6 1520 120x196

40922 New 3F Rocket M LED GR 2000/FRESH FOOD 29.6 1520 120x196

Page 275: 3F Filippi  "General catalogue 2016"

272

New

3F Rocket LHigh power LED projector for accent lighting

Construction characteristics

Illuminotechnical characteristicsDirect symmetric distribution.Lifetime (L90/B20): 30000 h. (Tp 65°C)Lifetime (L80/B20): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsCylindrical housing in grey RAL 9006 (GR) or white (B) painted aluminium.Parabolic louvre in polished anodised aluminium, anti-glare, non-iridescent.Passive heat dissipator in anodised aluminium, oversized, for optimum thermal management of the LED module.Upper bracket for busbar adaptor, allows angles of inclination from 0° to 30° and 330° rotation on its axis.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Truck adapter, 3-way.

Dimensions

Applications

Environments: commercial, museums, shops.

Source characteristics

• Compact LED module, CCT nominal color temperature 3000 K, color rendering index CRI >90.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 3 compliant.

On request

• LED module with different powers, CCT nominal color temperature 4000 K, color rendering index CRI >80

• housing in RAL colour• ceiling version

H

Ø

Page 276: 3F Filippi  "General catalogue 2016"

273Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Rocket L GR

Code 40984

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

40979 New 3F Rocket L LED GR 4000/930 43 3614 150x200

40984 New 3F Rocket L LED GR 5000/930 50.5 4272 150x200

E=100%

Gray cylindrical body.

3F Rocket L B

Code 40985

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

Ø x H

Electronic

40980 New 3F Rocket L LED B 4000/930 43 3614 150x200

40985 New 3F Rocket L LED B 5000/930 50.5 4272 150x200

3F Rocket L

E=100%

White cylindrical body.

Page 277: 3F Filippi  "General catalogue 2016"
Page 278: 3F Filippi  "General catalogue 2016"

3F info point

Filigare range luminaires are available in two versions:

Filigare - single luminaires3F Fil - luminaires to create continuous lighting channels

Both offer various possibilities of lighting distribution, direct and direct/indirect, wide and medium, symmetrical and asymmetrical, to optimise lighting of the work area.

Filigare Range

Filigare - single luminaires

Available sources:- T5 or T8 Fluorescent

- LED

Standard features:- End caps

- Pre-mounted T5 lamps

Accessories:- Kit to create continuous lines

3F Fil - luminaires to create continuous lighting channels

Available sources:- T5 fluorescent

- LED

Standard features:- Through power supply lines

- Connection kit already fitted on one cap

Accessories:- End caps

Page 279: 3F Filippi  "General catalogue 2016"

276

New

3F Fil LEDLED channel system for high energy efficiency systems and total shielding of the louvre compartment

Construction characteristics

Illuminotechnical characteristicsWide and medium direct symmetric lighting distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in hot-galvanised steel, painted in white polyester.Metal end caps with polycarbonate blend stop bolted on an end cap to form channels, removable blend stop at end of channel or with single luminaire.For cover elements installation, see list of accessories.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.2+2 in-line twin circuit wiring.N07V-K 5-pole cascade powersupply line, (L1-N1+L2-N2+E) of 2.5 mm² section, with snap-in terminal blocks, irreversible, wired to luminaire’s terminal block.

Dimensions

Applications

Environments: commercial, exhibition areas, transit areas, lobbies or waiting rooms, shops, schools.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 2.

On request

• different powers• asymmetric lighting distribution• housing and accessories in RAL colour• wiring: dimmable, emergency• retrofit kit for fluorescent versions• through-wiring up to 11 poles

Accessories

Accessories on page 280.

A

H

L

H

Page 280: 3F Filippi  "General catalogue 2016"

277Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

3F Fil LED RSP Wide

Code 48032

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Through line, 5-pole - Electronic

48030 3F Fil 180 LED 2x30W RSP AMPIO L1550 68 8421 1550x180x85

48032 3F Fil 180 LED 2+2x30W RSP AMPIO L3100 136 16843 3100x180x85

E=100%

Wide distribution.Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.SP diffuser in self-extinguishing V2 transparent polycarbonate, photo-engraved inside, UV stabilised, injection moulded with smooth outside.

3F Fil LED RSP

Code 48019

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Through line, 5-pole - Electronic

48026 3F Fil 180 LED 2x22W RSP L1550 50 6985 1550x180x85

48017 3F Fil 180 LED 2x30W RSP L1550 68 8808 1550x180x85

48028 3F Fil 180 LED 2+2x22W RSP L3100 100 13971 3100x180x85

48019 3F Fil 180 LED 2+2x30W RSP L3100 136 17617 3100x180x85

3F Fil LED

E=100%

Medium distribution.Flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.SP diffuser in self-extinguishing V2 transparent polycarbonate, photo-engraved inside, UV stabilised, injection moulded with smooth outside.

Page 281: 3F Filippi  "General catalogue 2016"

278

3F Fil LED 2US

Code 48066

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Through line, 5-pole - Electronic

48060 New 3F Fil 180 LED 1x30W 2US L1550 34 3435 1550x180x85

48062 New 3F Fil 180 LED 2x30W 2US L1550 68 5980 1550x180x85

48064 New 3F Fil 180 LED 1+1x30W 2US L3100 68 6870 3100x180x85

48066 New 3F Fil 180 LED 2+2x30W 2US L3100 136 11960 3100x180x85

3F Fil LED

L<1000 cd/m² 65°

E>100%

Average luminance <1000 cd/m² for radial angles >65°.2US parabolic louvre in semi-glossy aluminium, anti-glare, with transverse blades closed at the top.Prismatic PMMA diffuser for total shielding of the louvre compartment.Film protective against dust and finger marks, adhesive, attached to louvre.

Page 282: 3F Filippi  "General catalogue 2016"

Syste

ms

Page 283: 3F Filippi  "General catalogue 2016"

280

Coil of stainless steel cable “Ø 1.25 mm”, length 100 m.

Code Item

A0620 Spool with stainless steel cable diam. 1,25mm 100 m

Adjustable suspension for individual luminaries composed of white polycarbonate rosette Ø 110 mm, internal bracket in galvanized steel, stainless steel cable 1.25 mm (length 1 m), quick adjuster, white power cable 5x1.5 mm², H05VV-F (2 m long).

Code Item

A0124 Rose 110 (Adjust. susp.1m unwired)

A0114 Rose 110 (Adjust. susp.1m wired with 5-pole cable)

Adjustable suspension for continuous channel composed of white polycarbonate case, internal bracket in galvanized steel, cables Ø 2 mm in galvanized steel, quick adjusters, maximum load 50 Kg.

Code Item

A0045 Adjustable suspension for channel 1m

A0046 Adjustable suspension for channel 1.5m

A0047 Adjustable suspension for channel 2m

A0762 Adjustable suspension for channel 3m

A0766 Adjustable suspension for channel 4m

A0770 Adjustable suspension for channel 6m

For continuous channel it is always necessary to use the sliding bracket (cod. A0042).On request steel cable, spool of 100 or 500 m.

Concealed sliding bracket for free positioning, in galvanized steel, for mounting to or suspension from the ceiling.It can be adjusted at two heights to position the structure at distances of 16 or 21 mm from the ceiling.It allows mounting also on normally flammable surfaces.

Code Item

A0042 Fil 180 SS (sliding bracket)

Accessories

3F Fil

Pair of end cap cover elements (in white polycarbonate), complete with fixing bolts.

Code Item

A0039 Pair of white end caps Fil 180

Page 284: 3F Filippi  "General catalogue 2016"

281Datasheets, product updates and specifications on our website: www.3f-filippi.com

Syste

ms

Boss with Rose 86 for power-supply connection, in white polycarbonate, white linear power-supply cable, type H05VV-F 5x1.5 mm², length 2 m.

Code Item

A0128 Rose 86 (5-pole wired boss)

Branch with 5-pole line, 50 cm long, to be used if line is powered along the channel or by means of a box for branch joints (cod. 0036 - 0037).

Code Item

A02597 Branch 50cm, plug-socket 5P

Terminal block (plug/socket) with irreversible snap-in double clamp, for power-supply connection at beginning and end of the channel, 5 poles.

Code Item

A02484 5P socket/plug terminal block Beginning/End Channel

Accessories

3F Fil

Clamps in nickel-plated brass suitable for fixing of steel wire (diameter 1.25 mm - 1.5 mm - 2 mm), complete with locking screws.

Code Item

A0622 Clamp 1 hole - 100 pcs

Page 285: 3F Filippi  "General catalogue 2016"
Page 286: 3F Filippi  "General catalogue 2016"

283

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page Product Source Steel Aluminum Stainless steel Polycarbonate

News and updates available on: www.3f-filippi.com > Products > Waterproof and corrosion-proof

284 3F Lem290 New 3F LEM LED •

294 New 3F LEM HO LED •

298 New 3F LEM Sensor LED •

300 New 3F LEM HT LED •

370 Beta 430370 Beta 430 LED LED •

372 Beta 430 Fluo Fluo •

378 3F Cub380 3F Cub LED LED •

386 3F Cub Fluo Fluo •

304 3F Linda306 3F Linda LED LED •

314 New 3F Linda LED Opal LED •

316 3F Linda LED Transparent LED •

318 3F Linda LED Ice LED •

320 3F Linda LED Sensor LED •

322 3F Linda Fluo Fluo •

330 3F Linda Fluo Transparent Fluo •

338 Beta A3F - i3F338 Beta i3F 75-76 LED LED •

342 Beta A3F 90-91 LED LED •

346 Beta Ice LED LED •

349 Beta Kit LED Retrofit LED • •

354 Beta i3F 75-76 Fluo Fluo •

360 Beta A3F 90-91 Fluo Fluo •

366 Beta A3F 92-93 Fluo Fluo •

Waterproof and corrosion-proof

Page 287: 3F Filippi  "General catalogue 2016"

284

The photo shows: 3F LEM 4 LED 200 AMPIO - code 55933

3F LEM is a highly specialised product, designed to satisfy customers who need to light large areas evenly.

We have designed and manufactured it with large injection-moulded shielding which permits different

photometric distributions and lighting modules in aluminium alloy which are able to optimally dissipate

the heat generated by the latest LED sources.

The design of the new 3F LEM is based on simplification and

modularity of design: common platforms and structures create

advantages for the customer in terms of the use, during installation

and even when changing the sources at the end of the product life

cycle.

3F LEM - Light Emitting Modules

A new way of thinking about light

3F LEM

Page 288: 3F Filippi  "General catalogue 2016"

285Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM

Design Patented

Page 289: 3F Filippi  "General catalogue 2016"

286

Page 290: 3F Filippi  "General catalogue 2016"

287Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Mid-Power LEDUse of these LEDs offers improved efficiency (compared to High Power LEDs), less glare and optimised heat distribution (less thermal stress on the sources).

LED photobiological safety: RG0The LEDs used are RG0 class (photobiological risk absent), that is they do not emit any radiation harmful to human organs.

UpgradabilityShielding, sources and power supplies can be replaced at the end of their life cycle, or upgraded to next-generation sources.

Wiring compartment separate from heat dissipatorsThanks to this design, the power supplies are not affected by the heat emitted by the modules. This solution also allows wiring compartments of different lengths to be created.

Air passage3F LEM has been designed to have the best possible air passage in all installation conditions, including ceiling mounted.Aerodynamic analysis has allowed dust deposits on the heat dissipators to be avoided.

3F Lens lenticular lens Available with Wide or Concentrated controlled output (UGR < 22).

3F Filippi is an Emilia-Romagna-based company, and we shares the region’s passion for mechanics and engines in our culture and expertise. It is for precisely this reason that when creating the 3F LEM heatsink module we consulted the foremost authority in the field, the mechanical engineering department at the University of Bologna.Their precious support and expertise led to the creation of the heart of the 3F LEM, the heatsink, or dissipator, module. This is the common denominator across all modules in the product family, and the performance of LEDs depends in large part on their ability to dissipate the heat they generate. Our goal was to create a product which could be installed in high-temperature environments and which would be able to make the sources work correctly.The result is a body made from an innovative pressure die-cast body, which can be installed in environments with temperatures up to 70°C.

Heat dissipation is not the only innovation on 3F LEM:

3F LEMPassion, experience and expertise

Design Patented

Page 291: 3F Filippi  "General catalogue 2016"

288

3F LEMLight which fills space

When we began thinking about 3F LEM, we wanted to place renewed focus on the way large spaces have been illuminated up to now: we perceive the world through our senses, and light is a tool which lets us do so.Objects and other people only exist for us if we can see them, and as a result it is precisely thanks to light that we are able to correctly perceive shapes, colours and the messages we receive from the world every minute of the day.Working in conditions with low or poor-quality lighting has direct and indirect negative effects which influence the way workers perform their work.

For this reason, 3F LEM is equipped with the highest quality LED sources with a CRI>80, but on request can be fitted with sources with CRI>90.It is also possible to obtain light with a colour temperature of 4000K (neutral white), 6500K (cold white) and, on request, 3000K (warm white).With a UGR value of <22, we respect the vision of those who work under 3F LEM lights, as well as respecting health by ensuring all luminaires are RG0 class (photobiological risk absent).

Page 292: 3F Filippi  "General catalogue 2016"

289

DT

DL

DL

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM

WIDE DISTRIBUTION Recommended for industry

Rectangular ground projection

As there is no photometric overlap, the energy used and number of luminairesis optimised.

Allows large longitudinal pitch to obtain uniformity over the aisles and shelving.

Elliptical ground projection

3F LEM fully complies with all applicable illuminotechnical standards and legislation: its lighting distribution comes from careful analysis of BS EN 12464-1 which covers lighting of indoor work environments.We have paid great attention to the requirements of the market and believe that the two different distributions are capable of satisfying even the most demanding customers:

CONCENTRATED DISTRIBUTION Recommended for warehouses with large installation heights

Uniformity

To obtain uniform lighting, the installation pitch is equal to:

DT = 1,5 x hu DL = 1,4 x hu

hu = Effective installation height

Uniformity

To obtain uniform lighting, the installation pitch is equal to:

DL = 1,30 x hu

hu = Effective installation height

Page 293: 3F Filippi  "General catalogue 2016"

290

New

3F LEMHigh bay LED luminaire for hot environments in high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide and elliptically concentrated distribution.Lifetime (L95/B10): 30000 h. (Tp 60°C)Lifetime (L90/B10): 50000 h. (Tp 60°C)Lifetime (L80/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsPassive modular heatsinks in die-casted aluminum, painted in white color.To optimize the thermal management of the LED module, the heatsinks are oversized and provided with self-cleaning of cooling fins.Wiring body in aluminum and steel anchored solidly to the sinks and thermally separated.3F Lens lenses with high luminous efficiency, transparent PMMA, fixed to the LED modules.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Quick connection with plug connector at one end cap and plug supplied.Power unit positioned on a separate compartment by the LED module to ensure optimum temperatures of cabling components, to be inspectable and maintainable.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K or 6500 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Dimensions

Applications

Ambient temperature from -30°C to +55°C.Dry, dusty indoor environments, subject to occasional water splashes.Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with polycarbonate lenses.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

On request

• versions with more than 4 lighting modules• double quick connection with socket/plug• polycarbonate lenses (IK08)• wiring: twin-circuit, emergency• wall fixing brackets (available fixed or

adjustable)• protective casing against the deposit of

dust and bacteria (dedicated to the food industry)

• luminaire 90° rotation bracket (in the horizontal plane)

• tempered glass cover for cleaning• specific version for use in gyms

Accessories

Accessories on page 303.

H

LL

H

L

A

Page 294: 3F Filippi  "General catalogue 2016"

291Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM Concentrated

Code 55938

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55938 New 3F LEM 3 LED 150 CONC 174 24336 562x542x129

55939 New 3F LEM 4 LED 200 CONC 232 32448 757x542x129

E=100%

Distribution concentrated elliptical.Light sources with a color temperature of 4000 K.

3F LEM Wide

Code 55932

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55931 New 3F LEM 2 LED 100 AMPIO 116 15849 470x542x129

55932 New 3F LEM 3 LED 150 AMPIO 174 23774 562x542x129

55933 New 3F LEM 4 LED 200 AMPIO 232 31699 757x542x129

3F LEM

E=100%

Wide distribution with rectangular shape.Light sources with a color temperature of 4000 K.

Page 295: 3F Filippi  "General catalogue 2016"

292

3F LEM Concentrated /865

Code 56010

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56010 New 3F LEM 3 LED 150/865 CONC 174 24579 562x542x129

56011 New 3F LEM 4 LED 200/865 CONC 232 32772 757x542x129

E=100%

Distribution concentrated elliptical.Light sources with a color temperature of 6500 K.

3F LEM Wide /865

Code 56004

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56003 New 3F LEM 2 LED 100/865 AMPIO 116 16007 470x542x129

56004 New 3F LEM 3 LED 150/865 AMPIO 174 24012 562x542x129

56005 New 3F LEM 4 LED 200/865 AMPIO 232 31986 757x542x129

3F LEM

E=100%

Wide distribution with rectangular shape.Light sources with a color temperature of 6500 K.

Page 296: 3F Filippi  "General catalogue 2016"

293Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM DALI Concentrated

Code 55950

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

55950 New 3F LEM 3 LED 150 DALI CONC 174 24336 562x542x129

55951 New 3F LEM 4 LED 200 DALI CONC 232 32448 757x542x129

E=100%

Distribution concentrated elliptical.Light sources with a color temperature of 4000 K.DALI electronic wiring 230V-50/60Hz.

3F LEM DALI Wide

Code 55944

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

55943 New 3F LEM 2 LED 100 DALI AMPIO 116 15849 470x542x129

55944 New 3F LEM 3 LED 150 DALI AMPIO 174 23774 562x542x129

55945 New 3F LEM 4 LED 200 DALI AMPIO 232 31699 757x542x129

3F LEM

E=100%

Wide distribution with rectangular shape.Light sources with a color temperature of 4000 K.DALI electronic wiring 230V-50/60Hz.

Page 297: 3F Filippi  "General catalogue 2016"

294

New

3F LEM HOHigh bay LED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide and elliptically concentrated distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsPassive modular heatsinks in die-casted aluminum, painted in white color.To optimize the thermal management of the LED module, the heatsinks are oversized and provided with self-cleaning of cooling fins.Wiring body in aluminum and steel anchored solidly to the sinks and thermally separated.3F Lens lenses with high luminous efficiency, transparent PMMA, fixed to the LED modules.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.Quick connection with plug connector at one end cap and plug supplied.Power unit positioned on a separate compartment by the LED module to ensure optimum temperatures of cabling components, to be inspectable and maintainable.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Dimensions

Applications

Ambient temperature from -30°C to +45°C.Dry, dusty indoor environments, subject to occasional water splashes.Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with polycarbonate lenses.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

On request

• versions with more than 4 lighting modules• double quick connection with socket/plug• LED modules, CCT nominal color

temperature 6500 K• polycarbonate lenses (IK08)• wiring: twin-circuit, emergency• wall fixing brackets (available fixed or

adjustable)• protective casing against the deposit of

dust and bacteria (dedicated to the food industry)

• luminaire 90° rotation bracket (in the horizontal plane)

• tempered glass cover for cleaning

Accessories

Accessories on page 303.

H

LL

H

L

A

Page 298: 3F Filippi  "General catalogue 2016"

295Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM HO Concentrated

Code 56590

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56589 New 3F LEM 2 HO LED 140 CONC 154 20019 470x542x129

56590 New 3F LEM 3 HO LED 210 CONC 231 30028 562x542x129

E=100%

Distribution concentrated elliptical.

3F LEM HO Wide

Code 56584

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56583 New 3F LEM 2 HO LED 140 AMPIO 154 19557 470x542x129

56584 New 3F LEM 3 HO LED 210 AMPIO 231 29335 562x542x129

56585 New 3F LEM 4 HO LED 280 AMPIO 308 39113 757x542x129

3F LEM HO

E=100%

Wide distribution with rectangular shape.

Page 299: 3F Filippi  "General catalogue 2016"

296

3F LEM HO DALI Concentrated

Code 56602

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

56601 New 3F LEM 2 HO LED 140 DALI CONC 154 20019 470x542x129

56602 New 3F LEM 3 HO LED 210 DALI CONC 231 30028 562x542x129

E=100%

Distribution concentrated elliptical.DALI electronic wiring 230V-50/60Hz.

3F LEM HO DALI Wide

Code 56596

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

56595 New 3F LEM 2 HO LED 140 DALI AMPIO 154 19557 470x542x129

56596 New 3F LEM 3 HO LED 210 DALI AMPIO 231 29335 562x542x129

56597 New 3F LEM 4 HO LED 280 DALI AMPIO 308 39113 757x542x129

3F LEM HO

E=100%

Wide distribution with rectangular shape.DALI electronic wiring 230V-50/60Hz.

Page 300: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 301: 3F Filippi  "General catalogue 2016"

298

New

3F LEM SensorHigh bay LED luminaire with for light sensor for environments in high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide and elliptically concentrated distribution.Lifetime (L95/B10): 30000 h. (Tp 60°C)Lifetime (L90/B10): 50000 h. (Tp 60°C)Lifetime (L80/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsPassive modular heatsinks in die-casted aluminum, painted in white color.To optimize the thermal management of the LED module, the heatsinks are oversized and provided with self-cleaning of cooling fins.Wiring body in aluminum and steel anchored solidly to the sinks and thermally separated.3F Lens lenses with high luminous efficiency, transparent PMMA, fixed to the LED modules.Fixing brackets in stainless steel.

Electrical characteristicsDALI electronic wiring 230V-50/60Hz.Quick connection with plug connector at one end cap and plug supplied.Power unit positioned on a separate compartment by the LED module to ensure optimum temperatures of cabling components, to be inspectable and maintainable.Integrated DALI light sensor on the luminaire, able to maintain a constant level of illumination as a function of the natural light.

Dimensions

Accessories

Accessories on page 303.

Applications

Ambient temperature from -25°C to +50°C.Recommended in environments with strong amount of natural light (or areas with staff present discontinuously).Dry, dusty indoor environments, subject to occasional water splashes.Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with polycarbonate lenses.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• presence function

• manual light intensity adjustment

• versions with more than 4 lighting modules

• double quick connection with socket/plug

• LED modules, CCT nominal color

temperature 6500 K

• polycarbonate lenses (IK08)

• wiring: twin-circuit, emergency

• wall fixing brackets (available fixed or

adjustable)

• protective casing against the deposit of dust

and bacteria (dedicated to the food industry)

• luminaire 90° rotation bracket (in the

horizontal plane)

• tempered glass cover for cleaning

H

A

H

L

Page 302: 3F Filippi  "General catalogue 2016"

299Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f3F LEM Sensor Concentrated

Code 56082

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

56082 New 3F LEM 3 LED 150 DALI Sensor CONC 174 24336 692x542x129

56083 New 3F LEM 4 LED 200 DALI Sensor CONC 232 32448 887x542x129

E=100%

Distribution concentrated elliptical.Integrated DALI light sensor on the luminaire, able to maintain a constant level of illumination as a function of the natural light.

3F LEM Sensor Wide

Code 56076

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

DALI electronic

56076 New 3F LEM 3 LED 150 DALI Sensor AMPIO 174 23774 692x542x129

56077 New 3F LEM 4 LED 200 DALI Sensor AMPIO 232 31699 887x542x129

3F LEM Sensor

E=100%

Wide distribution with rectangular shape.Integrated DALI light sensor on the luminaire, able to maintain a constant level of illumination as a function of the natural light.

Page 303: 3F Filippi  "General catalogue 2016"

300

New

3F LEM HTHigh bay LED luminaire for hot environments in high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide and elliptically concentrated distribution.Lifetime (L95/B10): 30000 h. (Tp 60°C)Lifetime (L90/B10): 50000 h. (Tp 60°C)Lifetime (L80/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsPassive modular heatsinks in die-casted aluminum, painted in white color.To optimize the thermal management of the LED module, the heatsinks are oversized and provided with self-cleaning of cooling fins.Wiring body in aluminum and steel anchored solidly to the sinks and thermally separated.3F Lens lenses with high luminous efficiency, transparent PMMA, fixed to the LED modules.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.Quick connection with plug connector at one end cap and plug supplied.Power unit positioned on a separate compartment by the LED module to ensure optimum temperatures of cabling components, to be inspectable and maintainable.

Dimensions

Accessories

Accessories on page 303.

Applications

Ambient temperature from -30°C to +70°C.Dry, dusty indoor environments, subject to occasional water splashes.Environments: industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with polycarbonate lenses.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• versions with more than 4 lighting modules

• double quick connection with socket/plug• LED modules, CCT nominal color

temperature 6500 K• polycarbonate lenses (IK08)• wiring: twin-circuit, dimmable, emergency• wall fixing brackets (available fixed or

adjustable)• protective casing against the deposit of

dust and bacteria (dedicated to the food industry)

• luminaire 90° rotation bracket (in the horizontal plane)

• tempered glass cover for cleaning

H

LL

H

L

A

Page 304: 3F Filippi  "General catalogue 2016"

301Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F LEM HT Concentrated

Code 56130

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56130 New 3F LEM 3 HT LED 90 CONC 108 15575 562x542x129

56131 New 3F LEM 4 HT LED 120 CONC 144 20767 757x542x129

E=100%

Distribution concentrated elliptical.

3F LEM HT Wide

Code 56124

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56123 New 3F LEM 2 HT LED 60 AMPIO 72 10144 470x542x129

56124 New 3F LEM 3 HT LED 90 AMPIO 108 15215 562x542x129

56125 New 3F LEM 4 HT LED 120 AMPIO 144 20287 757x542x129

3F LEM HT

E=100%

Wide distribution with rectangular shape.

Page 305: 3F Filippi  "General catalogue 2016"

302

3F LEMExamples of design

Design data:

Room dimensions 50x50 metersRoom height 11 metersInstallation height 10 meters

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 meters

Comparison to 400W JM reflector

Current installation400 JM reflector

Like-for-like replacement of light points 3F LEM 2 HO LED 140 AMPIO

Reduction in light points3F LEM 4 HO LED 280 AMPIO

Lighting values 290 lx 309 lx 310 lx

Number of light points 49 49 25

Total power 21.560 W 7.546 W 7.700 W

Difference -65% -64%

Average source lifetime 8.000 hours >50.000 hours >50.000 hours

Current installation250 JM reflector

Like-for-like replacement of light points 3F LEM 2 LED 100 AMPIO

Reduction in light points3F LEM 2 LED 100 AMPIO

Lighting values 174 lx 263 lx 226 lx

Number of light points 49 49 42

Total power 14.210 W 5.684 W 4.872 W

Difference -60% -66%

Average source lifetime 8.000 hours >50.000 hours >50.000 hours

Design data:

Room dimensions 50x50 metersRoom height 8 metersInstallation height 7 meters

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 meters

Comparison to 250W JM reflector

Page 306: 3F Filippi  "General catalogue 2016"

303Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Carabiners to fix the product to a chain.

Code Item

A0653 New Couple of fixing carabiniers for chain installation - 3F LEM

Accessories

3F LEM

Brackets to instal the product on the ceiling or on busbar.

Code Item

A0652 New Couple of brackets for ceiling installation - 3F LEM

Page 307: 3F Filippi  "General catalogue 2016"

304

3F Linda

even cleaner, more compact and solid...

3F Linda Range

3F Linda has become famous for its soft and smooth lines, its patented snug fit snap-lock clips, its compact egg-shaped housing (110 millimetres maximum in the case of ceiling installation with brackets), its internal reinforcement structure and its elastic, shatterproof polycarbonate diffuser.Thanks to its flexibility, it finds applications in residential, commercial and even food industry environments (IFS, HACCP and BRC certification).

3F Linda is available in four different lengths (300, 600, 1200 and 1500 mm) with different power and luminous flux levels, and with both housing widths (100 millimetres and 160 millimetres).

The Fluorescent versions are available with efficient electronic wiring which reduces power consumption and on times.

Thanks to the new diffuser, photo etched on the inside, 3F Linda is now even more economical and high-performance: better diffusion of the light, increased comfort and softer vision.

LED versions 3F Linda LED 3F Linda LED Opale 3F Linda LED Trasparente 3F Linda LED Ice 3F Linda LED Sensor 3F Linda LED Basic 3F Linda HS

Fluorescent versions: 3F Linda Fluo 3F Linda Fluo Trasparente

3F Linda 100 mm

3F Linda 160 mm

Page 308: 3F Filippi  "General catalogue 2016"

305Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

...ecological and efficient.

The new 3F Linda is the best representation of 3F Filippi’s design philosophy: look for the best manufacturing solutions which respect the environment and bring reductions in consumption of materials and energy across the whole product life cycle, via:

Reduction of power consumption and increase in efficiency of our products thanks to the introduction of intelligent electronic wiring, high-efficiency sources and optimisation of the distribution of the luminous flux, thanks also to the possibility of installing flow recuperators.

Limited use of different materials, facilitating assembly, installation and recycling: 3F Linda contains only polycarbonate (housing, diffuser and clips), aluminium or steel (flow recuperator, gear tray and stainless-steel clips) and the copper in the wires (completely removable).Moreover, connection between components are all reversible and use completely recyclable materials, facilitating disassembly and disposal of the product at the end of its lifetime.

Recyclable green packaging, like all of 3F Filippi’s products, in recycled cardboard.

Reduced ecological footprint, with products manufactured with energy from PV solar panels and product handling following a “zero-mile” philosophy.

Installation compatibility with previous versions: the new 3F Linda integrates perfectly in all environments, becoming the perfect solution to update existing installations – thanks to its full compatibility with the previous fluorescent version in terms of its size and accessories.Reuse of these elements means that less energy is used to create new products and accessories for adaption of previous installations.

Quick, safe installation thanks to the fixing brackets which are completely in metal (both the internal and external part), the weight is optimally distributed. The sliding quick connection bracket can also be adjusted to suit the thermal expansion of the luminaire even in environments with a notable temperature range. The set of three fixing brackets is supplied with each luminaire.

3F Linda

Patented

Page 309: 3F Filippi  "General catalogue 2016"

306

3F Linda LEDWatertight luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsControlled symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Ecologic anti-aging injected sealing gasket.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Stainless steel fixing brackets, L=300 mm versions excluded.

Electrical characteristicsElectronic wiring 230V-50/60Hz.EP maintained emergency wiring, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.Not suitable for installation on surfaces subject to important vibrations, exposed to weather conditions, on ropes or poles.For specific applications please contact our technical offices.Wide versionEnvironments with low ceilings, parking lots or wide installation grids.HS versionProduct suitable for installation in food-production/processing environments (HACCP, IFS, BRC Standard).

Source characteristics

• Linear LED modules, CCT nominal color temperature 3000 K, 4000 K or 6500 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• LED sources with different colour temperatures

• wiring: dimmable, class II

Accessories

Accessories on page 334.

L

H

A A

H

Page 310: 3F Filippi  "General catalogue 2016"

307Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda LED

Code 58616

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Colour temperature 4000K - Electronic

58563 New 3F Linda LED 1x6W L660 7.5 1004 660x160x100

58561 3F Linda LED 1x12W L660 14.5 1870 660x100x100

58583 3F Linda LED 1x24W L1270 28 3736 1270x100x100

58605 3F Linda LED 1x30W L1570 34 4672 1570x100x100

58594 3F Linda LED 2x24W L1270 56 7282 1270x160x100

58616 3F Linda LED 2x30W L1570 68 9098 1570x160x100

Colour temperature 3000K - Electronic

58596 New 3F Linda LED 2x24W/830 L1270 56 6918 1270x160x100

58618 New 3F Linda LED 2x30W/830 L1570 68 8644 1570x160x100

Colour temperature 6500K - Electronic

58595 3F Linda LED 2x24W/865 L1270 56 7355 1270x160x100

58617 3F Linda LED 2x30W/865 L1570 68 9199 1570x160x100

Colour temperature 4000K - EP emergency, fuse

58569 New 3F Linda LED 1x6W EP LA L660 7.5 1004 660x160x100

58567 3F Linda LED 1x12W EP LA L660 14.5 1870 660x160x100

58589 3F Linda LED 1x24W EP L1270 28 3736 1270x100x100

58611 3F Linda LED 1x30W EP L1570 34 4672 1570x100x100

58600 3F Linda LED 2x24W EP L1270 56 7282 1270x160x100

58623 3F Linda LED 2x30W EP L1570 68 9098 1570x160x100

Colour temperature 3000K - EP emergency, fuse

58602 New 3F Linda LED 2x24W/830 EP L1270 56 6918 1270x160x100

58625 New 3F Linda LED 2x30W/830 EP L1570 68 8644 1570x160x100

Colour temperature 6500K - EP emergency, fuse

58601 3F Linda LED 2x24W/865 EP L1270 56 7355 1270x160x100

58624 3F Linda LED 2x30W/865 EP L1570 68 9199 1570x160x100

Colour temperature 4000K - ENP emergency, fuse

58713 3F Linda LED 1x24W ENP L1270 530 1270x100x100

58705 3F Linda LED 1x12W ENP LA L660 533 660x160x100

3F Linda LED

E=100%

Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

Page 311: 3F Filippi  "General catalogue 2016"

308

3F Linda LED Compact

Code 5791

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

5791 3F Linda Compatta LED 1x5W 160x300 7.5 477 300x160x100

5790 3F Linda Compatta LED 1x5W 100x300 7.5 481 300x100x100

3F Linda LED

E=100%

Wide longitudinal distribution.Adjustable LED modules.Photobiological safety RG0, risk absent, in compliance with IEC 62471.In compliance with EN 60598-1.Snug fit snap-lock clips for diffuser mounting, in stainless steel.

The Linda LED family is enhanced with this new Compact version, specially designed to be installed in corridors, emergency exits and transit areas: its light guides you along very clearly with its distribution which has been optimised to create light corridors. Thanks to a new type of LED specially designed for this device, consistent energy savings can be achieved and maintenance costs eliminated (average estimated LED source lifetime 80,000 h).

Both Linda Compact LED versions can be wall or ceiling mounted, and offer the possibility to direct the LED source, easily adapting the light strip to any type of installationThe rotating support the LED is fixed to allows the light flow to be oriented up to 45° in both directions, meeting any dedicated lighting requirements and allowing these adjustments to be made with great precision directly on site:

Example of source orientation

Symmetrical luminous flux Example: Asymmetric light flow oriented at 45°

Page 312: 3F Filippi  "General catalogue 2016"

309Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda LED Wide

Code 58661

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58659 3F Linda LED 2x24W AMPIO L1270 56 7259 1270x160x100

58661 3F Linda LED 2x30W AMPIO L1570 68 9072 1570x160x100

E=100%

Wide distribution.Flux recuperator in specular aluminium, high efficiency.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.

3F Linda LED Concentrated

Code 58632

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58630 3F Linda LED 2x24W CONC L1270 56 7134 1270x160x100

58632 3F Linda LED 2x30W CONC L1570 68 8918 1570x160x100

E=100%

Concentrated distribution.Flux recuperator in specular aluminium, high efficiency.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.

3F Linda LED

Page 313: 3F Filippi  "General catalogue 2016"

310

3F Linda LED HS

Code 58730

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58724 3F Linda LED HS 1x30W L1570 34 4672 1570x100x100

58730 3F Linda LED HS 2x30W L1570 68 9098 1570x160x100

E=100%

Body and screen in polycarbonate with additional protective treatment for use in environments with aggressive substances.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.In compliance with EN 60598-1.

3F Linda LED3F Linda LED Basic

Code 58765

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58762 New 3F Linda LED Basic 1x19W L1270 21 2724 1270x100x100

58764 New 3F Linda LED Basic 1x23W L1570 26 3403 1570x100x100

58763 New 3F Linda LED Basic 2x19W L1270 42 5304 1270x100x160

58765 New 3F Linda LED Basic 2x23W L1570 52 6627 1570x100x160

E=100%

Photobiological safety RG0, risk absent, in compliance with IEC 62471.Snug fit snap-lock clips for diffuser mounting, in polycarbonate, tamper-proof screwdriver opening.In compliance with EN 60598-1.

Page 314: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 315: 3F Filippi  "General catalogue 2016"

312

3F Linda LEDExamples of design

Comparison with waterproof Fluorescent 2x58 Starter

Design data:

Room dimensions 30x30 metresRoom height 7 metresInstallation height 5 metres

Number of luminaires: 60 luminaires

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 metres

Current installationWaterproof Fluorescent 2x58W

Like-for-like replacement of light points 3F Linda LED Basic

2x23W L1570

Reduction in light points3F Linda LED 2x30W L1570

Lighting values 300 lx 334 lx 311 lx

Number of light points 60 60 42

Total power8.460 W (starter)

6.600 W (electronic)3.120 W 2.856 W

Difference -63% (starter)

-53% (electronic)-66% (starter)

-53% (electronic)

Average source lifetime10.000 hours (starter)

18.000 hours (electronic)>50.000 hours >50.000 hours

2000 hours annual operation (8 hours per day)

Energy costs51€ (starter)

40€ (electronic)19€

Energy savings per luminaire currently installed

32€* (starter)21€* (electronic)

34€* (starter)23€* (electronic)

3000 hours annual operation (12 hours per day)

Energy costs76€ (starter)

59€ (elettronico)28€

Energy savings per luminaire currently installed

48€* (starter)31€* (electronic)

50€* (starter)33€* (electronic)

*Savings from the drastic reduction in maintenance costs should then be added to this!

Page 316: 3F Filippi  "General catalogue 2016"

313Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Fluorescent Version Consumption (W) Corresponding LED Consumption (W) Savings

T8 2x58W starter 141 3F Linda LED Basic 2x23W L1570 52 63%

HF 109 52%

2x36W starter 90 3F Linda LED Basic 2x19W L1270 42 53%

HF 71 41%

2x18W starter 45 3F Linda LED 1x12W L660 14,5 68%

HF 35 59%

1x58W starter 70 3F Linda LED Basic 1x23W L1570 26 63%

HF 55 53%

1x36W starter 45 3F Linda LED Basic 1x19W L1270 21 53%

HF 36 42%

1x18W starter 27 3F Linda LED 1x6W L660 7,5 72%

HF 19 61%

T5 2x49W 106 3F Linda LED Basic 2x23W L1570 52 51%

2x35W 76 3F Linda LED 1x30W L1570 34 55%

2x28W 60 3F Linda LED 1x24W L1270 28 53%

2x14W 31 3F Linda LED 1x12W L660 14,5 53%

1x80W 86 3F Linda LED 1x30W L1570 34 60%

1x49W 53 3F Linda LED Basic 1x23W L1570 26 51%

1x35W 38 3F Linda LED BAsic 1x19W L1270 21 45%

1x28W 31 3F Linda LED 1x12W L1270 14,5 53%

1x14W 16 3F Linda LED 1x6W L660 7,5 53%

Why choose 3F Linda LED?Never-ending light3F Linda LED is equipped with new 3F LED technology whose sources specially developed for demanding applications guarantee an operating lifetime of over 50,000 hours, at the end of which at least 90% of the LED will still be providing 85% of their initial light output! (50,000h L85/B10).

You won’t believe your wallet! - 3F LED technology allows you to save up to 60% compared to traditional sources. - Existing luminaires can be replaced while maintaining the same light locations and wiring system, but reducing energy consumption.

- Reduced maintenance significantly lowers running costs.

Beauty which doesn’t blind!The new 3F Linda LED photo-etched diffuser cancels out all glare to provide truly enviable lighting uniformity. What’s more, its clean, elegant lines make 3F Linda LED a luminaire which can fit in perfectly with any environment.

Eco-logical3F Linda LED has been created according to the principles of Eco Design, and stands out for: - Manufactured using energy from solar panels and assembled according to our “zero mileage” philosophy - Limited use of different materials, facilitating assembly, installation and recycling - Recyclable green packaging

Significant reduction in maintenance costsLonger life means less maintenance. Less maintenance means greater savings.Less maintenance means fewer problems.Fewer problems means greater peace of mind.

3F Linda LEDComparison table between fluorescent and LED luminaires

Page 317: 3F Filippi  "General catalogue 2016"

314

New

3F Linda LED OpalWaterproof luminaire with high visual comfort for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in glazed self-extinguishing V2 polycarbonate, UV stabilised, injection moulded.Ecologic anti-aging injected sealing gasket.Diffuser in opal self-extinguishing V2 polycarbonate, UV stabilised, injection moulded.Gear-tray reflector unit with reduced width to increase the indirect light, in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in transparent polycarbonate, tamper-proof screwdriver opening.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Entry for power-supply cable in upper central part of body.

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Environments: hospital premises, transit areas, large mirrors, stairwells.Environments where soft diffuse light is required for optimal visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• LED sources with different colour temperatures

• wiring: dimmable, class II, emergency wiring (only 24W and 30W)

Accessories

Accessories on page 334.

L

H

A

H

Page 318: 3F Filippi  "General catalogue 2016"

315Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda LED Opal

Code 58748

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58742 New 3F Linda LED OP 1x12W L660 14.5 1575 660x100x100

58745 New 3F Linda LED OP 1x24W L1270 28 3155 1270x100x100

58748 New 3F Linda LED OP 1x30W L1570 34 3948 1570x100x100

3F Linda LED Opal

E=100%

Snug fit snap-lock clips in transparent polycarbonate.

Page 319: 3F Filippi  "General catalogue 2016"

316

3F Linda LED TransparentWaterproof luminaire for low ceiling environment

Construction characteristics

Illuminotechnical characteristicsControlled symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in transparent self-extinguishing V2 polycarbonate, injection moulded.Ecologic anti-aging injected sealing gasket.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Environments: transit areas, parking lots.Environments where soft diffuse light is required for optimal visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.Not suitable for installation on surfaces subject to important vibrations, exposed to weather conditions, on ropes or poles.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• LED sources with different colour temperatures

• wiring: dimmable, class II

Accessories

Accessories on page 334.

L

H

A A

H

Page 320: 3F Filippi  "General catalogue 2016"

317Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda LED Transparent

Code 58811

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58806 3F Linda LED Trasparente 1x12W L660 14.5 1885 660x100x100

58808 3F Linda LED Trasparente 1x24W L1270 28 3762 1270x100x100

58810 3F Linda LED Trasparente 1x30W L1570 34 4704 1570x100x100

58809 3F Linda LED Trasparente 2x24W L1270 56 7359 1270x160x100

58811 3F Linda LED Trasparente 2x30W L1570 68 9194 1570x160x100

3F Linda LED Transparent

E=100%

Page 321: 3F Filippi  "General catalogue 2016"

318

3F Linda LED IceWatertight luminaire for refrigeration cells down to -30°C

Construction characteristics

Illuminotechnical characteristicsControlled symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Ecologic anti-aging injected sealing gasket.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz, fuse.L-N-E line terminal block with ceramic isolator protection powder-filled fuse, rapid type, 5x20 mm, of suitable capacity, breaking capacity 1500 A.Solid single-core silicone rubber insulated wiring cable with fiberglass braid type UG4T2/2 cross section 0.75 mm².In compliance with EN 60598-1.

Dimensions

Installation

Thanks to new 3F LED technology, the advantages of using 3F Linda LED ICE technology are manifold:• switch-on time less than 5 seconds• unlimited on cycles• lifetime of LED source does not decline

in relation to the number of on cycles

All this results in cost reductions thanks to:• power consumption lower than for

fluorescent versions• no heat transfer from the luminaire to the

cooled environment

Source characteristics

• Linear LED modules UR95, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Accessories

Accessories on page 334.

Applications

Cells with temperature from -30°C to + 40°C with a humidity degree up to 95%.Before installation, we recommend checking that there are no contraindications to the use of and polycarbonate inside the refrigerating room.

L

H

A A

H

Page 322: 3F Filippi  "General catalogue 2016"

319Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f3F Linda LED Ice 2x

Code 58463

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58459 3F Linda LED Ice 2x24W UR95 L1270 56 7282 1270x160x100

58463 3F Linda LED Ice 2x30W UR95 L1570 68 9098 1570x160x100

E=100%

3F Linda LED Ice 1x

Code 58461

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58457 3F Linda LED Ice 1x24W UR95 L1270 28 3736 1270x100x100

58461 3F Linda LED Ice 1x30W UR95 L1570 34 4672 1570x100x100

3F Linda LED Ice

E=100%

Page 323: 3F Filippi  "General catalogue 2016"

320

3F Linda LED SensorWaterproof luminaire with integrated presence sensor for energy-efficient systems

Construction characteristics

Illuminotechnical characteristicsControlled symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Ecologic anti-aging injected sealing gasket.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.Fixing brackets in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.On board DALI light sensor (no cables to be added).Sensor mode: turns on and off depending on light level and presence of persons.CF Corridor function: even with the environment free of people, the luminous flux is maintained at 10%.

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Environments: transit areas, parking lots.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.Not suitable for installation on surfaces subject to strong vibrations, exposed to the elements, on cables or poles.For specific applications please contact our technical offices.

Light Management

For more information on 3F Sensor technology, refer to the specific chapter in the “Light Management” section.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• LED sources with different colour temperatures

• wiring: emergency

Accessories

Accessories on page 334.

L

H

A A

H

Page 324: 3F Filippi  "General catalogue 2016"

321Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f3F Linda LED Sensor CF

Code 58645

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58645 3F Linda LED 1x30W Sensor CF L1570 34 4672 1570x100x100

58649 3F Linda LED 2x30W Sensor CF L1570 68 9098 1570x160x100

E=100%

Integrated presence sensor with Corridor Function mode.Snug fit snap-lock clips in stainless steel.

3F Linda LED Sensor

Code 58642

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

58638 3F Linda LED 1x30W Sensor L1570 34 4672 1570x100x100

58642 3F Linda LED 2x30W Sensor L1570 68 9098 1570x160x100

3F Linda LED Sensor

E=100%

Integrated presence sensor with ON/OFF function.Snug fit snap-lock clips in stainless steel.

Page 325: 3F Filippi  "General catalogue 2016"

322

3F Linda FluoWaterproof luminaire

Construction characteristics

Illuminotechnical characteristicsDiffused symmetric distribution.Using the flux recuperators (see accessories), it is possible to obtain wide to concentrated and asymmetric lighting distribution to meet any installation requirement.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Ecologic anti-aging injected sealing gasket.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Gear-tray reflector unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Stainless steel fixing brackets, 11W versions excluded.

Source characteristics

• 11W compact fluorescent lamps or T5 lamps, mounted (3F Linda T5 multiWatt series excluded), CCT nominal color temperature 4000 K, color rendering index CRI >80.

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.Not suitable for installation on surfaces subject to important vibrations, exposed to weather conditions, on ropes or poles.For specific applications please contact our technical offices.

On request

• fuse accessory for electronic version (on page 472)

• wiring: dimmable, twin-circuit, class II, emergency wiring for T5, emergency inhibition

• luminaires with electronic wiring, in compliance with 94/9/CE (ATEX) standard, group II, category 3D, for Zone 22

• single-lamp luminaire 160 mm wide

Accessories

Accessories on page 334.

L

H

A A

H

Page 326: 3F Filippi  "General catalogue 2016"

323Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda Inox AR

Code 5215

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Starter EEI B1, fuse - Lamps not included

5210 3F Linda Inox 1x18 AR 24 1350 660x100x100

5213 3F Linda Inox 2x18 AR 42.5 2700 660x160x100

5211 3F Linda Inox 1x36 AR 41 3350 1270x100x100

5212 3F Linda Inox 1x58 AR 64 5200 1570x100x100

5214 3F Linda Inox 2x36 AR 82 6700 1270x160x100

5215 3F Linda Inox 2x58 AR 128 10400 1570x160x100

E>70%

Very low loss starter wiring EEI B1, 230V-50Hz, fuse, 0.75 mm² heat resistant wire HT 90°C.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

3F Linda

Code 5205

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Starter EEI B2, fuse - Lamps not included

5200 3F Linda 1x18 26 1350 660x100x100

5203 3F Linda 2x18 43 2700 660x160x100

5201 3F Linda 1x36 43 3350 1270x100x100

5202 3F Linda 1x58 67 5200 1570x100x100

5204 3F Linda 2x36 87 6700 1270x160x100

5205 3F Linda 2x58 134 10400 1570x160x100

Single-lamp version 160 mm wide - Starter EEI B2, fuse - Lamps not included

5206 3F Linda 1x18 LA 26 1350 660x160x100

5207 3F Linda 1x36 LA 43 3350 1270x160x100

5208 3F Linda 1x58 LA 67 5200 1570x160x100

3F Linda Fluo

E>70%

EEI B2 low loss starter wiring, 230V-50Hz, fuse, 0.5 mm² heatresistant wire HT 90°C.Snug fit snap-lock clips in polycarbonate.Fixing brackets in stainless steel.

Page 327: 3F Filippi  "General catalogue 2016"

324

3F Linda Inox Electronic

Code 5225

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5220 3F Linda Inox 1x18 HF 19 1350 660x100x100

5223 3F Linda Inox 2x18 HF 35 2700 660x160x100

5221 3F Linda Inox 1x36 HF 36 3350 1270x100x100

5222 3F Linda Inox 1x58 HF 55 5200 1570x100x100

5224 3F Linda Inox 2x36 HF 71 6700 1270x160x100

5225 3F Linda Inox 2x58 HF 109 10400 1570x160x100

3F Linda Fluo

E>70%

EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

Page 328: 3F Filippi  "General catalogue 2016"

325

3F Linda Fluo

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda Inox T5 MultiWatt

Code 5772

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Electronic MultiWatt EEI A2 - Lamps not included

5768 3F Linda Inox 1x28-54 T5 HF 31-58 2600-4450 1270x100x100

5769 3F Linda Inox 1x35-49-80 T5 HF 38-53-86 3300-4300-6150 1570x100x100

5772 3F Linda Inox 2x35-49 T5 HF 76-106 6600-8600 1570x160x100

E>78%

EEI A2 multiwatt electronic wiring, 230V-50/60Hz, lamp warm start.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

3F Linda Inox T5

Code 5712

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

5700 3F Linda Inox 1x14 T5 HF 16 1200 660x100x100

5707 3F Linda Inox 2x14 T5 HF 31 2400 660x160x100

5702 3F Linda Inox 1x28 T5 HF 31 2600 1270x100x100

5704 3F Linda Inox 1x35 T5 HF 38 3300 1570x100x100

5705 3F Linda Inox 1x49 T5 HF 53 4300 1570x100x100

5709 3F Linda Inox 2x28 T5 HF 60 5200 1270x160x100

5706 3F Linda Inox 1x80 T5 HF 86 6150 1570x100x100

5711 3F Linda Inox 2x35 T5 HF 76 6600 1570x160x100

5712 3F Linda Inox 2x49 T5 HF 106 8600 1570x160x100

Single-lamp version 160 mm wide, CONCENTRATED flow recuperator - EEI A2 electronic wiring - Pre-mounted lamps

5720 3F Linda Inox 1x80 T5 HF LA CONC 86 6150 1570x160x100

E>78%

EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.Concentrated flux recuperator, in specular aluminium with titanium-magnesium surface treatment, non-iridescent, high efficiency, pre-mounted in 1x80 T5 HF code 5720 for environments with considerable height, warehouse aisles or for high localised illumination.

Page 329: 3F Filippi  "General catalogue 2016"

326

3F Linda Compact

Code 5277

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

5275 3F Linda Inox 1x11C HF 12 900 300x100x100

5276 3F Linda Inox 1x11C HF LA 12 900 300x160x100

5277 3F Linda Inox 2x11C HF 23 1800 300x160x100

Starter EEI B2, fuse - Pre-mounted lamps

5260 3F Linda 1x11C 15 900 300x100x100

5261 3F Linda 1x11C LA 15 900 300x160x100

5262 3F Linda 2x11C 30 1800 300x160x100

3F Linda Fluo

E>70%

EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.EEI B2 low loss starter wiring, 230V-50Hz, fuse, 0.5 mm² heatresistant wire HT 90°C.HF versionSnug fit snap-lock clips in stainless steel.Starter versionSnug fit snap-lock clips in polycarbonate.Supplied in a package of:• 12 pieces for 3F Linda 1x11C (housing width 100 mm)• 8 pieces for 3F Linda 1x11C LA - 2x11C (housing width

160 mm)

Page 330: 3F Filippi  "General catalogue 2016"

327Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda Fluo HS

Code 53956

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

53934 3F Linda HS 1x49 T5 LD HF 53 4300 1570x100x100

53956 3F Linda HS 2x49 T5 LD HF 106 8600 1570x160x100

E>78%

EEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.Body and screen in polycarbonate with additional protective treatment for use in environments with aggressive substances.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

3F Linda Fluo

Page 331: 3F Filippi  "General catalogue 2016"

328

3F Linda Fluo Emergency EP

Code 5231

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Snug fit snap-lock clips in stainless steel - EEI A2 electronic wiring, EP emergency, fuse - Lamps not included

5265 3F Linda Inox 1x18 HF EP 19 1350 660x160x100

5254 3F Linda Inox 2x18 HF EP 35 2700 660x160x100

5252 3F Linda Inox 1x36 HF EP 36 3350 1270x100x100

5253 3F Linda Inox 1x58 HF EP 55 5200 1570x100x100

5255 3F Linda Inox 2x36 HF EP 71 6700 1270x160x100

5256 3F Linda Inox 2x58 HF EP 109 10400 1570x160x100

Snug fit snap-lock clips in stainless steel - EEI A2 electronic wiring, EP emergency, fuse - Pre-mounted lamps

5267 3F Linda Inox 1x11C HF LA EP 15 900 300x160x100

5268 3F Linda Inox 2x11C HF EP 30 1800 300x160x100

5741 3F Linda Inox 1x49 T5 HF EP 53 4300 1570x100x100

5764 3F Linda Inox 1x80 T5 HF LA EP CONC 86 6150 1570x160x100

5749 3F Linda Inox 2x49 T5 HF EP 106 8600 1570x160x100

Snug fit snap-lock clips in stainless steel - Starter EEI B1, emergency, fuse - Lamps not included

5246 3F Linda Inox 1x18 AR EP 24 1350 660x160x100

5249 3F Linda Inox 2x18 AR EP 42.5 2700 660x160x100

5247 3F Linda Inox 1x36 AR EP 41 3350 1270x100x100

5248 3F Linda Inox 1x58 AR EP 64 5200 1570x100x100

5250 3F Linda Inox 2x36 AR EP 82 6700 1270x160x100

5251 3F Linda Inox 2x58 AR EP 128 10400 1570x160x100

Snug fit snap-lock clips in polycarbonate - Starter EEI B2, emergency, fuse - Lamps not included

5236 3F Linda 1x18 EP 26 1350 660x160x100

5240 3F Linda 2x18 EP 43 2700 660x160x100

5238 3F Linda 1x36 EP 43 3350 1270x100x100

5231 3F Linda Industria 1x58 EP 67 5200 1570x160x100

5239 3F Linda 1x58 EP 67 5200 1570x100x100

5241 3F Linda 2x36 EP 87 6700 1270x160x100

5242 3F Linda 2x58 EP 134 10400 1570x160x100

3F Linda Fluo

E>81%

Wiring with emergency lighting system (Industrial version, high flux, 15%), 1h duration, 24h recharge.In compliance with EN 60598-2-22.EP version with maintained operation.Versions Industria and CONC are provided with concentrated flux recuperator.Fixing brackets in stainless steel.Emergency luminous flux on page 444.Pictograms for warning signs available (accessories on page 334).

Page 332: 3F Filippi  "General catalogue 2016"

329Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda Fluo Emergency ENP

Code 5230

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

ENP emergency, fuse - Lamps not included

5235 3F Linda 1x18 ENP 297 660x160x100

5245 3F Linda Inox 1x18 ENP 297 660x160x100

5237 3F Linda 1x36 ENP 520 1270x100x100

5230 3F Linda Industria 1x58 ENP 780 1570x160x100

ENP emergency, fuse - Pre-mounted lamps

5257 3F Linda 1x11C ENP 135 300x160x100

5259 3F Linda 1+1x11C ENP 135 300x160x100

3F Linda Fluo

E>81%

Wiring with emergency lighting system (Industrial version, high flux, 15%), 1h duration, 24h recharge.In compliance with EN 60598-2-22.ENP version with not maintained operation.Fixing brackets in stainless steel.Inox - Snug fit snap-lock clips in stainless steel.Emergency luminous flux on page 444.

Page 333: 3F Filippi  "General catalogue 2016"

330

3F Linda Fluo TransparentWatertight luminaire for low-ceiling or cosy environments

Construction characteristics

Illuminotechnical characteristicsDirect-indirect diffused symmetric distribution.UGR19 versionUGR <19.Average luminance <3000 cd/m² for radial angles >65°.

Mechanical characteristicsHousing in transparent self-extinguishing V2 polycarbonate, injection moulded.Ecologic anti-aging injected sealing gasket.Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded with smooth outer surface.Gear-tray reflector unit with reduced width to increase the indirect light, in hot-galvanised steel, painted in white polyester, fixed to the housing by means of steel rapid devices, hinged opening.Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof screwdriver opening.Stainless steel fixing brackets, 11W versions excluded.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with EN 60598-1.EEI B2 low loss starter wiring, 230V-50Hz, fuse.Cascade connection line (available as accessory).

Dimensions

Applications

Dry, dusty indoor environments, subject to occasional water splashes.Environments: transit areas, parking lots.Environments where soft diffuse light is required for optimal visual comfort.Virtually in all environments compatibly with the use of any chemicals which could compromise the use of plastic materials.Not suitable in environments where chlorine fumes, ligroin, hydrocarbon mixtures, mineral oil vapours or fumes of lubricating emulsions to cool down machine tools are present.Neither version suitable for installation on surfaces subject to significant vibrations, exposed to the elements, on cables or poles.UGR19 versionEnvironments with VDTs.Environments where demanding visual tasks are performed and comfortable lighting is required.

Source characteristics

• T5 or 11W compact fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• fuse accessory for electronic version (on page 472)

• wiring: dimmable, emergency• luminaires with electronic wiring, in

compliance with 94/9/CE (ATEX) standard, group II, category 3D, for Zone 22

• 1x-2x 35W T5 versions• 3F Linda Inox UGR19 luminaires with

self-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey

Accessories

Accessories on page 334.

L

H

A A

H

Page 334: 3F Filippi  "General catalogue 2016"

331Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Linda Transparent T8

Code 5355

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5350 3F Linda Trasparente 1x18 HF 19 1350 660x100x100

5351 3F Linda Trasparente 1x36 HF 36 3350 1270x100x100

5352 3F Linda Trasparente 1x58 HF 55 5200 1570x100x100

5354 3F Linda Trasparente 2x36 HF 71 6700 1270x160x100

5355 3F Linda Trasparente 2x58 HF 109 10400 1570x160x100

E>70%

Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

3F Linda Transparent T5

Code 5376

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

5361 3F Linda Trasparente 1x14 T5 HF 16 1200 660x100x100

5363 3F Linda Trasparente 1x28 T5 HF 31 2600 1270x100x100

5365 3F Linda Trasparente 1x49 T5 HF 53 4300 1570x100x100

5374 3F Linda Trasparente 2x28 T5 HF 60 5200 1270x160x100

5376 3F Linda Trasparente 2x49 T5 HF 106 8600 1570x160x100

3F Linda Fluo Transparent

E>79%

Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

Page 335: 3F Filippi  "General catalogue 2016"

332

3F Linda Transparent UGR19

Code 5391

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

5391 3F Linda Trasparente 2x35 T5 LD HF UGR19 76 6600 1570x160x100

L<3000 cd/m² 65°

E>70%

Internal filter (to control luminance) composed by a flux recuperator in aluminum and a PMMA prismatic screen.Snug fit snap-lock clips in stainless steel.Fixing brackets in stainless steel.

3F Linda Transparent Compact

Code 5360

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

5358 3F Linda Trasparente 1x11C HF LA 12 900 300x160x100

5359 3F Linda Trasparente 1x11C HF 12 900 300x100x100

5360 3F Linda Trasparente 2x11C HF 23 1800 300x160x100

Starter EEI B2, fuse - Pre-mounted lamps

5356 3F Linda Trasparente 1x11 C 15 900 300x100x100

5357 3F Linda Trasparente 2x11 C 30 1800 300x160x100

3F Linda Fluo Transparent

E>70%

Snug fit snap-lock clips in stainless steel.

Page 336: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 337: 3F Filippi  "General catalogue 2016"

334

Snug fit snap-lock clips for diffuser mounting, in stainless steel, tamper-proof opening.

Code Item

A0160 Inox clips 3F Linda L660-4pcs

A0161 Inox clips 3F Linda L1270-8pcs

A0162 Inox clips 3F Linda L1570-10pcs

Wire-guard for applications in dry environments, against shocks coming from any directions, galvanized steel rod Ø 5 mm.

Code Item

A0455 Wire guard 180x1330 03F/Linda

A0456 Wire guard 180x1330 03F/Linda

A0457 Wire guard280x1330 03F/Linda/Beta

A0458 Wire guard 280x1630 03F/Linda/Beta

Only for luminaires fixed without hooks.

Pair of stainless steel hooks for suspended installation, with cable clip and nuts and bolts for installation to 3F Linda.

Code Item

A0462 13 GSI (pair of susp. hooks Linda L300)

A0463 13 TRM (pair of susp. hooks Linda L660-1270-1570)

148

Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for wall-mounting, single and twin-lamp luminaires.

Code Item

A0451 15 MBI (w/brack. Linda L300)

A0452 15 FBR (w/brack.+ hooks Linda L660-1270-1570)

45°

Accessories

3F Linda

Pair of brackets and hooks in stainless steel, with nuts and bolts for fixing to 3F Linda, for ceiling or wall-mounting, single and twin-lamp luminaires.Minimum tilt angle = 45°.

Code Item

A0449 15 GZI (w/brack. Linda L300)

A0450 15 RIT (w/brack.+ hooks Linda L660-1270-1570)

Page 338: 3F Filippi  "General catalogue 2016"

335Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Pictograms for warning signs to be applied on emergency luminaire’s diffusers 160 mm wide.Pictogram, 135 mm high, 240 mm long for 11W, 605 mm long for 18W.Pictograms complying with European standards concerning health and safety signals on the workplace.

Code Item

A0468 26 GZM (pictogram P3 Linda L300)

A0469 26 PXN (pictogram P3 Linda L660)

Pictograms for warning signs to be applied on emergency luminaire’s diffusers 160 mm wide.Pictogram, 135 mm high, 240 mm long for 11W, 605 mm long for 18W.Pictograms complying with European standards concerning health and safety signals on the workplace.

Code Item

A0466 26 DVI (pictogram P2 Linda L300)

A0467 26 MVL (pictogram P2 Linda L660)

Pictograms for warning signs to be applied on emergency luminaire’s diffusers 160 mm wide.Pictogram, 135 mm high, 240 mm long for 11W, 605 mm long for 18W.Pictograms complying with European standards concerning health and safety signals on the workplace.

Code Item

A0464 26 CSG (pictogram P1 Linda L300)

A0465 26 MTH (pictogram P1 Linda L660)

Anti-condensation diffuser cable gland.

Code Item

A0187 Anti-condensation cable gland

Recommended for installations in environments with temperature sudden changes or subject to condensation.

Accessories

3F Linda

5-pole cascade connection line, rigid H07V2-U cable, HT 90°C, 1.5 mm², terminal blocks with connection capacity 2x2.5 mm².

Code Item

A0447 3F Linda though line L1570

For all 3F Linda, except models: Transparent, OP and Basic.

Page 339: 3F Filippi  "General catalogue 2016"

336

Parabolic flow recuperator for CONCENTRATED direct distribution, for luminaires 160 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0418 16 EFG (conc. recup.Linda LA 1x18)

A0419 16 QST (conc. recup.Linda LA 1x36)

A0420 16 ATB (conc.recup. Linda LA 1x58)

Parabolic flow recuperator for CONCENTRATED direct distribution, for luminaires 160 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0412 16 DRI (conc. recup.L 2x18)

A0413 16 REC (conc. recup.Linda 2x36)

A0414 16 LZC (conc. recup.Linda 2x58)

A0676 16 CZA (conc. recup.Linda 2x14 T5)

A0677 16 TLS (conc. recup.Linda 2x28 T5)

A0678 16 GHR (conc. recup. Linda 2x35-49 T5)

Parabolic flow recuperator for SUPER-WIDE distribution, for luminaires 160 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0406 16 HZD (super wide. recup. Linda 2x18 )

A0407 16 NBH (super wide. recup. Linda 2x36)

A0408 16 PCL (super wide. recup.Linda 2x58

A0673 16 ALN (s. wide recup. Linda 2x14 T5 )

A0674 16 FGP (s. wide recup. Linda 2x28 T5)

A0675 16 VBC (s. wide recup. Linda 2x35-49 T5 )

Accessories

3F Linda

Parabolic flow recuperator for WIDE direct distribution, for luminaires 160 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0400 16 CLE (wide recup.Linda 2x18)

A0401 16 MRA (wide recup. Linda 2x36)

A0402 16 GPA (wide recup. Linda 2x58)

A0670 16 PSG ( wide recup. Linda 2x14 T5 )

A0671 16 RTA (wide recup. Linda 2x28 T5)

A0672 16 BMT (wide recup. Linda 2x35-49 T5)

Page 340: 3F Filippi  "General catalogue 2016"

337Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Flow recuperator for ASYMMETRIC direct distribution, for luminaires 100 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0436 16 VMR (asym. recup. Linda 1x18)

A0437 16 ZOQ (asym. recup. Linda 1x36)

A0438 16 XGS (asym. recup. Linda 1x58)

A0688 16 KXH (asym. recup. Linda 1x14 T5)

A0689 16 NQE (asym. recup. Linda 1x28 T5)

A0690 16 WAZ ( asym. rec. Linda 1x35-49-80 T5)

Parabolic flow recuperator for ASYMMETRIC direct distribution, for luminaires 160 mm wide.T8 - Flux recuperator in high-reflecting aluminium.

Code Item

A0430 16 FAS (asym. rec. Linda LA 1x18)

A0431 16 GDM (asym. rec. Linda LA 1x36)

A0432 16 BZF ( asym. rec. Linda LA 1x58)

Accessories

3F Linda

Flow recuperator for CONCENTRATED direct distribution, for luminaires 100 mm wide.T8 - Flux recuperator in high-reflecting aluminium.T5 - Flux recuperator in specular aluminium, high-efficiency, with titanium-magnesium surface treatment, non-iridescent.

Code Item

A0424 16 SNN (conc. recup.Linda 1x18)

A0425 16 THO (conc. recup.Linda 1x36)

A0426 16 UIP (conc. recup.Linda 1x58)

A0682 16 ZRB (conc. recup.Linda 1x14 T5)

A0683 16 UCL (conc. recup.Linda 1x28 T5)

A0684 16 EDW (conc. recup.Linda 1x35-49-80 T5)

Page 341: 3F Filippi  "General catalogue 2016"

338

Beta i3F 75-76 LEDLED Luminaire with steel body for energy efficient systems

Construction characteristics

Illuminotechnical characteristicsWide or concentrated direct distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSingle-piece housing in pressed steel, powder-coated in white epoxy-polyester.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.EP maintained emergency wiring, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.Entry for power-supply cable at one end cap, through M20x1,5 self-extinguishing nylon cable gland.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Dimensions

Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Installation

Direct to ceiling, suspended, on busbar or wall-mounted.Mounting hooks and brackets: see accessories.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.

On request

• LED sources with different colour temperatures

• different powers• laminated glass• wiring: dimmable, twin-circuit, class II• tamper-proof closure

Accessories

Accessories on page 369.

Applications

Ambient temperature from -20°C to +35°C.Dry, dusty indoor environments, subject to occasional water splashes.Industrial environments, stores, environments requiring tamper-proof luminaires, such as prisons, thanks to the clips that can be locked by bolts (on request).

i3F 75 i3F 76

A

H

L

A

H

Page 342: 3F Filippi  "General catalogue 2016"

339Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta i3F LED 75 Concentrated

Code 55006

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55006 i3F LED 752x30W CONC L1565 68 9181 1565x235x135

EP emergency, fuse

55017 i3F LED 752x30W EP CONC L1565 68 9181 1565x235x135

E=100%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F LED 75 Wide

Code 55600

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55596 i3F LED 752x12W AMPIO L655 29.5 3647 655x235x140

55598 i3F LED 752x24W AMPIO L1265 56 7296 1265x235x135

55600 i3F LED 752x30W AMPIO L1565 68 9112 1565x235x135

EP emergency, fuse

55607 i3F LED 752x12W EP AMPIO L655 29.5 3647 655x235x140

55609 i3F LED 752x24W EP AMPIO L1265 56 7296 1265x235x135

55611 i3F LED 752x30W EP AMPIO L1565 68 9112 1565x235x135

Beta i3F 75-76 LED

E=100%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 343: 3F Filippi  "General catalogue 2016"

340

Beta i3F LED 76 VT Wide

Code 55072

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55072 i3F LED 762x30W AMPIO VT L1565 68 9221 1565x235x105

EP emergency, fuse

55083 i3F LED 762x30W EP AMPIO VT L1565 68 9221 1565x235x105

E=100%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F LED 76 VS Wide

Code 55138

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55134 i3F LED 762x12W AMPIO VS L655 29.5 3198 655x235x110

55136 i3F LED 762x24W AMPIO VS L1265 56 6408 1265x235x105

55138 i3F LED 762x30W AMPIO VS L1565 68 8006 1565x235x105

EP emergency, fuse

55145 i3F LED 762x12W EP AMPIO VS L655 29.5 3198 655x235x110

55147 i3F LED 762x24W EP AMPIO VS L1265 56 6408 1265x235x105

55149 i3F LED 762x30W EP AMPIO VS L1565 68 8006 1565x235x105

Beta i3F 75-76 LED

E=100%

Wide distribution.VS molded antiglare glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 344: 3F Filippi  "General catalogue 2016"

341Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta i3F LED 76 VT Concentrated

Code 55666

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55666 i3F LED 762x30W CONC VT L1565 68 9386 1565x235x105

EP emergency, fuse

55677 i3F LED 762x30W EP CONC VT L1565 68 9386 1565x235x105

Beta i3F 75-76 LED

E=100%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 345: 3F Filippi  "General catalogue 2016"

342

Beta A3F 90-91 LEDLED luminaire with aluminum body for energy efficient systems

Construction characteristics

Illuminotechnical characteristicsWide or concentrated direct distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSingle-piece housing in pressed aluminium, powder-coated in white epoxy-polyester.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Entry for power-supply cable at one end cap, through M20x1,5 self-extinguishing nylon cable gland.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Dimensions

Any environment except those where aluminium, polycarbonate and glass are unsuitable.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Installation

Suspended, on busbar or wallmounted.Mounting hooks and brackets: see accessories.

On request

• LED sources with different colour temperatures

• laminated glass• fuse accessory (on page 472)• tamper-proof closure

Accessories

Accessories on page 369.

Applications

Ambient temperature from -20°C to +35°C.Dry, dusty indoor environments, subject to occasional water splashes.Industrial environments, stores, environments requiring tamper-proof luminaires, such as prisons, thanks to the clips that can be locked by bolts (on request).

A3F 90 A3F 91

A

H

L

A

H

Page 346: 3F Filippi  "General catalogue 2016"

343Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta A3F LED 90 Concentrated

Code 55799

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55799 A3F LED 902x44W CONC L1565 100 13267 1565x235x135

E=100%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F LED 90 Wide

Code 55205

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55205 A3F LED 902x44W AMPIO L1565 100 13032 1565x235x135

Beta A3F 90-91 LED

E=100%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 347: 3F Filippi  "General catalogue 2016"

344

Beta A3F LED 91 VT Wide

Code 55271

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55271 A3F LED 912x44W AMPIO VT L1565 100 12902 1565x235x105

E=100%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F LED 91 VS Wide

Code 55337

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55337 A3F LED 912x44W AMPIO VS L1565 100 12486 1565x235x105

Beta A3F 90-91 LED

E=100%

Wide distribution.VS molded antiglare glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 348: 3F Filippi  "General catalogue 2016"

345Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta A3F LED 91 VT Concentrated

Code 55865

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

55865 A3F LED 912x44W CONC VT L1565 100 13342 1565x235x105

Beta A3F 90-91 LED

E=100%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 349: 3F Filippi  "General catalogue 2016"

346

Beta Ice LEDLED luminaire, high energy efficiency, for refrigeration cells down to -35°C

Construction characteristics

Illuminotechnical characteristicsWide or concentrated direct distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsSingle-piece housing in pressed aluminium, powder-coated in white epoxy-polyester.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent.Gear-tray unit in hot-galvanised steel, painted in white polyester, fixed to the housing by means of “Ribloc” rapid devices in galvanised steel, hinged opening.Mounting brackets and locking screen clips in stainless steel AISI 304.

Electrical characteristicsElectronic wiring 230V-50/60Hz, fuse.In compliance with EN 60598-1.Entry for power-supply cable at one end cap, through M20x1,5 self-extinguishing nylon cable gland.L-N-E line terminal block with ceramic isolator protection powder-filled fuse, rapid type, 5x20 mm, of suitable capacity, breaking capacity 1500 A.Solid single-core silicone rubber insulated wiring cable with fiberglass braid type UG4T2/2 cross section 0.75 mm².

Dimensions

Applications

12W versionTemperature from -30°C up to +45°C.24W, 30W versionsTemperature from -35°C up to +45°C.60W versionTemperature from -35°C up to +25°C.

Before installation, we recommend checking that there are no contraindications to the use of aluminium and polycarbonate inside the refrigeration cell.

Installation

By means of slotted corner brackets and stainless steel nuts and bolts.Beta Ice LED luminaires can be installed in environments with humidity rate up to 95%.

Source characteristics

• Linear LED modules protected up to RH95 relative humidity, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

Accessories

Accessories on page 369.

A

H

H

L

Page 350: 3F Filippi  "General catalogue 2016"

347Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta Ice LED CONCENTRATO

Code 53867

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

53867 A3F Ice LED 902x30W UR95 CONC L1565 68 9181 1565x235x135

53868 A3F Ice LED 902x60W UR95 CONC L1565 136 16730 1565x235x135

E=100%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta Ice LED Ampio

Code 53862

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

53860 A3F Ice LED 902x12W UR95 AMPIO L655 29.5 3647 655x235x140

53861 A3F Ice LED 902x24W UR95 AMPIO L1265 56 7296 1265x235x135

53862 A3F Ice LED 902x30W UR95 AMPIO L1565 68 9112 1565x235x135

53863 A3F Ice LED 902x60W UR95 AMPIO L1565 136 16435 1565x235x135

Beta Ice LED

E=100%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 351: 3F Filippi  "General catalogue 2016"

348

Page 352: 3F Filippi  "General catalogue 2016"

349

Step 1 Step 2 Step 3 Step 4

FLUO

LED

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

- Energy savings of up to 56% - Protect your investment in existing luminaires: no need to buy new units - No maintenance operations for lamp change - No maintenance operations for starter change

The Fluorescent to LED wiring conversion kit offers the following benefits:

Save on electricity, eliminate maintenance

Fluorescent Versionto replace

LED Retrofit Kitequivalent

Total luminairepower draw

Savings compared to version

Starter EEI A2 electronic wiring*

2x36W T8 2x18W 40 W 56% 44%

2x58W T8 2x30W 68 W 52% 38%

* not to mention the significant savings from reduced maintenance costs!

3F info point

Beta Kit LED Retrofit

Diffuser opening

Removal of existing gear tray unit is quick and does not require tools, just turn the two “Ribloc” devices

by 90°

Kit connectionLED Retrofit via quick

terminal block and refitting the “Ribloc” devices

Diffuser closing

Simple, quick and low-cost conversion:

Page 353: 3F Filippi  "General catalogue 2016"

350

Beta Kit LED RetrofitLED conversion kit for i3F and A3F fluorescent luminaires

Construction characteristics

Illuminotechnical characteristicsWide or concentrated direct distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsGear-tray in hot galvanized steel, painted in white polyester, to be fixed to the body by rapid devices “Ribloc”.For installations prior to 2010, the hinge opening is lost.

Electrical characteristicsElectronic wiring 230V-50/60Hz, constant output power.In compliance with EN 60598-1.

On request

• retrofit Kit for luminaires of length 655mm (1-2x18W) - power 1x36W - 1x58W - for Beta Stainless A3F 92-93 2x58W T8 with gear-tray 2x30W - for Beta Ice 90

• wide flux recuperator to increase luminous flux by 5%

• wiring: dimmable, twin-circuit, different powers• version with asymmetric lighting

distribution

Page 354: 3F Filippi  "General catalogue 2016"

351Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Kit LED Retrofit Beta 2x per schermo in vetro

Code A5117

Code Item Absorbed

power (W)

Output

flux (lm)

Fixture

dimensions

Electronic

A5148 Kit LED i3F 76,A3F 91,A3F 93 - L1265 - 2x18W 40 5503 1265x235x105

A5117 Kit LED i3F 76,A3F 91 - L1565 - 2x30W 68 8668 1565x235x105

A5103 Kit LED i3F 76,A3F 91 - L1565 - 2x30W CONC 68 9386 1565x235x105

E=100%

Flow recuperator in specular aluminium, with superficial titanium-magnesium treatment, non-iridescent (only for CONCENTRATED version).Glass diffuser is NOT included in the kit.

Kit LED Retrofit Beta 2x con schermo in policarbonato

Code A5026

Code Item Absorbed

power (W)

Output

flux (lm)

Fixture

dimensions

Electronic

A5057 Kit LED i3F 75,A3F 90,A3F 92 - L1265 - 2x18W + PC 40 5439 1265x235x135

A5026 Kit LED i3F 75,A3F 90 - L1565 - 2x30W + PC 68 8566 1565x235x135

A5012 Kit LED i3F 75,A3F 90 - L1565 - 2x30W CONC + PC 68 9181 1565x235x135

Beta Kit LED Retrofit

E=100%

Flow recuperator in specular aluminium, with superficial titanium-magnesium treatment, non-iridescent (only for CONCENTRATED version).Diffuser in self-extinguishing V2 polycarbonate, photo-engraved interior, UV stabilised, injection moulded, with smooth outer surface, sealing gasket.

Page 355: 3F Filippi  "General catalogue 2016"

352

Anti-glare moulded glass

Code Item

A5184 Printed glass Beta 2x i3F 76 - L1565

A5185 Printed glass Beta 2x i3F 76 - L1265

Beta Kit LED Retrofit

Anti-glare moulded glass, noncombustible, tempered, locked to the single-piece galvanised steel perimeter frame, sealing gasket.For installations prior to 2010, the hinge opening is lost.

Page 356: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 357: 3F Filippi  "General catalogue 2016"

354

Beta i3F 75-76 FluoLuminaire with steel housing and polycarbonate or glass diffuser

Construction characteristics

Illuminotechnical characteristicsWide or concentrated distribution.

Mechanical characteristicsSingle-piece housing in pressed steel, powder-coated in white epoxy-polyester.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent (18W excluded).

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Entry for power-supply cable at one end cap, through M20x1,5 self-extinguishing nylon cable gland.EP maintained emergency wiring on one single lamp, Ni-Cd battery, inverter, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• different powers with T5 lamps• MultiWatt electronic ballasts for T5 lamps

(except 2x80W)• V0 polycarbonate flat diffuser• laminated glass• fuse accessory (on page 472)

Dimensions

Dry, dusty indoor environments, subject to occasional water splashes.Industrial environments, stores, environments requiring tamper-proof luminaires, such as prisons, thanks to the clips that can be locked by bolts (on request).Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Installation

Direct to ceiling, suspended, on busbar or wall-mounted.Mounting hooks and brackets: see accessories.

• wiring: dimmable, twin-circuit, emergency wiring (2x80W excluded)

• emergency inhibition• 18W version with flux recuperator• 49-80, 36 and 58W versions without flux

recuperators• luminaires with asymmetric or super-wide

flow recuperators• electronic luminaires, class II, in

compliance with 94/9/CE (ATEX) standard, for Zone 22

• tamper-proof closure

Accessories

Accessories on page 369.

Applications

2x80 T5 versions are suitable for environment temperature up to 25°C (for heavier duty uses, require dedicated wirings).

i3F 75 i3F 76

A

H

L

A

H

Page 358: 3F Filippi  "General catalogue 2016"

355Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta i3F 75 T8 Concentrated

Code 5809

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5808 i3F 751x58 HF CONC 55 5200 1565x235x135

5809 i3F 752x58 HF CONC 109 10400 1565x235x135

E=73%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F 75 T8 Wide

Code 5409

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5796 i3F 751x18 HF 19 1350 655x235x140

5797 i3F 752x18 HF 35 2700 655x235x140

5406 i3F 751x36 HF AMPIO 36 3350 1265x235x135

5407 i3F 751x58 HF AMPIO 55 5200 1565x235x135

5408 i3F 752x36 HF AMPIO 71 6700 1265x235x135

5409 i3F 752x58 HF AMPIO 109 10400 1565x235x135

EP emergency, fuse - Lamps not included

5811 i3F 752x36 HF EP AMPIO 71 6700 1265x235x135

5812 i3F 752x58 HF EP AMPIO 109 10400 1565x235x135

Beta i3F 75-76 Fluo

E>75%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 359: 3F Filippi  "General catalogue 2016"

356

Beta i3F 75 T5 Concentrated

Code 56407

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56406 New i3F 751x80 T5 HO HF CONC 86 6150 1565x235x135

56407 New i3F 752x80 T5 HO HF CONC 170 12300 1565x235x135

E=89%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F 75 T5 Wide

Code 56403

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56400 New i3F 751x49 T5 HO HF AMPIO 53 4300 1565x235x135

56401 New i3F 751x80 T5 HO HF AMPIO 86 6150 1565x235x135

56402 New i3F 752x49 T5 HO HF AMPIO 106 8600 1565x235x135

56403 New i3F 752x80 T5 HO HF AMPIO 170 12300 1565x235x135

Beta i3F 75-76 Fluo

E>87%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 360: 3F Filippi  "General catalogue 2016"

357Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta i3F 76 T8 Concentrated

Code 5822

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5821 i3F 761x58 HF CONC 55 5200 1565x235x105

5822 i3F 762x58 HF CONC 109 10400 1565x235x105

E=70%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F 76 T8 Wide

Code 5429

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5817 i3F 761x18 HF 19 1350 655x235x110

5818 i3F 762x18 HF 35 2700 655x235x110

5426 i3F 761x36 HF AMPIO 36 3350 1265x235x105

5427 i3F 761x58 HF AMPIO 55 5200 1565x235x105

5428 i3F 762x36 HF AMPIO 71 6700 1265x235x105

5429 i3F 762x58 HF AMPIO 109 10400 1565x235x105

EP emergency, fuse - Lamps not included

5844 i3F 762x36 HF EP AMPIO 71 6700 1265x235x105

5845 i3F 762x58 HF EP AMPIO 109 10400 1565x235x105

Beta i3F 75-76 Fluo

E>70%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 361: 3F Filippi  "General catalogue 2016"

358

Beta i3F 76 T5 Concentrated

Code 56417

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56416 New i3F 761x80 T5 HO HF CONC 86 6150 1565x235x105

56417 New i3F 762x80 T5 HO HF CONC 170 12300 1565x235x105

E=84%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Beta i3F 76 T5 Wide

Code 56413

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56410 New i3F 761x49 T5 HO HF AMPIO 53 4300 1565x235x105

56411 New i3F 761x80 T5 HO HF AMPIO 86 6150 1565x235x105

56412 New i3F 762x49 T5 HO HF AMPIO 106 8600 1565x235x105

56413 New i3F 762x80 T5 HO HF AMPIO 170 12300 1565x235x105

Beta i3F 75-76 Fluo

E>83%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in galvanized steel, with sealing gasket, hinged opening.Stainless steel screen fixing clips.

Page 362: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 363: 3F Filippi  "General catalogue 2016"

360

Beta A3F 90-91 FluoLuminaire with aluminium housing and polycarbonate or glass diffuser

Construction characteristics

Illuminotechnical characteristicsWide or concentrated distribution.

Mechanical characteristicsSingle-piece housing in pressed aluminium, powder-coated in white epoxy-polyester.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent (18W excluded).

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Entry for power-supply cable at one end cap, through M20x1,5 self-extinguishing nylon cable gland.EP maintained emergency wiring on one single lamp, Ni-Cd battery, inverter, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Source characteristics

• T5 fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• different powers with T5 lamps• laminated glass• V0 polycarbonate flat diffuser• MultiWatt electronic ballasts for T5 lamps

(except 2x80W)• fuse accessory (on page 472)

Dimensions

Applications

2x80 T5 versions are suitable for environment

temperature up to 25°C (for heavier duty uses,

require dedicated wirings).

Dry, dusty indoor environments, subject to

occasional water splashes.

Industrial environments, stores, environments

requiring tamper-proof luminaires, such as

prisons, thanks to the clips that can be locked by

bolts (on request).

Environments in which it is necessary a total

protection against falling fragments (eg

environments with foodstuffs or machines with

moving parts or with extreme temperature

changes), use luminaires with laminated glass.

Tempered glass is not immune to falling fragments

from harmless and caused by shocks or

exceptionally derived from the tempering process.

Installation

Direct to ceiling, suspended, on busbar or

wall-mounted.

Mounting hooks and brackets: see accessories.

• wiring: dimmable, twin-circuit, emergency wiring (2x80W excluded)

• very low loss starter wiring EEI B1, 230V-50Hz, power factor correction, fuse (dedicated for installation in high-temperature environments with peaks up to 45°C - ensures greater thermal balance inside the luminaire)

• emergency inhibition• 18W version with flux recuperator• 49-80, 36 and 58W versions without flux

recuperators• luminaires with asymmetric or super-wide

flow recuperators• electronic luminaires, class II, in compliance

with 94/9/CE (ATEX) standard, for Zone 22• tamper-proof closure

Accessories

Accessories on page 369.

A3F 90 A3F 91

A

H

L

A

H

Page 364: 3F Filippi  "General catalogue 2016"

361Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta A3F 90 T8 Concentrated

Code 5860

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5859 A3F 901x58 HF CONC 55 5200 1565x235x135

5860 A3F 902x58 HF CONC 109 10400 1565x235x135

E=73%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 90 T8 Wide

Code 5449

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5847 A3F 901x18 HF 19 1350 655x235x140

5848 A3F 902x18 HF 35 2700 655x235x140

5446 A3F 901x36 HF AMPIO 36 3350 1265x235x135

5447 A3F 901x58 HF AMPIO 55 5200 1565x235x135

5448 A3F 902x36 HF AMPIO 71 6700 1265x235x135

5449 A3F 902x58 HF AMPIO 109 10400 1565x235x135

EP emergency, fuse - Lamps not included

5866 A3F 902x36 HF EP AMPIO 71 6700 1265x235x135

5867 A3F 902x58 HF EP AMPIO 109 10400 1565x235x135

Beta A3F 90-91 Fluo

E>75%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 365: 3F Filippi  "General catalogue 2016"

362

Beta A3F 90 T5 Concentrated

Code 56427

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56426 New A3F 901x80 T5 HO HF CONC 86 6150 1565x235x135

56427 New A3F 902x80 T5 HO HF CONC 170 12300 1565x235x135

E=89%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 90 T5 Wide

Code 56423

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56420 New A3F 901x49 T5 HO HF AMPIO 53 4300 1565x235x135

56421 New A3F 901x80 T5 HO HF AMPIO 86 6150 1565x235x135

56422 New A3F 902x49 T5 HO HF AMPIO 106 8600 1565x235x135

56423 New A3F 902x80 T5 HO HF AMPIO 170 12300 1565x235x135

Beta A3F 90-91 Fluo

E>87%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 366: 3F Filippi  "General catalogue 2016"

363Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta A3F 91 T8 Concentrated

Code 5873

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5872 A3F 911x58 HF CONC 55 5200 1565x235x105

5873 A3F 912x58 HF CONC 109 10400 1565x235x105

E=70%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 91 T8 Wide

Code 5469

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5868 A3F 911x18 HF 19 1350 655x235x110

5869 A3F 912x18 HF 35 2700 655x235x110

5466 A3F 911x36 HF AMPIO 36 3350 1265x235x105

5467 A3F 911x58 HF AMPIO 55 5200 1565x235x105

5468 A3F 912x36 HF AMPIO 71 6700 1265x235x105

5469 A3F 912x58 HF AMPIO 109 10400 1565x235x105

EP emergency, fuse - Lamps not included

5884 A3F 912x36 HF EP AMPIO 71 6700 1265x235x105

5885 A3F 912x58 HF EP AMPIO 109 10400 1565x235x105

Beta A3F 90-91 Fluo

E>70%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 367: 3F Filippi  "General catalogue 2016"

364

Beta A3F 91 T5 Concentrated

Code 56437

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56436 New A3F 911x80 T5 HO HF CONC 86 6150 1565x235x135

56437 New A3F 912x80 T5 HO HF CONC 170 12300 1565x235x135

E=84%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 91 T5 Wide

Code 56433

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56430 New A3F 911x49 T5 HO HF AMPIO 53 4300 1565x235x105

56431 New A3F 911x80 T5 HO HF AMPIO 86 6150 1565x235x135

56432 New A3F 912x49 T5 HO HF AMPIO 106 8600 1565x235x135

56433 New A3F 912x80 T5 HO HF AMPIO 170 12300 1565x235x135

Beta A3F 90-91 Fluo

E>83%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 368: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 369: 3F Filippi  "General catalogue 2016"

366

Beta A3F 92-93 FluoLuminaire with stainless steel housing and polycarbonate or glass diffuser

Construction characteristics

Illuminotechnical characteristicsWide or concentrated distribution.

Mechanical characteristicsSingle piece pressed stainless steel housing.Oversized flux recuperator in specular aluminium, with titanium-magnesium surface treatment, non-iridescent (18W excluded).

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Entry for power-supply cable at end cap through M20x1,5 nickel-plated brass cable gland.EP maintained emergency wiring on one single lamp, Ni-Cd battery, inverter, 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

occasional water splashes.Environments in which is required a high degree of protection or tamper-proof closure.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Installation

Directly to the ceiling, suspended, on busbar, wall.Mounting hooks and brackets: see accessories.

On request

• laminated glass• V0 polycarbonate flat diffuser• wiring: twin-circuit, emergency, class II• very low loss starter wiring EEI B1,

230V-50Hz, power factor correction, fuse• emergency inhibition• 18W version with flux recuperator• luminaires with asymmetric or super-

wide flow recuperators• tamper-proof closure

Accessories

Accessories on page 369.

Applications

Service areas, prisons, or with aggressive chemicals.Dry, dusty indoor environments, subject to

A3F 92 A3F 93

A

H

L

A

H

Page 370: 3F Filippi  "General catalogue 2016"

367Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta A3F 92 Concentrated

Code 5976

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5975 A3F 921x58 HF CONC 55 5200 1565x235x135

5976 A3F 922x58 HF CONC 109 10400 1565x235x135

E=73%

Concentrated distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 92 Wide

Code 5900

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

5893 A3F 921x18 HF 19 1350 655x235x140

5894 A3F 922x18 HF 35 2700 655x235x140

5897 A3F 921x36 HF AMPIO 36 3350 1265x235x135

5898 A3F 921x58 HF AMPIO 55 5200 1565x235x135

5899 A3F 922x36 HF AMPIO 71 6700 1265x235x135

5900 A3F 922x58 HF AMPIO 109 10400 1565x235x135

EP emergency, fuse - Lamps not included

5902 A3F 922x36 HF EP AMPIO 71 6700 1265x235x135

5903 A3F 922x58 HF EP AMPIO 109 10400 1565x235x135

Beta A3F 92-93 Fluo

E>75%

Wide distribution.Polycarbonate screen etched internally, V2 self-extinguishing, UV stabilized, injection molded, sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 371: 3F Filippi  "General catalogue 2016"

368

Beta A3F 93 Concentrated

Code 5873

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

53904 A3F 931x58 HF CONC 55 5200 1565x235x105

53905 A3F 932x58 HF CONC 109 10400 1565x235x105

E=70%

Concentrated distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Beta A3F 93 Wide

Code 53893

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Lamps not included

53884 A3F 931x18 HF 19 1350 655x235x110

53885 A3F 932x18 HF 35 2700 655x235x110

53890 A3F 931x36 HF AMPIO 36 3350 1265x235x105

53891 A3F 931x58 HF AMPIO 55 5200 1565x235x105

53892 A3F 932x36 HF AMPIO 71 6700 1265x235x105

53893 A3F 932x58 HF AMPIO 109 10400 1565x235x105

EP emergency, fuse - Lamps not included

53898 A3F 932x36 HF EP AMPIO 71 6700 1265x235x105

53899 A3F 932x58 HF EP AMPIO 109 10400 1565x235x105

Beta A3F 92-93 Fluo

E>70%

Wide distribution.VT transparent glass, non-combustible, monobloc perimetrical frame in stainless steel, with sealing gasket, hinged opening.Galvanized steel screen fixing clips.

Page 372: 3F Filippi  "General catalogue 2016"

369Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

fAnti-condensation diffuser cable gland.

Code Item

A0187 Anti-condensation cable gland

Recommended for installations in environments with temperature sudden changes or subject to condensation.

5-pole cascade connection line, stiff cable H07 V2-U, HT 90°C, 1.5 mm², terminal blocks with connection capacity 2x2.5 mm².

Code Item

A0508 20 TKA (casc. conn. line i3F/A3F 36)

A0509 20 ZFE (casc. conn. line i3F/A3F 58)

For A3F versions it is necessary to drill one end cap.

Wire-guard for applications in dry environments, against shocks coming from any directions, galvanized steel rod Ø 5 mm.

Code Item

A0457 Wire guard280x1330 03F/Linda/Beta

A0458 Wire guard 280x1630 03F/Linda/Beta

Pair of steel hooks for suspended installation, with nuts and bolts for luminaire fastening.

Code Item

A0500 13 DH (pair of susp. galvanised steel hooks i3F)

A0501 13 HC (pair of susp. stainless steel hooks A3F)

Accessories

Beta A3F - i3F

Pair of mounting brackets and hooks for wall-mounting, with nuts and bolts for luminaire fastening, everything in stainless steel.

Code Item

A0503 15 CD (pair of bracket and hooks A3F)

Page 373: 3F Filippi  "General catalogue 2016"

370

Beta 430 LEDIndustrial high-efficiency LED luminaire

Construction characteristics

Illuminotechnical characteristicsWide symmetrical or hyperconcentrated distribution.Photobiological safety RG0 unlimited, risk absent, in compliance with IEC 62471, IEC/TR 62778.

Mechanical characteristicsHousing in steel, powder-coated in white epoxy-polyester.Quick connection in polycarbonate M20x1.5 cable gland for access to the terminal block.

Electrical characteristicsElectronic wiring 230V-50/60Hz.In compliance with EN 60598-1.Quick connection.Twin-circuit.

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.• Zhaga Book 7 compliant.

Dimensions

extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Notes

HST glassHST glass is composed of a tempered glass sheet which has undergone a thermal stabilisation process (Heat Soak Test) which reduces the risk of spontaneous breakage caused by nickel-sulfide inclusions inside the glass.It is not immune from harmless falling fragments, caused byshocks or, exceptionally, derived from the tempering process.It is the user’s responsibility to identify the most suitable type of diffuser for the application type.

On request

• anti-glare moulded VS glass• laminated glass• diffuser in prismatic PMMA or

polycarbonate, either transparent or prismatic

• wiring: dimmable, single-circuit

Accessories

Accessories on page 376.

Applications

Ambient temperature from -20°C to +35°C.Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with

A

H

L

Page 374: 3F Filippi  "General catalogue 2016"

371Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta 430 LED IperConcentrated

Code 53490

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

53490 Beta Iperconc LED 4x30W CR VT IP64 L1551 136 17924 1551x430x159

53493 Beta Iperconc LED 4x30W CR SL IP64 L1551 136 17924 1551x430x159

E=100%

Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Single-piece perimeter frame in galvanized steel, sealing gasket, hinged opening by means of clips in galvanized steel.Safety system to prevent diffuser from falling.Transparent glass HST tempered, non-combustible.SL transparent PMMA flat diffuser.

Beta 430 LED

Code 53445

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

53438 i3F LED 764x50W CR AMPIO VT L1251 209 28162 1251x430x159

53452 i3F LED 764x50W CR AMPIO SL L1251 209 28162 1251x430x159

53445 i3F LED 764x63W CR AMPIO VT L1551 261 33390 1551x430x159

53459 i3F LED 764x63W CR AMPIO SL L1551 261 33390 1551x430x159

Beta 430 LED

E=100%

Lifetime (L90/B50): 30000 h. (Tp 60°C)Lifetime (L80/B50): 50000 h. (Tp 60°C)Lifetime (L70/B50): 80000 h. (Tp 60°C)Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Single-piece perimeter frame in galvanized steel, sealing gasket, hinged opening by means of clips in galvanized steel.Safety system to prevent diffuser from falling.Transparent glass HST tempered, non-combustible.SL transparent PMMA flat diffuser.

Page 375: 3F Filippi  "General catalogue 2016"

372

Beta 430 FluoIndustrial high-efficiency luminaire

Construction characteristics

Illuminotechnical characteristicsWide symmetrical, concentrated or hyperconcentrated distribution.

Mechanical characteristicsHousing in steel, powder-coated in white epoxy-polyester.Quick connection in polycarbonate M20x1.5 cable gland for access to the terminal block.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, twin-lamp ballasts with lamp warm start.Quick connection.Twin circuit for version with 4 sources (lamps 1-4 and 2-3) and 6 sources (lamps 1-2-5-6 and 3-4).

Source characteristics

• T5, T8 or compact fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• fuse accessory (on page 472)• anti-glare moulded VS glass• laminated glass• self-extinguishing polycarbonate diffuser• wiring: dimmable, high flux emergency• luminaires without fast connection, Class

II, in compliance with 94/9/CE (ATEX)

Dimensions

Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Notes

HST glassHST glass is composed of a tempered glass sheet which has undergone a thermal stabilisation process (Heat Soak Test) which reduces the risk of spontaneous breakage caused by nickel-sulfide inclusions inside the glass.It is not immune from harmless falling fragments, caused byshocks or, exceptionally, derived from the tempering process.It is the user’s responsibility to identify the most suitable type of diffuser for the application type.

standard, group II, category 3D, Zone 22• open version with cathode covers in

steel, for luminaire to prevent lamp from falling

Accessories

Accessories on page 376.

Applications

Ambient temperature from -15°C to +40°C.Dry, dusty indoor environments, subject to occasional water splashes.Environments: commercial, exhibition areas, industrial, sports, fairs, stores, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.

A

H

L

Page 376: 3F Filippi  "General catalogue 2016"

373Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta 430 Fluo Concentrated IP43

Code 56461

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56461 New i3F 714x80 T5 HO LD HF CR CONC IP43 340 24600 1551x430x151

56488 New i3F 716x49 T5 HO LD HF CR CONC IP43 318 25800 1551x430x151

56489 New i3F 716x54 T5 HO LD HF CR CONC IP43 342 26700 1251x430x151

EEI A2 electronic wiring - Lamps not included

57012 i3F 714x58 LD HF CR CONC IP43 218 20800 1551x430x151

E=100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.

Beta 430 Fluo Wide IP43

Code 56459

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56458 New i3F 714x54 T5 HO LD HF CR AMPIO IP43 228 17800 1251x430x151

56459 New i3F 714x80 T5 HO LD HF CR AMPIO IP43 340 24600 1551x430x151

56484 New i3F 716x49 T5 HO LD HF CR AMPIO IP43 318 25800 1551x430x151

56485 New i3F 716x54 T5 HO LD HF CR AMPIO IP43 342 26700 1251x430x151

EEI A2 electronic wiring - Lamps not included

57004 i3F 714x58 LD HF CR AMPIO IP43 218 20800 1551x430x151

Beta 430 Fluo

E>100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.

Page 377: 3F Filippi  "General catalogue 2016"

374

Beta 430 Fluo Wide IP64

Code 56451

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56450 New i3F 764x54 T5 HO LD HF CR AMPIO IP64 228 17800 1251x430x159

56466 New i3F 764x54 T5 HO LD HF CR AMPIO SL IP64 228 17800 1251x430x159

56451 New i3F 764x80 T5 HO LD HF CR AMPIO IP64 340 24600 1551x430x159

56467 New i3F 764x80 T5 HO LD HF CR AMPIO SL IP64 340 24600 1551x430x159

56474 New i3F 766x49 T5 HO LD HF CR AMPIO IP64 318 25800 1551x430x159

56494 New i3F 766x49 T5 HO LD HF CR AMPIO SL IP64 318 25800 1551x430x159

56475 New i3F 766x54 T5 HO LD HF CR AMPIO IP64 342 26700 1251x430x159

56495 New i3F 766x54 T5 HO LD HF CR AMPIO SL IP64 342 26700 1251x430x159

57390 i3F 764x55 C AMPIO IP64 236 17200 654x430x159

EEI A2 electronic wiring - Lamps not included

57049 i3F 764x58 LD HF CR AMPIO SL IP64 218 20800 1551x430x159

57094 i3F 764x58 LD HF CR AMPIO IP64 218 20800 1551x430x159

E=91%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Single-piece perimeter frame in galvanized steel, sealing gasket, hinged opening by means of clips in galvanized steel.Safety system to prevent diffuser from falling.Transparent glass HST tempered, non-combustible.SL transparent PMMA flat diffuser.

Beta 430 Fluo IperConcentrated IP43

Code 56515

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56515 New Beta Iperconc 2x80 T5 HO LD HF CR IP43 170 12300 1551x430x151

56517 New Beta Iperconc 2+2x54 T5 HO LD HF CR IP43 228 17800 1251x430x151

56516 New Beta Iperconc 2+2x80 T5 HO LD HF CR IP43 340 24600 1551x430x151

Beta 430 Fluo

E=100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.

Page 378: 3F Filippi  "General catalogue 2016"

375Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Beta 430 Fluo IperConcentrated IP64

Code 56510

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56510 New Beta Iperconc 2x80 T5 HO LD HF CR VT IP64 170 12300 1551x430x159

56520 New Beta Iperconc 2x80 T5 HO LD HF CR SL IP64 170 12300 1551x430x151

56512 New Beta Iperc. 2+2x54T5 HO LD HF CR VT IP64 228 17800 1251x430x159

56522 New Beta Iperc. 2+2x54T5 HO LD HF CR SL IP64 228 17800 1251x430x151

56511 New Beta Iperc. 2+2x80T5 HO LD HF CR VT IP64 340 24600 1551x430x159

56521 New Beta Iperc. 2+2x80T5 HO LD HF CR SL IP64 340 24600 1551x430x151

E>93%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Single-piece perimeter frame in galvanized steel, sealing gasket, hinged opening by means of clips in galvanized steel.Safety system to prevent diffuser from falling.Transparent glass HST tempered, non-combustible.SL transparent PMMA flat diffuser.

Beta 430 Fluo Concentrated IP64

Code 56453

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56453 New i3F 764x80 T5 HO LD HF CR CONC IP64 340 24600 1551x430x159

56469 New i3F 764x80 T5 HO LD HF CR CONC SL IP64 340 24600 1551x430x159

56478 New i3F 766x49 T5 HO LD HF CR CONC IP64 318 25800 1551x430x159

56498 New i3F 766x49 T5 HO LD HF CR CONC SL IP64 318 25800 1551x430x159

56479 New i3F 766x54 T5 HO LD HF CR CONC IP64 342 26700 1251x430x159

56499 New i3F 766x54 T5 HO LD HF CR CONC SL IP64 342 26700 1251x430x159

EEI A2 electronic wiring - Lamps not included

57055 i3F 764x58 LD HF CR CONC SL IP64 218 20800 1551x430x159

57102 i3F 764x58 LD HF CR CONC IP64 218 20800 1551x430x159

Beta 430 Fluo

E=90%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Single-piece perimeter frame in galvanized steel, sealing gasket, hinged opening by means of clips in galvanized steel.Safety system to prevent diffuser from falling.Transparent glass HST tempered, non-combustible.SL transparent PMMA flat diffuser.

Page 379: 3F Filippi  "General catalogue 2016"

376

Accessories

Beta 430

Wire-guard for applications in dry environments, against shocks coming from any directions, in galvanized steel rod Ø 5 mm; only for luminaires fixed with no hooks.

Code Item

A0528 Wireguard Beta 4x54-6x54

A0529 Wireguard Beta 4x58/80-6x49

Page 380: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 381: 3F Filippi  "General catalogue 2016"

378

- Easy and quick installation - Energy savings - Light quality - High efficiency - High dependability - Economical Management

3F Cub LED and 3F Cub Fluorescentare luminairesfor industry, sales areas and large spaces based on dedicatedtechnologies allowinglong lamp life andlow maintenance, even in particularly tough conditions.

Thanks to Quick Connection (standard on all versions), minimal time is required to install the luminaires: as it is no longer necessary to open them, the terminal block can be extracted quickly and simply from the upper opening for connection.

3F Cub LED and FluorescentLighter. Brighter. More energy savings.

With quick connection.

The best Cub ever.

dust flows upwards

thermal shielding effect

Patented

Page 382: 3F Filippi  "General catalogue 2016"

379Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Light quality

- Turning on and turning back on always immediate. - Excellent colour rendering Ra> 80 (in line with European standard EN 12464 on workplace lighting).

- Reduced glare. - No strobe effect. - Wide tolerance on mains voltage (± 10%). - No UV emissions. - Brightness of light - Adjustable luminous flux and/or lamp automatic switch-off thanks to sensors and photocells.

- Excellent colour rendering Ra> 80 (in line with European standard EN 12464 on workplace lighting).

- Reduced glare. - No strobe effect. - Wide tolerance on mains voltage (± 10%). - Very low UV emissions. - High flux emergency wiring. - Adjustable luminous flux and/or lamp automatic switch-off thanks to sensors and photocells.

High efficiency

- Efficiency greater than 102 lm/W thanks to the oversized aluminium flow recuperator with titanium-magnesium treatment, with linear LED modules.

- Luminous efficiency over 90% thanks to oversized flow recuperator in specular aluminium with titanium-magnesium treatment, with 55W compact electronic lamps.

Energy savings

- High energy efficiency electronic ballasts. - Fast return on investment - Electronic ballasts in EI A1 or EEI A2 efficiency class.

- 3F Cub complies with 2000/55/EC European Directive on energy efficiency requirements of ballasts for fluorescent lamps.

High dependability

- 3F Cub Led is suitable for ambient temperatures up to +45°C thanks to its oversized aluminium body which guarantees components optimum thermal balance.

- LED modules compliant with Zhaga specifications for changing LED strips.

- Photobiological risk absent (IEC/EN 62471:2010).

- 3F Cub Fluorescent is IMQ certified for ambient temperatures up to +40°C for the 4x55 version, up to +30°C for the 6x55 version, thanks to the oversized aluminium housing which guarantees thermal equilibrium for the electrical components. The fluorescent IP43 versions also have no dust deposits on the lamps and internal flow recuperators thanks to the thermal shielding effect created by the luminaire itself.

Economical Management

- Very high source lifetime, 50,000 hrs. - Standard twin-circuit wiring. - Less decrease of the source’s light flow over time thanks to heat dissipation.

- Increased safety: the electronic wiring ensures automatic disconnection of the power supply in case of defective LED module.

- Highly efficient luminaire: over 102 lm/W. - Mercury-free source - Less heat lost to the environment - No non-scheduled maintenance operations: faulty or burned-out strips do not compromise work.

- Easy and quick installation and power-supply connection also thanks to quick connection.

- 3F Cub LED has glass or diffuser for total protection, for environments with large quantities of dust to maintain lighting efficiency over time and minimise cleaning of reflecting surfaces.

- Very long lamp average life.

- Standard twin-circuit wiring. - Lower decrease of luminous flux of lamps over time. - Increased safety: the electronic wiring ensures automatic disconnection of the power supply in case of defective lamp.

- Highly efficient lamps: over 87 lm/W. - No non-scheduled maintenance operations: faulty or burned-out lamps do not compromise work.

- Easy and quick installation and power-supply connection also thanks to quick connection.

- Fume-repellent flow recuperators allowing installation in industrial environments, even of versions without diffuser.

- For environments with significant amounts of dust, versions with glass or diffuser for total protection, to maintain lighting efficiency over time and minimise cleaning of reflecting surfaces.

3F Cub LED 3F Cub Fluorescent

3F Cub LED e Fluorescente

Page 383: 3F Filippi  "General catalogue 2016"

380

3F Cub LEDLED luminaire for high energy efficiency systems

Construction characteristics

Illuminotechnical characteristicsWide symmetric distribution.Lifetime (L90/B10): 30000 h. (Tp 60°C)Lifetime (L85/B10): 50000 h. (Tp 60°C)Lifetime (L75/B10): 80000 h. (Tp 60°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsHousing with double casing in pressed aluminium, powder-coated in white epoxy-polyester, hinged opening.Quick connection in polycarbonate M20x1.5 cable gland for access to the terminal block.Ecologic anti-aging injected sealing gaskets.Stainless steel clips.Total flow recuperator in specular aluminium, with superficial titanium-magnesium treatment, non-iridescent.VT transparent or VS moulded anti glare glass, noncombustible, tempered.SP transparent PMMA flat diffuser, multilenticular, anti-glare, prismatic exterior.Fixing bracket.

Electrical characteristicsElectronic wiring 230V-50/60Hz.DALI electronic wiring 230V-50/60Hz.Quick connection.Twin-circuit.

Dimensions

Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Light Management

For more information on CLO technology, refer to the specific chapter in the “Light Management” section.The DALI products of this family can be controlled manually with the technology “3F Easy” or even automatically and manually using the “3F Smart Dimming” technology (see “Light Management” chapter).

Source characteristics

• Linear LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• concentrated distribution• laminated glass• wiring: single-circuit, emergency• LED modules, CCT nominal color

temperature 6500 K

Accessories

Accessories on page 389.

Applications

100W versionAmbient temperature from -20°C to +45°C.150W versionAmbient temperature from -20°C to +40°C.

A = L

H

Page 384: 3F Filippi  "General catalogue 2016"

381Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Cub LED SP

Code 56347

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56344 3F CUB LED 100W CR SP 110 13408 680x680x187

56347 3F CUB LED 150W CR SP 163 19691 680x680x187

DALI electronic

56346 New 3F CUB LED 100W DALI CR SP 110 13408 680x680x187

56349 New 3F CUB LED 150W DALI CR SP 163 19691 680x680x187

E=100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.SP transparent methacrylate diffuser, prismatic outside, antiglare.

3F Cub LED VT

Code 56333

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56330 3F CUB LED 100W CR VT 110 14222 680x680x187

56333 3F CUB LED 150W CR VT 163 20994 680x680x187

DALI electronic

56332 New 3F CUB LED 100W DALI CR VT 110 14222 680x680x187

56335 New 3F CUB LED 150W DALI CR VT 163 20994 680x680x187

3F Cub LED

E=100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Transparent glass VT tempered, non-combustible.

Page 385: 3F Filippi  "General catalogue 2016"

382

3F Cub LED VS

Code 56340

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

56337 3F CUB LED 100W CR VS 110 13083 680x680x187

56340 3F CUB LED 150W CR VS 163 19282 680x680x187

DALI electronic

56339 New 3F CUB LED 100W DALI CR VS 110 13083 680x680x187

56342 New 3F CUB LED 150W DALI CR VS 163 19282 680x680x187

3F Cub LED

E=100%

Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.VS moulded glass, anti-glare, tempered, non-combustible.

Page 386: 3F Filippi  "General catalogue 2016"

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Page 387: 3F Filippi  "General catalogue 2016"

384

3F Cub LEDExamples of design

Comparison to 400W JM reflector

Design data:

Room dimensions 50x50 metersRoom height 9 metersInstallation height 8 meters

Number of luminaires: 56 luminaires (6.3x7.1 metre grid)

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 meters

400W JM reflector 3F Cub LED 150W CR VT Difference

Lighting values 345 lux 364 lux + 6%

Luminaire power 440 W 162 W - 63%

Circuit type Single circuit (100%) Twin circuit (50% - 100%)

Regulation of luminous flux and power?

No Yes, depending on requirements

Source life 8.000 hours 50.000 hours +42.000 hours

3F Cub R90 4x55 IP43 3F Cub LED 150W CR VT Difference

Lighting values 334 lux 364 lux + 9%

Luminaire power 240 W 162 W - 33%

Circuit type Twin circuit (50% - 100%) Twin circuit (50% - 100%)

Regulation of luminous flux and power?

Yes, depending on requirements Yes, depending on requirements

Source life 15.000 hours 50.000 hours +35.000 hours

Comparison to 3F Cub R90 4x55 IP43

Design data:

Room dimensions 50x50 metersRoom height 9 metersInstallation height 8 meters

Number of luminaires: 56 luminaires (6.3x7.1 metre grid)

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 meters

Page 388: 3F Filippi  "General catalogue 2016"

385Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Cub LED

3F Cub 4x55 CR VT IP64 3F Cub LED 100W CR VT Difference

Lighting values 334 lux 366 lux + 10%

Luminaire power 240 W 110 W - 54%

Circuit type Twin circuit (50% - 100%) Twin circuit (50% - 100%)

Regulation of luminous flux and power?

Yes, depending on requirements Yes, depending on requirements

Source life 15.000 hours 50.000 hours +35.000 hours

Comparison to 3F Cub 4x55 VT IP64

Design data:

Room dimensions 30x30 metersRoom height 7 metersInstallation height 6 meters

Number of luminaires: 30 luminaires (6x5 metre grid)

Like-for-like replacement of light points

Reflection ceiling 30% walls 30% floor 10%

Work surface height 0.85 meters

Why choose 3F Cub LED?

Never-ending light3F Cub LED is equipped with new 3F LED technology whose sources specially developed for demanding applications guarantee an operating lifetime of over 50,000 hours, at the end of which at least 50% of the LED will still be providing 80% of their initial light output!

You won’t believe your wallet! - 3F LED technology allows you to save up to 60% compared to traditional sources. - Existing luminaires can be replaced while maintaining the same light locations and wiring system, but reducing energy consumption.

- Reduced maintenance significantly lowers running costs.

Beauty which doesn’t blind!The 3F Cub LED diffuser attenuates or cancels out all glare and creates a truly enviable lighting uniformity (in relation to the installation height). What’s more, its clean, elegant lines make 3F Cub LED a luminaire which can fit in perfectly with any environment.

Eco-logical3F Cub LED has been created according to the principles of Eco Design, and stands out for: - Manufactured using energy from solar panels and assembled according to our “zero mileage” philosophy - Limited use of different materials, facilitating assembly, installation and recycling - Recyclable green packaging

Significant reduction in maintenance costsLonger life means less maintenance. Less maintenance means greater savings.Less maintenance means fewer problems.Fewer problems means greater peace of mind.

Page 389: 3F Filippi  "General catalogue 2016"

386

3F Cub FluoFast connection and lamp avoid

Construction characteristics

Illuminotechnical characteristicsWide or concentrated symmetric lighting distribution.

Mechanical characteristicsHousing with double casing in pressed aluminium, powder-coated in white epoxy-polyester, hinged opening.Quick connection in polycarbonate M20x1.5 cable gland for access to the terminal block.Ecologic anti-aging injected sealing gaskets.Stainless steel clips.Total flow recuperator in specular aluminium, with superficial titanium-magnesium treatment, non-iridescent.VT transparent glass, non-combustible, tempered.SL transparent PMMA flat diffuser.Fixing bracket.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, twin-lamp ballasts with lamp warm start.Fast connection and lamp avoid.Twin-circuit.EP maintained emergency wiring, on one single lamp, (entry for power-supply cable separated from fast connection), high flux (15%), 1hr duration with 24hrs recharge, fuse.In compliance with EN 60598-2-22.

Dimensions

Applications

Ambient temperature from -15°C to +40°C.Dry, dusty indoor environments, subject to occasional water splashes.Environments: commercial, industrial, sports, stores, sports halls, gymnasiums.Environments in which it is necessary a total protection against falling fragments (eg environments with foodstuffs or machines with moving parts or with extreme temperature changes), use luminaires with laminated glass.Tempered glass is not immune to falling fragments from harmless and caused by shocks or exceptionally derived from the tempering process.

Source characteristics

• Compact fluorescent lamps, mounted, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• moulded anti-glare glass• laminated glass• fuse accessory (on page 472)• wiring: dimmable• emergency inhibition• IP64 luminaires with no fast connection,

Class II, in compliance with 94/9/CE (ATEX) standard, group II, category 3D, for Zone 22

• double quick connection

Accessories

Accessories on page 389.

A = L

H

Page 390: 3F Filippi  "General catalogue 2016"

387Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

3F Cub IP64

Code 56210

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

GLASS - EEI A2 electronic wiring - Pre-mounted lamps

56210 3F Cub 4x55 CR VT IP64 236 17200 680x680x187

GLASS - EP emergency, fuse - Pre-mounted lamps

56211 3F Cub 4x55 EP CR VT IP64 236 17200 680x680x187

METHACRYLATE - EEI A2 electronic wiring - Pre-mounted lamps

56214 3F Cub 4x55 CR SL IP64 236 17200 680x680x187

METHACRYLATE - EP emergency, fuse - Pre-mounted lamps

56215 3F Cub 4x55 EP CR SL IP64 236 17200 680x680x187

E>70%

Wide distribution.IP64 totally protected against dust.Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Transparent glass VT tempered, non-combustible.SL transparent PMMA flat diffuser.

3F Cub R90 Wide IP43

Code 56200

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56200 3F Cub R90 4x55 CR 236 17200 680x680x187

EP emergency, fuse - Pre-mounted lamps

56203 3F Cub R90 4x55 EP CR 236 17200 680x680x187

3F Cub Fluo

E>91%

Wide distribution.Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Thermal shielding effect from dust in the louvre compartment to maintain optimal efficiency over time.

Page 391: 3F Filippi  "General catalogue 2016"

388

3F Cub IP64 Concentrated

Code 56212

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

GLASS - EEI A2 electronic wiring - Pre-mounted lamps

56212 3F Cub 4x55 CR CONC VT IP64 236 17200 680x680x187

GLASS - EP emergency, fuse - Pre-mounted lamps

56213 3F Cub 4x55 EP CR CONC VT IP64 236 17200 680x680x187

METHACRYLATE - EEI A2 electronic wiring - Pre-mounted lamps

56216 3F Cub 4x55 CR CONC SL IP64 236 17200 680x680x187

METHACRYLATE - EP emergency, fuse - Pre-mounted lamps

56217 3F Cub 4x55 EP CR CONC SL IP64 236 17200 680x680x187

E=68%

Concentrated distribution.IP64 totally protected against dust.Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Transparent glass VT tempered, non-combustible.SL transparent PMMA flat diffuser.

3F Cub R90 IP43 Concentrated

Code 56206

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

56206 3F Cub R90 4x55 CR CONC 236 17200 680x680x187

EP emergency, fuse - Pre-mounted lamps

56208 3F Cub R90 4x55 EP CR CONC 236 17200 680x680x187

3F Cub Fluo

E=89%

Concentrated distribution.Total flow recuperator in specular aluminium, high efficiency, with superficial titanium-magnesium treatment, non-iridescent.Thermal shielding effect from dust in the louvre compartment to maintain optimal efficiency over time.

Page 392: 3F Filippi  "General catalogue 2016"

389Datasheets, product updates and specifications on our website: www.3f-filippi.com

Wate

rpro

of and

co

rro

sio

n-p

roo

f

Wire-guard for indoor dry applications, with double fastening (wire-guard and luminaire), for shocks coming from any directions, not transmitting the shocks to the luminaire but to the ceiling; in galvanized steel rod Ø 5 mm.To install it, ceiling-mounted bracket code A0213 is always necessary.

Code Item

A0210 Wireguard 3F Cub

Accessories

3F Cub

Ceiling-mounted bracket in hot-galvanised steel.

Code Item

A0213 Ceiling-mounted bracket

Page 393: 3F Filippi  "General catalogue 2016"
Page 394: 3F Filippi  "General catalogue 2016"

391

Sp

ecifi

c a

pp

licatio

ns

News and updates available on: www.3f-filippi.com > Products > Specific applications

Specific applicationsPage Product Source Outdoor Interior Railways Metro

392 3F 66392 New 3F 66 LED LED •

394 3F FS394 New 3F FS PC LED LED •

396 3F Metro396 New 3F Metro LED LED •

398 3F1398 3F1 LED • • •

400 3F1 IP64 LED • • •

Page 395: 3F Filippi  "General catalogue 2016"

392

New

3F 66 LEDLED luminaire for outdoor lighting of civil and industrial buildings, porticos and underpasses

Construction characteristics

Illuminotechnical characteristicsDownward bilateral distribution.Lifetime (L85/B10): 30000 h. (Tp 65°C)Lifetime (L80/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Flow recuperator in specular aluminium with superficial titanium-magnesium treatment, non-iridescent.Transparent PMMA diffuser, injection moulded, with smooth outer surface.Sealing gaskets between housing and diffuser in ecological anti-aging EPDM.Tamper-proof diffuser seal with 4 clips to housing, in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz, fuse, class II.In compliance with EN 60598-1.Line entry at rear through rubber seal or at side after drilling.

Dimensions

Applications

Wall mounting, particularly suitable for outdoor lighting of civil and industrial buildings, porticos, underpasses and walkways.Controlled downward bilateral distribution provides uniform lighting on work surfaces.Control of light pollution as per UNI EN 12464-2.

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• LED sources with different colour temperatures

• different powers

A L

H

Page 396: 3F Filippi  "General catalogue 2016"

393Datasheets, product updates and specifications on our website: www.3f-filippi.com

Sp

ecifi

c a

pp

licatio

ns

3F 66 LED

Code 8357

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

8357 New 3F 66 1 LED 6 II 10 474 255x176x344

8358 New 3F 66 2 LED 12 II 16 892 255x176x344

3F 66 LED

E=100%

Page 397: 3F Filippi  "General catalogue 2016"

394

New

3F FS PC LEDLED Luminaire for lighting railway tunnels

Construction characteristics

Illuminotechnical characteristicsDownward bilateral wide distribution.Lifetime (L90/B10): 30000 h. (Tp 65°C)Lifetime (L85/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsSelf-extinguishing V2 polycarbonate housing, injection moulded, RAL 7035 grey.Base in stainless steel, for rapid installation and disinstallation of luminaire without tools (by 4 stainless steel side clips).Flow recuperator in specular aluminium with superficial titanium-magnesium treatment, non-iridescent.Diffuser in transparent self-extinguishing V2 polycarbonate, UV stabilised, injection moulded with smooth outer surface and differentiated prismatic inner surface.Sealing gaskets between housing and diffuser in ecological anti-aging EPDM.Tamper-proof diffuser seal with 2 lateral clips to housing, in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz, fuse, class II.Feeding on the luminaire with cable FG7(O)M1 2x1,5 mm² connected to IP67 mobile connector consists flush mounting box in UL94V0 self-extinguishing thermoplastic resin.Crimp contacts.Gland M20x1,5 self-extinguishing polyamide.In compliance with EN 60598-1.

Dimensions

Applications

Safety lighting for railway tunnels.Controlled bilateral distribution provides uniform lighting on work surfaces.

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• housing in die-cast SG AI Si 2/GD 5076 aluminium alloy, with chrome-free protective treatment, RoHS 2002/95/CE compatible, painted with polyester resin powder, TGIC free, painted Ral 7035 grey for exterior use

• LED sources with different colour temperatures

• fluorescent sources• connectors plug / socket• different powers• emergency

A L

H

Page 398: 3F Filippi  "General catalogue 2016"

395

15 m

12 lx3,5 lx12 lx 2,5 m

11,40 m

2,5 m

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Sp

ecifi

c a

pp

licatio

ns

3F FS PC LED

Code 8330

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

8330 New 3F FS PC LED 1x4W-350 AM II 6 410 255x174x360

3F FS PC LED

E=100%

Example of typical installation for railway galleriesSafety lighting in lux, obtained with luminaires installed on two sides of the gallery, in staggered sequence.

- Guarantees safe lighting, even with very wide spacing,thanks to the special design of the recuperator.

- Extremely easy maintenance thanks to rapid removal, with stainless steel clips, from the brackets attached to wall.

- Luminaire is highly resistant to stress and to vibrations caused by passing trains.

Page 399: 3F Filippi  "General catalogue 2016"

396

New

3F Metro LEDLED luminaire for lighting tube tunnels

Construction characteristics

Illuminotechnical characteristicsDownward bilateral wide distribution.Lifetime (L80/B10): 30000 h. (Tp 65°C)Lifetime (L70/B10): 50000 h. (Tp 65°C)Photobiological safety RG0, risk absent, in compliance with IEC 62471.

Mechanical characteristicsSelf-extinguishing V0 polycarbonate housing, injection moulded, grey RAL 7035.Upper base with wall mount, in galvanised steel.Galvanised steel base anchored to housing, slotted for rapid installation/removal of luminaire.Deep flow recuperator in specular aluminium with superficial titanium-magnesium treatment, non-iridescent.Diffuser in transparent selfextinguishing V0 polycarbonate, UV stabilised, injection moulded with smooth outside and differentiated prismatic inner surface.Sealing gaskets between housing and diffuser in ecological anti-aging EPDM.Tamper-proof diffuser seal with 4 clips to housing, in stainless steel.Drilling template in stainless steel.

Electrical characteristicsElectronic wiring 230V-50/60Hz, fuse, class II.In compliance with EN 60598-1.Plug/socket IP67, fG7(O)M1 2x1.5 mm² cable, M20x1.5 cable gland in self-extinguishing polyamide.Line input on fixed socket with M25x1.5 threaded hole and polyamide cable gland with 10-17mm diameter tightening range.

Dimensions

Applications

Safety lighting for subway tunnels with wall fixing.Housing and diffuser are in Polycarbonate UL94 V0, certified by the french laboratory SAFRAN for fire reaction, harmful gas and smoke emission.

Source characteristics

• LED modules, CCT nominal color temperature 4000 K, color rendering index CRI >80.

• Color initial tolerance (MacAdam): 3.

On request

• different powers• LED sources with different colour

temperatures• emergency• other types of connections• fluorescent sources

**

LA

H

Page 400: 3F Filippi  "General catalogue 2016"

397

8,80 m

10 m

2 m

2 m 43 lx11 lx43 lx

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Sp

ecifi

c a

pp

licatio

ns

3F Metro LED

Code 8366

Code Item Absorbed

power (W)

Output

flux (lm)

Dimensions

L x A x H

Electronic

8366 New 3F Metro 1 LED 8 AMPIO II 12 731 469x189x350

3F Metro LED

E=100%

Example of typical installation for subway tunnelsOrdinary lighting in lux, obtained with luminaires installed on two sides of the tunnel, in staggered rows.

- Guarantees ordinary lighting, even with very wide spacing, thanks to the special design of the recuperator.

- Housing and diffuser certified SAFRAN for fume emission and fire response.

- Extremely easy maintenance thanks to rapid removal.- Luminaire is highly resistant to stress and to vibrations caused

by passing trains.

Page 401: 3F Filippi  "General catalogue 2016"

398

3F1 Single

Capacity

2250

mm2

3F1 Double

Capacity

5485

mm2

Capacity

8650

mm2

Multifunctional lighting system

Electric wiring distribution for:Mains supplyTelephone and data distribution networksSmoke and fire detectorsBurglar alarm systemsIntrusion detection systemsAntitheft devices for goodsSound diffusion

Suitable also forrunning UTP/FTPcat 6 network cabling.

Check, according to quantityand type of cables to be housed,the possibility to use3F1 Single or 3F1 Double.

For detailed information on the series,consult our website at www.3f-filippi.it

3F1

Patented

Page 402: 3F Filippi  "General catalogue 2016"

399

Sp

ecifi

c a

pp

licatio

ns

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F1

Page 403: 3F Filippi  "General catalogue 2016"

400

For more detailed information on this product range, consult our website at www.3f-filippi.it

3F1 IP64 Single in SP version 3F1 IP64 Double in VS version

Multifunctional lighting system suitable for waiting or transit areas, platform-roof, underpasses, where IP64 ingress protection is required.The structure is in hot-galvanised steel painted in RAL 9006 colour and can be installed on the ceiling or suspended.

The structure (IP40 rated) contains IP64 luminaires in the VS version with stainless-steel frame and moulded glass, or SP version with polycarbonate diffuser.

Multifunctional lighting system with high IP rating

3F1 IP64

Patented

Page 404: 3F Filippi  "General catalogue 2016"

401

Sp

ecifi

c a

pp

licatio

ns

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F1 IP64

Application in collective spaces

Application in railway stations

Application in industrial areas

Page 405: 3F Filippi  "General catalogue 2016"
Page 406: 3F Filippi  "General catalogue 2016"

403

Healthcare

ap

plic

atio

ns

News and updates available on: www.3f-filippi.com > Products > Healthcare applications

Healthcare applicationsPage Product Source Bedhead Air cleaning

404 3F Relax404 3F Relax Fluo •

406 LUCECURA406 LUCECURA Fluo •

408 3Fine Germicide408 3Fine Germicide Fluo •

Page 407: 3F Filippi  "General catalogue 2016"

404

3F RelaxBedhead range for hospital rooms or nursing facilities

Construction characteristics

Illuminotechnical characteristicsAsymmetrical direct light distribution for reading and examination light and indirect for general room lighting.

Mechanical characteristicsHousing in boxed steel, painted white.Front profile in extruded aluminium with rounded edges, painted white, resists all commonly used disinfectants and detergents.Rounded heads in aluminium.Housing contains both lighting and electrical systems.High-efficiency flow recuperator, for direct and indirect lighting, in specular aluminium with titanium-magnesium surface treatment, non-iridescent.Lower diffuser in transparent PMMA, prismatic interior, anti-glare.Upper diffuser in smooth transparent PMMA.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.Heatresistant wire, HT 90°C, CEI 20-20 and wire N07V-K section 1.5/2.5 mm² to connect electrical units.Line input along entire length of luminaire.Nylon line connection terminal block, equipotential terminal for conductor with max. section of 16 mm².In compliance with UNI EN ISO 11197 and EN 60601-1.

Dimensions

Notes

• Servizi elettrici Bticino serie Matix bianca su placche in resina colore avorio.

3F Relax 1500 and 1800• On one end: bypass socket

2x10/16A+PE with protective fuse, examination light switch, hanging button panel to call nurse and to switch-on reading light, ID pilot lamp.

• On the other end: Schuko bypass socket UNEL 2x10/16A+PE with protective fuse.

3F Relax 1000• On one end: bipolar switch for reading

light, blind cap, pull button for call.• On the other end: blind cap, bypass

socket 2x10/16A+PE with protective fuse.

Source characteristics

• T5 electronic fluorescent lamps, CCT nominal color temperature 4000 K, color rendering index CRI >80.

On request

• other lamp types, luminaires suitable for continuous channels

• hook for IV drip• housing in different RAL colours• night light• equipotential outlet• wiring: dimmable• 3F Relax 1000 hanging button panel to

call nurse and to switch-on reading light, ID pilot lamp, relay

AL

H

Page 408: 3F Filippi  "General catalogue 2016"

405

1000500

1500750

1800 1800 1800

1800900

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Healthcare

ap

plic

atio

ns

3F Relax

Code 9210

Code Item Dimensions

L x A x H

EEI A2 electronic wiring - Pre-mounted lamps

9210 3F Relax 1000 1x39 Ind + 1x39 Dir T5 LD HF 1000x130x170

9238 3F Relax 1500 1x49 Ind + 1+1x14W Dir T5 LD HF 1500x130x170

9239 3F Relax 1800 1x49 Ind + 1+1x14W Dir T5 LD HF 1800x130x170

3F Relax

Indirect E>84%

Direct E>68%

Installation

3F Relax 1000 3F Relax 1500 3F Relax 1800

Page 409: 3F Filippi  "General catalogue 2016"

406

LUCECURABedhead range for hospital rooms with compartment for medical gases

Construction characteristics

Illuminotechnical characteristicsAsymmetrical direct light distribution for reading and examination light and indirect for general room lighting.

Mechanical characteristicsHousing in extruded aluminium with rounded edges, painted white, resists all normally used disinfectants and detergents.Housing is divided into three separate compartments: upper for lighting, central for electrical services, lower reserved for distribution of medical gases.Flux recuperator in highreflecting aluminium for indirect lighting.Lower diffuser in transparent polycarbonate, prismatic interior, anti-glare.Upper diffuser in transparent polycarbonate.

Electrical characteristicsEEI A2 electronic wiring, 230V-50/60Hz, lamp warm start.In compliance with UNI EN ISO 11197 and EN 60601-1.Heat-resistant cable, HT 90°C, CEI 20-20 and cable N07V-K with section 1.5 / 2.5 / 4 mm² for electrical utilities connection.Line connection terminal block on DIN rail, with equipotential terminal for conductor with max. section of 16 mm².In compliance with UNI EN ISO 11197 and EN 60601-1.

Dimensions

Notes

Each bed has the following electrical systems:• Biticino Magic series on ivorycoloured

resin plates and button panel to call medical staff.

• Hanging button panel to call nurse and to switch-on reading light, ID pilot lamp, relay, UNEL and 2x10/16 A+E bypass socket with protective fuses, examination light switch, 2 sliding polycarbonate hooks to hang button panel.

On request

• housing in RAL colour• gas box• equipotential outlet• night light• dimmable wiring

L A

H

Page 410: 3F Filippi  "General catalogue 2016"

407

1700

450

1700

45036W = 1554*58W = 1864*

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Healthcare

ap

plic

atio

ns

LUCECURA

Code 9146

Code Item Dimensions

L x A x H

For 1 bed - Electronic MultiWatt EEI A2 - Lamps not included

9146 New LUCECURA 1x35-49-80 Ind + 1x14-24 DX Dir T5 HF 1870x155x241

9147 New LUCECURA 1x35-49-80 Ind + 1x14-24 SX Dir T5 HF 1870x155x241

For 2 beds - Electronic MultiWatt EEI A2 - Lamps not included

9150 New LUCECURA 2x35-49-80 Ind + 1x14-24 DX Dir T5 HF 3724x155x241

9151 New LUCECURA 2x35-49-80 Ind + 1x14-24 SX Dir T5 HF 3724x155x241

For 3 beds - Electronic MultiWatt EEI A2 - Lamps not included

9154 New LUCECURA 3x35-49-80 Ind + 1x14-24 DX Dir T5 HF 5598x155x241

9155 New LUCECURA 3x35-49-80 Ind + 1x14-24 SX Dir T5 HF 5598x155x241

LUCECURA

Indirect E>76%

Direct E>31%

Power supply input: DX = right, SX = leftCertifications for this product can be downloaded from our website.

InstallationOn 1 bed On 2 beds

(*repetitive heights on 3 beds on request)

Page 411: 3F Filippi  "General catalogue 2016"

408

3Fine GermicideLuminaire for sterilisation of environments

Construction characteristics

Illuminotechnical characteristicsThe luminaires are designed for use with linear germicide lamps, 15W or 30W.Indirect irradiation upwards.

Mechanical characteristicsSingle-piece pressed steel housing, phosphate degreasing treatment using iron salts, electrophoresis painted in white oven dried enamel.Parabolic flux recuperator in semispecular anodised aluminium necessary to obtain maximum irradiation.

Electrical characteristicsEEI B2 low loss starter wiring, 230V-50Hz, power factor correction, fuse.In compliance with EN 60598-1.

Dimensions

Applications

Suitable for installation in environments to be sterilised thanks to the lamps’ UV action which destroys bacteria, viruses, germ spores and moulds.Direct exposure to this type of radiation can cause skin flammation or irritation of the eyes and mucous membranes.

Installation

Direct wall-mounted.It is recommended you install the luminaire with the lamp in the lower part (see diagram in dimensions box), at a height no less than two metres from the floor, so that the rays do not irradiate the normal field of vision of those working in the environment.

Source characteristics

The linear germicidal lamps are not supplied.The suitable ones for this product range are: Osram Puritec (HNS 15W G13 - HNS 30W G13) and Philips TUV T8 (TUV TL-D 15W - TUV TL-D 30W).

LA

H

Page 412: 3F Filippi  "General catalogue 2016"

409Datasheets, product updates and specifications on our website: www.3f-filippi.com

Healthcare

ap

plic

atio

ns

3Fine Germicide

Code Item Absorbed

power (W)

Sources

flux (lm)

Dimensions

L x A x H

Starter EEI B2, fuse - Lamps not included

1949 3FI GER 1x15 519x90x197

1950 3FI GER 1x30 952x90x197

3Fine Germicide

Page 413: 3F Filippi  "General catalogue 2016"

41041414141441414141414444144141414141414414441414141414444144444444444444444444 0000000000000000000000000000000

Page 414: 3F Filippi  "General catalogue 2016"

411411

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com > Products > Light Management

3F Easy Dim

Page

414 Overview

415 Installation examples

416 Accessories

Light ManagementPage

412 Overview

3F SensorPage

418 Overview

419 Technical details 3F Sensor / 3F Sensor CF

3F Smart DimmingPage

420 Overview

421 Installation Reference - Corridor Function

422 Installation Reference - Office / Open space

423 Installation Reference - Industrial / Gymnasiums

424 Installation Reference - School classroom

425 Accessories

3F HCLPage

428 Overview

430 Technical details

431 Accessories

3F & KNXPage

432 Overview

3F CLOPage

433 Overview

Page 415: 3F Filippi  "General catalogue 2016"

412

Light Management

3F Filippi is always at the forefront of energy savings and improving the efficiency of systems: this is why we are constantly striving to create luminaires which are able to interact with environments and with the people who live and work there.

One of the most important aspects of managing workplaces is certainly the lighting: it is indeed proven that poor illumination is not only harmful to workers, but creates both direct (higher power consumption or waste) and indirect (worker illness, decreases in productivity, stress or even physical issues) economic problems.

Good lighting may often seem difficult to obtain, but in reality small measures can obtain big results.Here are three useful tips:

• Let in the sun: natural light improves quality of life and saves you money!• Use low-energy sources: luminaires fitted with fluorescent and LED sources are the best weapons in cutting costs, especially when

they are optimised like those manufactured by 3F Filippi.• Use luminaires with luminous fluxes which can be regulated according to requirements: dimming the luminaires lets you lower

electricity consumption by up to 80%, at the same time creating a more pleasant and functional working environment

Systems which are able to regulate the artificial lighting on the basis of the available natural light can be created, using only the power required to maintain an appropriate level of lighting in the environment, allowing you to save up to 80% on electricity bills.After performing analyses alongside lighting designers, we noticed that adopting control systems which can regulate lighting on the basis of the available natural light provides wide margins for improving the energy efficiency of systems, particularly during the summer months.Adopting systems such as KNX - which can also be used throughout the building for automating all types of systems (HVAC, lighting, opening, blinds etc.) - combined with measurement of the natural light level provides excellent results, in part due to intelligent positioning of light measurement sensors in relation to the position of the workplace and geographical orientation.

3F Filippi offers light regulation systems to help you save energy and protect the environment: from manual regulation systems to luminaires able to turn on and off thanks to integrated brightness and presence sensors, energy management systems linked to building automation, right through to components which help you to create made-to-measure lighting installations with ease.

3F Filippi is at your side to offer you the best solutions both for your environment and your workers.

Good for you, excellent for the environment.

Page 416: 3F Filippi  "General catalogue 2016"

413

3F Smart Lighting

3F Sensor 3F Smart Dimming

3F CLO 3F & KNX

3F Easy Dim 3F HCL

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Light Management

These lighting management systems comply with UNI EN 15232 "Energy performance of buildings. Impact of Building Automation, Controls and Building Management" which introduces four energy efficiency categories for the control functions of building technical systems.

Introducing 3F Smart Lighting control and light management systems - even in systems already equipped with high-efficiency light sources - can provide significant further energy efficiency improvements.

A great advantage of automated systems, like 3F Sensor and 3F Smart Dimming, is that regulation is completely automatic, without any requirement for operators to intervene, ensuring that the systems is constantly adapting itself to the required conditions.

Automatic system for turning luminaires on and off thanks to integrated presence and brightness sensors.

Components for creating luminous flux regulation systems with examples divided by sector of application.

Automatic regulation system which compensates for the decline in luminous flux, providing a constant level of lighting

over time.

Characteristics and luminaires able to interface with KNX, the standard for automated remote management of the technological systems of a building.

Manual regulation systems which allow you to adjust the luminous flux of the luminaires.

Check for the variation of the white light colour temperature which follows the natural cycle of the light.

The results which can be obtained must be combined with correct integration of building and electrical design which can provide the base elements necessary to justify adoption of any automation system.

Both for new builds and for existing systems, the costs of implementing these solutions are more than offset by simplification of the electrical wiring and corresponding installation: this reduction in conductors, conduits, power and control switchboards means that the time required to see a return on investment is drastically reduced.

Our sales and technical offices are at your disposal to support you in choosing the best solutions available; these can also be customised to the application you require.

3F Filippi lighting and Smart Buildings

Page 417: 3F Filippi  "General catalogue 2016"

414

Characteristics

3F Easy Dim technology lets you regulate luminous flux in an easy, low-cost and customisable manner.In terms of the system, it is composed of a commercially available push-button (up to 6 ballasts) and a DALI repeater (to manage up to 64 ballasts). This mode allows you to perform the following functions:

• Turning the luminaire ON/OFF• Manual regulation of the luminaire's luminous flux on the basis of specific requirements.

3F Easy Dim

Savings in your hands

Advantages

The advantage of this technology is that it gives the user the possibility to customise the quantity of light present in the environment depending on taste and requirements, while using genuinely low-cost components. The control provided is manual, and as such savings will depend on how it is managed.

Savings

• Installation phase: up to 6 ballasts, controlled via a commercially available push-button. Between 7 and 64 ballasts requires a DALI repeater.

• Use: if the luminous flux output is below 100%, power consumption of the luminaire is significantly reduced.

Page 418: 3F Filippi  "General catalogue 2016"

415

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Up to 6 ballasts

3F Easy Dim

Results obtainable- Manually turning the luminaire ON/OFF- Manual regulation of the luminaire's luminous flux on the basis of user requirements.

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast.

Components required- 1 commercial push-button

Note: in environments where there is signal interference present, and with dimmer wire lengths of over 20 metres, the installation of a DALI repeater is advisable.

Up to 64 ballasts

Results obtainable- Manually turning the luminaire ON/OFF- Manual regulation of the luminaire's luminous flux on the basis of user requirements.

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast.

Components required- 1 commercial push-button- 1 DALI repeater

ECG DALI

ECG DALI

ECG DALI

DALI REPEATER

ECG DALI

Push-button

Push-button

Page 419: 3F Filippi  "General catalogue 2016"

416

Box mounted housing DALI Repeater ext (cod. A3008), size 261x71x27 mm.

Code Item

A3010 New Box for Repeater DALI

Signal Repeater for expansion of DALI systems (64 drivers - 300 meters of line), size 96x72x62 mm, DIN rail mounting.

Code Item

A3009 New Repeater DALI DIN

Accessories

3F Easy Dim

Signal Repeater for expansion of DALI systems (64 drivers - 300 meters of line), size 189x30x21 mm, integrated installation into the device or into the Box (cod. A3010).

Code Item

A3008 New Repeater DALI ext

Page 420: 3F Filippi  "General catalogue 2016"

417

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Page 421: 3F Filippi  "General catalogue 2016"

418

3F SensorA small revolution bringing you big advantages.

Characteristics

Sensor technology allows you to make savings and manage your lighting systems in an easy, low-cost and customisable manner without investing significant capital in costly systems.What we have done is really very simple: we have included what was previously outside the luminaire, inside it. This means that the products in this range have functions such as:

• Turning on the luminaire on the basis of the chosen level of brightness• Turning on the luminaire when there are people in the luminaire's operating range• Manual regulation of the luminaire's on time, on the basis of specific requirements.

Advantages

The advantages of this technology create significant savings for the end customer:• Time savings during installation: integrating these functions inside the luminaire means it is no longer necessary to install a network

of sensors (and corresponding wiring) and connect it to the luminaires• Cost savings: you save money on installation time, electrical supplies and system calibration time.• Ease of installation: it is no longer necessary to create or modify electrical systems. Just connect the luminaires to the mains • Customisation of brightness levels: each luminaire "works" independently from the others, allowing you to create "made to

measure" lighting

You can think of products equipped with Sensor technology as independent units which are able to work together in a network, even though they are not physically connected.

Savings

In practical terms, the advantages are real and tangible in these aspects for the end customer:• Installation: To create a network of luminaires, it is no longer necessary to connect them physically; this means you no longer have to

spend extra for wiring supplies and installation time.• Independence and precision: Each luminaire is independent; this means that lights turn on in an increasingly localised and precise

manner, with corresponding electricity savings.• Simplicity: Dimming and presence sensors are integrated and already operational. All that is left for you to do is to connect the phase,

neutral and earth wires: wasting time setting up and adjusting the system is a thing of the past!• Integration with existing installations: the same lighting connections, using standard electrical wiring: this means not wasting

money adapting the systems.

3F Sensor: saves you money even before the light is turned on.

Versions Sensor Corridor Sensor Function

Standard position Luminaire offKept on

at 10% power

Automatic Via set light level and presence sensor

Mounting height Wall installation at max 2.7 metres - Ceiling installation at max 4 metres

Adjustment of twilight function Daylight / 300 lux / 150 lux / Twilight / Night / Programmable mode

On time adjustment From 10 seconds to 30 minutes

Adjustment of the detection levelof the sensor 20% - 30% - 50% - 75% - 100%

Page 422: 3F Filippi  "General catalogue 2016"

419

T1

T3

T2

T1

T5

T3

T2

T4

3F SSeennssoorr

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Standard position: the power output of the luminaires is dimmed to 10%,

thus obtaining a minimum level of lighting.

As soon as the luminaires detect the presence of persons, or the level

of natural light falls below a minimum set threshold, the CF function is

activated and they switch to 100% power output for the set duration (this

can be regulated during installation).

3F Sensor

3F Sensor

Sensitivity

1.8 m

2.6 m

Luminairewall installation

Luminaireceiling installationup to 10 m

up to 10 m

Results obtainable- Luminaire ON/OFF via relay sensor- Activation of the luminaire's luminous flux depending on the amount of natural light and/or presence of personnel

Available luminaires3F Petra LED Sensor, 3F Linda LED Sensor

Operation graph

Legend:

T1 >

T

2 - latency time managed by the sensor - adjustable

T2 >

T

3 - period of zero luminous flux - unlimited time

100%

0%

time

presence

3F Sensor CF

Results obtainable- Luminous flux of 10% at rest, 100% flux when presence is detected via relay sensor- Activation of 100% of luminous flux depending on the amount of natural light and/or presence of personnel

Available luminairesL 320 LED Sensor CF, 3F Linda LED Sensor CF

Operation graph

Legend:

T1 >

T

2 - latency time managed by the sensor - adjustable

T2 >

T

3 - latency time managed by the driver - 120 seconds

T3 >

T

4 - luminous flux decrease time - 32 seconds

T4 >

T

5 - period of minimum luminous flux - unlimited time

100%

10%

0%

time

presence

Page 423: 3F Filippi  "General catalogue 2016"

420

3F Smart Dimming

Characteristics

Smart Dimming technology allows you to make savings and manage your lighting systems in an easy, low-cost and customisable manner without investing significant capital in costly systems.Products in this range have functions such as:

• Turning on and automatically regulating the luminaire on the basis of the chosen level of brightness• Turning on the luminaire when there are people in the luminaire's operating range• Manual regulation and ON/OFF via accessory remote controls or push-buttons

Advantages

The advantages of this technology offer significant energy savings for the end customer, calculated as being up to 80% compared to an on-off solution. It is also possible to create made-to-measure lighting based on the requirements of the environment and the light level

required.

Savings

In practical terms, the advantages are real and tangible in these aspects for the end customer:• Quick, simple installation• Energy savings• Reduced time to see return on investment

Page 424: 3F Filippi  "General catalogue 2016"

421

T1

T5

T3

T2

T4

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Installation Reference - Corridor Function

Results obtainable• Luminous flux of 10% at rest, 100% flux when presence is

detected via relay sensor• Activation of 100% of luminous flux depending on the

amount of natural light and/or presence of personnel

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast with Corridor Function (to be specified when ordering).

Components required• Luminaire with DALI driver with Corridor Function• IR adaptor for Smartphones (optional)• 1 on-off Sensor A or 1 on/off-ext Sensor A (range of

operation 10 metres)

or

• 1 on-off Sensor B or 1 on/off-ext Sensor B (range of operation 24 metres)

Operation graph

Wiring diagram

Legend:

T1 >

T

2 - latency time managed by the sensor - adjustable

T2 >

T

3 - latency time managed by the driver - 120 seconds

T3 >

T

4 - luminous flux decrease time - 32 seconds

T4 >

T

5 - period of minimum luminous flux - unlimited time

100%

10%

0%

time

presence

ECG DALI

ECG DALI

Sensore di presenza

ON-OFF

3F Smart Dimming

Page 425: 3F Filippi  "General catalogue 2016"

422

Note:to deactivate presence sensing, R and L must be short circuited directly on the sensor.

3F Smart DimmingInstallation Reference - Office / Open space

Wiring diagram

Up to 50 ballasts - Installation height up to 4 metres

Results obtainable• Manual ON/OFF/regulation of the luminaire via optional

remote control or push-button• Automatic regulation of the luminaire’s light flow

depending on the amount of natural light and/or presence of personnel

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast.On request, can also be implemented with 1-10V components (drivers and sensors).

Components required• 1 commercial push-button• Luminaire with DALI driver• 1 DALI Sensor A (recessed) or DALI ext Sensor A (ceiling

mount)• IR adaptor for Smartphones (optional)• IR programmer (optional)• IR remote control (optional)

ECG DALI

Push-button

ECG DALI

Sensore

Page 426: 3F Filippi  "General catalogue 2016"

423

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Installation Reference - Industrial / Gymnasiums

Up to 50 ballasts - Installation height between 4 and 9 metres

Wiring diagram

Up to 50 ballasts - Installation height between 4 and 9 metres

Results obtainable• Manual ON/OFF/regulation of the luminaire via optional

remote control or push-button• Automatic regulation of the luminaire’s light flow

depending on the amount of natural light and/or presence of personnel

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast.On request, can also be implemented with 1-10V components (drivers and sensors).

Components required• 1 commercial push-button• Luminaire with DALI driver• 1 DALI Sensor B (recessed) or DALI ext Sensor B (ceiling

mount)• IR adaptor for Smartphones (optional)• IR programmer (optional)• IR remote control (optional)

ECG DALI

Push-button

ECG DALI

Sensore

3F Smart Dimming

Page 427: 3F Filippi  "General catalogue 2016"

424

Note:to deactivate presence sensing, R and L must be short circuited directly on the sensor.

Up to 50 ballasts

3F Smart Dimming

Wiring diagram

Installation Reference - School classroom

Results obtainable• Manual ON/OFF/regulation of the luminaire via optional

remote control or push-button• Automatic regulation of the luminous flux of the

luminaires in a differentiated manner depending on the natural light present in two different areas: a single sensor measures the brightness at two points (for example, near the window and in the darkest area of the classroom), and adjusts the fluxes of the luminaires lighting those areas as a consequence

Compatible luminairesAny luminaire from the 3F Filippi range, as long as it is equipped with DALI ballast.On request, can also be implemented with 1-10V components (drivers and sensors).

Components required• 1 commercial push-button• Luminaire with DALI driver• 1 Dual-DALI Sensor B• IR adaptor for Smartphones (optional)• IR programmer (optional)• IR remote control (optional)

Channel 1

Channel 2

Push-button

Sensore

ECG DALI

ECG DALI

Page 428: 3F Filippi  "General catalogue 2016"

425

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Presence detector with remote control, circular detection area Ø24m, with master and DALI interface function.Integrated light sensor for automatic constant light control.Drive up to 50 digital electronic driver groups.Available in recessed and surface-mounted version (ext).IP20 for recessed version.IP54 (visible part) for the “ext” surface-mounted version.

Code Item

A3016 New Sensor B DALI ext

A3017 New Sensor B DALI

On request, kit to obtain a protection degree of IP54 (for “ext” version only).

Presence detector with remote control, circular detection area Ø10m, with master and DALI interface function.Integrated light sensor for automatic constant light control.Drive up to 50 digital electronic driver groups.Available in recessed and surface-mounted version (ext).IP20 for recessed version.IP54 (visible part) for the “ext” surface-mounted version.

Code Item

A3011 New Sensor A DALI

A3012 New Sensor A DALI ext

On request, kit to obtain a protection degree of IP54 (for “ext” version only).

Presence detector 230 can be controlled remotely, circular detection area Ø24m, with Master feature.Integrated light sensor.Available in recessed and surface-mounted version (ext).IP20 for recessed version.IP54 (visible part) for the “ext” surface-mounted version.

Code Item

A3018 New Sensor B on/off

A3019 New Sensor B on/off-ext

On request, kit to obtain a protection degree of IP54 (for “ext” version only).

Accessories

3F Smart Dimming

Presence detector 230 can be controlled remotely, circular detection area Ø10m, with Master feature.Integrated light sensor.Available in recessed and surface-mounted version (ext).IP20 for recessed version.IP54 (visible part) for the “ext” surface-mounted version.

Code Item

A3013 New Sensor A on/off

A3014 New Sensor A on/off-ext

On request, kit to obtain a protection degree of IP54 (for “ext” version only).

Page 429: 3F Filippi  "General catalogue 2016"

426

IR Adapter for Smartphones, compatible with all sensors. Free APP available for Android and iOS devices.

Code Item

A3022 New IR-Adapter for Smartphone

IR remote control per user, compatible with DALI sensor A, sensor B Dual-DALI and sensor B DALI.

Code Item

A3021 New Remote controller IR

IR remote control programmer, compatible with DALI sensor A, sensor B Dual-DALI and sensor B DALI.

Code Item

A3020 New Programmer IR

Accessories

3F Smart Dimming

Presence detector with remote control, circular detection area Ø24m, with master function and two DALI interfaces. Two light sensors for automatic adjustment of light constant. Drive up to 50 digital electronic driver groups. Available in the recessed version.

Code Item

A3015 New Sensor B Dual-DALI

Page 430: 3F Filippi  "General catalogue 2016"

427

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Page 431: 3F Filippi  "General catalogue 2016"

428

People and their requirements have always been at the centre of our attention when designing our products.

Thanks to the new HCL luminaires, ensuring the comfort and health of the individual finds a new point of reference thanks to a solution which can actively stimulate biorhythms.

Natural light is one of the most important sensory stimuli for our body, and it also has an enormous effect on our mental and emotional state. For this reason, HCL luminaires have been designed to replicate natural light, taking the following requirements into consideration:

• Dynamism of light over time• Dynamism of colour temperature over time• Symmetrical light diffusion• Freedom of use for each individual

3F HCLThe difference between seeing and feeling the effect of the Light

The latest research in the sector has shown that those who work in environments with windows and good lighting are exposed to 173% more natural light during working hours and sleep on average 46 minutes longer (each night) compared to others, as they are less affected by problems such as insomnia. The result is a general increase in well-being.

There is ever-increasing evidence to support the fact that exposure to light during the day, particularly during the morning, is beneficial to health in terms of its effects on mood, mental lucidity and the metabolism:

Hospitals

In healthcare facilities, Human Centric Lighting can:

• reduce sleep disturbances, thus limiting the need for drugs and reducing medical assistance requirements

• improve patient well-being and activity during the day

Offices

In offices, Human Centric Lighting technology can increase employees' motivation and energy, improving day-to-day productivity, particularly in the period after lunch.What's more, in environments without natural light, it can help recreate daily biorhythms.

Schools

In schools, Human Centric Lighting technology can significantly improve concentration and cognitive performance.A 45% reduction in errors and a 9% improvement in cognitive speed have been demonstrated.

CommercialPremises

In commercial situations, Human Centric Lighting offers the possibility to diversify light distribution and colour on the basis of scenarios linked to the products or concepts being presented.This provides a flexibility of use at each point of sale which offers savings in terms of time and money.

Individual well-being is strictly personal, and so this luminaire is managed by a control unit (external and not included with the product) which provides everyone the possibility to create "their own light cycle" which best meets their requirements.

If you require more information, do not hesitate to contact our Sales Network or our Technical Offices.

Technology

HCL3F Filippi

Page 432: 3F Filippi  "General catalogue 2016"

429

3000K 4000K 5000K 6500K

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Light influences mood and can trigger both positive and negative emotions.

HCL luminaires provide users with the possibility to change both intensity and temperature of the emitted light, thus improving comfort and increasing the feeling of well-being.

A third photoreceptor in the human eye was discovered in 2001, which is responsible for our light response for regulating our biological clock and circadian rhythms.

Recent studies (performed by Lighting Europe) have shown that HCL luminaires improve concentration as well as the safety and efficiency of the workplace or training and school environments. For this reason, 3F Filippi has decided to create a series of new luminaires to help people feel better by putting their requirements at the centre of the design, also from a biological point of view.

3F HCL

In order to take proper advantage of these luminaires, it is essential that:• The artificial light follows the cycle of the natural light• The management systems can also be manually adjusted, according to each user’s sensitivity.• Right from the lighting design stage, factors such as exposure of the environment to natural light, the users’ biological situations and

the tasks they must perform are taken into account.• 3F Filippi recommends you always consult a qualified and reliable lighting designer.

Biorhythms depend on signals which derive from the quantity and the quality of natural light and the environmental colour temperature:

Stimulation to relax Stimulation to be active

The brain is stimulated:• By cold light present during daylight hours (6,500 K) which allows us to be more active and concentrate harder.• By warm light present in the morning and evening (2,700K) which induces greater relaxation.

Thanks to HCL technology, everyone can improve their sleep cycles, mental and emotional states by themselves.

HCL technology allows for:

Characteristics:• Control for variation of the white colour temperature (Tunable-white)• Simulated changing of daylight over the course of the day• Modulation of the colour temperature along the Planck curve from 2700K to 6500K• Colour rendering index CRI >85• Colour tolerance: 3 MacAdam ellipses• LED source luminous efficiency - up to 155 lm/W

Comfort and well-being, particularly in environments in which a lot of time is spent.

Lighting which follows the natural daylight cycle.

Less environmental stress reduces physical and mental exertion.

Automatic and/or manual management of the light intensity and colour temperature.

BiologicalEffects

Emotional Effects

BiologicalEffects

Page 433: 3F Filippi  "General catalogue 2016"

430

3F HCLThe difference between seeing and feeling the effect of the Light

Manual control

Results obtainable• Manual ON/OFF• Manual control of colour temperature

Compatible luminairesL 320 LED HCL, L 390 LED HCL, 3F Travetta LED HCL

Components required1. 2 commercially available push-buttons (1 for regulation

of the colour temperature and 1 for regulation of the brightness)

2. 1 HCL Basic Controller (code A3001)

Automatic control

Results obtainable• Manual or automatic ON/OFF• Automatic control of colour temperature which

follows circadian rhythms with programming via a free APP (available for iOS and Android)

• Manual control of the colour temperature via push-buttons or Touch Panel

Compatible luminairesL 320 LED HCL, L 390 LED HCL, 3F Travetta LED HCL

Components required• 1 HCL Plus Controller (code A3002)• 1 HCL Touch Panel (code A3003) or alternatively 1 Clock

Modulo (code A3004)

optional components

• 2 commercially available push-buttons (1 for regulation of the colour temperature and 1 for regulation of the brightness)

Page 434: 3F Filippi  "General catalogue 2016"

431

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Automatic Interface (only manageable with buttons) with on / off function, color temperature adjustment, light intensity and on / disattivaizone of the circadian cycle, even from smartphones manageable.

Code Item

A3004 New Clock Module

Automatic Interface with touch-sensitive monitor with on / off function, color temperature adjustment, light intensity and on / disattivaizone of the circadian cycle, even from smartphones manageable.

Code Item

A3003 New Touch Panel HCL

Controller for automatic adjustment of the color temperature (circadian cycle), dimensions 130x30x21 mm.To be used in combination to the Clock Module (cod. A3004) or Touch Panel HCL (cod. A3003).

Code Item

A3002 New Controller HCL Plus

Accessories

3F HCL

Controller for manual adjustment of the color temperature, size 130x30x21 mm.

Code Item

A3001 New Controller HCL Basic

Page 435: 3F Filippi  "General catalogue 2016"

432

3F &

3F & KNXNetworking has never been so easy.

Characteristics

KNX is a worldwide open standard which meets the most important European and international standards and offers automated and decentralised management of technological systems for: commercial, industrial, public and office buildings, schools and many other structures besides.

KNX can be used in all applications and for control functions in buildings: from lighting to blinds, security, HVAC supervision, control of plumbing and alarms, energy management, electricity meters, domestic appliances, audio systems etc.

KNX improves comfort and security, as well as providing a strong contribution to energy savings (up to 50% for lighting and heating management) and to reducing environmental impact.The KNX system can be used both in new and existing buildings. KNX installations can be easily expanded and adapted to meet new requirements, quickly and with minimal financial investment (for example when new tenants enter a commercial building).

Example connection diagrams:

3F Filippi really believes in this standard, and it is for this reason that we offer a range of luminaires equipped with DALI ballasts which are able to interface with KNX systems seamlessly: the connection between the network and the luminaire occurs via gateways which allow information and commands to be transmitted via the LAN network.

Gateway

DALI/KNX

ECG DALI

ECG DALI

Page 436: 3F Filippi  "General catalogue 2016"

433

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

Lig

ht

Manag

em

ent

Datasheets, product updates and specifications on our website: www.3f-filippi.com

In order to guarantee the minimum lighting levels required by standards, the illuminotechnical testing is performed using LED luminous flux values which are reduced by the maintenance factor which takes into account the decrease in this flux at 50,000 hours.This means that the system, from the first hours of its life until it reaches 50,000 hours, will guarantee greater lighting levels than those required and will consume more power than necessary, wasting 15% of energy in the first years of operation (around 10% on average throughout its useful lifetime).

3F Filippi offers the Constant Light Output (CLO) system, which is able to offset the decrease in luminous flux of the LEDs and avoid the flux/power peak closer to installation by keeping the required lighting values constant over time.The drivers are programmed to supply the LEDs with reduced power over the first few years, gradually increasing the power over time as necessary to offset the reduction in luminous flux of the LEDs.This system, as well as maintaining a constant level of lighting over time, provides energy savings of around 15% in the first few years of the product's lifetime (an average of around 10% over the entire useful lifetime of the product).

Luminaires which can be equipped with CLO technology (with DALI driver)

• L 320 LED• 3F Travetta LED• 3F Linux• 3F Cub LED• 3F LEM• Beta i3F LED

(*) data extrapolated from LM-80 (IES - Illuminating Engineering Society of North America) tests, performed as per standards after 6,000 hours of operation and calculated on the basis of the IESNA TM-21-11 guideline "Projecting Long Term Lumen Maintenance of LED Light Sources"

3F CLOTime passes, the light stays the same

Introduction

LED light sources, unlike traditional lighting, do not tend to suddenly blow at the end of their lifetime; LEDs rather have a gradual reduction of their luminous output overtime before running out after a very long time.The percentage decline of the luminous flux with reference to the useful number of operating hours (50,000 hours) is therefore determined with the parameter “L”. 3F Filippi LEDs, classified as L85 (*), will still supply 85% of their initial luminous flux after 50,000 hours.

Lifetime

Lum

ino

us flu

x

50,000 hours

Page 437: 3F Filippi  "General catalogue 2016"

434434343334 44444

Page 438: 3F Filippi  "General catalogue 2016"

435

Infopoint

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

News and updates available on: www.3f-filippi.com > Infopoint

3F LED TechnologyPage

436 3F LED Technology

438 Photobiological safety

440 Aspects to consider when choosing an LED luminaire

442 Glossary

444 LED luminaire luminous fluxes in Emergency mode

Lighting engineeringPage

446 Lighting engineering

447 Lighting laboratory

448 Assil Quality

449 Lighting engineering calculation software

451 UNI EN 12464-1 - Illumination of indoor workplaces

455 UGR - Unified Glare Rating: glare control

456 Description of louvres

457 Fluorescent lights luminous fluxes

Electrical engineering and ElectronicsPage

460 Electrical engineering and Electronics

460 Electrical engineering laboratory

461 High-quality electronics

462 Electronic wiring characteristics

463 Dimmable electronic wiring characteristics

464 Starter wiring characteristics

465 Emergency wiring characteristics

466 Electrical engineering: Marks and Standards

MechanicsPage

467 Mechanics and Design

468 Mechanics: Marks and Standards

469 Resistance to corrosive substances

Analytical guidePage

470 Standards for correct use of products

471 Analytical guide

Page 439: 3F Filippi  "General catalogue 2016"

436

3F LED TechnologyThe real revolution is simplicity

3F LED TechnologyEasy.

Introduction

The LED is one of the most extraordinary inventions of recent times, and not just in the lighting sector.If you needed any evidence that interest in this technology is huge, just try searching for “LED” in Google – you will get nearly half a billion (496 million) hits! Unfortunately, there is an equal amount of confusion surrounding the topic.

3F Filippi has put more than 60 years of experience in the field to work alongside its designers to create its new LED product line.And the difference is plain to see: in a market full of efficient light sources which is evolving and developing from one day to the next, 3F Filippi has decided to equip its luminaires with sources manufactured using the highest quality components available.

Unfortunately, one of the most common problems for lighting designers is the lack of a common standard to regulate how lighting companies advertise the performance of their products: these "tricks" hinder comprehension and comparability of products.For this reason, we have decided to shed light on the matter with this guide, by explaining LEDs and their most important characteristics simply yet exhaustively.Another step taken by 3F Filippi in this direction is the voluntary certification of our product data through compliance with the Assil Quality project (see specific chapter for more information).

It is important to remember that the original technical features of LED lighting will change according to the operating conditions of each luminaire, and as such, it is incorrect to assume that every LED has the same characteristics in terms of service life, decrease of luminous flux (L) life expectancy (B), etc.

Page 440: 3F Filippi  "General catalogue 2016"

437

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

What is an LED?

LEDs are electronic components which emit light when an electrical current passes through them – the name, indeed, is an acronym for Light Emitting Diode. This is possible thanks to the optical properties of some semiconductors which emit photons when current is passed through them.

When a group of LEDs are installed on a printed circuit, this is known as an LED module.These modules can be of different shapes:

circularlinear squarecompact

3F LED Technology

What are the advantages of 3F LED technology?

Illuminotechnical

• High luminous efficiency LED, up to 200 lm/W

• Immediate on• Control of the light flow, directed light• Absence of IR and UV components

throughout the entire spectrum• Very long lifetime, > 50,000 hours

(professional range)• Lower power than traditional light

sources with equal light output• Increased brightness• Adjustment of luminous flux from as low

as 1%

Environmental

• Mercury free• Lower CO2 emissions thanks to lower

power• Less use of polluting materials in LED

production• Less heat lost to the environment

For the customer

• Reduction of energy costs• Reduction of maintenance costs• Fast return on investment

Comparison chart between luminaires of the same length

Table supposes electricity cost of €0.18 per kWh and total annual operation of 4,000 hours.

Total luminairepower

Total energy consumption Annual saving

2x58W Fluorescent Wiringlow-loss EEI=B2 141W 102 € 0%

2x58W Fluorescent WiringEEI A2 electronic wiring 109W 78 € -24%

2x30W LED wiringballast 68W 49 € -52%

2x22W LED electronicwiring 50W 36 € -65%

Page 441: 3F Filippi  "General catalogue 2016"

438

LEDs: photo-biological safetyIs LED technology safe for health?

Introduction

Among 3F Filippi’s top priorities is the well-being of those who are illuminated by our products. For this reason, we pay a great deal of attention to photo-biological safety, using the best sources with a low impact on human health.

Unfortunately, some less scrupulous manufacturers use low-quality sources during prolonged exposure, emit radiation which is damaging to organs of the human body, such as the eyes and skin. On the amount of radiation emitted from all sources in the range of wavelengths from 200 nm to 3000 nm.A number of Photo-biological Safety Risk Groups (IEC62471) have now been defined, providing a clear indication of the limits of maximum exposure for each group.

Risk classes

In accordance with Paragraph 6.1 of EN 62471: 2010, the risk groups (for blue light) are defined as follows:

• RG 0 (Risk Exempt): The source does not cause any photo-biological risk. Requirement met by any lamp that does not cause a blue light (BL) retinal risk with an exposure time of up to 10,000 s (about 2.8 h).

• RG1 (Low Risk): The source does not cause risk due to normal operating limitations on exposure. Requirement met by any source that exceeds the limits of the Exempt Group but does not cause a blue light (BL) retinal risk with an exposure time of up to 100 s.

• RG 2 (Moderate Risk): The source does not cause a risk due to an instinctive reaction when looking at very bright light sources (or due to a sensation of thermal discomfort.) Requirement met by any source that exceeds the limits of Risk 1 Group but does not cause a blue light (BL) retinal risk with an exposure time of up to 0.25 s (aversion response).

• RG 3 (High Risk): The source can constitute a risk even due to momentary or brief exposure.

• Sources that exceed the limits of Risk Group 2 are included in Risk Group 3.

Page 442: 3F Filippi  "General catalogue 2016"

439

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

LEDs: photo-biological safety

Notes

The current standard EN 60598-1 concerning indoor luminaires indicates that RG0 or RG1 risk groups are acceptable for safety purposes.With the publication of standard EN 60598-1: 2015 (Luminaires - Part 1: General requirements and tests), the acceptable levels for safety purposes were definitively established.In Paragraph 4.24.2 (Blue light retinal risk), the following is indicated:“For luminaires that use light sources from risk group RG0 (unlimited) or RG1 (unlimited), in accordance with IEC/TR 62778, or which have been judged as being finished products ready for use, belonging to risk group RG0 (unlimited) or RG1 (unlimited) , the requirements concerning blue light retinal risk do not apply.”For luminaires that have an ETHR illuminance threshold, evaluated in accordance with IEC/TR 62778, additional requirements are applied for evaluating how far the product is from the threshold between RG2 and RG1. In such cases, although the luminaire cannot be considered to be dangerous, warnings and markings are used to alert the installer or user to the possible risks associated with direct and prolonged viewing of the source.

From a technical perspective, RG0 and RG1 groups cannot be said to be equivalent, or to be both considered as "exempt".The two photo-biological risk groups are in fact distinguished as follows:• RG 0 (Risk Exempt): The source does not cause any photo-biological risk.• RG1 (Low Risk): The source does not cause risk due to normal operating limitations on exposure.

Currently, therefore, there is no regulation that declares the various photo-biological risk groups to be equivalent, or indeed that united them, rendering both exempt.

Exposure to RG1-group luminaires is not considered dangerous under ordinary conditions of use, due to the fact that periods of exposure of over 100 seconds are considered to be "unlikely", although not impossible, as this cannot be predicted in the design phase.Risk group RG0, on the other hand, allows for a longer period of exposure, only warning against periods of over 2.8h: As such, it can be said with greater confidence that it is highly unlikely that a device of this category would be directly viewed for this long.

The demand for RG0 light sources could be considered redundant, but it is not stated anywhere that it is prohibited to request the use of RG0 luminaires, or that these can be considered equivalent to those belonging to the RG1 risk category.As explained above, the RG0 risk group represents a cautionary, optimal class of light source.

A company that exhibits extra caution with regard to the safety of its operators, and decides to install equipment belonging to the risk-exempt RG0 category, could therefore be seen to be excessively conservative, but cannot certainly be criticised for having requested compliance with a parameter that provides greater safety for all involved.

European legislation states that companies, specifically the statutory employer, evaluate and manage risks to workers' health and safety.Among the risks that the employer must evaluate is any photobiological risk deriving from exposure to artificial optical radiation.The reference standard is IEC/EN 62471:2010, which does not define a threshold marking safe from unsafe, but rather defines classification of sources into risk groups.Limitations of use or warnings for the user are contained in the corresponding product standards, while a product marking guide is contained in IEC TR 62471-2:2009.

Page 443: 3F Filippi  "General catalogue 2016"

440

100

85

70

55

96

80

65

5025°C 50°C 75°C 100°C 125°C 150°C

90

75

60

93,2

70°C - 87,7% 86,485,0

82,379,5

72,771,4

65,9

3F LED TechnologyWhat are the aspects to consider when choosing an LED luminaire?

Ideal operating temperature

In order for LED modules to be able to function correctly and ensure a long lifetime (>50,000 h), a limited drop in luminous flux over time (>L85) and high luminous efficiency (>140 lm/W), they must be able to correctly dissipate the heat they generate.The rated data for LEDs applies only if the junction temperature (Tj) is not exceeded. For this reason, at 3F Filippi , we perform a series of thermal and illuminotechnical tests on our LED luminaires, which allow us to achieve the best combination of heat dissipation, luminous flux and rated power.

Reference standards

When studying and designing products, 3F Filippi refers to the most recent specific reference standards:

IEC 62722-2-1Luminaire performance - Part 2-1: Particular requirements for LED luminaires

IEC 62717LED modules for general lighting - Performance requirements

IEC 121The Photometry and Goniophotometry of Luminaires

IEC TR 62778Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires

IEC EN 62471Photo-biological safety of lamps and lamp systems

IEC EN 60598-1Luminaires: General requirements and tests

REGULATION (EU) No. 1194/2012sets out the rules for the application of European Parliament and European Council Directive 2009/125/EC on the specifics of environmentally-friendly design of directional lamps, lamps with light-emitting diodes and other relevant equipment.

Luminous flux and LED performance temperature "tp" (IEC 62717)

The junction temperature (Tj) is the temperature inside the LED, and is useful for indicating the performance temperature (Tp) of the LED, to which reference is made when indicating data relating to the luminaire.As the graph on the left shows, the luminous flux emitted by the LED is linked to the performance temperature while in operation (normally between 60°C and 80°C) and falls very fast as the Tp increases.It is very important to highlight that on the market, there are many manufacturers who declare the luminous flux and useful life with a junction temperature Tj 25°C.

This indication is not correct, because it does not refer to the actual operation of the product.This is clear when you consider that standards require the measurements to be taken at an ambient temperature (Ta) of 25°C – this would mean that the LED does not technically produce any heat - a physically impossible condition.3F Filippi advises you be wary of luminaires which do not provide for correct heat dissipation and recommends that you request information on life expectancy, lifetime and luminous flux from measurements on luminaires which are running and thermally stabilised.The performance of 3F Filippi luminaires is achieved with a room temperature (Ta) of + 25°C as required by the standard IEC 62722-2-1.Conversely, the performance of the LEDs used in 3F Filippi luminaires is achieved with an operating temperature (Tp) of + 60°C to + 80°C, as required by the standard IEC 62717.

Lum

ino

us flu

x %

Junction temperature (°C)

Page 444: 3F Filippi  "General catalogue 2016"

441

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F LED Technology

To increase LED luminaires’ reliability to the maximum, correct thermal dissipation is essential.The temperature is fundamentally important as it influences the luminosity and lifetime of the LED component. 3F Filippi pays great attention to this factor and as a result we develop luminaires which ensure optimum heat dissipation.To the left, a chart that correlates the performance values at different junction temperatures Tj (the operating temperature).

The colour rendering index is an important parameter for the performance of a light source, and evaluates the source's ability to provide an accurate perception of an object's real colours.All LEDs used by 3F Filippi have colour rendering Ra>80, with a typical average value of around 85.Where not already provided for, high colour rendering of Ra>90 can be requested on some products.

LED sources have a light spectrum with greater uniformity across the whole range of colours.Unlike traditional light sources, LEDs do not have interruptions in colour, thus ensuring complete and much-improved vision of the entire colour spectrum - very similar to that seen with natural light.

Thermal management

Colour rendering index (CRI)

Colorimetry and light spectrum

Typical LED light spectrum

Typical light spectrum for traditional sources

LED junction temperature Tj 25°C Tj 60°C

Lumen 1000 950

Efficiency 178 lm/W 169 lm/W

Useful life (@50.000h) L 100 L 85

Life expectancy B 0 B 10

Page 445: 3F Filippi  "General catalogue 2016"

442

10%

20%

30%

40%

50%

60%

70%

80%

90%

100%

3F LED TechnologyGlossary

Luminous fluxThe luminous flux, or light flow, coming from the luminaire represents the quantity of light actually coming out of the device, as its value is defined having already taken into account the luminous efficiency of the luminaire.

Luminous efficiencyThe luminous efficiency of the luminaire is the most useful parameter for the designer for determining the correct product solution to install as it supplies a practical figure between light emitted and total power consumption of the light.Beware of publications listing higher luminous efficiencies based on the theoretical efficiency of the bare LED (reference temperature 25°C) and not its actual performance when installed inside the luminaire.

Relative humidityFor correct maintenance and operation of traditional LED modules over time, the maximum permissible humidity on the component is 85%.For specific applications, UR95 LED modules may be required, guaranteeing correct operation at humidity values of up to 95%.

Lifetime (L value)As previously mentioned, LED sources, unlike traditional lighting, do not tend to suddenly blow at the end of their lifetime; LEDs rather have a gradual reduction of their luminous output overtime before completely running out after a very long time.

The percentage decline of the luminous flux with reference to the useful number of operating hours (usually 50,000 hours) is therefore determined with the parameter “L”.L85: 50000h refers to the fact that the at 50,000 hours of operation, the LED module still provides 85% of the initial luminous flux. We should clarify that this parameter is strongly influenced by the operating conditions of the LED inside the luminaire, and the result is therefore a combination of the quality of the component and good research.

Lifetime

Lum

ino

us flu

x

50,000 hours

Page 446: 3F Filippi  "General catalogue 2016"

443

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

3F LED Technology

LED life expectancy (B value)In LED ratings the value B, followed by a value normally between 10 and 50, indicates the quality of the component used as it defines the percentage of components which, after the normal 50,000 h has elapsed, maintain their rated luminous flux.An LED with declared values of L85/B10=50,000h indicates that on reaching 50,000h, 90% (B10) of the components will have a residual luminous flux of at least 85% of the initial value (L85).If, in the listed characteristics of the LED luminaire, the value B is not indicated, this is considered to be a B50 device - or in other words, 50% of the LEDs do not guarantee the average useful life value indicated.We should clarify that this parameter is strongly influenced by the operating conditions of the LED inside the luminaire, and the result is therefore a combination of the quality of the component and good research.

equal to or more than 85% of the initial flux

less than 85% of the initial flux

LED failure rate (C value)This value indicates the percentage of LEDs which are no longer operational at the end of their lifetime.This value can be indicated with two combinations:• L85/B10/C0: 50,000 hours - indicates that after 50,000 hours, the percentage of LEDs no longer working is 0%.• L85/B10: 50,000 hours - L0/C10: 200,000 hours - indicates that after 200,000 hours, the percentage of LEDs no longer working is

10%.

All LEDs used by 3F Filippi have a failure rate C0 after 50,000 hours. If this value is not indicated, it should be considered C0.

Imperfection rate (F value)On the basis of new requirements for LED modules, the F value, followed by a value normally between 10 and 50, provides a more detailed indication of the quality of the component used as it defines, as well as the percentage of components which do NOT maintain their declared luminous flux characteristics (B), also the failure percentage of the LED component.Imperfection rate “F” = “B” value + “C” valueOn 3F LEDs, as the “C” value is 0, the imperfection rate “F” is the same as the life expectancy (“B” value).

Colour tolerance (MacAdam ellipses)Measurement of the chromatic co-ordinates performed during production of the LED allows selection (known as Binning) to classify the LEDs on the basis of their chromatic differences.This classification, performed via analysis of the so-called MacAdam ellipses (which express colour deviations on the XY axes), allows constant tonality to be obtained among the individual LEDs in the same group and therefore a uniform vision of the light colouration visible on the product.• With the value 1 there is no chromatic difference between the individual LEDs;• With values 2 and 3 the difference is not visible to the human eye and the LEDs are considered of good quality;• With a value of 4, the difference begins to become visible to the human eye;• As the value increases, the difference is increasingly noticeable, and the type of application will dictate whether these differences in

colouration in the LED group used are acceptable or not.3F Filippi provides both the initial value and the value over time. Indeed, due to the consumption of phosphors present in the LEDs, the colour tolerance can change over time.All LEDs used by 3F Filippi always have an initial colour tolerance value of less than 3 MacAdams, and a colour tolerance value over time of less than 4.

Photometric codeThe photometric code consists of 6 digits and indicates the basic parameters of the quality of light, as per the example:

840/349 means 8 4 0 / 3 4 9

Colourrendering

index (CRI) >80

Nominalcolour

temperature 4000 K

Tolerance of the initialcolour

(MacAdam): 3

Tolerance of thecolour over time(MacAdam): 4

Percentage of luminous flux

after 6,000 hours: >90%.

Energy efficiency classThe Directive EU 874/2012 regarding the energy labelling of luminaires sold directly to end users stipulates that for all LED luminaires with integrated light sources, the Energy Efficiency Class (EEC) indicated must be as follows: A / A+ / A++.Indicating a precise energy efficiency class means that the luminaire has been assessed as if it were a lamp/source.As such, all 3F Filippi luminaires come with the best Energy Efficiency Class (EEC): A / A+ / A++ (EU 874/2012)..

Page 447: 3F Filippi  "General catalogue 2016"

444

The following tables show the percentages of luminous flux of LED luminaires in emergency operation (BLF). These fluxes are the minimum guaranteed during rated autonomy as required by EN 60598-2-22, and are therefore the ones to be used in the design stage. The luminous fluxes specified are REAL values, and refer to the OUTPUT of the luminaire.

LED luminaire luminous fluxes and power in Emergency modeData update: February 2016

Code Item Duration RechargeBLFLuminaire (%)

BLF Module (%)

Number of modules inEmergency

Recessed Luminaires

21262 L 323x10W LED EP SP 596x596 1h 24h 11,4 34,3 1EP+2

21263 L 324x10W LED EP SP 596x596 1h 24h 8,6 17,1 2EP+2

21293 L 322x18W LED EP SP 296x1196 1h 24h 9,5 19,0 1EP+1

21589 L 323x10W LED EP LGS 596x596 1h 24h 11,4 34,3 1EP+2

21590 L 324x10W LED EP LGS 596x596 1h 24h 8,6 17,1 2EP+2

21606 L 322x18W LED EP LGS 296x1196 1h 24h 9,5 19,0 1EP+1

28829 L 323x10W LED EP 2S 596x596 1h 24h 11,4 34,3 1EP+2

28847 L 323x10W LED EP 2MG 596x596 1h 24h 11,4 34,3 1EP+2

36576 Lucequadro LED 2000 EP VS 1h 24h 20,0 20,0 1EP

36579 Lucequadro LED 3000 EP VS 1h 24h 14,3 14,3 1EP

36582 Lucequadro LED 2000 EP VOP 1h 24h 20,0 20,0 1EP

36585 Lucequadro LED 3000 EP VOP 1h 24h 14,3 14,3 1EP

36588 Lucequadro LED 2000 EP SOP 1h 24h 20,0 20,0 1EP

36591 Lucequadro LED 3000 EP SOP 1h 24h 14,3 14,3 1EP

37544 Galassia 220 LED AB 2000 EP VOP 1h 24h 20,0 20,0 1EP

37553 Galassia 220 LED AB 2000 EP VS 1h 24h 20,0 20,0 1EP

37580 Galassia 220 LED AB 3000 EP VOP 1h 24h 14,3 14,3 1EP

37589 Galassia 220 LED AB 3000 EP VS 1h 24h 14,3 14,3 1EP

37752 Galassia 220 LED 2000 EP 1h 24h 20,0 20,0 1EP

37761 Galassia 220 LED 2000 EP VT 1h 24h 20,0 20,0 1EP

37770 Galassia 220 LED 2000 EP VOP 1h 24h 20,0 20,0 1EP

37779 Galassia 220 LED 2000 EP VS 1h 24h 20,0 20,0 1EP

37795 Galassia 220 LED 3000 EP 1h 24h 14,3 14,3 1EP

37804 Galassia 220 LED 3000 EP VT 1h 24h 14,3 14,3 1EP

37813 Galassia 220 LED 3000 EP VOP 1h 24h 14,3 14,3 1EP

37822 Galassia 220 LED 3000 EP VS 1h 24h 14,3 14,3 1EP

Waterproof and corrosion-proof

55017 i3F LED 752x30W EP CONC L1565 1h 24h 5,7 11,4 1EP+1

55083 i3F LED 762x30W EP AMPIO VT L1565 1h 24h 5,7 11,4 1EP+1

55145 i3F LED 762x12W EP AMPIO VS L655 1h 24h 14,3 14,3 2EP

55147 i3F LED 762x24W EP AMPIO VS L1265 1h 24h 7,1 14,3 1EP+1

55149 i3F LED 762x30W EP AMPIO VS L1565 1h 24h 5,7 11,4 1EP+1

55607 i3F LED 752x12W EP AMPIO L655 1h 24h 14,3 14,3 2EP

55609 i3F LED 752x24W EP AMPIO L1265 1h 24h 7,1 14,3 1EP+1

55611 i3F LED 752x30W EP AMPIO L1565 1h 24h 5,7 11,4 1EP+1

55677 i3F LED 762x30W EP CONC VT L1565 1h 24h 5,7 11,4 1EP+1

58567 3F Linda LED 1x12W EP LA L660 1h 24h 28,6 28,6 1EP

58569 3F Linda LED 1x6W EP LA L660 1h 24h 57,1 57,1 1EP

58589 3F Linda LED 1x24W EP L1270 1h 24h 14,3 14,3 1EP

58600 3F Linda LED 2x24W EP L1270 1h 24h 7,1 14,3 1EP+1

58601 3F Linda LED 2x24W/865 EP L1270 1h 24h 7,1 14,3 1EP+1

58602 3F Linda LED 2x24W/830 EP L1270 1h 24h 7,1 14,3 1EP+1

58611 3F Linda LED 1x30W EP L1570 1h 24h 11,4 11,4 1EP

58614 3F Linda LED 1x22W EP L1570 1h 24h 15,2 15,2 1EP

58623 3F Linda LED 2x30W EP L1570 1h 24h 5,7 11,4 1EP+1

58624 3F Linda LED 2x30W/865 EP L1570 1h 24h 5,7 11,4 1EP+1

58625 3F Linda LED 2x30W/830 EP L1570 1h 24h 5,7 11,4 1EP+1

58705 3F Linda LED 1x12W ENP LA L660 1h 24h 28,6 28,6 1ENP

58713 3F Linda LED 1x24W ENP L1270 1h 24h 14,3 14,3 1ENP

58625 3F Linda LED 2x30W/830 EP L1570 1h 24h 5,7 11,4 1EP+1

58626 3F Linda LED 2x22W EP L1570 1h 24h 7,6 15,2 1EP+1

58705 3F Linda LED 1x12W ENP LA L660 1h 24h 28,6 28,6 1ENP

58713 3F Linda LED 1x24W ENP L1270 1h 24h 14,3 14,3 1ENP

Page 448: 3F Filippi  "General catalogue 2016"

445

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

LED emergency wiring characteristics

Wiring created with emergency lighting systems with the following characteristics:• Rigid cables, cross section 0.50-0.75-1 mm² (0.75-1 mm² also class II), heat resistant PVC HT 90°C, IEC 20-20.• Protective fuse, same characteristics as starter wiring.• 230V-50/60Hz electronic inverter with protection against excessive battery discharge.• Sealed Nickel-Cadmium or Nickel-Metal Hydride NiMH.• LED to signal presence of power supply and battery charging.• Recharge time 24 hrs.• Running time = 1h minimum under heaviest working conditions.• 3-pole terminal block with incorporated disconnecting fuse for standard power supply live-earthing-neutral (LTN).• 2 pole terminal block for power supply of the emergency recharging line.• Complies with IEC 60598-1, IEC EN 60598-1 (CEI 34-21) and IEC EN 60598-2-22 (CEI 34-22).• Suitable for rooms with temperature from 0°C to +25°C.

On request:• Emergency mode with 3 hours duration, 24 hours recharge, or 1.5 hours duration and 12 hours recharge (according to feasibility),

maintaining the same percentage of the standard luminous flux.• Wiring with intelligent control systems and centralised or local self-diagnostics of emergency lighting.

EP LED permanent emergency lighting

When power is on, EP luminaires operate like normal luminaires; in the event of power failure, the LED module connected to the emergency lighting system switches on or stays on automatically.In EP luminaires with multiple LED modules, you can check how many modules remain on in emergency mode; for example, 1EP+2 indicates that on a 3x (3 LED modules) luminaire, one remains on in an emergency.

ENP non-permanent emergency LED lighting

In ENP luminaires, the LED module switches on only in emergency mode, when there is a power cut.

LED luminaire luminous fluxes and power in Emergency mode

Page 449: 3F Filippi  "General catalogue 2016"

446

Cliente:Agenzia consulenza finanziaria

Redattore:Marco Dalle Donne

3F Filippi S.p.A.Ufficio Progettazione IlluminotecnicaVia del Savena, 28 - 40065Pian di Macina - Pianoro (Bologna / Italy)CF. 01033260371 P.I. IT00529461204Registro imprese di Bologna n. 01033260371REA N. 234613Cap. Sociale Euro 3.000.000 i.v.

Tel: (+39) [email protected]

Data:10/09/2015

3F Filippi 58583 3F Linda LED 1x24W L1270 1x24W 1xLED

Rendimento: 100%Flusso luminoso lampadina: 3593 lmFlusso luminoso lampade: 3593 lmPotenza: 28.0 WRendimento luminoso: 128.3 lm/WTemperatura del colore: 3000 K

Emissione luminosa 1 / CDL polare

160

320

cd/klm η = 100%C0 - C180 C90 - C270

0° 15° 30°

45°

60°

75°

90°

105°105°

90°

75°

60°

45°

30° 15° 0°

ILLUMINOTECNICHE Rendimento luminoso 100%. Flusso luminoso dell'apparecchio 3593 lm. Distribuzione simmetrica controllata. UGR <22 (EN 12464-1). Efficienza apparecchio 128 lm/W. Durata utile (L90/B10): 30.000 h. (Tj 60°C) Durata utile (L85/B10): 50.000 h. (Tj 60°C) Sicurezza fotobiologica conforme al gruppo di rischio esente RG0, norma IEC 62471. MECCANICHE Corpo in policarbonato autoestinguente V2, stampato ad iniezione, colore grigio RAL 7035. Guarnizione di tenuta, ecologica, antinvecchiamento, iniettata. Schermo in policarbonato fotoinciso internamente, autoestinguente V2, stabilizzato agli UV, stampato ad iniezione, con superficie esterna liscia, apertura antivandalica. Riflettore portacablaggio in acciaio zincato a caldo, verniciato a base poliestere bianco, fissato al corpo mediante dispositivi rapidi in acciaio, apertura a cerniera. Scrocchi a scomparsa filo corpo, in acciaio inox, per fissaggio schermo. Dimensioni: 100x1270 mm, altezza 100 mm. Peso 2,32 kg. Grado di protezione IP65. Possibilità di accesso all'interno dell'apparecchio per addetti ai lavori. Apparecchio a temperatura superficiale limitata. - D - Resistenza meccanica IK10 (20 joule). Resistenza al filo incandescente 850°C. Certificato TUV Rheinland-LGA per ambienti alimentari. ELETTRICHE Cablaggio elettronico, 230V-50/60Hz, fattore di potenza >0,90, corrente costante in uscita, classe I. Potenza dell'apparecchio 28 W. ENEC - IMQ. Assil Quality. Temperatura ambiente da -20°C fino a +35°C. SORGENTE Modulo LED lineare da 24W/840, temperatura di colore 4000 K. Resa cromatica Ra >80. Tolleranza del colore (MacAdam): 3. DOTAZIONE Staffe di fissaggio in acciaio inox. APPLICAZIONI Virtualmente in qualsiasi ambiente compatibilmente con le esalazioni/atmosfere che compromettono l'utilizzo delle materie plastiche. Non idonea su superfici soggette a forti vibrazioni, esposte agli agenti atmosferici e su funi o paline.

Progetto 0 10/09/2015

Area 1 / Seminterrato / Seminterrato / 3F Filippi 58583 3F Linda LED 1x24W L1270 1x24W 1xLED / Scheda tecnica apparecchio(1x24W 1xLED)

Tolleranza 10%, tensione 230V-50Hz - ta.25°C, flussi luminosi lampadanominali. 3F Filippi si assume la responsabilità progettuale del presente

progetto sulla base dei dati imputati, declinando ogni responsabilità in casodi inesattezza o incompletezza dei suddetti dati

Pagina 1

3F Filippi supplies its customers with a free lighting engineering design service thanks to the Dialux software which allows them to:

• Consult the photometric characteristics of the luminaire in order to establish the correct application.

• Calculate and check the level of illumination, luminance, as well as the uniformity over horizontal work surfaces (such as work tops and ceiling), vertical work surfaces (such as walls or inclined virtual planes, vertical walls in the room, etc.) and to perform calculation for irregular layouts. With these results, data sheets can be produced with the values shown in point-by-point, isolux, tables, room surfaces, as well as 2D and 3D views of the environment.

Lighting engineeringProfessional lighting engineering design and free consultancy

Product datasheet with indication of the lighting, mechanical and electrical characteristics.

Medium and point-by-point illumination on all surfaces of the environment.

Graphical representations on the surfaces of the environment with the following documents: graph of values, rendering with staggered colours, isolines, tables, etc..

• To make the calculations more precise and create very realistic environments, architectural and furnishing elements can be placed inside the program’s simulation environment.

• The software and the 3F Filippi plug-in are available free to designers, installers and electrical distributors.

• Updates of photometric files and of the lighting engineering software can be downloaded free of charge from the site www.3F-Filippi.it.

• For further information, contact our technical consultants.

Rendering of a calculation environment

Page 450: 3F Filippi  "General catalogue 2016"

447

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineering

3F Filippi is UNI EN ISO 9001 certified for lighting engineering design too.

3F Filippi guarantees photometric data sheets, according to the latest European and international recommendations and standards, thanks to the support of the photometric laboratory, in line with official European laboratories.The photometric tests are performed by procedures in accordance with the UNI EN 13032, UNI 11356 and CIE 121 standards.3F Filippi has the most advanced computer programs for research and optimisation of louvres and flow recuperators in order to achieve maximum efficiency and suitable light distribution for the most widely varying applications.This commitment has been recognised and certified by the CSQ (Italian Company Quality Systems Certification) also for the entire phase of lighting engineering design, thus allowing operation under a Quality Assurance system that also covers interior lighting design in accordance with good engineering practice.

Our ISO 9001 certification, awarded by CSQ (certificate no. 9130.3FFI) can be viewed on our site - www.3F-Filippi.it - in the "Certifications and Guarantees" section.

3F Filippi, as further guarantee of the quality of its products and care to meet the strictest standards, is a sustainer of the most lighting engineering associations in the world:

AIDI (The Italian Illumination Association) carries out incisive and constant scientific, cultural and technical reporting to spread knowledge of lighting issues.

www.aidiluce.it

ASSIL (Italian Lighting Producers' Association) provides technical and normative support for quality and performance improvements of lighting technology on the market, while helping respect people's visual comfort, energy-efficiency requirements and environmental protection.

www.assil.it

IESNA (Illuminating Engineering Society of North America) is the American lighting body which promulgates lighting engineering standards on the American market for designers, producers and professionals in the sector.

www.iesna.org

Page 451: 3F Filippi  "General catalogue 2016"

448

Lighting engineeringProfessional lighting engineering design and free consultancy

3F Filippi pays great attention to lighting designers, and tries to simplify their day-to-day work in any way possible.Indeed, we are convinced that these individuals occupy a central role in the process of improving the quality of lighting, reducing light pollution and wasted energy resources.For this reason, 3F Filippi recommends that lighting projects are carried out by professional, reliable designers who can recommend the best solutions both for you and the environment.

Unfortunately, one of the most common problems for lighting designers is the lack of a common standard to regulate how lighting companies declare the performance of LED luminaires: these "tricks" hinder comprehension and the ability to compare products.

To combat this phenomenon, 3F Filippi has taken an active role in the Assil working group to create the Assil Quality certification, looking to adopt this in the shortest possible time.

The companies involved in this project display great respect for the work of designers and their customers: in recent months the market has been inundated with products of doubtful performance, which are not supported by reliable laboratory measurements.

This self certification, which is voluntary for manufacturers, makes performance data for LED modules and luminaires comparable, reliable and reproducible.

The self-certified declaration is performed via dedicated forms (based on IEC and EN standards), and is designedto provide the market with comparable information to help improve the levels of quality and safety of products placed on the market.

Thanks to Assil Quality Certification, designers can download the general data sheets for products and an official Assil Quality validated and marked certification of the technical data, thus comparable with those of other producers.The Assil Quality sheet contains: essential EN 60598-1 safety data and IEC 62722-2-1 technical performance data.

3F Filippi recommends that lighting designers request "Assil Quality" data certification from other manufacturers as well: this will allow these professionals to gain a clearer idea of the products they are comparing.We believe this is a step towards transparency that all companies in the lighting sector should take.

Those who make comparisons have nothing to hide: bringing something out into the open also means minimising the shadows.This is why today, thanks to Assil Quality, the truthfulness of the data for 3F Filippi luminaires is more out in the open than ever.

Page 452: 3F Filippi  "General catalogue 2016"

449

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

On our website, www.3F-Filippi.it, we provide data sheets, product updates and specifications for our products - all of which are freely available and free of charge.

The Eulumdat files which you can find online can be used in any lighting engineering program, allowing you to continue using the software you prefer (e.g. DIALux, LITESTAR 4D Litecalc, RELUX, AGi32 or 3D Studio Max).

In particular, 3F Filippi has decided to collaborate more closely with the software-houses DIAL and Oxytech to create plug-ins for their lighting engineering calculation programs:

Don't trust in words. Make your own calculations.

Lighting engineering calculation software

For particular requirements or to make a comparison, contact our Sales Network.

Oxytech - LITESTAR 4D Litecalc

DIAL - DIALux

DIAL - DIALux evo

Page 453: 3F Filippi  "General catalogue 2016"

450

Reflection coefficients to use for lighting calculationsReflections in % of painted surfaces and materials (ceiling max 85%; walls max 50%; floor max 30%).

Lighting engineering

White 75 ÷ 85

Light cream 70 ÷ 80

Yellow 60 ÷ 70

Light grey 45 ÷ 65

Pink 45 ÷ 55

Light red 20 ÷ 30

Medium grey 20 ÷ 40

Light blue, green 35 ÷ 55

Dark grey, green, red 10 ÷ 20

Black 03 ÷ 05

Panels in light-coloured mineral fibre 75 ÷ 85

Panels in light-coloured wood 50 ÷ 60

Plaster 70 ÷ 80

White paper 70 ÷ 80

Window panes 06 ÷ 08

Light-coloured curtains with narrow mesh 65 ÷ 70

Light-coloured curtains with wide mesh 35 ÷ 40

Cement, rough concrete 20 ÷ 30

Light-coloured marble 40 ÷ 60

Granite 15 ÷ 20

Maintenance factors to use for lighting calculations

The lighting of a room is the result of the interaction between the lighting devices, the conditions under which they are used, the ageing of the light sources and the environment in which they are installed.The maintenance factor (MF) is the product of these elements:

MF = LLMF x LSF x LMF x RSMF

LLMF - Lamp Lumen Maintenance Factor (represents the reduction of the luminous flux of the source over time).The luminous flux (lumen) of a source in operation decreases gradually with time. This reduction depends on the type of light source and in some cases, on the type of power supply.This factor is determined on the basis of the reduction in luminous flux before performing maintenance (changing lamp or luminaire).

LSF - Lamp Survival Factor (this is the death rate of light sources)After a certain period of time, light sources may cut out. This phenomenon suddenly reduces levels of light in a room. The survival factor is defined in line with the 50% mortality rate of the lamps. In the case of sources that due to their technology, do not die (e.g. LEDs), we must consider this factor as being equal to 1.

LMF - Luminaire Maintenance Factor (this represents the reduction of the luminous flux of the luminaire due to dirt)The dirt and dust present in almost all environments accumulate on the lamp, significantly reducing the amount of light it emits. When these substances accumulate on the surfaces of the luminaire, the amount of light reflected or transmitted from these surfaces is reduced.This factor depends on the environment in which the luminaire is located, as well as on the construction features (e.g. Luminaire with or without a diffuser, indirect lighting with greater dust deposits, protection level, possible chimney effect that removes dust from reflective surfaces) and the foreseen cleaning cycle (every 1-2-3- ...years).

RSMF - Room Surface Maintenance Factor (this represents the reduction of reflections from room surfaces due to dirt)The dirt on surfaces in a room tends to reduce the amount of light these surfaces reflect.Clean surfaces maintain the level of ambient lighting better.This factor varies according to the type of activity and work carried out in the space in question - for example in an office with weekly cleaning and repainting at regular intervals, this maintenance factor will be higher compared to a factory with monthly cleaning intervals and repainting that is carried out only where actually necessary.

Page 454: 3F Filippi  "General catalogue 2016"

451

65°0°

30°

60°

90°

>35° >30°

2M2MG2US2S2SG

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineeringStandards - Indoor lighting

EN 12464-1: 2011Illumination of interior workplaces

This European standard for illumination of interior workplaces replaces the previous one from 2004, with an increase in the importance of illumination to allow workers to perform their visual tasks efficiently and accurately.

Three calculation areas are defined:• Task-area, determination of the visual task area. If this cannot be

determined, the whole surface of the environment is considered.• Immediately surrounding area, at least 50 cm around the task

area• Background area, at least 3 m around the immediately

surrounding area

For good visual communication and recognition of objects, two requirements gain importance:• Cylindrical illuminance• Modelling

Cylindrical illuminance is calculated by the average of the vertical illuminances around the measuring point. The standard requires the following:

Average cylindrical illuminances in interior

Seated persons 1.2m Ez > 50 lx

Standing persons 1.7m Ez > 50 lx

Good visual communication, e.g. offices, meeting rooms, teaching spaces, etc.

Ez > 50 lx

Uniformity Uo ≥ 0,10

Luminaire average luminance limits for radial angles >65°

Screen luminance

High luminancescreen

L > 200 cd.m-2

Medium luminance

screenL ≤ 200 cd.m-2

case Apositive polarity and normal requirements regarding colours and details of information viewed, for example offices, schools etc.

≤ 3000 cd.m-2 ≤ 1500 cd.m-2

case Bnegative polarity with greater requirements regarding colours and details of information viewed, for example for CAD, colour inspections etc.

≤ 1500 cd.m-2 ≤ 1000 cd.m-2

Modelling represents the equilibrium between diffuse and directional light and is calculated as the relationship between the cylindrical and horizontal illuminance at the measurement point. Good modelling is obtained with a value between 0.3 and 0.6.

EN 12464-1: 2011 introduced new limits of average luminance for lighting devices which reflect on computer screens:

Illumination of the immediately surrounding area may be lower than that of the task area but must not be lower than the values given below:

Task area

Immediately surrounding area

Background area

Task area Immediately surrounding area≥ 750 lx 500 lx

500 lx 300 lx

300 lx 200 lx

200 lx 150 lx

150 lx Etask

100 lx Etask

≤ 50 lx Etask

Lighting values are unchanged: the design must include calculation of a maintenance factor that considers both decrease of luminous flux of lamps and level of dust accumulation in the room.

Radial

Glare check for rooms with VDTs

Luminance <200 cd/m

2

<1000 cd/m2

for radialangles >65°

longitudinal

radial

transverse

Transverse Longitudinal

Page 455: 3F Filippi  "General catalogue 2016"

452

Average lighting levels maintained and recommended by EN 12464-1:2011

Lighting engineering

Type of interior, task and activity Em (lx) GlareUGRL

minimum Ra

OFFICES

Writing and data processing 500 19 80

CAD stations 500 19 80

Technical drawing 750 16 80

Conference and meeting rooms 500 19 80

Filing and copying 300 19 80

Archives 200 25 80

Reception 300 22 80

SCHOOLS

Playrooms in nursery schools 300 19 80

Handicraft rooms 500 19 80

Classrooms in secondary schools 300 19 80

Classrooms in evening and adult education schools, art education 500 19 80

Technical drawing rooms 750 16 80

Music practice rooms, language labs 300 19 80

Common rooms and main hall 200 22 80

Preparation rooms and workshops 500 22 80

Computer labs 300 19 80

Vertical illumination of blackboards 500 19 80

Entrances 200 22 80

Teachers’ rooms 300 19 80

Storage rooms for teaching material 100 25 80

Sports facilities, swimming pools (general use) 300 22 80

Canteen 200 22 80

Kitchen 500 22 80

LIBRARIESReading areas 500 19 80

Vertical illumination of shelves 200 19 80

Public service areas 500 19 80

CANTEENS, RESTAURANTS AND SELF-SERVICE

General lighting 200 22 80

Conference rooms 500 19 80

Wardrobe 200 25 80

Buffet, reception, cash desk and porter 300 22 80

Kitchen 500 22 80

Self-service restaurants 200 22 80

Corridors 100 25 80

TRANSIT AREAS AND ROOMS FOR GENERAL USE IN BUILDINGS

Circulation areas and corridors (floor lighting) 100 28 40

Stairs, lifts, escalators 150 25 40

Rest rooms 100 22 80

Infirmary 500 19 80

Technical rooms, control panels 200 25 60

Baths, toilets, wardrobe 200 25 80

Minimum general emergency lighting (EN 1838) min. 0.5 80

Minimum emergency lighting in exit routes (EN 1838) min. 1 80

COMMERCIAL AND/OR EXHIBITION AREASSales areas 300 (1) 22 (1) 80

Cash desks 500 19 80

Packaging desk 500 19 80

Fairs, exhibition halls (general lighting) 300 22 80

Notes:

(1) Lighting and UGR depend on the type of shop.

Page 456: 3F Filippi  "General catalogue 2016"

453

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineeringAverage lighting levels maintained and recommended by EN 12464-1:2011

Type of interior, task and activity Em (lx) GlareUGRL

minimum Ra

INDUSTRIAL AND ARTISANAL ENVIRONMENTS

Agriculture - Loading and handling of goods, moving equipment 200 25 80

- Livestock buildings 50 40

- Preparation of fodder, dairies, tool washing, delivery rooms 200 25 80

Chemical, plastic, rubber industry - Workplaces with continuous presence of personnel 300 25 80

- Rooms for precision measurement, laboratories 500 19 80

- Pharmaceutical production, tyres 500 22 80

- Colour inspection 1000 16 90

- Cutting, finishing, inspection 750 19 80

Food industries - Beer breweries, jam/chocolate/sugar production plants 200 25 80

- Product selection and washing, packaging 300 25 80

- Work zones in slaughterhouses, dairies, mills 500 25 80

- Inspection of glass and bottles, product check 500 22 80

- Food production, kitchen work, cigarette manufacture 500 22 80

- Laboratories 500 19 80

- Colour inspection 1000 16 90

Metal working and transformation - Rough and medium machining 300 22 60

- Fine machining 500 19 60

- Marking off, inspection 750 19 60

- Manufacture of tools and cutting equipment 750 19 60

- Rough assembly 200 25 80

- Medium assembly 300 25 80

- Fine assembly 500 22 80

- Precision assembly 750 19 80

Power plants - Fuel supply facilities 50 20

- Boiler rooms 100 28 40

- Machine shop 200 25 80

- Pump rooms, condenser rooms, switching systems 200 25 60

- Control stations 500 16 80

- Outside control devices 20 20

Textile production and processing - Workplace in vicinity of baths 200 25 60

- Washing, ironing, spinning 300 22 80

- Spinning, twining, spooling 500 22 80

- Finishing, dying, weaving 500 22 80

- Sewing, fine-gauge knitting, mending 750 22 80

- Colour inspection, quality control 1000 16 90

Automotive - Body and assembly 500 22 80

- Painting, polishing booth 750 22 80

- Painting: retouching, inspection 1000 19 90

- Upholstery, final inspection 1000 19 80

Woodworking and wood processing - Automatic processing 50 28 40

- Steaming beds 150 28 40

- Saw frame 300 25 60

- Bench work, assembly 300 25 80

- Smoothing, painting 750 22 80

- Machine work 500 19 80

- Wood selection, inlay 750 22 90

- Quality control, inspection 1000 19 90

WAREHOUSES AND COLD STORAGE ROOMS

Storage areas 100 25 60

Handling, packing, shipping areas 300 25 60

Warehouses with racking – corridor without personnel (lighting at floor) 20 40

Warehouses with racking – corridor with personnel (lighting at floor) 150 22 60

Control stations 150 22 60

Page 457: 3F Filippi  "General catalogue 2016"

454

Average lighting levels maintained and recommended by EN 12464-1:2011

Lighting engineering

Type of interior, task and activity Em (lx) GlareUGRL

minimum Ra

HEALTHCARE STRUCTURES

Recovery rooms (general lighting, at floor) 100 19 80

Recovery rooms (lighting for reading and simple examination) 300 19 80

Corridors (day) 200 22 80

Corridors (night) 50 22 80

Public rooms 200 22 80

Diagnosis rooms (general lighting) 500 19 90

Diagnosis rooms (examination and treatment) 1000 19 90

Pre-operating rooms 500 19 90

Operating rooms 1000 19 90

Laboratory, pharmacy (general lighting) 500 19 80

Massage, radiotherapy, endoscopy, simple examinations 300 19 80

Examinations and intensive care 1000 19 90

Treatment, dialysis, plaster rooms 500 19 80

Dentists (general lighting) 500 19 90

Sterilisation and disinfection rooms 300 22 80

INDOOR SPORTS FACILITIES (2) - Standard EN 12193

Physical exercise rooms 300

Track and field 200-300-500

Lawn bowling 200-300-500

Swimming pool 200-300-500

Wrestling, weight-lifting, judo 300-500

Basketball, volleyball 300-500-750

Boxing 300-500

Tennis 200-300-750

Table tennis 300-500-700

Target-shooting (spring-board - target) 300-500

Archery 150-300-400

INDOOR PARKING

Lanes and parking areas (floor lighting) 75 25 20

Entrance/exit ramps (day) (lighting at floor) 300 25 20

Entrance/exit ramps (night) (lighting at floor) 75 25 20

Ticket office 300 19 80

OUTDOOR AREAS (CIE 129)Parking areas for shops, schools, condominiums 5

Very rough work, loading and unloading 20

Rough work, transport and storage 50

Pedestrian walkways 5

KEYEm Average lighting level, generally referring to a height of 0.85 m from the floor for work zones and at floor level for transit zones.

UGRL Unified glare rating in room based on characteristics of observation and lay-out of luminaires, developed by IEC and required by European standard EN 12464-1 (see next page).

Ra Minimum colour rendering index of lamps (see p.409, 410 and 411).

Notes: (2) Indoor sports facilities provide for 3 levels of lighting based on their use, specifically: Non-competitive sports, Competitive sports at local level, Competitive sports at national and international level.

Page 458: 3F Filippi  "General catalogue 2016"

455

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineeringU.G.R. - Unified Glare RatingUGR is a unified international index developed by CIE (Commission Internationale de l'Eclairage) in publication 117 of 1995, to evaluate direct glare in every specific application based on the position of luminaires, room characteristics (dimensions, reflections), and on the observation point of workers.

UGR reference values on CIE tables range between 10 and 30 in steps of 3 units (10, 13, 16, 19, 22, 25 and 28) and apply to both directions of view (transverse and longitudinal) to the luminaire: the lower the value, the less direct glare.

European standard EN 12464-1 for the lighting of indoor workplaces requires a UGR value for every application.Respecting the UGR value in workplaces with VDTs is a necessary but not sufficient condition because the average luminance requirement for luminaires (1000-3000 cd/m

2) is still in effect (see

the tables on the previous pages for specific values).

UGR tables are supplied for each luminaire, but are valid only for normal workplaces.

Example of calculation office with 4x18 2MG luminaireEN 12464-1 requires a UGR value of ≤19 for this application.

Data for room and installation:

• Room height: 3.2 m• Height from worker’s eye to luminaire H: 3.2-1.2= 2 m• Transverse distance 8.0 m ÷ 2 m = 4H• Longitudinal distance 16.0 m ÷ 2 m = 8H• Reflection index: Ceiling 70%; Walls 50%; Floor 20%.

Calculations• Transverse UGR: 15.2 Value in direction of observation

transverse to luminaires.• Longitudinal UGR: 15.6 Value in direction of observation

longitudinal to luminaires.

UGR Table - luminaire 4x18 2MG

Work surface and keyboard.Direct and reflected on VDT.

Glare

Ceiling 70 70 50 50 30 70 70 50 50 30

Walls 50 30 50 30 30 50 30 50 30 30

Floor 20 20 20 20 20 20 20 20 20 20

Environment Transverse viewof luminaire

Longitudinal viewof luminaireX Y

2H 2H 15.6 16.6 15.8 16.8 17.1 16.1 17.2 16.4 17.4 17.6

3H 15.4 16.4 15.7 16.6 16.9 16.0 16.9 16.3 17.2 17.4

4H 15.3 16.2 15.7 16.5 16.8 15.9 16.8 16.2 17.0 17.3

6H 15.3 16.1 15.6 16.4 16.7 15.8 16.6 16.1 16.9 17.2

8H 15.2 16.0 15.6 16.3 16.6 15.8 16.6 16.1 16.8 17.2

12H 15.2 16.0 15.6 16.3 16.6 15.7 16.5 16.1 16.8 17.1

4H 2H 15.5 16.4 15.8 16.7 16.9 15.9 16.8 16.3 17.1 17.4

3H 15.4 16.1 15.7 16.4 16.7 15.8 16.5 16.2 16.9 17.2

4H 15.3 15.9 15.7 16.3 16.6 15.7 16.4 16.1 16.7 17.1

6H 15.2 15.8 15.6 16.1 16.5 15.6 16.2 16.0 16.6 17.0

8H 15.2 15.7 15.6 16.1 16.5 15.6 16.1 16.0 16.5 16.9

12H 15.1 15.6 15.6 16.0 16.4 15.6 16.0 16.0 16.4 16.9

8H 4H 15.2 15.7 15.6 16.1 16.5 15.6 16.1 16.0 16.5 16.9

6H 15.1 15.5 15.5 15.9 16.4 15.5 16.0 16.0 16.4 16.8

8H 15.0 15.4 15.5 15.9 16.3 15.5 15.9 15.9 16.3 16.8

12H 15.0 15.3 15.5 15.8 16.3 15.4 15.8 15.9 16.2 16.7

12H 4H 15.1 15.6 15.6 16.0 16.4 15.6 16.0 16.0 16.4 16.9

6H 15.0 15.4 15.5 15.9 16.3 15.5 15.9 15.9 16.3 16.8

8H 15.0 15.3 15.5 15.8 16.3 15.4 15.8 15.9 16.2 16.7

Page 459: 3F Filippi  "General catalogue 2016"

456

Description of louvresAll of our louvres are composed of parabolic longitudinal and transverse elements. The transverse elements (blades) are completely closed at the top to provide:• Higher efficiency (+10%)• Parabolic uniformity without deformation• A much stronger and sturdier louvre

The aluminium louvres are very thick, which makes them extremely strong and non-deforming even after many maintenance procedures.No tools are needed to open the louvre, which remains suspended with steel springs. Earthing is maintained by the springs or an earthing wired during maintenance.

Lighting engineering

Types of louvres

Low luminance

With special diffuser, in rooms with VDTsand CAD, generic sales and business offices, school rooms.Luminance <200-1000 cd/m2 for radial angles >65°. 2M Specular aluminium 2MG Specular aluminium, high efficiency 2US Semi-polished aluminium 2S Semi-specular aluminium

Decorative/Business

Highly aesthetic, in public spaces,sales and business offices, showrooms. 3AO Matt silver aluminium COM Specular aluminium, high efficiency for longitudinal elements; white aluminium for transverse blades

Louvres 2M 2MG

Material aluminium aluminium

Surface specular specular

Total reflection 87% 95%

Efficiency R>65% R>70%

Luminance <200 -1000 cd/m2

for radial angles >65° >65°

Matching of louvre to colour

of furnishing visible visible

Contrasts of luminous flux on louvre\tab present

present present

Iridescent effect light absent

Delicacy of louvre to touch notable notable

Deposits of dust visible visible

Louvres 2US 2S

Material aluminium aluminium

Surface semi-glossy semi-specular

Total reflection 85% 87%

Efficiency R>62% R>65%

Luminance <200 -1000 cd/m2

for radial angles >65° >65°

Matching of louvre to colour

of furnishing invisible invisible

Contrasts of luminous flux on louvre\tab present

limited absent

Iridescent effect absent absent

Delicacy of louvre to touch limited limited

Deposits of dust invisible invisible

Louvres 3AO

Material aluminium

Surface satin

Total reflection 78%

Efficiency R>60%

Visual effect soft

Delicacy of louvre to touch limited

Deposits of dust invisible

Page 460: 3F Filippi  "General catalogue 2016"

457

22 40 55 60

24 39 54 4980

14 21 28 35

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineeringFluorescent lamps and caps

Power[W]

Length [mm] Cap

Flux (25°C)[lm]

Colourtemperature

[K]

Colour rendering Systemefficiency [lm/W] Luminance

[cd/cm2]

Average life hours

Ra group

Ra index HF HF

Linear fluorescent electronic T5 lamps Ø16mm, high-efficiency

14 549 G5 1200 27-30-35-4000 1B 80-90 75 1.7 24,000

1100 6500 1B 80-90 69 1.6 24,000

1080 8000 1B 80-90 66 24,000

21 849 G5 1900 27-30-35-4000 1B 80-90 79 1.7 24,000

1750 6500 1B 80-90 73 1.6 24,000

1700 8000 1B 80-90 71 24,000

28 1149 G5 2600 27-30-35-4000 1B 89-90 87 1.7 24,000

2500 5000 1B 80-90 80 1.6 24,000

2400 6500 1B 80-90 80 1.6 24,000

2350 8000 1B 80-90 78 24,000

35 1449 G5 3300 27-30-35-4000 1B 80-90 87 1.7 24,000

3050 6500 1B 80-90 80 1.6 24,000

3000 8000 1B 80-90 79 24,000

Linear fluorescent electronic T5 lamps Ø16mm, high-output

24 549 G5 1750 27-30-35-4000 1B 80-90 65 2.5 24,000

1650 5000 1B 80-90 61 2.4 24,000

1600 6500 1B 80-90 59 2.4 24,000

1550 8000 1B 80-90 57 24,000

1300 4000 1A >90 48 1.7 24,000

1400 50-6500 1A >90 52 1.8 24,000

39 849 G5 3100 27-30-35-4000 1B 80-90 72 2.8 24,000

2850 6500 1B 80-90 66 2.7 24,000

54 1149 G5 4450 27-30-35-4000 1B 80-90 73 2.9 24,000

4100 6500 1B 80-90 67 2.8 24,000

4000 8000 1B 80-90 66 24,000

3800 4000 1A >90 57 2.0 24,000

3800 6500 1A >90 62 2.2 24,000

49 1449 G5 4300 27-30-35-4000 1B 80-90 80 2.0 24,000

4100 6500 1B 80-90 76 1.9 24,000

4050 8000 1B 80-90 75 24,000

3500 4000 1A >90 63 1.6 24,000

3450 50-6500 1A >90 69 1.7 24,000

80 1449 G5 6150 27-30-35-4000 1B 80-90 71 2.9 24,000

5700 6500 1B 80-90 66 2.7 24,000

5550 8000 1B 80-90 64 24,000

Linear fluorescent electronic T5 lamps Ø16mm, high-output, long lasting

54 1149 G5 4450 30-4000 1B 80-90 73 2.9 45-70,000

49 1449 G5 4300 30-4000 1B 80-90 80 2.0 45-70,000

80 1449 G5 6150 30-4000 1B 80-90 71 2.9 45-70,000

Round fluorescent electronic T5 lamps Ø16mm

22 Ø225 2GX13 1800 27-30-4000 1B 80-90 72 2.0 12,000

1710 6500 1B 80-90 68 1.9 12,000

40 Ø300 2GX13 3300 27-30-4000 1B 80-90 73 2.6 12,000

3000 6500 1B 80-90 68 2.4 12,000

55 Ø300 2GX13 4200 27-30-4000 1B 80-90 70 3.6 12,000

3800 6500 1B 80-90 63 3.2 12,000

60 Ø380 2GX13 5000 30-4000 1B 80-90 77 3.8 12,000

Page 461: 3F Filippi  "General catalogue 2016"

458

32 4022

36 5818

Fluorescent lamps and caps

Lighting engineering

Fluorescent lamps commonly used for indoor lighting. See EN 12464-1 for selection of colour rendering index of lamp based on visual task.The above values are taken from the catalogues published by lamp manufacturers and are subject to change; for specific lamp values, please see the relevant manufacturer catalogues.

The average life of lamps is assessed on the basis of lamps with electronic wiring with warm-start ballasts.

Colour temperature groups:below 3300K Warm light3300K to 5300K Neutral lightabove 5300K Cold light

Power[W]

Length [mm] Cap

Flux (25°C)[lm]

Colourtemperature

[K]

Colour rendering Systemefficiency [lm/W] Luminance

[cd/cm2]

Average life hours

Ra group

Ra index Starter HF Starter HF

Linear fluorescent T8 lamps Ø26mm

18 590 G13 1350 27-30-35-4000 1B 80-90 52 68 1,0 10.000 20.000

1300 6500 1B 80-90 50 66 0,95 10.000 20.000

1300 8000 1B 80-90 50 66 10.000 20.000

1100 3000 1A >90 42 56 0,9 10.000 20.000

1200 4000 1A >90 46 61 0,9 10.000 20.000

1150 54-6500 1A >90 44 58 10.000 20.000

1200 4000 2B 60-70 46 10.000

1050 6500 2A 70-80 40 10.000

36 1200 G13 3350 27-30-35-4000 1B 80-90 78 89 1,25 10.000 20.000

3250 6500 1B 80-90 76 87 1,2 10.000 20.000

2900 8000 1B 80-90 67 77 10.000 20.000

2700 3000 1A >90 63 72 10.000 20.000

2900 4000 1A >90 67 77 10.000 20.000

2850 54-6000 1A >90 66 76 10.000 20.000

2850 4000 2B 60-70 66 10.000

2500 6500 2A 70-80 58 10.000

58 1500 G13 5200 2700-30-35-4000 1B 80-90 78 91 1,5 10.000 20.000

5000 6500 1B 80-90 75 87 1,5 10.000 20.000

4900 8000 1B 80-90 73 86 10.000 20.000

4350 3000 1A >90 65 76 10.000 20.000

4600 4000 1A >90 69 80 10.000 20.000

4550 54-6000 1A >90 68 79 10.000 20.000

4600 4000 2B 60-70 69 10.000

4000 6500 2A 70-80 60 10.000

Linear fluorescent T8 lamps Ø26mm, long lasting Linear fluorescent T8 lamps Ø26mm

18 590 G13 1350 30-4000 1B 80-90 52 68 1,0 47.000

1250 6500 1B 80-90 48 63 0,95 47.000

1350 30-4000 1B 80-90 52 68 1,0 55.000

1250 6500 1B 80-90 48 63 0,95 55.000

36 1200 G13 3250 30-4000 1B 80-90 76 87 1,25 47.000

3150 6500 1B 80-90 73 84 1,2 47.000

3350 30-4000 1B 80-90 78 89 1,25 55.000

3200 6500 1B 80-90 74 85 1,2 55.000

58 1500 G13 5150 30-4000 1B 80-90 77 90 1,5 47.000

5000 6500 1B 80-90 75 87 1,45 47.000

5200 30-4000 1B 80-90 78 91 1,5 55.000

5000 6500 1B 80-90 75 87 1,5 55.000

Round fluorescent T8 lamps Ø26mm

22 Ø216 G10q 1250 27-4000 1B 80-90 45 0,70 10.000

1100 4000 2B 60-70 39 0,60 10.000

1000 6500 2A 70-80 34 0,50 10.000

32 Ø305 G10q 2100 27-4000 1B 80-90 55 0,75 10.000

1900 4000 2B 60-70 50 0,68 10.000

1600 6500 2A 70-80 42 0,60 10.000

40 Ø406 G10q 2800 27-4000 1B 80-90 61 0,80 10.000

2450 4000 2B 69-70 53 0,70 10.000

2200 6500 2A 70-80 48 0,65 10.000

Page 462: 3F Filippi  "General catalogue 2016"

459

C

C

CT

CD

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Lighting engineeringFluorescent lamps and caps

Power[W]

Length [mm] Cap

Flux (25°C)[lm]

Colourtemperature

[K]

Colour rendering Systemefficiency [lm/W] Luminance

[cd/cm2]

Average life hours

Ra group

Ra index Starter HF Starter HF

Fluorescent compact lamps

11C 214 G23 900 27-30-4000 1B 80-90 60 2,7 8.000 20.000

850 6500 1B 80-90 57 2,7 8.000 20.000

2G7 900 27-30-4000 1B 80-90 60 2,7 10-13.000

18C 217 2G11 1200 27-30-4000 1B 80-90 50 58 2,1 8.000 10-13.000

950 30-40-5400 1A 90-100 31 36 2,1 8.000 10-13.000

24C 317 2G11 1800 27-30-4000 1B 80-90 56 66 2,1 8.000 10-13.000

1500 30-40-5400 1A 90-100 38 44 2,1 8.000 10-13.000

36C 411 2G11 2900 27-30-4000 1B 80-90 67 80 2,8 8.000 10-13.000

2600 8000 1B 80-90 60 71 8.000 10-13.000

2350 30-40-5400 1A 90-100 44 52 2,8 8.000 10-13.000

40C 533 2G11 3500 27-30-4000 1B 80-90 80 2,3 10-20.000

3325 6500 1B 80-90 76 10-20.000

3150 8000 1B 80-90 68 10-20.000

2950 5400 1A 90-100 50 10-20.000

55C 533 2G11 4800 27-30-35-4000 1B 80-90 80 3,2 10-20.000

4800 6500 1B 80-90 75 10-20.000

4320 8000 1B 80-90 68 10-20.000

4000 30-40-5400 1A 90-100 50 3,2 10-20.000

80C 568 2G11 6000 27-30-35-4000 1B 80-90 69 3,7 10-20.000

5850 8000 1B 80-90 65 10-20.000

13CD 115 G24d-1 900 27-30-40-6500 1B 80-90 56 4,0 8.000

G24q-1 900 27-30-4000 1B 80-90 69 4,0 10-13.000

18CD 130 G24d-2 1200 27-30-35-40-6500 1B 80-90 50 4,5 8.000

G24q-2 1200 27-30-4000 1B 80-90 60 4,5 10-13.000

26CD 149 G24d-3 1800 27-30-35-40-6500 1B 80-90 56 6,0 8.000

G24q-3 1800 27-30-35-40-6500 1B 80-90 67 6,0 10-13.000

Fluorescent compact lamps, long lasting

36C 411 2G11 2900 30-4000 1B 80-90 80 2,8 36.000

55C 533 2G11 4800 30-4000 1B 80-90 80 3,2 36.000

Fluorescent compact amalgam lamps

40C 533 2G11 3500 4000 1B 80-90 80 2,3 12.000

55C 533 2G11 4800 4000 1B 80-90 80 3,2 12.000

80C 568 2G11 6000 4000 1B 80-90 69 3,7 12.000

18CT 100 GX24d-2 1200 27-30-4000 1B 80-90 50 4,5 8.000

GX24q-2 1200 27-30-4000 1B 80-90 60 4,5 10-13.000

26CT 115 GX24d-3 1800 27-30-4000 1B 80-90 56 6,0 8.000

GX24q-3 1800 27-30-4000 1B 80-90 67 6,0 10-13.000

32CT 131 GX24q-3 2400 27-30-4000 1B 80-90 69 6,5 10-13.000

42CT 152 GX24q-4 3200 27-30-4000 1B 80-90 70 7,0 10-13.000

Fluorescent compact amalgam lamps, long lasting

32CT 131 GX24q-3 2400 30-4000 1B 80-90 69 6,5 33.000

42CT 152 GX24q-4 3200 30-4000 1B 80-90 70 7,0 33.000

57CT 181 GX24q-5 4300 30-4000 1B 80-90 69 7,0 33.000

G••d-• cablaggi magnetici con starter integrato nella lampada.

G••q-• cablaggi elettronici, elettronici in emergenza, magnetici in emergenza, magnetici con starter non integrato nella lampada.

Page 463: 3F Filippi  "General catalogue 2016"

460

Laboratory testing3F Filippi has an internal IMQ (Italian Quality Mark)-certified test laboratory to guarantee its Customers solid products certified to the toughest standards; this lab is able to perform the following tests:

Electrical engineering and Electronics

To carry out these tests, 3F Filippi uses IMQ-approved equipment and facilities that have been granted the IMQ-078/CTF2-A certificate (this can be downloaded from our website at www.3F-Filippi.it).

All this allows us to perform product certification tests autonomously, speeding up product development significantly, all to the customer's advantage and guaranteeing the safety, quality and duration of products.

Moreover, all our products are manufactured in compliance with the current national IEC 34-21, European EN 60598-1 and international IEC 60598-1 standards.

Temperature test

Serves to measure the temperatures reached by the electrical or electronic components or the thermal limits of the materials used for the luminaires.

Resistance to salt spray test

This is an accelerated corrosion test to provide a qualitative assessment of the corrosion resistance of a material or the corrosion protection provided by a coating.

Liquid-proof test

Serves to determine the level of protection of a product against the entry of liquids into the product body. The results obtained determine the IP rating of a product.

Dust-proof test

Serves to determine the level of protection of a product against the entry of solid bodies. The results obtained determine the IP rating of a product.

Page 464: 3F Filippi  "General catalogue 2016"

461

0

4

8

12

16

20

24

0,15/0,05 0,45/0,15 2,45/0,15 11,30/0,30

100%

0

0 15,000 25,000 50,000 75,000

90%80%

60%

40%

20%

115

100

80

0 210V 230V 250V

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Electrical engineering and ElectronicsLighting engineering requirements of luminaires are satisfied by quality electronicsUnfortunately, cheap electronic ballasts are available on the market.

But these consume more energy, give shorter lamp life, shorter

ballast life, irregular output power, etc.

Their main differences compared to quality electronics are described below:

Quality HF: lower power consumption

Quality HF: energy efficiency index EEI= A2 BAT

Cheap HF: energy efficiency index EEI= A3

Quality HF: longer lamp life

On/off cycles (hours)

Lam

p a

vera

ge life

(x1

00

0)

Quality HF: longer ballast life Quality HF: constant (=lamp flow) output power

Example of correct design of a luminaire with electronic fluorescent lamps and ballast unit to safeguard efficiency and life.

3F Filippi is a leader in the research and manufacture of luminaires specially designed for electronic

fluorescent lamps and wiring.

Oversized housings and gear trays, the choice of materials such as aluminium and steel for better heat dissipation, and careful positioning of components allow electronic ballasts to work at temperatures well below allowed limits and electronic fluorescent lamps to work under optimum emission conditions.

3F Filippi uses only top quality leading-brand electronic ballasts

3F Cub

3F Dodeca

Electronic ballasts

Large lamp compartment for maximum light emission

Large lamp compartment for maximum light emission

Large wiring compartmenttemperature

Electronicballast

Aluminium body for improved heat dissipation

Separate wiring compartment to limit temperature

Statistic life [HRS] Mains voltage

quality HF

quality HF

low cost HF

low cost HF

IECcycle

HF cold start

HF warm start

HF in o

pera

tio

n [%

]

Ab

so

rbed

po

wer

Psys [%

]

Page 465: 3F Filippi  "General catalogue 2016"

462

0

4

8

12

16

20

24

0,15/0,05 0,45/0,15 2,45/0,15 11,30/0,30

HF acc. immediata

HF acc. a caldo

ciclo IEC

MultiWatt

Wirings are created with finest quality, high frequency, lamp warm start electronic ballasts with energy efficiency index EEI = A2 and/or EEI = A2 BAT (Best Available Technology). Electronic ballast integrates the functions of current limiter, starter, and power factor corrector.Operation of the fluorescent lamp, powered at highfrequency, provides the following advantages for the end user:• 20-30% energy saving.• 50% longer lamp life.• High quality light without flickering and strobe effects.• Power factor >0.95 (check values on product cards).• Constant output power.• Automatic switch-off of consumed lamps.• Lower maintenance.• Lower temperature in luminaires during operation. • No hum.

Technical specifications:• Power supply requirement 230V/50-60Hz with tolerance+/- 10% of

line voltage.• Operating frequency >25 KHz in all power ranges.• Possibility of DC operation.• Leakage current to earth less than 0.5 mA, facilitating coordination

of differential switches.• Suitable for rooms with temperatures from -15°C to +30°C.• For use at low temperatures (0°C to -30°C), it is recommended

Surge Protection Devices are used on the power supply line and any causes of undervoltages are eliminated.

For use in tough conditions, for instance with the presence of corrosive chemicals, extreme temperatures, high humidity (e.g. composting systems, cold stores, mushroom beds, greenhouses, saunas etc.), contact our Technical department.

Type of electronic ballast:• Electronic ballasts with cold start of lamp. The lamp switches

on immediately when ballast power is applied (< 0.5 sec). These ballasts are suitable for applications with a maximum of 3 daily switch-ons.

• Electronic ballasts with warm start of lamp.• The lamp switches on after 1-2 seconds (pre-heat time), and

therefore start-up and best operation of the lamp are guaranteed even in applications with many daily switch-ons.

Important: considering the same number of on/off cycles, the warm start ballast always ensures longer lamp life than the cold start ballast. (See chart below for T5 and T8 linear fluorescent lamps).All 3F Filippi luminaires are fitted with warm-start electronic ballasts and provide constant output power.

Note: fluorescent lamps with electronic ballasts also have emissions in the infra-red range which can interfere with IR-based systems; to prevent interference or malfunction, such systems must operate with a higher carrier frequency.

Electrical engineering and electronicsFluorescent electronic wiring

Luminaires

Maximumpower (W)

lamp+ballastsystem

Luminaires

Maximumpower (W)

lamp + ballast system

T8 1x18 19 Round T5

1x36 36

1x58 55

2x18 35

2x36 71 1x22 T5-R 25

2x58 109 1x40 T5-R 42

3x18 53 1x55 T5-R 60

3x18* 55 1x60 T5-R 65

4x18 70

4x18* 74

4x36 142

4x58 218

T5 1x14 T5 16 Compact

1x24 T5 25 2x24C 48

1x28 T5 31 4x24C 96

1x35 T5 38 1x40C 45

1x39 T5 41 1x55C 60

1x49 T5 53 2x36C 70

1x54 T5 58 2x40C 89

1x80 T5 86 2x55C 118

2x14 T5 31 3x40C 134

2x24 T5 49 3x55C 178

2x28 T5 60 4x40C 178

2x35 T5 76 4x55C 236

2x49 T5 106 6x55C 354

2x54 T5 114 2x80C 173

2x80 T5 170 1x18CD-CT 19

3x14 T5 48 1x26CD-CT 26

3x14* T5 48 1x32CT 34

3x24 T5 75 1x42CT 44

4x14 T5 62 2x18CD-CT 37

4x14* T5 62 2x26CD-CT 53

4x24 T5 98 2x32CT 69

4x35 T5 152 2x42CT 91

4x54 T5 228

4x49 T5 212

4x80 T5 340

6x49 T5 318

6x54 T5 342

MultiWatt electronic wiringMultiWatt electronic ballasts for T5 linear lamps and compact lamps allow different power lamps to be used in the same luminaire. This offers maximum flexibility when changing activities and/or visual tasks in the rooms: the new lighting required is obtained simply by changing the lamp. It is possible to personalise workplace lighting and optimise light levels based on the visual needs of each worker.The luminaires supplied with these ballasts as standard are: Barraluce L, Barraluce P, Fly2, 3F Travetta DI, 3F Travetta, Mira Parete DE, P200 T5, L 580 T5 MultiWatt, L590 T5 MultiWatt, 3F Linda MultiWatt.

On/off cycles (hours)

Lam

p a

vera

ge life

(x1000)

Page 466: 3F Filippi  "General catalogue 2016"

463

140

120

100

80

60

40

20

0

55

141

109

100

80

60

40

20

0

39

100

77

0

10

20

30

40

50

60

70

80

90

100

1 3 5 10 20 30 40 50 60 70 80 90 100

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Electrical engineering and electronicsAdjustable fluorescent electronic wiringDimmable electronic ballasts permit to design “dynamic light systems” in which the light level can be adapted to the visual task and/or to variation of natural light entering from the outside.In addition to the advantages of electronic wiring, dimmableelectronic ballasts (EEI = A1 BAT) with lamp warm start allow the light level to be adjusted over an extremely wide range (1% to 100%), optimising the lighting system for energy saving and visual comfort.

The lamps are dimmed by a control signal carried by wires directly to the ballast from devices such as potentiometers, buttons, light and/or presence sensors, used individually or managed by control units.

Dimmable electronic wiring is done with:• electronic ballasts with 1-10V interface, with dimming

by means of an analogue signal ranging from 10V DC (maximum light) to 1V (minimum light)

• electronic ballasts with DALI interface, with digital dimming according to the new standard Digital Addressable Lighting Interface protocol.

On request, all dimmable wiring systems can be done with electronic ballasts with DALI interface.With appropriate interfaces, dimmable electronic wiringalso allows creation of appropriate lighting systems for creating lighting systems suitable for applications in systems managed by intelligent (bus) systems.For further information please contact our Technical Offices.Important: run new lamps for at least 100 hours at maximum luminosity (100%) to prevent malfunctions at start and to avoid a reduction in the lamp lifetime.Dimmable electronic wiring is the best solution for energy-efficientand high light-efficient systems,letting users adapt lighting to their precise needs, i.e., the right light without waste.Suitable for rooms with temperature from +5°C (+10°C/15°C for C, CD, CT compact or T5 linear fluorescent lamps) to +30°C.

Cost comparison of the various types of fluorescent wiringCommercial EnvironmentFor this type of environment, a 2x58W luminaire running for 4000 hours per year has been considered.

The table below shows the yearly energy consumption persingle luminaire. To obtain the consumption ofthe whole system, just multiply by the totalnumber of luminaires installed.

Electronic wiring also allows you to increase energysavings and decrease management costs, thanks to higherlamp life.

Consumption (W) lamp + ballast

*We considered an average daily dimming equal to 50% of power supply.

CharacteristicsWiring

with lowloss

Wiringballast

Dimmable Wiringballast

Luminaire power 2x58W

Cost Kwh (Euro) 0.18 0.18 0.18

Annual hours of operation

4000 4000 4000

Total energy cost for single luminaire

€ 101.52 €78.48(- 23%)

€39.60(- 61%)

Comparison of energy costs (%)Energy consumptionby luminous flux.

Electronicdimmable

EEI A1 BAT

Low-loss

EEI B2

ElectronicEEI A2 BAT

Electronicdimmable

EEI A1 BAT

Low-loss

C

ElectronicEEI A2 BAT

% P

ow

er

sup

ply

% Luminous level

Page 467: 3F Filippi  "General catalogue 2016"

464

Fluorescent low loss starter wiringThe luminaires are wired with low loss magnetic ballasts, already complying with European Directive 245/2009/EC which repealed the Directive 2000/55/EC concerning energy efficiency of ballasts for fluorescent lamps, with an energy efficiency index EEI = B2, starter switch-on, power supply voltage of 230V-50Hz.Rigid cables cross section. 0.50-0.75-1 mm² (0.75-1 mm² also class II), heat resistant PVC HT 90°C, CEI 20-20.Power factor correction in parallel, cos >0.9 with metallised polypropylene film capacitor, self-regenerating, not containing PCB liquid pollutants, incorporated discharge resistance, safety device, IEC 34-36.LTN connecting terminal block with maximum connecting capacity of 2x2.5 mm² per pole.Cut-out fuse incorporated in terminal block permits any short circuit to be limited to the luminaire affected. No immediate maintenance is necessary because all of the luminaires connected on the same line continue to operate, making it simple locate the failure.All luminaires comply with IEC 60598-1, CEI EN 60598-1 (CEI 34-21) safety standards and EN 55015 electromagnetic compatibility regulations; almost all series are IMQ approved.Suitable for use in rooms with temperatures from -5°C to +25°C (maximum temporary temperature +35°C).For rooms with low temperatures, use of a DEOS safety starter (available on request) is recommended. Temperatures from +25°C to -15°C.

A2 and A3 to electronic ballasts, B1 to very low loss magnetic ballasts, and B2 to low loss magnetic ballasts. Note on magnetic ballasts: on the basis of 2000/55/EC, luminaires with EEI= D ballasts were banned in 2002 and luminaires with EEI= C ballasts were banned in November 2005.

* BAT = Best Available Technology (on the market).

The European Federation of National Manufacturers Associations for Luminaires and Electro-technical Components (CELMA), in collaboration with the association of lamp manufacturers, has developed a new classification system providing, for each lamp type, 7 classes of power absorbed by the lamp+ballast system. These classes are assigned an energy efficiency index (EEI) starting from the most efficient: A1 BAT*, A1, A2 BAT*, A2, A3, B1, B2. Even if there are no direct correlations with a specific technology, A1 BAT* and A1 refer to dimmable electronic ballasts, A2 BAT*,

Very low loss fluorescent wiringSame characteristics as low loss starter wiring, but with 230V-50Hz very low loss magnetic ballasts with an energy efficiency index EEI = B1.

Advantages in using very low loss ballasts:• Reduced internal losses, or a reduction of power losses

dissipated by the system of over 30% compared to standard magnetic ballasts.

• Economical management due to energy savings, particularly evident in the case of prolonged use.

• Greater thermal equilibrium inside the luminaires due to lower temperatures developed by the ballasts, with consequent longer life for all of the wiring components and less need for maintenance works.

Suitable for use in rooms with temperatures from –5°C to +35°C (maximum temporary temperature +45°C).

Ballast classification based on energy efficiency (EEI)

Electrical engineering and electronics

Luminaires Maximum power (W) lamp + ballast system

T8

1x18 26

1x36 43

1x58 67

2x18 43

2x36 87

2x58 134

3x18 69

3x36 129

3x58 201

4x18 86

4x36 174

4x58 268

Compact

1x11 C 15

1x18 C 26

1x24 C 32

1x36 C 43

2x11 C 30

2x18 C 52

2x24 C 64

2x36 C 86

3x24 C 96

RoundT8

1x22 28

1x32 38

2x32+40 88

Luminaires Maximum power (W) lamp + ballast system

T8 1x18 24

1x36 41

1x58 64

2x18 42.5

2x36 82

2x58 128

3x18 67

3x36 123

4x18 85

4x36 164

4x58 256

Compact 2x24 C 61

1x13 CD 21

1x18 CD 24

1x26 CD 32

2x13 CD 42

2x18 CD 48

2x26 CD 64

Page 468: 3F Filippi  "General catalogue 2016"

465

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Electrical engineering and electronicsEmergency fluorescent wiringWiring created with emergency lighting systems with the following characteristics:• Rigid cables, cross section 0.50-0.75-1 mm² (0.75-1 mm² also

Class II), heat resistant PVC HT 90°C, CEI 20-20.• Protective fuse, same characteristics as starter wiring.• 230V-50/60Hz electronic inverter with protection against

excessive battery discharge.• Sealed Nickel-Cadmium or Nickel-Metal Hydride NiMH.• LED to signal presence of power supply and battery charging.• Recharge time 24 hrs.• Running time = 1h minimum under heaviest working conditions.• 3-pole terminal block with incorporated disconnecting fuse for

standard power supply live-earthing-neutral (LTN).• 2-pole terminal block for power supply of the • emergency-recharge.• Complies with IIEC 60598-1, CEI EN 60598-1 (CEI 34-21) and

CEI EN 60598-2-22 (CEI 34-22).• Suitable for rooms with temperature from 0°C to +25°C.

On request:• Inhibition and/or rest mode.• Emergency system with 3hrs duration, with 1/1.5/2hr

duration 12hrs recharge (according to feasibility), wirings with intelligent control systems and centralised or local management of emergency lighting.

• Emergency lighting systems with high luminous flux.• Inhibition remote control: the inhibition remote allows

the lamps to be turned off and also turned back on when running in emergency mode. When power returns, ‘ready-for-emergency’ condition is restored automatically. (as per CEI EN 60598-2-22)

EP permanent emergency lightingWhen power is on, EP luminaires operate like normal luminaires; in the event of power failure, the lamp connected to the emergency lighting system switches on or stays on automatically.In EP luminaires with 2, 3 or 4 lamps, only one lamp switches on in emergency mode.

ENP non-permanent emergency lightingIn ENP luminaires, the lamp switches on only in emergency mode, due to power failure.

Inhibition remote control

Luminous flux in an emergency

The following table shows percentages of luminous flux of lamps in emergency operation.These fluxes are the minimum guaranteed during rated autonomy as required by IEC EN 60598-2-22, and should therefore be used in the design stage.

* High-flux emergency (evaluated on a per-request basis).See the specific section for fluxes in emergency mode for LED luminaires.

Notes• If both the ordinary power supply and emergency recharge

supply derive from a 3-phase system, the phase of the two power supplies (especially with emergency wiring with electronic ballasts) should be the same.

• In case of inhibition via switch (permanent shut-down), this circuit should be considered the security circuit.

Lamp power(W)

Flux percentage in an emergency (%) for 1

hourT8 18 22

36 15,5

58 13,9

58 * 15

T5 14 15

14 * 46

24 9

24 * 33,4

28 10,6

28 * 39

35 12,7

35 * 28,6

49 11,4

49 * 23

54 8,5

54 * 18,2

80 6,8

80 * 14,4

Compact 11 C 15

24 C 11

40 C 8

40 C * 22,5

55 C 9

55 C * 15

18 CD 10

26 CD 9

32 CT 8

42 CT 7

RoundT5

22 T5-R 8

40 T5-R 9

60 T5-R 8

RoundT8

22 TR 11

32 TR 8

Page 469: 3F Filippi  "General catalogue 2016"

466

The single European mark ENEC (European Norms Electrical Certification) certifies that a luminaire conforms to EN European standards. IMQ is one of the European certifying bodies belonging to ENEC. Luminaires approved by IMQ on the basis of European standards are therefore ENEC-certified.

Protection against electric shockStandard IEC EN 60598-1 (CEI 34-21).Luminaires are divided into four classes according to the type of protection provided against electric shock.

Main featuresof the material

Safety precautionsvoltage Symbols

Class 0 No earthing protection device Environment without earth

Class I Earthing protection device provided Connection to protective earth

Class II Additional insulation but no earthing protection device

No precaution necessary

Class III Intended for very low safety voltage

Connection to very lowsafety voltage

III

Marks and standards

All 3F Filippi luminaires bear the CE marking. This marking attests to be fact that the luminaires conform to the requirements set out in Community Directives for electrical materials and that they may be freely marketed throughout the European Union.Directives applicable to lighting products are: • the 2006/95/EC low-voltage

directive• the 2004/108/EC

electromagnetic compatibility directive

• the Ecodesign directive 2009/125/EC

• the RoHS 2011/65/EU directive

The acronym EN refers to the European standards issued by CENELEC (European Committee for Electro-technical Standardisation). These must be adopted by all EU member states by means of national regulatory bodies (in Italy, the CEI). For luminaires, the reference standards are IEC EN 60598-1 (CEI 34-21) and IEC EN 60598-2-22 (CEI 34-22, luminaires for emergency lighting).Conformity to these standards ensures that the luminaires are properly manufactured and can be used to build electrical systems that conform to the requirements stipulated by the applicable legislation (for example, Decree Law no. 37 of 22 January 2008).

A cut-out fuse incorporated in terminal block permits any short circuit to be limited to the luminaire affected.Standard equipment in versions with emergency and ballast; on request in electronic versions.

Electrical engineering and electronics

Page 470: 3F Filippi  "General catalogue 2016"

467

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Our care for the environment goes hand-in-hand with our 0-mile production, whereby all our products are assembled in the same Bologna plant where they are produced.

3D modelling Mould EDM tool

From the design to the finished product

Our products are made with a craftsman's passion and constant innovation, research and attention to design and details:they combine aesthetics and functionality, elements of precision and new technologies, maintenance and reliability facilities, and are excellent value for money.3F Filippi's entire production is performed inside the headquarters in Pian di Macina (province of Bologna, Italy), from moulding of plastics and metals to machining and soldering and painting, all totally automated.The thoroughness and precision of the checks throughout every phase of the company's processes guarantee constant quality of all our products over time.

For 3F Filippi, attention to detail, the quality of the light and the reliability of our products are the starting point on the path we travel alongside our customers. Efficiency is the culmination of our journey – we create a light that can show and give emotion, while hiding its technical soul, able to highlight what it illuminates.

The right product starts first with a discussion, to gain an understanding of the customer's needs and expectations.

Mechanics and Design

Page 471: 3F Filippi  "General catalogue 2016"

468

IPLuminaires with electronic wiring bearing this mark are

versions with limited surface temperature (EN 60598-2-24 and IEC 34-38), and therefore suitable for installation in environments with greater risk in case of fire as per variant V3 of IEC 64-8.

Luminaires not suitable for direct installation on normally flammable

surfaces (suitable only for installation on non-flammable surfaces).

Note: the symbol is present in edition 9 of IEC EN 60598-1.Unless otherwise indicated by the above symbol, luminaires are suitable for installation on normally flammable surfaces. A surface is considered normally flammable if its ignition temperature is at least 200°C and if it does not deform or soften at such a temperature.

Mechanical strengthLuminaires must have adequate mechanical

strength and be built to sustain stress deriving from any unprotected treatment during normal use.Luminaires with a closing diffuser must pass a test with impact energy of 6.5J; impact is produced by letting a 50 mm diameter, 0.51 kg steel ball fall from a height of 1.3 metres, in compliance with IEC EN 60598-1 (CEI 34-21).The IK Code designates the level of protection of electrical equipment housings against mechanical impact (EN 62262 and IEC 70-4).

Marks and standards

Mechanics

Flame and ignition resistance650°C, 850°C, 960°C. The materials in luminaires bearing this mark have passed the glow-wire test at these temperatures in compliance with EN 60598-1 (IEC 34-21).

Temperature classStandard 50014 defines the temperature classes as the maximum temperature of the external surface of the housing of the luminaire in the case of abnormal operation(EN 60598-1 Appendix C):T1 max 450°C, T2 max 300°C, T3 max 200°C, T4 max 135°C, T5 max 100°C, T6 max 85°C.

Ingress protection of housing (IP rating)As per EN 60598-1 (IEC 34-21).

1st number: protection against penetration by solid objects and against contact with live parts.

0 No special protection.

1Protected against solid objects larger than 50 mm. E.g. hands.

2Protected against solid objects larger than 12 mm. E.g. fingers.

3Protected against solid objects larger than 2.5 mm. E.g. tools.

4Protected against solid objects larger than 1 mm.E.g. threads or tapes.

5Protected against dust penetrationthat could damage the luminaire.

6 Fully protected against dust.

2nd number: protection against penetration by liquids.

0 No special protection.

1 Protected against vertical water drips.

2Protected against vertical water drips when tilted up to 15°.

3 Protected against rain when tilted up to 60°.

4 Protected against splashes of water from any direction.

5 Protected against jets of water coming from any direction.

6Totally protected against sea waves or powerful jets of water.

Protection of housing from impacts (IK rating)Requirements as per IEC 34-139.Luminaires - application of code IEC 62262 IK

0.2 JResistance to a blow from an object weighing 200 g dropped from a height of 10 cm.

IK02

0.5 JResistance to a blow from an object weighing 250 g dropped from a height of 20 cm.

IK04

2 JResistance to a blow from an object weighing 500 g dropped from a height of 40 cm.

IK07

5 JResistance to a blow from an object weighing 1.7 kg dropped from a height of 30 cm.

IK08

10 JResistance to a blow from an object weighing 5 kg dropped from a height of 20 cm.

IK09

20 JResistance to a blow from an object weighing 5 kg dropped from a height of 40 cm.

IK10

Coating and standard colours

1. Polyester-based paint, white or grey Ral 9006, UV stabilised, on hot galvanised steel sheet. Resistance to saline mist over 500hrs and damp resistance equal to 700hrs.

2. Epoxy-polyester powder-coated in white Ral 9010, or grey Ral 9006, UV stabilised, applied with triboelectric system for constant and uniform thickness, oven polymerised at 180°C, with phosphate degreasing pretreatment using heavy iron salts. Resistance to saline mist = 300h.

Page 472: 3F Filippi  "General catalogue 2016"

469

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Mechanics

The table only provides a rough indication of the maximum amount of various chemical agents in different compositions.When using these data, bear in mind that they are the results of laboratory tests and are therefore only valid under the same conditions in which the tests were performed; the data should therefore be considered indicative, and it is advisable to perform tests in their actual usage conditions if practical experience is not available.

The temperature and concentration of a chemical substance may significantly affect its compatibility with materials.

• = resistant Δ = relatively resistant, suitability to be evaluated on basis

of application– = not resistant

Some versions of 3F luminaires are also proposed with laminated glass which, in addition to being resistant to the substances listed above, allows for these to be used in environments with food products or with machines with moving parts, with sudden temperature changes and, in general, in all environments requiring total protection against falling fragments.

Resistance to corrosive substances

Chemical substance Methacrylate Polycarbonate Glass Aluminium Steel Stainless steel

Acetone – – • • • •

Acetic acid up to 10% – Δ • – Δ •

Arsenic acid up to 20% • • Δ – Δ

Citric acid up to 10% • • • Δ Δ Δ

Hydrochloric acid up to 20% • • Δ – – –

Chromic acid Δ Δ Δ Δ Δ Δ

Formic acid up to 30% Δ – – – Δ Δ

Nitric acid up to 20% Δ Δ Δ – – Δ

Sulphuric acid up to 30% • • Δ – – –

Seawater • • Δ Δ Δ Δ

Ethyl alcohol – • • • Δ Δ

Isopropyl alcohol Δ – • Δ Δ Δ

Ammonia • – Δ • Δ •

Aniline – – • • • •

Petrol • Δ • • • •

Benzole – – • Δ Δ Δ

Bromine – Δ • Δ

White lime • Δ – • •

Diesel oils • Δ • • •

Sea climate • • Δ Δ Δ Δ

Liquid chlorine (fumes) – – – • – –

Chloroform – – • • • Δ

Calcium chloride • • • • Δ Δ

Ferric chloride • Δ Δ Δ

Hexane • Δ • • Δ Δ

Ether – – • • •

Petroleum ether • Δ • • •

Ethyl ether • – • • •

Phenols – – • Δ • •

Glycerine • Δ • • • •

Hydrocarbons – – • • • •

Methanol – – • Δ • •

Silicone oils Δ • • • •

Food oils and fats • Δ • • •

Mineral oils • – • • • •

Vegetable oils Δ • • •

Diesel oil - naphtha – – • • • •

Ozone • – • • Δ •

Potassium permanganate • • • Δ • •

PVC with plasticizers – – • • •

Soda • • – – – Δ

Caustic soda • – – – •

Zinc sulphate • • • Δ Δ

Aluminium sulphate • • • • Δ Δ

Copper sulphate • • • • Δ Δ

Carbon tetrachloride – – • • • •

Toluene – Δ • • •

Trichloroethylene – – • Δ Δ

Page 473: 3F Filippi  "General catalogue 2016"

470

Get the best from 3F FilippiHow to use our products correctly

3F Filippi take the utmost care when designing and manufacturing our luminaires so that they stand the test of time.Below are some important indications on how to use our products correctly: following these will allow you to enjoy our products for as long as possible.

• 3F Filippi can only guarantee products exclusively when they are installed according to the installation instructions provided with the luminaires. We therefore recommend you do not install our products in any other way than those indicated. In the event that you have differing requirements, please contact our Sales Network or the 3F Filippi Headquarters to request a technical assessment.

• As with installation, maintenance of 3F Filippi products must also be performed according to the instructions: we therefore recommend keeping these safe so that you can consult them before performing any kind of work on the luminaire.

• 3F Filippi products must only be installed on supports which are not subject to vibrations and mechanical stress – this is critical for their correct operation. In the event that it is not possible to avoid this kind of installation, you are invited to contact our Sales Network or the 3F Filippi Headquarters to request a technical assessment.

• Turning on a luminaire leads to an environmental "load" which is often not justified. Despite 3F Filippi's commitment to offering our customers the best energy-saving systems, using lighting only when strictly necessary is still the best way to save money and respect the environment.

• Correct and sensible lighting design can help save more money than you might think: 3F Filippi recommends that lighting projects are carried out by professional, reliable designers who can recommend the best solutions both for you and the environment. Lighting should only be used when necessary.

• 3F Filippi strongly believe in reusing raw materials, and for this reason we are constantly optimising our products to make them more environmentally-friendly. For example, we use a high percentage of recycled board in our packaging, and our luminaires are all produced in a single plant powered by solar panels: these simple measures allow us to limit transport and optimise resources. 3F Filippi invites users to do the same by recycling packaging after installation and correctly disposing of luminaires at the end of their life-cycle.

Page 474: 3F Filippi  "General catalogue 2016"

471

Info

po

int

Datasheets, product updates and specifications on our website: www.3f-filippi.com

Analytical guide

Price listJune 2016

General conditions of saleThe acceptance of orders is always subject to the following conditions:• Delivery deadlines are not binding. • Goods are delivered ex-works. • Samples are always supplied carriage forward and invoiced. • Goods travel at the customer’s risk with any means of shipment,

both carriage forward and carriage paid.• The purchaser may not demand the partial or total cancellation

of orders nor indemnification for delays and reductions of supply caused by force majeure.

• Prices in this list are subject to change without notice or any obligation to communicate this in advance.

• Payments will be valid if made directly to our headquarters. • VAT is payable by the customer.• The Court in whose district the seller has its headquarters will

have exclusive jurisdiction in the event of any and all disputes.

Articles on requestArticles marked On Request are not normally in our warehouse. Where not specified, delivery dates and prices are to be arranged from time to time based on quantity, production availability, and material procurement times.

Because we are constantly improving our products, the luminaires supplied may differ in details, dimensions, equipment, and accessories from the dimensions and illustrations shown in this catalogue. Therefore, quantities, volumes, and indicated weights are not binding.

Sale through electrical distributors

Page 475: 3F Filippi  "General catalogue 2016"

472

Fuse accessory

Luminaireof luminaire

Fuse nominal

current

Code

with glass fuse

with ceramic

fuse

T5 lamps

2A A01385 A01404

1x14-21-24-28-35-39-49-54W

2x14-21-24-28W

3x14W

T8 lamps1x18-36W

2x18W

Compact lamps1x7-11-13-18-26-32W

2x11-13*-18*W

Round lamps1x22-32W

Pack and price for 100 pcs

T5 lamps1x80W

2x35-39-49-54-80W

3x24-28W

4x14-24-28W

T8 lamps1x58W

2x36-58W 3.15A A01387 A01406

3x18W

4x18W

Compact lamps1x40-42-55-57W

2x13**-18**-24-26-32-40-42-55W

Round lamps1x40-55-60W

Pack and price for 100 pcs

Luminaireof luminaire

Fuse nominal current

Code

with glass fuse

with ceramic

fuse

T8 lamps

4A A01389 A01408

3x36-58W

4x36W

Compact lamps3x24-55W

Pack and price for 100 pcs

T5 lamps

6.3A A01391 A01410

4x49-80W

T8 lamps4x58W

Compact lamps4x55W

Pack and price for 100 pcs

The fuse accessory consists of a rigid wire, cross section 1.5 mm², type H07V2-U, connected to the fuse holder with cylindrical 5x20 mm rapid fuse of adequate capacity.Interrupt rating 35A for glass version, 1500A for ceramic version.The wire shall be connected to the live pole on the luminaire terminal block. The live phase wire shall be screwed to the available pole of the fuse holder, which has maximum capacity of 2.5 mm².Pack and price for 100 pcs

Notes: * Version with two-lamp electronic ballast ** Version with starter ballast

Page 476: 3F Filippi  "General catalogue 2016"

473

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

A0006 Fil 180 CP620 Structure 1 0.012 2 82

A0008 Fil 180 CP1240 Structure 1 0.021 3.82 82

A0009 Fil 180 CP1550 Structure 1 0.026 4.65 82

A0011 Fil 220 CP620 Structure 1 0.015 2.26 82

A0013 Fil 220 CP1240 Structure 1 0.026 4.15 82

A0014 Fil 220 CP1550 Structure 1 0.031 5.13 82

A0016 32 IF (PVC closing top Fil 180-620) 25 0.012 5.75 85

A0018 32 MH (PVC closing top Fil 180-1240) 25 0.024 10.75 85

A0019 32 HA (PVC closing top Fil 180-1550) 25 0.030 13.25 85

A0021 Fil 180 AB620 (steel closing top) 16 0.020 4 86

A0023 Fil 180 AB1240 (steel closing top) 16 0.039 13.76 86

A0024 Fil 180 AB1550 (steel closing top) 16 0.048 16.48 86

A0026 Fil 220 AB620 (steel closing top) 8 0.012 5.2 86

A0028 Fil 220 AB1240 (steel closing top) 8 0.021 8.32 86

A0029 Fil 220 AB1550 (steel closing top) 8 0.026 10.8 86

A0030 Fil 180 CC (continuous channel kit) 150 0.039 6.6 82

A0031 Fil 220 CC (continuous channel kit) 100 0.039 4.5 82

A0033 Fil 180 DT (element for branch) 50 0.033 5.65 83

A0034 Pair of white cylinders 70 0.033 3.99 32, 82

A0035 Aluminium tube 1.5 m white 10 0.030 5 32, 82

A0036 Fil 180 BL (box for branch) 6 0.053 14.1 82

A0037 Fil 220 BL (box for branch) 6 0.053 15.51 82

A0038 White articulated connecting element 30 0.039 4.5 83

A0039 Pair of white end caps Fil 180 35 0.033 5.25 83, 280

A0040 Pair of white end caps Fil 220 35 0.039 6.3 83

A0042 Fil 180 SS (sliding bracket) 100 0.033 15 83, 280

A0043 Fil 220 SS (sliding bracket) 80 0.033 15.2 83

A0045 Adjustable suspension for channel 1m 40 0.039 11.6 84, 280

A0046 Adjustable suspension for channel 1.5m 40 0.039 12 84, 280

A0047 Adjustable suspension for channel 2m 40 0.039 13.6 84, 280

A0051 34 MF (variable lamp focusing Fil 220 T8) 200 0.033 3.6 85

A0052 Fil 15 FP (wall-mounting bracket Fil 180) 50 0.033 17 86

A0053 Fil 19 BF (cable clip) 20 0.033 5.5 84

A0058 Flat diffuser PC transp. Fil180 36 sing. 50 0.021 20 85

A0059 Flat diffuser PC transp. Fil180 58 sing. 40 0.026 20.2 85

A0060 21 V2 (PC diffuser 58W Fil180/3F1) 20 0.059 12 85

A0061 21 V0 (PC diffuser 58W Fil180/3F1) 20 0.059 12 85

A0062 21 V2C (PC diffuser 36W Fil180/3F1) 20 0.064 10 85

A0063 21 V0C (PC diffuser 36W Fil180/3F1) 20 0.064 10 85

A0064 21 RD (PC single diffuser transp. 36 WFil220) 25 0.021 10.25 85

A0065 21 AT (PC single diffuser transp. 58 WFil220) 25 0.026 12.75 85

A0066 Strength. Brack.+Connect. Kit - Fil 180 10 0.011 5 82

A0067 Strength. Brack.+Connect. Kit - Fil 220 10 0.011 6 82

A0090 Bracket/5-pole terminal block 100 0.033 10 32, 41

A0114 Rose 110 (Adjust. susp.1m wired with 5-pole cable) 25 0.039 12.25 83, 280

A0124 Rose 110 (Adjust. susp.1m unwired) 50 0.039 8.5 83, 280

A0125 Rose 110 (Adjust. susp.1m wired with 4-pole cable) 25 0.039 12 83

A0128 Rose 86 (5-pole wired boss) 25 0.039 8.75 281

A0130 Rose 86 (4-pole wired boss) 25 0.039 8.5 40, 84

A0160 Inox clips 3F Linda L660-4pcs 140 0.033 7 334

A0161 Inox clips 3F Linda L1270-8pcs 125 0.033 12.5 334

A0162 Inox clips 3F Linda L1570-10pcs 100 0.033 15 334

A0164 Pair of closing end caps L 450 T5 1 0.004 .18 206

A0170 15BS 200 0.033 24.6 182, 203, 215

Code ItemPacking

Pallets PagePcs m³ Kg

A0173 15HI 150 0.033 18189, 196206, 222

A0174 15DP 200 0.033 25 215

A0175 15GF 200 0.033 25 215

A0176 15XB 150 0.033 18 215

A0177 15ZH 200 0.033 25182, 189, 196203, 215, 222

A0179 15LB 200 0.033 18 182

A0187 Anti-condensation cable gland 50 0.004 1 227, 335, 369

A0189 Reinforcing bracket Lucequadro for pan./plast. 20 0.008 9.6 132

A0194 Diffuser IP44 (3F Dodeca 220) 20 0.026 2 152

A0195 Transparent glass (3F Dodeca 220, 220 AC) 5 0.012 1.7 152

A0196 Moulded glass (3F Dodeca 220, 220 AC) 5 0.012 1.7 152

A0197 Transparent glass (3F Dodeca 300) 4 0.011 2.52 152

A0198 Moulded glass (3F Dodeca 300) 4 0.011 2.52 152

A0202 False ceiling bracket - for luminaire D.220 10 0.020 8 139, 152

A0203 False ceiling bracket- for luminaire D.300 10 0.039 10 152

A0204 Grid bracket h40mm - for luminaire D.220 10 0.081 7.5 139, 153

A0205 Grid bracket h40mm - for luminaire D.300 10 0.157 11.5 153

A0210 Wireguard 3F Cub 1 0.095 5 389

A0213 Ceiling-mounted bracket 10 0.033 8.2 116, 389

A0214 Metal pan. reinforcing bracket (3F Dodeca 220) 10 0.095 12 139, 153

A0215 Metal pan. reinforcing bracket (3F Dodeca 300) 8 0.095 10.8 153

A0400 16 CLE (wide recup.Linda 2x18) 20 0.005 2 336

A0401 16 MRA (wide recup. Linda 2x36) 20 0.010 4 336

A0402 16 GPA (wide recup. Linda 2x58) 20 0.012 5.5 336

A0406 16 HZD (super wide. recup. Linda 2x18 ) 20 0.005 2 336

A0407 16 NBH (super wide. recup. Linda 2x36) 20 0.010 4 336

A0408 16 PCL (super wide. recup.Linda 2x58 20 0.012 5.5 336

A0412 16 DRI (conc. recup.L 2x18) 20 0.005 2 336

A0413 16 REC (conc. recup.Linda 2x36) 20 0.010 4 336

A0414 16 LZC (conc. recup.Linda 2x58) 20 0.012 5.5 336

A0418 16 EFG (conc. recup.Linda LA 1x18) 20 0.005 2 336

A0419 16 QST (conc. recup.Linda LA 1x36) 20 0.010 4 336

A0420 16 ATB (conc.recup. Linda LA 1x58) 20 0.012 5.5 336

A0424 16 SNN (conc. recup.Linda 1x18) 20 0.002 1.5 337

A0425 16 THO (conc. recup.Linda 1x36) 20 0.004 3 337

A0426 16 UIP (conc. recup.Linda 1x58) 20 0.005 4 337

A0430 16 FAS (asym. rec. Linda LA 1x18) 20 0.005 2 337

A0431 16 GDM (asym. rec. Linda LA 1x36) 20 0.010 4 337

A0432 16 BZF ( asym. rec. Linda LA 1x58) 20 0.012 5.5 337

A0436 16 VMR (asym. recup. Linda 1x18) 20 0.002 1.5 337

A0437 16 ZOQ (asym. recup. Linda 1x36) 20 0.004 3 337

A0438 16 XGS (asym. recup. Linda 1x58) 20 0.005 4 337

A0447 3F Linda though line L1570 50 0.069 10 335

A0449 15 GZI (w/brack. Linda L300) 20 0.005 3 334

A0450 15 RIT (w/brack.+ hooks Linda L660-1270-1570) 20 0.005 2.5 334

A0451 15 MBI (w/brack. Linda L300) 20 0.011 5 334

A0452 15 FBR (w/brack.+ hooks Linda L660-1270-1570) 20 0.011 5 334

A0455 Wire guard 180x1330 03F/Linda 1 0.016 3.5 334

A0456 Wire guard 180x1330 03F/Linda 1 0.020 4 334

A0457 Wire guard280x1330 03F/Linda/Beta 1 0.024 4 334, 369

A0458 Wire guard 280x1630 03F/Linda/Beta 1 0.030 4.5 334, 369

A0462 13 GSI (pair of susp. hooks Linda L300) 50 0.007 3 334

A0463 13 TRM (pair of susp. hooks Linda L660-1270-1570) 50 0.007 3.5 334

A0464 26 CSG (pictogram P1 Linda L300) 100 0.006 2.5 335

Page 477: 3F Filippi  "General catalogue 2016"

474

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

A0465 26 MTH (pictogram P1 Linda L660) 100 0.013 2.5 335

A0466 26 DVI (pictogram P2 Linda L300) 100 0.006 2.5 335

A0467 26 MVL (pictogram P2 Linda L660) 100 0.013 2.5 335

A0468 26 GZM (pictogram P3 Linda L300) 100 0.006 2.5 335

A0469 26 PXN (pictogram P3 Linda L660) 100 0.013 2.5 335

A0477 Safety wire 125 0.033 6.25 182, 189

A0483 Sliding bracket Barraluce L 400 0.033 16 236

A0490 Connection to the earth 1000 0.011 3 261

A0500 13 DH (pair of susp. galvanised steel hooks i3F) 200 0.033 22 369

A0501 13 HC (pair of susp. stainless steel hooks A3F) 200 0.033 22 369

A0503 15 CD (pair of bracket and hooks A3F) 100 0.033 29 369

A0508 20 TKA (casc. conn. line i3F/A3F 36) 50 0.069 10 369

A0509 20 ZFE (casc. conn. line i3F/A3F 58) 50 0.069 10 369

A0528 Wireguard Beta 4x54-6x54 1 0.095 6.5 376

A0529 Wireguard Beta 4x58/80-6x49 1 0.117 8 376

A0601 White linear connecting element 40 mm 30 0.039 9 39

A0602 White linear connecting element 200 mm 10 0.039 8.5 39

A0603 White linear connecting element 500 mm 6 0.039 6.45 39

A0604 White linear connecting element 1100 mm 10 0.124 32.5 39

A0605 White joint 3F Canda/wall 600 mm 10 0.039 20.5 39

A0606 White joint 3F Canda/wall 1100 mm 10 0.124 31.9 39

A0607 Pair of white cylinders 3F Canda 70 0.033 3.5 41

A0608 White Alluminium Tube Ø.20 mm 1,5 m 14 0.012 4.34 41

A0609 White wall-mounting boss 3F Canda 100 0.011 5 41

A0610 Fixed suspension with case 0.3 m 40 0.039 8 39

A0611 Fixed suspension with case 0.5 m 40 0.039 8.2 39

A0612 Fixed suspension with case 0.8 m 40 0.039 8.4 39

A0613 Fixed suspension with case 1 m 40 0.039 8.6 39

A0614 Wired fixed suspension with case 0.3 m 20 0.039 9 39

A0615 Wired fixed suspension with case 0.5 m 20 0.039 9.2 39

A0616 Wired fixed suspension with case 0.8 m 20 0.039 9.4 39

A0617 Wired fixed suspension with case 1 m 20 0.039 9.6 39

A0618 Adjustable suspension with case 1 m 40 0.039 9.4 39

A0619 Wired adjustable suspension with case 1 m 20 0.039 10 39

A0620 Spool with stainless steel cable diam. 1,25mm 100 m 1 0.011 .862, 84

96, 280

A0622 Clamp 1 hole - 100 pcs 100 0.004 .3562, 84

96, 281

A0623 Pair of spacers 3F Canda 60 mm ceiling 20 0.039 9.8 40

A0629 White sliding bracket 3F Canda 80 0.033 16 40

A0631 Pair of white wall-mounting brackets 3F Canda 50 0.033 20 40

A0634 Casc. conn. Line 5x1.5 3F Canda 1300 50 0.069 9.5 40

A0635 Casc. conn. Line 5x1.5 3F Canda 1600 50 0.069 10.5 40

A0645 Semi-recessed bracket (3F Canda Quadrato) 10 0.012 8 39

A0652 Couple of brackets for ceiling installation - 3F LEM 20 0.011 2 303

A0653 Couple of fixing carabiniers for chain installation - 3F LEM 20 0.011 3 303

A0660 Suspension with adjustment for 3F Zeta - 1m 100 0.033 12 14

A0661 Suspension with adjustment for 3F Zeta - 2 m 100 0.033 12.5 14

A0662 Suspension with adjustment for 3F Zeta - 3 m 100 0.033 13 14

A0663 Suspension with adjustment for 3F Zeta - 4 m 100 0.033 13.5 14

A0664 Suspension with adjustment for 3F Zeta - 5 m 100 0.033 14 14

A0665 Suspension with adjustment for 3F Zeta - 6 m 100 0.033 14.5 14

A0670 16 PSG ( wide recup. Linda 2x14 T5 ) 20 0.005 2 336

A0671 16 RTA (wide recup. Linda 2x28 T5) 20 0.010 4 336

A0672 16 BMT (wide recup. Linda 2x35-49 T5) 20 0.012 5.5 336

A0673 16 ALN (s. wide recup. Linda 2x14 T5 ) 20 0.005 2 336

Code ItemPacking

Pallets PagePcs m³ Kg

A0674 16 FGP (s. wide recup. Linda 2x28 T5) 20 0.010 4 336

A0675 16 VBC (s. wide recup. Linda 2x35-49 T5 ) 20 0.012 5.5 336

A0676 16 CZA (conc. recup.Linda 2x14 T5) 20 0.005 2 336

A0677 16 TLS (conc. recup.Linda 2x28 T5) 20 0.010 4 336

A0678 16 GHR (conc. recup. Linda 2x35-49 T5) 20 0.012 5.5 336

A0682 16 ZRB (conc. recup.Linda 1x14 T5) 20 0.002 1.5 337

A0683 16 UCL (conc. recup.Linda 1x28 T5) 20 0.004 3 337

A0684 16 EDW (conc. recup.Linda 1x35-49-80 T5) 20 0.005 4 337

A0688 16 KXH (asym. recup. Linda 1x14 T5) 20 0.002 1.5 337

A0689 16 NQE (asym. recup. Linda 1x28 T5) 20 0.004 3 337

A0690 16 WAZ ( asym. rec. Linda 1x35-49-80 T5) 20 0.005 4 337

A0693 Suspension with adjustment for Barraluce P - 1m 1 122

A0694 Suspension with adjustment for Barraluce P - 2 m 1 122

A0695 Suspension with adjustment for Barraluce P - 3 m 1 122

A0696 Suspension with adjustment for Barraluce P - 4 m 1 122

A0697 Suspension with adjustment for Barraluce P - 5 m 1 122

A0698 Suspension with adjustment for Barraluce P - 6 m 1 122

A0714 Clamp 2 holes - 100 pcs 100 259

A0716 Coil galvanized cable diam. 1.5mm - 100m 1 1 259

A0717 Coil galvanized cable diam. 1.5mm - 500m 1 7.2 259

A0718 Coil galvanized cable diam. 1.5mm - 1000m 1 12.2 259

A0720 Wieland (white plug) 50 0.011 5 183, 189

A0721 Wieland (white plug) 50 0.011 5 183, 189

A0722 Ensto (white plug+ adapter) 50 0.011 5 183, 189

A0725 Wieland (black plug) 50 0.011 5 183, 189

A0726 Wieland (black plug) 50 0.011 5 183, 189

A0727 Ensto (black plug+ adapter) 50 0.011 5 183, 189

A0762 Adjustable suspension for channel 3m 40 0.039 16 84, 280

A0766 Adjustable suspension for channel 4m 40 0.039 20.8 84, 280

A0770 Adjustable suspension for channel 6m 40 0.039 24.4 84, 280

A0846 Flat diffuser PC transp. Fil180 28-54 sing. 50 0.021 7.5 85

A0847 Flat diffuser PC transp. Fil180 35-49 -80 sing. 50 0.026 9.5 85

A0848 Flat diffuser PC transp. Fil180 28-54 chan. 50 0.021 7.75 85

A0849 Flat diffuser PC transp. Fil180 35-49 -80 chan. 50 0.026 9.75 85

A0862 Flat diffuser PC transp. Fil220 28-54 sing. 50 0.021 10 85

A0863 Flat diffuser PC transp. Fil220 35-49-80 sing. 50 0.026 11.75 85

A0864 Flat diffuser PC transp. Fil220 28-54 chan. 50 0.021 10.25 85

A0865 Flat diffuser PC transp. Fil220 35-49-80 chan. 50 0.026 12 85

A0869 Grey connecting element with boss for luminaires 10 0.012 3.5 61

A0870 White connecting element with boss for luminaires 10 0.012 3.5 61

A0871 Grey connecting element to wall with boss for luminaires 10 0.033 3.4 61

A0872 White connecting element to wall with boss for luminaires 10 0.033 3.4 61

A0875 Connecting bracket for linear channels or branches 100 0.033 9 60

A0877 Bracket for T-branch for 3F Travetta 100 0.033 11 61

A0878 Bracket for X-branch for 3F Travetta 100 0.033 11 61

A0880 Connecting element 190x190 3F Travetta GR 12 0.039 11.16 60

A0882 Connecting element 190x210 3F Travetta GR 12 0.039 9.6 60

A0883 Connecting element 190x510 3F Travetta GR 4 0.039 7.6 60

A0884 Connecting element 190x810 3F Travetta GR 7 0.124 21.56 60

A0885 Connecting element 190x1110 3F Travetta GR 7 0.124 29.4 60

A0892 White connecting element 190x190 3F Travetta GR 12 0.039 11.16 60

A0894 White connecting element 190x210 3F Travetta GR 12 0.039 9.6 60

A0895 White connecting element 190x510 3F Travetta GR 4 0.039 7.6 60

A0896 White connecting element 190x810 3F Travetta GR 7 0.124 21.56 60

Page 478: 3F Filippi  "General catalogue 2016"

475

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

A0897 White connecting element 190x1110 3F Travetta GR 7 0.124 29.4 60

A0937 Connecting element lum/wall 810 3F Travetta GR 8 0.124 22.8 60

A0938 Connecting element lum/wall 1110 3F Travetta GR 8 0.124 31.6 60

A0941 White connecting element lum/wall 810 3F Travetta 8 0.124 22.8 60

A0942 White connecting element lum/wall 1110 3F Travetta 8 0.124 31.6 60

A0945 Branches elem.190x310 3F Travetta GR 8 0.039 8.8 61

A0946 Branches elem.190x460 3F Travetta GR 4 0.039 6.6 61

A0951 White branches elem. 190x310 3F Travetta 8 0.039 8.8 61

A0952 White branches elem. 190x460 3F Travetta 4 0.039 6.6 61

A3001 Controller HCL Basic 1 .1 431

A3002 Controller HCL Plus 1 .1 431

A3003 Touch Panel HCL 1 .07 431

A3004 Clock Module 1 .02 431

A3008 Repeater DALI ext 1 .1 416

A3009 Repeater DALI DIN 1 .2 416

A3010 Box for Repeater DALI 1 .13 416

A3011 Sensor A DALI 1 .25 425

A3012 Sensor A DALI ext 1 .25 425

A3013 Sensor A on/off 1 .25 425

A3014 Sensor A on/off-ext 1 .25 425

A3015 Sensor B Dual-DALI 1 .28 426

A3016 Sensor B DALI ext 1 .28 425

A3017 Sensor B DALI 1 .28 425

A3018 Sensor B on/off 1 .28 425

A3019 Sensor B on/off-ext 1 .28 425

A3020 Programmer IR 1 .08 426

A3021 Remote controller IR 1 .1 426

A3022 IR-Adapter for Smartphone 1 .08 426

A4151 Binario 3F - L1000 - B 1 1.1 265

A4152 Binario 3F - L2000 - B 1 2.2 265

A4153 Binario 3F - L3000 - B 1 3.3 265

A4154 Binario 3F - L4000 - B 1 4.4 265

A4158 Binario 3F - L1000 - GR 1 1.1 265

A4159 Binario 3F - L2000 - GR 1 2.2 265

A4160 Binario 3F - L3000 - GR 1 3.3 265

A4161 Binario 3F - L4000 - GR 1 4.4 265

A4166 Feeding head DX - GR 1 .1 265

A4167 Central feeding - GR 1 .2 266

A4168 Flexible connecting element - GR 1 .21 267

A4169 L-joint - EXT - GR 1 .2 268

A4170 T-joint - EXT + SX - GR 1 .29 268

A4171 Cross joint - GR 1 .39 269

A4172 End cap - GR 1 .01 266

A4173 PVC closing top - L1000 - GR 1 .07 269

A4174 Feeding head DX - B 1 .1 265

A4175 Central feeding - B 1 .2 266

A4176 Flexible connecting element - B 1 .21 267

A4177 L-joint - EXT - B 1 .2 268

A4178 T-joint - EXT + SX - B 1 .29 268

A4179 Cross joint - B 1 .39 269

A4180 End cap - B 1 .01 266

A4181 PVC closing top - L1000 - B 1 .07 269

A4182 Linear connecting element - GR 1 .05 267

A4183 Steel bracket for ceiling mounting 1 .02 269

Code ItemPacking

Pallets PagePcs m³ Kg

A4184 Aluminum bracket for suspension installation 1 .03 269

A4185 Controller for suspension 1 .02 269

A4186 Rose chromed brass ceiling mounting cable 1 .01 269

A4187 Cable suspension with ball - L = 2000 1 .025 269

A4188 Linear connecting element - B 1 .05 267

A4190 Feeding head SX - GR 1 .1 265

A4191 L-joint - INT - GR 1 .2 268

A4192 T-joint - EXT + DX - GR 1 .29 268

A4193 T-joint - INT + SX - GR 1 .29 268

A4194 T-joint - INT + DX - GR 1 .29 268

A4196 feeding head SX - B 1 .1 265

A4197 L-joint - INT - B 1 .2 268

A4198 T-joint - EXT + DX - B 1 .2 268

A4199 T-joint - INT + SX - B 1 .29 268

A4200 T-joint - INT + DX - B 1 .2 268

A5012 Kit LED i3F 75,A3F 90 - L1565 - 2x30W CONC + PC 1 0.039 3 351

A5026 Kit LED i3F 75,A3F 90 - L1565 - 2x30W + PC 2 0.039 4.6 351

A5057 Kit LED i3F 75,A3F 90,A3F 92 - L1265 - 2x18W + PC 2 0.031 5.2 351

A5103 Kit LED i3F 76,A3F 91 - L1565 - 2x30W CONC 1 0.039 2.7 351

A5117 Kit LED i3F 76,A3F 91 - L1565 - 2x30W 2 0.030 4 351

A5148 Kit LED i3F 76,A3F 91,A3F 93 - L1265 - 2x18W 2 0.024 3.2 351

A5184 Printed glass Beta 2x i3F 76 - L1565 3 0.039 14.4 352

A5185 Printed glass Beta 2x i3F 76 - L1265 3 0.031 12 352

A01314 White rectangular case suspension- fixed 0,3m 50 0.039 5.5 62

A01315 White rectangular case suspension- fixed 0,5m 50 0.039 6 62

A01317 White rectangular case suspension- fixed 1m 50 0.039 7 62

A01318 White rectangular case suspension-adj. 1 m 50 0.039 7.5 61, 96

A01321 Wired susp. 5P white rectangular case-fixed 0,3m 20 0.039 7.8 62

A01322 Wired susp. 5P white rectangular case-fixed 0,5m 20 0.039 8.2 62

A01324 Wired suspension 5P white rectangular case-fixed 1m 20 0.039 10.6 62

A01325 Wired suspension 5P white rectangular case-adj.1 m 20 0.039 11 61, 96

A01350 Presence and light sensor Fly2 B 5 0.011 1.25 96

A01351 Presence and light sensor Fly2 GR 5 0.011 1.25 96

A01353 Connecting element for Fly2 GR 1 0.007 .32 96

A01368 Travetta B joint closing cap 10 0.011 4 61

A01370 Travetta GR joint closing cap 10 0.011 4 61

A01385 Fuse-holder and glass fuses 2A 100 0.011 5 472

A01387 Fuse-holder and glass fuses 3.15A 100 0.011 5 472

A01389 Fuse-holder and glass fuses 4A 100 0.011 5 472

A01391 Fuse-holder and glass fuses 6.3A 100 0.011 5 472

A01404 Fuse-holder and ceramic fuses 2A 100 0.011 5 472

A01406 Fuse-holder and ceramic fuses 3.15A 100 0.011 5 472

A01408 Fuse-holder and ceramic fuses 4A 100 0.011 5 472

A01410 Fuse-holder and ceramic fuses 6.3A 100 0.011 5 472

A01417 Pair end caps Barraluce L channel diffuser 1 0.011 .1 236

A01418 Pair end caps Barraluce L channel louvre 1 0.011 .1 236

A01420 Couple brackets for Barraluce L 1 .4 236

A01423 Linear connecting elements Barraluce 1 0.011 .2 122, 236

A01429 Sliding bracket for Barraluce P 1 0.011 .1 122

A01434 Pair of end caps for Barraluce L channels with diffuser 1 0.011 .1 122

A01457 Susp with Rose 110 – Adj 1m – Cable 2m 25 0.039 12.25 28

A01523 Grid bracket h50mm - for luminaire D.220 10 0.081 8 139, 152

A01524 Grid bracket h50mm - for luminaire D.300 10 0.157 12 153

A02484 5P socket/plug terminal block Beginning/End Channel 50 0.011 2 122, 236, 281

Page 479: 3F Filippi  "General catalogue 2016"

476

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

A02562 Caddy for exposed profiles of 24 mm 20 0.004 1 14, 258

A02597 Branch 50cm, plug-socket 5P 10 0.008 1 281

A20018 3F Linux S 5P L3556 2 0.021 8 247

A20019 3F Linux S 5P L1778 2 0.021 4 247

A20025 3F Linux S 7P L3556 2 0.021 8.4 247

A20026 3F Linux S 7P L1778 2 0.021 4.4 247

A20083 3F Linux L 60 LED BAT L1778 1 0.019 2.65 249

A20084 3F Linux L 50 LED BAT L1778 1 0.019 2.65 249

A20085 3F Linux L 40 LED BAT L1778 1 0.019 2.65 249

A20097 3F Linux L 60 LED DALI BAT L1778 1 0.019 2.7 249

A20098 3F Linux L 50 LED DALI BAT L1778 1 0.019 2.7 249

A20099 3F Linux L 40 LED DALI BAT L1778 1 0.019 2.7 249

A20125 3F Linux L 60 LED AMPIO L1778 1 0.019 2.65 249

A20126 3F Linux L 50 LED AMPIO L1778 1 0.019 2.65 249

A20127 3F Linux L 40 LED AMPIO L1778 1 0.019 2.65 249

A20139 3F Linux L 60 LED DALI AMPIO L1778 1 0.019 2.7 249

A20140 3F Linux L 50 LED DALI AMPIO L1778 1 0.019 2.7 249

A20141 3F Linux L 40 LED DALI AMPIO L1778 1 0.019 2.7 249

A20167 3F Linux L 60 LED CONC L1778 1 0.019 2.65 250

A20181 3F Linux L 60 LED DALI CONC L1778 1 0.019 2.7 250

A20335 3F Linux D 2x30 LED L1778 1 0.019 3 255

A20336 3F Linux D 2x22 LED L1778 1 0.019 3 255

A20349 3F Linux D 2x30 LED DALI L1778 1 0.019 3 255

A20350 3F Linux D 2x22 LED DALI L1778 1 0.019 3 255

A20433 Linear connecting element for 3F Linux 10 0.011 2 259

A20434 T-Connecting element for 3F Linux 1 259

A20436 L-Connecting element 3F L Linux 1 259

A20442 Closing Top between 3F Linux L or D - L1778 5 0.019 2 260

A20443 Closing Top for luminaires - L1778 10 0.019 3.6 260

A20448 Pair of closing end 3F Linux 100 0.033 6 260

A20450 Sliding bracket with regulator for suspension installation 250 0.033 20 258

A20451 Sliding bracket for ceiling installation 400 0.033 16 258

A20452 Stainless steel hook for chain 400 0.033 12 14, 258

A20453 S-shaped chain hook with sliding bracket 3F Linux 1 258

A20454 5-poles socket-pin terminal block 3F Linux S 1 260

A20455 7-poles socket-pin terminal block 3F Linux S 1 260

A20459 5-poles socket-pin branch (L-shaped) 3F Linux S 1 259

A20460 7-poles socket-pin branch (L-shaped) 3F Linux S 1 259

A20464 5-poles socket-pin branch (T-shaped) 3F Linux S 1 259

A20465 7-poles socket-pin branch (T-shaped) 3F Linux S 1 259

A20470 Pair of mounting brackets 3F devices on Linux S 1 260

A20474 Safety screw for locking the sliding bracket 1 0.011 .01 258

A20476 Single contact pin 50 0.005 12.5 261

A20479 Power cable for luminaires, 3-pole 1 261

A20480 Power cable for luminaires, 5-pole 1 261

A20486 Suspension without adjustment for 3F Linux - 1m 100 0.033 8 258

A20487 Suspension without adjustment for 3F Linux - 2 m 100 0.033 9 258

A20488 Suspension without adjustment for 3F Linux - 3 m 100 0.033 10 258

A20489 Suspension without adjustment for 3F Linux - 4 m 100 0.033 11 258

A20490 Suspension without adjustment for 3F Linux - 5 m 100 0.033 12 258

A20491 Suspension without adjustment for 3F Linux - 6 m 100 0.033 13 258

A20500Central feeding 5-poles socket-pin terminal block 3F Linux S

1 260

A20501Central feeding 7-poles socket-pin terminal block 3F Linux S

1 260

A20511 3F Linux DR 2x30 LED L1778 1 0.019 3 257

Code ItemPacking

Pallets PagePcs m³ Kg

A20512 3F Linux DR 2x22 LED L1778 1 0.019 3 257

A20525 3F Linux DR 2x30 LED DALI L1778 1 0.019 3 257

A20526 3F Linux DR 2x22 LED DALI L1778 1 0.019 3 257

1435 03F 1x18 1 0.008 1.95 180s 111

1436 03F 1x36 1 0.015 3.13 90s 111

1437 03F 1x58 1 0.019 4 90s 111

1438 03F 2x18 1 0.012 2.51 120s 111

1439 03F 2x36 1 0.023 4.8 60s 111

1440 03F 2x58 1 0.028 6.4 60s 111

1441 03F 3x36 1 0.028 6.67 42s 111

1443 03F 1x22 1 0.011 2.26 108s 111

1444 03F 1x32 1 0.011 2.38 108s 111

1445 03F 2x32+40 1 0.017 3.7 68s 111

1446 03F 4x18 1 0.034 6.1 35s 111

1575 Mira Par 1x55 C HF 1 0.013 3.5 90s 31

1576 Mira Par 2x55 C HF 1 0.013 3.7 90s 31

1577 Mira Par 1x36 HF 1 0.024 5.55 46s 31

1578 Mira Par 1x58 HF 1 0.030 6.85 46s 31

1580 Mira Par 2x36 HF 1 0.024 5.8 46s 31

1581 Mira Par 2x58 HF 1 0.030 7.15 46s 31

1594 Mira Par DE 2x28-54 T5 HF 1 0.024 5.8 90s 31

1597 Mira Par DE 2x14-24 T5 HF 1 0.013 3.7 90s 31

1598 Mira Par DE 2x35-49-80 T5 HF 1 0.024 7.2 90s 31

1949 3FI GER 1x15 1 0.011 2.95 50s 409

1950 3FI GER 1x30 1 0.019 4.43 100s 409

1959 Mira Par LED 4x12W IND L675 1 0.013 3.7 90s 29

1961 Mira Par LED DE 4x12W L675 1 0.013 3.6 90s 29

2002 L 323x18 LD HF 2M 2 0.064 8.8 4s+15d 168

2003 L 324x18 LD HF DA 2M 2 0.064 9.8 4s+15d 168

2012 L 323x18 HF 2MG 2 0.064 8.4 4s+15d 170

2013 L 324x18 HF DA 2MG 2 0.064 9.4 4s+15d 170

2022 L 323x18 LD HF 2US 2 0.064 8.8 4s+15d 172

2023 L 324x18 LD HF DA 2US 2 0.064 9.8 4s+15d 172

2032 L 323x18 HF 2S 2 0.064 8.4 4s+15d 174

2033 L 324x18 HF DA 2S 2 0.064 9.4 4s+15d 174

2052 L 323x18 LD HF 3AO 2 0.064 8.8 4s+15d 176

2053 L 324x18 LD HF DA 3AO 2 0.064 9.8 4s+15d 176

2175 L 324x14 T5 LD HF SP IP54 1 0.037 5.8 28s 179

2177 L 324x14 T5 LD HF EP SP IP54 1 0.037 6.5 28s 179

2190 L 322x28 T5 LD HF 2MG 1 0.037 6.1 33s 169

2191 L 323x28 T5 LD HF 2MG 1 0.077 9.6 14s 169

2192 L 322x28 T5 LD HF 2S 1 0.037 6.1 33s 173

2193 L 323x28 T5 LD HF 2S 1 0.077 9.6 14s 173

2222 L 403x18 HF 3AO 2 0.076 10.9 2s+13d 202

2223 L 404x18 HF 3AO 2 0.076 11.2 2s+13d 202

2224 L 403x18 HF SP 2 0.076 11.7 2s+13d 202

2225 L 404x18 HF SP 2 0.076 12.1 2s+13d 202

2226 L 403x18 HF 2US 2 0.076 12.7 2s+13d 200

2227 L 404x18 HF 2US 2 0.076 12.7 2s+13d 200

2241 L 403x18 HF 2S 2 0.076 10.9 2s+13d 201

2242 L 404x18 HF 2S 2 0.076 11.2 2s+13d 201

2244 L 403x18 HF 2M 2 0.076 10.9 2s+13d 199

2245 L 404x18 HF 2M 2 0.076 11.2 2s+13d 199

2247 L 403x18 HF 2MG 2 0.076 10.9 2s+13d 200

Page 480: 3F Filippi  "General catalogue 2016"

477

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

2248 L 404x18 HF 2MG 2 0.076 11.2 2s+13d 200

2532 L 583x55 C LD HF CR RVS 1 0.053 10.5 18s 219

2534 L 583x55 C LD HF CR 2US VT 1 0.053 11 18s 221

2578 L 593x55C HF RVS 1 0.054 11.5 20s 225

2589 L 593x55C HF 2US VT 1 0.054 11.5 20s 226

2760 L 324x18 HF 2S 2 0.064 8.4 4s+15d 174

2761 L 324x18 HF EP 2S 1 0.031 4.7 32s 174

2792 L 324x18 HF 2MG 2 0.064 8.4 4s+15d 170

2793 L 324x18 HF EP 2MG 1 0.031 4.7 32s 170

2804 L 324x14 T5 LD HF VS 1 0.030 7 32s 179

2805 L 324x14 T5 LD HF EP VS 1 0.030 7.5 32s 179

2825 L 353x55 C LD HF COM 2 0.061 10.2 4s+15d 187

2826 L 353x55 C LD HF EP COM 1 0.050 6.1 18s 187

2827 L 352x55 C LD HF RSP 54V 1 0.030 6.1 32s 187

2828 L 352x55 C LD HF EP RSP 54V 1 0.030 6.9 32s 187

2831 L 352x55 C LD HF RVS 54V 1 0.030 8 32s 188

2832 L 352x55 C LD HF EP RVS 54V 1 0.030 8.8 32s 188

2837 L 352x55 C LD HF RVSS 1 0.042 12.9 26s 188

2838 L 352x55 C LD HF EP RVSS 1 0.042 13.7 26s 188

2847 L 324x14 T5 LD HF SP 2 0.061 9.9 4s+14d 178

2848 L 323x14 T5 LD HF SP 2 0.061 9.6 4s+14d 178

2849 L 324x14 T5 LD HF EP SP 1 0.030 5.45 32s 178

2850 L 323x14 T5 LD HF EP SP 1 0.030 5.3 32s 178

2857 L 324x18 HF SP 2 0.064 9.5 4s+14d 178

2860 L 324x14 T5 LD HF 2M 2 0.061 8.8 4s+15d 167

2861 L 323x14 T5 LD HF 2M 2 0.061 8.6 4s+15d 167

2862 L 324x14 T5 LD HF EP 2M 1 0.030 4.9 32s 167

2863 L 323x14 T5 LD HF EP 2M 1 0.030 4.8 32s 167

2864 L 324x14 T5 LD HF DA 2M 2 0.061 9.2 4s+15d 167

2865 L 324x14 T5 LD HF DA EP 2M 1 0.030 5.1 32s 167

2870 L 324x18 LD HF 2M 2 0.064 9.1 4s+15d 168

2871 L 324x18 LD HF EP 2M 1 0.031 5.05 32s 168

2872 L 324x14 T5 LD HF 2US 2 0.061 8.8 4s+15d 171

2873 L 323x14 T5 LD HF 2US 2 0.061 8.6 4s+15d 171

2874 L 324x14 T5 LD HF EP 2US 1 0.030 4.9 32s 171

2875 L 323x14 T5 LD HF EP 2US 1 0.030 4.8 32s 171

2876 L 324x14 T5 LD HF DA 2US 2 0.061 9.2 4s+15d 171

2877 L 324x14 T5 LD HF DA EP 2US 1 0.030 5.1 32s 171

2882 L 324x18 LD HF 2US 2 0.064 9.1 4s+15d 172

2883 L 324x18 LD HF EP 2US 1 0.031 5.05 32s 172

2884 L 324x14 T5 LD HF 3AO 2 0.061 8.8 4s+15d 175

2885 L 323x14 T5 LD HF 3AO 2 0.061 8.6 4s+15d 175

2886 L 324x14 T5 LD HF EP 3AO 1 0.030 4.9 32s 175

2887 L 323x14 T5 LD HF EP 3AO 1 0.030 4.8 32s 175

2888 L 324x14 T5 LD HF DA 3AO 2 0.061 9.2 4s+15d 175

2889 L 324x14 T5 LD HF DA EP 3AO 1 0.030 5.1 32s 175

2894 L 324x18 LD HF 3AO 2 0.064 9.1 4s+15d 176

2895 L 324x18 LD HF EP 3AO 1 0.031 5.05 32s 176

2914 L 324x14 T5 LD HF 2MG 2 0.061 8.8 4s+15d 169

2915 L 323x14 T5 LD HF 2MG 2 0.061 8.6 4s+15d 169

2916 L 324x14 T5 LD HF EP 2MG 1 0.030 4.9 32s 169

2917 L 323x14 T5 LD HF EP 2MG 1 0.030 4.8 32s 169

2918 L 324x14 T5 LD HF DA 2MG 2 0.061 9.2 4s+15d 169

2919 L 324x14 T5 LD HF DA EP 2MG 1 0.030 5.1 32s 169

Code ItemPacking

Pallets PagePcs m³ Kg

2930 L 324x14 T5 LD HF 2S 2 0.061 8.8 4s+15d 173

2931 L 323x14 T5 LD HF 2S 2 0.061 8.6 4s+15d 173

2932 L 324x14 T5 LD HF EP 2S 1 0.030 4.9 32s 173

2933 L 323x14 T5 LD HF EP 2S 1 0.030 4.8 32s 173

2934 L 324x14 T5 LD HF DA 2S 2 0.061 9.2 4s+15d 173

2935 L 324x14 T5 LD HF DA EP 2S 1 0.030 5.1 32s 173

2978 L 324x14 T5 LD HF SPA 2 0.064 9.5 4s+14d 177

2979 L 323x14 T5 LD HF SPA 2 0.064 9.2 4s+14d 177

2980 L 324x14 T5 LD HF EP SPA 1 0.030 5.25 30s 177

2981 L 323x14 T5 LD HF EP SPA 1 0.030 5.1 30s 177

3084 3F Dodeca 220 AC 1x18 CD HF 2MG 1 0.019 1.25 90s 145

3085 3F Dodeca 220 AC 1x26 CD HF 2MG 1 0.019 1.3 90s 145

3087 3F Dodeca 220 AC 2x18 CD HF 2MG 1 0.019 1.45 90s 145

3088 3F Dodeca 220 AC 2x26 CD HF 2MG 1 0.019 1.6 90s 145

3094 3F Dodeca 220 AC 1x18 CD HF EP 2MG 1 0.019 2.05 60s 145

3095 3F Dodeca 220 AC 1x26 CD HF EP 2MG 1 0.019 2.1 60s 145

3097 3F Dodeca 220 AC 2x18 CD HF EP 2MG 1 0.019 2.25 60s 145

3098 3F Dodeca 220 AC 2x26 CD HF EP 2MG 1 0.019 2.35 60s 145

3174 3F Dodeca 220 AC 1x26 CD HF 2MG VS 1 0.019 1.55 90s 146

3176 3F Dodeca 220 AC 2x18 CD HF 2MG VS 1 0.019 1.7 90s 146

3177 3F Dodeca 220 AC 2x26 CD HF 2MG VS 1 0.019 1.85 90s 146

3181 3F Dodeca 220 AC 1x26 CD HF EP 2MG VS 1 0.019 2.25 60s 146

3183 3F Dodeca 220 AC 2x18 CD HF EP 2MG VS 1 0.019 2.5 60s 146

3184 3F Dodeca 220 AC 2x26 CD HF EP 2MG VS 1 0.019 2.6 60s 146

3561 3F Dodeca 300 1x26 CD HF 2MG 1 0.022 2.3 60s 149

3562 3F Dodeca 300 1x32 CT HF 2MG 1 0.022 2.35 60s 149

3563 3F Dodeca 300 1x42 CT HF 2MG 1 0.022 2.4 60s 149

3566 3F Dodeca 300 2x26 CD HF 2MG 1 0.022 2.55 60s 149

3567 3F Dodeca 300 2x32 CT HF 2MG 1 0.022 2.65 60s 149

3568 3F Dodeca 300 2x42 CT HF 2MG 1 0.022 2.75 60s 149

3570 3F Dodeca 300 1x26 CD HF EP 2MG 1 0.026 3.2 45s 149

3571 3F Dodeca 300 1x32 CT HF EP 2MG 1 0.026 3.25 45s 149

3572 3F Dodeca 300 1x42 CT HF EP 2MG 1 0.026 3.35 45s 149

3575 3F Dodeca 300 2x26 CD HF EP 2MG 1 0.026 3.3 45s 149

3576 3F Dodeca 300 2x32 CT HF EP 2MG 1 0.026 3.4 45s 149

3577 3F Dodeca 300 2x42 CT HF EP 2MG 1 0.026 3.7 45s 149

3606 3F Dodeca 300 1x26 CD HF 2S 1 0.022 2.3 60s 150

3607 3F Dodeca 300 1x32 CT HF 2S 1 0.022 2.35 60s 150

3608 3F Dodeca 300 1x42 CT HF 2S 1 0.022 2.4 60s 150

3611 3F Dodeca 300 2x26 CD HF 2S 1 0.022 2.55 60s 150

3612 3F Dodeca 300 2x32 CT HF 2S 1 0.022 2.65 60s 150

3613 3F Dodeca 300 2x42 CT HF 2S 1 0.022 2.75 60s 150

3615 3F Dodeca 300 1x26 CD HF EP 2S 1 0.026 3.2 45s 150

3616 3F Dodeca 300 1x32 CT HF EP 2S 1 0.026 3.25 45s 150

3617 3F Dodeca 300 1x42 CT HF EP 2S 1 0.026 3.35 45s 150

3620 3F Dodeca 300 2x26 CD HF EP 2S 1 0.026 3.3 45s 150

3621 3F Dodeca 300 2x32 CT HF EP 2S 1 0.026 3.4 45s 150

3622 3F Dodeca 300 2x42 CT HF EP 2S 1 0.026 3.7 45s 150

3656 3F Dodeca 300 1x42 CT HF 2MG VS 1 0.022 2.75 60s 151

3658 3F Dodeca 300 1x42 CT HF EP 2MG VS 1 0.026 3.7 45s 151

3768 3F Dodeca 220 1x42 CT HF 2MG VS 1 0.019 1.85 90s 142

3770 3F Dodeca 220 1x42 CT HF EP 2MG VS 1 0.019 2.65 60s 142

3897 3F Dodeca 220 1x18 CD HF 2MG 1 0.019 1.45 90s 141

3898 3F Dodeca 220 1x26 CD HF 2MG 1 0.019 1.5 90s 141

Page 481: 3F Filippi  "General catalogue 2016"

478

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

3900 3F Dodeca 220 2x18 CD HF 2MG 1 0.019 1.65 90s 141

3901 3F Dodeca 220 2x26 CD HF 2MG 1 0.019 1.8 90s 141

3905 3F Dodeca 220 1x42 CT HF 2MG 1 0.019 1.6 90s 141

3907 3F Dodeca 220 1x18 CD HF EP 2MG 1 0.019 2.25 60s 141

3908 3F Dodeca 220 1x26 CD HF EP 2MG 1 0.019 2.3 60s 141

3910 3F Dodeca 220 2x18 CD HF EP 2MG 1 0.019 2.45 60s 141

3911 3F Dodeca 220 2x26 CD HF EP 2MG 1 0.019 2.55 60s 141

3915 3F Dodeca 220 1x42 CT HF EP 2MG 1 0.019 2.4 60s 141

3938 3F Dodeca 220 1x18 CD HF 2S 1 0.019 1.45 90s 142

3940 3F Dodeca 220 1x26 CD HF 2S 1 0.019 1.5 90s 142

3942 3F Dodeca 220 1x42 CT HF 2S 1 0.019 1.6 90s 142

3944 3F Dodeca 220 2x18 CD HF 2S 1 0.019 1.65 90s 142

3945 3F Dodeca 220 2x26 CD HF 2S 1 0.019 1.8 90s 142

3948 3F Dodeca 220 1x18 CD HF EP 2S 1 0.019 2.25 60s 142

3950 3F Dodeca 220 1x26 CD HF EP 2S 1 0.019 2.3 60s 142

3952 3F Dodeca 220 1x42 CT HF EP 2S 1 0.019 2.4 60s 142

3954 3F Dodeca 220 2x18 CD HF EP 2S 1 0.019 2.45 60s 142

3955 3F Dodeca 220 2x26 CD HF EP 2S 1 0.019 2.55 60s 142

4105 Fil 180 1x36 HF RFMG 1 0.021 4.5 60s 75

4106 Fil 180 1x58 HF RFMG 1 0.026 5.1 60s 75

4175 Fil 220 2x36 HF RFMG 1 0.026 4.8 48s 81

4176 Fil 220 2x58 HF RFMG 1 0.031 5.6 48s 81

4300 Fil 180 1x54 T5 HF RFMG 1 0.021 4.25 60s 74

4301 Fil 180 1x49 T5 HF RFMG 1 0.026 4.95 60s 74

4302 Fil 180 1x80 T5 HF RFMG 1 0.026 4.95 60s 74

4303 Fil 180 1+1x54 T5 HF RFMG 1 0.041 8.5 60s 74

4304 Fil 180 1+1x49 T5 HF RFMG 1 0.051 9.2 60s 74

4305 Fil 180 1+1x80 T5 HF RFMG 1 0.051 9.2 60s 74

4318 Fil 220 2x54 T5 HF RFMG 1 0.026 4.7 48s 80

4319 Fil 220 2x49 T5 HF RFMG 1 0.031 5.45 48s 80

4320 Fil 220 2x80 T5 HF RFMG 1 0.031 5.45 48s 80

4350 Fil 220 2x36 HF SP 1 0.026 5.3 48s 80

4351 Fil 220 2x58 HF SP 1 0.031 6.4 48s 80

4354 Fil 220 2x36 HF EP SP 1 0.026 6.3 48s 80

4355 Fil 220 2x58 HF EP SP 1 0.031 7.4 48s 80

4702 3F Quadro LED 100W DA CR SP IP43 1 0.084 12.3 12s 113

4952 L 350 R90 4x40 C LD HF DA 2 0.074 10.3 2s+15d 191

4953 L 350 R90 4x55 C LD HF DA 2 0.074 10.3 2s+15d 191

4972 L 350 R90 4x55 C LD HF DA CONC 2 0.074 10.3 2s+15d 191

5200 3F Linda 1x18 1 0.008 1.72 180s 323

5201 3F Linda 1x36 1 0.016 2.6 90s 323

5202 3F Linda 1x58 1 0.020 3.39 90s 323

5203 3F Linda 2x18 1 0.013 2.17 112s 323

5204 3F Linda 2x36 1 0.024 3.86 56s 323

5205 3F Linda 2x58 1 0.030 5.16 56s 323

5206 3F Linda 1x18 LA 1 0.013 2 112s 323

5207 3F Linda 1x36 LA 1 0.024 2.9 56s 323

5208 3F Linda 1x58 LA 1 0.030 3.91 56s 323

5210 3F Linda Inox 1x18 AR 1 0.008 1.94 180s 323

5211 3F Linda Inox 1x36 AR 1 0.016 2.84 90s 323

5212 3F Linda Inox 1x58 AR 1 0.020 3.84 90s 323

5213 3F Linda Inox 2x18 AR 1 0.013 2.42 112s 323

5214 3F Linda Inox 2x36 AR 1 0.024 4.35 56s 323

5215 3F Linda Inox 2x58 AR 1 0.030 5.94 56s 323

Code ItemPacking

Pallets PagePcs m³ Kg

5220 3F Linda Inox 1x18 HF 1 0.008 1.42 180s 324

5221 3F Linda Inox 1x36 HF 1 0.016 2.32 90s 324

5222 3F Linda Inox 1x58 HF 1 0.020 2.82 90s 324

5223 3F Linda Inox 2x18 HF 1 0.013 1.92 112s 324

5224 3F Linda Inox 2x36 HF 1 0.024 3.1 56s 324

5225 3F Linda Inox 2x58 HF 1 0.030 3.78 56s 324

5230 3F Linda Industria 1x58 ENP 1 0.030 4.68 56s 329

5231 3F Linda Industria 1x58 EP 1 0.030 5.64 56s 328

5235 3F Linda 1x18 ENP 1 0.013 1.98 112s 329

5236 3F Linda 1x18 EP 1 0.013 2.59 112s 328

5237 3F Linda 1x36 ENP 1 0.016 2.55 90s 329

5238 3F Linda 1x36 EP 1 0.016 3.15 90s 328

5239 3F Linda 1x58 EP 1 0.020 4.1 90s 328

5240 3F Linda 2x18 EP 1 0.013 2.64 112s 328

5241 3F Linda 2x36 EP 1 0.024 4.38 56s 328

5242 3F Linda 2x58 EP 1 0.030 5.8 56s 328

5245 3F Linda Inox 1x18 ENP 1 0.013 2 112s 329

5246 3F Linda Inox 1x18 AR EP 1 0.013 2.48 112s 328

5247 3F Linda Inox 1x36 AR EP 1 0.016 3.34 90s 328

5248 3F Linda Inox 1x58 AR EP 1 0.020 4.56 90s 328

5249 3F Linda Inox 2x18 AR EP 1 0.013 2.89 112s 328

5250 3F Linda Inox 2x36 AR EP 1 0.024 4.83 56s 328

5251 3F Linda Inox 2x58 AR EP 1 0.030 6.67 56s 328

5252 3F Linda Inox 1x36 HF EP 1 0.016 2.96 90s 328

5253 3F Linda Inox 1x58 HF EP 1 0.020 3.82 90s 328

5254 3F Linda Inox 2x18 HF EP 1 0.013 2.5 112s 328

5255 3F Linda Inox 2x36 HF EP 1 0.024 3.3 56s 328

5256 3F Linda Inox 2x58 HF EP 1 0.030 4.55 56s 328

5257 3F Linda 1x11C ENP 1 0.006 1.28 192s 329

5259 3F Linda 1+1x11C ENP 1 0.006 1.85 192s 329

5260 3F Linda 1x11C 1 0.004 1 288s 326

5261 3F Linda 1x11C LA 1 0.006 1.21 192s 326

5262 3F Linda 2x11C 1 0.006 1.63 192s 326

5265 3F Linda Inox 1x18 HF EP 1 0.013 1.95 112s 328

5267 3F Linda Inox 1x11C HF LA EP 1 0.006 1.5 192s 328

5268 3F Linda Inox 2x11C HF EP 1 0.006 1.7 192s 328

5275 3F Linda Inox 1x11C HF 1 0.004 .9 288s 326

5276 3F Linda Inox 1x11C HF LA 1 0.006 1.1 192s 326

5277 3F Linda Inox 2x11C HF 1 0.006 1.3 192s 326

5350 3F Linda Trasparente 1x18 HF 1 0.008 1.42 180s 331

5351 3F Linda Trasparente 1x36 HF 1 0.016 2.32 90s 331

5352 3F Linda Trasparente 1x58 HF 1 0.020 2.82 90s 331

5354 3F Linda Trasparente 2x36 HF 1 0.024 3.1 56s 331

5355 3F Linda Trasparente 2x58 HF 1 0.030 3.63 56s 331

5356 3F Linda Trasparente 1x11 C 1 0.004 1 288s 332

5357 3F Linda Trasparente 2x11 C 1 0.006 1.63 192s 332

5358 3F Linda Trasparente 1x11C HF LA 1 0.006 1.1 192s 332

5359 3F Linda Trasparente 1x11C HF 1 0.004 .9 288s 332

5360 3F Linda Trasparente 2x11C HF 1 0.006 1.3 192s 332

5361 3F Linda Trasparente 1x14 T5 HF 1 0.008 1.4 180s 331

5363 3F Linda Trasparente 1x28 T5 HF 1 0.016 2.3 90s 331

5365 3F Linda Trasparente 1x49 T5 HF 1 0.020 2.8 90s 331

5374 3F Linda Trasparente 2x28 T5 HF 1 0.024 3.1 56s 331

5376 3F Linda Trasparente 2x49 T5 HF 1 0.030 3.6 56s 331

Page 482: 3F Filippi  "General catalogue 2016"

479

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

5391 3F Linda Trasparente 2x35 T5 LD HF UGR19 1 0.030 4 56s 332

5406 i3F 751x36 HF AMPIO 1 0.042 5.45 31s 355

5407 i3F 751x58 HF AMPIO 1 0.052 7.3 31s 355

5408 i3F 752x36 HF AMPIO 1 0.042 6.2 31s 355

5409 i3F 752x58 HF AMPIO 1 0.052 7.5 31s 355

5426 i3F 761x36 HF AMPIO 1 0.031 8.34 42s 357

5427 i3F 761x58 HF AMPIO 1 0.039 10.13 42s 357

5428 i3F 762x36 HF AMPIO 1 0.031 8.45 42s 357

5429 i3F 762x58 HF AMPIO 1 0.039 10.47 42s 357

5446 A3F 901x36 HF AMPIO 1 0.031 5.15 42s 361

5447 A3F 901x58 HF AMPIO 1 0.039 6.35 42s 361

5448 A3F 902x36 HF AMPIO 1 0.031 5.66 42s 361

5449 A3F 902x58 HF AMPIO 1 0.039 6.85 42s 361

5466 A3F 911x36 HF AMPIO 1 0.031 7.64 42s 363

5467 A3F 911x58 HF AMPIO 1 0.039 9.53 42s 363

5468 A3F 912x36 HF AMPIO 1 0.031 8.15 42s 363

5469 A3F 912x58 HF AMPIO 1 0.039 10.23 42s 363

5700 3F Linda Inox 1x14 T5 HF 1 0.008 1.47 180s 325

5702 3F Linda Inox 1x28 T5 HF 1 0.016 2.42 90s 325

5704 3F Linda Inox 1x35 T5 HF 1 0.020 2.97 90s 325

5705 3F Linda Inox 1x49 T5 HF 1 0.020 2.97 90s 325

5706 3F Linda Inox 1x80 T5 HF 1 0.020 2.97 90s 325

5707 3F Linda Inox 2x14 T5 HF 1 0.013 2.02 112s 325

5709 3F Linda Inox 2x28 T5 HF 1 0.024 3.3 56s 325

5711 3F Linda Inox 2x35 T5 HF 1 0.030 4.08 56s 325

5712 3F Linda Inox 2x49 T5 HF 1 0.030 4.08 56s 325

5720 3F Linda Inox 1x80 T5 HF LA CONC 1 0.030 3.7 56s 325

5741 3F Linda Inox 1x49 T5 HF EP 1 0.020 3.95 90s 328

5749 3F Linda Inox 2x49 T5 HF EP 1 0.030 4.68 56s 328

5764 3F Linda Inox 1x80 T5 HF LA EP CONC 1 0.030 5.1 56s 328

5768 3F Linda Inox 1x28-54 T5 HF 1 0.016 2.32 90s 325

5769 3F Linda Inox 1x35-49-80 T5 HF 1 0.020 2.82 90s 325

5772 3F Linda Inox 2x35-49 T5 HF 1 0.030 3.78 56s 325

5790 3F Linda Compatta LED 1x5W 100x300 1 0.004 .9 192s 308

5791 3F Linda Compatta LED 1x5W 160x300 1 0.006 1 192s 308

5796 i3F 751x18 HF 1 0.017 3.3 80s 355

5797 i3F 752x18 HF 1 0.017 3.5 80s 355

5808 i3F 751x58 HF CONC 1 0.042 7.2 31s 355

5809 i3F 752x58 HF CONC 1 0.052 7.3 31s 355

5811 i3F 752x36 HF EP AMPIO 1 0.042 6.8 31s 355

5812 i3F 752x58 HF EP AMPIO 1 0.052 8.1 31s 355

5817 i3F 761x18 HF 1 0.017 4.6 80s 357

5818 i3F 762x18 HF 1 0.017 4.9 80s 357

5821 i3F 761x58 HF CONC 1 0.039 10.1 42s 357

5822 i3F 762x58 HF CONC 1 0.039 10.5 42s 357

5844 i3F 762x36 HF EP AMPIO 1 0.031 9.05 42s 357

5845 i3F 762x58 HF EP AMPIO 1 0.039 11 42s 357

5847 A3F 901x18 HF 1 0.017 3 80s 361

5848 A3F 902x18 HF 1 0.017 3.25 80s 361

5859 A3F 901x58 HF CONC 1 0.039 5.7 42s 361

5860 A3F 902x58 HF CONC 1 0.039 5.8 42s 361

5866 A3F 902x36 HF EP AMPIO 1 0.031 6.3 42s 361

5867 A3F 902x58 HF EP AMPIO 1 0.039 7.45 42s 361

5868 A3F 911x18 HF 1 0.017 4.3 80s 363

Code ItemPacking

Pallets PagePcs m³ Kg

5869 A3F 912x18 HF 1 0.017 4.5 80s 363

5872 A3F 911x58 HF CONC 1 0.039 9.1 42s 363

5873 A3F 912x58 HF CONC 1 0.039 9.2 42s 363

5884 A3F 912x36 HF EP AMPIO 1 0.031 8.75 80s 363

5885 A3F 912x58 HF EP AMPIO 1 0.039 10.83 80s 363

5893 A3F 921x18 HF 1 0.017 3.35 80s 367

5894 A3F 922x18 HF 1 0.017 3.55 80s 367

5897 A3F 921x36 HF AMPIO 1 0.031 5.6 42s 367

5898 A3F 921x58 HF AMPIO 1 0.039 6.6 42s 367

5899 A3F 922x36 HF AMPIO 1 0.031 5.7 42s 367

5900 A3F 922x58 HF AMPIO 1 0.039 6.7 42s 367

5902 A3F 922x36 HF EP AMPIO 1 0.031 6.1 42s 367

5903 A3F 922x58 HF EP AMPIO 1 0.039 7.5 42s 367

5975 A3F 921x58 HF CONC 1 0.039 6.6 42s 367

5976 A3F 922x58 HF CONC 1 0.039 6.7 42s 367

8330 3F FS PC LED 1x4W-350 AM II 2 0.061 7.6 36s 395

8357 3F 66 1 LED 6 II 2 0.015 6 75s 393

8358 3F 66 2 LED 12 II 2 0.015 6.6 75s 393

8366 3F Metro 1 LED 8 AMPIO II 2 0.095 10 12s 397

9146 LUCECURA 1x35-49-80 Ind + 1x14-24 DX Dir T5 HF 1 0.074 407

9147 LUCECURA 1x35-49-80 Ind + 1x14-24 SX Dir T5 HF 1 0.074 407

9150 LUCECURA 2x35-49-80 Ind + 1x14-24 DX Dir T5 HF 1 0.074 407

9151 LUCECURA 2x35-49-80 Ind + 1x14-24 SX Dir T5 HF 1 0.074 407

9154 LUCECURA 3x35-49-80 Ind + 1x14-24 DX Dir T5 HF 1 0.074 407

9155 LUCECURA 3x35-49-80 Ind + 1x14-24 SX Dir T5 HF 1 0.074 407

9210 3F Relax 1000 1x39 Ind + 1x39 Dir T5 LD HF 1 0.020 7 405

9238 3F Relax 1500 1x49 Ind + 1+1x14W Dir T5 LD HF 1 0.042 13 405

9239 3F Relax 1800 1x49 Ind + 1+1x14W Dir T5 LD HF 1 0.029 13 405

10025 P 201x18 HF 2M 1 0.009 2.75 120s 103

10026 P 201x36 HF 2M 1 0.018 4 60s 103

10027 P 201x58 HF 2M 1 0.024 4.75 60s 103

10028 P 202x18 HF ST 2M 1 0.012 3.2 96s 103

10029 P 202x36 HF ST 2M 1 0.023 4.4 48s 103

10030 P 202x58 HF ST 2M 1 0.030 5.6 48s 103

10031 P 202x36 HF 2M 1 0.031 5.7 33s 103

10032 P 202x58 HF 2M 1 0.041 6.54 33s 103

10033 P 203x18 HF 2M 1 0.037 6.2 30s 103

10034 P 204x18 HF 2M 1 0.037 5.48 30s 103

10085 P 201x18 HF 2US 1 0.009 2.75 120s 105

10086 P 201x36 HF 2US 1 0.018 4 60s 105

10087 P 201x58 HF 2US 1 0.024 4.75 60s 105

10088 P 202x18 HF ST 2US 1 0.012 3.2 96s 105

10089 P 202x36 HF ST 2US 1 0.023 4.4 48s 105

10090 P 202x58 HF ST 2US 1 0.030 5.6 48s 105

10091 P 202x36 HF 2US 1 0.031 5.7 33s 105

10092 P 202x58 HF 2US 1 0.041 6.54 33s 105

10093 P 203x18 HF 2US 1 0.037 6.2 30s 105

10094 P 204x18 HF 2US 1 0.037 5.48 30s 105

10265 P 201x18 HF 2MG 1 0.009 2.75 120s 104

10266 P 201x36 HF 2MG 1 0.018 4 60s 104

10267 P 201x58 HF 2MG 1 0.024 4.75 60s 104

10268 P 202x18 HF ST 2MG 1 0.012 3.2 96s 104

10269 P 202x36 HF ST 2MG 1 0.023 4.4 48s 104

10270 P 202x58 HF ST 2MG 1 0.030 5.6 48s 104

Page 483: 3F Filippi  "General catalogue 2016"

480

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

10271 P 202x36 HF 2MG 1 0.031 5.7 33s 104

10272 P 202x58 HF 2MG 1 0.041 6.54 33s 104

10273 P 203x18 HF 2MG 1 0.037 6.2 30s 104

10274 P 204x18 HF 2MG 1 0.037 5.48 30s 104

10546 P 202x28-54 T5 HF RVS IP54 1 0.031 8.65 33s 107

10548 P 204x14-24 T5 HF DA RVS IP54 1 0.037 9.6 30s 107

10572 P 202x28-54 T5 HF RSP IP54 1 0.031 7 33s 107

10574 P 204x14-24 T5 HF DA RSP IP54 1 0.037 7.76 30s 107

10704 3F Travetta LED 1x22W 2MG L1590 1 0.022 4.8 75s 43

10707 3F Travetta LED 2x22W 2MG L1590 1 0.022 5 75s 43

10718 3F Travetta LED 1x22W SP L1590 1 0.022 4.8 75s 44

10721 3F Travetta LED 2x22W SP L1590 1 0.022 5 75s 44

10732 3F Travetta LED 1x22W OP L1590 1 0.022 4.8 75s 43

10735 3F Travetta LED 2x22W OP L1590 1 0.022 5 75s 43

10747 3F Travetta LED DI 2x15W 2MG L1590 1 0.022 5.2 75s 47

10748 3F Travetta LED DI 2x22W 2MG L1590 1 0.022 5.2 75s 47

10763 3F Travetta LED 2x22W DALI HCL 2MG L1590 1 0.022 6.5 75s 49

10771 3F Travetta LED 1x40W SP L2200 1 0.030 7 75s 44

10773 3F Travetta LED 2x40W SP L2200 1 0.030 7.5 75s 44

10775 3F Travetta LED 1x40W OP L2200 1 0.030 7 75s 43

10777 3F Travetta LED 2x40W OP L2200 1 0.030 7.5 75s 43

10870 3F Zeta D 1x22 LED L1489 1 0.019 4 168s 11

10871 3F Zeta D 1x18 LED L1194 1 0.019 3.5 168s 11

10872 3F Zeta D 1x9 LED L605 1 0.019 2.8 168s 11

10873 3F Zeta D 2x22 LED L1489 1 0.019 4.2 168s 11

10874 3F Zeta D 2x18 LED L1194 1 0.019 3.7 168s 11

10875 3F Zeta D 2x9 LED L605 1 0.019 3 168s 11

10877 3F Zeta DR 1x22 LED L1489 1 0.019 4 168s 13

10878 3F Zeta DR 1x18 LED L1194 1 0.019 3.5 168s 13

10879 3F Zeta DR 1x9 LED L605 1 0.019 2.8 168s 13

10880 3F Zeta DR 2x22 LED L1489 1 0.019 4.2 168s 13

10881 3F Zeta DR 2x18 LED L1194 1 0.019 3.7 168s 13

10882 3F Zeta DR 2x9 LED L605 1 0.019 3 168s 13

10886 3F Zeta DR AS 1x30 LED L1489 1 0.019 4.5 168s 13

10887 3F Zeta DR AS 2x22 LED L1489 1 0.019 4.7 168s 13

10892 3F Zeta L 40 LED L1489 1 0.019 4 168s 9

10893 3F Zeta L 30 LED L1194 1 0.019 3.5 168s 9

10894 3F Zeta L 15 LED L605 1 0.019 2.8 168s 9

11006 Fil 180 1x28 T5 HF 2M 1 0.021 4.25 60s 69

11007 Fil 180 1x35 T5 HF 2M 1 0.026 5.05 60s 69

11008 Fil 180 1+1x28 T5 HF 2M 1 0.041 7.5 60s 69

11009 Fil 180 1+1x35 T5 HF 2M 1 0.051 9.3 60s 69

11011 Fil 180 2x28 T5 HF 2M 1 0.021 4.4 60s 69

11012 Fil 180 2x35 T5 HF 2M 1 0.026 5.2 60s 69

11013 Fil 180 2+2x28 T5 HF 2M 1 0.041 8.1 60s 69

11014 Fil 180 2+2x35 T5 HF 2M 1 0.051 9.9 60s 69

11016 Fil 180 1x28 T5 HF EP 2M 1 0.021 4.95 60s 69

11017 Fil 180 1x35 T5 HF EP 2M 1 0.026 6.05 60s 69

11021 Fil 180 2x28 T5 HF EP 2M 1 0.021 5.1 60s 69

11022 Fil 180 2x35 T5 HF EP 2M 1 0.026 6.2 60s 69

11046 Fil 180 1x36 HF 2M 1 0.021 4.6 60s 70

11047 Fil 180 1x58 HF 2M 1 0.026 5.2 60s 70

11051 Fil 180 1x36 HF EP 2M 1 0.021 5.25 60s 70

11052 Fil 180 1x58 HF EP 2M 1 0.026 5.9 60s 70

Code ItemPacking

Pallets PagePcs m³ Kg

11066 Fil 180 1x28 T5 HF 2MG 1 0.021 4.25 60s 70

11067 Fil 180 1x35 T5 HF 2MG 1 0.026 5.05 60s 70

11068 Fil 180 1+1x28 T5 HF 2MG 1 0.041 7.5 60s 70

11069 Fil 180 1+1x35 T5 HF 2MG 1 0.051 9.3 60s 70

11071 Fil 180 2x28 T5 HF 2MG 1 0.021 4.4 60s 70

11072 Fil 180 2x35 T5 HF 2MG 1 0.026 5.2 60s 70

11073 Fil 180 2+2x28 T5 HF 2MG 1 0.041 8.1 60s 70

11074 Fil 180 2+2x35 T5 HF 2MG 1 0.051 9.9 60s 70

11106 Fil 180 1x36 HF 2MG 1 0.021 4.6 60s 71

11107 Fil 180 1x58 HF 2MG 1 0.026 5.2 60s 71

11126 Fil 180 1x28 T5 HF 2US 1 0.021 4.25 60s 71

11127 Fil 180 1x35 T5 HF 2US 1 0.026 5.05 60s 71

11128 Fil 180 1+1x28 T5 HF 2US 1 0.041 7.5 60s 71

11129 Fil 180 1+1x35 T5 HF 2US 1 0.051 9.3 60s 71

11131 Fil 180 2x28 T5 HF 2US 1 0.021 4.4 60s 71

11132 Fil 180 2x35 T5 HF 2US 1 0.026 5.2 60s 71

11133 Fil 180 2+2x28 T5 HF 2US 1 0.041 8.1 60s 71

11134 Fil 180 2+2x35 T5 HF 2US 1 0.051 9.9 60s 71

11136 Fil 180 1x28 T5 HF EP 2US 1 0.021 4.95 60s 71

11137 Fil 180 1x35 T5 HF EP 2US 1 0.026 6.05 60s 71

11141 Fil 180 2x28 T5 HF EP 2US 1 0.021 5.1 60s 71

11142 Fil 180 2x35 T5 HF EP 2US 1 0.026 6.2 60s 71

11166 Fil 180 1x36 HF 2US 1 0.021 4.6 60s 72

11167 Fil 180 1x58 HF 2US 1 0.026 5.2 60s 72

11171 Fil 180 1x36 HF EP 2US 1 0.021 5.25 60s 72

11172 Fil 180 1x58 HF EP 2US 1 0.026 5.9 60s 72

11306 Fil 180 1x28 T5 HF 3AO 1 0.021 4.25 60s 73

11307 Fil 180 1x35 T5 HF 3AO 1 0.026 5.05 60s 73

11308 Fil 180 1+1x28 T5 HF 3AO 1 0.041 7.5 60s 73

11309 Fil 180 1+1x35 T5 HF 3AO 1 0.051 9.3 60s 73

11311 Fil 180 2x28 T5 HF 3AO 1 0.021 4.4 60s 73

11312 Fil 180 2x35 T5 HF 3AO 1 0.026 5.2 60s 73

11313 Fil 180 2+2x28 T5 HF 3AO 1 0.041 8.1 60s 73

11314 Fil 180 2+2x35 T5 HF 3AO 1 0.051 9.9 60s 73

11316 Fil 180 1x28 T5 HF EP 3AO 1 0.021 4.95 60s 73

11317 Fil 180 1x35 T5 HF EP 3AO 1 0.026 6.05 60s 73

11321 Fil 180 2x28 T5 HF EP 3AO 1 0.021 5.1 60s 73

11322 Fil 180 2x35 T5 HF EP 3AO 1 0.026 6.2 60s 73

11346 Fil 180 1x36 HF 3AO 1 0.021 4.6 60s 74

11347 Fil 180 1x58 HF 3AO 1 0.026 5.2 60s 74

11351 Fil 180 1x36 HF EP 3AO 1 0.021 5.25 60s 74

11352 Fil 180 1x58 HF EP 3AO 1 0.026 5.9 60s 74

11726 Fil 220 2x28 T5 HF 2M 1 0.026 4.8 48s 77

11727 Fil 220 2x35 T5 HF 2M 1 0.031 5.55 48s 77

11731 Fil 220 2x28 T5 HF EP 2M 1 0.026 5.55 48s 77

11732 Fil 220 2x35 T5 HF EP 2M 1 0.031 6.55 48s 77

11756 Fil 220 2x36 HF 2M 1 0.026 4.9 48s 77

11757 Fil 220 2x58 HF 2M 1 0.031 5.7 48s 77

11761 Fil 220 2x36 HF EP 2M 1 0.026 5.55 48s 77

11762 Fil 220 2x58 HF EP 2M 1 0.031 6.4 48s 77

11826 Fil 220 2x28 T5 HF 2US 1 0.026 4.8 48s 78

11827 Fil 220 2x35 T5 HF 2US 1 0.031 5.55 48s 78

11831 Fil 220 2x28 T5 HF EP 2US 1 0.026 5.55 48s 78

11832 Fil 220 2x35 T5 HF EP 2US 1 0.031 6.55 48s 78

Page 484: 3F Filippi  "General catalogue 2016"

481

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

11856 Fil 220 2x36 HF 2US 1 0.026 4.9 48s 78

11857 Fil 220 2x58 HF 2US 1 0.031 5.7 48s 78

11861 Fil 220 2x36 HF EP 2US 1 0.026 5.55 48s 78

11862 Fil 220 2x58 HF EP 2US 1 0.031 6.4 48s 78

11976 Fil 220 2x28 T5 HF 3AO 1 0.026 4.8 48s 79

11977 Fil 220 2x35 T5 HF 3AO 1 0.031 5.55 48s 79

11981 Fil 220 2x28 T5 HF EP 3AO 1 0.026 5.55 48s 79

11982 Fil 220 2x35 T5 HF EP 3AO 1 0.031 6.55 48s 79

12006 Fil 220 2x36 HF 3AO 1 0.026 4.9 48s 79

12007 Fil 220 2x58 HF 3AO 1 0.031 5.7 48s 79

12011 Fil 220 2x36 HF EP 3AO 1 0.026 5.55 48s 79

12012 Fil 220 2x58 HF EP 3AO 1 0.031 6.4 48s 79

12120 Fly2 LED B 2x24W DALI SP L1316 1 0.032 6.5 43s 89

12403 Fil 180 LED 2x24W RSP AMPIO L1280 1 0.021 5 60s 67

12404 Fil 180 LED 2x30W RSP AMPIO L1590 1 0.026 6.2 60s 67

12491 03F LED 1x9W L640 1 0.006 1.5 180s 109

12493 03F LED 1x18W L1250 1 0.012 3 90s 109

12495 03F LED 1x22W L1550 1 0.014 4.5 90s 109

12501 03F LED 2x9W L640 1 0.012 2.2 120s 109

12503 03F LED 2x18W L1250 1 0.023 4 60s 109

12505 03F LED 2x22W L1550 1 0.028 5.8 60s 109

12507 03F LED 4x6W 350x350 1 0.011 2 108s 109

12508 03F LED 4x9W 640x640 1 0.034 3.8 35s 109

12601 Fil 180 LED 1x24W 2US L1280 1 0.021 4.5 60s 67

12603 Fil 180 LED 1x30W 2US L1590 1 0.026 5.7 60s 67

12605 Fil 180 LED 2x24W 2US L1280 1 0.021 4.7 60s 67

12607 Fil 180 LED 2x30W 2US L1590 1 0.026 5.9 60s 67

12614 Fil 180 LED 1+1x30W 2US L3140 1 0.051 11.4 60s 67

12618 Fil 180 LED 2+2x30W 2US L3140 1 0.051 11.8 60s 67

12675 P 201x30W LED 2US 156x1531 1 0.024 4.9 60s 99

12680 P 202x24W LED 2US 196x1231 1 0.023 4.5 48s 99

12682 P 202x30W LED 2US 196x1531 1 0.030 5.8 48s 99

12687 P 202x24W LED 2US 270x1231 1 0.031 5.9 33s 99

12689 P 202x30W LED 2US 270x1531 1 0.041 6.7 33s 99

12692 P 203x10W LED 2US 596x596 1 0.037 5.3 30s 99

12703 P 201x30W LED SP 156x1531 1 0.024 5.2 60s 99

12708 P 202x24W LED SP 196x1231 1 0.023 4.7 48s 99

12710 P 202x30W LED SP 196x1531 1 0.030 6 48s 99

12720 P 203x10W LED SP 596x596 1 0.037 5.5 30s 99

12722 P 204x10W LED SP 596x596 1 0.037 5.6 30s 99

12731 P 201x30W LED OP 156x1531 1 0.024 5.2 60s 100

12736 P 202x24W LED OP 196x1231 1 0.023 4.7 48s 100

12738 P 202x30W LED OP 196x1531 1 0.030 6 48s 100

12748 P 203x10W LED OP 596x596 1 0.037 5.5 30s 100

12750 P 204x10W LED OP 596x596 1 0.037 5.6 30s 100

12771 Barraluce P 1x30W LED SP L1471 1 0.050 4.6 70s 116

12773 Barraluce P 1+1x30W LED SP L2937 1 0.050 9.2 70s 116

12779 Barraluce P 1x30W LED SP 5P L1466 1 0.050 4.9 70s 116

12781 Barraluce P 1+1x30W LED SP 5P L2932 1 0.050 9.8 70s 116

12787 Barraluce P 1x30W LED OP L1471 1 0.050 4.6 70s 115

12789 Barraluce P 1+1x30W LED OP L2937 1 0.050 9.2 70s 115

12795 Barraluce P 1x30W LED OP 5P L1466 1 0.050 4.9 70s 115

12797 Barraluce P 1+1x30W LED OP 5P L2932 1 0.050 9.2 70s 115

13002 3F Travetta GR DI 1x35 T5 LD HF 2MG 1 0.022 4.7 75s 57

Code ItemPacking

Pallets PagePcs m³ Kg

13004 3F Travetta GR DI 1x54 T5 LD HF 2MG 1 0.018 3.9 75s 57

13005 3F Travetta GR DI 1x49 T5 LD HF 2MG 1 0.022 4.7 75s 57

13008 3F Travetta GR DI 2x28 T5 LD HF 2MG 1 0.018 4.1 75s 57

13009 3F Travetta GR DI 2x35 T5 LD HF 2MG 1 0.022 4.95 75s 57

13077 3F Travetta GR DI 1x28-54 T5 HF 2MG AMPIA 1 0.018 3.9 75s 57

13078 3F Travetta GR DI 1x35-49-80T5 HF 2MG AM 1 0.022 4.7 75s 57

13080 3F Travetta GR DI 2x28-54 T5 HF 2MG AMPIA 1 0.018 3.9 75s 57

13081 3F Travetta GR DI 2x35-49 T5 HF 2MG AMPIA 1 0.022 4.7 75s 57

13085 3F Travetta GR 1x14 T5 LD HF 2MG 1 0.010 2.3 150s 51

13087 3F Travetta GR 1x35 T5 LD HF 2MG 1 0.022 5.2 75s 51

13088 3F Travetta GR 1x24 T5 LD HF 2MG 1 0.010 2.3 150s 51

13089 3F Travetta GR 1x54 T5 LD HF 2MG 1 0.018 4.3 75s 51

13090 3F Travetta GR 1x49 T5 LD HF 2MG 1 0.022 5.2 75s 51

13091 3F Travetta GR 1x80 T5 LD HF 2MG 1 0.022 5.2 75s 51

13092 3F Travetta GR 2x14 T5 LD HF 2MG 1 0.010 2.5 150s 51

13093 3F Travetta GR 2x28 T5 LD HF 2MG 1 0.018 4.5 75s 51

13094 3F Travetta GR 2x35 T5 LD HF 2MG 1 0.022 5.45 75s 51

13095 3F Travetta GR 2x24 T5 LD HF 2MG 1 0.010 2.5 150s 51

13162 3F Travetta GR 1x28-54 T5 HF 2MG AMPIA 1 0.018 4.3 75s 52

13163 3F Travetta GR 1x35-49-80 T5 HF 2MG AMPIA 1 0.022 5.15 75s 52

13165 3F Travetta GR 2x28-54 T5 HF 2MG AMPIA 1 0.018 4.3 75s 52

13166 3F Travetta GR 2x35-49 T5 HF 2MG AMPIA 1 0.022 5.15 75s 52

13172 3F Travetta DI 1x35 T5 LD HF 2MG 1 0.022 4.7 75s 57

13174 3F Travetta DI 1x54 T5 LD HF 2MG 1 0.018 3.9 75s 57

13175 3F Travetta DI 1x49 T5 LD HF 2MG 1 0.022 4.7 75s 57

13178 3F Travetta DI 2x28 T5 LD HF 2MG 1 0.018 4.1 75s 57

13179 3F Travetta DI 2x35 T5 LD HF 2MG 1 0.022 4.95 75s 57

13255 3F Travetta 1x14 T5 LD HF 2MG 1 0.010 2.3 150s 51

13257 3F Travetta 1x35 T5 LD HF 2MG 1 0.022 5.2 75s 51

13258 3F Travetta 1x24 T5 LD HF 2MG 1 0.010 2.3 150s 51

13259 3F Travetta 1x54 T5 LD HF 2MG 1 0.018 4.3 75s 51

13260 3F Travetta 1x49 T5 LD HF 2MG 1 0.022 5.2 75s 51

13261 3F Travetta 1x80 T5 LD HF 2MG 1 0.022 5.2 75s 51

13262 3F Travetta 2x14 T5 LD HF 2MG 1 0.010 2.5 150s 51

13263 3F Travetta 2x28 T5 LD HF 2MG 1 0.018 4.5 75s 51

13264 3F Travetta 2x35 T5 LD HF 2MG 1 0.022 5.45 75s 51

13265 3F Travetta 2x24 T5 LD HF 2MG 1 0.010 2.5 150s 51

13342 3F Travetta GR DI 1x35 T5 LD HF 2S 1 0.022 4.7 75s 58

13344 3F Travetta GR DI 1x54 T5 LD HF 2S 1 0.018 3.9 75s 58

13345 3F Travetta GR DI 1x49 T5 LD HF 2S 1 0.022 4.7 75s 58

13348 3F Travetta GR DI 2x28 T5 LD HF 2S 1 0.018 4.1 75s 58

13349 3F Travetta GR DI 2x35 T5 LD HF 2S 1 0.022 4.95 75s 58

13425 3F Travetta GR 1x14 T5 LD HF 2S 1 0.010 2.3 150s 53

13427 3F Travetta GR 1x35 T5 LD HF 2S 1 0.022 5.2 75s 53

13428 3F Travetta GR 1x24 T5 LD HF 2S 1 0.010 2.3 150s 53

13429 3F Travetta GR 1x54 T5 LD HF 2S 1 0.018 4.3 75s 53

13430 3F Travetta GR 1x49 T5 LD HF 2S 1 0.022 5.2 75s 53

13431 3F Travetta GR 1x80 T5 LD HF 2S 1 0.022 5.2 75s 53

13432 3F Travetta GR 2x14 T5 LD HF 2S 1 0.010 2.5 150s 53

13433 3F Travetta GR 2x28 T5 LD HF 2S 1 0.018 4.5 75s 53

13434 3F Travetta GR 2x35 T5 LD HF 2S 1 0.022 5.45 75s 53

13435 3F Travetta GR 2x24 T5 LD HF 2S 1 0.010 2.5 150s 53

13512 3F Travetta DI 1x35 T5 LD HF 2S 1 0.022 4.7 75s 58

13514 3F Travetta DI 1x54 T5 LD HF 2S 1 0.018 3.9 75s 58

Page 485: 3F Filippi  "General catalogue 2016"

482

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

13515 3F Travetta DI 1x49 T5 LD HF 2S 1 0.022 4.7 75s 58

13518 3F Travetta DI 2x28 T5 LD HF 2S 1 0.018 4.1 75s 58

13519 3F Travetta DI 2x35 T5 LD HF 2S 1 0.022 4.95 75s 58

13595 3F Travetta 1x14 T5 LD HF 2S 1 0.010 2.3 150s 53

13597 3F Travetta 1x35 T5 LD HF 2S 1 0.022 5.2 75s 53

13598 3F Travetta 1x24 T5 LD HF 2S 1 0.010 2.3 150s 53

13599 3F Travetta 1x54 T5 LD HF 2S 1 0.018 4.1 75s 53

13600 3F Travetta 1x49 T5 LD HF 2S 1 0.022 5.2 75s 53

13601 3F Travetta 1x80 T5 LD HF 2S 1 0.022 5.2 75s 53

13602 3F Travetta 2x14 T5 LD HF 2S 1 0.010 2.5 150s 53

13603 3F Travetta 2x28 T5 LD HF 2S 1 0.018 4.5 75s 53

13604 3F Travetta 2x35 T5 LD HF 2S 1 0.022 5.45 75s 53

13605 3F Travetta 2x24 T5 LD HF 2S 1 0.010 2.5 150s 53

14877 3F Travetta 1x28-54 T5 HF DALI 2MG AMPIA 1 0.018 3.9 75s 52

14878 3F Travetta 1x35-49-80 T5 HF DALI 2MG AM 1 0.022 5.15 75s 52

14879 3F Travetta 2x28-54 T5 HF DALI 2MG AMPIA 1 0.018 4.3 75s 52

14880 3F Travetta 2x35-49-80 T5 HF DALI 2MG AM 1 0.022 5.15 75s 52

14922 3F Travetta DI 1x28-54 T5 HF DALI 2MG AM 1 0.018 3.9 75s 58

14923 3F Trav. DI 1x35-49-80 T5 HF DALI 2MG AM 1 0.022 5.15 75s 58

14924 3F Travetta DI 2x28-54 T5 HF DALI 2MG AM 1 0.018 4.3 75s 58

14925 3F Trav.DI 2x35-49-80 T5 HF DALI 2MG AM 1 0.022 5.15 75s 58

15380 Fly2 B 2x28 T5 LD HF OP 1 0.032 6.4 43s 95

15381 Fly2 B 2x54 T5 LD HF OP 1 0.032 6.4 43s 95

15388 Fly2 B 4x49 T5 LD HF DA OP 1 0.039 8.2 43s 95

15426 Fly2 B 2x54 T5 LD HF SPM 1 0.032 7 43s 93

15428 Fly2 B 2x49 T5 LD HF SPM 1 0.039 8.2 43s 93

15433 Fly2 B 4x49 T5 LD HF DA SPM 1 0.039 9 43s 93

15441 Fly2 B 2x54 T5 LD HF EP SPM 1 0.032 7.8 43s 93

15470 Fly2 B 2x28 T5 LD HF SP 1 0.032 6.25 43s 94

15471 Fly2 B 2x54 T5 LD HF SP 1 0.032 6.25 43s 94

15478 Fly2 B 4x49 T5 LD HF DA SP 1 0.039 8 43s 94

15696 Fly2 GR 2x54 T5 LD HF SPM 1 0.032 7 43s 93

15698 Fly2 GR 2x49 T5 LD HF SPM 1 0.039 8.2 43s 93

15703 Fly2 GR 4x49 T5 LD HF DA SPM 1 0.039 9 43s 93

15711 Fly2 GR 2x54 T5 LD HF EP SPM 1 0.032 7.8 43s 93

15713 Fly2 GR 2x49 T5 LD HF EP SPM 1 0.039 9.2 43s 93

15740 Fly2 GR 2x28 T5 LD HF SP 1 0.032 6.25 43s 94

15741 Fly2 GR 2x54 T5 LD HF SP 1 0.032 6.25 43s 94

15748 Fly2 GR 4x49 T5 LD HF DA SP 1 0.039 8 43s 94

15896 Fly2 Piantana LED 5x10W SPM L717 1 0.040 23 91

16058 Fly2 B 2x54 T5 LD HF DALI SPM 1 0.032 7 43s 93

16060 Fly2 B 2x49 T5 LD HF DALI SPM 1 0.039 8.4 43s 93

16067 Fly2 B 4x49 T5 LD HF DALI SPM 1 0.039 9 43s 93

16142 Fly2 GR 2x54 T5 LD HF DALI SPM 1 0.032 7 43s 93

16144 Fly2 GR 2x49 T5 LD HF DALI SPM 1 0.039 8.4 43s 93

16151 Fly2 GR 4x49 T5 LD HF DALI SPM 1 0.039 9 43s 93

17479 Fly2 GR 2x49 T5 LD HF DALI SPM IFC 1 0.039 7.4 43s 94

19003 3F Travetta 1x35 T5 LD HF OP 1 0.022 4.5 75s 54

19005 3F Travetta 1x54 T5 LD HF OP 1 0.018 3.8 75s 54

19006 3F Travetta 1x49 T5 LD HF OP 1 0.022 4.5 75s 54

19009 3F Travetta 2x28 T5 LD HF OP 1 0.018 4.1 75s 54

19010 3F Travetta 2x35 T5 LD HF OP 1 0.022 4.8 75s 54

19088 3F Travetta GR 1x35 T5 LD HF OP 1 0.022 4.5 75s 54

19090 3F Travetta GR 1x54 T5 LD HF OP 1 0.018 3.8 75s 54

Code ItemPacking

Pallets PagePcs m³ Kg

19091 3F Travetta GR 1x49 T5 LD HF OP 1 0.022 4.5 75s 54

19094 3F Travetta GR 2x28 T5 LD HF OP 1 0.018 4.1 75s 54

19095 3F Travetta GR 2x35 T5 LD HF OP 1 0.022 4.8 75s 54

19173 3F Travetta DI 1x35 T5 LD HF OP 1 0.022 4.5 75s 59

19175 3F Travetta DI 1x54 T5 LD HF OP 1 0.018 3.8 75s 59

19176 3F Travetta DI 1x49 T5 LD HF OP 1 0.022 4.5 75s 59

19179 3F Travetta DI 2x28 T5 LD HF OP 1 0.018 4.1 75s 59

19180 3F Travetta DI 2x35 T5 LD HF OP 1 0.022 4.8 75s 59

19258 3F Travetta GR DI 1x35 T5 LD HF OP 1 0.022 4.5 75s 59

19260 3F Travetta GR DI 1x54 T5 LD HF OP 1 0.018 3.8 75s 59

19261 3F Travetta GR DI 1x49 T5 LD HF OP 1 0.022 4.5 75s 59

19264 3F Travetta GR DI 2x28 T5 LD HF OP 1 0.018 4.1 75s 59

19265 3F Travetta GR DI 2x35 T5 LD HF OP 1 0.022 4.8 75s 59

21002 L 324x14 T5 LD HF BA 2M 2 0.061 9.6 4s+15d 181

21003 L 323x14 T5 LD HF BA 2M 2 0.061 9.4 4s+15d 181

21010 L 324x14 T5 LD HF DA BA 2M 2 0.061 10 4s+15d 181

21114 L 321x18 HF 2M 1 0.014 2.5 100s 168

21115 L 322x18 HF 2M 1 0.019 3.1 66s 168

21116 L 321x36 HF 2M 1 0.027 4.3 49s 168

21117 L 322x36 HF 2M 1 0.037 5.3 33s 168

21118 L 323x36 HF 2M 1 0.077 9 14s 168

21119 L 324x36 HF 2M 1 0.077 9.5 14s 168

21124 L 322x36 HF 2MG 1 0.037 5.3 33s 170

21125 L 323x36 HF 2MG 1 0.077 9 14s 170

21126 L 324x36 HF 2MG 1 0.077 9.5 14s 170

21133 L 321x18 HF 2US 1 0.014 2.5 100s 172

21134 L 322x18 HF 2US 1 0.019 3.1 66s 172

21135 L 321x36 HF 2US 1 0.027 4.3 49s 172

21136 L 322x36 HF 2US 1 0.037 5.3 33s 172

21142 L 321x18 HF 2S 1 0.014 2.5 100s 174

21143 L 322x18 HF 2S 1 0.019 3.1 66s 174

21144 L 321x36 HF 2S 1 0.027 4.3 49s 174

21145 L 322x36 HF 2S 1 0.037 5.3 33s 174

21146 L 323x36 HF 2S 1 0.077 9 14s 174

21147 L 324x36 HF 2S 1 0.077 9.5 14s 174

21153 L 321x18 HF 3AO 1 0.014 2.5 100s 176

21154 L 322x18 HF 3AO 1 0.019 3.1 66s 176

21155 L 322x36 HF 3AO 1 0.037 5.3 33s 176

21156 L 324x36 HF 3AO 1 0.077 9.5 14s 176

21171 L 324x18 HF SPA 2 0.064 8.6 4s+14d 177

21172 L 323x18 HF SPA 2 0.064 8.4 4s+14d 177

21175 L 324x18 HF EP SPA 1 0.031 4.85 32s 177

21176 L 323x18 HF EP SPA 1 0.031 4.65 32s 177

21182 L 323x18 HF SP 2 0.064 8.6 4s+14d 178

21188 L 321x18 HF SP 1 0.014 2.8 100s 178

21189 L 322x18 HF SP 1 0.019 3.2 66s 178

21190 L 321x36 HF SP 1 0.027 4.9 49s 178

21191 L 322x36 HF SP 1 0.037 5.5 33s 178

21192 L 323x36 HF SP 1 0.077 9.6 14s 178

21193 L 324x36 HF SP 1 0.077 9.9 14s 178

21244 L 323x10W LED SP 596x596 1 0.030 5 32s 156

21245 L 324x10W LED SP 596x596 1 0.030 5.2 32s 156

21256 L 323x10W LED DALI SP 596x596 1 0.030 5 32s 156

21257 L 324x10W LED DALI SP 596x596 1 0.030 5.2 32s 156

Page 486: 3F Filippi  "General catalogue 2016"

483

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

21262 L 323x10W LED EP SP 596x596 1 0.030 5.9 32s 156

21263 L 324x10W LED EP SP 596x596 1 0.030 6.1 32s 156

21282 L 323x10W LED Sensor CF SP 596x596 1 0.030 5.2 32s 163

21287 L 322x18W LED SP 296x1196 1 0.037 5.4 33s 156

21290 L 322x18W LED DALI SP 296x1196 1 0.037 5.4 33s 156

21293 L 322x18W LED EP SP 296x1196 1 0.037 5.9 33s 156

21393 L 322x24W LED WW 296x1196 1 0.037 5.5 33s 165

21408 L 320 32W LED OP 596x596 1 0.030 5.1 32s 159

21410 L 320 32W LED DALI OP 596x596 1 0.030 5.1 32s 159

21422 L 320 32W LED LGS 596x596 1 0.030 5.1 32s 159

21424 L 320 32W LED DALI LGS 596x596 1 0.030 5.1 32s 159

21440 L 580 32W LED SP 596x596 1 0.038 5 22s 217

21447 L 580 32W LED BL SP 621x621 1 0.042 5.4 18s 217

21454 L 580 32W LED VS 596x596 1 0.038 6 22s 217

21461 L 580 32W LED BL VS 621x621 1 0.042 6.4 18s 217

21489 L 390 32W LED 2MG OP 597x597 1 0.038 4.5 22s 193

21491 L 390 32W LED DALI 2MG OP 597x597 1 0.038 4.7 22s 193

21497 L 390 2x18W LED 2MG OP 323x1221 1 0.042 5.1 33s 193

21499 L 390 2x18W LED DALI 2MG OP 323x1221 1 0.042 5.1 33s 193

21506 L 390 33W LED DALI HCL 2MG OP 597x597 1 0.038 7.6 22s 195

21580 L 323x10W LED LGS 596x596 1 0.030 5 32s 157

21581 L 324x10W LED LGS 596x596 1 0.030 5.2 32s 157

21586 L 323x10W LED DALI LGS 596x596 1 0.030 5 32s 157

21587 L 324x10W LED DALI LGS 596x596 1 0.030 5.2 32s 157

21589 L 323x10W LED EP LGS 596x596 1 0.030 5.9 32s 157

21590 L 324x10W LED EP LGS 596x596 1 0.030 6.1 32s 157

21598 L 323x10W LED Sensor CF LGS 596x596 1 0.030 5.2 32s 163

21600 L 322x18W LED LGS 296x1196 1 0.037 5.4 33s 157

21603 L 322x18W LED DALI LGS 296x1196 1 0.037 5.4 33s 157

21606 L 322x18W LED EP LGS 296x1196 1 0.037 5.9 33s 157

21615 L 323x10W LED DALI HCL LGS 596x596 1 0.038 8 22s 161

22281 L 561x18 HF 2M 1 0.016 2.85 86s 211

22282 L 561x36 HF 2M 1 0.031 4.9 43s 211

22283 L 561x58 HF 2M 1 0.039 6.1 43s 211

22284 L 562x18 HF 2M 1 0.016 3 86s 211

22285 L 562x36 HF 2M 1 0.031 5.1 43s 211

22286 L 562x58 HF 2M 1 0.039 6.6 43s 211

22300 L 561x18 HF 2MG 1 0.016 2.85 86s 212

22301 L 561x36 HF 2MG 1 0.031 4.9 43s 212

22302 L 561x58 HF 2MG 1 0.039 6.1 43s 212

22303 L 562x18 HF 2MG 1 0.016 3 86s 212

22304 L 562x36 HF 2MG 1 0.031 5.1 43s 212

22305 L 562x58 HF 2MG 1 0.039 6.6 43s 212

22311 L 561x18 HF 2US 1 0.016 2.85 86s 212

22312 L 561x36 HF 2US 1 0.031 4.9 43s 212

22313 L 561x58 HF 2US 1 0.039 6.1 43s 212

22314 L 562x18 HF 2US 1 0.016 3 86s 212

22315 L 562x36 HF 2US 1 0.031 5.1 43s 212

22316 L 562x58 HF 2US 1 0.039 6.6 43s 212

22330 L 561x18 HF 2S 1 0.016 2.85 86s 213

22331 L 561x36 HF 2S 1 0.031 4.9 43s 213

22332 L 561x58 HF 2S 1 0.039 6.1 43s 213

22333 L 562x18 HF 2S 1 0.016 3 86s 213

22334 L 562x36 HF 2S 1 0.031 5.1 43s 213

Code ItemPacking

Pallets PagePcs m³ Kg

22335 L 562x58 HF 2S 1 0.039 6.6 43s 213

22368 L 561x18 HF SP 1 0.016 2.95 86s 214

22369 L 561x36 HF SP 1 0.031 5.1 43s 214

22370 L 561x58 HF SP 1 0.039 6.3 43s 214

22371 L 562x18 HF SP 1 0.016 3.1 86s 214

22372 L 562x36 HF SP 1 0.031 5.3 43s 214

22373 L 562x58 HF SP 1 0.039 7 43s 214

22376 L 561x18 HF IP54 SP 1 0.016 3.2 86s 214

22377 L 561x36 HF IP54 SP 1 0.031 5.3 43s 214

22378 L 562x18 HF IP54 SP 1 0.016 3.3 86s 214

22379 L 562x36 HF IP54 SP 1 0.031 5.5 43s 214

22400 L 451x14 T5 LD HF 2MG 1 0.007 1.8 140s 205

22402 L 451x28 T5 LD HF 2MG 1 0.014 3.5 70s 205

22403 L 451x35 T5 LD HF 2MG 1 0.018 4.2 70s 205

22404 L 451x49 T5 LD HF 2MG 1 0.018 4.2 70s 205

22405 L 451x54 T5 LD HF 2MG 1 0.014 3.5 70s 205

22596 L 451x14 T5 LD HF WW 1 0.007 1.6 140s 205

22598 L 451x28 T5 LD HF WW 1 0.014 3.3 70s 205

22599 L 451x35 T5 LD HF WW 1 0.018 4 70s 205

22600 L 451x49 T5 LD HF WW 1 0.018 4 70s 205

22601 L 451x54 T5 LD HF WW 1 0.014 3.3 70s 205

27523 L 561x14 T5 LD HF 2MG 1 0.016 2.95 86s 211

27524 L 561x28 T5 LD HF 2MG 1 0.031 5 43s 211

27525 L 561x54 T5 LD HF 2MG 1 0.031 5 43s 211

27526 L 561x35 T5 LD HF 2MG 1 0.039 6.2 43s 211

27527 L 561x49 T5 LD HF 2MG 1 0.039 6.2 43s 211

27528 L 562x14 T5 LD HF 2MG 1 0.016 3.1 86s 211

27529 L 562x28 T5 LD HF 2MG 1 0.031 5.1 43s 211

27530 L 562x54 T5 LD HF 2MG 1 0.031 5.1 43s 211

27531 L 562x35 T5 LD HF 2MG 1 0.039 6.7 43s 211

27532 L 562x49 T5 LD HF 2MG 1 0.039 6.7 43s 211

27544 L 561x14 T5 LD HF 2S 1 0.016 2.95 86s 213

27545 L 561x28 T5 LD HF 2S 1 0.031 5 43s 213

27546 L 561x54 T5 LD HF 2S 1 0.031 5 43s 213

27547 L 561x35 T5 LD HF 2S 1 0.039 6.2 43s 213

27548 L 561x49 T5 LD HF 2S 1 0.039 6.2 43s 213

27549 L 562x14 T5 LD HF 2S 1 0.016 3.1 86s 213

27550 L 562x28 T5 LD HF 2S 1 0.031 5.2 43s 213

27551 L 562x54 T5 LD HF 2S 1 0.031 5.1 43s 213

27552 L 562x35 T5 LD HF 2S 1 0.039 6.7 43s 213

27553 L 562x49 T5 LD HF 2S 1 0.039 6.7 43s 213

27560 L 404x14 T5 HF 2MG 2 0.076 11.8 2s+12d 199

27561 L 403x14 T5 HF 2MG 2 0.076 11.6 2s+12d 199

27562 L 404x14 T5 HF DA 2MG 2 0.076 12.2 2s+12d 199

27563 L 403x14 T5 HF DA 2MG 2 0.076 12 2s+12d 199

27590 L 404x14 T5 HF 2S 2 0.076 11.8 2s+12d 201

27591 L 403x14 T5 HF 2S 2 0.076 11.6 2s+12d 201

27592 L 404x14 T5 HF DA 2S 2 0.076 12.2 2s+12d 201

27593 L 403x14 T5 HF DA 2S 2 0.076 12 2s+12d 201

27640 L 584x14-24 T5 HF DA RVS 1 0.037 9.95 30s 219

27643 L 582x28-54 T5 HF RVS 1 0.042 10.1 33s 219

27661 L 584x14-24 T5 HF DA BL RVS 1 0.042 10.05 26s 219

27664 L 582x28-54 T5 HF BL RVS 1 0.042 10.2 33s 219

27682 L 584x14-24 T5 HF DA CR 2US VT 1 0.053 10.5 18s 220

Page 487: 3F Filippi  "General catalogue 2016"

484

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

27724 L 584x14-24 T5 HF DA RSP 1 0.037 7.5 30s 220

27727 L 582x28-54 T5 HF RSP 1 0.042 7.65 33s 220

27745 L 584x14-24 T5 HF DA BL RSP 1 0.042 7.6 26s 220

27748 L 582x28-54 T5 HF BL RSP 1 0.042 7.75 33s 220

27902 L 594x14-24 T5 HF DA RVS 1 0.053 11.4 18s 225

27903 L 594x28-54 T5 HF DA RVS 1 0.078 19.5 14s 225

27907 L 592x28-54 T5 HF RVS 1 0.042 15.2 33s 225

27919 L 594x14-24 T5 HF DA 2US VT 1 0.053 11.4 18s 226

28826 L 323x10W LED 2S 596x596 1 0.030 4.85 32s 155

28829 L 323x10W LED EP 2S 596x596 1 0.030 5.15 32s 155

28838 L 323x10W LED DALI 2S 596x596 1 0.030 4.85 32s 155

28844 L 323x10W LED 2MG 596x596 1 0.030 4.85 32s 155

28847 L 323x10W LED EP 2MG 596x596 1 0.030 5.15 32s 155

28856 L 323x10W LED DALI 2MG 596x596 1 0.030 4.85 32s 155

34229 3F Petra OP 300 12W LED 1 0.013 1.2 96s 17

34233 3F Petra OP 300 12W LED Sensor 1 0.013 1.2 96s 19

34330 3F Petra OP 380 22W LED 1 0.022 2 54s 17

34334 3F Petra OP 380 22W LED Sensor 1 0.022 2 54s 19

34345 3F Petra OP 620 1x40+1x60 T5-R LDHFDA SO 1 0.055 5.8 18s 25

34407 3F Petra OP 620 50W LED 1 0.055 6 18s 17

34650 3F Petra Trasparente 620 4x26CD LD HF DA 1 0.055 5.7 18s 22

34653 3F Petra Tras.620 1x40+60 T5-R LD HF DA 1 0.055 5.8 18s 22

34658 3F Petra Trasp 620 4x26 CD LD HF DA EP 1 0.055 6.2 18s 22

35050 3F Petra GR 300 1x22 LD 1 0.013 1.35 96s 23

35100 3F Petra GR 300 1x22 T5-R LD HF 1 0.013 1.25 96s 23

35103 3F Petra GR 300 1x13 CD LD HF 1 0.013 1.15 96s 23

35104 3F Petra GR 300 1x18 CD LD HF 1 0.013 1.1 96s 23

35105 3F Petra GR 300 1x26 CD LD HF 1 0.013 1.2 96s 23

35108 3F Petra GR 300 2x13 CD LD HF 1 0.013 1.6 96s 23

35125 3F Petra GR 300 1x22 T5-R LD HF EP 1 0.013 1.75 96s 23

35130 3F Petra GR 300 1x26 CD LD HF EP 1 0.013 1.7 96s 23

35205 3F Petra GR 380 1x32 LD HF 1 0.022 2.5 54s 23

35207 3F Petra GR 380 1x32 LD HF EP 1 0.022 3 54s 23

35211 3F Petra GR 380 1x40 T5-R LD HF 1 0.022 2 54s 23

35219 3F Petra GR 380 2x18 CD LD HF 1 0.022 2.25 54s 23

35220 3F Petra GR 380 2x26 CD LD HF 1 0.022 2.35 54s 23

35231 3F Petra GR 380 1x40 T5-R LD HF EP 1 0.022 2.5 54s 23

35240 3F Petra GR 380 2x26 CD LD HF EP 1 0.022 2.85 54s 23

35465 3F Petra ME OP 300 1x22 T5-R LD HF IP64 1 0.013 1.25 96s 21

35705 3F Petra Trasparente 300 1x26 CD LD HF 1 0.013 1.2 96s 22

35730 3F Petra Trasparente 300 1x26 CD LD HF EP 1 0.013 1.7 96s 22

35811 3F Petra Trasparente 380 1x40 T5-R LD HF 1 0.022 2 54s 22

35820 3F Petra Trasparente 380 2x26 CD LD HF 1 0.022 2.35 54s 22

35831 3F Petra Trasp 380 1x40 T5-R LD HF EP 1 0.022 2.5 54s 22

35840 3F Petra Trasparente 380 2x26 CD LD HF EP 1 0.022 2.85 54s 22

36202 3F Dodeca 220 AC 1x26 CD HF 2MG VDT 1 0.019 1.9 90s 145

36205 3F Dodeca 220 AC 2x26 CD HF 2MG VDT 1 0.019 2.75 90s 145

36231 3F Dodeca 220 AC 1x26 CD HF EP 2MG VDT 1 0.019 2.7 60s 145

36234 3F Dodeca 220 AC 2x26 CD HF EP 2MG VDT 1 0.019 3.55 60s 145

36381 3F Dodeca 300 2x32 CT HF 2MG SK 1 0.022 2.8 60s 151

36382 3F Dodeca 300 2x42 CT HF 2MG SK 1 0.022 2.85 60s 151

36423 3F Dodeca 300 2x32 CT HF EP 2MG SK 1 0.026 3.75 45s 151

36424 3F Dodeca 300 2x42 CT HF EP 2MG SK 1 0.026 3.8 45s 151

36575 Lucequadro LED 2000 VS 1 0.007 3.5 130s 127

Code ItemPacking

Pallets PagePcs m³ Kg

36576 Lucequadro LED 2000 EP VS 1 0.019 4.3 76s 127

36578 Lucequadro LED 3000 VS 1 0.007 3.5 130s 127

36579 Lucequadro LED 3000 EP VS 1 0.019 4.3 76s 127

36581 Lucequadro LED 2000 VOP 1 0.007 3.5 130s 127

36582 Lucequadro LED 2000 EP VOP 1 0.019 4.3 76s 127

36584 Lucequadro LED 3000 VOP 1 0.007 3.5 130s 127

36585 Lucequadro LED 3000 EP VOP 1 0.019 4.3 76s 127

36587 Lucequadro LED 2000 SOP 1 0.008 3.2 130s 128

36588 Lucequadro LED 2000 EP SOP 1 0.019 4 76s 128

36590 Lucequadro LED 3000 SOP 1 0.008 3.2 130s 128

36591 Lucequadro LED 3000 EP SOP 1 0.019 4 76s 128

36601 Lucequadro LED 4000 2MG VDT 1 0.018 3 54s 131

37507 3F Drop LED GR 3000 2 0.011 6 36d 27

37542 Galassia 220 LED AB 2000 VOP 1 0.007 2.5 130s 138

37544 Galassia 220 LED AB 2000 EP VOP 1 0.019 3.5 45s 138

37551 Galassia 220 LED AB 2000 VS 1 0.007 2.5 130s 137

37553 Galassia 220 LED AB 2000 EP VS 1 0.019 3.5 45s 137

37578 Galassia 220 LED AB 3000 VOP 1 0.007 2.5 130s 138

37580 Galassia 220 LED AB 3000 EP VOP 1 0.019 3.5 45s 138

37587 Galassia 220 LED AB 3000 VS 1 0.007 2.5 130s 137

37589 Galassia 220 LED AB 3000 EP VS 1 0.019 3.5 45s 137

37604 Galassia 220 LED AB 4000 VS 1 0.011 3 80s 137

37608 Galassia 220 LED AB 4000 VOP 1 0.011 3 80s 138

37750 Galassia 220 LED 2000 1 0.007 2 130s 135

37752 Galassia 220 LED 2000 EP 1 0.019 3 45s 135

37759 Galassia 220 LED 2000 VT 1 0.007 2.5 130s 135

37761 Galassia 220 LED 2000 EP VT 1 0.019 3.5 45s 135

37768 Galassia 220 LED 2000 VOP 1 0.007 2.5 130s 136

37770 Galassia 220 LED 2000 EP VOP 1 0.019 3.5 45s 136

37777 Galassia 220 LED 2000 VS 1 0.007 2.5 130s 136

37779 Galassia 220 LED 2000 EP VS 1 0.019 3.5 45s 136

37793 Galassia 220 LED 3000 1 0.007 2 130s 135

37795 Galassia 220 LED 3000 EP 1 0.019 3 45s 135

37802 Galassia 220 LED 3000 VT 1 0.007 2.5 130s 135

37804 Galassia 220 LED 3000 EP VT 1 0.019 3.5 45s 135

37811 Galassia 220 LED 3000 VOP 1 0.007 2.5 130s 136

37813 Galassia 220 LED 3000 EP VOP 1 0.019 3.5 45s 136

37820 Galassia 220 LED 3000 VS 1 0.007 2.5 130s 136

37822 Galassia 220 LED 3000 EP VS 1 0.019 3.5 45s 136

37830 Galassia 220 LED 4000 1 0.011 2.5 80s 135

37834 Galassia 220 LED 4000 VT 1 0.011 3 80s 135

37838 Galassia 220 LED 4000 VS 1 0.011 3 80s 136

37842 Galassia 220 LED 4000 VOP 1 0.011 3 80s 136

37859 3F Petra OP 300 1x22 T5-R LD HF IP64 1 0.013 1.25 96s 21

37864 3F Petra OP 300 1x26 CD LD HF IP64 1 0.013 1.2 96s 21

37884 3F Petra OP 300 1x22 T5-R LD HF EP IP64 1 0.013 1.75 96s 21

37889 3F Petra OP 300 1x26 CD LD HF EP IP64 1 0.013 1.7 96s 21

37927 3F Petra ME OP 380 1x22 T5-R LD HF IP64 1 0.022 1.95 54s 21

37928 3F Petra ME OP 380 1x40 T5-R LD HF IP64 1 0.022 2 54s 21

37941 3F Petra OP 620 1x40+1x60T5-RLDHFDA IP65 1 0.055 5.8 18s 21

37969 3F Petra OP 380 1x22 T5-R LD HF IP64 1 0.022 1.95 54s 21

37970 3F Petra OP 380 1x40 T5-R LD HF IP64 1 0.022 2 54s 21

37979 3F Petra OP 380 2x26 CD LD HF IP64 1 0.022 2.35 54s 21

37989 3F Petra OP 380 1x22 T5-R LD HF EP IP64 1 0.022 2.45 54s 21

Page 488: 3F Filippi  "General catalogue 2016"

485

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

37990 3F Petra OP 380 1x40 T5-R LD HF EP IP64 1 0.022 2.5 54s 21

37999 3F Petra OP 380 2x26 CD LD HF EP IP64 1 0.022 2.85 54s 21

40911 3F Rocket M LED B 3000/930 1 0.033 2 36s 271

40912 3F Rocket M LED GR 3000/930 1 0.033 2 36s 271

40916 3F Rocket M LED B 2000/MEAT 1 0.033 2 36s 271

40917 3F Rocket M LED GR 2000/MEAT 1 0.033 2 36s 271

40921 3F Rocket M LED B 2000/FRESH FOOD 1 0.033 2 36s 271

40922 3F Rocket M LED GR 2000/FRESH FOOD 1 0.033 2 36s 271

40979 3F Rocket L LED GR 4000/930 1 0.010 2.1 36s 273

40980 3F Rocket L LED B 4000/930 1 0.010 2.1 36s 273

40984 3F Rocket L LED GR 5000/930 1 0.010 2.1 36s 273

40985 3F Rocket L LED B 5000/930 1 0.010 2.1 36s 273

48017 3F Fil 180 LED 2x30W RSP L1550 1 0.026 6.7 60s 277

48019 3F Fil 180 LED 2+2x30W RSP L3100 1 0.051 13.5 60s 277

48026 3F Fil 180 LED 2x22W RSP L1550 1 0.026 6.7 60s 277

48028 3F Fil 180 LED 2+2x22W RSP L3100 1 0.051 13.5 60s 277

48030 3F Fil 180 LED 2x30W RSP AMPIO L1550 1 0.026 6.7 60s 277

48032 3F Fil 180 LED 2+2x30W RSP AMPIO L3100 1 0.051 13.5 60s 277

48060 3F Fil 180 LED 1x30W 2US L1550 1 0.026 6.2 60s 278

48062 3F Fil 180 LED 2x30W 2US L1550 1 0.026 6.4 60s 278

48064 3F Fil 180 LED 1+1x30W 2US L3100 1 0.051 12.4 60s 278

48066 3F Fil 180 LED 2+2x30W 2US L3100 1 0.051 12.8 60s 278

53438 i3F LED 764x50W CR AMPIO VT L1251 1 0.095 18.9 15s 371

53445 i3F LED 764x63W CR AMPIO VT L1551 1 0.117 20.9 15s 371

53452 i3F LED 764x50W CR AMPIO SL L1251 1 0.095 15.5 15s 371

53459 i3F LED 764x63W CR AMPIO SL L1551 1 0.117 17.5 15s 371

53490 Beta Iperconc LED 4x30W CR VT IP64 L1551 1 0.117 20 15s 371

53493 Beta Iperconc LED 4x30W CR SL IP64 L1551 1 0.117 17 15s 371

53860 A3F Ice LED 902x12W UR95 AMPIO L655 1 0.017 3.8 80s 347

53861 A3F Ice LED 902x24W UR95 AMPIO L1265 1 0.042 6 42s 347

53862 A3F Ice LED 902x30W UR95 AMPIO L1565 1 0.052 7 42s 347

53863 A3F Ice LED 902x60W UR95 AMPIO L1565 1 0.039 7.8 42s 347

53867 A3F Ice LED 902x30W UR95 CONC L1565 1 0.052 7 42s 347

53868 A3F Ice LED 902x60W UR95 CONC L1565 1 0.052 7.8 42s 347

53884 A3F 931x18 HF 1 0.017 4.6 80s 368

53885 A3F 932x18 HF 1 0.017 4.8 80s 368

53890 A3F 931x36 HF AMPIO 1 0.031 8 42s 368

53891 A3F 931x58 HF AMPIO 1 0.039 9.3 42s 368

53892 A3F 932x36 HF AMPIO 1 0.031 8.1 42s 368

53893 A3F 932x58 HF AMPIO 1 0.039 9.8 42s 368

53898 A3F 932x36 HF EP AMPIO 1 0.031 8.6 42s 368

53899 A3F 932x58 HF EP AMPIO 1 0.039 10.6 42s 368

53904 A3F 931x58 HF CONC 1 0.039 9.3 42s 368

53905 A3F 932x58 HF CONC 1 0.039 9.8 42s 368

53934 3F Linda HS 1x49 T5 LD HF 1 0.020 2.97 90s 327

53956 3F Linda HS 2x49 T5 LD HF 1 0.030 4.08 56s 327

55006 i3F LED 752x30W CONC L1565 1 0.052 7.5 31s 339

55017 i3F LED 752x30W EP CONC L1565 1 0.052 8.5 31s 339

55072 i3F LED 762x30W AMPIO VT L1565 1 0.039 10.5 42s 340

55083 i3F LED 762x30W EP AMPIO VT L1565 1 0.039 11.5 42s 340

55134 i3F LED 762x12W AMPIO VS L655 1 0.017 5.1 80s 340

55136 i3F LED 762x24W AMPIO VS L1265 1 0.031 8.45 42s 340

55138 i3F LED 762x30W AMPIO VS L1565 1 0.039 10.5 42s 340

55145 i3F LED 762x12W EP AMPIO VS L655 1 0.017 6.1 80s 340

Code ItemPacking

Pallets PagePcs m³ Kg

55147 i3F LED 762x24W EP AMPIO VS L1265 1 0.031 9.45 42s 340

55149 i3F LED 762x30W EP AMPIO VS L1565 1 0.039 11.5 42s 340

55205 A3F LED 902x44W AMPIO L1565 1 0.052 7.3 31s 343

55271 A3F LED 912x44W AMPIO VT L1565 1 0.039 10.5 42s 344

55337 A3F LED 912x44W AMPIO VS L1565 1 0.039 10.5 42s 344

55596 i3F LED 752x12W AMPIO L655 1 0.017 3.7 80s 339

55598 i3F LED 752x24W AMPIO L1265 1 0.042 6.2 31s 339

55600 i3F LED 752x30W AMPIO L1565 1 0.052 7.5 31s 339

55607 i3F LED 752x12W EP AMPIO L655 1 0.017 4.7 80s 339

55609 i3F LED 752x24W EP AMPIO L1265 1 0.042 7.2 31s 339

55611 i3F LED 752x30W EP AMPIO L1565 1 0.052 8.5 31s 339

55666 i3F LED 762x30W CONC VT L1565 1 0.039 10.5 42s 341

55677 i3F LED 762x30W EP CONC VT L1565 1 0.039 11.5 42s 341

55799 A3F LED 902x44W CONC L1565 1 0.052 7.3 31s 343

55865 A3F LED 912x44W CONC VT L1565 1 0.039 10.5 42s 345

55931 3F LEM 2 LED 100 AMPIO 1 0.045 12 28s 291

55932 3F LEM 3 LED 150 AMPIO 1 0.052 15 28s 291

55933 3F LEM 4 LED 200 AMPIO 1 0.068 18 12s 291

55938 3F LEM 3 LED 150 CONC 1 0.052 15 28s 291

55939 3F LEM 4 LED 200 CONC 1 0.068 18 12s 291

55943 3F LEM 2 LED 100 DALI AMPIO 1 0.045 12 28s 293

55944 3F LEM 3 LED 150 DALI AMPIO 1 0.052 15 28s 293

55945 3F LEM 4 LED 200 DALI AMPIO 1 0.068 18 12s 293

55950 3F LEM 3 LED 150 DALI CONC 1 0.052 15 28s 293

55951 3F LEM 4 LED 200 DALI CONC 1 0.068 18 12s 293

56003 3F LEM 2 LED 100/865 AMPIO 1 0.045 12 28s 292

56004 3F LEM 3 LED 150/865 AMPIO 1 0.052 15 28s 292

56005 3F LEM 4 LED 200/865 AMPIO 1 0.068 18 12s 292

56010 3F LEM 3 LED 150/865 CONC 1 0.052 15 28s 292

56011 3F LEM 4 LED 200/865 CONC 1 0.068 18 12s 292

56076 3F LEM 3 LED 150 DALI Sensor AMPIO 1 0.068 15.4 28s 299

56077 3F LEM 4 LED 200 DALI Sensor AMPIO 1 0.078 18.4 12s 299

56082 3F LEM 3 LED 150 DALI Sensor CONC 1 0.068 15.4 28s 299

56083 3F LEM 4 LED 200 DALI Sensor CONC 1 0.078 18.4 12s 299

56123 3F LEM 2 HT LED 60 AMPIO 1 0.045 12 28s 301

56124 3F LEM 3 HT LED 90 AMPIO 1 0.052 14.5 28s 301

56125 3F LEM 4 HT LED 120 AMPIO 1 0.068 17.5 12s 301

56130 3F LEM 3 HT LED 90 CONC 1 0.052 15 28s 301

56131 3F LEM 4 HT LED 120 CONC 1 0.068 18 12s 301

56200 3F Cub R90 4x55 CR 2 0.191 17 2s+5d 387

56203 3F Cub R90 4x55 EP CR 2 0.191 18.6 2s+5d 387

56206 3F Cub R90 4x55 CR CONC 2 0.191 17 2s+5d 388

56208 3F Cub R90 4x55 EP CR CONC 2 0.191 20.6 2s+5d 388

56210 3F Cub 4x55 CR VT IP64 2 0.191 25 2s+5d 387

56211 3F Cub 4x55 EP CR VT IP64 2 0.191 27.6 2s+5d 387

56212 3F Cub 4x55 CR CONC VT IP64 2 0.191 25 2s+5d 388

56213 3F Cub 4x55 EP CR CONC VT IP64 2 0.191 27.6 2s+5d 388

56214 3F Cub 4x55 CR SL IP64 2 0.191 18 2s+5d 387

56215 3F Cub 4x55 EP CR SL IP64 2 0.191 22.4 2s+5d 387

56216 3F Cub 4x55 CR CONC SL IP64 2 0.191 22.8 2s+5d 388

56217 3F Cub 4x55 EP CR CONC SL IP64 2 0.191 24.4 2s+5d 388

56330 3F CUB LED 100W CR VT 2 0.191 23.6 2s+5d 381

56332 3F CUB LED 100W DALI CR VT 2 0.191 23.6 2s+5d 381

56333 3F CUB LED 150W CR VT 2 0.191 24 2s+5d 381

Page 489: 3F Filippi  "General catalogue 2016"

486

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

56335 3F CUB LED 150W DALI CR VT 2 0.191 24 2s+5d 381

56337 3F CUB LED 100W CR VS 2 0.191 23.6 2s+5d 382

56339 3F CUB LED 100W DALI CR VS 2 0.191 23.6 2s+5d 382

56340 3F CUB LED 150W CR VS 2 0.191 24 2s+5d 382

56342 3F CUB LED 150W DALI CR VS 2 0.191 24 2s+5d 382

56344 3F CUB LED 100W CR SP 2 0.191 19.6 2s+5d 381

56346 3F CUB LED 100W DALI CR SP 2 0.191 19.6 2s+5d 381

56347 3F CUB LED 150W CR SP 2 0.191 20 2s+5d 381

56349 3F CUB LED 150W DALI CR SP 2 0.191 20 2s+5d 381

56400 i3F 751x49 T5 HO HF AMPIO 1 0.052 7.35 31s 356

56401 i3F 751x80 T5 HO HF AMPIO 1 0.052 7.35 31s 356

56402 i3F 752x49 T5 HO HF AMPIO 1 0.052 8 31s 356

56403 i3F 752x80 T5 HO HF AMPIO 1 0.052 8 31s 356

56406 i3F 751x80 T5 HO HF CONC 1 0.052 7.35 31s 356

56407 i3F 752x80 T5 HO HF CONC 1 0.052 8 31s 356

56410 i3F 761x49 T5 HO HF AMPIO 1 0.039 10.15 42s 358

56411 i3F 761x80 T5 HO HF AMPIO 1 0.039 10.15 42s 358

56412 i3F 762x49 T5 HO HF AMPIO 1 0.039 10.7 42s 358

56413 i3F 762x80 T5 HO HF AMPIO 1 0.039 10.7 42s 358

56416 i3F 761x80 T5 HO HF CONC 1 0.039 10.15 42s 358

56417 i3F 762x80 T5 HO HF CONC 1 0.039 10.7 42s 358

56420 A3F 901x49 T5 HO HF AMPIO 1 0.039 6.15 42s 362

56421 A3F 901x80 T5 HO HF AMPIO 1 0.039 6.15 42s 362

56422 A3F 902x49 T5 HO HF AMPIO 1 0.039 6.7 42s 362

56423 A3F 902x80 T5 HO HF AMPIO 1 0.039 6.7 42s 362

56426 A3F 901x80 T5 HO HF CONC 1 0.039 6.15 42s 362

56427 A3F 902x80 T5 HO HF CONC 1 0.039 6.7 42s 362

56430 A3F 911x49 T5 HO HF AMPIO 1 0.039 9.15 42s 364

56431 A3F 911x80 T5 HO HF AMPIO 1 0.039 9.15 42s 364

56432 A3F 912x49 T5 HO HF AMPIO 1 0.039 9.7 42s 364

56433 A3F 912x80 T5 HO HF AMPIO 1 0.039 9.7 42s 364

56436 A3F 911x80 T5 HO HF CONC 1 0.039 9.15 42s 364

56437 A3F 912x80 T5 HO HF CONC 1 0.039 9.7 42s 364

56450 i3F 764x54 T5 HO LD HF CR AMPIO IP64 1 0.095 17.9 15s 374

56451 i3F 764x80 T5 HO LD HF CR AMPIO IP64 1 0.117 19.5 15s 374

56453 i3F 764x80 T5 HO LD HF CR CONC IP64 1 0.117 19.5 15s 375

56458 i3F 714x54 T5 HO LD HF CR AMPIO IP43 1 0.095 10.5 12s 373

56459 i3F 714x80 T5 HO LD HF CR AMPIO IP43 1 0.117 13.9 12s 373

56461 i3F 714x80 T5 HO LD HF CR CONC IP43 1 0.117 13.9 12s 373

56466 i3F 764x54 T5 HO LD HF CR AMPIO SL IP64 1 0.095 17.9 15s 374

56467 i3F 764x80 T5 HO LD HF CR AMPIO SL IP64 1 0.117 19.5 15s 374

56469 i3F 764x80 T5 HO LD HF CR CONC SL IP64 1 0.117 19.5 15s 375

56474 i3F 766x49 T5 HO LD HF CR AMPIO IP64 1 0.117 20 15s 374

56475 i3F 766x54 T5 HO LD HF CR AMPIO IP64 1 0.095 18.5 15s 374

56478 i3F 766x49 T5 HO LD HF CR CONC IP64 1 0.117 20 15s 375

56479 i3F 766x54 T5 HO LD HF CR CONC IP64 1 0.095 18.5 15s 375

56484 i3F 716x49 T5 HO LD HF CR AMPIO IP43 1 0.117 13 42s 373

56485 i3F 716x54 T5 HO LD HF CR AMPIO IP43 1 0.095 12.6 12s 373

56488 i3F 716x49 T5 HO LD HF CR CONC IP43 1 0.117 13 42s 373

56489 i3F 716x54 T5 HO LD HF CR CONC IP43 1 0.095 12.6 12s 373

56494 i3F 766x49 T5 HO LD HF CR AMPIO SL IP64 1 0.117 20 15s 374

56495 i3F 766x54 T5 HO LD HF CR AMPIO SL IP64 1 0.095 18.5 15s 374

56498 i3F 766x49 T5 HO LD HF CR CONC SL IP64 1 0.117 20 15s 375

56499 i3F 766x54 T5 HO LD HF CR CONC SL IP64 1 0.095 18.5 15s 375

Code ItemPacking

Pallets PagePcs m³ Kg

56510 Beta Iperconc 2x80 T5 HO LD HF CR VT IP64 1 0.117 19 15s 375

56511 Beta Iperc. 2+2x80T5 HO LD HF CR VT IP64 1 0.117 20.5 15s 375

56512 Beta Iperc. 2+2x54T5 HO LD HF CR VT IP64 1 0.095 17.5 15s 375

56515 Beta Iperconc 2x80 T5 HO LD HF CR IP43 1 0.117 13 12s 374

56516 Beta Iperconc 2+2x80 T5 HO LD HF CR IP43 1 0.117 14 12s 374

56517 Beta Iperconc 2+2x54 T5 HO LD HF CR IP43 1 0.095 11 12s 374

56520 Beta Iperconc 2x80 T5 HO LD HF CR SL IP64 1 0.117 16 15s 375

56521 Beta Iperc. 2+2x80T5 HO LD HF CR SL IP64 1 0.117 17.5 15s 375

56522 Beta Iperc. 2+2x54T5 HO LD HF CR SL IP64 1 0.095 15 15s 375

56583 3F LEM 2 HO LED 140 AMPIO 1 0.045 12 28s 295

56584 3F LEM 3 HO LED 210 AMPIO 1 0.052 15 21s 295

56585 3F LEM 4 HO LED 280 AMPIO 1 0.068 18 12s 295

56589 3F LEM 2 HO LED 140 CONC 1 0.045 12 28s 295

56590 3F LEM 3 HO LED 210 CONC 1 0.052 15 21s 295

56595 3F LEM 2 HO LED 140 DALI AMPIO 1 0.045 12 28s 296

56596 3F LEM 3 HO LED 210 DALI AMPIO 1 0.052 15 21s 296

56597 3F LEM 4 HO LED 280 DALI AMPIO 1 0.068 18 12s 296

56601 3F LEM 2 HO LED 140 DALI CONC 1 0.045 12 28s 296

56602 3F LEM 3 HO LED 210 DALI CONC 1 0.052 15 21s 296

57004 i3F 714x58 LD HF CR AMPIO IP43 1 0.117 13 12s 373

57012 i3F 714x58 LD HF CR CONC IP43 1 0.117 13 12s 373

57049 i3F 764x58 LD HF CR AMPIO SL IP64 1 0.117 16.1 15s 374

57055 i3F 764x58 LD HF CR CONC SL IP64 1 0.117 16.1 15s 375

57094 i3F 764x58 LD HF CR AMPIO IP64 1 0.117 19.7 15s 374

57102 i3F 764x58 LD HF CR CONC IP64 1 0.117 19.7 15s 375

57390 i3F 764x55 C AMPIO IP64 1 0.050 11.56 28s 374

58457 3F Linda LED Ice 1x24W UR95 L1270 1 0.016 2.5 90s 319

58459 3F Linda LED Ice 2x24W UR95 L1270 1 0.024 3.3 56s 319

58461 3F Linda LED Ice 1x30W UR95 L1570 1 0.020 3 90s 319

58463 3F Linda LED Ice 2x30W UR95 L1570 1 0.030 3.7 56s 319

58561 3F Linda LED 1x12W L660 1 0.008 1.42 180s 307

58563 3F Linda LED 1x6W L660 1 0.008 1.42 180s 307

58567 3F Linda LED 1x12W EP LA L660 1 0.013 1.95 112s 307

58569 3F Linda LED 1x6W EP LA L660 1 0.013 1.95 112s 307

58583 3F Linda LED 1x24W L1270 1 0.016 2.32 90s 307

58589 3F Linda LED 1x24W EP L1270 1 0.016 3.1 90s 307

58594 3F Linda LED 2x24W L1270 1 0.024 3.1 56s 307

58595 3F Linda LED 2x24W/865 L1270 1 0.024 3.1 56s 307

58596 3F Linda LED 2x24W/830 L1270 1 0.024 3.1 56s 307

58600 3F Linda LED 2x24W EP L1270 1 0.024 3.3 56s 307

58601 3F Linda LED 2x24W/865 EP L1270 1 0.024 3.3 56s 307

58602 3F Linda LED 2x24W/830 EP L1270 1 0.024 3.3 56s 307

58605 3F Linda LED 1x30W L1570 1 0.020 2.8 90s 307

58611 3F Linda LED 1x30W EP L1570 1 0.020 3.8 90s 307

58616 3F Linda LED 2x30W L1570 1 0.030 4 56s 307

58617 3F Linda LED 2x30W/865 L1570 1 0.030 3.7 56s 307

58618 3F Linda LED 2x30W/830 L1570 1 0.030 3.7 56s 307

58623 3F Linda LED 2x30W EP L1570 1 0.030 4.5 56s 307

58624 3F Linda LED 2x30W/865 EP L1570 1 0.030 3.9 56s 307

58625 3F Linda LED 2x30W/830 EP L1570 1 0.030 3.9 56s 307

58630 3F Linda LED 2x24W CONC L1270 1 0.024 3.6 56s 309

58632 3F Linda LED 2x30W CONC L1570 1 0.030 4.3 56s 309

58638 3F Linda LED 1x30W Sensor L1570 1 0.020 3 90s 321

58642 3F Linda LED 2x30W Sensor L1570 1 0.030 4 56s 321

Page 490: 3F Filippi  "General catalogue 2016"

487

Analytical guideCode Item

PackingPallets Page

Pcs m³ Kg

58645 3F Linda LED 1x30W Sensor CF L1570 1 0.020 3 90s 321

58649 3F Linda LED 2x30W Sensor CF L1570 1 0.030 4 56s 321

58659 3F Linda LED 2x24W AMPIO L1270 1 0.024 3.6 56s 309

58661 3F Linda LED 2x30W AMPIO L1570 1 0.030 4.3 56s 309

58705 3F Linda LED 1x12W ENP LA L660 1 0.013 1.75 112s 307

58713 3F Linda LED 1x24W ENP L1270 1 0.016 2.55 90s 307

58724 3F Linda LED HS 1x30W L1570 1 0.020 2.8 90s 310

58730 3F Linda LED HS 2x30W L1570 1 0.030 3.7 56s 310

58742 3F Linda LED OP 1x12W L660 1 0.008 1.42 180s 315

58745 3F Linda LED OP 1x24W L1270 1 0.016 2.32 90s 315

58748 3F Linda LED OP 1x30W L1570 1 0.020 2.8 90s 315

58762 3F Linda LED Basic 1x19W L1270 1 0.016 2.32 90s 310

58763 3F Linda LED Basic 2x19W L1270 1 0.024 3.1 56s 310

58764 3F Linda LED Basic 1x23W L1570 1 0.020 2.8 90s 310

58765 3F Linda LED Basic 2x23W L1570 1 0.030 3.7 56s 310

58806 3F Linda LED Trasparente 1x12W L660 1 0.008 1.42 180s 317

58808 3F Linda LED Trasparente 1x24W L1270 1 0.016 2.32 90s 317

58809 3F Linda LED Trasparente 2x24W L1270 1 0.024 3.1 56s 317

58810 3F Linda LED Trasparente 1x30W L1570 1 0.020 2.8 90s 317

58811 3F Linda LED Trasparente 2x30W L1570 1 0.030 3.7 56s 317

164719 3F Canda LED 2x8W 2MG 300x300 1 0.009 1.8 144s 35

164723 3F Canda LED 2x8W SP 300x300 1 0.009 1.9 144s 35

164732 3F Canda LED 2x12W 2MG 430x430 1 0.018 3 70s 35

164736 3F Canda LED 2x12W SP 430x430 1 0.018 3.2 70s 35

166027 3F Canda 2x28 T5 HF 2MG 1 0.028 6.15 44s 37

166029 3F Canda 2x35 T5 HF 2MG 1 0.034 7.25 44s 37

166041 3F Canda 2x28 T5 HF EP 2MG 1 0.028 6.95 44s 37

166043 3F Canda 2x35 T5 HF EP 2MG 1 0.034 8.05 44s 37

166055 3F Canda 2x28 T5 HF D1-10V 2MG 1 0.028 6.35 44s 37

166057 3F Canda 2x35 T5 HF D1-10V 2MG 1 0.034 7.5 44s 37

167327 3F Canda DI 2x28 T5 HF 2MG 1 0.028 5.75 44s 38

167329 3F Canda DI 2x35 T5 HF 2MG 1 0.034 6.8 44s 38

167341 3F Canda DI 2x28 T5 HF EP 2MG 1 0.028 6.55 44s 38

167343 3F Canda DI 2x35 T5 HF EP 2MG 1 0.034 7.6 44s 38

167355 3F Canda DI 2x28 T5 HF D1-10V 2MG 1 0.028 5.85 44s 38

167357 3F Canda DI 2x35 T5 HF D1-10V 2MG 1 0.034 6.9 44s 38

170215 Barraluce P 1x28-54 T5 HF OP 1 0.050 4 70s 119

170221 Barraluce P 1x35-49-80 T5 HF OP 1 0.050 4.5 70s 119

171536 Barraluce P 1x28-54 T5 HF 2MG 1 0.050 4 70s 121

171543 Barraluce P 1x35-49-80 T5 HF 2MG 1 0.050 4.5 70s 121

172005 Barraluce P 1x28-54 T5 HF OP IFC 5P 1 0.050 4 70s 119

172012 Barraluce P 1x35-49-80 T5 HF OP IFC 5P 1 0.050 4.5 70s 119

172019 Barraluce P 1+1x28-54 T5 HF OP IFC 5P 1 0.050 8 70s 119

172026 Barraluce P 1+1x35-49-80 T5 HF OP IFC 5P 1 0.050 9 70s 119

172507 Barraluce P 1+1x28-54 T5 HF OP IC 5P 1 0.050 8 70s 119

172514 Barraluce P 1+1x35-49-80 T5 HF OP IC 5P 1 0.050 9 70s 119

173423 Barraluce P 1x28-54 T5 HF 2MG IFC 5P 1 0.050 4 70s 121

173430 Barraluce P 1x35-49-80 T5 HF 2MG IFC 5P 1 0.050 4.5 70s 121

173437 Barraluce P 1+1x28-54 T5 HF 2MG IFC 5P 1 0.050 8 70s 121

173444 Barraluce P 1+1x35-49-80 T5 HF 2MG IFC 5P 1 0.050 9 70s 121

173589 Barraluce P 1+1x28-54 T5 HF 2MG IC 5P 1 0.050 8 70s 121

173590 Barraluce P 1+1x35-49-80 T5 HF 2MG IC 5P 1 0.050 9 70s 121

260078 L 353x25W LED 3AO 596x596 1 0.030 4.5 32s 185

260080 L 353x25W LED DALI 3AO 596x596 1 0.030 4.5 32s 185

Code ItemPacking

Pallets PagePcs m³ Kg

260092 L 353x14W LED SP 54V 596x596 1 0.030 5 32s 185

260094 L 353x14W LED DALI SP 54V 596x596 1 0.030 5 32s 185

260171 Barraluce L 1x28-54 T5 HF OP 1 0.050 4 70s 233

260182 Barraluce L 1x35-49-80 T5 HF OP 1 0.050 4.5 70s 233

260565 Barraluce L 2x28-54 T5 HF OP 1 0.050 4.5 70s 233

260572 Barraluce L 2x35-49-80 T5 HF OP 1 0.050 5 70s 233

263060 Barraluce L 1x28-54 T5 HF 2MG 1 0.050 4 70s 235

263071 Barraluce L 1x35-49-80 T5 HF 2MG 1 0.050 4.5 70s 235

263455 Barraluce L 2x28-54 T5 HF 2MG 1 0.050 4.5 70s 235

263462 Barraluce L 2x35-49-80 T5 HF 2MG 1 0.050 5 70s 235

265007 Barraluce L 1x28-54 T5 HF OP IFC 5P 1 0.050 4 70s 233

265014 Barraluce L 1x35-49-80 T5 HF OP IFC 5P 1 0.050 4.5 70s 233

265021 Barraluce L 1+1x28-54 T5 HF OP IFC 5P 1 0.050 8 70s 233

265028 Barraluce L 1+1x35-49-80 T5 HF OP IFC 5P 1 0.050 9 70s 233

265879 Barraluce L 1+1x28-54 T5 HF OP IC 5P 1 0.050 8 70s 233

265886 Barraluce L 1+1x35-49-80 T5 HF OP IC 5P 1 0.050 9 70s 233

268004 Barraluce L 1x28-54 T5 HF 2MG 5P 1 0.050 4 70s 235

268011 Barraluce L 1x35-49-80 T5 HF 2MG 5P 1 0.050 4.5 70s 235

268018 Barraluce L 1+1x28-54 T5 HF 2MG 5P 1 0.050 8 70s 235

268025 Barraluce L 1+1x35-49-80 T5 HF 2MG 5P 1 0.050 9 70s 235

269330 Barraluce L 1x30W LED SP L1496 1 0.050 4.6 70s 230

269332 Barraluce L 1+1x30W LED SP L2962 1 0.050 9.2 70s 230

269338 Barraluce L 1x30W LED SP 5P L1466 1 0.050 4.9 70s 230

269340 Barraluce L 1+1x30W LED SP 5P L2932 1 0.050 9.8 70s 230

269346 Barraluce L 1x30W LED OP L1496 1 0.050 4.6 70s 229

269348 Barraluce L 1+1x30W LED OP L2962 1 0.050 9.2 70s 229

269354 Barraluce L 1x30W LED OP 5P L1466 1 0.050 4.9 70s 229

269356 Barraluce L 1+1x30W LED OP 5P L2932 1 0.050 9.8 70s 229

270931 L 561x12W LED 2S 221x647 1 0.016 3 86s 209

270933 L 561x24W LED 2S 221x1256 1 0.031 5 43s 209

270935 L 561x30W LED 2S 221x1556 1 0.039 6.2 43s 209

270937 L 562x12W LED 2S 221x647 1 0.016 3.2 86s 209

270939 L 562x24W LED 2S 221x1256 1 0.031 5.2 43s 209

270941 L 562x30W LED 2S 221x1556 1 0.039 6.4 43s 209

270957 L 561x12W LED SP 221x647 1 0.016 3.2 86s 209

270959 L 561x24W LED SP 221x1256 1 0.031 5.2 43s 209

270961 L 561x30W LED SP 221x1556 1 0.039 6.4 43s 209

270963 L 562x12W LED SP 221x647 1 0.016 3.4 86s 209

270965 L 562x24W LED SP 221x1256 1 0.031 5.4 43s 209

270967 L 562x30W LED SP 221x1556 1 0.039 6.6 43s 209

Page 491: 3F Filippi  "General catalogue 2016"

488

Notes

Page 492: 3F Filippi  "General catalogue 2016"

Credits

The use of text, images, drawings or any other content from this General Catalogue, or their modification or reproduction, in whole or in part, is strictly prohibited without the express authorisation of 3F Filippi S. P.A.Any company or product names or registered trademarks referred to in this publication are the property of their corresponding owners.

Photography

Antonio BragaFabio LercaraIvan RiccardiDaniele Varesano

Page 493: 3F Filippi  "General catalogue 2016"

Headquarters

Via del Savena, 28Zona Industriale “Piastrella”

Pian Di Macina40065 Pianoro - Bologna - Italy

Telephone: +39 051 652 9611Fax: +39 051 775 884

E-mail: [email protected]: www.3f-filippi.com

Page 494: 3F Filippi  "General catalogue 2016"

Acronyms

1x -> 6x Number of lamps 2M 60° specular louvre

2MG 60° specular louvre, high efficiency2S 60° semi-specular louvre

2SG 60° semi-specular louvre, high efficiency2US 60° semi-glossy louvre3AO Matt silver decorative louvre

3DEC White decorative louvreAB White trimAC Low height

AMPIO Wide flow recuperatorAR High energy savingsAS Asymmetric

B WhiteBA Aluminium edge

BAT Batwing distribution - dual asymmetricBL Wide edgeBS Prominent edge

C Compact lampsCD Dual compact lamps

CLO Constant light output (see the section "Management of light")COM Commercial specular/white louvre

CONC Concentrated flow recuperatorCR Fast connectionCT Triple compact lamps

D Curved diffuserD1-10V Dimmable 1 - 10 volt wiring

DA Twin-circuitDALI Dali digital dimmable wiring

DE Dual emissionDI Direct – indirect light output

DR Rectangular diffuserDX RightEEI Energy efficiency index

ENP Non-permanent emergency lightingEP Permanent emergency lighting

EXT ExternalGER Germicidal

GR GreyHCL Human centric lighting (see the section "Management of light")

HF Electronic wiringHO High OutputHS Hard Skin - high chemical resistant body

HST Glass stabilised via heat soak testHT High temperatureIC Luminaire to be installed between two IFC products

Ice Version suitable for refrigeration cells

IFC Luminaire to start or finish a lighting channelII Class ii

IKxx Impact resistanceIND Indirect light outputINT Internal

IPxx Liquid ingress protection L Lenses

LA Wide version luminaireLD Lamps supplied

LED Light emitting diodeLGS Low glaring screen

Lxxxx Appliance length xxxx millimetresME Pomegranate OP Opal

P Surface luminairePC Polycarbonate

E EfficiencyR90 90% efficiencyRFB White steel flow recuperatorRFM Semi-polished aluminium flow recuperator

RFMG High-efficiency specular aluminium flow recuperatorRSP Flow recuperator with prismatic screenRVS Flow recuperator and molded glass

Sensor Sensor (refer to the "Management of light")Sensor CF Sensor with corridor function (refer to the "Management of light")

SK Low glaring opticSL Flat smooth diffuser in methacrylate

SMP Micro-prismatic diffuserSO Pendant luminaire

SOP Opal methacrylate screenSP Flat diffuser, prismatic in methacrylate

SPA Flat diffuser, prismatic methacrylate, lay-in installationSPM Flat diffuser, prismatic methacrylate, microperforated

ST Tight bodySX LeftT5 Fluorescent lamp, T5 ø16 mm

T5-R Circular fluorescent lamp, T5 ø16 mmT8 Fluorescent lamp, T8 ø26 mm

UR95 Resistent to relative humidity up to 95%VDT Optic suitable for use in environments with monitorVOP Opal enamelled glass

VS Moulded glassVSS Laminated moulded glass

VT Transparent glassVTS Transparent laminated glassWW Wall washer distribution

Legend

Symbols

Glow wire resistance temperature

Certification

IP rating of recessed partIP rating of exposed part

Overall IP rating

Luminaire with low-luminance

Overall IK rating

Type of Starter wiring

Luminaires with electronic wiring and limited surface temperature

Protection against electric shock - appliance class

Safety Extra-Low VoltageSeparated power source (Class III)

Page 495: 3F Filippi  "General catalogue 2016"

General Catalogue 20163F Filippi S.p.A. is constantly striving to improve its products.Therefore, it reserves the right to modify the contents of thispublication without prior notice.Check for any updates by visiting our website atwww.3f-filippi.com, or contact our Sales Network.

Sign up to lightUpdate: news, events and new products straight to your inbox. Information at the speed of Light.

Web: www.3f-filippi.comE-mail: [email protected].: +39 051 6529611Fax: +39 051 775884

Head of ce and factoryVia del Savena, 28 - Z.I. Piastrella40065 Pian di Macina - Pianoro (Bologna) - ItalyTax Code. 01033260371 - VAT no. IT00529461204Share Capital € 3,000,000 fully paid upBologna Register of Companies no. 01033260371 -REA (economic administrative index) No. 234613