    Cables

    Issue Draft CDate 2014-03-26

    HUAWEI TECHNOLOGIES CO., LTD.

  • Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved.No part of this document may be reproduced or transmitted in any form or by any means without prior writtenconsent of Huawei Technologies Co., Ltd. Trademarks and Permissions

    and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.All other trademarks and trade names mentioned in this document are the property of their respective holders. NoticeThe purchased products, services and features are stipulated by the contract made between Huawei and thecustomer. All or part of the products, services and features described in this document may not be within thepurchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information,and recommendations in this document are provided "AS IS" without warranties, guarantees or representationsof any kind, either express or implied.

    The information in this document is subject to change without notice. Every effort has been made in thepreparation of this document to ensure accuracy of the contents, but all statements, information, andrecommendations in this document do not constitute a warranty of any kind, express or implied. Huawei Technologies Co., Ltd.Address: Huawei Industrial Base

    Bantian, LonggangShenzhen 518129People's Republic of China

    Website: http://www.huawei.comEmail: [email protected]

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    i

  • About This Document

    OverviewThis document describes information about the cables for the cabinets used in 3900 series basestations. It provides cable lists and illustrates the cable connections and all related cables. Forthe details about the RRU or AAU cables, see the related manual of RRU or AAU hardwaredescription.The exteriors of components or cables in this document are for reference only. The actualexteriors may be different.

    NOTE

    If LTE is used rather than LTE FDD or LTE TDD in this document, the LTE mode can be the LTE FDD modeor LTE TDD mode. If eNodeB is used rather than eNodeB FDD or eNodeB TDD in this document, the eNodeBcan be an eNodeB FDD or a eNodeB TDD.For details about the LampSite solution, see LampSite Hardware Description.

    Product VersionThe following table lists the product versions related to this document.

    Product Name Product VersionBTS3900 V100R009C00

    The mapping single-mode base station versions are:GBTS: V100R016C00eGBTS: V100R016C00NodeB: V200R016C00eNodeB: V100R007C00

    BTS3900ABTS3900LBTS3900ALDBS3900BTS3900C V100R009C00

    The mapping single-mode base station version is:NodeB: V200R016C00

    3900 Series Base StationCables About This Document

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    ii

  • Intended AudienceThis document is intended for:l System engineersl Base station installation engineersl Site maintenance personnel

    Organization1 Changes in 3900 Series Base Station CablesThis chapter describes changes in 3900 Series Base Station Cable Description of each version.2 Cable ListThis chapter describes cable lists for BTS3900, BTS3900L, BTS3900A, BTS3900AL, andBTS3900C base stations.3 Cable ConnectionsThis chapter describes cable connections for 3900 series base station, including power cableconnections, transmission cable connections, monitoring signal cable connections, BBUinterconnection signal cable connections, CPRI cable connections, and RF cable connections.4 PGND CablesPGND cables are classified into PGND cables for cabinets and PGND cables for modules. PGNDcables ensure that cabinets and internal modules are properly grounded and that base stationsrun properly.5 Equipotential CablesEquipotential cables connect the PGND terminals of two cabinets. Equipotential cables ensurethat cabinets are equipotential and that base stations run properly.6 Power CablesThis section describes the exteriors, functions, and pin assignment of power cables in BTS3900Acabinets.7 Transmission CablesThis section describes the exteriors, functions, pin assignment of the transmission cables in acabinet.8 Signal CablesThis section describes the exteriors, functions, pin assignment of all signal cables in BTS3900Acabinets.9 CPRI CablesThis section describes CPRI cables, including CPRI electrical cables and CPRI fiber optic cables.10 RF Cables

    3900 Series Base StationCables About This Document

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    iii

  • This chapter describes the RF cables, including RF jumpers and inter-RFU RF signal cables.

    ConventionsSymbol ConventionsThe symbols that may be found in this document are defined as follows.

    Symbol DescriptionIndicates an imminently hazardous situation which, if notavoided, will result in death or serious injury.

    Indicates a potentially hazardous situation which, if notavoided, could result in death or serious injury.

    Indicates a potentially hazardous situation which, if notavoided, may result in minor or moderate injury.

    Indicates a potentially hazardous situation which, if notavoided, could result in equipment damage, data loss,performance deterioration, or unanticipated results.NOTICE is used to address practices not related to personalinjury.Calls attention to important information, best practices andtips.NOTE is used to address information not related to personalinjury, equipment damage, and environment deterioration.

    General ConventionsThe general conventions that may be found in this document are defined as follows.

    Convention DescriptionTimes New Roman Normal paragraphs are in Times New Roman.Boldface Names of files, directories, folders, and users are in

    boldface. For example, log in as user root.Italic Book titles are in italics.Courier New Examples of information displayed on the screen are in

    Courier New.

    Command ConventionsThe command conventions that may be found in this document are defined as follows.

    3900 Series Base StationCables About This Document

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    iv

  • Convention DescriptionBoldface The keywords of a command line are in boldface.Italic Command arguments are in italics.[ ] Items (keywords or arguments) in brackets [ ] are optional.{ x | y | ... } Optional items are grouped in braces and separated by

    vertical bars. One item is selected.[ x | y | ... ] Optional items are grouped in brackets and separated by

    vertical bars. One item is selected or no item is selected.{ x | y | ... }* Optional items are grouped in braces and separated by

    vertical bars. A minimum of one item or a maximum of allitems can be selected.

    [ x | y | ... ]* Optional items are grouped in brackets and separated byvertical bars. Several items or no item can be selected.

    GUI ConventionsThe GUI conventions that may be found in this document are defined as follows.

    Convention DescriptionBoldface Buttons, menus, parameters, tabs, window, and dialog titles

    are in boldface. For example, click OK.> Multi-level menus are in boldface and separated by the ">"

    signs. For example, choose File > Create > Folder.

    Keyboard OperationsThe keyboard operations that may be found in this document are defined as follows.

    Format DescriptionKey Press the key. For example, press Enter and press Tab.Key 1+Key 2 Press the keys concurrently. For example, pressing Ctrl+Alt

    +A means the three keys should be pressed concurrently.Key 1, Key 2 Press the keys in turn. For example, pressing Alt, A means

    the two keys should be pressed in turn.

    Mouse OperationsThe mouse operations that may be found in this document are defined as follows.

    3900 Series Base StationCables About This Document

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    v

  • Action DescriptionClick Select and release the primary mouse button without moving

    the pointer.Double-click Press the primary mouse button twice continuously and

    quickly without moving the pointer.Drag Press and hold the primary mouse button and move the

    pointer to a certain position.

    3900 Series Base StationCables About This Document

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    vi

  • Contents

    About This Document.....................................................................................................................ii1 Changes in 3900 Series Base Station Cables............................................................................12 Cable List.........................................................................................................................................42.1 BTS3900 Cable List.......................................................................................................................................................52.1.1 BTS3900 (Ver.B) Cable List.......................................................................................................................................52.1.2 BTS3900 (Ver.C) Cable List.....................................................................................................................................122.1.3 BTS3900 (Ver.D) Cable List.....................................................................................................................................192.2 BTS3900L Cable List...................................................................................................................................................292.2.1 BTS3900L (Ver.B) Cable List...................................................................................................................................292.2.2 BTS3900L (Ver.C) Cable List...................................................................................................................................362.2.3 BTS3900L (Ver.D) Cable List..................................................................................................................................442.3 BTS3900A Cable List..................................................................................................................................................522.3.1 BTS3900A (Ver.B) Cable List..................................................................................................................................522.3.2 BTS3900A (Ver.C) Cable List..................................................................................................................................632.3.3 BTS3900A (Ver.D) Cable List..................................................................................................................................752.3.4 BTS3900A(Ver.D_A2) Cable List............................................................................................................................872.3.5 BTS3900A(Ver.D_A1) Cable List............................................................................................................................922.4 BTS3900AL Cable List................................................................................................................................................982.4.1 BTS3900AL (Ver.A) Cable List...............................................................................................................................982.5 DBS3900 Cable Lists.................................................................................................................................................1102.6 BTS3900C Cable List.................................................................................................................................................1152.6.1 BTS3900C WCDMA Cable List.............................................................................................................................1152.6.2 BTS3900C (Ver.C) Cable List................................................................................................................................1213 Cable Connections.....................................................................................................................1293.1 Power Cable Connections...........................................................................................................................................1303.1.1 BTS3900 Power Cable Connections.......................................................................................................................1303.1.2 BTS3900L Power Cable Connections.....................................................................................................................1413.1.3 BTS3900A Power Cable Connections....................................................................................................................1463.1.4 BTS3900AL Power Cable Connections..................................................................................................................1713.1.5 Power Cable Connections in a DBS3900................................................................................................................1763.1.6 BTS3900C Power Cable Connections.....................................................................................................................214

    3900 Series Base StationCables Contents

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    vii

  • 3.2 Transmission Cable Connections...............................................................................................................................2183.2.1 Transmission Cable Connections for a Single-Mode Base Station.........................................................................2183.2.2 Transmission Cable Connections for a Dual-Mode Base Station Using the Co-Transmission Function...............2293.2.3 Transmission Cable Connections for a Dual-Mode Base Station Using the Separate-Transmission Function..........................................................................................................................................................................................2433.2.4 Transmission Cable Connections for a Triple-Mode Base Station.........................................................................2523.2.5 Transmission Cable Connections for a Quadruple-Mode Base Station..................................................................2573.3 Monitoring Signal Cable Connections.......................................................................................................................2583.3.1 BTS3900 Monitoring Signal Cable Connections....................................................................................................2593.3.2 BTS3900L Monitoring Signal Cable Connections..................................................................................................2713.3.3 BTS3900A Monitoring Signal Cable Connections.................................................................................................2773.3.4 BTS3900AL Monitoring Signal Cable Connections...............................................................................................3033.3.5 Monitoring Signal Cable Connections in a DBS3900.............................................................................................3103.3.6 BTS3900C Monitoring Signal Cable Connections.................................................................................................3413.4 Inter-BBU Signal Cable Connections.........................................................................................................................3453.5 CPRI Cable Connections............................................................................................................................................3483.5.1 CPRI Cable Connections for a GSM Base Station..................................................................................................3483.5.2 CPRI Cable Connections for a UMTS Base Station...............................................................................................3523.5.3 CPRI Cable Connections for an LTE FDD and an LTE TDD Base Stations.........................................................3553.5.4 CPRI Cable Connections for a GU and a G*U Base Stations.................................................................................3583.5.5 CPRI Cable Connections for a GL and a G*L Base Stations..................................................................................3643.5.6 CPRI Cable Connections for a UL and a U*L Base Stations..................................................................................3703.5.7 CPRI Cable Connections for a Triple-Mode Base Station......................................................................................3763.5.8 CPRI Cable Connections for a Quadruple-Mode Base Station...............................................................................3873.6 RF Cable Connections................................................................................................................................................3903.6.1 RF Cable Connection Description...........................................................................................................................3913.6.2 RF Cable Connections for the DRFU......................................................................................................................3933.6.3 RF Cable Connections for the GRFU......................................................................................................................3943.6.4 RF Cable Connections for the WRFU.....................................................................................................................3953.6.5 RF Cable Connections for the WRFUa...................................................................................................................3963.6.6 RF Cable Connections for the WRFUd...................................................................................................................3973.6.7 RF Cable Connections for the WRFUe...................................................................................................................3983.6.8 RF Cable Connections for the LRFU......................................................................................................................3993.6.9 RF Cable Connections for the LRFUe....................................................................................................................4003.6.10 RF Cable Connections for the MRFU...................................................................................................................4013.6.11 RF Cable Connections for the MRFUd.................................................................................................................4023.6.12 RF Cable Connections for the MRFUe.................................................................................................................4033.6.13 RF Cable Connections for the CRFUd..................................................................................................................4043.6.14 RF Cable Connections for the CRFUe..................................................................................................................4053.6.15 RF Cable Connections for Mixed RFU Configuration..........................................................................................4064 PGND Cables.............................................................................................................................409

    3900 Series Base StationCables Contents

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    viii

  • 5 Equipotential Cables.................................................................................................................4126 Power Cables..............................................................................................................................4146.1 Power Cables for Power Supply Devices...................................................................................................................4156.1.1 DCDU Power Cables...............................................................................................................................................4156.1.2 EPU/EPS/ETP Power Cables..................................................................................................................................4346.1.3 PDU Power Cables..................................................................................................................................................4526.1.4 Power Cables for Other Power Supply Devices......................................................................................................4576.2 Power Cables for Monitoring Devices.......................................................................................................................4666.2.1 CMUEA Power Cable.............................................................................................................................................4666.2.2 CMUF Power Cable................................................................................................................................................4676.2.3 CCU Power Cable...................................................................................................................................................4686.2.4 HEUA Power Cable.................................................................................................................................................4696.2.5 HEUB Power Cable.................................................................................................................................................4706.3 Power Cables for Temperature Control Devices........................................................................................................4716.3.1 Power Cables for Fan Assemblies...........................................................................................................................4716.3.2 FAU03D-01 Power Cable.......................................................................................................................................4796.3.3 FAU03D-02 Power Cable.......................................................................................................................................4806.3.4 Power Cables for an AC Heater..............................................................................................................................4816.3.5 Power Cable for a Heating Film..............................................................................................................................4836.3.6 Transfer Cable for the Fan in the Front Door..........................................................................................................4846.3.7 Power Cables for the Temperature Control System................................................................................................4856.3.8 HAU01A-01 Power Cable.......................................................................................................................................4866.3.9 Fan Power Cables in an IBBS200D........................................................................................................................4866.3.10 TEC Power Cables in an IBBS200T.....................................................................................................................4896.3.11 Power Cable for a Heat Exchanger in the Front Door...........................................................................................4926.4 Power Cables for Other Devices................................................................................................................................4936.4.1 EMUA/EMUB Power Cable...................................................................................................................................4936.4.2 BBU Power Cable...................................................................................................................................................4956.4.3 RFU Power Cables..................................................................................................................................................4976.4.4 RRU Power Cables..................................................................................................................................................4996.4.5 SOU Power Cable....................................................................................................................................................5016.4.6 SPD Power Cable....................................................................................................................................................5026.4.7 Power Cable for an AC Surge Protection Box........................................................................................................5036.4.8 GATM Power Cable................................................................................................................................................5046.4.9 ODM06D Power Cable...........................................................................................................................................5077 Transmission Cables.................................................................................................................5087.1 E1/T1 Cable................................................................................................................................................................5107.2 E1/T1 Surge Protection Transfer Cable......................................................................................................................5137.3 FE/GE Fiber Optic Cable...........................................................................................................................................5147.4 Interconnection Cable Between FE/GE Electrical Ports............................................................................................515

    3900 Series Base StationCables Contents

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    ix

  • 7.5 Interconnection Cable Between FE/GE Optical Ports................................................................................................5157.6 FE/GE Ethernet Cable................................................................................................................................................5167.7 FE/GE Surge Protection Transfer Cable....................................................................................................................5178 Signal Cables..............................................................................................................................5198.1 Signal Cables for Power Devices...............................................................................................................................5208.1.1 PMU-CCU Monitoring Signal Cable......................................................................................................................5208.1.2 PMU 11A-CMUEA Monitoring Signal Cable........................................................................................................5218.1.3 PMU 01B-BBU Monitoring Signal Cable...............................................................................................................5218.1.4 PMU 11A-BBU Monitoring Signal Cable..............................................................................................................5228.1.5 PMU 11A-HEUB Monitoring Signal Cable............................................................................................................5238.1.6 Surge Protection Alarm Cable for the DCDU-13A.................................................................................................5248.1.7 Monitoring Signal Cable for the DCDU-03B..........................................................................................................5258.1.8 PSU (EPW25-24S48D) Monitoring Signal Cable...................................................................................................5258.1.9 PSU (EPW25-24S48D) In-Position Signal Cable...................................................................................................5268.2 Signal Cables for Monitoring Devices.......................................................................................................................5278.2.1 PMU-HEUA Monitoring Signal Cable...................................................................................................................5278.2.2 APMI-BBU Monitoring Signal Cable.....................................................................................................................5288.2.3 Signal Cables for connecting Cascaded CCUs........................................................................................................5298.2.4 CCU-BBU Monitoring Signal Cable.......................................................................................................................5308.2.5 Monitoring Signal Cable between Cascaded CMUAs............................................................................................5318.2.6 Monitoring Signal Cable Between Cascaded CMUEs............................................................................................5328.2.7 Monitoring Signal Cable Between Cascaded CMUEAs.........................................................................................5338.2.8 Signal Cables for connecting Cascaded HAU01A-01s...........................................................................................5348.2.9 HEUB-BBU Monitoring Signal Cable....................................................................................................................5358.2.10 HEUA-BBU Monitoring Signal Cable..................................................................................................................5368.2.11 CMUEA-CCU Monitoring Signal Cable..............................................................................................................5368.2.12 CMUF-CCU Monitoring Signal Cable..................................................................................................................5378.2.13 CMUEA-BBU Monitoring Signal Cable..............................................................................................................5388.2.14 HAU01A-01 Monitoring Signal Cable..................................................................................................................5398.2.15 FMUC-BBU Monitoring Signal Cable..................................................................................................................5408.2.16 FMUE-BBU Monitoring Signal Cable..................................................................................................................5418.2.17 FMUEA-BBU Monitoring Signal Cable...............................................................................................................5428.2.18 Monitoring Signal Cable for the Battery Cabinet..................................................................................................5438.2.19 BBU Alarm Cable.................................................................................................................................................5448.3 Signal Cables for Temperature Control Devices........................................................................................................5468.3.1 Monitoring Signal Cable Between Cascaded Fan Assemblies................................................................................5468.3.2 FAU03D-01 Monitoring Signal Cable....................................................................................................................5478.3.3 FAU03D-02 Monitoring Signal Cable....................................................................................................................5488.3.4 Monitoring Signal Cable Between Cascaded FANs................................................................................................5498.3.5 HEUB-FAU01D-01 Monitoring Signal Cable........................................................................................................5508.3.6 Monitoring Signal Cable Between Cascaded FAN 03B Units................................................................................551

    3900 Series Base StationCables Contents

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    x

  • 8.3.7 Monitoring Signal Cable Between Cascaded FAN 03C Units................................................................................5528.3.8 Monitoring Signal Cable for the OMB Fan Assembly............................................................................................5538.3.9 Monitoring Signal Cables for the Temperature Sensor...........................................................................................5538.3.10 HAU01A-01 Monitoring Signal Cable..................................................................................................................5558.3.11 Monitoring Signal Transfer Cable for the Fan in the Front Door.........................................................................5578.3.12 Monitoring Signal Cable for the Heat Exchanger.................................................................................................5588.3.13 TEC Alarm Transfer Cable for the IBBS2.2.........................................................................................................5598.4 Signal Cables for Other Devices................................................................................................................................5608.4.1 Monitoring Signal Cable for the Door Status Sensor..............................................................................................5608.4.2 ELU Signal Cable....................................................................................................................................................5638.4.3 Monitoring Signal Cables for the IBBS Door Control and Temperature Sensor....................................................5658.4.4 EMUA/EMUB Monitoring Signal Cable................................................................................................................5668.4.5 EMU Monitoring Signal Cable................................................................................................................................5678.4.6 Monitoring Signal Cable for the AC Surge Protection Module..............................................................................5688.4.7 Alarm Signal Cable for the AC Surge Protection Box............................................................................................5698.4.8 Monitoring Signal Cable for the Surge Protection Box..........................................................................................5698.4.9 RRU AISG Multi-Wire Cable.................................................................................................................................5708.4.10 RRU AISG Extension Cable.................................................................................................................................5718.4.11 GPS Clock Signal Cable........................................................................................................................................5728.4.12 GPS Jumper...........................................................................................................................................................5728.4.13 Inter-BBU Signal Cables.......................................................................................................................................5738.4.14 Cable Between Two Combined Base Stations......................................................................................................5758.4.15 Adapter Used for Local Maintenance....................................................................................................................5768.4.16 GATM Monitoring Signal Cable...........................................................................................................................5778.4.17 CMUA-GATM Monitoring Signal Cable.............................................................................................................5788.4.18 CMUE-GATM Monitoring Signal Cable..............................................................................................................5798.4.19 CMUEA-GATM Monitoring Signal Cable...........................................................................................................5808.4.20 FMUC-GATM Monitoring Signal Cable..............................................................................................................5818.4.21 FMUE-GATM Monitoring Signal Cable..............................................................................................................5828.4.22 RET Control Signal Cable.....................................................................................................................................5838.4.23 ODM06D Surge Protection Alarm Cable..............................................................................................................5849 CPRI Cables................................................................................................................................5859.1 CPRI Electrical Cable.................................................................................................................................................5869.2 CPRI Fiber Optic Cable..............................................................................................................................................58610 RF Cables...................................................................................................................................59110.1 RF Jumpers...............................................................................................................................................................59210.2 Inter-RFU RF Signal Cable......................................................................................................................................593

    3900 Series Base StationCables Contents

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    xi

  • 1 Changes in 3900 Series Base Station CablesThis chapter describes changes in 3900 Series Base Station Cable Description of each version.

    Draft C (2014-03-26)This is a draft.Compared with the issues Draft B (2014-02-28), this issue is added with the following topics:l Power Cable Connections in an IBC10 Used by a DBS3900l Monitoring Signal Cable Connections in an IBC10 Used by a DBS3900l 6.3.3 FAU03D-02 Power Cablel 8.3.3 FAU03D-02 Monitoring Signal CableCompared with the issues Draft B (2014-02-28), this issue includes the following changes.

    Topic Change DescriptionDCDU-12C Power Cables Added the descriptions of the IBC10.4 PGND Cables8.3.9 Monitoring Signal Cables for theTemperature Sensor

    Compared with the issues Draft B (2014-02-28), no topic is deleted from this issue.

    Draft B (2014-02-28)This is a draft.Compared with the issues Draft A (2014-01-20), this issue does not include any new informationand does not exclude any information.Compared with the issues Draft A (2014-01-20), this issue includes the following changes.

    3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    1

  • Topic Change DescriptionAbout This Document Added the description of the LampSite

    solution.

    Darft A (2014-01-20)This is a draft.Compared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue is added with thefollowing topics:l 2.5 DBS3900 Cable Listsl Power Cable for the DC Junction Box in a BTS3900ALl 6.4.9 ODM06D Power Cablel 8.4.23 ODM06D Surge Protection Alarm CableCompared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue incorporates thefollowing changes:

    Topic Change Descriptionl 3.2 Transmission Cable Connections

    and its child topics.l 3.5 CPRI Cable Connections and its

    child topics.

    Added the cable connections when BBU3910is configured.

    l 2.3.1 BTS3900A (Ver.B) Cable Listl 2.3.2 BTS3900A (Ver.C) Cable Listl 2.3.3 BTS3900A (Ver.D) Cable Listl 2.4.1 BTS3900AL (Ver.A) Cable Listl 6.4.1 EMUA/EMUB Power Cablel 8.4.4 EMUA/EMUB Monitoring Signal

    Cable

    Added the EMUB power cable and EMUBmonitoring signal cable.

    The whole document Renamed all EPC6 connectors in thisdocument EPC4 connectors.

    l 2.1.3 BTS3900 (Ver.D) Cable Listl 2.2.3 BTS3900L (Ver.D) Cable List

    Added the cables when the BTS3900 (Ver.D)and BTS3900L (Ver.D) use the IMS06.

    3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    2

  • Topic Change Descriptionl BTS3900 (Ver.D) Power Cable

    Connectionsl BTS3900 (Ver.D) Monitoring Signal

    Cable Connectionsl BTS3900L (Ver.D) Power Cable

    Connectionsl BTS3900L (Ver.D) Monitoring Signal

    Cable Connections

    Added the cable connections when theBTS3900 (Ver.D) and BTS3900L (Ver.D)use the IMS06.

    l 2.1.2 BTS3900 (Ver.C) Cable Listl 2.2.2 BTS3900L (Ver.C) Cable List

    Deleted the DCDU-12B power cable.

    DCDU-11B Power Cable Deleted scenarios where a DCDU-11B isinstalled in a cabinet.

    DCDU-12B Power Cable Deleted scenarios where a DCDU-12B isinstalled on a wall.

    Compared with multimode base station version V100R008C00, WCDMA-NodeBV200R015C00, GSM-BTS V100R015C00, eNodeB V100R006C00, this issue excludes thefollowing information:l BusBar Power Cablesl EPU03A-20 Power Cables

    3900 Series Base StationCables 1 Changes in 3900 Series Base Station Cables

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    3

  • 2 Cable ListAbout This Chapter

    This chapter describes cable lists for BTS3900, BTS3900L, BTS3900A, BTS3900AL, andBTS3900C base stations.

    2.1 BTS3900 Cable ListThis section describes cable lists when the BTS3900 is configured with BTS3900 (Ver.B),BTS3900 (Ver.C), and BTS3900 (Ver.D) cabinets.2.2 BTS3900L Cable ListThis section describes cable lists when the BTS3900L is configured with BTS3900L (Ver.B),BTS3900L (Ver.C), and BTS3900L (Ver.D) cabinets.2.3 BTS3900A Cable ListThis section describes cable lists when the BTS3900A is configured with BTS3900A (Ver.B),BTS3900A (Ver.C), BTS3900A(Ver.D), and enhanced cabinets.2.4 BTS3900AL Cable ListThis section describes the list of BTS3900AL cables.2.5 DBS3900 Cable ListsThe DBS3900 cable lists include the lists of cables for the cabinets used by the DBS3900, BBUcable list, and RRU cable list.2.6 BTS3900C Cable ListThis section describes cable lists when the BTS3900C is configured with different types ofcabinets.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    4

  • 2.1 BTS3900 Cable ListThis section describes cable lists when the BTS3900 is configured with BTS3900 (Ver.B),BTS3900 (Ver.C), and BTS3900 (Ver.D) cabinets.

    2.1.1 BTS3900 (Ver.B) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.

    PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.

    Table 2-1 PGND cables and equipotential cableCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    PGND cablefor thecabinet

    OT terminal Groundterminal onthe cabinet

    OT terminal Externalground bar

    5Equipotential Cables

    OT terminal Wiringterminal fortheequipotential cable

    OT terminal Wiringterminal fortheequipotentialcable

    Cablesinstalledbeforedelivery

    PGND cablefor a module

    OT terminal Groundterminal on amodule

    OT terminal Groundterminal forthe PGNDcable in thecabinet

    Power CablesThe following table describes the power cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    5

  • Table 2-2 Power cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    DCDU-01PowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-01

    l Bluewire:NEG(-)terminalon theDCDU-01

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    EPS24S48100DC PowerCable

    OT terminal Power inputterminal fortheEPS24S48100DCsubrack

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    EPS4890PowerCable

    OT terminal Power inputterminal forthe EPS4890subrack

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    6.4.4 RRUPowerCables

    OT terminal One of theLOAD0 toLOAD5ports on theDCDU-03B

    Dependingon the RRUmodel

    Power porton an RRU

    GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Parallelterminal

    SPARE1 orSPARE2port on theDCDU-01

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    6

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionDCDU-03BPowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-03B

    l Bluewire:NEG(-)terminalon theDCDU-03B

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    Cablesinstalledbeforedelivery

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onan RFU

    Parallelterminal

    One of theRFU0 toRFU5 portson theDCDU-01

    FAN PowerCables

    3V3connector

    -48V port onthe FAN

    Parallelterminal

    FAN port ontheDCDU-01

    6.4.2 BBUPowerCable

    3V3connector

    -48V port onthe UPEU

    Parallelterminal

    BBU port ontheDCDU-01

    DCDU-01PowerCableFor theBTS3900+24V DCcabinet

    OT terminal RTN(+) andNEG(-)terminals ontheDCDU-01

    OT terminal RTN(+) andLOAD(-)terminals ontheEPS24S48100DCsubrack

    DCDU-01PowerCableFor theBTS3900AC cabinet

    OT terminal RTN(+) andNEG(-)terminals ontheDCDU-01

    OT terminal LOAD1(-) orLOAD2(-)and RTN(+)terminals onthe EPS4890subrack

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    7

  • Transmission CablesThe following table describes the transmission cables.

    Table 2-3 Transmission cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    7.1 E1/T1Cable

    DB26 maleconnector

    E1/T1 porton theGTMU,WMPT, orUTRP

    Dependingon theexternalequipment

    Externaltransmissionequipment

    7.6 FE/GEEthernetCable

    RJ45connector

    FE0 port onthe GTMU,WMPT,UMPT,LMPT, orUTRP

    RJ45connector

    Routingdevice

    7.3 FE/GEFiber OpticCable

    LCconnector

    SFP0 orSFP1 port onthe GTMU,WMPT,UMPT, orUTRP

    l FCconnector

    l SCconnector

    l LCconnector

    Routingdevice

    Cablesinstalledbeforedelivery

    7.4Interconnection CableBetweenFE/GEElectricalPorts

    RJ45connector

    FE0 port onthe GTMU

    RJ45connector

    FE0 port onthe WMPT

    7.5Interconnection CableBetweenFE/GEOpticalPorts

    LCconnector

    FE1 port onthe GTMU

    LCconnector

    FE1 port onthe WMPT

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    8

  • Signal CablesThe following table describes the signal cables.

    Table 2-4 Signal cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    8.4.5 EMUMonitoringSignalCable

    DB9 maleconnector

    RS485 porton the EMU

    RJ45connector

    MON1 porton the UPEUor UEIU

    8.2.19 BBUAlarmCable

    RJ45connector

    EXT-ALM0port on theUPEU orUEIU

    RJ45connector

    Externalalarm device

    8.4.11 GPSClockSignalCable

    SMA maleconnector

    GPS port onthe USCU

    Type Nfemaleconnector

    GPS surgeprotector

    RETControlSignalCable

    SMA elbowmaleconnector

    ANT0 toANT5 portson theGATM

    SMA straightmaleconnector

    DC/OOKport on theDIN Bias-Tee

    GATMMonitoringSignalCable

    RJ45connector

    COM1 porton theGATM

    RJ45connector

    MON1 porton the UPEUor MON0port on theUEIU

    FMUC-GATMMonitoringSignalCable

    RJ45connector

    COM2 porton theGATM

    RJ45connector

    COM_INport on thelower-levelFAN

    8.4.15AdapterUsed forLocalMaintenance

    USBconnector

    USB(1) porton theUMPT in theBBU

    Networkconnector

    Networkcable

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    9

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionCablesinstalledbeforedelivery

    8.1.3 PMU01B-BBUMonitoringSignalCable

    RJ45connector

    COM_INport on thePMU 01B

    RJ45connector

    MON1 porton the UPEU

    8.1.9 PSU(EPW25-24S48D) In-PositionSignalCable

    Cord endterminal

    ALMterminal ontheEPS24S48100DCsubrack

    RJ45connector

    EXT-ALM0port on theUPEU

    8.1.8 PSU(EPW25-24S48D)MonitoringSignalCable

    RJ45connector

    PRESENTport on theEPS24S48100DCsubrack

    RJ45connector

    EXT-ALM1port on theUPEU

    8.2.15FMUC-BBUMonitoringSignalCable

    RJ45connector

    COM_INport on theFAN

    RJ45connector

    MON0 porton the UPEUor UEIU

    8.3.4MonitoringSignalCableBetweenCascadedFANs

    RJ45connector

    COM_OUTport on theupper-levelFANNOTE

    The upper-level FANcommunicates with theBBUdirectly.

    RJ45connector

    COM_INport on thelower-levelFANNOTE

    The lower-level FANcommunicates with theBBUthrough theupper-levelFAN.

    8.4.2 ELUSignalCable

    RJ45connector

    ELU RJ45connector

    SENSORport on theFAN

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    10

  • NOTE

    a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.

    CPRI Electrical CablesThe following table describes the CPRI electrical cables.

    Table 2-5 CPRI electrical cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    9.1 CPRIElectricalCable

    SFP20 maleconnector

    CPRI port onthe GTMU,UBRI,WBBP, orLBBP

    SFP20 maleconnector

    CPRI port onan RFU

    Cablesinstalledbeforedelivery

    If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.

    RF CablesThe following table describes the RF cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    11

  • Table 2-6 RF cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    10.1 RFJumpers

    DIN elbowmaleconnector

    ANT_TX/RXA orANT_RXBport on anRFU

    DIN straightmaleconnector

    l Feeder oftheantennasystem(noGATMconfigured)

    l ANT porton theBias-Tee(GATMconfigured)

    Cablesinstalledbeforedelivery

    10.2 Inter-RFU RFSignalCable

    QMA elbowmaleconnector

    RX OUTAport on anRFU

    QMA elbowmaleconnector

    RX INB porton anotherRFU

    2.1.2 BTS3900 (Ver.C) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.

    PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.

    Table 2-7 PGND cables and equipotential cableCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    PGND cablefor thecabinet

    OT terminal Groundterminal onthe cabinet

    OT terminal Externalground bar

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    12

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position5Equipotential Cables

    OT terminal Wiringterminal fortheequipotential cable

    OT terminal Wiringterminal fortheequipotentialcable

    Cablesinstalledbeforedelivery

    PGND cablefor a module

    OT terminal Groundterminal on amodule

    OT terminal Groundterminal forthe PGNDcable in thecabinet

    Power CablesThe following table describes the power cables.

    Table 2-8 Power cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    DCDU-11APowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU

    l Bluewire:NEG(-)terminalon theDCDU

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    ETP48150-A3 PowerCable

    OT terminal Power inputterminal fortheETP48150-A3 subrack

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    13

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position6.4.4 RRUPowerCables

    Tool-lessfemaleconnector(pressfittype)

    One of theLOAD0 toLOAD5ports on theDCDU-11B

    Dependingon the RRUmodel

    Power porton an RRU

    GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Tool-lessfemaleconnector(pressfittype)

    LOAD8 orLOAD9 porton theDCDU-11A

    DCDU-11BPowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-11B

    l Bluewire:NEG(-)terminalon theDCDU-11B

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    Cablesinstalledbeforedelivery

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onthe RFU

    Tool-lessfemaleconnector(pressfittype)

    One of theLOAD0 toLOAD5ports on theDCDU-11A

    FAN 03BPowerCable

    3V3connector

    -48V port onthe FAN 03B

    Tool-lessfemaleconnector(pressfittype)

    LOAD6 porton theDCDU-11A

    6.4.2 BBUPowerCable

    3V3connector

    -48V port onthe UPEU

    Tool-lessfemaleconnector(pressfittype)

    LOAD7 orLOAD8 porton theDCDU-11A

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    14

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionETP48150-A3 PowerCable(Black)

    OT terminal RTN(+)terminal ontheDCDU-11A

    OT terminal RTN(+)power outputterminal fortheETP48150-A3 subrack

    ETP48150-A3 PowerCable(Blue)

    OT terminal NEG(-)terminal ontheDCDU-11A

    OT terminal NEG(-)power outputterminal fortheETP48150-A3 subrack

    Transmission CablesThe following table describes the transmission cables.

    Table 2-9 Transmission cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    7.1 E1/T1Cable

    DB26 maleconnector

    E1/T1 porton theGTMU,WMPT, orUTRP

    Dependingon theexternalequipment

    Externaltransmissionequipment

    7.6 FE/GEEthernetCable

    RJ45connector

    FE0 port onthe GTMU,WMPT,LMPT, orUTRP

    RJ45connector

    Externaltransmissionequipment

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    15

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position7.3 FE/GEFiber OpticCable

    LCconnector

    SFP0 orSFP1 port onthe GTMU,WMPT,LMPT, orUTRP

    l FCconnector

    l SCconnector

    l LCconnector

    Externaltransmissionequipment

    Cablesinstalledbeforedelivery

    7.4Interconnection CableBetweenFE/GEElectricalPorts

    RJ45connector

    FE0 port onthe GTMU

    RJ45connector

    FE0 port onthe WMPT

    7.5Interconnection CableBetweenFE/GEOpticalPorts

    LCconnector

    FE1 port onthe GTMU

    LCconnector

    FE1 port onthe WMPT

    Signal CablesThe following table describes the signal cables.

    Table 2-10 Signal cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    8.4.5 EMUMonitoringSignalCable

    DB9 maleconnector

    RS485 porton the EMU

    RJ45connector

    MON1 porton the UPEUor UEIU

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    16

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position8.2.19 BBUAlarmCable

    RJ45connector

    EXT-ALM0port on theUPEU orUEIU

    RJ45connector

    Externalalarm device

    8.4.11 GPSClockSignalCable

    SMA maleconnector

    GPS port onthe USCU

    Type Nfemaleconnector

    GPS surgeprotector

    RETControlSignalCable

    SMA elbowmaleconnector

    ANT0 toANT5 portson theGATM

    SMA straightmaleconnector

    DC/OOKport on theDIN Bias-Tee

    GATMMonitoringSignalCable

    RJ45connector

    COM1 porton theGATM

    RJ45connector

    MON0 orMON1 porton the UPEU

    FMUE-GATMMonitoringSignalCable

    RJ45connector

    COM2 porton theGATM

    RJ45connector

    COM IN porton the lower-level FAN03B

    8.3.6MonitoringSignalCableBetweenCascadedFAN 03BUnits

    RJ45connector

    COM OUTport on theupper-levelFAN 03BNOTE

    The upper-level FAN03Bcommunicates with theBBUdirectly.

    RJ45connector

    COM IN porton the lower-level FAN03BNOTE

    The lower-level FAN03Bcommunicates with theBBUthrough theupper-levelFAN 03B.

    8.4.15AdapterUsed forLocalMaintenance

    USBconnector

    USB(1) porton theUMPT in theBBU

    Networkconnector

    Networkcable

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    17

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionCablesinstalledbeforedelivery

    8.1.3 PMU01B-BBUMonitoringSignalCable

    RJ45connector

    COM_INport on theleft side ofthe PMU01B

    RJ45connector

    MON1 porton the UPEU

    8.2.16FMUE-BBUMonitoringSignalCable

    RJ45connector

    COM IN porton the FAN03B

    RJ45connector

    MON0 porton the UPEUor UEIUNOTE

    If no BBU isinstalled inthe cabinet,bind thecable on theright side ofthe cabinet.

    8.4.2 ELUSignalCable

    RJ45connector

    ELU RJ45connector

    SENSORport on theFAN 03B

    NOTE

    a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.

    CPRI Electrical CablesThe following table describes the CPRI electrical cables.

    Table 2-11 CPRI electrical cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cablesinstalledbeforedelivery

    9.1 CPRIElectricalCable

    SFP20 maleconnector

    CPRI port onthe GTMU,WBBP, orLBBP

    SFP20 maleconnector

    CPRI port onan RFU

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    18

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionCables to beinstalledonsite

    If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.

    RF CablesThe following table describes the RF cables.

    Table 2-12 RF cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    10.1 RFJumpers

    DIN elbowmaleconnector

    ANT_TX/RXA orANT_RXBport on anRFU

    DIN straightmaleconnector

    l Feeder oftheantennasystem(noGATMconfigured)

    l ANT porton theBias-Tee(GATMconfigured)

    Cablesinstalledbeforedelivery

    10.2 Inter-RFU RFSignalCable

    QMA elbowmaleconnector

    RX OUTAport on anRFU

    QMA elbowmaleconnector

    RX INB porton anotherRFU

    2.1.3 BTS3900 (Ver.D) Cable ListThe BTS3900 cables include PGND cables, equipotential cable, power cables, transmissioncables, signal cables, CPRI electrical cables, and RF cables.

    PGND Cables and Equipotential CableThe following table describes the PGND cables and equipotential cable.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    19

  • Table 2-13 PGND cables and equipotential cableCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    4 PGNDCablesFor thecabinet

    OT terminal Groundterminal onthe cabinet

    OT terminal Externalground bar

    5Equipotential CablesBetween thecabinets

    OT terminal Wiringterminal fortheequipotential cable

    OT terminal Wiringterminal fortheequipotentialcable

    Cablesinstalledbeforedelivery

    4 PGNDCablesFor a module

    OT terminal Groundterminal on amodule

    OT terminal Groundterminal forthe PGNDcable in thecabinet

    Power CablesThe following table describes the power cables for an AC-powered BTS3900.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    20

  • Table 2-14 Power cables for an AC-powered BTS3900Category Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    DCDU-12APowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-12A

    l Bluewire:NEG(-)terminalon theDCDU-12A

    OT terminal l Blackwire:RTN(+)terminalon theRFC2terminalfor theEPU05A-02subrack

    l Bluewire:NEG(-)terminalon theRFC2terminalfor theEPU05A-02subrack

    EPU05A-02PowerCable

    OT terminal AC inputterminal fortheEPU05A-02subrack

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    21

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionDCDU-12BPowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-12B

    l Bluewire:NEG(-)terminalon theDCDU-12B

    OT terminal l Blackwire:RTN(+)terminalon theRFC1 fortheEPU05A-02subrack

    l Bluewire:NEG(-)terminalon theRFC1 fortheEPU05A-02subrack

    GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Parallelterminal

    LOAD8 orLOAD9 porton theDCDU-12A

    6.4.4 RRUPowerCables

    EPC5connector

    One of theLOAD0 toLOAD5ports on theDCDU-12B

    Dependingon the RRUmodel

    Power porton an RRU

    EPC4connector

    One of theLOAD6 toLOAD8ports on theDCDU-12B

    Dependingon the RRUmodel

    Power porton an RRU

    Cablesinstalledbeforedelivery

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onan RFU

    EPC4connector

    One of theLOAD0 toLOAD5ports on theDCDU-12A

    FAN 03CPowerCable

    3V3connector

    -48V port onthe FAN 03C

    EPC4connector

    LOAD6 porton theDCDU-12A

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    22

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position6.4.2 BBUPowerCable

    3V3connector

    -48V port onthe UPEU

    EPC4connector

    LOAD7 orLOAD8 porton theDCDU-12A

    The following table describes the power cables for a DC-powered BTS3900.

    Table 2-15 Power cables for a DC-powered BTS3900Category Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    DCDU-12APowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-12A

    l Bluewire:NEG(-)terminalon theDCDU-12A

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    6.4.4 RRUPowerCables

    EPC5connector

    One of theLOAD0 toLOAD5ports on theDCDU-12B

    Dependingon the RRUmodel

    Power porton an RRU

    EPC4connector

    One of theLOAD6 toLOAD8ports on theDCDU-12B

    Dependingon the RRUmodel

    Power porton an RRU

    GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Parallelterminal

    LOAD8 orLOAD9 porton theDCDU-12A

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    23

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n PositionDCDU-12BPowerCable

    OT terminal l Blackwire:RTN(+)terminalon theDCDU-12B

    l Bluewire:NEG(-)terminalon theDCDU-12B

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    Cablesinstalledbeforedelivery

    4 PGNDCablesFor a module

    OT terminal Groundterminal on amodule

    OT terminal Groundterminal forthe PGNDcable in thecabinet

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onan RFU

    EPC4connector

    One of theLOAD0 toLOAD5ports on theDCDU-12A

    FAN 03CPowerCable

    3V3connector

    -48V port onthe FAN 03C

    EPC4connector

    LOAD6 porton theDCDU-12A

    6.4.2 BBUPowerCable

    3V3connector

    -48V port onthe UPEU

    EPC4connector

    LOAD7 orLOAD8 porton theDCDU-12A

    Transmission CablesThe following table describes the transmission cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    24

  • Table 2-16 Transmission cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    7.1 E1/T1Cable

    DB26 maleconnector

    E1/T1 porton theGTMU,WMPT, orUTRP

    Dependingon theexternalequipment

    Externaltransmissionequipment

    7.6 FE/GEEthernetCable

    RJ45connector

    FE0 port onthe GTMU,WMPT,LMPT, orUTRP

    RJ45connector

    Externaltransmissionequipment

    7.3 FE/GEFiber OpticCable

    LCconnector

    SFP0 orSFP1 port onthe GTMU,WMPT,LMPT, orUTRP

    l FCconnector

    l SCconnector

    l LCconnector

    Externaltransmissionequipment

    Cablesinstalledbeforedelivery

    7.4Interconnection CableBetweenFE/GEElectricalPorts

    RJ45connector

    FE0 port onthe GTMU

    RJ45connector

    FE0 port onthe WMPT

    7.5Interconnection CableBetweenFE/GEOpticalPorts

    LCconnector

    FE1 port onthe GTMU

    LCconnector

    FE1 port onthe WMPT

    Signal CablesThe following table describes the signal cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    25

  • Table 2-17 Signal cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    8.4.5 EMUMonitoringSignalCable

    DB9 maleconnector

    RS485 porton the EMU

    RJ45connector

    MON1 porton the UPEUor UEIU

    8.2.19 BBUAlarmCable

    RJ45connector

    EXT-ALM0port on theUPEU orUEIU

    RJ45connector

    Externalalarm device

    8.4.11 GPSClockSignalCable

    SMA maleconnector

    GPS port onthe USCU

    Type Nfemaleconnector

    GPS surgeprotector

    RETControlSignalCable

    SMA elbowmaleconnector

    ANT0 toANT5 portson theGATM

    SMA straightmaleconnector

    DC/OOKport on theDIN Bias-Tee

    GATMMonitoringSignalCable

    RJ45connector

    COM1 porton theGATM

    RJ45connector

    MON0 orMON1 porton the UPEU

    CMUEA-GATMMonitoringSignalCable

    RJ45connector

    COM2 porton theGATM

    RJ45connector

    COM IN porton the lower-level FAN03C

    8.3.7MonitoringSignalCableBetweenCascadedFAN 03CUnits

    RJ45connector

    COM OUTport on theupper-levelFAN 03CNOTE

    The upper-level FAN03Ccommunicates with theBBUdirectly.

    RJ45connector

    COM IN porton the lower-level FAN03CNOTE

    The lower-level FAN03Ccommunicates with theBBUthrough theupper-levelFAN 03C.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    26

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position8.4.13 Inter-BBU SignalCables

    DLCconnector

    One of theM0 to M4ports on theUCIU in theBBU

    DLCconnector

    l CI port ontheUMPT inthe BBU

    l S0 porton theUCIU inthe BBU

    8.4.14 CableBetweenTwoCombinedBaseStations

    DB15 maleconnector

    GCK port onthe UCIU inthe BBU

    MD36 maleconnector

    CKB1 orCKB2 porton the DCTB

    8.4.15AdapterUsed forLocalMaintenance

    USBconnector

    USB(1) porton theUMPT in theBBU

    Networkconnector

    Networkcable

    Cablesinstalledbeforedelivery

    8.1.4 PMU11A-BBUMonitoringSignalCable

    RJ45connector

    COM_INport on theleft side ofthe PMU11A

    RJ45connector

    MON1 porton the UPEU

    8.2.17FMUEA-BBUMonitoringSignalCable

    RJ45connector

    COM IN porton the FAN03C

    RJ45connector

    MON0 porton the UPEUor UEIUNOTE

    If no BBU isinstalled inthe cabinet,bind thecable on theright side ofthe cabinet.

    8.4.2 ELUSignalCable

    RJ45connector

    ELU RJ45connector

    SENSORport on theFAN 03C

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    27

  • NOTE

    a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.

    CPRI Electrical CablesThe following table describes the CPRI electrical cables.

    Table 2-18 CPRI electrical cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cablesinstalledbeforedelivery

    9.1 CPRIElectricalCable

    SFP20 maleconnector

    CPRI port onthe GTMU,WBBP, orLBBP

    SFP20 maleconnector

    CPRI port onan RFU

    Cables to beinstalledonsite

    If boards and modules have been installed in a BTS3900 cabinet beforedelivery, CPRI electrical cables are also installed in the cabinet beforedelivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.

    RF CablesThe following table describes the RF cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    28

  • Table 2-19 RF cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    10.1 RFJumpers

    DIN elbowmaleconnector

    ANT_TX/RXA orANT_RXBport on anRFU

    DIN straightmaleconnector

    l Feeder oftheantennasystem(noGATMconfigured)

    l ANT porton theBias-Tee(GATMconfigured)

    Cablesinstalledbeforedelivery

    10.2 Inter-RFU RFSignalCable

    QMA elbowmaleconnector

    RX OUTAport on anRFU

    QMA elbowmaleconnector

    RX INB porton anotherRFU

    2.2 BTS3900L Cable ListThis section describes cable lists when the BTS3900L is configured with BTS3900L (Ver.B),BTS3900L (Ver.C), and BTS3900L (Ver.D) cabinets.

    2.2.1 BTS3900L (Ver.B) Cable ListThe BTS3900L cables are the PGND cables, power cables, transmission cables, CPRI cables,signal cables, and RF cables.

    PGND CablesThe following table describes the PGND cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    29

  • Table 2-20 PGND cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    PGND cablefor thecabinet

    OT terminal(M8)

    Groundterminal onthe cabinet

    OT terminal(M8)

    Externalground bar

    Cablesinstalledbeforedelivery

    PGND cablefor a module

    OT terminal(M4)

    Groundterminal on amodule

    OT terminal(M4)

    Groundterminal onthe cabinet

    Power CablesThe following table describes the power cables.

    Table 2-21 Power cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    DCDU-01PowerCable

    OT terminal(M6)

    l Blackwire:RTN(+)terminalon theDCDU-01

    l Bluewire:NEG(-)terminalon theDCDU-01

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    6.4.4 RRUPowerCables(optional)

    OT terminal(M4)

    One of theLOAD0 toLOAD5ports on theDCDU-03B

    Dependingon the RRUmodel

    Power porton an RRU

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    30

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position6.4.8 GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Parallelterminal

    SPARE1 orSPARE2port on theDCDU-01

    DCDU-03BPowerCable(optional)

    OT terminal(M6)

    l Blackwire:RTN(+)terminalon theDCDU-03B

    l Bluewire:NEG(-)terminalon theDCDU-03B

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    Cablesinstalledbeforedelivery

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onthe RFU

    Parallelterminal

    One of theRFU0 toRFU5 portson theDCDU-01

    FAN PowerCables

    3V3connector

    -48V port onthe fanassembly

    Parallelterminal

    FAN port ontheDCDU-01

    6.4.2 BBUPowerCable

    3V3connector

    PWR port onthe UPEU

    Parallelterminal

    BBU port ontheDCDU-01

    Transmission CablesThe following table shows the transmission cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    31

  • Table 2-22 Transmission cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    7.1 E1/T1Cable

    DB26 maleconnector

    E1/T1 porton theGTMU,WMPT,UMPT, orUTRP

    Dependingon theexternaltransmissionequipment

    Externaltransmissionequipment

    7.6 FE/GEEthernetCable

    RJ45connector

    FE or FE/GEelectricalport on theGTMU,WMPT,UMPT,LMPT, orUTRP

    RJ45connector

    Externaltransmissionequipment

    7.3 FE/GEFiber OpticCable

    LCconnector

    l FE or FE/GEopticalport ontheGTMU,WMPT,UMPT,or UTRP

    l SFP0 orSFP1port ontheLMPT

    l FCconnector

    l SCconnector

    l LCconnector

    Externaltransmissionequipment

    Cablesinstalledbeforedelivery

    7.4Interconnection CableBetweenFE/GEElectricalPorts

    RJ45connector

    FE electricalport on theGTMU,WMPT,UMPT, orLMPT

    RJ45connector

    FE0 port onthe WMPT

    7.5Interconnection CableBetweenFE/GEOpticalPorts

    LCconnector

    FE opticalport on theGTMU,WMPT,UMPT, orLMPT

    LCconnector

    FE1 port onthe WMPT

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    32

  • Signal CablesThe following table describes signal cables.

    Table 2-23 Signal cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    8.4.5 EMUMonitoringSignalCable

    DB9 maleconnector

    RS485 porton the EMU

    RJ45connector

    MON1 porton the UPEUor UEIU

    8.2.19 BBUAlarmCable

    RJ45connector

    EXT-ALM0port on theUPEU orUEIU

    RJ45connector

    Externalalarm device

    Inter-BBUSignalCables

    DLCconnector

    DLCconnector

    CI port onthe UMPT

    HEI port onthe WBBPf

    HEI port onthe WBBPf

    8.4.11 GPSClockSignalCable

    SMA maleconnector

    GPS port onthe USCU,LMPT, orUMPT

    Type Nfemaleconnector

    GPS surgeprotector

    8.3.4MonitoringSignalCableBetweenCascadedFANs

    RJ45connector

    COM OUTport on theupper-levelfan assemblyNOTE

    The upper-level fanassemblycommunicates with theBBUdirectly.

    RJ45connector

    COM IN porton the lower-level fanassemblyNOTE

    The lower-level fanassemblycommunicates with theBBUthrough theupper-levelfanassembly.

    RETControlSignalCable

    SMA elbowmaleconnector

    ANT0 toANT5 portson theGATM

    SMA straightmaleconnector

    DC/OOKport on theDIN Bias-Tee

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    33

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position8.4.16GATMMonitoringSignalCable

    RJ45connector

    COM1 porton theGATM

    RJ45connector

    MON1 porton the UPEUor MON0port on theUEIU

    FMUC-GATMMonitoringSignalCable

    RJ45connector

    COM2 porton theGATM

    RJ45connector

    COM_INport on thelower-levelFAN

    8.4.15AdapterUsed forLocalMaintenance

    USBconnector

    USB(1) porton theUMPT in theBBU

    Networkconnector

    Networkcable

    8.4.14 CableBetweenTwoCombinedBaseStations

    DB15 maleconnector

    GCK port onthe UCIU inthe BBU

    MD36 orDB15 maleconnector

    DGLUb porton the DCTBin the 3012series basestation

    Cablesinstalledbeforedelivery

    8.2.15FMUC-BBUMonitoringSignalCable

    RJ45connector

    COM IN porton the FAN

    RJ45connector

    MON0 porton the UPEUor UEIU

    8.4.2 ELUSignalCable

    RJ45connector

    ELU RJ45connector

    SENSORport on theFAN

    NOTE

    a: The security of the USB port is ensured by encryption, and the USB port can be shut down usingcommands. The USB commission port is used for commissioning the base station rather than configuringand exporting information of the base station.

    CPRI Electrical Cables and CPRI Fiber Optic CablesThe following table describes the CPRI electrical cables and CPRI fiber optic cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    34

  • Table 2-24 CPRI electrical cables and CPRI fiber optic cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cablesinstalledbeforedelivery

    CPRIelectricalcables(1)

    SFP20 maleconnector

    CPRI portson theGTMU,WBBP,LBBP,UBRI, orUBBP

    SFP20 maleconnector

    CPRI0 orCPRI1 porton the RFU

    Cables to beinstalled onsite

    CPRI fiberoptic cable(optional)

    DLCconnector

    CPRI portson theGTMU,WBBP,LBBP,UBRI, orUBBP

    DLCconnector

    CPRI port onthe RRU

    NOTE

    (1) If boards and modules have been installed in a BTS3900L cabinet before delivery, CPRI electrical cablesare also installed in the cabinet before delivery. In this case, only the CPRI electrical cables between BTS3900cabinets must be installed onsite.

    RF CablesThe following table describes the RF cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    35

  • Table 2-25 RF cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    10.1 RFJumpers

    DIN elbowmaleconnector

    ANT_TX/RXA orANT_RXBport on anRFU

    DIN straightmaleconnector

    l Feeder oftheantennasystem(noGATMconfigured)

    l ANT porton theBias-Tee(GATMconfigured)

    Cablesinstalledbeforedelivery

    10.2 Inter-RFU RFSignalCable

    QMA elbowmaleconnector

    RX OUTport on theRFU

    QMA elbowmaleconnector

    RX IN porton anotherRFU

    2.2.2 BTS3900L (Ver.C) Cable ListThe BTS3900L cables are the PGND cables, power cables, transmission cables, CPRI cables,signal cables, and RF cables.

    PGND CablesThe following table describes the PGND cables.

    Table 2-26 PGND cablesCategory Cable One End The Other End

    Connector

    InstallationPosition

    Connector InstallationPosition

    Cables to beinstalledonsite

    PGND cablefor thecabinet

    OTterminal(M8)

    Groundterminal onthe cabinet

    OT terminal(M8)

    Externalground bar

    Cablesinstalledbeforedelivery

    PGND cablefor a module

    OTterminal(M4)

    Groundterminal on amodule

    OT terminal(M4)

    Groundterminal onthe cabinet

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    36

  • Power CablesThe following table describes the power cables.

    Table 2-27 Power cablesCategory Cable One End The Other End

    Connector

    InstallationPosition

    Connector InstallationPosition

    Cables to beinstalledonsite

    DCDU-11APowerCable

    OTterminal

    Global:l Black

    wire:RTN(+)terminalon theDCDU-11A

    l Bluewire:NEG(-)terminalon theDCDU-11A

    UK:l Blue

    wire:RTN(+)terminalon theDCDU-11A

    l Graywire:NEG(-)terminalon theDCDU-11A

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    6.4.4 RRUPowerCables(optional)

    Tool-lessfemaleconnector(pressfittype)

    One of theLOAD0 toLOAD5ports on theDCDU-11B

    Dependingon the RRUmodel

    Power porton an RRU

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    37

  • Category Cable One End The Other EndConnector

    InstallationPosition

    Connector InstallationPosition

    6.4.8 GATMPowerCable

    3V3connector

    -48V port onthe GATM

    Parallelterminal

    LOAD8 orLOAD9 porton theDCDU-11A

    DCDU-11BPowerCable(optional)

    OTterminal

    Global:l Black

    wire:RTN(+)terminalon theDCDU-11B

    l Bluewire:NEG(-)terminalon theDCDU-11B

    UK:l Blue

    wire:RTN(+)terminalon theDCDU-11B

    l Graywire:NEG(-)terminalon theDCDU-11B

    Dependingon theexternalpowerequipment

    Externalpowerequipment

    Cablesinstalledbeforedelivery

    6.4.3 RFUPowerCables

    3V3connector

    PWR port onthe RFU

    Parallelterminal

    One of theLOAD0 toLOAD5 portson theDCDU-11A

    FAN 03BPowerCable

    3V3connector

    -48V port onthe FAN 03B

    Parallelterminal

    LOAD6 porton theDCDU-11A

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    38

  • Category Cable One End The Other EndConnector

    InstallationPosition

    Connector InstallationPosition

    6.4.2 BBUPowerCable

    3V3connector

    -48V port onthe UPEU

    Parallelterminal

    LOAD7 orLOAD8 porton theDCDU-11A

    Transmission CablesThe following table shows the transmission cables.

    Table 2-28 Transmission cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position

    Cables to beinstalledonsite

    7.1 E1/T1Cable

    DB26 maleconnector

    E1/T1 porton theGTMU,WMPT,UMPT, orUTRP

    Dependingon theexternaltransmissionequipment

    Externaltransmissionequipment

    7.6 FE/GEEthernetCable

    RJ45connector

    FE or FE/GEelectricalport on theGTMU,WMPT,UMPT,LMPT, orUTRP

    RJ45connector

    Externaltransmissionequipment

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    39

  • Category Cable One End The Other EndConnector Installatio

    n PositionConnector Installatio

    n Position7.3 FE/GEFiber OpticCable

    LCconnector

    l FE or FE/GEopticalport ontheGTMU,WMPT,UMPT,or UTRP

    l SFP0 orSFP1port ontheLMPT

    l FCconnector

    l SCconnector

    l LCconnector

    Externaltransmissionequipment

    Cablesinstalledbeforedelivery

    7.4Interconnection CableBetweenFE/GEElectricalPorts

    RJ45connector

    FE electricalport on theGTMU,WMPT,UMPT, orLMPT

    RJ45connector

    FE0 port onthe WMPT

    7.5Interconnection CableBetweenFE/GEOpticalPorts

    LCconnector

    FE opticalport on theGTMU,WMPT,UMPT, orLMPT

    LCconnector

    FE1 port onthe WMPT

    Signal CablesThe following table describes signal cables.

    3900 Series Base StationCables 2 Cable List

    Issue Draft C (2014-03-26) Huawei Proprietary and ConfidentialCopyright Huawei Technologies Co., Ltd.

    40

  • Table 2-29 Signal cablesCategory Cable One End The Other End

    Connector Installation Position

    Connector Installation Position