3200 3200 Simplicity • Easy configuration with Quick Start codes • Parameter help scrolling text messages • Custom text messages • Customisable operator scroll list • Wizard for configuring advanced features Features • In built timer. • Programmer option • Master comms for multi-zone programming • CT input with load diagnostics
13
Embed
32003200 Simplicity Easy configuration with Quick Start codes Parameter help scrolling text messages Custom text messages Customisable operator scroll.
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
3200320032003200 Simplicity • Easy configuration with Quick Start codes
• Parameter help scrolling text messages
• Custom text messages
• Customisable operator scroll list
• Wizard for configuring advanced features
Features
• In built timer.
• Programmer option
• Master comms for multi-zone programming
• CT input with load diagnostics
• Recipe function: 5 x 38 parameters
3200320032003200FeaturesFeatures• Relay, logic or dc outputs
• Heat, cool, alarm outputs
• Dc control or retransmission
• 8 segment programmer
• Ammeter display
• RS232/RS485 3-wire Modbus
• Green or Silver coloured facia
32163216Size 48 x 48Size 48 x 48
32083208Size 48 x 96Size 48 x 96
32043204Size 96 x 96Size 96 x 96
AV
AIL
Oct
04
3200320032003200Programmer
RUN
Servo to SP or PV
RESET
Temp
Time
Programming = Rate, target, time X 4
End Type = Dwell
End Type = OFF
Holdback at start of dwell
END
Tip: Use Recipe function to store 5 programs with user defined names
32003200320032003216 Master 3216 Master programmerprogrammer• Broadcast address ‘0’ is used
Master digital comms
ApplicationsApplications• Multizone stress relieving - EHS, 1200 units pa
• Multizone ovens and furnaces
MODBUS
Slave controllersSlave controllers• Use Remote SP address ‘1A’
3200320032003200Hot runner ControllerWhat are hot runner controllers?What are hot runner controllers?
They are used on injection moulding machines to stop the plastic freezing as it runs into long narrow channels in the mould. These channels are kept warm by embedding cartridge heaters into the mould. The cartridges are hydroscopic (absorb water) and need to be slowly dried out to overcome earth leakage, shorted turns and overheating.
The hot runner (soft start) controller delivers a reduced power output until a set temperature or time is reached. The controller then reverts to normal PID control.
Phase angle thyristors are often used to control the heaters. The 3216 DC provides a very economical solution.
Soft start setpoint)
Soft start time
6
Quick Start ‘Set 1’3203200032032000
Type BType JType KType LType NType RType SType T
RTDpt100
Linear0-50mV0-20mA4-20mA
P
BJ
Input TypeThermocouple
KLNR
Custom /Type C
S
CT
4
M2
CF
0123456789
G
0 to 200.0 deg C0 to 400.0 deg C0 to 600 deg C
Fahrenheit32 to 212.0 deg F
Full PV rangedeg C full range
Centigrade0 to 100.0 deg C
Setpoint Limits
0 to 800 deg C
0 to 1200 deg C0 to 1400 deg C0 to 1600 deg C0 to 1800 deg C
0 to 1000 deg C
deg F full range
Tables A, B, C & DOutput 1
Tables A, B, C & DOutput 2
Tables A, C & DOutput AA
Table A - control
Heat (PID) HCool (PID) CHeat (On/Off) JCool (On/Off) K
• Calibration baths and Calibration baths and blocksblocks
• SterilizersSterilizers
• Vacuum formingVacuum forming
• Packaging (‘O’ Series)Packaging (‘O’ Series)
• ExtrusionExtrusion
• Injection moulding - hot runnersInjection moulding - hot runners• Baking ovensBaking ovens• Small Kilns and furnacesSmall Kilns and furnaces• Cold storesCold stores
- One item stocked. Recipes used to select Heat only, heat/cool or - One item stocked. Recipes used to select Heat only, heat/cool or indicator.indicator.