1 DSP based Digital Control Design for DC-DC Switch Mode Power Converter Shamim Choudhury Texas Instruments Inc.
24
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 3_1_Choudhury

1

DSP based Digital Control Design for DC-DC Switch Mode

Power Converter

Shamim ChoudhuryTexas Instruments Inc.

Page 2: 3_1_Choudhury

2

DC/DC Buck Converter

� Vin = 4V ~ 6V, � Vo = 1.6V, Io = 16A� L = 1uH, C = 1620uF, ESR = 0.004 ohm� PWM Freq = 250kHz, � Digital Control Loop Sampling Freq, fs = 250kHz,� Voltage Control Loop Bandwidth = 20kHz, � Phase Margin = 45 deg� Settling Time < 75uSec

C RLVin

VoIin

L

Io

Digital Control of DC/DC Converter

Page 3: 3_1_Choudhury

3

Digital Control of DC/DC Converter

Sample to PWM Update Delay Td = 0.5Ts(Computation Delay)

Sampling Scheme 1

Codeexecution

Sampling period (Ts)N N+1

Contextsave

Contextrestore

ExecuteController

Back-groundspare

Int Int

ISR

PWM/

t

PWM period n n+1

UpdatePWM

ADC conv time

ADC

Sampling Scheme 2Sample to PWM Update Delay Td = 2.0Ts

(Computation Delay)

PWM/ADC

Codeexecution

Sampling period (Ts)

ADC conv time

NN+1

tContextsave

Contextrestore

ExecuteController

Back-groundspare

Int IntISR

PWM period n n+1

UpdatePWM

UpdatePWM

UpdatePWM

Page 4: 3_1_Choudhury

4

CRL

=

d

Vo(s)PGd

Vo(n)U(n) Gc(z)

PWM A/D

Vref TMS320F2810

+E(n)

Vin

VoIin

L Vos

Kd

Digital Control of DC/DC ConverterControl Design by Emulation

31)(,17

)()(

maxmax

maxmax

QinnVforV

KKVFFFFFFh

KVnVKVnV

oo

ddo

doodoo

=⇒=⇒

=⇒=

=> Kd=0.5

Vo(n)

0

2V

00000000

7FFFFFFF

Vo

Output Voltage Sensing Gain

Page 5: 3_1_Choudhury

5

Digital Control of DC/DC Converter

1.62x10-5 s + 2.5Gp1(s) = ---------------------------------------

1.685x10-9 s2 + 1.648x10-5 s + 1

Vin=5.0, RL=0.1, Kd=0.5,L=1uH, C=1620uF, Rc=0.004 ohm,

d

U(n)

Vo

Kd

Gc(z)

Vref

+

Vo(n)

E(n)

Gp(s)

Gc(s) = ?, Gc(z) = ?

Ignore Sample & Hold (S&H) Effect,PWM Modulator Gain Fm = 1,Continuous Plant Gp1(s) = Kd.Fm.Gp(s),

Fm

Control Design by Emulation

Page 6: 3_1_Choudhury

6

Continuous System Bode Plot

14.3 s^2 + 651400 s + 7.2e009Gc1(s) = ------------------------------------------

s^2 + 125600 s

Digital Control of DC/DC Converter

Use Matlab SISOTOOL for the plant Gp1(s) and design the continuous controller Gc1(s)

(Matlab)s-plane root locus

(Matlab)

Settling Time(1%)< 45uS

BW = 25kHz, PM = 71 deg

Page 7: 3_1_Choudhury

7

12.34 z^2 - 22.53 z + 10.28Gc1(z) = -------------------------------------------

z^2 - 1.605 z + 0.6051

[pole-zero matched, Ts = 4uSec]

Digital Control of DC/DC ConverterCompute Equivalent Discrete Controller Gc(z)

1. Discrete Equivalents via Numerical Integration1a. Forward rule, s= (z-1)/Ts2a. Backward rule, s = (z-1)/zTs3a. Trapezoidal/Tustin/Bilinear, s = 2(z-1)/Ts(z+1)

2. Pole-Zero Matching Equivalents, z = esTs

3. Hold Equivalents : zero-order-hold (ZOH), first-order-hold (FOH)

In Matlab, Gc_z = c2d(Gc_s, Ts, 'matched')

12.49 z^2 - 22.81 z + 10.41Gc1(z) = ------------------------------------

z^2 - 1.598 z + 0.5985[Tustin, Ts = 4uSec]

In Matlab, Gc_z = c2d(Gc_s, Ts, ‘tustin')

Page 8: 3_1_Choudhury

8

Digital Control of DC/DC ConverterDiscrete System Bode Plot, Pole-Zero Matched Controller,

Discrete System Bode Plot, Tustin Controller,

Control Design by Emulation

(Matlab)

(Matlab)

Gp1(z)*Gc1(z)

BW = 25.2kHz, PM = 53.1 deg, GM = 11.3dB

BW = 25.4kHz, PM = 53.6 deg, GM = 11.2dB

Gp1(z)*Gc1(z)

Transient Response (Fpwm = 250KHz), Pole-Zero Matched Controller

Gp1(z)*Gc1(z)

Page 9: 3_1_Choudhury

9

Direct Digital ControlDigital Control of DC/DC Converter

d

Vin

U(n)

Vo

Kd

Iin

Gc(z)

D/A(ZOH)

Vref TMS320F2810

L CRL

+

Vo(n)

E(n)∧

=

d

Vo(s)PGHc

Comp Delay ModelHc = e-sTd ,Td = Comp Time Delay

Ts

Page 10: 3_1_Choudhury

10

Direct Digital Control of DC/DC Converter

fs = 250kHz,

f = 125kHz, additional

phase lag of 90°

f = 7.25kHz,additional

phase lag of 5.2°

PM = 33.18 deg

PM = 28 deg

Effect of Sampling & Hold

ZOH = -ωTs/2 = -180f/fs

Ts

Time Delay Ts/2

Page 11: 3_1_Choudhury

11

Direct Digital Control

1.62x10-5 s + 2.5Kd.Gp(s) = -------------------------------------

1.685x10-9 s2 + 1.648x10-5 s + 1

Vin=5.0, RL=0.1, Kd=0.5L=1uH, C=1620uF, Rc=0.004 ohm

ZOH(s) = (1 – e-sTs )/s

Discrete Plant Model,Gp(z) = Z{ZOH(s).Kd.Gp(s).Hc}

d

U(n)

Vo

Kd

Gc(z)

ZOH

Vref

+

Vo(n)E(n)

Gp(s)

Ts

Gp(z)

Hc

Digital Control of DC/DC Converter

Hc = e-sTd

Gp1(z) = (0.0494z - 0.0261)/(z2 - 1.952 z + 0.962), [Td=0, Hc = 1]

Page 12: 3_1_Choudhury

12

Direct Digital Control of DC/DC Converter

Discrete System Bode Plot,2 Pole 2 Zero Type Controller,

Use Matlab SISOTOOL for Gp1(z), and design Gc2(z)

Gp1(z)*Gc2(z)

14.87 z^2 - 26.91 z + 12.16Gc2(z) = -------------------------------------

z^2 - 1.473 z + 0.4731

BW = 27.9kHz, PM = 61.6 deg, GM = 9dB

(Td=0)

Settling Time(1%) < 56 uSec

Gp1(z)*Gc2(z)

Page 13: 3_1_Choudhury

13

Direct Digital Control of DC/DC ConverterEffect of Computation Delay

Plant with computation delay [Td = 0.5Ts],Gp2(z) = (0.022z^2+0.017z - 0.158)/z(z^2 - 1.952 z + 0.962), Controller with no delay compensation,Gc2(z)=(14.87 z^2 - 26.91 z + 12.16)/(z^2 - 1.473 z + 0.4731 )

BW = 26.9kHz, PM = 41 deg, GM = 7.46dB

Hc = -ωTd= -360fTd

Loss of PM from(Gp1*Gc2) to (Gp2*Gc2)

= 61.6-41= 20.6 deg

Hc = 360(26900)(2uS)= 19.37 deg

Bode Plot (Matlab)

Gp2(z)*Gc2(z)

Phase Lag,

Page 14: 3_1_Choudhury

14

Direct Digital Control of DC/DC ConverterBode Plot (Measured)

BW = 22.45kHz, PM = 40 deg, GM = 10.7dB

Gp2(z)*Gc2(z)

Page 15: 3_1_Choudhury

15

Transient Response (Fpwm = 250KHz)Direct Digital Control of DC/DC Converter

Gp2(z)*Gc2(z)

Page 16: 3_1_Choudhury

16

Plant with increased computation delay [Td = 2.0Ts],Gp3(z) = (0.022z^2+0.017z - 0.159)/z^2(z^2 - 1.954 z + 0.963),

Direct Digital Control of DC/DC ConverterEffect of Computation Delay

Controller with no delay compensation,Gc2(z)=(14.87 z^2 - 26.91 z + 12.16)/(z^2 - 1.473 z + 0.4731 )

Hc = -ωTd = -360fTd

Loss of PM from (Gp1*Gc2) to Gp3*Gc2

= 61.6 – (-19) = 80.6 deg

Hc = 360(27900)2(4uS)= 80.35 deg

Bode Plot (Matlab)

Gp3(z)*Gc2(z)2 Pole 2 Zero Type Controller

BW = 27.9kHz, PM = -19.0 deg, GM = -2.22dB,Unstable Loop.

Phase Lag,

Page 17: 3_1_Choudhury

17

Direct Digital Control of DC/DC Converter

Unstable System, Uncompensated for Computation Delay Transient Response (Fpwm = 250KHz)

Gp3(z)*Gc2(z)

Page 18: 3_1_Choudhury

18

Direct Digital Control of DC/DC ConverterRedesigned Controller with Delay Compensation

14.4 z^3 – 31.1 z^2 + 20.1 z – 3.376Gc3(z)=U/E= -------------------------------------------------

z^3 - 1.235 z^2 + 0.2362 z - 0.00115

Bode plot (Matlab)

BW = 16.1kHz, PM = 46.4 deg, GM = 3.77dB

Gp3(z)*Gc3(z)

3 Pole 3 Zero Type Controller

Page 19: 3_1_Choudhury

19

Direct Digital Control of DC/DC ConverterRedesigned Controller with Delay Compensation

Bode plot (Measured)

Gp3(z)*Gc3(z)

BW = 15.28kHz, PM = 41.76 deg, GM = 3.4dB

Page 20: 3_1_Choudhury

20

Direct Digital Control of DC/DC Converter

System Compensated for Computation Delay Transient Response (Fpwm = 250KHz)

Gp3(z)*Gc3(z)

Page 21: 3_1_Choudhury

21

Voltage Mode Control: Computation Flow, Benchmark Results

9.962625941300500

21.52655941600250

Number of LoopsCycles/loopAvailableCyclesOverheadCycles

Sampling Freq(KHz)

TMS320C28x=150MHz (32-bit implementation)

Digital Control of DC/DC Converter

( ) ( ) ( ) ( ) ( )nEbnEbnEbnUanUanU ×+−×+−×+−×+−×= 011221122)(

14.87 z2 – 26.91 z + 12.16 14.87 – 26.91 z -1 + 12.16 z -2

Gc(z) = U/E = ------------------------------------ = -------------------------------------------z2 - 1.473 z + 0.4731 1 – 1.473 z -1 + 0.4731 z -2

PWMPRDnUsatDprdnUnUsat

×=≤≤=

)(max)(min)(

Gc(z)Vref

VoDprd

Page 22: 3_1_Choudhury

22

Hc = -ωTd = -360fTd = -360f(kTs) = -360k /(fs/f), [ k = Td /Ts]

Digital Control of DC/DC ConverterSampling Frequency (fs) Selection

0

20

40

60

80

100

120

0 0.25 0.5 0.75 1 1.25 1.5 1.75 2K

Phas

e La

g (H

c)

fs/fc=5

fs/fc=10

fs/fc=12.5

fs/fc=20

fc = crossover frequency

Computation Delay per unit Ts, (Td /Ts)

Page 23: 3_1_Choudhury

23

Digital Control of DC/DC ConverterSampling Frequency (fs) Selection

fs = 12.5*fc

fs = 20*fc

fs = 30*fc

Page 24: 3_1_Choudhury

24

PWM Resolution & Limit CycleDSP Clock Freq = 150MHz, fpwm = 250kHz, PWM Duty Ratio Resolution

= 1/(150M/250k) = 1/600 = 0.167%

ADC resolution = 10bits, Vo = 2V (max),Vo Sensing Resolution ∆Vad = 2V/1024 = 1.95mV

Sense circuit

∆Vpwm Vo

PWM

Vin

A/D

∆VadFor Vin = 5V, Applied Volt Resolution ∆Vpwm1 = 5V/600 = 8.33mV,For Vin = 2V, Applied Volt Resolution ∆Vpwm2 = 2V/600 = 3.33mV,

Digital Control of DC/DC Converter

∆Vpwm1 > ∆Vad,=> Limit Cycle

∆Vpwm2 ≈ ∆Vad,=> Negligible Limit Cyc.

Vin = 2VVo = 0.8V