2.4-1 VZ100 VZ300 VZ300 VZ500 VZ500 M5 N.C. P→A: A→R: M5 3.6 (196.3) 9.0 (490.75) 4.5 (245.38) N.C. N.O. , 9.0 (490.75) Body Ported Base Mounted Port Size Effective Area mm 2 (Nl/min ) Actuation Voltage Series Electrical Entry Option/light and surge voltage suppressor Manual Override 1 8 1 8 1 8 1 4 (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC (Option) 24V AC 50/60Hz 48V AC 50/60Hz 110V AC 50/60Hz 220V AC 50/60Hz 6V DC 12V DC 48V DC Indicator light and surge voltage suppressor Non-locking push style Non-locking push style Locking slotted style Locking knob style DIN Terminal (D) 0.6 (33.37) 0.9 (49.08) N.O. R→A: 0.6 (33.37) A→P: 0.6 (33.37) 3 Port Solenoid Valve Rubber Seal VZ100/300/500 Solenoid Valve Variations
44
Embed
3 Port Solenoid Valve Rubber Seal VZ100/300/500€¦ · VZ110 (N.C.) JIS symbol De-energized JIS symbol De-energized No. Description Solenoid Ass’y Solenoid Ass’y O ring Part
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
2.4-1
VZ100
VZ300
VZ300
VZ500
VZ500
M5
N.C.P→A:
A→R:
M5 3.6
(196.3)
9.0
(490.75)
4.5
(245.38)
N.C.
N.O.
, 9.0
(490.75)
Bo
dy
Po
rted
Bas
e M
ou
nte
d
Port Size Effective Area mm2
(Nl/min )
Actuation VoltageSeries ElectricalEntry
Option/light andsurge voltagesuppressor
Manual Override
1 8
1 8
1 8 1 4
(Standard)100V AC 50/60Hz200V AC 50/60Hz24V DC
(Option)24V AC 50/60Hz48V AC 50/60Hz110V AC 50/60Hz220V AC 50/60Hz6V DC12V DC48V DC
Indicator light and surge voltage suppressor
Non-locking push style
Non-locking push style
Locking slotted style
Lockingknob style
DINTerminal (D)
0.6(33.37)0.9(49.08)
N.O.R→A: 0.6 (33.37)
A→P: 0.6 (33.37)
3 Port Solenoid ValveRubber Seal
VZ100/300/500Solenoid Valve Variations
2.4-2
VZ100/300/500
Manifold Variations
Series VZ100
Series VZ300
Series VZ500
A port sizeWith one-touch fitting
Applicable tube O.D.Valve SeriesA port position
P/R port size
M5 X 0.8 — — — —
— — — —
ø8ø6ø4
VZ100 Top
M5 1 8
Bo
dy
Po
rted
Bas
e M
ou
nte
d
— — — —
— (1) — — —
— — — —
VZ300 Top
VZ500 Top
1 8
1 8
1 8
1 4
— — —
— —(1) — —
—VZ300
Bottom
Side
VZ500 Bottom
1 8
1 8
— — — — 1 4
— — Side 1 4
Note 1) Internal pilot
2.4-3
Common Exhaust for Main Valve & Pilot Valve
Be sure to read before handling. Refer to p.0-33 to 0-36 for Safety Instructions and common precautions.
Precautions
Warning
Manual override is capable in 2 ways, non-locking push style and locking style. (Locking style is for VZ300, VZ500 only)
The non-locking push style must be pressed in the direction of the arrow. The locking style must be turned in the direction of the arrow.
When operating the locking style manually, apply torque of 0.2Nm or less.
During manual operation, the equipment that is connected will oper-ate. Therefore, make sure there are no hazardous conditions before operation.
Manual Override
–: Non-locking push style
C: Locking knob style
B: Locking slotted style
DIN terminal
AC
DC
With light (AC)
With light (DC)
In the case of DC wiring, connect terminal No.1 of the connector to the positive [+] side, and terminal No. 2 to the negative [–] side.(Refer to the marks on the terminal board.)
AC DC
VZ324M, VZ52
4MExhaust air from the pilot valve will flow to the main valve exhaust port.For use in an environment in which exhaust from the pilot valve is undesir-able.For use when the intrusion of dust from the surroundings must be prevented. Also, make sure the piping will not restrict the flow from the exhaust port.
∗ Marking
2.4-4
How to Use DIN Connector
Connection1) Loosen set screw and pull out connector from the terminal block of solenoid.2) Pull out screw and insert a screwdriver into the slit area near the bottom of terminal block to separate block and housing.3) Loosen the terminal screw of the terminal block, place bare end of lead wire into terminal in accordance with the wiring method, and affix it securely with the terminal screw.4) Tighten ground nut to secure the wire.
Change of electrical entry (orientation)After separating the terminal block and housing, mount the housing at any posi-tion (total 4 directions, per 90 degrees), therefore changing electrical entry.∗In the case of indicator light, avoid damaging the light with lead wire.
PrecautionsPlug the connector in or out vertically, never at an angle.
Applicable cableCable O.D. ø3.5 to ø7(Reference) 0.5mm2 2-core and 3-core wires equivalent to JISC3306.
VZ100/300/500
Connector Part No.Without light K31
With lightRated voltage Symbol
100V200V
240V6VD
12VD24VD48VD
100V AC200V AC
240V AC6V DC
12V DC24V DC48V DC
Part No.
110V110V AC K33220V220V AC
K32
Connector with Light CircuitAC
circuit
NL: Neon light R: Resistor
DCcircuit
D : Protection diodeLED : Light emitting diodeR : Resistor
How to Order Solenoid Assembly
CDXT170Indicator light and surge suppressor– None
Z∗ Indicator light and surge suppressor
S Surge voltage suppressor
∗Indicator light is not available for grommet style.
Electrical entryDIN
terminalD With connector
Without connectorDO
Coil rated voltage1234569
100V AC 50/60Hz200V AC 50/60Hz200V AC 50/60Hz220V AC 50/60Hz
24V DC12V DCOthers
Applicable model
C
AVZ300VZ500
Series
VZ110
E VZ120
5 L Q
Contact SMC for other voltages (9)
OrderMade
Flow rateRefer to the p.0-36 for flow rate.
2.4-5
3 Port Body PortedRubber Seal
Series VZ100How to Order
Body Ported VZ1 0
Actuation
1
Normally closed
2
Normally open
D: With connector
DO: Without connector
DIN terminal
Indicator light and surge voltage suppressor
Electrical entry
– None
Port size
Z∗ S
With indicator light and surge voltage suppressorWith surge voltage suppressor
F: With foot style bracket
Option
M5 QActu
ation
Rated
volta
ge
Electri
cal e
ntry
Indic
ator
light
and
surg
e vo
ltage
supp
ress
or
Option
Port s
ize
Note) Bracket is not assembled.
Rated voltage1234569
100V AC 50/60Hz200V AC 50/60Hz110V AC 50/60Hz220V AC 50/60Hz
24V DC12V DCOthers
Regarding VZ120, R port is a supply port.
1Ord
ering
sour
ce a
rea
code
E 5 D
M5 M5
Code
EN
areasJapan,AsiaAustralia,England
EuropeNorth America
Ordering source area code
-
Protective classclass I (Mark: )
∗ DOZ is not available.
Contact SMC for other voltages (9)
OrderMade
Operating Pressure Range and Effective Area
2.4-6
Low Power Consumption: 1.8WDC
Applicable for Vacuum Use –100kPa
Specifications
VZ100
Fluid
Ambient and fluid temperature (°C)Response time (ms)(1)
Non-locking push styleEffective area See belowMax. operating frequency (Hz) 15
Non-lubeFree
300/50Dust proof
Note 1) According to dynamic performance test of JIS B8374-1981.(Coil temperature 20°C, rated voltage, without surge voltage suppressor)Note 2) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Vibration resistance: No malfunction from test with 45 to 1000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.)
Note 1) If there are more than 10 stations, exhaust from both sides of manifold.Note 2) Value at manifold base mountedNote 3) Not able to use VZ120 and VZ110 on the same manifold base.Note 4) In case of VZ120, supply air to R port and exhaust from P port.
2.4-8
Series VZ100
Manifold
Manifold Specifications
How to Order Manifold Base
Combinations of solenoid valve, gasket and manifold base
To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base. (Sample)VV3Z1-01-031-Q ·········· 1 pc. (Manifold base)VZ110-5D-M5-Q ·········· 2 pcs. (Valve)DXT170-25-1A-Q ········· 1 pc. (Blank plate assembly)
Option
Blank plate assemblyDXT170-25-1A
Individual EXH spacer assembly
DXT170-48-1A
Individual SUP spacer assembly
DXT170-44-1A
Applicable baseVV3Z1-01-1VV4Z1-20-1
Applicable baseVV3Z1-01-1VV4Z1-20-1
Applicable baseVV3Z1-01-1VV4Z1-20-1Manifold base Manifold base
Manifold base
Applicable baseVV3Z1-01-1VV4Z1-20-1 Manifold base
…… 2 stations
20 stations
02
20
Stations
∗ The bracket is not assembled.
F: With foot bracket
OptionVV3Z1 01 1 Q05E
Ordering source area code
Rc (PT)G (PF)NPT
NPTF
00F00N00T
P, R port thread
Code
EN
areasJapan,AsiaAustralia,England
EuropeNorth America
-
-
2.4-9
VZ100
01 Type Manifold Base: Top Ported
L plug connector (L) M plug connector (M) DIN terminal (D)
: with indicator light and surge voltage suppressor
How to Order
Note) If there are more than 10 stations, exhaust from both sides manifold.
It is not able to use VZ110 and VZ120 on the same manifold base.
Note: This valve series is now only available with DIN connector.
∗ The bracket is not assembled.
F: With foot bracket
Option
Q
Rc (PT)G (PF)NPT
NPTF
00F00N00T
P, R port thread
…… 2 stations
20 stations
02
20
Stations
VV4Z1 20 105E
Code
EN
areasJapan,AsiaAustralia,England
EuropeNorth America
Ordering source area code
-
-
2.4-10
VZ100
20 Type Manifold Base: Top Ported
L plug connector (L) M plug connector (M) DIN terminal (D)
: with indicator light and surge voltage suppressor
How to Order
Note) If there are more than 10 stations, supply air to SUP port on both sides of the manifold and exhaust from EXH port on both sides of the manifold.
It is not able to use VZ110 and VZ120 on the same manifold base.
Effective area See belowMax. operating frequency (Hz) 10
Non-lubePilot exhaust Individual pilot exhaust, Common exhaust (pilot and main valve)
Free300/50
Dust proof
Internal pilot
According to dynamic performance test of JIS B8374-1981.( Coil temperature 20˚C, rated voltage, without surge voltage suppressor)When operating the locking style manually, apply torque of 0.2Nm or less.Impact resistance:
Vibration resistance:
No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.)No malfunction from test with 8.3 to 2000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.)
Note 1)Note 2) Note 3)
Low Power Consumption: 1.8WDC
Applicable for Vacuum Use–100kPa VZ300R: External pilot style
Exhaust measures for the pilot valve are unneces-sary.VZ300M: Central exhaust styleIt is not necessary to take exhaust measures for the pilot valve for environmental protection.
Can also be used as a selector valve or a divider valve.VZ300R: External pilot styleCan be used for universal porting.
Specifications
Solenoid Specifications
VZ300
Effective Area and Weight
Option
Series VZ300/Body Ported
Series VZ300/Base Mounted
Valve
Body ported style
Base mounted style (with sub-plate)
VZ312VZ322VZ314VZ324
Actuation
N.C.N.O.N.C.N.O.
Port size
M5 X 0.8
1 8
Effective area (mm2) (Nl/min)
3.6 (196.3)
4.5 (245.38)
Weight (g)
75
105(without sub-plate: 75)
Description Foot bracket
Part No.DXT170-34-1B
NoteWith screw (for VZ32)
Replacement PartsComponent Parts
2.4-13
External Pilot
VZ300
Specifications
This obtains external pressure for the pilot valve separately from the main valve pressure. It can be operated with a low pressure line with a vacuum (to –100kPa) or below 0.15MPa.
Applicable model
Operating pressure rangeMPa
Base mounted style(VZ314R, VZ324R)Main pressure
External pilot pressure–100kPa to 0.7
0.15 to 0.7
Note 1) Refer to the p.2.4-16 for manifold base.
Note 2) In the case of the body ported style, the pilot style (VZ32R) is used exclu-sively on a manifold. An external pilot style that can be used individually is available as a Made to Order.
JIS symbol
VZ31R
VZ32R
Construction
No. Description
ResinAluminium die cast
MaterialAluminium die cast
Resin
NotePlatinum silver
BlackBlack
Piston plateBody
End coverPistonSpool valve ass’y
Stainless steelSpool springt
r
e
w
q
y
No. DescriptionSub-plateSolenoid ass’yO-ring
MaterialAluminium die cast
Epoxy, stainless steelNBR
Part No.DXT200-13-1PDXT170-C-13 X 11 X 1
Note
Common with VZ100
u
i
o
N.C. N.O.
VZ300R
2.4-14
VZ300
Body Ported
Grommet (G), (H)VZ32-G
H-M5
M plug connector (M)VZ32-M-M5
DIN terminal (D)VZ32-D-M5-Q
: with indicator light and surge voltage suppressor
L plug connector (L)VZ32-L-M5
Note: This valve series is now only available with DIN connector.
2.4-15
VZ300
Base Mounted
M plug connector (M)VZ34-M-01
DIN terminal (D)VZ34-D-01-Q
: with indicator light and surge voltage suppressor
L plug connector (L)VZ34-L-01
Grommet (G), (H)VZ34-G
H-01
Note: This valve series is now only available with DIN connector.
P(SUP)/R(EXH) style Common SUP/Common EXHStations 2 to 20A portpiping
Position
External pilotInternal pilot
DirectionP, R port
X port (1)
A port
Internal pilotExternal pilot
Body portedVZ32/VZ32R
Base mountedVZ34/VZ34R
ValveTop Bottom
BaseSide
Port size
M5 X 0.8
M5: 3.3(176.67) : 4.8(265.01)
C4, C6: 3.8(206.12)
M5 X 0.8, , C4(ø4One touchfitting), C6(ø6One touchfitting)
M5 X 0.8
p.2.4-18, 24-19
: 4.7(255.19)M5: 3.8(206.12)
p.2.4-24, 24-25
M5 X 0.8
M5 X 0.8
3.4 (0.19) –
–
p.2.4-17p.2.4-23
Valve effectivearea (mm2)(Nl/min)
Page on How to Order
M5 X 0.8
p.2.4-20 to 2.4-22p.2.4-26 to 2.4-28
1 81 8
1 8
1 8
1 81 8
1 8
20- 140R- 240- 2
40R- 140- 1
Note 1) Only for external pilotNote 2) Value at manifold base mounted
(2)
Series VZ300
Manifold
Manifold Specifications
Combinations of solenoid valve, manifold gasket and manifold base
Option
Base mounted (VZ34)
Blank Plate Assembly
DXT200-8-1A
Applicable baseVV3Z3-20-1VV3Z3-21R-1Manifold base
How to Order Manifold Base
To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base.(Sample)VV3Z3-20-031-Q ···1 pc. (Manifold base) VZ312-5D-M5-Q ···2 pcs. (Valve) DXT170-25-1A ······1 pc. (Blank plate ass’y)
Body ported (VZ32)
Model No.: DXT170-25-1A
Applicable baseVV3Z3-20-1Manifold base
Applicable baseVV3Z3-21R-1Manifold base
Manifold base
Applicable baseSub-plate
VV3Z3-40-2VV3Z3-40-1VV3Z3-40R-2VV3Z3-40R-1
Manifold base
2.4-17
VZ300
For Internal Pilot20 Type Manifold: Top Ported
Grommet (G), (H)
L plug connector (L) M plug connector (M) DIN terminal (D)
: with indicator light and surge voltage suppressor
How to Order
Note) If > 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold.
…… 2 stations
20 stations
02
20
Stations
VV3Z3 20 1 Q05
Note) If more than 6 stations, supply air to P port on both sides of the manifold and exhaust from R port on both sides of the manifold.
Note: This valve series is now only available with DIN connector.
Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the mani-fold.
Applicable solenoid valve VZ314R--Q VZ324R--Q
Applicable blank plate assembly DXT200-8-1A
Q
Rc (PT)G (PF)NPT
NPTF
F-
NT
P, R port thread
E
Note) If > 9 stations, supply and exhaust air through P port or R port on both sides of the manifold.
2 stations
20 stations
02
20
Stations
A port size
VV3Z3 40R 105 C6
C4 ø4 One-touch fittingC6 ø6 One-touch fitting
Code
EN
areasJapan,AsiaAustralia,England
EuropeNorth America
Ordering source area code
-
Rated voltage12
3 4
5 6 9
100V AC 50/60Hz200V AC 50/60Hz110V AC 50/60Hz 220V AC 50/60Hz
24V DC12V DCOthers
Body option–: Non-locking push style
B: Locking slotted style
C: Locking knob style
Manual override
01: With sub-plate
Port size1 8 02:
With sub-plate1 4 –: Without sub-plate
1 8
Body Ported VZ5Actu
ation
Rated
volta
ge
Electri
cal e
ntry
Indic
ator
light
and
surg
e
volta
ge su
ppre
ssor
Option
Base Mounted VZ5
Man
ual o
verri
de
Port s
ize
Body o
ption
1 2 5 D 01
1 4 5 D
–: Individual pilot exhaust style
M: Common exhaust (pilot and main valve) style
R: External pilot style(1)
D:With connector
DO: Without connector
DIN terminal
∗Not available for DOZ
Indicator light and surge voltage suppressor
Electrical entry
– None Z∗
SIndicator light and surge voltage suppressor
Surge voltage suppressor
Actuation
1
Normally closed
2
Normally open
Port sizeF: With foot bracket
Option
Note) ·
·
The bracket is not assembled.Except for external pilot.
Note 1) VZ52R is only for manifold.
01Ordering source area code
E EuropeN North America
-
CodeJapan, Asia
Australia, England
areas
Q
Q
Contact SMC for other voltages (9)
OrderMade
Rc (PT)NPT
G (PF)NPTF
N
F
-
T
Thread
2.4-29
3 Port Body Ported, Base MountedRubber Seal
Series VZ500How to Order
2.4-30
Low Power Consumption: 1.8WDC
Applicable for Vacuum Use –100kPa500R: External pilot style
Exhaust measures for the pilot valve are unnecessary500M: Central exhaust styleIt is not necessary to take exhaust measures for the pilot valve for environmental protection.
Can also be used as a selector valve of a divider valve.500R: External pilot styleCan be used for universal porting.
Individual pilot exhaust, Common exhaust (pilot and main valve)Non-lube
Free300/50
Dust proof
Ambient and fluid temperature (˚C)
Internal pilot
Max. operating frequency (Hz)See belowEffective area
Manual override (2)
Pilot exhaustLubricationMounting positionImpact/vibration resistance (m/s2) (3)
Protection structure
Note 1) According to dynamic performance test of JIS B8374-1981. (Coil temperature 20˚C, rated voltage, without surge voltage suppressor)Note 2) When operating the locking style manually, apply torque of 0.2Nm or less.Note 3) Impact resistance: No malfunction from test using drop impact tester, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.) Vibration resistance: No malfunction from test with 8.3 to 2000Hz 1 sweep, to axis and right angle directions of main valve and armature, each one time when energized and de-energized. (Value in the initial stage.)
Valve Actuation Port sizeEffective area (mm2) (Nl/min)
Weight (g)
Body Ported
Base Mounted(With sub-plate)
VZ512
VZ514VZ522
VZ524
N.C.
N.C.N.O.
N.O.160
(Without sub-plate 110)
9.0 (490.75)
9.0 (490.75)
1101 8
, 1 8 1 4
DescriptionFoot bracket
Part No.DXT201-19-1A
NoteWith screw (for VZ52)
Solenoid Specifications
2.4-31
VZ500
External Pilot: VZ500R
Specifications
This obtains external pressure for the pilot valve separarely from the main valve pressure. It can be operated with a low pressure line with a vacuum (to –100kPa) or below 0.15MPa.
Note 1) Refer to the p.2.4-34 for manifold base.
Note 2) In the case of the body ported style, the pilot style (VZ32R) is used exclusively on a manifold. An external pilot style that can be used individually is available as an Order Made specification.
JIS symbol
VZ51R
VZ52R
Component Parts
Construction
Replacement Parts
N.C. N.O.
Applicable modelOperating pressure range
MPaMain pressure
External pilot pressure
Base mounted (VZ314R, VZ324R)–100kPa to 0.7
0.15 to 0.7
No. Description
ResinAluminium die cast
MaterialAluminium die cast
Note
Piston plateBody
End coverResinPiston
BlackBlack
Platinum silver
Spool valve ass’yStainless steelSpool spring
q
w
e
r
t
y
No. Description
DXT201-2-2PEpoxy, stainless steel
Part No.DXT201-2-1P
Material
Aluminium die castSub-plate
Solenoid ass'y13 X 11 X 1
Note
Common with VZ100NBRO ring
1 81 4
u
i
o
2.4-32
VZ500
Body Ported
Grommet (G), (H)VZ52-G
H-01
M plug connector (M)VZ52-M-01
DIN terminal (D)VZ52-D-01-Q
: with indicator light and surge voltage suppressor
L plug connector (L)VZ52-L-01
Note: This valve series is now only available with DIN connector.
2.4-33
VZ500
Base Mounted
: with indicator light and surge voltage suppressor
M plug connector (M)VZ54-M- 01
02
DIN terminal (D)VZ54-D- -Q01
02
L plug connector (L)VZ54-L- 01
02
0102
GH
Grommet (G), (H)VZ54- -
Note: This valve series is now only available with DIN connector.
2.4-34
Model
Manifold Single base/B mount–
P(SUP)/R(EXH) style Common SUP/Common EXHStations 2 to 20 stationsA portpiping
Position
External pilotInternal pilot
DirectionP/R port
X port (1)
A port
Internal pilotExternal pilot
Body portedVZ52/VZ52R
Base mountedVZ54/VZ54R
ValveTop
Port size
: 9.2(0.51)C6: 8.8(0.49)C8: 10(0.56)
–
10.6(0.59) –
–
p.2.4-35
–
Valveeffectivearea mm2(Cv) (2)
Page on Howto Order
p.2.4-36p.2.4-41
p.2.4-37
10.2(0.57)
–
p.2.4-38
10.2(0.57)
p.2.4-42p.2.4-39, 2.4-40p.2.4-43, 2.4-44
1 8
1 8
ValveTop 1 4
BaseBottom
1 8
M5
BaseBottom
1 4
1 8 1 8 1 8 1 8
– M5 M5
BaseSide
1 4
C6
1 8
20- 121R- 121- 1
–40- 2
41R- 241- 2
41R- 141- 1
Note 1) Only for external pilotNote 2) Value at manifold base mounted
ø6 One-touch fitting
C8ø8 One-touchfitting
Series VZ500Manifold
Manifold Specifications
Combinations of solenoid valve, manifold gasket and manifold base
Option
Base mounted (VZ54)
Blank plate Assembly
DXT201-15-1A
How to Order Manifold Base
To order valves and blank plate assembly mounted onto the manifold, list valves and blank plate assembly with manifold base.(Sample)VV3Z5-20-031-Q ···1 pc. (Manifold base) VZ512-5D-01-Q ····2 pcs. (Valve) DXT201-15-1A ······1 pc. (Blank plate ass’y)