3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution
9

3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

Dec 31, 2015

Download

Documents

3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution. 3-dB Power Divider. S 41 = -33.99 dB S 32 = -31.50 dB. S 11 = -31.69 dB S 44 = -34.24 dB. S 42 = -3.168 dB (48.21%) S 43 = -3.052 dB (49.53%). S 21 = -3.085 dB (49.15%) S 31 = -3.168 dB (48.22%). - PowerPoint PPT Presentation
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

3-dB Power Divider and Hybrids for 8-Pack Phase II Power

Distribution

Page 2: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

3-dB Power Divider

S11 = -31.69 dB

S44 = -34.24 dB

S41 = -33.99 dB

S32 = -31.50 dB

Page 3: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S21 = -3.085 dB (49.15%)

S31 = -3.168 dB (48.22%)

S42 = -3.168 dB (48.21%)

S43 = -3.052 dB (49.53%)

~2.63% power missing.

Wrap-around: ~1.0% loss

~1.63% loss in part

~2.26% power missing.

~2% more power to downstream port (2), which will incur more transmission loss.

Page 4: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

Magic-H Hybrids

S11 = -35.36 dBS22 = -46.16 dBS33 = -37.50 dBS44 = -31.76 dB

S11 = -36.18 dBS22 = -33.71 dBS33 = -43.08 dBS44 = -31.63 dB

Page 5: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S41 = -40.06 dBS32 = -33.71 dB

S41 = -39.76 dBS32 = -32.94 dB

Page 6: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S21 = -3.034 dB (49.72%)

S31 = -3.040 dB (49.66%)

~0.61% loss

S21 = -3.022 dB (49.86%)

S31 = -3.054 dB (49.50%)

~0.64% loss

Page 7: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S21 = -3.033 dB (49.73%)

S31 = -3.039 dB (49.67%)

~0.59% loss

S21 = -3.023 dB (49.86%)

S31 = -3.089 dB (49.10%)

~1.04% loss

Page 8: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S13 = -3.040 dB (49.65%)

S43 = -3.070 dB (49.32%)

~1.03% loss

S13 = -3.055 dB (49.49%)

S43 = -3.053 dB (49.51%)

~1.00% loss

Page 9: 3-dB Power Divider and Hybrids for 8-Pack Phase II Power Distribution

S21 = -3.039 dB (49.68%)

S34 = -3.070 dB (49.32%)

~1.00% loss

S24 = -3.091 dB (49.09%)

S34 = -3.054 dB (49.50%)

~1.42% loss