2U SAS JBOD Enclosure Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your storage system. April 27, 2018 Revision 5.0 NEC Corporation
21
Embed
2U SAS JBOD Enclosure Configuration Guide - NEC · PDF file2U SAS JBOD Enclosure Configuration Guide Introduction ... 1.3 2U 2.5-inch SAS JBOD Enclosure (3) Category Product Name
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
2U SAS JBOD Enclosure
Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your storage system.
Key Features .......................................................................................................................................... 3
1.1 2U 2.5-inch SAS JBOD Enclosure (1) ................................................................................. 12
1.2 2U 2.5-inch SAS JBOD Enclosure (2) ................................................................................. 13
1.3 2U 2.5-inch SAS JBOD Enclosure (3) ................................................................................. 14
1.4 2U 2.5-inch SAS JBOD Enclosure (4) ................................................................................. 15
1.5 2U 3.5-inch SAS JBOD Enclosure (1) ................................................................................. 16
1.6 2U 3.5-inch SAS JBOD Enclosure (2) ................................................................................. 17
1.7 2U 3.5-inch SAS JBOD Enclosure (3) ................................................................................. 18
1.8 2U 3.5-inch SAS JBOD Enclosure (4) ................................................................................. 19
COPYRIGHT NOTICE AND LIABILITY DISCLAIMER ................................................. 20
REVISION HISTORY ..................................................................................................... 21
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 3
Technical Specification
Key Features Compact direct attached storage
Twenty four 2.5-inch or twelve 3.5-inch drive bays in 2U enclosure
Superior reliability with hot plug redundant power supplies and redundant fans
Specification
(1/2)
Model 2U SAS JBOD Enclosure
Part Number N8192-101F N8192-102F
Storage Maximum Capacity 28.8 TB SAS 48 TB NL SAS
Hot Plug Supported
Drive Bays 24 12
Interfaces One SFF-8088 mini-SAS Connector
Redundant Power Supply Standard, hot plug
Power Supply Two hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Maximum Power Consumption 300 Watt 310 Watt
Dimensions (W x D x H ) 482.0 x 552.9 x 87.8 mm / 19.0 x 21.8 x 3.5 in (2U)
Weight (Maximum) 29 kg, 63.93 lbs.
Temperature, Relative Humidity (non-condensing) Operating: 10° to 35° C / 50° to 95° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
(2/2)
Model 2U SAS JBOD Enclosure
Part Number N8192-103F N8192-104F
Storage Maximum Capacity 43.2 TB SAS 72 TB NL SAS
Hot Plug Supported
Drive Bays 24 12
Interfaces One mini-SAS HD Connector
Redundant Power Supply Standard, hot plug
Power Supply Two hot plug PSU
100-240 VAC ± 10% 50 / 60 Hz ± 3 Hz
Maximum Power Consumption 330 Watt 270 Watt
Dimensions (W x D x H ) 482.6 x 548.5 x 87.4 mm / 19.0 x 21.6 x 3.4 in (2U)
Weight (Maximum) 28 kg, 61.73 lbs.
Temperature, Relative Humidity (non-condensing) Operating: 5° to 40° C / 41° to 104° F, 10 to 80%
Non-Operating: -10° to 60° C / 14° to 140° F, 5 to 80%
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 4
External Views
Front and Rear Views
Front View for N8192-101F and N8192-102F
2U 2.5-inch SAS JBOD Enclosure (N8192-101F)
2U 3.5-inch SAS JBOD Enclosure (N8192-102F)
Legend
A. ID LED E. Hard Drive Activity LED B. Service LED F. Hard Drive Fault LED C. Power LED G. Drive Bays
D. Standby LED
A
B
C
D
G
E F
A
B
C
D
G
FE
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 5
Rear View for N8192-101F and N8192-102F
Legend
A. Power Switch H. Controller Ready LED
B. AC Inlet I. Controller Fault LED
C. AC Power Good LED J. ID LED
D. Power Fault LED K. SAS Link LED
E. Service Action LED L. SAS Fault LED
F. DC Power Good LED M. SFF-8088 mini-SAS Connector
G. Standby Power Good LED
B C D E F GA
LH MI J K
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 6
Front View for N8192-103F and N8192-104F
2U 2.5-inch SAS JBOD Enclosure (N8192-103F)
2U 3.5-inch SAS JBOD Enclosure (N8192-104F)
Legend
A. ID LED(Not used) D Hard Drive Activity LED B. Service LED E Hard Drive Fault LED C. Power LED
A
B
C
E D
A
B
C
D E
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 7
Rear View for N8192-103F and N8192-104F
Legend
A. Power Switch H. Debug port(Not used)
B. mini-SAS HD Connector(Not used) I. RDY LED
C. mini-SAS HD Connector(Not used) J. AC IN LED
D. mini-SAS HD Connector K. ALM LED
E. Controller Ready LED L. AC Inlet
F. Controller Fault LED M. SAS Link LED
G. ID LED(Not used) N SAS Fault LED
A B C D H
I J K L
E F G
M N
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 8
Dimensions (mm)
2U 2.5-inch SAS JBOD Enclosure N8192-101F
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 9
2U 3.5-inch SAS JBOD Enclosure N8192-102F
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 10
2U 2.5-inch SAS JBOD Enclosure N8192-103F
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 11
2U 3.5-inch SAS JBOD Enclosure N8192-104F
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 12
Unit Configuration
1 External Drive Configuration
1.1 2U 2.5-inch SAS JBOD Enclosure (1)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s
N8103-160
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9286CV-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included
N8103-161
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9285-8e
N8103-162
Cable
1 to 2 Required
External SAS Cable
2 m, 1 x SFF-8088 to 1 x SFF-8088
K410-191(02)
Enclosure
1 to 2 Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-101F
Bezel Front Bezel
For N8192-101F/102F
N8192-302F
Drive
24 slots available
300GB HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-501
450GB HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-502
600GB HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-503
900GB HDD
1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-504
1.2TB HDD
1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-508
NOTE:
Storage controllers must be compatible with the server connected.
The drive enclosures connected to one storage controller must be identical.
One drive enclosure can be connected to one port of storage controller.
Eight and more disk drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 13
1.2 2U 2.5-inch SAS JBOD Enclosure (2)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s,
Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
SAS Cable
2 m, 1 x SFF-8088 to 1 x SFF-8644
K410-322(02)
Enclosure
1 to 2 Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-101F
Bezel Front Bezel
For N8192-101F/102F
N8192-302F
Drive
24 slots available
300GB HDD
1 x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-501
450GB HDD
1 x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10000 rpm
N8192-502
600GB HDD
1 x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-503
900GB HDD
1 x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-504
1.2TB HDD
1 x 1.2 TB, SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8192-508
NOTE:
Storage controllers must be compatible with the server connected.
The drive enclosures connected to one storage controller must be identical.
One drive enclosure can be connected to one port of storage controller.
Eight and more disk drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 14
1.3 2U 2.5-inch SAS JBOD Enclosure (3)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s,
Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
SAS Cable
2 m, SFF-8644 to SFF-8644
K410-333(02)
Enclosure
1 to 2 Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-103F
Drive
24 slots available
SAS HDD (512B)
600GB 10K Hot Plug 2.5-inch SAS HDD
For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector
N8192-514
1.2TB 10K Hot Plug 2.5-inch SAS HDD
For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector
N8192-516
SAS HDD (4KB)
1.8TB 10K Hot Plug 2.5-inch SAS HDD
For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 4KB sector
N8192-513
NOTE:
Storage controllers must be compatible with the server connected.
One drive enclosure can be connected to one port of storage controller.
The drive enclosures connected to one storage controller must be identical.
At least eight drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at:
RAID0/1/5/6/10/50/60, 4GB, 8 External port PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-196
Battery Backup Battery Backup Unit
Lithium-ion Battery for RAID controller.
N8103-198
Cable
Required
SAS Cable
2 m, SFF-8644 to SFF-8644
K410-419(02)
Enclosure
Required
2U 2.5-inch SAS JBOD Enclosure
24 x 2.5-inch Hot-plug hard drive bays
N8192-103F
Drive
24 slots available
SAS HDD (512B)
600GB 10K Hot Plug 2.5-inch SAS HDD
For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector
N8192-514
1.2TB 10K Hot Plug 2.5-inch SAS HDD
For N8192-103F, 2.5-inch SAS 10K HDD, 12Gb/s, 512B sector
N8192-516
NOTE:
Storage controllers must be compatible with the server connected.
Only one SAS JBOD Enclosure can be connected to one RAID controller.
The drive enclosures connected to one storage controller must be identical.
At least eight drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 16
1.5 2U 3.5-inch SAS JBOD Enclosure (1)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9285-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 2.0 x8, SAS 6Gb/s, SATA 6Gb/s
N8103-160
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9286CV-8e
RAID0/1/5/6/10/50/60, 1GB, Ext. 8, PCIe 3.0 x8, SAS 6Gb/s, SATA 6Gb/s, flash cache protection modules included
N8103-161
RAID BBU
Recommended for N8103-160
RAID Battery Backup Unit
for N8103-160 LSI MegaRAID SAS 9285-8e
N8103-162
Cable
1 to 2 Required
External SAS Cable
2 m, 1 x SFF-8088 to 1 x SFF-8088
K410-191(02)
Enclosure
1 to 2 Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-102F
Bezel Front Bezel
For N8192-101F/102F
N8192-302F
Drive
12 slots available
1TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-505
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm
N8192-506
3TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-507
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-509
NOTE:
Storage controllers must be compatible with the server connected.
The drive enclosures connected to one storage controller must be identical.
One drive enclosure can be connected to one port of storage controller.
Four or more disk drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 17
1.6 2U 3.5-inch SAS JBOD Enclosure (2)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s,
Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
SAS Cable
2 m, 1 x SFF-8088 to 1 x SFF-8644
K410-322(02)
Enclosure
1 to 2 Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-102F
Bezel Front Bezel
For N8192-101F/102F
N8192-302F
Drive
12 slots available
1TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 1 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-505
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 2 TB NL SAS HDD,32.5-inch, 6Gb/s, 7,200 rpm
N8192-506
3TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 3 TB NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-507
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
1 x 4 TB, NL SAS HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8192-509
NOTE:
Storage controllers must be compatible with the server connected.
The drive enclosures connected to one storage controller must be identical.
One drive enclosure can be connected to one port of storage controller.
Four or more disk drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 18
1.7 2U 3.5-inch SAS JBOD Enclosure (3)
Category Product Name / Description Part Number
Storage Controller
Required
RAID Controller (2GB, RAID0/1/5/6)
LSI MegaRAID SAS 9380-8e
RAID0/1/5/6/10/50/60, 2GB, Ext. 8, PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s,
Flash cache protection modules included
N8103-179
Cable
1 to 2 Required
SAS Cable
2 m, SFF-8644 to SFF-8644
K410-333(02)
Enclosure
1 to 2 Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-104F
Drive
12 slots available
SAS HDD (512B)
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector
N8192-520
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector
N8192-522
SAS HDD (4KB)
6TB 7.2K Hot Plug 3.5-inch NL SAS HDD
For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 4KB sector
N8192-519
NOTE:
Storage controllers must be compatible with the server connected.
The drive enclosures connected to one storage controller must be identical.
One drive enclosure can be connected to one port of storage controller.
At least four drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
When you select 4KB sector HDD, confirm whether your applications support hard drives with 4 KB sector size. For more information, visit the NEC website at:
RAID0/1/5/6/10/50/60, 4GB, 8 External port PCIe 3.0 x8, SAS 12Gb/s, SATA 6Gb/s
N8103-196
Battery Backup Battery Backup Unit
Lithium-ion Battery for RAID controller.
N8103-198
Cable
Required
SAS Cable
2 m, SFF-8644 to SFF-8644
K410-419(02)
Enclosure
Required
2U 3.5-inch SAS JBOD Enclosure
12 x 3.5-inch Hot-plug hard drive bays
N8192-104F
Drive
12 slots available
SAS HDD (512B)
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD
For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector
N8192-520
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD
For N8192-104F, 3.5-inch NL-SAS 7.2K HDD, 6Gb/s, 512B sector
N8192-522
NOTE:
Storage controllers must be compatible with the server connected.
Only one SAS JBOD Enclosure can be connected to one RAID controller.
At least four drives must be installed.
All hard drives within a RAID array should be of the same capacity and rotation speed.
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk of becoming multiple hard drives failure.
Any of RAID arrays cannot be used as a boot device.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 20
Copyright Notice and Liability Disclaimer The information contained herein is subject to change without notice.
All other products, brands, or trade names used in this document are trademarks or registered trademarks of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
CONFIGURATION GUIDE – 2U SAS JBOD Enclosure
NEC Corporation Revision 5.0 – April, 2018 21
Revision History
Revision Date Description
5.0 April 27, 2018 Others:
Added RAID Controller information for new servers.
4.0 July 24, 2015 New products added:
2U 2.5-inch SAS JBOD Enclosure N8192-103F
600GB 10K Hot Plug 2.5-inch SAS HDD N8192-514
1.2TB 10K Hot Plug 2.5-inch SAS HDD N8192-516
1.8TB 10K Hot Plug 2.5-inch SAS HDD N8192-513
2U 3.5-inch SAS JBOD Enclosure N8192-104F
2TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-520
4TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-522
6TB 7.2K Hot Plug 3.5-inch NL SAS HDD N8192-519
Front Bezel N8192-303F
SAS Cable K410-333(02)
3.0 February 13, 2015 Other:
Corrected the type of SAS cable to connect with N8103-179 RAID Controller and JBOD