Top Banner
Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure (3) .A platinum foil specimen is suspended in a solution contain unit activity H + which is bubbled with purified hydrogen to removed dissolved oxygen and establish the standard state for H 2 at 1 atm pressure. Figure (3) standard hydrogen electrode The hydrogen electrode is connected to another half-cell through a solution bridge which contains a porous glass barrier to permit charge transfer and potential measurement but not mass transfer of the acid solution in the electrode. 2-Standard Calomel Electrode The calomel reference electrode has long been a standard reference electrode used in lab. it consists of mercury in equilibrium with 2 2 + Hg the half cell reaction is - - + ® + Cl Hg e Cl Hg 2 2 2 2 2 v E 268 . 0 = o Figure (4) show the calomel electrode apparatus
4

®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure

Apr 04, 2018

Download

Documents

vuongnhu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure

Reference Electrodes

1-Standard Hydrogen Electrode SHE

The schematic construction of hydrogen reference electrode is in figure (3) .A platinum foil specimen is suspended in a solution contain unit activity H+ which is bubbled with purified hydrogen to removed dissolved oxygen and establish the standard state for H2 at 1 atm pressure.

Figure (3) standard hydrogen electrode

The hydrogen electrode is connected to another half-cell through a solution bridge which contains a porous glass barrier to permit charge transfer and potential measurement but not mass transfer of the acid solution in the electrode.

2-Standard Calomel Electrode

The calomel reference electrode has long been a standard reference electrode used in lab. it

consists of mercury in equilibrium with 22+Hg the half cell reaction is

-- +®+ ClHgeClHg 22222 vE 268.0=o

Figure (4) show the calomel electrode apparatus

Page 2: ®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure

A combination of Hg2Cl2 , mercury and a solution of chloride ions provides very stable and reproducible potential and for convenience of use in laboratories , the chloride solution is a saturated solution of potassium chloride KCl , in this case the standard calomel electrode is called saturated calomel electrode ( SCE). Electrode potential = 0.24 volt at 298 ○K

The mercurous chloride and mercury are at unit activity . Therefore , the electrode potential can be written as:

]log[2

0592.0 --= ClEEcalomelo

The electrode potentials of calomel electrode

Electrode Potential (volt) Hg/Hg2Cl2/KCl(1.0 N) 0.289 Hg/Hg2Cl2/KCl(0.1 N) 0.3356

3- Silver-Silver Chloride electrode

This electrode is composed of a silver wire coated with silver Chloride and immersed in a solution of chloride ions, the overall electrode l reaction is :

-- +®+ ClAgeAgCl

Page 3: ®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure

The Nernst equation gives the electrode potential

]log[0592.0222.0/--= ClE AgClAg

It is clear that the potential is dependent on Cl- same as for calomel electrode , When at low concentration – log (Cl-) in above equation can be replaced by pH:

pHE AgClAg 0592.0222.0/ +=

Other two reaction involve a dynamic equilibrium of deposition and dissolution of silver together with solubility equilibrium between silver chloride and its ions

The following are the values of EAg/AgCl for different HCl concentration

Concentration (M) Electrode potential (volt) 0.1 0.28

0.01 0.34 0.001 0.40

4-copper-copper sulfate electrode

This is a reference electrode which is easy robust and stable , it is used mainly in cathodic protection measurements such as the measurement of pipe-to-soil potential. It has lower accuracy than other electrodes .It consists of copper metal placed in a solution contain copper sulfate placed in non conducting holder with a porous plug .the copper sulfate crystals maintain the solution at a fixed ion concentration and it is easily to recharged when it becomes contaminated.

vE CuSOCu 316.04/ =o

The reaction of Cu-CuSO4 half cell is :

CueCu =+ -+ 22

The electrode potential :

Page 4: ®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure

]log[2

0592.034.0 2/ 4

++-= CuE CuSOCu