Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure (3) .A platinum foil specimen is suspended in a solution contain unit activity H + which is bubbled with purified hydrogen to removed dissolved oxygen and establish the standard state for H 2 at 1 atm pressure. Figure (3) standard hydrogen electrode The hydrogen electrode is connected to another half-cell through a solution bridge which contains a porous glass barrier to permit charge transfer and potential measurement but not mass transfer of the acid solution in the electrode. 2-Standard Calomel Electrode The calomel reference electrode has long been a standard reference electrode used in lab. it consists of mercury in equilibrium with 2 2 + Hg the half cell reaction is - - + ® + Cl Hg e Cl Hg 2 2 2 2 2 v E 268 . 0 = o Figure (4) show the calomel electrode apparatus
4
Embed
®2Hg E - جامعة بابل | University of Babylon · Reference Electrodes 1-Standard Hydrogen Electrode SHE The schematic construction of hydrogen reference electrode is in figure
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Reference Electrodes
1-Standard Hydrogen Electrode SHE
The schematic construction of hydrogen reference electrode is in figure (3) .A platinum foil specimen is suspended in a solution contain unit activity H+ which is bubbled with purified hydrogen to removed dissolved oxygen and establish the standard state for H2 at 1 atm pressure.
Figure (3) standard hydrogen electrode
The hydrogen electrode is connected to another half-cell through a solution bridge which contains a porous glass barrier to permit charge transfer and potential measurement but not mass transfer of the acid solution in the electrode.
2-Standard Calomel Electrode
The calomel reference electrode has long been a standard reference electrode used in lab. it
consists of mercury in equilibrium with 22+Hg the half cell reaction is
-- +®+ ClHgeClHg 22222 vE 268.0=o
Figure (4) show the calomel electrode apparatus
A combination of Hg2Cl2 , mercury and a solution of chloride ions provides very stable and reproducible potential and for convenience of use in laboratories , the chloride solution is a saturated solution of potassium chloride KCl , in this case the standard calomel electrode is called saturated calomel electrode ( SCE). Electrode potential = 0.24 volt at 298 ○K
The mercurous chloride and mercury are at unit activity . Therefore , the electrode potential can be written as:
This electrode is composed of a silver wire coated with silver Chloride and immersed in a solution of chloride ions, the overall electrode l reaction is :
-- +®+ ClAgeAgCl
The Nernst equation gives the electrode potential
]log[0592.0222.0/--= ClE AgClAg
It is clear that the potential is dependent on Cl- same as for calomel electrode , When at low concentration – log (Cl-) in above equation can be replaced by pH:
pHE AgClAg 0592.0222.0/ +=
Other two reaction involve a dynamic equilibrium of deposition and dissolution of silver together with solubility equilibrium between silver chloride and its ions
The following are the values of EAg/AgCl for different HCl concentration
This is a reference electrode which is easy robust and stable , it is used mainly in cathodic protection measurements such as the measurement of pipe-to-soil potential. It has lower accuracy than other electrodes .It consists of copper metal placed in a solution contain copper sulfate placed in non conducting holder with a porous plug .the copper sulfate crystals maintain the solution at a fixed ion concentration and it is easily to recharged when it becomes contaminated.