CERTIFICATE Certified Passive House Component Passive House Institute Dr. Wolfgang Feist 64283 Darmstadt Germany Component-ID 0885wi03 valid until 31st December 2018 www.passivehouse.com Category: Window Frame Manufacturer: FANZOLA SNC, Rosta, Italy Product name: EVO NULL 68 This certificate was awarded based on the following criteria for the cool, temperate climate zone Comfort U W = 0.79 ≤ 0.80 W/(m 2 K) U W ,installed ≤ 0.85 W/(m 2 K) with U g = 0.70 W/(m 2 K) Hygiene f Rsi =0.25 ≥ 0.70 CERTIFIED COMPONENT Passive House Institute cool, temperate climate ph A Passive House efficiency class phE phD phC phB phA
4
Embed
2/4 EVO NULL 68 - Passive House Institute · 2017. 12. 21. · Product name: EVO NULL 68 This certificate was awarded based on the following criteria for the cool, temperate climate
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
CERTIFICATECertified Passive House Component
Passive House InstituteDr. Wolfgang Feist64283 Darmstadt
GermanyComponent-ID 0885wi03 valid until 31st December 2018
www.passivehouse.com
Category: Window FrameManufacturer: FANZOLA SNC,
Rosta,Italy
Product name: EVO NULL 68
This certificate was awarded based on the followingcriteria for the cool, temperate climate zone
FANZOLA SNCVia Stazione 4, 10090 Rosta, ItalyT + 39 0119540148 |B [email protected] | Í http://www.fanzola.it |
20 o
C
18 o
C
16 o
C
14 o
C
12 o
C
10 o
C
8 o
C
6 o
C
4 o
C
2 o
C
0 o
C
-2 o
C
-4 o
C
-6 o
C
-8 o
C
-10 o
C
Calculation model Isothermal
Description
Timberframe with installation frame of dense PIR-foam (λ = 0.086 W/(mK)) and insulation of cork (λ =0,040 W/(mK)). Integrated drainage through installation system. Pane thickness: 49 mm (6,36/16/4/16/6,36),rebate depth: 18mm, spacer: Swisspacer ULTIMATE
Explanation
The window U-values were calculated for the test window size of 1.23 m× 1.48 m with Ug = 0.70 W/(m2 K).If a higher quality glazing is used, the window U-values will improve as follows:
Glazing Ug = 0.70 0.64 0.58 0.52 W/(m2 K)↓ ↓ ↓ ↓
Window UW = 0.79 0.74 0.70 0.65 W/(m2 K)
Transparent building components are classified into efficiency classes depending on the heat lossesthrough the opaque part. The frame U-Values, frame widths, thermal bridges at the glazing edge, andthe glazing edge lengths are included in these heat losses. A more detailed report of the calculationsperformed in the context of certification is available from the manufacturer.
The Passive House Institute has defined international component criteria for seven climate zones. Inprinciple, components which have been certified for climate zones with higher requirements may alsobe used in climates with less stringent requirements. In a particular climate zone it may make senseto use a component of a higher thermal quality which has been certified for a climate zone with morestringent requirements.
Further information relating to certificationcan be found on www.passivehouse.com and passipedia.org.