This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
High pressure filters
127
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Flow (l/min)
∆p(bar)
02QH
Flow (US GPM)
∆p(PSID)
0
7.3
14.5
21.8
29.0
36.3
43.5
05QH10QH
20QH
0 13 26 66
50 100 2502000
53
150 300
39 79
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Flow (l/min)∆p(bar)
02QH
Flow (US GPM)
∆p(PSID)
0
7.3
14.5
21.8
29.0
36.3
43.5
05QH
10QH
20QH
0 13 26 66
50 100 2502000
53
150 300
39 79
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Flow (l/min)
∆p(bar)
02QH
Flow (US GPM)
∆p(PSID)
0
7.3
14.5
21.8
29.0
36.3
43.5
05QH
10QH
20QH
0 13 26 66
50 100 2502000
53
150 300
39 79
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Flow (l/min)
∆p(bar)
02QH
Flow (US GPM)
∆p(PSID)
0
7.3
14.5
21.8
29.0
36.3
43.5
05QH
10QH
20QH
0 13 26 66
50 100 2502000
53
150 300
39 79
22PD-1 High Collapse Elements
32PD-1 High Collapse Elements
22PD-2 High Collapse Elements
32PD-2 High Collapse Elements
Ordering Information
Note: Filter assemblies ordered from the product configurator on the next page are on extended lead times. Where possible, please make your selection from the table above.
Part number
22PD210QBM3KG161
22PD210QBT1KG161
22PD220QBM3KG161
22PD220QBT1KG161
32PD210QBM3KG201
32PD210QBT1KG201
32PD220QBM3KG201
32PD220QBT1KG201
Supersedes
0-22-PD-2-10Q-V-50-C-1
0-22-PD-2-10Q-TW3-50-C-1
0-22-PD-2-20Q-V-50-C-1
0-22-PD-2-20Q-TW3-50-C-1
0-32-PD-2-10Q-V-50-D-1
0-32-PD-2-10Q-TW3-50-D-1
0-32-PD-2-20Q-V-50-D-1
0-32-PD-2-20Q-TW3-50-D-1
Flow
(l/min)
120
120
140
140
240
240
260
260
Model
number
22PD
22PD
22PD
22PD
32PD
32PD
32PD
32PD
Element
length
Length 2
Length 2
Length 2
Length 2
Length 2
Length 2
Length 2
Length 2
Media
rating (µ)
10
10
20
20
10
10
20
20
Seals
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Nitrile
Indicator
Visual
Electrical
Visual
Electrical
Visual
Electrical
Visual
Electrical
Bypass
settings
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
3.5 bar
Replacement
elements
G01315Q
G01315Q
G01938Q
G01938Q
G01098Q
G01098Q
G01954Q
G01954Q
Ports
G1"
G1"
G1"
G1"
G11/4"
G11/4"
G11/4"
G11/4"
Standard products table
High Pressure Duplex Filters
22PD/32PD SeriesOrdering Information (cont.)
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 16
128
Product configurator
Box 1
Code
1
2
Length
Length 1
Length 2
Filter type
Box 2
22PD
Box 2
2
Box 3
10Q
Box 4
B
Box 5
M3
Box 6
K
Box 7
G16
Box 8
1
Code
B
V
Seal material
Nitrile
Fluoroelastomer
Seal type
Box 4
Bypass valve
3.5 bar
No bypass
No bypass
Bypass and indicator settings
Indicator
2.5 bar
5.0 bar
No indicator
+ Box 8: code 2
+ Box 8: code 2
Code
K
M
X
Box 6
Code
M3
T1
P
N
F1
F2
F3
F4
Visual indicator
Electrical indicator
Plugged with steel plug
No indicator port
Electronic 4 LED, PNP, N.O.
Electronic 4 LED, NPN, N.O.
Electronic 4 LED, PNP, N.C.
Electronic 4 LED, NPN, N.C.
Indicator
Box 5
Code
1
2
Options
Standard
No bypass
Options
Box 8
Code
22PD
32PD
Model
Small high pressure duplex filter
Large high pressure duplex filter
Code
Box 1
Note 1: Part numbers featured with bold highlighted codes
will ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will
require you to contact Parker Filtration for availability.
Code
G16
R20
G20
R24
Ports
22PD: Thread G 1
SAE flange 1 1/4" 3000-M
32PD: Thread G 1 1/4
SAE flange 1 1/2" 3000-M
Filter connection
Box 7
Media
02Q
05Q
10Q
20Q
02QH
05QH
10QH
20QH
Replacement elements with nitrile seals
22PD-1
G01282Q
G02721Q
G01281Q
G01930Q
G01442Q
G03737Q
G01441Q
G01932Q
22PD-2
G01316Q
G02724Q
G01315Q
G01938Q
G01448Q
G03738Q
G01447Q
G01940Q
32PD-1
G01069Q
G02567Q
G01068Q
G01946Q
G01454Q
G03739Q
G01453Q
G01948Q
32PD-2
G01099Q
G02727Q
G01098Q
G01954Q
G01460Q
G03740Q
G01459Q
G01956Q
Media
02Q
05Q
10Q
20Q
02QH
05QH
10QH
20QH
Replacement elements with fluoroelastomer seals
22PD-1
G01302Q
G02723Q
G01301Q
G01934Q
G01446Q
G04235Q
G01445Q
G01935Q
22PD-2
G01336Q
G02726Q
G01335Q
G01942Q
G01452Q
G04236Q
G01451Q
G01943Q
32PD-1
G01089Q
G02569Q
G01088Q
G01950Q
G01458Q
G04237Q
G01457Q
G01951Q
32PD-2
G01119Q
G02729Q
G01118Q
G01958Q
G01464Q
G04238Q
G01463Q
G01959Q
Filter model
22PD-1
22PD-2
32PD-1
32PD-2
Nominal flow (I/min) at viscosity 30 cSt
02Q
70
100
100
180
05Q
80
110
150
210
10Q
100
120
210
240
20Q
120
140
230
260
Filter model
22PD
32PD
Seal kits
Nitrile
S04233
S02373
Fluoroelastomer
S04234
S02375
When filter includes a bypass valve but not an indicator,
code denotes bypass setting.
Item is standard
Item is standard green option
Item is semi standard
Item is non standard
123
123
123
123
Highlights Key (Denotes part number availability)
Note: Standard items are in stock, semi standard items are available within four weeks
Box 3
Element media
Microglass III element
High collapse element
20Q
20QH
10Q
10QH
05Q
05QH
02Q
02QH
Glass fibre
Media code
Degree of filtration
Average filtration beta ratio ß (ISO 16889) / particle size µm [c]
% efficiency, based on the above beta ratio (ßx)
ßx(c)=2
50.0%
N/A
N/A
N/A
6
Degree of filtrationCode
ßx(c)=10
90.0%
N/A
N/A
6
11
ßx(c)=75
98.7%
N/A
4.5
8.5
17
ßx(c)=100
99.0%
N/A
5
9
18
ßx(c)=200
99.5%
N/A
6
10
20
ßx(c)=1000
99.9%
4.5
7
12
22
02Q
05Q
10Q
20Q
Disposable
Microglass III
02QH
05QH
10QH
20QH
High collapse
element
Portable Hydraulic Filtration Systems
Guardian®
MAX 15 I/min - 2 bar
Portable filtration systems
129
Portable Hydraulic Filtration Systems
Guardian®
Typical Applications
The Parker Filtration Guardian®
portable filtration systems.
Guardian is a portable filtration system with two
main functions: to ensure that new ‘dirty’ fluid
often contaminated during handling, is delivered
to the system at a specific cleanliness; and to
permit periodic clean up of existing fluid to
original condition.
Recommended fluids: Petroleum based oils,
water emulsions and diesel fuels.
Features & Benefits Application Example
• Fluid transfer
• Offline reservoir clean-up
• Injection moulding machines
• Royal navy surface fleet systems
• Paper mills
• Industrial equipment
• Mobile equipment
• Marine system support
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 17
130
Features
Portable and robust
design
Lightweight design
Quick disconnect
hose connections
Visual indicator
110VAC or
220/240VAC options
A range of clean-up
elements
Water removal element
option
Advantages
Guardian is designed to be used anywhere.
Take it to the system or transfer new oil
from the drum.
Only 10.6 kg
Storage is simple. Guardian’s compact
design means it is easily stowed.
Operational condition is constantly monitored
Guardian’s power flexibility means it can
be used anywhere.
A user can specify the media that will best
achieve his clean up/filtering requirements.
Water removal from the system is an
important requirement for fluid efficiency.
A hydraulic system reservoir had become heavily
contaminated and the hydraulic system was in danger of a
catastrophic failure from particulate and water contamination.
These contaminants were introduced from various points
– airborne, wear and introduction of new ‘dirty’ fluids. The
Guardian filtration system was installed into the hydraulic
systems reservoir and run completely off-line for a period of
time until acceptable contamination levels were achieved.
This off-line attachment allowed the hydraulic system to
continue operating without costly downtimes. Additionally a
Water Removal (WR) Element was also fitted to the Guardian,
which radically reduced the water contamination within the
entire system.
This customer will ‘only now’ introduce new fluids into his
hydraulic application by using the Guardian filtration system
and in addition utilises the Guardian off-line option to maintain
and protect his system.
Contamination levels are monitored by an LCM202021 which
controls the Guardians operation.
Result: reliability and complete confidence restored.
Note: 15 l/min / Fluid transfer at a controlled rate
Portable filtration systems
Specification
131
Vibration isolating rubber feet 4-pls
Quick access zero leakage 3/4” -
11.5 NH hose connections
3/4” wire reinforced flexible outlet
hose, 1.6m (63 inches) length
inlet hose, 1.6m
(63 inches) length 3/4” wire reinforced
flexible outlet hose,
1.6m (63 inches) length
3/4” – 11.5 NH hose thread (outlet)
Motor is UL recognised & CSA listed
Visible & easily cleanable inlet strainer
Inlet
Outlet
195mm (7.68”)
394mm
(15.57”)
152mm
(5.98”)
51mm (2.00”)
On/off switch
Alternative customer selectable inlet and outlet ports (plugged)
Removable element
Non conductive
carrying handle1.7 bar differential
visual indicator 140 minimum element
removal clearance
208mm
Portable Hydraulic Filtration Systems
Guardian®
Ordering Information and Product Configurator
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 17
132
Part number
GT4E110Q1UK
GT4E110Q1EUR
GT4E210Q1IND
Supersedes
F3-GT4E-1-10Q-1-UK
F3-GT4E-1-10Q-1-EUR
F3-GT4E-2-10Q-1-IND
Model (fluorocarbon)
GT4E
GT4E
GT4E
Motor
option
1
1
2
Element
(µ)
10Q
10Q
10Q
Options
1
1
1
Plug type
UK
EUR
IND
Replacement
element
G04396Q
G04396Q
G04396Q
Model (fluorocarbon)
GT4E
Motor options
1
2
3
220/240 VAC
* 110 VAC
~ 24 Vdc
Options
1
6
None
Quick disconnect
hose connections
Plug type
UK
EUR
IND
CL
United Kingdom
Europe
Industrial 3 pin
*110 version only
~ Battery clamps
(24Vdc Only)
Part number
G04396Q
G04394Q
G04395Q
G04397Q
G04400
G04401
G04402
G04403
Guardian replacement elements to ISO16889
Micron rating
10
4.5
6
20
25
40
74
WR
Media type
Microglass III
Microglass III
Microglass III
Microglass III
Wire mesh
Wire mesh
Wire mesh
Water removal
Replacement elements
Note 1: Part numbers featured with bold highlighted codes will
ensure a ‘standard’ product selection.
Note 2: Alternate displayed part number selection will require you
to contact Parker Filtration for availability.
Product configurator
Standard products table
Element (µ)
10Q
02Q
05Q
20Q
25W
40W
74W
WR
Microglass
Wire mesh
Water removal
Hydraulic Service Equipment
Filtration UnitMAX 15 I/min - 6 bar
Portable filtration systems
133
Hydraulic Service Equipment
Filtration Unit
Typical Applications
Fluid transfer
Small lubrication systems
Constant flushing loops
Maintenance flushing
Offline filtration in circuits
where pressure and flow
pulses are expected
The Parker Filtration Service Equipment.
Designed to offer both permanent offline cleaning
where higher levels of contamination are expected
and portable additional clean-up capability as part
of your preventative maintenance package.
Features & Benefits
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 18
134
Features
Single phase and three phase
motor options
15 l/min flow
Red/green visual indicator
Robust construction
Spin-on element
Lightweight design
Advantages
Flexibility of power output
Fluid transfer at a controlled rate
Clear indication of condition during operation
Reliability designed in
Easy change element
Easy to locate when and where required
Benefits
End user choice dependent on
application
Reliable fluid transfer from drum to
system
High visibility during operation
Designed to be used even in the most
demanding conditions
10 micron Abs. elements
Take the unit to the application.
It’s that easy
Portable filtration systems
Installation Details
Specification
Electric motorFrame Size: IEC Frame 63. Foot and flange ‘D’
(Flange IEC.F115). Totally enclosedfan cooled.
Windings: 380/420 volt 3 ph/50 Hz, 220 Volt 1ph/50 Hz 110 Volt 1 ph/50 Hz.
Power: 0.18 kW (1/4 hp).Speed: 1400 rev/min.
It is recommended that the Unit is wiredindependently from the main system whenpermanently installed, to facilitate the simplechanging of the filter element without interruptingthe main system.
Filtration unit descriptionThe Parker ‘Filtration Unit’ consists of an electricmotor directly coupled to a hydraulic pump,which has a built in bypass fitted and spin on filterelement. Fluid drawn in at pump inlet is circulatedthrough the filter element and is thus cleanedbefore being delivered from the outlet port. A builtin bypass valve safeguards the element in the eventof blockage and returns oil to the pump inlet, thisensures that all fluid output from the unit is filtered,whatever the operating conditions. A visual elementcondition indicator is fitted to the pump. A unit isavailable without electric motor for customers whoprefer to supply their own. See installation notesand part numbers for ordering.
Pump and bypass valvePump: Lobe type for quiet running.Flow: 15 l/min.Connections: Inlet G1/2 (1/2” BSP).
OutletG3/8 (3/8” BSP).Bypass Valve: Cracks at 1.5 bar approximately. Bypassed oil is recirculated within
the pump. Bypassed oil is reintroduced into the inlet port and doesnot pass the filter. Bypass operates when the element is
contaminatedand needs replacing. This condition will be made clear by the visualindicator. The Bypass Valve could also open when being used withhigh viscosity fluids, thus effectively reducing the unit output.
Filter and condition indicatorFilter Type: Rapid replacement spin-on can with 10µ cellulose element.
Ensure that end clearance (20mm) is available topermit element withdrawal.10µ nominal. MXR8550
Visual indicatorHas green and red zones on the dial. Needle in the green zone indicates normaloperation. When the needle enters the red zone, the bypass valve will permit a flowof oil to return to the pump inlet – The element will then need to be replaced. Thebypass is fully open when the needle is at the extreme of the red sector.
Sound levelThe Filtration Unit under normal conditions will operate at a sound pressure level ofapproximately 65 dBA.
135
432
(17.0)A
75
(2.95)
71
(2.80)
177
(6.97)
147
(5.78)
8
(0.31)
45
(1.77)
90 CRS
(3.54)
4 x Ø7
4 x (0.27)
1/2” BSP (G 1/2)
3/8” BSP (G 3/8)
20
(0.79)
Ø94
(3.70)
Ø125(4.92)
Ø140(5.51)
155 (6.1)
100 (3.94)
66
(2.60)105 (4.13)
131 (5.16)
Ø140 (5.51)
112 CRS (4.76)
mm
(inches)
Single Three
phase phase
Dimension A 221 184
(8.70) (7.24)
Dimension B 45 25
(1.77) (0.98)
Hydraulic Service Equipment
Filtration Unit
Installation and Operational Notes
The Filtration Unit is suitable for mineral based oils. Maximum
viscosity at start up condition 850 centistokes-minimum
viscosity 8 centistokes. Note that at 850 centistokes output
will be reduced due to opening of bypass. Maximum operating
temperature +90°C (194°F).
The inlet pipe should be as large and as short as convenient
to reduce inlet depression to a minimum. It should not be less
than 12mm (0.47”) internal diameter.
Suction element SE75111110 is supplied with all assemblies
and must be installed. Ensure that a minimum 75mm (2.95”)
head of oil is maintained above the suction element.
The outlet pipe should be as large as possible to reduce
the possibility of delivery pressure exceeding the bypass
valve setting. It should not be less than 10mm (0.39”) internal
diameter. The discharge end of this pipe should always
be below the oil surface to minimise aeration. It is equally
important, to ensure the ends of the inlet and outlet pipes
are as far apart as possible. It is recommended that a baffle
be positioned between the suction and return pipes, to give
maximum circulation of oil.
Installation details – 2742
The Filtration Unit is available without an electrical motor, any
type motor may be used of identical frame, flange and shaft
size to that stated in the specification. Remove the key, fitted
to electric motor shaft. There are four nuts and bolts M8-
1.25mm thread supplied loose, the pump housing is complete
with a shaft adaptor with internal drive pin.
To fit pump to electric motor simply insert drive shaft of motor
into the pump drive adaptor ensuring the drive pin engages
in shaft keyway and that the locating spigot are correctly
engaged. Complete the assembly by fitting the four nuts,
bolts and washers.
Sectioned Detail
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 18
136
M
Inlet
Outlet
Circuit symbol
Out
In
Pump delivery of oil
900 L (235 USG)/HR
10µ ‘Multipass’
tested element
Integral bypassVarious electronic
motor options
Enlargement of
bypass valve
Description
Portable filtration systems
Ordering Information
Ideal Application
137
90 CTRS
(3.54)70
(2.75)
4-off holes Ø7 (motor fleet)
tap M6 for installation
20
(0.78)
Element withdrawal
clearance minimumInlet G1/2 (1/2 BSP)
Suction flange
Outlet
G3/8 (3/8 BSP)
Return bush
Oil level
112 CTRS
(4.41)
12 bore
minimum
10 bore minimum
(0.39)Baffle recommended
SE75111110
Suction element
250 minimum
(9.84)
12
(0.47)
75(2.95)
minimum
Element condition indicatorGreen area – bypass closedEntering red area – bypass crackedExtreme of red area – bypassfully open.
Part number
10µ nom filtration pump complete with 3 phase electric motor
(380/420/50 Hz H.E.F.C class F) visual indicator
10µ nom filtration pump without electric motor (supplied with
4 x nuts,bolts and washers) visual indicator
10µ nom filtration pump complete with single phase electric
motor (220/50 Hz T.E.F.C class F) visual indicator
10µ nom filtration pump complete with single phase electric
motor (110/50 Hz T.E.F.C class F) visual indicator
5.92 Kg
(13.02 lbs)
1.50 Kg
(3.3 lbs)
6.20 Kg
(13.64 lbs)
6.20 Kg
(13.64 lbs)
MXR8550
(10µ nominal)
Weight Replacement elements
2741
2742
2743
2744
Note 1: Part numbers featured with bold highlighted codes will ensure a ‘standard’ product selection
Note 2: Alternate displayed part number selection will require you to contact Parker Filtration for Availability
Standard products table
Notes
138 Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK.
Portable Filtration Trolley
10MF SeriesMAX 38 I/min
Portable filtration systems139
Portable Filtration Trolley
10MF Series
Typical Applications
Paper mills
Injection and blow moulding equipment
Industrial & mobile equipment
Transferring fluid from drums or storage tanks
to system reservoirs
Off-line conditioning of existing fluids
Complimenting existing system filtration
Features & Benefits
Parker Hannifin
Hydraulic Filter Division Europe
FDHB200UK. Section 19
140
Fluid flow path through 10MF portable filtration system when viewed
from front, electrical switch to rear
The 10MF Portable Filtration System is ideal for:
Off-line contamination control of fluid systems
Replenishing installations with filtered fluid
Emptying waste fluid quickly
The 10MF Filter system is designed for on-site preventive maintenance
of fluid systems. Two high capacity filters are used, with fluid passing
through a primary clean-up filter and then through the final polishing
filter giving highly effective and reliable contamination control.
Two high capacity filters, complete with indicators element
condition
Filters incorporate standard Parker media.
38 l/min pressure balanced gear pump
0.75kW @ 3450rpm electric motor with themal overload
protection
Robust all welded steel trolley, complete with drip tray and
rubber
tyred wheels
Complete with stowable hoses
The Parker Filtration 10MF portable filtration system.
Parkers portable filtration units are designed for on-site
preventative maintenance of fluid systems. An internal pump
draws fluid through a primary clean-up filter and then pushes
the fluid through a high quality polishing filter to remove
particulate contamination down to 4µm (c) absolute.
Water can also be removed by installing Parker’s Par-Gel™
water removal elements to the outlet filter. Once the water
comes into contact with the Polymer element it will be removed
from the fluid. An all round solution for contamination control in
your critical system
Portable filtration systems
Specification
Pump drive options:0.75kW Electric motor 220/240v A.C. Singlephase 50HZ 0.75kW Electric motor 110VA.C. Single phase 50HZ.
Pump:38 l/min pressure balanced gear pump.
Filters:Moduflow CF2.1 & RF2.1 filters.
Electrical details:On/Off switch. 2 metre cable.
Weight:45.4 kg.
Fluid compatibility:Suitable for use with mineral oils. For otherfluids, please consult Parker Filtration.
Max recommended fluid viscosity:108 cSt.
Seals:Nitrile.
Filter elements:Inlet - synthetic, stainless steel mesh optional.Outlet - 10Q Microglass III, other µ ratings and WR optional.
Filter bypass valve settings:Inlet - 0.2 bar (3 psi).Outlet - 1.7 bar (25 psi).
Visual indicator:3 band visual differential (clean, change, bypass).
3. Use the capacity curve for Modulflow element P/N 927584.
Capacity = 80cc at 40cSt & 40 Ipm to pressure drop of 1.7 bar.
(See graph below)
80cc x 0.0001 Ipm = 0.076 Ipm/element
CC
4. 0.53 litres total water = 7 elements*
0.076 Ipm/element
* The replacement value of this fluid may range from €1500.00 to €4500.00 (€0.50 to €1.25 litre).An estimated element cost of €150.00 each, the saving could be as much as €3000.00!
Using Par-Gel filter elements saves money in fluid and replacement component
costs. Also, the frequency of fluid disposal and the problems associated with it are
greatly reduced.
Filter capacity. There are no accepted and approved water capacity testing or
reporting standards. Consequently, there is virtually no way to compare one element
capacity with another. It is also difficult to simulate a specific application in testing...
making it hard to predict field performance.
Why the discrepancies? Water removal media capacity is the result of the interplay of
four variables: flow rate, viscosity, bypass setting and the media itself.
Here’s an example: two identical elements, testing the same fluid, varying only the
flow rate.
This is a 15% reduction in capacity, due to changing only the flow rate! Now, look at
what happens when the test flow rate is the same and the viscosity is changed.
Twice the capacity can be achieved just by manipulating the test viscosity!
Naturally, having a lower bypass valve setting limits the capacity. Since the life of
the element is measured in pressure drop, using higher bypass valve settings will
increase apparent life (all other conditions equal).
We recommend 1.7 bar bypass valves to get adequate life from Par-Gel filter elements.
Capacity also depends on the media itself. That’s why Parker spent two years
researching the media used in Par-Gel filter elements. We tested all known media,
and worked closely with our suppliers to achieve maximum water absorbency.