+=========================================================== HELP FULL COMMAND FOR MOSHELL_CPP_CYGWIN_UNIX_LINUX_SOLARIS_OSS by [email protected] Update 6/5/2013 9:40AM UPdate time: 7/31/2013 10:02AM -> 10/17/2013 11:40AM +=============================================================== +TAG content: cygwin, moshell,AMOS, RNC, RBS, mobatch, linux, bash TIPS, solaris , unix 1. COUNTER command pst pgets proxy ( proxy from pst) 2. pst MO pm_of_MO cat 2/raw/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmExtract -u utrance ll "." cat 2/RAW/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmList -m utrancell 3. list all log file on RNC: ftreef /c/logfiles 4. prints the state and configuration of the IP interfaces stir 5. stip 6. Check number of cells in each RNC module lkr 7. tip on pmr command pmr -r 7-10 -l 2/rcpd01/110308_100929/RCPD01_ropfiles.zip -s 20110307.1400 -e 20 110307.1700 pmr -r 7-10 -s 20110309.1200 -e 20110309.1800 8. How to fetch log for a duration time lgtaom -l 2/rcpd01/20110310_102758/RCPD01_logfiles.zip -s 2011-03-09.1200 -e 201 1-03-09-17.1700 9. print cell data for all cells belonging to IubLink=Iub_304 ced -r iub_304 --> print cell data for all cells belonging to IubLink=Iub_ 304 10. Check board load C:\WORKING\3G\VTL RAN 3G\10 - Trick\capi.TXT or by pmr 11. How to use tesummary, output html file ./decoder/teSummary.pl -file 5/110308_101656/teread.log -html 5/110308_101656/te read.html
23

202546177-Mos-Hell (1) com

Nov 20, 2015

Download

Documents

elesey424

moshell commands
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
  • +===========================================================HELP FULL COMMAND FOR MOSHELL_CPP_CYGWIN_UNIX_LINUX_SOLARIS_OSS by [email protected] 6/5/2013 9:40AMUPdate time: 7/31/2013 10:02AM -> 10/17/2013 11:40AM

    +===============================================================+TAG content: cygwin, moshell,AMOS, RNC, RBS, mobatch, linux, bash TIPS, solaris, unix

    1. COUNTER commandpstpgets proxy ( proxy from pst)

    2. pst MO pm_of_MOcat 2/raw/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmExtract -u utrancell "."

    cat 2/RAW/A20110115.0945-1000.1.xml | /home/ephucle/moshell/pmList -m utrancell

    3. list all log file on RNC:ftreef /c/logfiles

    4. prints the state and configuration of the IP interfacesstir

    5. stip

    6. Check number of cells in each RNC modulelkr

    7. tip on pmr command

    pmr -r 7-10 -l 2/rcpd01/110308_100929/RCPD01_ropfiles.zip -s 20110307.1400 -e 20110307.1700pmr -r 7-10 -s 20110309.1200 -e 20110309.1800

    8. How to fetch log for a duration timelgtaom -l 2/rcpd01/20110310_102758/RCPD01_logfiles.zip -s 2011-03-09.1200 -e 2011-03-09-17.1700

    9. print cell data for all cells belonging to IubLink=Iub_304 ced -r iub_304 --> print cell data for all cells belonging to IubLink=Iub_304

    10. Check board load

    C:\WORKING\3G\VTL RAN 3G\10 - Trick\capi.TXT or by pmr

    11. How to use tesummary, output html file

    ./decoder/teSummary.pl -file 5/110308_101656/teread.log -html 5/110308_101656/teread.html

  • 12. How to count No. of file in folder

    ls -l | wc

    13. flowfox follow time

    ./decoder/flowfox.pl --file ./decoder/log/cd3.txt --start 11:03:00.000 --end 11:04:50.000 -o ./decoder/log/cd3_flowfox_2.html --imsi 452048800046217

    Processing ./decoder/log/cd3.txt: Log start timestamp: 11:03:00.000 Log end timestamp: 11:04:50.000 Flowfox is scanning for timestamp information ... Flowfox is now locating UeRefs for IMSI filter ... IMSI Filter >> (452048800046217): UE refs found () Processing logfile, this may take some time... 0%..........20%..........40%..........60%..........80%..........100% Done!>> Output saved to ./decoder/log/cd3_flowfox_2.html

    14. Checking SCCPAP infor in GPB C2lhsh 000700 rof_sccpAP_infolh ranapmp ueregprint all;arealist cell all;ranap status;ranap conn;ranap dumpRoTable survey;ranap dumpRoTable;rncss_ranap;rnsap status;rnsap conn;rnsap dumpRoTable survey;rnsap dumpRoTable;rncss_rnsap;lcs; ranap status 0;ranap cong -froid 0; ranap status 1;ranap cong -froid 1; rnsap status 0;rnsap cong -froid 0; rnsap status 1;rnsap cong -froid 1; rnsap status 2;rnsap cong -froid 2;

    15. How to parse MOM-moshell offline-parsemom /home/ephucle/moshell/jarxml/RNC_NODE_MODEL_K_9_115_COMPLETE.xml

    16. How to read counterpmx -l RCPD26_ropfiles.zip . pmNoSysRelSpeechUlSynch

    17. How to read formula

    OFFLINE_RCPD26_DCG_K> l cat /home/ephucle/moshell/commonjars/pm/FORMULA_RNC_K_1_0.txt | grep SHOFailContrib

    18. Check UE in iublink

    uer -r Iub_IHN589

    19. How to remodule for nodeBset Iub_IHN589 atmUserPlaneTermSubrackRef

    20. How to check traffic in nodebuer -m 8

    21. How to Ping CP & UP of RNSAP/RANAP ipac_traceroute -z .. -d..ipac_ping -z .. -d..UP ping: facc IpAccessHostEt_sourceRNC ping IpAccessHostEt_destRNC

  • CP Ping: GURO02_ERNC06> ipac_ping -z IpAccessHostGpb_ipAddress1/2 -d IpAccessHostGpb_ipAddress1/2

    22. Ethernet mode setting for RNC OAMethernet mode configethmode

    23. check ip connection:stip

    24. check ranap status:lhsh 000700 ranap statussccadm_info all

    25. How to test RANAP

    lh ranapmp ranap enable 1lh ranapmp te e bus_receive bus_send rnhRanapRouterClh ranapmp fte sRCPD32> lh ranapmp fte s

    110428-09:52:01 10.59.240.249 8.0s RNC_NODE_MODEL_L_1_119 stopfile=/tmp/11036

    Position Board Process Status AddedTraceConditions0007 GPB65 RNC_EXCEPTION enabled trace10007 GPB65 UEH_EXCEPTION enabled trace10022 GPB65 RNC_EXCEPTION enabled trace10022 GPB65 UEH_EXCEPTION enabled trace10022 GPB65 rnhRanapRouterC enabled bus_send bus_receivemon ranapmpu+del ranap_sgu-run

    and then turn on tracel /home/ephucle/moshell/monitor6054 10.59.240.249 33079 | ./decoder.pl --w10b | tee ./log/ranap_reset.log | ./flow.pl -colour

    26. cell trace, know cell id

    lh mod uerandtrace on -cell 9016

    27. remove file in cygwin:rm

    28. How to decode ctr.bin fileunzip:gzip -d ./2/rcpd10/CTR/*.gzdecode:

    you have to pipe the output to "decoder.pl --extern" in order to decode the embedded signalling messages such as NAS,etc--gpeh: for ctr and gpeh

  • --extern for view NAS message./decoder/decoder.pl --p71 --gpeh ./2/rcpd10/ctr/*.bin | ./decoder/flow.pl -colour | tee ./2/rcpd10/ctr/ctr_decoded.txt

    29. How to use zpm tool to decode dump log on CPP node

    l zpm error 2/rcnh06/110610_174755/20110610_102249_c_pmd_90_000500_0xbea00015.pmd -o 2/rcnh06/110610_174755/0xbea00015_decoded.txt

    30. How to turn on and turn off UE trace:off:lh mod ueidtrace off -ue -all (default)lh mod ueidtrace off -ue -all ; uerandtrace off -cell -all

    #Check status ongoing selective or random UE traceslh mod uerandtrace status ; ueidtrace status

    lhsh 000600 uerandtrace status (check for random trace)

    turn on on:lh mod ueidtrace on -ue imsi $imsiVar

    31. How set struct by MO script, ex

    SET( mo "ManagedElement=1,RncFunction=1,IurLink=742" exception none userPlaneTransportOption Struct nrOfElements 2 atm Integer 0 ipv4 Integer 1)

    32. How to check data of modulelh mod22 drh_dcrh_topdata all lh mod22 drh_ccrh_topdata all

    33. How to do eteloopback test for E1?

    23251 1 (ENABLED) AtmPort=MS-15-3,VplTp=vp13,VpcTp=1,VclTp=vc139023252 1 (ENABLED) AtmPort=MS-15-3,VplTp=vp13,VpcTp=1,VclTp=vc1391acc 23251 23252 eteloopback

    34. Check MO status after load DT.st all 1.*0st all 0.*1

    35. DCGM location folder for AMOS in OSSvar/opt/ericsson/amos/moshell_logfiles

    36.st cell 1.*0st cell 0.*1

    37. How check cell data

    lh mod60 celldata -c 16011

  • 110716-14:55:17 10.59.240.1 8.0h RNC_NODE_MODEL_K_9_115_COMPLETE stopfile=/tmp/4844=============================================================================================$ lhsh 000600 celldata -c 160110006: ------------------------------------------------------0006: cId: 160110006: cellFroId: 4000006: RO instance: 1090006: RNC Module: 00006: IubLink froId: 890006: CC SP: 001800/sp0.lnh/CommonChMainPT0006: Total ASE DL: 2.960006: aseDlAdm: 5000006: Total ASE UL: 2.59

    38. How to check ntp server synchronization in nodeB

    $ ntp peerinfoNTP Info remote refid strat flags when poll reach delay offset disp (sec) (sec) (sec) ==========================================================================================x 10.50.26.2 0.0.0.0 16 1 0 1024 0 0.00 0.000 0.00x 10.50.26.1 0.0.0.0 16 1 0 1024 0 0.00 0.000 0.00x : Reject # : Falsetick ^ : Excess - : Outlyer + : Candidate s : Selected * : Sys.peer o : Prosp.Peer

    39. Checking mspg for ETMF4hget mspg selectedBoard|selectedPort

    40. pmx check rssi value of rbs pmx carrier -m 24 -a pmxh sl2056 pmNoRrcConnReqBlockNodeCs|pmNoRrcConnReqBlockNodePs|pmNoRejRrcConnMpLoadC|pmTotNoUtranRejRrcConnReq|pmNoRrcReqDeniedAdm|pmNoRrcPsReqDeniedAdm|pmNoRrcCsReqDeniedAdm -m 8 41. check the speed of the fan in RBS6000

    The trace to check the speed of the fan in the RBS6000 te e all supSysCtrlClimate search for setfan in the temp traces OR ter | grep -i setfan

    ==================================42. TIPS checking when intergrationa. in most cases, we can check: alt, utrancell locked or unlocked, cellreserved,

  • lk, eteloopback etc. b. check KPI: pmr s 20110809.0100 e 20110809.0200 c. check CS, PS performance: pmxh cell.*0001 pmTotNoRrcConnectReq$|pmTotNoRrcConnectReqSuccess -m 5 pmxh cell.*0001 pmTotNoRrcConnectReqPs|pmTotNoRrcConnectReqPsSucc -m 5 pmxh cell.*0001 pmTotNoRrcConnectReqCs|pmTotNoRrcConnectReqCsSucc m 5 d. check uplink interfere: RBS: pmr r 1 e. check utrancell power related: RNC: get utrancell.*52511C1 maximumTransmissionPower Get utrancell.*52511C1 primaryCpichPower RBS: get . maxTotalOutputPower f. If customer told you check RBS output power, you can use: RBS: pmr r 1 g. check VSWR: lh rru fui get vswr h. check transmission quality: pget e1 i. restart rru j. restart DU =====================================

    43. truni: By default, the command trun file halts when a command fails.truni: ignore exceptions, the execution does not halt when a command fails.OFFLINE> h truni***************************************************************************************trun[is1cr] |***************************************************************************************It is also possible to specify a file located on a web server (eg. when the script is located on the CPP node).See examples below. For more info, refer to MoTester documentation on http://utran01.au.ao.ericsson.se/moshell/training/references/cpp/runMoTester.html .Options: - i: ignore exceptions, the execution does not halt when a command fails. - s: simulated run, the command file execution is simulated, no commands are actually executed on the node. Can be used to verify the syntax of a script prior to running it for real. The simulated mode is always used in "offline mode" or "simulated undo mode", regardless of the "trun" options.

  • - 1: executes the whole script in one transaction, then prompts for confirm or rollback. This option should be used with great care and only when absolutely necessary (e.g. when changing IP address of the node, see example script in moshell/examples/misc/ip_change.mo). In regular usage, it is recommended to not use this option as it has been observed to cause database corruptions in certain cases. - c: used in combination with option "1" above, will avoid the prompt by automatically confirming the transaction - r: used in combination with option "1" above, will avoid the prompt by automatically rolling back the transaction

    44. dump online-list dumpdump list -adump error -i /c/pmd/37/001600/0xfdf59d9f.pmd

    45. Checking sleeping cell issue (Using RRC) KG5071C | YGIN07_ERNC10 | pmxh -m 1 UtranCell=YI07_10_.*_KG5071 pmTotNoRrcConnectReq$|pmTotNoRrcConnectReqSuccess|pmCellDowntimeAuto|pmCellDowntimeMan 46.SGSN in Pool (iuflex)if you can define a lot of ranap mo mean that you have enable iuflex and NRI(for PS) in rncfunction=1 mo is greater than 0. I have configure SGSN inpool for RNC3820 with ericsson SGSN. In my opinion, you can check the addtibute "cnId" in ranapmo. it is correct of not. by the way, you should also double check the attibute "destPointCode" in Mtp3bSrs" mo. The last thing yuo can do is put some trace on RANAP_ASN, use action "setAutoActivate", "setAutoDown" of m3ua mo and see the message go forth and back between RNC and SGSN. 47. wireshark filterranap.gTP_TEI == 0x00008a2bgtp.teid == 0x00008a2b

    48. Display state, user, and bandwidth usage for ATM ports and channels.stvbstv[b][r] [] []***************************************************************************************Display state, user, and bandwidth usage for ATM ports and channels.

    49. How to Restart scc_server in SCCP MP

    lh sccpmp sma -all | grep scc # find the CXP number of the scc_server Load Moduleacc Program=CXC.._R.. restarty

    50. How to Show node on OSSexample: pwAdmin -l | grep rnc | 91. List node from OSS : more /etc/hosts 51. Sync trace RBShttps://cc-jira.rnd.ki.sw.ericsson.se/jira/browse/CPP-1307

  • Trace settings: ------------------- te enable trace1 trace8 trace9 Nss_tuRegMp_proc

    COLI commands: ----------------------- nssinfo clk nssinfo fls nssinfo osc

    52. How to do SW allocation by moshellset . autoconfigurationallow truepr swallocationacc MO deleteslotacc MO addslot

    53.How to setting Ethernetmode for APP port>lssfpconfCard Port X SFP mgmt SFP type PHY mode Module Linkprop10GbE A 18 autconf nc limiting nc YES10GbE B 28 autconf nc limiting nc YES10GbE C 32 autconf unknown limiting NOK YES10GbE D 42 autconf unknown limiting NOK YES

    >setmode 32 1gforcedCommand setmode executed for card on slot: 3, channel: 1Mode for port setOK>setmode 42 1gforcedCommand setmode executed for card on slot: 3, channel: 2Mode for port setOK>lssfpconfCard Port X SFP mgmt SFP type PHY mode Module Linkprop10GbE A 18 autconf nc limiting nc YES10GbE B 28 autconf nc limiting nc YES10GbE C 32 autconf unknown 1gforced NOK YES10GbE D 42 autconf unknown 1gforced NOK YESCommand lssfpconf executedOK

    53. license intergration unlock test status

    license iu status

    55. How to Ping to test sigtranipac_traceroute -z -d

    54. How to check CPU load for aboard

    $ lhsh 000800 lcs0008: Load Control Statistics

    55. Command to activate trace

    lh mod ueidtrace on -ue imsi 452022114994487lh mod uerandtrace on -cell 65000lh mod te e bus_send bus_receive UE_ASN_RRClh mod te e bus_send bus_receive UE_ASN_RANAP

  • lh mod te e bus_send bus_receive UE_ASN_RNSAPlh mod te e bus_send bus_receive UE_ASN_NBAP//lh mod uerandtrace max 100//lh mod te e trace4 UE_GENERAL //lh mod te e trace1 UEH_EXCEPTION//lh mod te e trace3 IU_IF

    //lh mod ueidtrace off -ue -all

    //trace on DC device

    lh dc2021 te e all IUC_CONTROL_UL_UElh dc2021 te e all IUC_CONTROL_DL_UE//lh dcxx te enable trace3 trace5 DISCARD_UE//lh dcxx te enable all SP_EXCEPTIONlh mod te e trace3 IU_IF

    56. How to collect counter

    pmxk -m 4 UtranCell=HC13961 pmNoSystemRabReleasePacket$

    57. How to restart aboard on RNC

    OFFLINE> h progkill

    ***************************************************************************************proglist/progkill [-e] [] [|]***************************************************************************************List or restart programs on boards or board groups.

    These two commands are wrappers for the COLI commands pglist/pm_pginfo and pgkill/pm_kill.

    The proglist command lists the OSE programs running on MP, BP, or SP processor. The program handle, state, program number and name are shown.With option "-e", the heap and pool size are also shown. It is also possible to add a filter after the "-e" option in order to show other program settings apart from the heap and pool. Eg: "proglist -e stack" shows all program settings matching the word "stack".A list of all available program settings is shown at the end of the printout (when option "-e" is used).

    The progkill command is used for restarting an individual program on a MP. If this command is used on a BP or SP then the whole processor restarts. A string which matches the program number or program name must be given as argument to the command. Eg: "progkill jvm", or "progkill 0784"

    Examples: - List programs on central MP:>> proglist - List programs on board 001400, whose product number match "0787">> lhsh 001400 proglist | grep 0787 - List programs on all MP/BP/SP processors together with heap and pool info>> lh all proglist -e - Show the stack size for all programs running in the O&M MPs>> lh ommp proglist -e stack_size$ - List programs on all boards of the boardgroup "mp", whose name match "system"

  • >> lh mp proglist | grep system - Restart the program whose product number matches "2417" on board 001400>> lhsh 001400 progkill 2417 - Restart the programs whose name matches "aal2ap" on all boards of the boardgroup "mp">> lh mp progkill aal2ap

    58. How to extract mobatch log result

    example: extract finger print of nodeB from mobatch logsgrep -i "finger" *.log

    59. How to run GUI on nodeB by command

    a. download bemcli.jar by moshell

    htget http://rbsIp/em/bemcli.jar

    b. run from OSSjava -jar bemcli.jar 10.244.2.39 help

    Usage:BEM on the command line connects to the specified RBS and executes the commands as described below.

    help

    Displayes this help.

    cabinet

    Runs Cabinet Equipment Wizard with specified xml file.

    .......

    Sample:

    java -jar bemcli.jar 10.0.0.1 cabinet my_cabinet_xmlfile.xml -rbs_prop /user/bem/RBS_EM.properties 60. How to format nodeB + and load basic package for nodeB1) reload -- this will enter backup mode2) mount_c2 this will mount /c2 drive3) formathd /d this will format the /d drive4) formathd /c2 this will format the /c2 drive5) reload -- to initialize the disk6) ifconfig le0 IP netmask to set the ip address and subnetmask7) reload refresh the Node-B

    61) How to trace to find out what counter increase when CS call drop

    lh mod te e trace3 IU_IF

    example trace log:IU_IF) ../src/UehPmEventDataD.cpp:1394 TRACE3:Increment counter ROAM_UTRANCELL_P

  • MNOSYSTEMRABRELEASEPACKET; for Source Best Cell on observed instance Id=380; numOfSteps=1; cellId=50186; cellFroId=380; sRncUeRef=1006; sRnti=66542; IMSI = 270011008275182; connType = uehPacketCch.(IU_IF) ../src/UehUeCtxtC.cpp:1362 TRACE1:Sending IuReleaseRequest for packet switched CN with cause 16; UeRef = 4940; IMSI = 270011006155400; cellId = 50178; cellFroId = 308; S-RNTI = 70476; connType = uehSp64, globalCnId: mcc = 270, mnc = 1, mncLength = 2; cnId = -1 (User Inactivity)

    62. How to restart GPB C1 by telnet/serial commandUsing the serial port, restart the Core MP using the following command

    $ restartObj meIf the restart command does not trigger a restart of the Core MP, reload the Core MP using the following command

    $ reload

    63. ranap conn usage

    RSG081E> lhsh 000700 ranap conn usage

    120829-16:45:05 10.20.130.60 9.0a RNC_NODE_MODEL_K_9_115 stopfile=/tmp/7468$ lhsh 000700 ranap conn usage

    Print information from RANAP connection table.

    Usage: ranap connPrints the first n connections in the table, for all froIds.

    Usage: ranap conn Prints the first n connections for a specific froId.

    Usage: ranap conn -option1 -option2 -option3 ...Advanced search in RANAP table. Available Options are: -froid // only show conns for one froId -sccpstate // only show some sccp states -uectxtstate // only show some uectxt states (as perceived from ranap) -ueref // only show for one ueref # -moduleid // only show for uerefs on one module mp or Mbms -domain |cs|ps // only show for one domain range for is 0(cs) to 1(ps) -iusignconnid // only show for one iu signalling connection -from // start looking from sccp conn id -limit // only show first hits -to // stop looking at sccp conn id

    Available states are: conn, notconn, notconn_msg, inpend, outpend

    Example: ranap conn -froid 1 -moduleid 12 -sccpstate conn -uectxtstate inpend outpend

    $

    64. check allocated status of nodeBstdrlhsh 000700 drhcendh dc

  • 65. catch IU CS userplane message bylh dc80 te e bus_send bus_receive IUC_CONTROL_UL_UElh dc80 te e bus_send bus_receive IUC_CONTROL_DL_UE

    66. Trace in IMSI/CELL

    //lh modxx uerandtrace -cell -all //lh modxx uerandtrace max -unlim

    lh mod ueidtrace -ue imsi 452010801018644//lh mod uerandtrace on -cell 34058 //if want to trace on CELL turn on this//lh mod uerandtrace on -cell 34059

    lh mod te e bus_send bus_receive UE_ASN_RRClh mod te e bus_send bus_receive UE_ASN_RANAPlh mod te e bus_send bus_receive UE_ASN_RNSAPlh mod te e bus_send bus_receive UE_ASN_NBAP

    lh mod te e trace1 UEH_EXCEPTIONlh mod te e trace4 UE_GENERALlh mod te e trace1 trace3 IU_IF

    //lhsh te eall UE_IRAT_HANDOVER//lhsh te e all UE_IRAT_CELL_CHANGE

    //lh ranapmp te e trace3 Scc_server_proc //Trace on SCCP

    mon modl $moncommand | decoder/decoder.pl --p71 | tee trace/PSHO/E_N2.log | decoder/flow.pl -colour | tee trace/PSHO/E_N2_flow.log

    ==============

    trace SHOlhsh te e bus_send bus_receive UE_ASN_RRClhsh te e bus_send bus_receive UE_ASN_RANAPlhsh te e bus_send bus_receive UE_ASN_RNSAPlhsh te e trace4 trace6 trace 7 UE_GENERAL

    #[2012-06-19 01:35:00.632] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5529 TRACE6:Signal spConfigReq sent to port dcsIfControlP#[2012-06-19 01:35:00.632] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5530 TRACE7:DcsSpConfigReqD{dcRhRef 24 76 101 128 48 0 3 30 236 0 0 0 0 0 128 49 0 0 0 0 12 0 0 0 1,ueRef -1,ueModuleId -1,mpBagBufPtr 1671050592,bagSize 0}#[2012-06-19 01:35:00.636] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5452 TRACE6:uehProcedures[ueRef 7916]: signal spConfigCfm received on port dcsIfControlP in state WaitSpConfigRsp#[2012-06-19 01:35:00.636] 012100/RncLmUePT(UE_HANDOVER) ../src/UehSoftHoC.cpp:5452 TRACE7:uehProcedures[ueRef 7916]: signal data: DcsIfControlUeRefD{ueRef 7916,ueModuleId 12}lhsh te e trace1 trace6 trace7 UE_HANDOVER

    #012100/RncLmUePT(UE_HANDOVER_AS) ../src/UehSoftHoC.cpp:1878 TRACE3:Intra Soft RNC Radio Link Set Addition#012100/RncLmUePT(UE_HANDOVER_AS) ../src/UehSoftHoC.cpp:803 TRACE3:Event e1a received with ScrCode = 306 for UeRef =

  • lhsh te e trace3 UE_HANDOVER_AS

    lhsh te e trace1 trace3 UEH_EXCEPTIONlh te e all SP_EXCEPTIONlh te e trace1 trace5 HANDOVER_EVAL_UElh te e bus_send bus_receive RRC_UL_UE # to trace the Measurement Report

    te e trace3 UE_COUNTERS_GSM_RELATIONRncLmUePT(UE_COUNTERS_GSM_RELATION) ../src/UehPmEventDataD.cpp:747 TRACE3:Counter ROAM_GSMRELATION_PMNOOUTIRATCCSUCCESSHS; not incremented for Target Gsm Cell Relation as adjcentCellGsmRelationCellFroId is not valid, block=UehUeCtxtC; sRncUeRef=n; sRnti=n; numOfSteps=1; gsmCellId=1; gsmCellFroId=-1; adjcentCellGsmRelationCellFroId=-1; procedureIndicator=UehProcIndIRATCellChange;

    flowflox online toolhttp://utran01.epa.ericsson.se/flowfox/live.php

    BO checkhttp://10.19.208.21:8080/InfoViewApp/logon.jsp

    cach chuyen tu ueh log sang html te summary log

    l ./decoder/teSummary.pl -f temp/RSGTB1E_EXCEPTION_121109_1133.log -html temp/RSGTB1E_EXCEPTION_121109_1133.html

    67. paging counterutrancel::pmNoPagingType1Attempt UtranCell::pmNoPagingAttemptUtranRejected Paging::noOfPagingRecordTransm

    68. How to download COMPLETE MOM online

    getmom RNC_NODE_MODEL_K_9_115_COMPLETE.xml

    69. How to seach event id in measument report ( RRC)search "evID"

    70. Path to CTR trace log in OSS/var/opt/ericsson/nms_umts_pms_seg/segment1/CTR/SubNetwork=RSG011E/MeContext=RSG011E

    !Check current MSC on UE! *789# !Connect to node from OSS! eaw NE=MSHC01E

  • !Convert MSISDN -> IMSI! mgtrp:msisdn=84936390077; !Check location! Mgssp:imsi=; 71. AMOS folder/opt/ericsson/amos/moshell/monitor6054

    72. How to trace and decode by AMOS

    l $moncommand | /opt/ericsson/amos/decoder/decoder.pl --w12b | /opt/ericsson/amos/decoder/flow.pl -colour | tee /home/ericsson/hoang/emlpp_1.txt

    72. AWK[~]$ cat ./temp/9_ueh_read/ueh_rsg101e_1453.txt | grep "ExceptionCode = " |$ grep UehRncHardHandoverC|awk 'BEGIN{FS="ExceptionCode = "}{print $2}' | awk 'BEGIN{FS=";"}{print $1}' | sort | uniq -c 14 409 187 509

    ex2:[/cygdrive/c/working/CSR/2289506, Abnormal Dropped Call from ERA to NSN/log]$ cat RSGTB1E_130611_1638_UEH.log | grep -i "causecode = rnsaprequested_configuration_not_supported" | awk 'BEGIN {FS=";sourceConnType ="} {print $2}' | awk 'BEGIN {FS="; "}{print $1}' | sort | uniq -c 6 uehPacket128 17 uehPacket12864 62 uehPacket128Hs 131 uehPacket384Hs 91 uehPacket64 239 uehPacket64Hs 1382 uehPacketEulHs 8 uehPsInt1616 104 uehPsInt1664 93 uehPsInt16Hs 1 uehPsInt6416 215 uehRrcConn 367 uehSp0 4 uehSp12864 2 uehSp384Hs 12 uehSp64 6 uehSp64Hs 1 uehSpeech 9 uehSpeechAmrNbMMPsInt16Hs 2 uehSpeechPsInt128Hs

    http://vi.wikipedia.org/wiki/AWK #print file by

    73. perlhttp://www.slideshare.net/davorg/introduction-to-perl-day-1how to call perl script from cygwin:add line: #!/usr/bin/perl -w vao dau script

  • call script by: filename ( trong cygwin)

    74. egrep "MOs to grou" *.log

    75. Reallocate all iublink resources evenly in the noderesub iublink=

    76. find out negative counterpmxs

    77. change excuting right in solarisericsson@vmshcxts01> chmod -R 777 /home/ericsson/hoang/rnchc

    78. new read counter from ropfile

    pmextract

    79. quickly check license by inv commandinvl

    80. Check state for all sites located on a specific module

    RNC02> str -m 13

    Check state for all sites located in a specific subrack

    RNC02> str -s ms

    Check state for all sites that use a specific transmission type

    (A=ATM, I=IP, AI=DualStack)

    RNC02> str -t ai

    81. check with ced that there are no cells handled by a CC device belonging to a different module: the list is empty => Ok!

    RNC143> cedr | grep !

    82. Printing usage for all cells of a moduleRNC99> ced -m 1rnc22> lh mod celldata -m

    Printing usage for one RBSRNC66> cedh -r iub_rbs54

    83. uer advanced:

    Print all calls, but without showing the PDR device (saves time)uerp

    Print only the summary tables, not the individual callsRNC11> uers

    Print all drift contextsRNC99> uerd

  • Printing all variables for a contextRNC10> uer -i 301001800040001 all

    Printing active UE contexts with RRT commands

    RNC12> ueregprint all

    84. Recommended trace objects for UE tracing:

    UE_ASN_RANAP bus_send bus_receiveUE_ASN_RNSAP bus_send bus_receiveUE_ASN_RRC bus_send bus_receiveUE_ASN_NBAP bus_send bus_receiveUE_GENERAL trace4UE_IU_IF trace1 trace3

    85.new tool call drop analysis: flowfilter.pl

    **:ws4264@/net/wl7266/tmp/20090323> ~/decoder/flowfilter.pl -h######################### flowfilter 1.0i, 2009-03-11 #########################

    Tested with flow.pl V2.0, requires IU_IF or UE_IF_UE traces.This tool doesn't work with flow.awk or RAN flow.pl

    Options:

    Default filtering is done on System drops. -ueref Filter by one specific ueref. -debug Debug mode. -help|h Help. -ueh Filter by UEH_Exception code. -rnc Filter by RNC_Exception code.(Not tested!). -color print in differnt colors. -asn print only drops with asn-traces. -type Filter on one specific type of drop. ROAM_UTRANCELL_PMNOSYSTEMRABRELEASE(SPEECH|PACKET) -file|f read from file. -meas Skipping everything that contain measurement.

    86. RNC UE Context History Buffer

    Purpose: to find out what events led to a UEH exception

    The last 25 events of each call are logged in a buffer, eg RAB transitions, handovers, etc. Up to 500 calls can be logged simultaneously. When a UEH exception occurs that leads to the call being released, the UE context history buffer is printed on bus_send UEH_EXCEPTION.

    It is also possible to print the UE context history buffer of any call via the traces bus_send on UEHISTORY (non selective) or UE_UEHISTORY.

  • In this case, the UE context history buffer must be manually printed to TE log with the command printuehistory.

    More information: 90/190 24-10/FCP 103 6503

    87.ipdatabase from oss for amos /opt/ericsson/amos/moshell/sitefiles/ipdatabase mobatch in amos : /opt/ericsson/amos/moshell/mobatch 88. cygwin package for telnet/ftp/ssh/sftp: NET:inetutils & NET:openssh(follow: http://cygwin.com/ml/cygwin-xfree/2002-04/msg00035.html)

    89. how to create basic package for nodeB

    90. cygwin bash, fast way to change to home folderrun "cd" only

    92. call bash from cmd windowC:\cygwin\bin\mintty.exec:\cygwin\Cygwin.bat

    93. grep & egrep tool of cygwin

    grep LocationArea.*LocationAreaId *.log > ./log1.txtgrep -i iur.*lac ./*.log > ./log3.txt

    egrep -e '^.* LocationArea=.*' *.log > internal.txtegrep -e '^.*ExternalUtranCell=.*' *.log > ExternalUtranCell.txt

    94. ls with colorls -color

    95. command to search in bash cygwinfind / -name make*

    96. login to bash (cygwin from window)@echo offC:chdir C:\cygwin\binbash -l -i

    97. delete many file at the same timerm *.bak

    98. string concatenation is the operation of joining two character strings end-to-end. For example, the concatenation of "snow" and "ball" is "snowball".

    mgw 10.19.206.165 MGHC06E

    99. FIND MSC FROM MSISDN

    login to msc :eaw NE=MSHC04E

  • mgtrp:msisdn=84909027348;mgssp:imsi=452010800626537;mgmap:LAI=452-01-22220; !find RNC location!

    pmxc

    105. call program from perlmy $status = system("vi fred.txt");my $status = system("mobatch .....");

    call perl from other programsystem (perl 1.pl);system (perl 2.pl);

    106. check oss ps -ef | grep -i moshell 107. lsls --color

    108. ghep 2 filecat file1.txt >> file3.txtcat file2.txt >> file3.txt

    oregrep . * >> ./totalfile.txt

    109. rename file/folder in cygwin[~/temp]$ mv 6/ 6_vi

    110. create softlink

  • Creating soft links...ln -s /home/ephucle/decoder/bin/concat_segmented_rlib_traces.pl /home/ephucle/decoder/concat_segmented_rlib_traces.plln -s /home/ephucle/decoder/bin/decoder.pl /home/ephucle/decoder/decoder.plln -s /home/ephucle/decoder/bin/decoder_ss7 /home/ephucle/decoder/decoder_ss7ln -s /home/ephucle/decoder/bin/dropFinder.pl /home/ephucle/decoder/dropFinder.plln -s /home/ephucle/decoder/bin/eventHistoryDatabase.pl /home/ephucle/decoder/eventHistoryDatabase.plln -s /home/ephucle/decoder/bin/flow.pl /home/ephucle/decoder/flow.plln -s /home/ephucle/decoder/bin/flow_ss7 /home/ephucle/decoder/flow_ss7ln -s /home/ephucle/decoder/bin/flowFilter.pl /home/ephucle/decoder/flowFilter.plln -s /home/ephucle/decoder/bin/flowfox.pl /home/ephucle/decoder/flowfox.plln -s /home/ephucle/decoder/bin/historyDecoder.pl /home/ephucle/decoder/historyDecoder.plln -s /home/ephucle/decoder/bin/lgParser.pl /home/ephucle/decoder/lgParser.plln -s /home/ephucle/decoder/bin/msFlow.pl /home/ephucle/decoder/msFlow.plln -s /home/ephucle/decoder/bin/pdr2eth.awk /home/ephucle/decoder/pdr2eth.awkln -s /home/ephucle/decoder/bin/PmEventSpecification_RBS.xml /home/ephucle/decoder/PmEventSpecification_RBS.xmlln -s /home/ephucle/decoder/bin/postprocess.pl /home/ephucle/decoder/postprocess.plln -s /home/ephucle/decoder/bin/ranap_cause_convert.pl /home/ephucle/decoder/ranap_cause_convert.plln -s /home/ephucle/decoder/bin/spEventHistoryDecoder.pl /home/ephucle/decoder/spEventHistoryDecoder.plln -s /home/ephucle/decoder/bin/teSummary.pl /home/ephucle/decoder/teSummary.plln -s /home/ephucle/decoder/bin/uetr2uetrXplorer.awk /home/ephucle/decoder/uetr2uetrXplorer.awk

    ln--help for help

    111. mom[abcdfloprtux] [] [] [] [] []112. !!! Please refer to README chap 3.3 (or "h syntax") for more info on how to set values for each specific attribute type (eg Struct, array of MoRef, array of Struct, etc).113. draw webpmxw utrancell=iub-6-1 pmTotNoRrcConnectReq$ -m 20

    114. pstool list

    115. ceds, cedg: cell data

    ceds: state and supported features of each UtranCell. Read from MO data on UtranCell and children.

    cedg: state and geographical coordinates of each UtranCell. Read from MO data on UtranCell and children.feed into http://maps.google.com/maps?q=

    -------------------------------------------------------------------------------------------------------------------------------------------- Mod UtranCell CFRPHEMU Antenna and Cell Coordinates, feed into http://maps.google.com/maps?q=-------------------------------------------------------------------------------------------------------------------------------------------- 21 CTU20847 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2424,-73.140621 41.2157,-73.149569 41.1996,-73.179159 41.2016,-73.215508

  • 21 CTU20848 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2016,-73.215508 41.2208,-73.241665 41.2482,-73.245378 41.2710,-73.224885 21 CTU20849 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2710,-73.224885 41.2785,-73.189759 41.2672,-73.156478 41.2424,-73.140621 21 CTV20841 111111-- 41.2383,-73.1937 41.2383,-73.193665 41.2424,-73.140621 41.2157,-73.149569 41.1996,-73.179159 41.2016,-73.215508

    116. lh mod procload: check load cause by trace

    117. pset (uetr& gpeh)

    118, upgrade amos

    put moshell. zip to /tmpcd /tmpunzip moshell.zipbash moshell_install -a

    119. Print all drift contexts for softhandoveruerd

    120.A random UE trace for any single UE in the whole node

    RNC26> lh mod uerandtrace on -cell -all;uerandtrace max 1

    flowlog: see detail mesasge in flow

    121. how to read file (with update status from OSS/linux)tail -1000f neadStatus.log.yin

    122. use tip for clear the screen in script#print "\033[2J";#clear screen#print "\033[0;0H"; #jump to 0,0

    123. awk advance

    print all text fileawk '{print}' ./content.txt or awk '{print $0}' ./content.txt print frist colume of each lineawk '{print $2}' ./content.txt

    124. rnc restart command, coli, or telnet moderestartObj me coldwtestrestartObj me coldrestartObj me warm"

    125.how to use concat tool in decoder cat ./RSGBT1E_Cipher_0636_310713.log | ~/decoder/concat_segmented_rlib_traces.pl | tee ./RSGBT1E_Cipher_0636_310713__concat.txt

    126. selection file\var\opt\ericsson\nms_smo_srv\smo_file_store\Selection

  • 127.

    cwdcmd echo -n "^[]0;${user}@${HOST}:${cwd}^G"ipf cd /etc/opt/ericsson/nms_cif_ist/ipfist_run /opt/ericsson/sck/bin/ist_runistdata cd /var/opt/ericsson/nms_cif_ist/dataistlog cd /var/opt/ericsson/nms_cif_ist/logll ls -alllr ls -altrsck cd /opt/ericsson/sck/binsmtool /opt/ericsson/nms_cif_sm/bin/smtoolypmake (cd /var/yp;make)

    128.The longitude of the sector.If X = longitude in degrees (-180 to 180), the value is calculated by inserting X into the following formula:(X/360) 16777216The latitude of the sector.If X = latitude in degrees (0 to 90), the value is calculated by inserting X into the following formula:(X/90) 8388608http://www.gpsvisualizer.com/map_input?form=googleearth

    cedg: state and geographical coordinates of each UtranCell. Read from MO data on UtranCell and children.feed into http://maps.google.com/maps?q=

    129. command to check MP loadlhsh 000500 capi tot

    lhsh 000500 capi prio

    lhsh 000500 capi type pri **

    lhsh 000500 capi core all

    lhsh 000500 capi peak

    lhsh 000500 pm_scanner_status

    lhsh 000500 te log read

    130. vswrlh ru fui get vswr

    130. how to check call drop for a cellMonitor Speech DropRBTPT1E> pmxh utrancell.*ldda24 pmNoSystemRabReleaseSpeech|pmNoNormalRabReleaseSpeechpmNoNormalRabReleaseSpeech: normalpmNoSystemRabReleaseSpeech: abnormal (drop)

    SpchDrop = 100 * pmNoSystemRabReleaseSpeech / (pmNoNormalRabReleaseSpeech + p

  • mNoSystemRabReleaseSpeech)SpchCCSR = SpchAccess * (100 - SpchDrop) / 100

    Monitor HS DROPHsDrop = 100 * (pmNoSystemRbReleaseHs) / (pmNoSystemRbReleaseHs + pmNoNormalRbReleaseHs + pmNoSuccRbReconfOrigPsIntDch + pmPsIntHsToFachSucc)NoHsRel = pmNoSystemRbReleaseHs + pmNoNormalRbReleaseHsNoAbnormalHsRel = pmNoSystemRbReleaseHs + 0

    how monitor CS+HS counter at them same timepmxh utrancell.*ldda24 pmNoSystemRabReleaseSpeech|pmNoNormalRabReleaseSpeech|pmNoSystemRbReleaseHs|pmNoNormalRbReleaseHs -m 0.5pmr -m 0.5 -r 12,16 | grep -i ldda24

    Monitor RRCpmTotNoRrcConnectReq @ MO Class: [UtranCell]pmTotNoRrcConnectReqSuccess @ MO Class: [UtranCell]

    UtranCell=5HN8611 pmTotNoRrcConnectReqCsUtranCell=5HN8611 pmTotNoRrcConnectReqCsSucc

    RRC Connection Request rejected due to Admission ControlUtranCell=5HN8611 pmNoRrcReqDeniedAdm

    RAB HSDPApmNoRabEstablishAttemptPacketInteractiveHs MO Class: [UtranCell]pmNoRabEstablishSuccessPacketInteractiveHs MO Class: [UtranCell]

    132. RNC LAB/CPP LABhttps://wcdma-iov.rnd.ki.sw.ericsson.se/cgi-bin/nodeInfo.pl

    133. telnet restart command:reload (warm)restartObj me coldwtestrestartObj me warm

    134. cell tracelhsh 010800 uerandtrace on -cell cid xlhsh 010800 uerandtrace max 5lhsh 010800 te e bus_send bus_receive UE_ASN_RRClhsh 010800 te e bus_send bus_receive UE_ASN_NBAPlhsh 010800 te e all UEH_EXCEPTION

    lhsh 010800 te e all ADMISSIONlhsh 010800 te e all ADMISSION_CELLlhsh 010800 te e all ADMISSION_REJECT_CELL

    lhsh 010800 te e trace6 trace7 trace3 trace1 CONGESTION_CELLlhsh 010800 te e trace6 trace7 trace3 trace1 SOFT_CONGESTION_CELL

    lhsh 010800 te e bus_send bus_receive UE_NBAP_RL_HANDLINGlhsh 010800 te e all RADIOLINK_REJECT

    135. UEH web page - common Exception handlerhttps://wcdma-commonexception.rnd.ki.sw.ericsson.se/pages/exceptions.jsp

    136. COMPLETE MOMparsemom /home/ephucle/moshell/jarxml/RNC_NODE_MODEL_N_1_410_COMPLETE.xml

  • 137. set_check#==============================================================================

    # Consistency check on the Set command

    # * 0 = no parameter consistency check is done before performing a set operation

    # * 1 = Prints an extra warning on the set command when trying to set an attribute to a value different to the recommended value

    # * 2 = Same as 1, and an exception is given when trying to set an Ericsson Internal parameter to a value different than the recommended value. The list of Ericsson Internal parameters can be printed from the complete MOM with command "momd . . . ericsson"

    # The recommended values are stored in the files moshell/commonjars/pm/PARAM* and depend on the node type and SW release

    # Additional recommended values can be stored in the file specified in the uservariable custom_param_file

    #==============================================================================

    138 exeption toolhttp://utran01.au.ao.ericsson.se/utranwiki/ToolsInformation/UsefulScriptsAndHacks#exceptiontoolshttp://newtran01.au.ao.ericsson.se/~econkel/tools/

    139. How to use Flowfoxcat ./RSG011E_130906_0115_cipher_d.txt | ~/decoder/decoder.pl --w12b | ~/decoder/flowfox.pl | tee ./RSG011E_130906_0115_cipher_followfox.html

    140. dbc: cannot run in amosdownload CV by cvget and database check by: dbc |

    141. dBm to W (http://www.rapidtables.com/convert/power/dBm_to_Watt.htm): Pw=1/1000* 10^(Pdbm/10)

    142. pmr & pmx commandpmr -m 7 -r 12-16 | grep -i 'ldda24\|ldbl11' ==> cannot run yetpmr -s 20131016.0145 -e 20131016.0300 -r 14-22,37-41,71 | grep -i ptpt39pmxh -s 20131016.0145 -e 20131016.0300 utrancell.*ptpt39 pmNoSystemRabReleaseSpeech|pmNoNormalRabReleaseSpeech

    143. Find IP of all node in OSS:/opt/ericsson/ddc/util/bin/listme

    144. all the processes running on OSS system: ps elfprstat: same ps but continually updates the display of information on your screenvmstat provides a convenient summary of system activity as well

    145. C windowns drive path: /cygdrive/c/