Kitsnet
Multi-port Flow Selector Valve
6 inlet ports 2 8 inlet ports 4
16 inlet ports 2 10 inlet ports 3
7/29/2019 20111109181038317
2/14
Page 2 of 14
Introduction
The Multi-port Flow Selector Valve (MSV) is a kind of special equipment
which is used in the metering station of oilfields for the purpose of metering of
oil well fluid. Instead of the complicated conventional /existing manifold and
powered T valves group, it can be more simply operated for well-selection
and metering with local control or remote control mode. It also can be easily
operated with hand wheel for well-selection and metering on site too.
Capability & FunctionSimple structure, small size, compact design, easy to install and operate
Little maintenance, long service life.
Hard alloy coated sealing surface, its hardness is up to HRC60-62,
acid/alkali corrosion resistance, with high sealing reliability.
Suitable for sand content oil service and being flush erosion resistant
because of the hard alloy coatedsealing surface.
It can endure the high temperature
of 150 for light oil; 300 for
heavy oil.
It can endure the high temperature
of 150 for light oil; 300 for
heavy oil.
The internal leakage level is up to
GB/T4213-1992 / and
ANSI/FCI 70-2-1999/.
It will take very short time to select
the required position of valve and it
only takes less than 15 seconds to
7/29/2019 20111109181038317
3/14
Page 3 of 14
arrive at the next valve position.
It is with very a little abrasion loss of the hard alloy sealing surface, besides,
the clearance between the sealing surfaces can be self offset with its special
design structure.
The flow channel within the valve body is designed of all circular arc shape
transition so that the flow resistance factor is very small. The wall thickness
of the valve body is proper designed for a very long life span.
Adopt digital technique to inspect/test the valve position and the signal is
stable and accurate; the total position determination error is only0.5.
The wave spring for pre-pressure compensation is installed under thebottom of the motive seal within the valve, and an adjusting/checking hole is
specially designed on the valve bonnet, we can open it to adjust the
pre-pressure when necessary. It is convenient for check and maintenance of
the Multi-port Flow Selector Valve too.
The Remote Control Mode: Be able to realize computer control operation via
communication mode 485. The Stepping Mode: Turn the stepping switch
(on/off) by hand for stepping operation. Hand Wheel Operation Mode: Turn
the hand wheel by hand for operation on site.
Fire test in conformity with API spec 6FA.
7/29/2019 20111109181038317
4/14
Page 4 of 14
Description
The common pressure level for Multi-port Valve is to seePage 10.
The normal Diameter of Multi-port Valve is to seePage 10.
The common use material of Multi-port Valve is to seePage 10.The electrical powered driving unit of Multi-port Valve is explosion-proof
Exd BT4 and protection level IP 67 .
The international and national patents No.s 200420006528.1
200420073455.8 200620019902.0200620135470.X200620167076.4
PCT/CN2007/000888 PCT/CN2007/002012.
7/29/2019 20111109181038317
5/14
Page 5 of 14
Options
Pressure rating for multi-port valve and flange connection.
Connection pipe wall thickness (Schd).
Material of Multi-port Valve.The oil-inlet port size of Multi-port Valve
for a single well.
The group outlet port size of Multi-port
Valve.
Control system of Multi-port Valve:
control box, explosion-proof control box,
and integrated control system.
Motor Voltage: 380VAC220VAC110
VAC 24VDC1350 PRMYDF.
The output torque and rotation speed of explosion-proof electrical powered
driving unit of Multi-port Valve: 600N.m800 N.m1200N.m1500N.m
2500N.m0.5/0.2RPM.
Third part inspection & certification agency e.g. DNA, CCS etc. or any
specified on.
7/29/2019 20111109181038317
6/14
Page 6 of 14
Assembly of Multi-port Valve
12346 578910
11
12
13
14
15
19
20
21
22
23
24
29
30
31
32
25
26
27
28
33
36
38
39
40
41
42
43
44
45
37
46
16
17
18
34
35
Name
No.
1
Va
lveb
ody
2
"o"-sea
ling
ring
3
Tapere
dro
ller
bearing
4
5
Dra
inagescrewp
lug
6
Ro
tationplug
"o"-sea
ling
ring
7
Interna
l-hexadju
stingnu
t
8
9
Thrus
twas
her
10
Sea
lingring
Fan-s
hape
dva
lve
sea
tring
Me
talc
ladgas
ke
t
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
"o"-sea
ling
ring
"o"-sea
lingring
"o"-sea
ling
ring
Se
tscrew
Adjus
ting
nu
t
We
ldingfla
nge
Studbolt
Va
lve
bonne
t
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
Dishe
dspring
Tapere
dro
ller
bearing
Nu
t
Flatwash
er
Springwas
her
Re
tainerrin
g
Screwplug
Name
No.
Pac
king
filler
Pac
kingg
lan
d
Stud
Nu
t
Flatwas
her
Springwas
her
Bo
ltbo
lt
Spacer
Flatkey
Ac
tua
tor
brac
ke
t
A
ssemblyindica
tingarrow
Inner-
hex
tapere
dloc
kingscrew
Va
lvepos
ition
indica
ting
board
Flatwas
her
Springwas
her
Inner-
hex
tapere
dloc
kingscrew
Lifting
ba
il/Lug
Greasecup
Bo
lt
Nozz
lesea
linggas
ke
t
Additiona
l
Bo
lt
Flatwas
her
Springwas
her
7/29/2019 20111109181038317
7/14
Page 7 of 14
Fitting of Valve Seat Ring
Position Selection & Control
I ntegrated optical coupling circuit board and Photoelectric encoder devicecombined into a 4-way valve coded signal.
Four basic unit of optical encoder circuit is independent of each other,positive and negative can be wired, no damage to the circuit board.
Applying four miniature low-power relay output, with the outside worldcompletely isolated.Operating temperature -30 to 120.Applicable to both sink input and sourceinput connection wiring.
No mechanical wear.Positioning accuracy of 0.5 Working life to 106.
7/29/2019 20111109181038317
8/14
Page 8 of 14
Position Mode & Display
Switch ModeA But tonRedValve PositionB ButtonBlackStepping-OnStepping-Off.
Mode & DisplayValve Position ModeLLocalRRemoteRemote Control. SShut offStop.
Position Display011# Position022# Position033# Position044# Position,and so l ike.
Communication protocol & addressCommunication Mode: RS485
Communication protocol Modbus RTU protocolThe communication parameters default/acquiescence setting
Device Address 11-200
Baud rate 96001200,24004800,9600,19200,38400.
Parity: none (none, odd, even). Data Bits 8bits. Stop bits: 1.
Register address
There are 4 register addresses to be used by upper-computer (PC), using the standard
address format of Modbus Rtu protocol.
Valve position setting register address 40003
Valve position display register address 40004
Mode conversion register address 40005
Mode conversion register address 40006
Note:The register data format is of decimal system.
7/29/2019 20111109181038317
9/14
Page 9 of 14
Electrical princip le
Terminals Diagram for Wiring
D1 D2 D3 D4 ZH1 Z H2 ZH 3 GZ
6 7 8 9 11 12 13
S IEMENSS7-200
CP U 224XP CN
214-2BD23-OXB8
10 14
BJ
R S 4 8 5
Note:The communication wire for RS485 has been connected to theterminal inside the electrical driving head,while there is acorrespouding wire connection terminal outside forconveniently wiring out.
ELECTRONIC DIGITAL DISPLAY BOARD
F
U
S
E
1
BX
D1
D2
D3
D4
ZH1
ZH2
ZH3
BJ
0 V
1
2
4
3
2
3
4
5
6
7
10
11
12
13
14
0 V
24V
24V
8
9
0V 0.5A
0 Volt PUBLIC TERMINALS 0V
BX15
GZ
0 Volt ELECTRIACAL FUSE 0.5A
STEPPING SIGNAL
OVERLOAD SIGNAL
CUT SIGNAL
LOCAL SIGNAL
REMOTE SIGNAL
SIGNAL 1
SIGNAL 2
SIGNAL 3
SIGNAL 4
24V 0.5A24 Volt ELECTRIACAL FUSE 0.5A
0 Volt PUBLIC TERMINALS 0V
24 Volt PUBLIC TERMINALS 24V
24 Volt PUBLIC TERMINALS 24V
7/29/2019 20111109181038317
10/14
Page 10 of 14
Size & Specification of MSV
Service Heavy oil/light oil
Medieum Temp.() -29300
Operation Temp.() -3070
Nominal Pres.(lb) 150,300,400,600,900,1500,2500
oil-inlet ports 4681012141516,18
oil-inlet Port Nominal Dia.inch
1
2,3
4,1,
114
,2,1
22
,3,1
32
,4,6,8,10
Test out-let port Nominal
Dia.inch
1
2,3
4,1,
114
,2,1
22
,3,1
32
,4,6,8,10
Group-outlet Port Nominal
Dia.inch
3
4,1,
114
,2,1
22
,3,1
32
,4,6,8,10
Control System Common control box; Explosion-proof control
box; Integrated Mechano-eletronic Control box
Output TorqueNm 600,800,1000,1200,1500,2500,5000
Output Rotation speed
r/Min
0.2,0.3,0.5
Valve Body material A216M-WCB,A351M-CF8A351-CF3M,
A487M-1C,Duplex stainless steel,etc.
Bolts &Nuts Standard ASTM A193/193M ASTM A194/194M
valve Seat Leakage level
Power Driving Actuator Explosion-Proof ClassExdBT4
Note: The data within the table are common used data, but the nominal
Dia. & Pres. and material of MSV can be designed on the basis of the
users requirements.
7/29/2019 20111109181038317
11/14
Page 11 of 14
Kitsnet MSV Outline Figures
2150 lb MSV Outline Figures
Unit:mm.
7/29/2019 20111109181038317
12/14
Page 12 of 14
Kitsnet MSV utline Figures3300 lb MSV Outline Figures
Unit:mm.
7/29/2019 20111109181038317
13/14
Page 13 of 14
Kitsnet MSV Outline Figures4900lb MSV Outline Figures
Unit:mm.
7/29/2019 20111109181038317
14/14
Page 14 of 14
Contact us
Business Contact:
Telephone: 86 +0990-6223690/13999301712
Email: [email protected]
Technical Support:
Telephone:86+09906228306/13999501886
Email: [email protected]
After-sale Service:
Telephone:86+ 09906879900/13999515675/13565456395
Email: [email protected]/[email protected]
Fax:86+ 0990-6228306/6223690
Website: h ttp//www.ki tsnet.cnKelamayi King-Bull Infortec Petroleum Equipment Company, Ltd.
Address: No.30#,Ashan Road, Kelamayi City, Xinj iang, China.
Post code: 834000