Top Banner
©2009 | Friday 10 June 2022 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE
26

©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Dec 21, 2015

Download

Documents

Alicia Hicks
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 1

Cavotec Airport

Cavotec Ground Cooling Solutions – Pre-conditioned AirDubai Airport Show – May 2015Dubai, UAE

Page 2: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

This is Cavotec

• Since 1974, a global engineering group developing and manufacturing innovative power transmission , distribution and control technologies solutions that form the link between fixed and mobile equipment in the Ports & Maritime, Airports, Mining & Tunnelling and General Industry

• Listed in NASDAQ OMX

• Consolidated revenues of EUR 233 M

• More than 1000 employees of which 280 University graduates

• Present in all continents through its 35 subsidiaries

Uniquely positioned to provide a local customer oriented approach while being backed by the worldwide Group network

Cavotec operates in four diversified Market Units:

•Ports & Maritime

•Airports

•Mining & Tunnelling

•General Industry

Overview of Cavotec

©2009 | Wednesday 19 April 2023 | Slide 2

Page 3: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Cavotec Airport Market Unit

©2009 | Wednesday 19 April 2023 | Slide 3

AVIATION

• We are a specialist in our field of expertise, capable of consulting and engineering airport solutions for our clients. Our systems improve the operational efficiency, provide a quick R.O.I. based on the capital investment and ensure the airport becomes more environmentally friendly.

• We are an OEM, but also act as a system integrator in order to deliver a functional guarantee to our clients.

• Based on the situation of a project, we will engineer the best technical solution for our clients – our wide product portfolio and in-house engineers allow us to provide an engineering based approach on project criteria.

• Our competence has been demonstrated around the globe over the past 40 years as a system provider for commercial and military airports as well as MRO facilities.

• We are a specialist in our field of expertise, capable of consulting and engineering airport solutions for our clients. Our systems improve the operational efficiency, provide a quick R.O.I. based on the capital investment and ensure the airport becomes more environmentally friendly.

• We are an OEM, but also act as a system integrator in order to deliver a functional guarantee to our clients.

• Based on the situation of a project, we will engineer the best technical solution for our clients – our wide product portfolio and in-house engineers allow us to provide an engineering based approach on project criteria.

• Our competence has been demonstrated around the globe over the past 40 years as a system provider for commercial and military airports as well as MRO facilities.

Page 4: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air (PCA) - Key benefits

©2009 | Wednesday 19 April 2023 | Slide 4

PCA is an external ground service enabling aircrafts to be cooled on ground without the use of the Auxiliary Power Unit (APU)

Reduced air & noise

pollution

Improved cabin

thermal comfort

Shorter turnaround

time

Lower operational

costs for airlines

New revenue

stream for airlines

Page 5: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air (PCA) – New market players, new challenges

©2009 | Wednesday 19 April 2023 | Slide 5

Bigger aircrafts, more modern with multiple on-board equipments and operated in hot ambient conditions are challenging the industry in engineering higher PCA cooling performance systems

Traditional aviation markets

New mid-end markets (15 years)

New high-end markets (10 years)

Extreme temperature, humidity and VLA

High humidity

High humidity

Page 6: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air (PCA) – Industry standards

©2009 | Wednesday 19 April 2023 | Slide 6

As a result, airlines and aircraft manufacturers have been looking for higher PCA cooling performance and the industry had to create a new standard with the AHM997

Page 7: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2010 | Wednesday 19 April 2023 | Page 7

Development of Subfreezing Standard AHM-997

AHM 974Functional specification for aircraft air conditioning unitMin inlet temp +1°C

Airbus AMM +2°CBoeing MFEPD +2°C

Current standardIATA Aircraft Handling Manual

AHM 997Functional specification for Subfreezing aircraft air conditioning unit

Inlet temp below +2°C

Published in Jan 2012IATA Aircraft Handling Manual

AMM – Airbus*MFEPD - BoeingAircraft Maint. Man.

Specifies the operating procedures and limitations for Subfreezing PCAir

A319-A321A330, A340, A380A350 pending

Rel. by Aircraft manufacturer:

ACAircraft Characteristics

Specifies the required massflow and temp for ground cooling

Cooling performance curves for OAT46°C added in Airbus AC

Rel. by Aircraft manufacturers:

NEW STANDARD NEW REVISION

Released to Airliner/CustomerNDA is required for GSE supplier

Official documentsAvailable on Internet

Part of IATA AHM HandbookPart of IATA AHM Handbook

OLD STANDARDNEW

REVISION

Airbus Compliance doc

for Subfreezing cooling:

X21RP1146224_v6

NEW DOCUMENT

Page 8: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air (PCA) – Industry standards

©2009 | Wednesday 19 April 2023 | Slide 8

Main difference between the standards

Page 9: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air (PCA) – System cooling performance

©2009 | Wednesday 19 April 2023 | Slide 9

Su

bfr

eezi

ng

Su

bfr

eezi

ng

Page 10: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

•APU can be switched off while on stand/gate

•Full design and performance responsibility from the PCA up to the aircraft inlet

•PCA technology range suitable for all aircraft categories (up to Code F, down to -25°C discharge temperature) and suitable for all ground handling operations in all climates

•Faster pull down and cabin cooling time for a reduced aircraft Turn Around Time (TAT)

•Improved cabin comfort (with reduced humidity) for an enhanced passenger experience

•Best-in class Sub-freezing PCA with a tested and approved safety system (AHM997) interfacing with the Visual Docking Guiding System (VDGS) eliminating possible human error

•Cavotec Gate Operator Terminal pre-defined with individual settings and limitations for all aircraft types according to AHM997 and AHM974

•Reduced APU maintenance costs

•PCA system designed for collision avoidance with Cavotec pit systems

•PCA pits including hoses and connectors engineered for a minimum cooling loss

•Design versatility adaptable to any site location (contact gates, remote apron & MRO facility)

Pre-conditioned Air (PCA) – Benefits with Cavotec systems

Page 11: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air – Dubai Airport – AHM 974

First time in the world – Hi-performance DX-PCA Unit for A380 using the Super-cool Technology

Page 12: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Pre-conditioned Air – Dubai Airport – AHM 974

First time in the world – Hi-performance DX-PCA Unit for A380 using the Super-cool Technology

Page 13: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 13

Cavotec E³ SystemAn independant System Solution with it‘s own trade mark.

The E³ system is designed for the new international airport standard: “Multiple Aircraft Ramp System“ and it supports the integration of:- PC Air system- 400Hz system- Visual Guiding Docking Systemand other GSE system.

The E³ system conforms to AHM997Safety requirements for sub-freezing ground cooling according to IATA AHM997 standard.

Airport Network

CavotecE³ Network

Pre-conditioned Air (PCA) – Sub-Z Safety features

Page 14: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

• Functional PCA system: Central Sub-freezing DX Boost PCA system (AHM974 & AHM997)

PCA Pop-up pitDX Boost PCA

Underground piping

Central chilled water plant

• 3 to 4 cooling stages• CW + Vapor cycle Direct Expansion• Complies with AHM997 & AHM974

• Air flow variable 60-300kg/min• PCA outlet temperature range: -25°C for cooling, up to 55°C for heating.• Air pressure up to: 12500Pa• Noise level: <85dB at 4.6m distance in all directions.• Design condition up to dry-wet bulb 50°C/30°C ambient• Compressors: fully hermetic scroll• CW temperature: 7°C/14°C

Technical characteristics

Pre-conditioned Air (PCA) – Sub-Z Safety features

Page 15: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 15

• Cavotec Subfreezing PC Air Adapter (patent pending) with integrated sensors measuring inlet temp and static inlet pressure

• Gate PLC interface with Touch Screen Operator Panel and implemented safety logic for MARS Gate configuration eliminating human error and incorrect settings of mass flow and inlet temp.

Pick up points for

static pressure

Sensor #1

Sensor #2

Pre-conditioned Air (PCA) – Sub-Z Safety features

Page 16: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Gate Operator Terminal Operator Menus

Start screen

View settings Process values

Alarm main menu

Alarm PCA LeftAlarm PCA Right

Alarm pages can be reached from all screens

D/E/F center

Aircraftnot OK

Aircraft not OK, newselection from Supervisor

Alarm log PCA LeftAlarm log PCA Right Alarm log PCA Center

Alarm PCA Center

C - LeftC - Right

Operator main sequence

Page 17: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Cavotec’s AHM997 PCA Timeline – In operation

Starting in 2005, Cavotec had launched a Subfreezing PCA R&D program.

Emirates Airline asked Cavotec to help them.

The project was initiated and a cooperation with Airbus started.

Cavotec makes successful test lab demonstration of Subfreezing PCA for Airbus

Cavotec makes Subfreezing aircraft ground cooling tests at Airbus in Toulouse.Aircraft tested: A320, A340-600 and A380-800

Cavotec makes Subfreezing aircraft ground cooling tests in Dubai. The test is attended and supported by Airbus. Aircraft tested: A330-200, A340-500, B777-300

Bahrain International Airport awards Cavotec for the first world subfreezing PCA system (-25°C) Cavotec makes Subfreezing aircraft ground cooling tests in Singapore, Dubai and Bahrain. The test is attended and supported by Airbus. Aircraft tested:A330-200, A340-500, A380-800, B777-200, A340-300

Subfreezing tests in Abu Dhabi and Bahrain

Abu Dhabi DMW awards Cavotec for 2 new DX-Boost PCA capable of delivering subfreezing air (-10°C)

First release of the AHM997

Airbus release the Subfreezing Compliance Document for Suppliers:X21RP1146224 Rel 1.0

©2009 | Wednesday 19 April 2023 | Slide 17

2008 2009 2010 2011 2012 2013

Cavotec is awarded 8 DXBoost PCA for Boeing Bagpur hangars. -15°C can be produced by the machines

Cavotec pioneered the Subfreezing PCA and has now 3 systems in operation capable of discharging at least -10°C at the PCA outlet

Page 18: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Cavotec’s PCA systems – PCAIR In operation Airport

©2009 | Wednesday 19 April 2023 | Slide 18

Bahrain International Airport – BahrainDischarge temperature: -25°C

Page 19: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Cavotec’s PCA systems – DXBoost in operation

©2009 | Wednesday 19 April 2023 | Slide 19

Boeing Nagpur hangars – IndiaDischarge temperature: -15°C

Page 20: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 20

Boeing Nagpur hangars – IndiaDischarge temperature: -15°C

Cavotec’s PCA systems – DXBoost in operation

Page 21: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 21

DMW hangars – UAEDischarge temperature: -10°C

Cavotec’s PCA systems – DXBoost In operation

Page 22: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 22

DMW hangars – UAEDischarge temperature: -10°C

Cavotec’s PCA systems – DXBoost In operation

Page 23: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 23

Cavotec’s PCA systems– PCA Pop-up

Page 24: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

©2009 | Wednesday 19 April 2023 | Slide 24

Cavotec’s PCA systems– Airbus Fast Magazine

Page 25: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

• Cavotec has been able to initiate the definition and adoption of a new cooling method and standard

• Aircrafts being bigger and more equipped and operated in severe ambient conditions require the AHM997 as a standard method for an efficient aircraft cooling and under all conditions

• Safety features are critical - a permanent control of the PCA flow and pressure is a must and shall not be neglected

• The subfreezing has to be engineered as a complete system for maximizing its performance and reducing the potential design liability risks

SUBFREEZING, GOING BEYOND THE HORIZONS

Cavotec’s PCA systems – Conclusion

Page 26: ©2009 | Friday, 03 July 2015 | Slide 1 Cavotec Airport Cavotec Ground Cooling Solutions – Pre-conditioned Air Dubai Airport Show – May 2015 Dubai, UAE.

Thank you for your attention