Top Banner
1 We offer to you high grade > Quality of products and services > Logistics value added services > Commercial support > Staff knowing that our success depends on yours Features > Extremely compact design with convenient mounting styles > Equipped with touch safeterminal blocks > High attenuation characteristics over a broad frequency spectrum > Available in very low leakage current > Current rating coverage up to 180A / 680VAC & UL-approved > Filters do provide drop-in replace ability against industry standard EMI filters Applications > Industrial 3 phase systems > Conventional and regenerative motor drives, elevators, Cranes, UPS systems, machine tools, robotics, automation machinery, and many more Why to choose Delta? > World class leading manufacturer of EMI filter products – 27 years experience > Listed on Forbes Asian Fab 50 of most successful companies in Asia > Owner of countless Vendor-of-the year awards of leading multinationals > Environmental consciousness in our culture and corporate disciplines Powerful in > Production capacity > Design support and flexibility > Offering market compliant products against beneficial conditions > Rapid turn around time for approval samples We facilitate your EMI testing & engineering Quality • Reliability • Excellence
8
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 2009 EMI Filter News for Industrial 3 Phase systems

1

We offer to you high grade > Quality of products and services > Logistics value added services > Commercial support > Staff knowing that our success depends on yours

Features > Extremely compact design with convenient mounting styles > Equipped with “touch safe” terminal blocks > High attenuation characteristics over a broad frequency spectrum > Available in very low leakage current > Current rating coverage up to 180A / 680VAC & UL-approved > Filters do provide drop-in replace ability against industry standard EMI filters

Applications > Industrial 3 phase systems > Conventional and regenerative motor drives, elevators, Cranes, UPS systems, machine tools, robotics, automation machinery, and many more

Why to choose Delta? > World class leading manufacturer of EMI filter products – 27 years experience > Listed on Forbes Asian Fab 50 of most successful companies in Asia > Owner of countless Vendor-of-the year awards of leading multinationals > Environmental consciousness in our culture and corporate disciplines

Powerful in > Production capacity > Design support and flexibility > Offering market compliant products against beneficial conditions > Rapid turn around time for approval samples

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 2: 2009 EMI Filter News for Industrial 3 Phase systems

2

EMI FILTER TDV-1 series

* Option for high voltage 520VAC is available with “HV” suffix

Specification is subject to change without notice

Figure

Dimension

Schematics

INTRODUCTION

> For three phase systems (Power supplies, UPS, elevators, robots etc.) and motor drives up to 50m cable length > Broadband attenuation from 150kHz to 30MHz

> Very Compact and slim design

> Touch safe terminal blocks

> Compliance with class A limits

SPECIFICATION

> 3 phase 3 wire system > Filter stage 1 stage

> Voltage rating 480VAC/520VAC* > Terminal block

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH [mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

07TDVST2-1 7 162x42x72 Terminal block <30

16TDVST2-1 16 222x47x72 Terminal block <30

30TDVST2-1 30 242x52x87 Terminal block <30

42TDVST2-1 42 282x52x87 Terminal block <30

55TDVST2-1 55 222x87x92 Terminal block <30

75TDVST2-1 75 202x122x66 Terminal block <30

100TDVST2-1 100 240x90x150 Terminal block <30

130TDVST2-1 130 240x90x150 Terminal block <30

180TDVST2-1 180 350x120x170 Terminal block <30

07TDVST2-1

Insertion loss (common mode)

07TDVST2-1

42TDVST2-1

55TDVST2-1

30TDVST2-1

75TDVST2-1

100TDVST2-1

130TDVST2-1

0 10 20 30 40 50 60 70 80

0.01 0.1 1 10 100frequency (MHz)

dB

180TDVST2-1

16TDVST2-1

Insertion loss (differential mode)

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100

frequency (MHz)

dB

42TDVST2-1

55TDVST2-1

30TDVST2-1

75TDVST2-1

100TDVST2-1

130TDVST2-1

180TDVST2-1

16TDVST2-1

07TDVST2-1

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 3: 2009 EMI Filter News for Industrial 3 Phase systems

3

EMI FILTER TDRT2-1 series

* Option for voltage 480VAC is available for 50A and 80A with “A” suffix

Specification is subject to change without notice

INTRODUCTION

> For conventional and regenerative motor drives, elevators, cranes, UPS

> High broadband attenuation from 9kHz to 30MHz

> Slim book style

> Touch safe terminal blocks

> Enables compliance with class B limits

Figure

Dimension

Schematics

SPECIFICATION

> 3 phase 3 wire system > Filter stage 1 stage

> Voltage rating 520VAC/480VAC* > Screw type, terminal block

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH [mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

35TDRT2-1 35 305x60x150 Terminal block <48.9

50TDRT2-1 50 300x80x185 Terminal block <66.1

80TDRT2-1 80 350x90x220 Terminal block <71.5

110TDRT2-1 110 350x90x220 Terminal block <71.5

150TDRT2-1 150 400x110x240 Terminal block <71.5

50TDRT2-1-A 50 300x80x185 Terminal block <66.1

80TDRT2-1-A 80 350x90x220 Terminal block <71.4

Insertion loss (differential mode)

36TDRT2-1

50TDRT2-1

80TDRT2-1

150TDRT2-1

110TDRT2-1

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100

frequency (MHz)

dB

Insertion loss (common mode)

35TDRT2-1

50TDRT2-1

80TDRT2-1

110TDRT2-1

150TDRT2-1

0 10 20 30 40 50 60 70 80

0.01 0.1 1 10 100frequency (MHz)

dB

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 4: 2009 EMI Filter News for Industrial 3 Phase systems

4

EMI FILTER TDSS series

* Option for high voltage 690VAC is available with “HV” suffix

Specification is subject to change without notice

Figure

Dimension

Schematics

INTRODUCTION

> High-power filter up to 180A for High-power motor drives, inverters and converters (>180A on request) > For High-power motor drives, inverters and converters, industrial 3-phase- systems, installations, large UPS etc. > Model for 690VAC IT power networks available

> Extremely compact with minimum space requirement

> Compliance with class A limits

SPECIFICATION

> 3 phase 3 wire system > Filter stage 3 stage

> Voltage rating 520VAC/690VAC* > Output connection: Screw type

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH [mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

150TDSS64 150 300x160x120 Screw on <6

180TDSS64 180 300x160x120 Screw on <6

Insertion loss (common mode)

180TDRST2

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100

frequency (MHz)

dB

Insertion loss (differential mode)

01020304050607080

0.01 0.1 1 10 100frequency (MHz)

dB

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 5: 2009 EMI Filter News for Industrial 3 Phase systems

5

EMI FILTER TYT8, TYS10 series

Max. leakage under normal circumstances. Note: if two phases are interrupted, worst-case leakage current could reach 6.0 times higher level.

Specification is subject to change without notice

Figure

Dimension

Schematics

INTRODUCTION

> For general purpose: AC motor drive, machine tools, robot, UPS etc.

> Low leakage current

> Compliant with IEC 60950

> High attenuation of common mode and differential mode

SPECIFICATION

> 3 phase 4 wire system > Filter stage 1 stage

> Voltage rating 440/250VAC > Terminal block, screw type

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH max.

[mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

16TYT8 16 142x107x82 Terminal block <0.43

25TYT8 25 142x107x82 Terminal block <0.43

36TYT8 36 142x107x82 Terminal block <0.43

50TYT8 50 144x124x104 Terminal block <0.43

100TYT8 100 212x162x132 Terminal block <1.33

150TYS10 150 302x162x132 Screw on <8.0

Insertion loss (common mode)

16TYT8

25TYT8

36TYT8

50TYT8

100TYT8

150TYS10

0

10

20

30

40

50

60

70

0.01 0.1 1 10 100

frequency (MHz)

dB

Insertion loss (differential mode)

16TYT8 25TYT8

36TYT8

50TYT8

100TYT8150TYS10

0

10

20

30

40

50

60

70

0.01 0.1 1 10 100

frequency (MHz)

dB

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 6: 2009 EMI Filter News for Industrial 3 Phase systems

6

EMI FILTER TYT8-1 series

Specification is subject to change without notice

Figure

Dimension

Schematics

INTRODUCTION

> For three phase systems (industrial machinery)

> Compact design

> High attenuation

> Very low leakage current

> According to machinery tool standard EN 50370-1

SPECIFICATION

> 3 phase 4 wire system > Filter stage 1 stage

> Voltage rating 520/300VAC > Touch safe terminal blocks

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH [mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

08TYT8-1 8 110x82x70 Terminal block <1

16TYT8-1 16 110x82x70 Terminal block <1

25TYT8-1 25 130x90x85 Terminal block <1

36TYT8-1 36 130x90x85 Terminal block <1

64TYT8-1 64 140x115x115 Terminal block <1

80TYT8-1 80 170x135x125 Terminal block <1

120TYT8-1 120 210x140x125 Terminal block <1

160TYT8-1 160 200x160x130 Terminal block <1

Insertion loss (common mode)

25TYT8-1

16TYT8-1

08TYT8-1

36TYT8-1

64TYT8-1 80TYT8-1

120TYT8-1

160TYT8-1

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100frequency (MHz)

dB

Insertion loss (differential mode)

16TYT8-1

08TYT8-1

36TYT8-1

25TYT8-1

64TYT8-1

80TYT8-1

120TYT8-1

160TYT8-1

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100frequency (MHz)

dB

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Page 7: 2009 EMI Filter News for Industrial 3 Phase systems

7

EMI FILTER TYT8-2 series

Specification is subject to change without notice

Figure

Dimension

Schematics

INTRODUCTION

> For industrial machinery

> Compact design

> Very high attenuation

> Low leakage current

> For machines in mixed/domestic environments (class A/B)

SPECIFICATION

> 3 phase 4 wire system > Filter stage 2 stage

> Voltage rating 520/300VAC > Terminal block

> Operating frequency 50/60 Hz > Approvals

> Climatic category 25/100/21 > According EN 60939-2

MODEL CURRENT RATING

[A]

DIMENSION LxWxH [mm]

MOUNTING STYLE

LEAKAGE CURRENT

[mA]

8TYT8-2 8 120x115x80 Terminal block <1

16TYT8-2 16 120x115x80 Terminal block <1

25TYT8-2 25 130x125x115 Terminal block <1

36TYT8-2 36 130x125x115 Terminal block <1

64TYT8-2 64 160x125x125 Terminal block <1

80TYT8-2 80 230x135x125 Terminal block <1

120TYT8-2 120 250x140x140 Terminal block <1

160TYT8-2 160 280x140x170 Terminal block <1

We facilitate your EMI testing & engineering

Quality • Reliability • Excellence

Insertion loss (common mode)

08TYT8-1

16TYT8-2

36TYT8-225TYT8-2

64TYT8-2 80TYT8-2

120TYT8-2

160TYT8-2

200TYT8-2

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100frequency (MHz)

dB

Insertion loss (differential mode)

08TYT8-2

08TYT8-2

36TYT8-225TYT8-2

64TYT8-280TYT8-2

120TYT8-2

200TYT8-2

160TYT8-2

0

10

20

30

40

50

60

70

80

0.01 0.1 1 10 100frequency (MHz)

dB

Page 8: 2009 EMI Filter News for Industrial 3 Phase systems

8

Our MissionTo provide innovative, clean and efficient Energy solutions for a better tomorrow

Contact: Christian Schweder R & D Manager, EMC Solutions Delta Electronics German office: Coesterweg 45, D-59494 Soest Phone: +49 (0) 2921-987 626 Fax: +49 (0) 2921-987 620 Mobile: +49 (0) 170-7683 096 Email: [email protected]

> ISO 9001 certified> IS0 14001 certified > Green partner > TS 16949 certified > OHSAS 18001 certified > CSA22.2 No.8 self-testing accredited

Manufacturing plant in Thailand

Quality • Reliability • Excellence

Rene Winkelman Business Development & Sales Manager Delta Electronics European Headquarters: Zandsteen 15, NL- 2132 MZ Hoofddorp The Netherlands Phone: +31(0) 20 655 0921 Fax: +31(0) 20 655 0999 Mobile: +31(0) 65085 9644 Email: [email protected]

European Headoffice Amsterdam

EMI Competence Center Soest, Germany

We support you with: EMI-Consulting EMI-measurements according

to EN-standards (EN55011, EN55022, EN 61800-3 etc.)

Delta Lab Facility Onsite (200Amp max.)