Whats NewCONNECTORS Break-Away Lugs . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . C-11 CONNECTORS Blank
Tongue Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C-12, C-13
CONNECTORS YGHC Updated Connectors . . . . . . . . . . . . . . .
. . . . . . . . . . . E-11
BHSG1100 New Heat Shrink Gun . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . F-14
GCRT1/0 Range Taking Ground Rod Clamp . . . . . . . . . . . . .
. . . . . . . . E-44
WHSSAPD WEJTAP Hotstick Adapter. . . . . . . . . . . . . . . . .
. . . . . . . . . J-31
WEJTAP In-Line Disconnect. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . J-27
GTC Protective Grounding Clamp . . . . . . . . . . . . . . . . .
. . . . . . . . E-50 (Continued on next page)Throughout the catalog
you will notice blue highlighted items. These are the most
frequently ordered BURNDY Products. US: 1-800-346-4175
www.burndy.com Canada: 1-800-387-6487
BURNDY Products
Mechanical
A-1
TABLE OF CONTENTSTypes KS, KS-3 & SC. . . A-4 Type KSU . . .
. . . . . . . . . A-5 Type KSA . . . . . . . . . . . . A-6 Types
KVS, KVSU. . . . . . A-7 Types KVSW, KVS-A . . . A-8 Type QPX . . .
. . . . . . . . . A-9 Type QPX-Y . . . . . . . . . A-10 Type KPA .
. . . . . . . . . . A-11 Type KPA-UP . . . . . . . . A-12 Type KLU
. . . . . . . . . . . A-13 Types KA, EA . . . . . . . . A-14 Types
BGBL, CL50-1 . . A-15 Types QA, QQA . . . . . . A-16 Types Q2A, Q3A
. . . . . . A-17 Types QB, Q2B . . . . . . . A-18 Types QDA &
QR . . . . . A-19 Types VT, E-C-G . . . . . . A-20 Types K4A-U,
KK4A, K11A-U, K21A, K22A. A-28 Type KAU-KIT. . . . . . . . A-29
Type AMS . . . . . . . . . . . A-30 Type AGSKIT . . . . . . . .
A-31 Type UGSKIT . . . . . . . . A-31 Type UGSKIT8 . . . . . . .
A-32 Type UGS350ULDB . . . A-32 Type QGFL . . . . . . . . . . A-33
Type FCB . . . . . . . . . . . A-34 Types KPU-AC, UCU-AC . . . . .
. . . . . . A-35Complies with NFPA 78-86 Ordinary Structures.
Complies with NFPA 78-86 Heavy Duty Stacks (order: LD for Lead
Plating for Heavy Duty Stacks applications.)
Types VA, VVA . . . . . . . A-21 Type HFB-P1 . . . . . . . .
A-22 Type HFB-N . . . . . . . . . A-23 Types KA-U, KKA-U. . . A-24
Type K2A-U . . . . . . . . . A-25 Types K3A-U, KK3A-U . . . . . . .
. . . . . . . A-26, A-27
Type BIPC . . . . . . . . . . . A-36 SPEC-BLOK . . . . A-37,
A-38 SPEC-BLOK PLATFORMS . . . . . . . A-39 Types BDA, BDB, BDC . .
. . . . . . . A-41, A-42, A-43, A-44, A-45 Types BIT, BISR . . . .
. . A-46 Type BIBS . . . . . . . . . . . A-47 Type BIBD. . . . . .
. . . . . A-48 Types BIBS-MT, BIBD-MT. . . . . . . . . . . A-49
Type BISR-DB . . . . . . . A-50 Type 1PL . . . . . . . . . . . .
A-51
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-2
Mechanical
BURNDY Products
LIGHTNING PROTECTION INFO.Basic rules for selection are: 1 Must
be like material to the conductor (Flexitap out due to steel
bolts!). 2. Two bolts to ground rod minimum. 3 Cable to cable
connections can be anything one bolt, two bolt, compression, etc. 4
Cable to steel structure must have 8 square inch contact with
steel. 5. Heavy duty stacks mechanical only. 6. On all connectors
with heavy duty stack rating, we must offer 1/16 thick lead plating
as an option. Reason is closest 25 ft. to stack opening must use
lead coated product. Complies with NFPA 78-86 Ordinary Structures.
Complies with NFPA 78-86 Heavy Duty Stacks (order: LD for Lead
Plating for Heavy Duty Stack applications)
SPECIAL FEATURESOther features are also available for products
listed in price book such as undrilled or special drilling, 45 or
90 pad angles, belling for extra flexible cable, smooth or special
threaded studs, special labeling or packaging, extra long braid,
and nuclear certification. REFER TO FACTORY.
ALL OTHERS REFER TO FACTORY 1-800-346-4175
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-3
REVOLUTIONARY BURNDY DESIGN MEETS STRICT UL 486B STANDARDS. . .
and puts the bite on aluminum connections forever!For use on all
combinations Aluminum to aluminum Aluminum to copper Copper to
copper PatentedAvailable in sizes from #10 through 500 kcmil.
Unique bite and grip TRITAP SERVIT contact delivers safe,
long-term reliabilityeven without scratch brushing . . . without
oxide inhibiting compounds.
Spacer provides built-in separation to retard galvanic
corrosion.
Triangular edges bite into cable to break through surface oxides
...provide low contact resistance. ...produces gas tight seal.
Tin-plated contact surface inhibits oxide formation.
Special heat-treated hard, aluminum alloy.
Anti-galling, high efficiency threaded components result in high
contact force. Easily installed using standard, everyday
wrenches.
When used in NEC applications of insulated cables only.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-4
Mechanical
BURNDY Products
TYPES KS & KS-3SERVIT For Copper, CopperweldCompact, high
strength, high copper alloy SERVIT split-bolt has free-running
threads and easy to grip wrench flats. Highly resistant to season
cracking and corrosion, the SERVIT provides maximum pressure and
assures a secure connection on all combinations of run and tap
conductors. Type KS-3 accommodates 3 maximum size conductors.
CONDUCTOR COPPER CATALOG NUMBER KS90 KS15 KS17 * KS17-3 KS20 *
KS20-3 KS22 * KS22-3 KS23 KS25 KS26 KS27 KS29 KS31 KS34 * KS39 *
KS44
COPPERWELD MIN. TAP WITH MAX. RUN16 Str. 14 Str. 14 Str. 16 Str.
14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 14 Str. 8 Sol. 8
Str. 1/0 Str. 2/0 Str. 4/0 Str. 4/0 Str.
RECOMMENDED TIGHTENING TORQUE in-lb80
CROSS FLATS.50 .50 .63 .69 .75 .82 .94 1.05 1.36 1.36 1.70 1.82
2.31 2.56
L.85 .85 1.14 1.20 1.50 1.54 1.77 1.94 1.86 2.07 2.51 2.79 3.29
3.73
W.38 .38 .45 .51 .60 .62 .73 .82 1.17 1.17 1.41 1.48 1.94
2.19
RANGE FOR EQUAL RUN AND TAP12 Str. - 10 Str. 10 Str. - 8 Str. 8
Str. - 6 Sol. 8 Str. - 6 Sol. 8 Str. - 4 Sol. 8 Str. - 4 Sol. 6
Str. - 2 Sol. 6 Str. - 2 Sol. 6 Str. - 2 Str. 4 Str. - 1/0 Str. 2
Str. - 2/0 Str. 1 Str. - 3/0 Str. 1 Str. - 250 1/0 Str. - 350 2/0
Str. - 500 4/0 Str. - 750 300 - 1000
SOL.#10 #8 #6 #6 #4 #4 #2 #2 #1 2/0 3/0 4/0
MAXIMUM RUN AND TAP STR. TYPE A TYPE D 3 #12 3 #12 3 #10 3 #10 3
#8 3 #8 3 #7 3 #5 7 #7 7 #5 19 #8 19 #6 19 #5 8A 8A 6A 6A 4A 4A 3A
2A 9-1/2D 9-1/2D 8D 8D 6D 6D 5D 4D
165
275 385 500 650 825 1000 1100
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations.
See note page A-2 * Not UL Listed or CSA Certified. In addition
to UL Listed for wire connectors and CSA Certified, these items are
also UL rated for direct burial.
TYPE SCSERVIT COVER HUG-A-BUGUsed indoors or outdoors, this
compact, one-piece plastic SERVIT cover saves time and material,
eliminates costly taping of split-bolts. Positive latch snaps
easily and quickly over connector, ideal for tight quarters.
Self-positioning plastic fingers wrap around wires fully insulating
joint. UL Listed for 600 volt indoor application with type KS.
Three Covers accommodate a range of 6 SERVIT sizes through 2/0
Str.
CATALOG NUMBERSC4 SC2 SERVIT and cover combination can be
ordered as follows: CKS4 KS20 with cover For other combinations,
please contact factory. SC2/0
FOR USE WITHKS17, KS17-3, KS20 KSU17, KSU20 KS22, KS20-3, KS23,
KS22-3, KSA6, KSA4, KSU22, KSU23 KS25, KS26, KSA2, KSA 1/0 KSU25,
KSU26
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-5
TYPE KSUUNIVERSAL SERVIT For All Combinations of Copper,
Aluminum, ACSR, AAAC, 5005, and SteelTin-plated, high strength
copper alloy SERVIT with spacer. Spacer separates dissimilar
conductors and provides long contact length that prevents high
pressure point contacts between run and tap conductors. Use of
PENETROX joint compound recommended with Aluminum and ACSR.Aluminum
& Copper Only 486A Copper Only
CONDUCTOR MAXIMUM CONDUCTOR STEEL SOL. 3 STR. NOM BWG BWG DIA.8
6 4 8 6 4 5/32 7/32 1/4 5/16 3/8 7/16 1/2 1/2 5/8
RUN CATALOG CROSS NUMBER FIG. FLATKSU17 KSU20 KSU22 KSU23 KSU25
KSU26 KSU27 KSU29 KSU31 KSU34 2 2 2 2 2 2 1 1 1 1 .62 .69 .74 .81
.93 1.04 1.38 1.38 1.69 2.00
TAP ACSR AAAC 5005 COPPER & ALUMINUM ACSR AAAC 5005
L.92 1.05 1.25 1.48 1.77 1.93 2.34 2.50 2.88
W
COPPER & ALUMINUM
RECOMMENDED TIGHTENING TORQUE in-lb.165 275 275 385 385 500 650
650 825
.42 12 SOL. - 6 SOL. .48 10 SOL. - 4 SOL. .57 10 SOL. - 2 SOL.
.59 8 STR. - 2 STR. .70 2 STR. - 1/0 STR. .79 1/0 STR. - 2/0 STR.
1.12 1 STR. - 3/0 STR. 1.14 1 STR. - 250 1.36 4/0 STR. - 350 400 -
500
3.12 1.47
8 (6-1) 12 SOL. - 6 SOL. 8 (6-1) 6 (6-1) 10 SOL. - 4 SOL. 6
(6-1) 6 (6-1) - 4 (7-1) 10 SOL. - 2 SOL. 6 (6-1) - 4 (7-1) 3 (6-1)
- 2 (6-1) 8 SOL. - 2 STR. 6 (6-1) - 2 (6-1) 3 (6-1) - 1 (6-1) 10
STR. - 1/0 STR. 6 (6-1) - 1 (6-1) 1 (6-1) - 1/0 (6-1) 8 STR. - 2/0
STR. 6 (6-1) - 1/0 (6-1) 1 (6-1) - 2/0 (6-1) 8 SOL. - 3/0 STR. 8
(6-1) - 2/0 (6-1) 2/0 (6-1) - 4/0 (6-1) 8 STR. - 250 6 (6-1) - 4/0
(6-1) 3/0 (6-1) - 4/0 (6-1) 4 STR. - 350 4 (6-1) - 4/0 (6-1) 336
(30-7) - 477 2 STR. - 500 2 (6-1) - 477 (18-1) (18-1)
Accommodates compressed conductors within conductor ranges. See
note page A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-6
Mechanical
BURNDY Products
TYPE KSATRITAP SERVIT For All Combinations of Aluminum to
Aluminum, Aluminum to Copper and Copper to Copper, Aluminum Alloy
Tin Plated PATENTED TRIANGULAR PENETRATION TECHNOLOGY CONTACT
Features and Benefits No scratch brushing required. No oxide
inhibitor required. Orients the conductor. Provides maximum
pressure and assures a secure connection of run and tap conductors.
Facilitates piercing the aluminum conductor surface oxides. UL 486B
listed, 90C rated. Provides a low contact resistance. Provides
equal coefficient of expansion Inhibits the reformation of oxides
by producing a gas-tight seal. Provides improved retention of
minimum to maximum conductor combinations.
CATALOG CROSS NUMBER FLATSKSA6 KSA4 KSA2 KSA 1/0 KSA 2/0 KSA 4/0
*KSA 350 *KSA 500 .75 .81 .94 1.00 1.12 1.49 1.69 2.00
L
W
ALUM. TO ALUM., ALUM. TO COPPER, COPPER TO COPPER CONDUCTORS
MAX. RUN TO MAX. TAP MIN. RUN TO MIN. TAP MAX. RUN TO MIN. TAP#6
Str. (.184) #4 Str. (.232) #2 Str. (.292) #6 Str. (.184) #4 Str.
(.232) #2 Str. (.292) #10 Sol. (.102) #10 Sol. (.102) #8 Str.
(.146) #8 Sol. (.129) #8 Str. (.146) #6 Str. (.184) #4 Str. (.232)
#6 Str. (.184) #4 Str. (.232) #2 Str. (.292) #1/0 Str. (.373) #2/0
Str. (.418) #4/0 Str. (.528) #350 KCMIL (.681) #10 Sol. (.102) #10
Sol. (.102) #8 Sol. (.146) #8 Sol. (.129) #8 Str. (.146) #6 Str.
(.184) #4 Str. (.232)
RECOMMENDED TIGHTENING TORQUE in-lb165 165 275 385 385 500 650
825
#10 Sol. (.102) #8 Sol. (.129) #6 Sol. (.169) #2 Str. COMPACT
1.92 .75 #1/0 Str. (.373) #1/0 Str. (.373) (.268) #2 Str. COMPACT
1.92 .88 #2/0 Str. (.418) #2/0 Str. (.418) (.268) #2 Str. COMPACT
2.54 1.13 #4/0 Str. (.528) #4/0 Str. (.528) (.268) #1/0 Str.
COMPACT 3.24 1.50 350 kcmil (.681) 350 KCMIL (.681) (.336) 400
kcmil 3.62 1.73 500 kcmil (.813) 500 KCMIL (.813) COMPACT
(.659)
1.28 .56 1.38 .62 1.58 .69
#2 Str. COMPACT #2 Str. COMPACT #500 KCMIL (.813) (.268)
(.268)
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations. * Not CSA Certified. ** No scratch brushing
or oxide inhibiting compounds required for insulated 90 C max.
rated conductor for N.E.C. applications.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-7
TYPE KVSOKLIP Mechanical Connector For Copper &
CopperweldCompact, two-piece, high strength, high copper alloy
BURNDY OKLIP recommended for heavy duty connections. Neoprene rings
hold DURIUM bolts in place during installation. Installed with
ordinary wrench.
CONDUCTOR COPPER CATALOG NUMBERKVS26 KVS28 KVS31 KVS34 KVS40
KVS44
RUN2 Str. - 2/0 Str. 1/0 Str. - 4/0 Str. 250 - 350 kcmil 400 -
500 kcmil 400 - 800 kcmil 500 - 1000 kcmil
TAP6 Sol. - 2/0 Str. 10 Str. - 4/0 Str. 10 Str. - 350 kcmil 10
Str. - 500 kcmil 3/0 Str. - 800 kcmil 3/0 Str. - 1000 kcmilSee note
page A-2
SOL.3/0 4/0
COPPERWELD MAX. RUN AND TAP STR.7 #8 7 #6 19 #8 19 #6 19 #5
TYPE V V3/0 V250 V350
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations.
TYPE KVSUUNIVERSAL OKLIP Mechanical Connector For All
Combinations of Copper, Aluminum, ACSR, AAAC & 5005Compact,
high strength, tin plated copper alloy two-piece connector with
spacer and tin-plated silicon bronze DURIUM hardware. Recommended
for heavy duty connections. Spacer separates dissimilar conductors
and provides long contact length. Neoprene ring prevents loss of
shorter bolt during installation. Longer peened bolt permits swivel
action for easier installation. Use of PENETROX joint compound
recommended with aluminum and ACSR.
CONDUCTOR RUN ACSR, AAAC, & 5005 RUN TAP COPPER COPPER ACSR,
SOL., SOL., AAAC, COPPERWELD STEEL COPPERWELD STEEL COPPER &
ALUM. & 5005 SOL., NOM. DIA. SOL., NOM. DIA. H1 - 3/0 2/0 - 4/0
5/16 - 7/16 3/8 - 1/2 9/16 - 5/8 3/4 - 3/4 3/4 - 1 7/8 - 1-1/8 #6 -
3/0 #6 - 4/0 #6 - 4/0 #4 - 4/0
TAP
CATALOG NUMBER COPPER & ALUM.KVSU26 KVSU28 KVSU31 KVSU34
KVSU40 KVSU44
J
L
W
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500
2 Str. - 2/0 Str. 3 - 2/0 6 Str. - 2/0 Str. 6 - 2/0 1/0 Str. -
4/0 Str. 1/0 - 4/0 6 Str. - 4/0 Str. 6 - 4/0 250 - 350 kcmil 4/0 -
300 AWG 6 - 350 kcmil 6 - 300 400 - 500 kcmil 336.4 - 397.5 AWG 4 -
500 kcmil 5 - 397.5 400 - 800 kcmil 4/0 - 800 AWG 4/0 - 800 kcmil
3/0 - 715.5 500 - 1000 kcmil 4/0 - 1000 AWG 4/0 - 1000 kcmil 4/0 -
900
3/16 - 7/16 2 5/16 1 1-1/2 5/32 - 1/2 2-3/8 3/8 1-1/8 1-3/4 3/16
- 5/8 2-5/8 1/2 1-3/8 2-1/8 7/32 - 3/4 3 1/2 1-1/2 2-1/4 1/2 - 1
3-1/2 1/2 1-5/8 2-1/2 1/2 - 1-1/8 4 3/8 2 3
Accomodations compressed conductors within diameter range. See
note page A-2
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
A-8
Mechanical
BURNDY Products
TYPE KVSWOKLIP Mechanical Connector For Copper and
Copperweld.Similiar to OKLIP Type KVS except for a high copper
alloy spacer that separates run and tap conductors. Provides high
contact pressure, confines conductor strands, and assures
vibration-proof connection. Longer peened bolt, permits swivel
action for easier installation. Silicon bronze DURIUM hardware.
CATALOG NUMBERKVSW26 KVSW28 KVSW31 KVSW34 KVSW40 KVSW44See note
page A-2
CONDUCTOR RUN2 Str. - 2/0 Str. 1/0 Str. - 4/0 Str. 250 - 350
kcmil 400 - 500 kcmil 400 - 800 kcmil 500 - 1000 kcmil
TAP6 Sol. - 2/0 Str. 6 Sol. - 4/0 Str. 4 Sol. - 350 kcmil 4 Str.
- 500 kcmil AWG 4/0 - 800 kcmil 250 - 1000 kcmil
RECOMMENDED TIGHTENING TORQUE in-lb180 250 325 375 500 500
TYPE KVS-AALUMINUM OKLIP Mechanical Connector For All
Combinations of Copper, Aluminum, ACSR, AAAC and 5005Three-piece,
high-conductivity, non-copper bearing aluminum alloy connector with
thick spacer and aluminum hardware. Hardware in KVS26A and KVS28A
is stainless steel. Recommended for heavy duty dissimilar metal
applications. Spacer separates conductors and provides long contact
length. Belled entrances prevent chafing, permit easier assembly of
conductors. Longer peened bolt permits swivel action for easier
installation. Neoprene ring prevents loss of shorter bolt. PENETROX
joint compound recommended with aluminum and ACSR.
CONDUCTOR RUN CATALOG NUMBERKVS26A KVS28A KVS31A KVS34A KVS40A
KVS44A
TAP ACSR, AAAC, & 5005 COPPER, & ALUM. ACSR, AAAC &
50056 - 2/0 6 - 4/0 6 - 336.4 5 - 397.5 3/0 - 715.5 3/0 - 900
COPPER, & ALUM.2 Str. - 2/0 Str. 1/0 Str. - 4/0 Str. 250 -
350 kcmil 400 - 500 kcmil 400 - 800 kcmil 500 - 1000 kcmil
RECOMMENDED TIGHTENING TORQUE in-lb180 240 300 300 300 480
AWG 4 - 2/0 10 Str. - 2/0 Str. AWG 1/0 - 4/0 10 Str. - 4/0 Str.
AWG 4/0 - 336.4 6 Str. - 350 kcmil 336.4 - 397.5 4 Str. - 500 kcmil
336.4 - 715.5 3/0 Str. - 800 kcmil 397.5 - 900 3/0 Str. - 1000
kcmil
Accommodates compressed conductors within diameter range. See
note page A-2
THESE CONNECTORS CAN ACCOMMODATE ACSR CONDUCTORS OVER ARMOR ROD
WITHIN THE DIAMETER RANGE INDICATED. APPLICATION OVER ARMOR
RODCanada: 1-800-387-6487
CATALOG NUMBERKVS26A KVS28A KVS31A KVS34A KVS40A KVS44A
CONDUCTOR RANGE BY DIAMETER MAX. RUN & MIN. RUN DIA. MIN.
TAP DIA. TAP DIA..281 .360 .565 .728 .728 .806 .116 .116 .184 .216
.470 .470 .447 .564 .681 .814 1.036 1.162
H2-1/4 3 3-1/16 3-9/16 4-1/16 4-7/8
J5/16 3/8 1/2 1/2 1/2 5/8
L
W
1-1/4 1-5/8 1-5/8 2-1/16 1-15/16 2-7/16 2-5/16 2-5/8 2-7/16
2-7/8 2-1/2 3-1/8
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products.
www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-9
TYPE QPXVERSITAP Parallel Clamp For Copper, Copperweld,
CopperweldCopperThe VERSITAP Type QPX is recommended for Tee,
Cross, Parallel, Butt and Tap connections. Range-taking, only 10
connectors required to accommodate conductor sizes from #6 Str. to
1000 kcmil. Edges are rounded for easy taping. Made of high
strength, high-conductivity copper alloy and silicon bronze DURIUM
hardware. * For various configurations, see page A-10.
Fig. 1
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375
CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C QPX3428 QPX3434
QPX442C QPX4428 QPX4434 QPX4444
COPPER CONDUCTOR RUN TAP6 Str. - 2 Str. 1 Str. - 4/0 Str. 250 -
500 kcmil 6 Str. - 2 Str. 6 Str. - 2 Str. 1 Str. - 4/0 Str. 6 Str.
- 2 Str. 1 Str. - 4/0 Str. 250 - 500 kcmil 6 Str. - 2 Str. 1 Str. -
4/0 Str. 250 - 500 kcmil 500 - 1000 kcmil
FIG. NO.
H1-1/2 2-1/16
J5/16 3/8 5/16 3/8 5/16 3/8
L1-5/16 1-13/16 1-3/8 1-3/4 2-1/16 1-3/8 1-13/16 2-1/16
2-5/8
W1-3/8 1-9/16 1-13/16 1-7/8 2-1/16 2-3/16 2-1/4 2-7/16
2-9/16
1
2-3/8 2-3/4 3 2-11/16 2-7/8 3-1/16 3-7/16
2 1 2
500 - 1000 kcmil
500
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor combinations. See note page A-2.
CONDUCTOR RUN CATALOG NUMBERQPX2C2C QPX282C QPX2828 QPX342C
QPX3428 QPX3434 QPX442C QPX4428 QPX4434 QPX4444
TAP COPPERWELD COPPER8A - 4A 3A - 3/0 V 3A - 3/0 V 4/0 EK
COPPERWELD5 SOL. - 3 #7 7 #9 - 7 #5 7 #9 - 7 #5 19 #9 - 19
#6
COPPERWELD5 SOL. - 3 #7 5 SOL. - 3 #7 7 #9 - 7 #5 5 SOL. - 3 #7
7 #9 - 7 #5 19 #9 - 19 #6 5 SOL. - 3 #7 7 #9 - 7 #5 19 #9 - 19 #6
19 #6
COPPERWELD COPPER8A - 4A 8A - 4A 3A - 3/0 V 8A - 4A 3A - 3/0 V
4/0 EK 8A - 4A 3A - 3/0 V 4/0 EK
19 #6
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-10
Mechanical
BURNDY Products
TYPE QPX-YUNIVERSAL VERSITAP Universal Parallel Clamp For Copper
and AluminumHigh copper alloy cast connector, tin-plated for use
with copper or aluminum cable. Makes parallel, tap, tee, cross or
end-to-end connections. Edges rounded for easy taping. PENETROX
joint compound recommended.
Fig. 1CONDUCTOR ALUMINUM OR COPPER RUN TAP6 Str. - 2 Str. 1/0
Str. - 4/0 Str. 1/0 Str. - 4/0 Str. 250 - 500 kcmil 750 - 1000
kcmil 6 Str. - 2 Str. 6 Str. - 2 Str. 1/0 Str. - 4/0 Str. 6 Str. -
2 Str. 1/0 Str. - 4/0 Str. 200 - 500 kcmil 750 - 1000 kcmil
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb 150 250 375 500
CATALOG NUMBERQPX2C2C-Y QPX282C-Y QPX2828-Y QPX342C-Y QPX3428-Y
QPX3434-Y QPX4444-Y
FIG. NO.1 1 2 2
H1-5/8 1-7/8 2 2-1/4 2-1/2 2-7/8 3-7/8
J5/16 3/8 5/16 3/8 1/2
L1-1/2 2 1-1/2 2 2-1/2 3-1/2
W1-5/8 1-7/8 2-1/8 2-1/8 2-1/2 2-5/8 3-1/2
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7 4, 7-5 7-6 for smaller
conductor combinations. See note page A-2.
APPLICATION VARIATIONSPARALLEL TAP CROSS
TEE SPLICE
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-11
TYPE KPASCRULUG For Copper CableHigh copper alloy tin-plated
terminal for joining a wide range of cable to equipment pads or
terminal blocks. Especially good in light industrial applications.
The tongue and body are a one-piece design. The pressure bar
equalizes pressure over the conductor and prevents the screw from
cutting into the cable.
Fig. 1STUD HOLE SIZE.10 1/4 5/16 3/8 1/2
Fig. 2RECOMMENDED TIGHTENING TORQUE in-lb12 45 180 250 375
CATALOG NUMBERKPA8C KPA4C KPA25 KPA28 KPA34
WIRE RANGE14 Sol. - 8 Str. 14 Sol. - 4 Str. 4 Str. - 1/0 Str.
1/0 Str. - 4/0 Str. 4/0 Str. - 500 kcmil
FIG. NO.1 1 2 2 2
C.38 .50 .75 .97 1.38
D.47 .59 .81 1.12 1.38
H.72 .94 1.25 1.66 2.44
K.21 .27 .33 .40 .54
L.95 1.20 1.70 2.29 3.14
N.22 .30 .41 .53 .75
T.06 .06 .10 .13 .20
NOTE: For unplated version add UNPL suffix.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-12
Mechanical
BURNDY Products
TYPE KPA-UPSCRULUG FOR COPPER CABLEHigh copper alloy terminal
for joining a wide range of cable to equipment pads or terminal
blocks. Plain copper finish.
Features and Benefits One piece design. Superior torque and pull
out performance. Convenient range taking design. Reduces catalog
numbers. One catalog number accommodates several conductor sizes.
High conductivity copper alloy. Long lasting, reliable contact.
Compact design. Easy to use. Slot Robertson screw, hex head, hex
socket bolt. No special installation tools required. Eliminates
over-torquing/potential conductor damage.
Fig. 1STUD HOLE SIZE#10 1/4
CATALOG NUMBERKPA8CUP KPA4CUP
WIRE RANGE14 Sol. 6 Str. 14 Sol. 4 Str.
FIG. NO.1
C0.38 0.50
D0.51 0.71
H0.81 1.00
K0.20 0.28
L1.01 1.28
N0.24 0.33
T0.07 0.07
HARDWARE1/4 Dia. Slot Robertson 5/16 Dia. Slot Robertson
RECOMMENDED TIGHTENING TORQUE in-lb35 45
NOTE: For tin plating drop -UP suffix and add -TP suffix
(example: KPA4CTP). For use in grounding applications with a green
screw, contact factory. Listed for grounding per UL467.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-13
TYPE KLUSCRULUG FOR COPPER CABLE OFFSET TONGUE NON-PLATEDHigh
copper alloy terminal with offset tongue for joining a wide range
of cable to equipment pads or bar. Easy to install with screwdriver
or wrench. Connector is reusable. Plain copper finish.
Features and Benefits Convenient range-taking design. Reduces
catalog numbers. One conductor accommodates several conductor
sizes. High conductivity copper alloy. Long lasting reliable
contact. Compact design. Easy to use. Reduces labor time. Slot
Robertson screw, hex head/hex socket bolt. No special installation
tools required. Eliminates over-torquing/potential conductor
damage.
Fig. 1CATALOG NUMBER CONDUCTOR
Fig. 2STUD HOLE SIZE #6 #10 1/4 1/4 3/8 5/16 3/8 3/8
Fig. 3STRIP LENGTH (IN.) 7/16 5/8 3/4 15/16 1 1-5/16 1-5/8
1-5/32
RECOMMENDED FIG. B C K L N T TIGHTENING NO. (MM/IN) (MM/IN)
(MM/IN) (MM/IN) (MM/IN) (MM/IN) TORQUE IN LBS. 3 6.4 .26 8.4 .33
11.8 .46 16.9 .63 18.0 .71 19.6 .77 25.2 1.0 29.6 1.16 8.0 .31 10.0
.39 12.0 .47 16.9 .63 19.0 .75 26.2 .99 26.2 .99 38.0 1.60 3.6 .14
6.0 .20 6.7 .26 6.5 .26 10.0 .39 8.5 .33 10.0 .39 10.0 .39 26.0
1.02 31.6 1.24 39.6 1.56 50.5 1.99 66.0 2.20 65.0 2.56 72.0 2.83
104.0 4.09 6.3 .21 5.6 .22 6.4 .25 10.8 .43 11.0 .43 13.0 .51 13.1
.52 23.0 .91 1.9 .07 1.8 .07 2.1 .08 2.7 .11 4.0 .16 3.1 .12 3.1
.12 4.5 .18 20 45 50 50 124 204 325 375
HARDWARE No. 8 - 32 Slotted Round Machine Screw 1/4 UNF Slotted
Set Screw 5/16 UNF Slotted Set Screw 3/8 UNF Slotted Set Screw 3/8
UNF Socket/Hex Screw 7/16 UNF Socket/Hex Screw 5/8 UNF Socket/Hex
Screw 5/8 UNF Socket/Hex Screw
QUANTITY/ PACKAGE 100 100 100 25 12 12 6 3
KLU25 14 Sol. 1.63 (0.64) Dia. to KLU25TP 10 Sol. 2.60 (1.02)
Dia. CU KLU35 14 Sol. 1.63 (.0641) Dia. to KLU35TP 6 Str. 4.67
(.184) Dia. CU KLU70 8 Sol. 3.28 (.129) Dia. to KLU70TP 2 Str. 7.42
(.292) Dia. CU KLU125 2 Str. 7.42 (.292) Dia. to KLU125TP 1/0 Str.
9.44 (.372) Dia. CU KLU175 4 Str. 5.89 (.232) Dia. to KLU175TP 3/0
Str. 11.94 (.470) Dia. CU KLU225 2 Str. 7.42 (.292) Dia. to
KLU225TP 4/0 Str. 13.4 (.528) Dia. CU KLU300 1/0 Str. 9.44 (.372)
Dia. to KLU300TP 350 kcmil 17.30 (.681) Dia. CU KLU400 1/0 Str.
9.44 (.372) Dia. to KLU400TP 500 kcmil 207 (.813) Dia CU
2
1
1
NOTES: Suffix -TP on catalog number denotes tin plate (example:
KLU400TP). 2 Material: Copper alloy.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-14
Mechanical
BURNDY Products
TYPE KAKA-LUG For Copper CableCompact, economical, high copper
alloy terminal for joining a wide range of cable to equipment pads
or terminal blocks.
Fig. 1CATALOG NUMBERKA8C KA4C KA25 KA25-2TC 38 KA28 KA34
Fig. 2STUD HOLE SIZE#10 1/4 3/8 3/8 3/8 1/2
Fig. 3RECOMMENDED TIGHTENING TORQUE in-lb25 45 200 200 275
375
CONDUCTOR14 Sol. - 8 Str. 14 Sol. - 4 Str. 4 Str. - 1/0 Str. 4
Str. - 1/0 Str. 1 Str. - 4/0 Str. 4/0 Str. - 500 kcmil
FIG. NO.1 2 3 2
C3/8 9/16 3/4 3/4 15/16 1-3/8
H5/8 3/4 15/16 15/16 1-1/4 2-3/32
J#12 5/16 1/2 1/2 5/8 13/16
K7/32 9/32 27/64 27/64 27/64 9/16
L13/16 1-1/8 1-11/16 2-13/16 1-15/16 2-9/16
N3/16 1/4 3/8 3/8 7/16 9/16
T3/32 7/64 1/8 1/8 3/16 9/32
Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor sizes.
TYPE EAVERSILUG For Copper CableCompact, high copper alloy
terminal for joining a wide range of cable to equipment pads or
bar. Clamping element adjustable to several angles. One-wrench
installation.
CATALOG NUMBEREA2C EA25 EA28 EA28-2N EA34 EA34-2N
CONDUCTOR8 Sol. - 2 Str. 2 Str. - 1/0 Str. 1/0 Str. - 4/0 Str.
250 - 500 kcmil
NO. OF HOLES IN PAD
C
D1-1/16 1-1/8 1-3/8 3-5/8 1-5/8 3-5/8
E 1-3/4 1-3/4
H1-3/8 1-7/16 1-3/4 2-1/4
K7/16
STUD HOLE SIZE3/8 3/8 3/8 1/2 1/2 1/2
L2-1/2 2-11/16 3-3/16 5-1/8 4 5-5/8
N13/32 7/16 17/32 5/8 13/16 5/8
T1/4 5/16 3/8
RECOMMENDED TIGHTENING TORQUE in-lb150 180 250 375
1 13/16 1 7/8 1 1-1/16 2 NEMA 1 1-3/8 2 NEMA
9/16
* N indicates NEMA standard stud holes. Listed torque values are
for maximum conductor sizes accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller conductor sizes.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products.
www.burndy.com US: 1-800-346-4175
Canada: 1-800-387-6487
BURNDY Products
Mechanical
A-15
TYPE BGBLLAY-IN QIKLUG *UL LISTED 90 C, 600 VThe Lay-In QIKLUG,
Type BGBL is manufactured from high strength 6061-T6 aluminum, and
is ideally suited for grounding and bonding applications
accommodating both copper and aluminum conductor sizes #14 AWG to
250 kcmil.
Fig. 1
Features and Benefits * UL 486B listed, AL9CU rated. For copper
and aluminum conductor combinations up to 90 C, 600 Volt
applications. UL Recognized for grounding and bonding. Ensures
reliability. Electro-tin plated. Provides low contact resistance.
Lay-in feature. Eases installation.
Fig. 2
DIMENSIONS CATALOG NUMBERBGBL-4 BGBL-1/0 BGBL-250
FIG NO.1 1 2
CONDUCTOR RANGEAWG 14 - 4 AWG 14 - 1/0 AWG 6 - 250 kcmil
C.39 [10] .63 [16] .88 [22]
D.62 [16] .80 [20] 1.18 [30]
E.48 [12] .83 [21] 1.00 [30]
H REF.79 [20] 1.16 [29] 1.72 [44]
J1/4 - 28 3/8 - 24 7/16 - 18
K DIA..22 [6] .28 [7] .28 [7]
L1.10 [28] 1.63 [41] 2.18 [55]
N.20 [5] .44 [11] .45 [11]
T.13 [3] .19 [5] .25 [6]
HEX SIZESLOT SLOT 7/32
NOTE: PEN-A PENETROX inhibitor is recommended for all aluminum
terminations.
TYPE CL50-1COPPER LAY-IN QIKLUG FOR COPPERThe Lay-In QIKLUG is
manufactured from high strength pure electrolytic copper to ensure
maximum strength and conductivity. UL467 Listed for direct burial
in earth or concrete. The open-faced design allows for fast lay-in
of the conductor without the need for cutting or breaking.
Stainless Steel Screw
Catalog NumberCL50-1 CL50-1TN*
Wire Range Copper#14 - #4 CU #14 - #4 CU
Stud Hole#10 #10
*-TN version is tin plated. Commonly used for solar panel
grounding
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-16
Mechanical
BURNDY Products
TYPES QA, QQAQIKLUG For Copper CableType QA heavy duty, compact,
high copper alloy terminal for joining a wide range of cable to
equipment pads or bar. Fast onewrench installation. Type QQA heavy
duty, high copper alloy terminal for joining cable to equipment
pads or bar. Twin clamping elements secure joint vibration and
flexing. One-wrench installation.
Type QA
Type QQA
CATALOG NUMBER* TYPE QA TYPE QQAQA8C-B QA8C-2B QA4C-B QA4C-2B
QA1C-B QA1C-2B QA26-B QA26-2B QA28-B QA28-2B QA28-2N* QA31-B
QA31-2B QA31-2N* QA34-B QA34-2B QA34-4B QA34-2N* QA40-B
QA40-2N*
CONDUCTOR COMMERCIAL NAVY14 Sol. - 8 Str. 4 - 14 23 - 40 50 -
75
NO. OF HOLES IN PAD1 2 1 2 1 2 1 2 1 2 2 NEMA 1 2 2 NEMA 1 2 4 2
NEMA 1 2 NEMA 4 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA
C9/16
D
E&F
H
K
STUD HOLE SIZE#10 1/4 5/16 3/8
L1-3/8 2 1-7/16 2 1-3/4 2-9/16 2 3 2-1/4 3-9/16 4-5/16 2-11/36
3-3/8 4-7/16 3-3/16 3-9/16 3-1/2 4-11/16 3-11/16 4-14/16 3-15/16 5
4-3/8 5-1/4
LL2-5/16 3 2-3/8 2-15/16 2-13/16 3-5/8 3-3/16 4-3/16 3-9/16
5-5/8 4-1/8 5-7/8 4-7/8 6-9/32 7-3/32 7-1/8
N9/32 5/16 5/16 11/32
T5/32 3/16
RECOMMENDED TIGHTENING TORQUE in-lb75 110 150
QQA4C QQA4C-2 QQA1C QQA1C-2 QQA26 QQA26-2 QQA28 QQA28-2N*
QQA31
8 Str. - 4 Str. 4 Str. - 1 Str.
5/8
1/0 Str. - 2/0 Str. 100 - 125 3/0 Str. - 4/0 Str. 150 - 200
13/16 1
250 - 350 kcmil 250 - 350 QQA31-2N* QQA34 400 - 500 kcmil 400 -
500 QQA34-2N* QQA40-2N* QQA40-4N 600 - 800 kcmil 650 - 800
1-3/16 1-3/8 1-7/8 1-3/8 1-5/8 3 1-7/8
9/16 11/16 1-1/4 5/8 7/32 5/8 3/4 1-3/16 5/8 9/32 3/4 1 1-9/16
7/8 11/32 1 1-3/16 1-15/16 1 13/32 1-1/16 2 1 1-5/16 3-1/8 1-3/4
9/16 1-3/8 17/32 1-31/32 1 1-11/16 7/16 3 1-3/4 9/16 1-5/8 17/32 2
13/32 1 2 1-15/16 7/16 3-3/32 1-3/4 9/16 1-7/8 11/16 2-7/16 3 1-3/4
9/16 11/16 2-3/4 3-1/8 9/16 13/16 9/16
7/32 7/16 17/32 7/16 5/8 11/16 7/16 5/8 13/16 7/16 7/16 5/8
27/32 5/8 1 5/8 1-1/16 5/8 1/2 9/16 600 1/4 180 250
1/2 3/8 1/2 3/8 1/2 5/8 1/2 5/8 1/2 3/4 1/2
5/16
325
5/16
375
3/8 500
QA44-B QA44-2N* QQA44-2N QA44-4N* QA46-B QA46-2N*
850 - 1000 kcmil 1100 - 1500 kcmil
1000 1300
2 3 1-3/4 3 3-1/16 2-1/8 2-1/8 3 1-3/4
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-17
TYPE Q2AQIKLUG For Copper CableCompact, high copper alloy
terminal for joining two cables to equipment pads or bars. Each
element accommodates a wide range of cable. One-wrench
installation.
CATALOG NUMBER*Q2A1C-2 Q2A26-2N Q2A28-2N Q2A28-4N Q2A31-2N
Q2A31-4N Q2A34-2N Q2A34-4N Q2A40-2N Q2A40-4N Q2A44-4N Q2A46-4N
CONDUCTOR4 Str. - 1 Str. 1/0 Str. - 2/0 Str. 3/0 Str. - 4/0 Str.
250 - 350 kcmil 400 - 500 kcmil 600 - 800 kcmil 850 - 1000 kcmil
1100 - 1500 kcmil
NO. OF HOLES IN PAD2 2 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4
NEMA 2 NEMA 4 NEMA 4 NEMA
C1-1/2 1-5/8 1-7/8 3 2-3/8 3 2-1/2 3 3 3-1/4 3-1/2
D1-7/8
E&F1 3/4
H1-1/16 1-3/16 1-3/8
K7/16
STUD HOLE SIZE3/8
L2-7/8 4-3/16 4-3/8 4-1/2
N7/16
T7/32 7/32 1/4 5/16
W1-13/16 1-15/16 1-15/16 2-1/8 2-1/8 3 3 3-3/4 3-3/4 4-11/32
4-11/32 5
RECOMMENDED TIGHTENING TORQUE in-lb 150 180 250 325 375 500
600
3-1/8 1-3/4
1-11/16 2 2-7/16 9/16 1/2
4-11/16 5 5-1/4 5-1/2
5/8
3/8 7/16 1/2 11/16
3-1/4
2-3/4 3-1/8
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
TYPE Q3AQIKLUG For Copper CableCompact, high copper alloy
terminal for joining three cables to equipment pads or bar. Each
element accommodates a wide range of cable. One-wrench
installation.
CATALOG NUMBER*Q3A28-2N Q3A28-4N Q3A31-2N Q3A31-4N Q3A34-2N
Q3A34-4N Q3A40-4N Q3A44-4N Q3A46-4N
CONDUCTOR3/0 Str. - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 600
- 800 kcmil 850 - 1000 kcmil 1100 - 1500 kcmil
NO. OF HOLES IN PAD2 NEMA 4 NEMA 2 NEMA 4 NEMA 2 NEMA 4 NEMA 4
NEMA 4 NEMA
C1-7/8 3 2-3/8 3 2-1/2 3 3-1/4 3-1/2
D
E&F
H1-3/8
K
STUD HOLE SIZE
L4-5/16 4-3/8 4-7/16
N
T1/4 5/16
W3-3/16 4-1/16 4-9/16 5-13/16 6-5/8 7-7/8
RECOMMENDED TIGHTENING TORQUE in-lb250 325 375 500 600
3-1/8 1-3/4
1-11/16 1-15/16 2-7/16 2-3/4 3-1/8 9/16 1/2
4-3/4 5 5-1/4 5-1/2
5/8
3/8 7/16 1/2 11/16
3-1/4
* N indicates NEMA standard stud holes.
US: 1-800-346-4175
www.burndy.com
Canada: 1-800-387-6487
A-18
Mechanical
BURNDY Products
TYPE QBQIKLUG For Copper CableCompact, high copper alloy side
entrance terminal for joining a range of cable at right angles to
terminal blocks. One-wrench installation.
CATALOG NUMBER*QB8C QB4C QB1C QB26 QB28 QB31-2N
CONDUCTOR14 Sol. - 8 Str. 8 Str. - 4 Str. 4 Str. - 1 Str. 1/0
Str. - 2/0 Str. 3/0 Str. - 4/0 Str. 250 - 350 kcmil
NO. OF HOLES IN PAD1 1 1 1 1 2 NEMA
C9/16 11/16 13/16 1 13/16
D9/16 27/32 13/16 1 1-1/16 3-1/4
E 1-3/4
H7/8 13/16 1 1-1/32 1-5/16 1-11/16
K7/32 9/32 13/32 9/16
STUD HOLE SIZE#10 1/4 3/8 1/2
L1-1/8 1-3/8 1-1/2 1-13/16 2-1/16 4-1/2
N9/32 11/32 7/16 17/32 5/8
T5/32 1/4 7/32 1/4 5/16
RECOMMENDED TIGHTENING TORQUE in-lb 75 110 150 180 250 325
N indicates NEMA standard stud holes.
TYPE Q2BQIKLUG For Copper CableCompact, high copper alloy
terminal for joining two cables at right angles to a single
terminal block. Each element accommodates a range of cable.
One-wrench installation.
CATALOG NUMBER*Q2B28-2N Q2B31-2N Q2B40-4N
CONDUCTOR3/0 Str. - 4/0 Str. 250 - 350 kcmil 600 - 800 kcmil
NO. OF HOLES IN PAD2 NEMA 2 NEMA 4 NEMA
C1-7/8 2-3/8 3
D
E&F
H
K9/16
STUD HOLE SIZE3/8 1/2 1
L5-3/16 5-7/8 6-11/16
N5/8
T1/4 5/16 7/16
RECOMMENDED TIGHTENING TORQUE in-lb250 325 500
3-1/8 1-3/4 1-3/8 3-3/16 1-11/16 1-3/8 3-1/16 1-3/8 2-5/16
N indicates NEMA standard stud holes. All 4N items See note page
A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-19
TYPE QDAQIKLUG For Copper CableCompact, high copper alloy
terminal for joining a wide range of cable to equipment studs.
Provides low contact resistance when gripped between two contact
nuts. Onewrench installation.
CATALOG NUMBERQDA8C QDA4C QDA1C QDA26 QDA28 QDA31 QDA34
QDA40
CONDUCTOR COMMERCIAL NAVY14 Sol. - 8 Str. 8 Str. - 4 Str. 4 Str.
- 1 Str. 1/0 Str. - 2/0 Str. 3/0 Str. - 4/0 Str. 250 - 350 kcmil
400 - 500 kcmil 600 - 800 kcmil 3 - 14 23 - 40 50 - 75 100 - 125
150 - 200 250 - 350 400 - 500 650 - 800
C1 1-1/4 1-1/2 1-7/8 2-1/8
H11/16 3/4 1 1-3/16 1-5/16 1-11/16 2 2-5/16
K7/16 9/16 11/16 13/16 1-1/16
STUD HOLE SIZE3/8 1/2 5/8 3/4 1
L1-7/8 2-3/16 2-1/2 2-5/8 3 3-5/8 4-3/16
T3/16 7/32 9/32 5/16 3/8
RECOMMENDED TIGHTENING TORQUE in-lb75 110 150 180 250 325 375
500
TYPE QR QIKLINKSPLICE OR REDUCER For Copper Cable to CableHigh
copper alloy splicer/reducer for joining a range of cable end to
end. Neat, compact easy to tape installation. One-wrench
installation.
CATALOG NUMBERQR4C QR1C QR26 QR28 QR31 QR34 QR40See note page
A-2.
CONDUCTOR EITHER SIZE8 Str. - 4 Str. 4 Str. - 1 Str. 1/0 Str. -
2/0 Str. 3/0 Str. - 4/0 Str. 250 - 350 kcmil 400 - 500 kcmil 600 -
800 kcmil
H3/4 1-1/16 1-3/16 1-3/8 1-11/16 1-15/16 2-7/16
L1-11/16 1-15/16 2-1/8 2-3/8 2-5/8 3-1/16 3-5/8
W5/8 11/16 13/16 1 1-1/4 1-7/16 1-7/8
RECOMMENDED TIGHTENING TORQUE in-lb110 150 180 250 325 375
500
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-20
Mechanical
BURNDY Products
TYPE VTVARITAP T-CONNECTOR For Copper Cable to CableHigh copper
alloy T-connector for cable run, cable tap. V-bolt clamping
elements accommodate large range of cable and are particularly
suited for extra flexible cable. One-wrench installation.
CATALOG NUMBERVT2C2C VT2525 VT2825 VT2828 VT3025 VT3030 VT3425
VT3428 VT3430 VT3434 VT4040 VT4425 VT4428 VT4834
CONDUCTOR RUN8 Sol. - 2 Str. 6 Sol. - 1/0 Str. 1/0 Str. - 4/0
Str. 1/0 Str. - 300 kcmil
TAP8 Sol. - 2 Str. 6 Sol. - 1/0 Str. 6 Sol. - 1/0 Str. 1/0 Str.
- 4/0 Str. 6 Sol. - 1/0 Str. 1/0 Str. - 300 6 Sol. - 1/0 Str. 1/0
Str. - 4/0 Str. 1/0 Str. - 300 300 - 500 500 - 800 6 Sol. - 1/0
Str. 1/0 Str. - 4/0 Str. 300 - 500
H1-5/16 1-5/8 1-7/8
L2-5/16 2-5/8 3-1/8 3-1/16 3-3/8 3-5/16 3-11/16 3-1/2 3-5/8
3-3/4 4-1/2 4-5/16 4-1/8 5-1/4
W1-5/16 1-7/16 1-1/4 1-11/16 1-3/8 1-15/16 1-1/2 1-11/16 1-15/16
2-1/4 2-5/8 2 2 5
RECOMMENDED TIGHTENING TORQUE in-lb RUN TAP275 385 250 250 325
325 375 375 375 375 500 500 500 600 275 385 385 250 385 325 385 250
325 375 500 385 250 375
300 - 500 kcmil 500 - 800 kcmil 750 - 1000 kcmil 1500 - 2000
kcmil
2-5/16 2-9/16 2-7/8 4-1/4
See note page A-2
TYPE E-C-GTRANSFORMER TAP ADAPTER For CopperMulti-tap,
range-taking cast copper alloy connector designed to take 2, 3 or 4
conductors from a single secondary transformer outlet.
CATALOG NUMBERE2C34G1 E3C34G1 E4C34G1
NO. OF CONDUCTORS2 3 4
CONDUCTOR A SIZE DIA.1/0 Sol. - 500 kcmil .78
D
H
J
L
W
RECOMMENDED TIGHTENING TORQUE in-lb480
3-1/2 3-3/4 2-7/8 1/2-13 6-1/4 5-1/4 6-7/8
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-21
TYPE VA, VVAVARILUG For Copper CableHigh copper alloy terminal
for joining a wide range of cable to equipment pads or bar.
Particularly suitable for use on extra flexible cable. One-wrench
installation. Type VVA, twin elements secure joint against
vibration and flexing. Particularly recommended for use on extra
flexible cables. One-wrench installation.
Type VA
Type VVA
CATALOG NUMBER* TYPE VA TYPE VVAVA2C VA25 VA28 VA28-2N VA30
VA30-2N VA34 VA34-2N VA34-4N VA40 VA40-2N VA40-4N VVA2 VVA25 VVA28
VVA28-2N VVA30 VVA30-2N VVA34 VVA34-2N VVA34-4N VVA40 VVA40-2N
VVA40-4N
CONDUCTOR8 Sol. - 2 Str. 6 Sol. - 1/0 Str. 1/0 Str. - 4/0 Str.
1/0 Str. - 300 kcmil 300 - 500 kcmil
NO. OF HOLES IN PAD1 1 2 NEMA 1 2 NEMA 1 2 NEMA 4 NEMA 1 2 NEMA
4 NEMA
C
D
E&F
H
K
STUD HOLE SIZE3/8 1/2 3/8 1/2 5/8 1/2
L2-3/4 2-7/8 2-7/8 4-15/16 3-1/4 5-3/16 3-13/16 5-3/8 5-3/8
4-1/2 5-13/16 5-13/16
LL4-1/16 4-5/16 4-1/8 6-3/6 4-5/8 6-9/16 5-5/16 6-7/8 6-7/8
6-3/8 7-11/16 7-11/16
N
T
RECOMMENDED TIGHTENING TORQUE in-lb275 385 250 325 375
500 - 800 kcmil
13/16 1-1/4 7/8 1-5/16 1-1/2 1-1/16 3-1/2 1-5/8 1-1/8 3-9/16 2
1-3/8 3-5/8 3 3-5/8 2-5/16 1-5/8 3-5/8 3 2-5/8
1-1/2 7/16 1-7/8 7/16 2-1/4 1-3/4 9/16 7/16 2-3/16 1-3/4 9/16
1-3/4 3-11/32 1-3/4 11/16 1-3/4 2-7/8 9/16 1-3/4 9/16
13/32 1/4 7/16 17/32 5/8 5/16 5/8 5/8 13/16 5/8 5/8 3/8 15/16
5/8 5/8
500
N indicates NEMA standard stud holes. All 4N items See note page
A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-22
Mechanical
BURNDY Products
TYPE HFB-P1BAR CLAMP ASSEMBLY COMPONENTS For Copper BarTo build
your own high strength clamp assembly for multiple flat bar using
type HFBP1 bar clamps and clamping hardware, the following tables
have been provided. The clamp assembly eliminates the need for
drilling the flat bar and is used in indoor and outdoor
applications.
BAR CLAMP BAR CATALOG RUN TAP NUMBER A AAHFB22P1 HFB33P1 HFB42P1
HFB44P1 HFB63P1 HFB66P1 HFB88P1 2.00 3.00 4.00 4.00 6.00 6.00 8.00
2.00 3.00 2.00 4.00 3.00 6.00 8.00
ONE CLAMP HALF J BOLT DIA. L3/8 3/8 3/8 1/2 1/2 5/8 3/4 4.38
4.38 5.75 5.75 7.75 8.12 10.50
W4.38 4.38 5.75 5.75 4.75 8.12 10.50
Z* * * * * * *
RECOMMENDED TIGHTENING TORQUE in-lb240 240 240 480 480 660
1990
*Z=Space between the bar clamp contact surfaces
COPPER BUS BAR WIDTH (INCHES) RUN-A TAP-AA2 3 4 4 6 6 8 2 3 2 4
3 6 8
BAR CLAMP ASSEMBLY COMPONENTS SILICON BRONZE CLAMPING HARDWARE
BAR CLAMP QTY. CAT. NO.2 2 2 2 2 2 2 HFB22P1 HFB33P1 HFB42P1
HFB44P1 HFB63P1 HFB66P1 HFB88P1
BOLTS QTY.4 4 4 4 4 4 4
NUTS CAT. NO.38 X (*) HEB 38 X (*) HEB 38 X (*) HEB 50 X (*) HEB
50 X (*) HEB 62 X (*) HEB 75 X (*) HEB
QTY.4 4 4 4 4 4 4
CAT. NO.38CHEN 38CHEN 38CHEN 50CHEN 50CHEN 62CHEN 75CHEN
SPLIT LOCK WASHERS QTY. CAT. NO.4 4 4 4 4 4 4 38SW 38SW 38SW
50SW 50SW 62SW 75SW
Ordered separately from BURNDY. * See table below when ordering
assembly clamping bolts to specify correct bolt length in Cat.
#.
CLAMP NUMBERHFB22P1 HFB33P1 HFB42P1 HFB44P1 HFB63P1 HFB66P1
HFB88P1
J BOLT DIA.3/8 (-16) 3/8 (-16) 3/8 (-16) 1/2 (-13) 1/2 (-13) 5/8
(-11) 3/4 (-10)
WHEN Z = 1.253.00 3.00 3.00 3.25 3.25 3.50 3.75
WHEN Z = 1.503.25 3.25 3.25 3.50 3.50 4.00 4.00
BOLT LENGTH WHEN WHEN Z = 1.75 Z = 2.003.50 3.50 3.50 3.75 3.75
4.00 4.50 4.00 4.00 4.00 4.00 4.00 4.50 4.50
WHEN Z = 2.254.00 4.00 4.00 4.50 4.50 4.50 5.00
WHEN Z = 2.504.50 4.50 4.50 4.50 4.50 5.00 5.00
WHEN Z = 2.754.50 4.50 4.50 5.00 5.00 5.00 5.50
WHEN Z = 3.005.00 5.00 5.00 5.00 5.00 5.50 5.50
NOTE: When ordering assembly bolts specify correct bolt length
in catalog number as indicated in table.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-23
TYPE HFB-NBAR CLAMP TAP PAD ADAPTER For Copper BarHigh
conductivity copper, tap pad adapter provides a NEMA drilled
contact pad when assembled to the HFB-P1 clamps. Tap connections
can be made from copper bus bar(s) without drilling, by bolting
standard mechanical or compression terminal pads directly to the
pre-drilled tap pad
Fig. 1 Fig. 2CATALOG NUMBERHFB33-4N HFB44-4N HFB66-6N
FIG. NO.1 1 2
A-C3.00 4.00 6.00
E&F1.75 1.75 1.75
L7.00 9.12 11.31
N.62 1.12 1.12
USE WITH H CLAMP CATALOG NUMBER HFB33P1 HFB44P1 HFB66P1
H Clamp (two required per assembly) and hardware (asshown) not
included with bar clamp tap pad, order separately.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-24
Mechanical
BURNDY Products
TYPES KA-U, KKA-UUNIVERSAL TERMINAL (One Conductor) For Aluminum
and Copper ConductorsThese dual-rated one-conductor lugs are
constructed from high strength aluminum alloy and electro
tin-plated to provide low contact resistance.
Fig. 1
Fig. 2
AL9CU
Fig. 3
Fig. 4
CATALOG NUMBER*KA6U KA2U KA25U KA26U KA29U KA30U KA31U KA34U
KA36U KA40U KA44U KKA31U-2N KA36U-2N KA40U-2N KA44U-2N
FIG. NO.1 1 1 2 2 2 2 2 2 2 2 3 4 4 4
WIRE RANGE ALUMINUM OR COPPER14 Str. - 6 Str. 14 Str. - 2 Str.
14 Str. - 1/0 Str. 6 Str. - 2/0 Str. 6 Str. - 250 kcmil 6 Str. -
300 kcmil 6 Str. - 350 kcmil 4 Str. - 500 kcmil 2 Str. - 600 kcmil
300 - 800 kcmil 500 - 1000 kcmil 6 Str. - 350 kcmil 2 Str. - 600
kcmil 300 - 800 kcmil 500 - 1000 kcmil
STUD HOLE SIZE1/4
D.63 .63 .81 .81 .94 .94 1.03 1.50 1.72 1.69 1.69 3.16 3.22 3.03
3.03
L1.06 1.16 1.50 1.47 2.00 2.00 2.25 2.81 3.19 3.38 3.38 5.50
4.69 4.75 4.75
DIMENSIONS ** N W E.25 .31 .44 .47 .50 .50 .88 .88 .78 .88 .88
.63 .63 .63 .63 .50 .50 .63 .63 1.00 1.00 1.13 1.51 1.50 1.75 1.75
1.25 1.50 1.75 1.75 1.75 1.75 1.75 1.75
T.09 .10 .19 .19 .25 .25 .25 .31 .44 .50 .50 .38 .44 .50 .50
** H.50 .55 .80 .80 1.13 1.12 1.25 1.58 1.56 1.94 1.94 1.50 1.57
1.94 1.94
RECOMMENDED TIGHTENING TORQUE in-lb45 50 50 120 275 275 375 500
500 500 600 375 500 500 600
5/16 3/8 1/2
1/2
* N indicates NEMA standard stud holes. Listed torque values are
for maximum conductor sizes accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller conductor sizes. ** Maximum dimension.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-25
TYPE K2A-UUNIVERSAL TERMINAL (Two Conductor) For Aluminum and
Copper ConductorsThese dual-rated two-conductor lugs are
constructed from high strength aluminum alloy and electro
tin-plated to provide low contact resistance.
Fig. 1
Fig. 2
AL9CU
Fig. 3
CATALOG NUMBER*K2A25U K2A26U K2A29U K2A31U K2A36U K2A40U K2A44U
K2A31U-2N K2A36U-2N K2A40U-2N K2A44U-2N
FIG. NO.1 2 2 2 2 2 2 3 3 3 3
WIRE RANGE ALUMINUM OR COPPERTwo: 14 Str. - 1/0 Str. Two: 14
Str. - 2/0 Str. Two: 6 Str. - 250 kcmil Two: 4 Str. - 350 kcmil
Two: 2 Str. - 600 kcmil Two: 300 - 800 kcmil Two: 500 - 1000 kcmil
Two: 6 Str. - 350 kcmil Two: 2 Str. - 600 kcmil Two: 300 - 800
kcmil Two: 500 - 1000 kcmil
STUD HOLE SIZE1/4 3/8 1/2 5/8
D.81 .81 1.50 1.69 1.75 1.66 1.66 3.00 3.22 3.03 3.03
L1.47 1.47 2.56 2.88 3.20 3.38 3.50 4.50 4.69 4.75 4.75
DIMENSIONS ** N W E.44 .44 .50 .88 .63 .88 .88 .63 .63 .63 .63
1.13 1.25 1.66 1.94 2.41 3.19 3.52 2.31 2.41 3.19 3.19 1.75 1.75
1.75 1.75
T.19 .19 .25 .25 .44 .50 .50 .31 .44 .50 .50
** H.79 .79 1.20 1.25 1.58 1.94 1.94 1.38 1.56 1.94 1.94
RECOMMENDED TIGHTENING TORQUE in-lb50 50 275 275 375 375 375 275
375 375 375
1/2
* N indicates NEMA standard stud holes. Listed torque values are
for maximum conductor sizes accommodated. Consult UL486 Tables 7-4,
7-5, 7-6 for smaller conductor sizes. ** Maximum dimension.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-26
Mechanical
BURNDY Products
TYPES K3A-U, KK3A-UUNIVERSAL TERMINAL (Three Conductor) For
Aluminum and Copper ConductorsDual-rated three-conductor lugs are
constructed from high strength aluminum alloy and electro
tin-plated to provide low contact resistance.
Fig. 1
Fig. 2
AL9CU
Fig. 3
CATALOG NUMBER*K3A2U-2* K3A25U-2* K3A26U-2N K3A27U-2N K3A29U-2N
K3A31U-2N K3A36U-2N KK3A36U-2N KK3A40U-2N KK3A44U-2N
FIG. NO.1 1 3 3 3 3 3 2 2 2
WIRE RANGE ALUMINUM OR COPPERThree: 14 Str. - 2 Str. Three: 14
Str. - 1/0 Str. Three: 14 Str. - 2/0 Str. Three: 6 Str. - 3/0 Str.
Three: 6 Str. - 250 kcmil Three: 6 Str. - 350 kcmil Three: 2 Str. -
600 kcmil Three: 2 Str. - 600 kcmil Three: 300 - 800 kcmil Three:
500 - 1000 kcmil
K11/32 7/16
STUD HOLE SIZE5/16 3/8
D1.63 2.09 3.06 3.00 3.00 3.52 3.22 3.00 3.03 3.34
L2.19 2.91 3.75 3.88 4.00 4.31 4.69 5.63 5.69 6.19
DIMENSIONS N W E.34 .34 .63 .63 .63 .63 .63 .56 .63 .63 1.59
1.94 1.95 2.81 2.81 3.00 3.63 4.22 4.81 4.75 .88 1.00
T.19 .25 .19 .31 .31 .31 .44 .44 .50 .56
H.62 .88 1.79 1.12 1.19 1.38 1.56 1.69 1.94 1.88
RECOMMENDED TIGHTENING TORQUE in-lb50
275
9/16
1/2
1.75
375
* Slotted screw. ** N indicates NEMA standard stud holes. Listed
torque values are for maximum conductor sizes accommodated. Consult
UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N
items See note page A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-27
TYPES K3A-U, KK3A-U(Continued)
AL9CU
Fig. 1
Fig. 2
Fig. 3
Fig. 4
CATALOG NUMBER**K3A2U-4* K3A25U-4* K3A27U-4N K3A29U-4N K3A31U-4N
K3A36U-4N K3A40U-4N KK3A36U-4N KK3A40U-4N KK3A44U-4N
FIG. NO.3 3 3 3 3 3 3 4 4 4
WIRE RANGE ALUMINUM OR COPPERThree: 14 Str. - 2 Str. Three: 14
Str. - 1/0 Str. Three: 6 Str. - 3/0 Str. Three: 6 Str. - 250 kcmil
Three: 6 Str. - 350 kcmil Three: 2 Str. - 600 kcmil Three: 300 -
800 kcmil Three: 2 Str. - 600 kcmil Three: 350 - 800 kcmil Three:
500 - 1000 kcmil
K11/32 7/16
STUD HOLE SIZE5/16 3/8
D1.63 2.09 3.00 3.00 3.00 3.22 3.03 3.00 3.34 3.34
L2.19 2.91 3.88 4.00 4.31 4.69 4.75 5.63 6.19 6.19
DIMENSIONS N W E.34 .34 1.59 1.94 2.81 2.81 3.00 3.63 4.81 4.22
5.34 4.75 .88 1.00
T.19 .25 .31 .31 .31 .44 .50 .44 .56 .56
H.62 .88 1.12 1.19 1.38 1.56 1.94 1.69 1.88 1.88
RECOMMENDED TIGHTENING TORQUE in-lb50 275
9/16
1/2
.63
1.75
375 275 375
* Slotted screw ** N indicates NEMA standard stud holes. Listed
torque values are for maximum conductor sizes accommodated. Consult
UL486 Tables 7-4, 7-5, 7-6 for smaller conductor sizes. All 4N
items See note page A-2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-28
Mechanical
BURNDY Products
TYPES K4A-U, KK4A-UUNIVERSAL TERMINAL (Four Conductor) For
Aluminum and Copper ConductorsThese dual-rated four conductor lugs
are constructed from high strength aluminum alloy and electro
tin-plated to provide low contact resistance.
Fig. 1
Fig. 2
AL9CU
CATALOG NUMBER*K4A29U-4N K4A31U-4N KK4A36U-4N KK4A40U-4N
FIG. NO.1 1 2 2
WIRE RANGE ALUMINUM OR COPPERFour: 6 Str. - 250 kcmil Four: 6
Str. - 350 kcmil Four: 2 Str. - 600 kcmil Four: 300 - 800 kcmil
STUD HOLE SIZE1/2
D3 3 3.34 3
L4 4.31 5.63 6.19
DIMENSIONS N W E.63 3.69 5.04 5 6 1.75
T.31 .31 .44 .56
H1.19 1.38 1.69 1.88
RECOMMENDED TIGHTENING TORQUE in-lb275 375
* N indicates NEMA standard stud holes. All 4N items See note
page A-2
TYPES K11A-U, K21A-U, K22A-UUNIVERSAL TERMINAL For Aluminum and
Copper ConductorsDual-rated panelboard lugs are constructed from
high strength extruded aluminum alloy and electro tin-plated to
provide low contact resistance.
Fig. 2 Fig. 1
Fig. 3
Fig. 4
Fig. 5
AL9CU
CATALOG NUMBERK11A30U K11A34U-2 K11A36U-2 K21A36U-2 K22A36U-2
K11A39U-2 K22A39U-2
FIG. NO.1 2 3 4 5 3 5
WIRE RANGE ALUMINUM OR COPPERTwo: 6 Str. - 300 kcmil Two: 4/0
Str. - 500 kcmil Two: 2 Str. - 600 kcmil Three: 2 Str. - 600 kcmil
Four: 2 Str. - 600 kcmil Two: 1/0 Str. - 750 kcmil Four: 1/0 Str. -
750 kcmil
STUD HOLE SIZE5/16 1/4
D.94
L3.00 2.91
DIMENSIONS N W E.47 .25 1.00 1.44 1.50 2.50 2.50 1.69 3.06
.69
T.31 .63
H2.00 2.38
RECOMMENDED TIGHTENING TORQUE in-lb275
3/8
2.31
4.91
.38
1.38
.75
3.00
375
Listed torque values are for maximum conductor sizes
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
conductor sizes.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-29
TYPE KAU-KITTRANSFORMER LUG KITThese dual-rated lugs are
constructed from high strength aluminum alloy and electro tinplated
to provide low contact resistance. Lugs and mounting hardware
packaged together in these kits.
Features and Benefits UL listed AL9CU dual rated set screw
terminals and CSA certified. Ensure the transformer feeders and
taps are terminated properly. Plated steel cap screws and hex nuts
with captive conical washers or individual Belleville washers.
Terminal to bus connections are made using proper hardware
resulting in true torque to pressure performance. Compensates for
dissimilar metal expansion and contraction.
Hardware packed in plastic bag. No lost hardware prior to
installation. Larger 800 kcmil lugs in KIT3 and KIT4. Accommodates
common 750 kcmil tap conductors in larger transformers.
CATALOG NUMBERKAU-KIT1 KAU-KIT2 KAU-KIT3 KAU-KIT4
TRANSFORMER KVA RATING15 - 37.5 15 - 45 50 - 75 75 - 112.5 100 -
167 150 - 300 400 - 500 1 3 1 3 1 3 3
TERMINALS CATALOG QTY. NUMBER8 4 12 6 7 15 KA2U KA29U KA29U
K2A31U K2A40U K2A40U
WIRE RANGE ALUMINUM OR COPPER#14 - 2 #6 - 250 kcmil #6 - 250
kcmil #6 - 350 kcmil 300 - 800 kcmil 300 - 800 kcmil
QTY.8 8 8 5 6 7 4
BOLT SIZE1/4-20 3/4 HH
HARDWARE QTY. NUT8 16 11 11 1/4 1/4 20 HN 20 HN
QTY. 22 11 22 11
WASHERCaptive to Nut Captive to Nut 1/2 FW 1/2 Belleville 1/2 FW
1/2 Belleville
1/4-20 3/4 HH 1/4-20 2 HH 1/2-13 3 HH 1/2-13 2-1/2 HH 1/2-13 2
1/2-13 2-1/2
1/2-13 HN 1/2-13 HN
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-30
Mechanical
BURNDY Products
TYPE AMSDUAL RATED SPLICER/REDUCER For Copper and Aluminum
CableAll splicer/reducers are dual rated for use with aluminum and
copper conductors and are constructed from high strength, tin
plated aluminum. PENTROX oxide inhibiting joint compounds are
recommended for all aluminum applications.
Features and Benefits All connectors are tin-plated. Provide low
contact resistance and prevents galvanic corrosion. Connectors
feature rounded bottoms. Facilitates taping. Solid center barrier.
Prevents contact of dissimilar metals. Large screw diameters.
Ensures greater surface contact with wires for maximum pullout
force. Large cable ranges. Each splice is also an effective
reducing connector.
CATALOG NUMBERAMS-2* AMS-0* AMS-4/0 AMS-250 AMS-350 AMS-500
AMS-750 AMS-1000
WIRE RANGE MAX. MIN.AWG 2 AWG 1/0 AWG 4/0 250 kcmil 350 kcmil
500 kcmil 750 kcmil 1000 kcmil AWG 14 AWG 14 AWG 6 AWG 6 AWG 6 AWG
3/0 250 kcmil 500 kcmil
L1-19/32 1-29/32 2-5/16 4-3/32 4-11/32 4-25/32 6-1/16
8-11/16
W9/16 3/4 1 1 1 1-1/4 1-7/16 1-21/32
H19/16 3/4 1-3/32 1-3/32 1-3/32 1-3/8 1-5/8 1-7/8
H2 MAX..79 .86 1.28 1.29 1.30 1.48 1.98 2.34
NO. OF SCREWS2 2 2 4 4 4 4 6
SCREW DIA.3/8 7/16 9/16 5/8 11/16 13/16 15/16 1-1/8
HEX SIZES S 5/16 5/16 5/16 3/8 1/2 9/16
* Slotted Screws. H2 measured with maximum conductors, reference
only. Complies with NFPA 78-86.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-31
TYPE AGSKITABOVE GRADE SPLICE KITS For all Aluminum or
Copper/Aluminum CombinationsType AGS Above Grade Splice Kit
consists of a standard AMS splice/reducer and a heavy wall
heat-shrink sleeve. The AMS Splice is dual rated for use with
aluminum and copper conductors and are constructed from high
strength, tin plated aluminum that provides low contact resistance
and reduces the effects of galvanic corrosion. Connector is
installed with common installation tools. The heavy wall heat
shrink sleeve is lined with adhesive material, providing a positive
seal against moisture egress. Heat shrink sleeve is installed with
standard propane torch, or electric heat gun.
Fig. 1
Fig. 2
Catalog Number AGSKIT2 AGSKIT250
Figure Number 1 2
Wire Range Maximum Minimum 2 8 250 1
TYPE UGSKITWATERTIGHT/ UNDERGROUND SPLICE KITS For all Aluminum
or Copper/Aluminum CombinationsType UGS Watertight Underground
Splice Kit consists of a standard AMS splice/reducer and two heavy
wall heat-shrink sleeves. The AMS Splice is dual rated for use with
aluminum and copper conductors and are constructed from high
strength, tin plated aluminum that provides low contact resistance
and reduces the effects of galvanic corrosion. Connector installed
with common installation tools. Both heavy wall heat shrink sleeves
are lined with adhesive material, providing a watertight splice
that can withstand abrasions that may occur during direct burial
applications. Heat shrink sleeve installed with standard propane
torch, or electric heat gun.
Fig. 1
Fig. 2
Catalog Number UGSKIT2* UGSKIT250*
Figure Number 1 2
Wire Range Maximum Minimum 2 8 250 1
*UL486D Listed for Direct Burial
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-32
Mechanical
BURNDY Products
TYPE UGSKIT8UF DIRECT BURIAL SPLICE KITType UGS UF Splice Kit
consists of a UF splice connector and a heavy wall heatshrink
sleeve. The UF splice connector can accommodate up to four UF
conductors and is installed with common installation tools. The
heavy wall heat shrink sleeve is lined with an adhesive material,
providing a watertight splice that can withstand abrasions that may
occur during direct burial applications. Heat shrink sleeve
installed with standard propane torch, or electric heat gun.
Catalog Number UGSKIT8**UL486D Listed for Direct Burial.
Wire Range Copper 8 AWG 14 AWG
TYPE UGS350ULDBIN-LINE SPLICE/REDUCER For Direct Burial
Features and Benefits EPDM rubber covered 6061-T6 aluminum
connector. Dual rated AL9CU for copper or aluminum conductor. UL
Listed and CSA Certified for Direct Burial. Broad range taking
capability. Low installation cost.
CATALOG NUMBERUGS350ULDB
WIRE RANGEAWG 12 - 350 kcmil
LENGTH In. [mm]8.50 [216]
HEIGHT In. [mm]2.81 [71.4]
HEX SIZE5/16
TORQUE (In. Lbs.)350
Dimensions in brackets [ ] are in millimeters.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-33
TYPE QGFLBARTAP For Copper Cable To FlatHigh copper alloy BARTAP
for joining a range of cable to bar or pad. One-wrench
installation.
CATALOG NUMBERQGFL1CB1 QGFL1CB1T6 QGFL26B1 QGFL26B1T6 QGFL26B2*
QGFL26B2T6* QGFL29B1* QGFL29B1T6* QGFL31B1* QGFL31B1T6* QGFL34B1
QGFL34B1T6 QGFL39B1 QGFL39B1T6 QGFL44B1 QGFL44B1T6 QGFL46B1
QGFL46B1T6 QGFL48B1
COPPER CONDUCTOR10 Sol. - 1 Str.
B1-1/8 1-1/4 1-1/2
H1-7/8 2-3/8 2-1/8 2-5/8 2-1/2 2-1/8 2-5/8 3-1/8 2-7/8 3-1/4
3-1/8 3-5/8 3-1/4 3-5/8 3-3/8 4-1/8 4 4-1/2 5-1/4
J3/8
T (MAX.)1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4 1/4 3/4
1/4 3/4 1/4 3/4 1/4
W1
8 Sol. - 2/0 Str.
1-1/8
6 Str. - 250 kcmil 1-5/8 2 Sol. - 350 kcmil 1-3/4 1/0 Sol. - 500
kcmil 2 350 - 750 kcmil 750 - 1000 kcmil 2-1/4 1000 - 1500 kcmil
1500 - 2000 kcmil
1-3/8 1-5/8
1/2
1-3/4
2-1/8 2-1/2 3
* Can be installed side by side or in-line on NEMA drilled
bar.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-34
Mechanical
BURNDY Products
TYPE FCBTRANSFORMER TAP ADAPTER For Copper and AluminumSilver
brazed 101% conductivity copper transformer tap adapter designed to
accommodate from 1 to 6 NEMA drilled copper or aluminum terminal
taps from a single secondary transformer outlet. Tin-plated. Order
mounting hardware & tap terminals separately.
Fig. 1
FIG. NO.1 2 1 2 1 Not Shown
CATALOG NUMBERFCB63-4N FCB63-6N FCB64-4N FCB64-6N FCB65-4N
FCB63-2NP300 FCB64-44NP50
A DIA..50 .50 .75 .75 1.00 .50 .75
H REF.5.25 5.25 5.75 5.75 7.00 5.00 9.00
L3.75 5.50 4.00 5.75 4.25 3.50 5.00
P2.25 2.25 2.75 2.75 4.00 3.00 5.00
NOTE: All pads are NEMA drilled.
Fig. 2
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-35
TYPE KPU-ACPOLYTAP Insulated Gutter Tap for All Copper and
Aluminum CombinationsWide range-taking tin-plated aluminum parallel
clamp and insulating cover assembly for industrial and multiple
story structure applications. Only six connectors cover the entire
14 Sol.-750 kcmil range. Covers having flexible fingers that
conform to conductor, fully insulating the connection. UL486B
listed for 600 volts maximum 90 C service. Cover and connector are
packaged together. No taping required. 600 Volt Max. 90 C
CATALOG NUMBERKPU29A26AC KPU29A29AC KPU34A26AC KPU34A34AC
KPU39A26AC KPU39A39AC
CONDUCTOR COPPER OR ALUMINUM RUN TAP1/0 Str. - 250 kcmil 1/0
Str. - 250 kcmil 4/0 Str. - 500 kcmil 4/0 Str. - 500 kcmil 500 -
750 kcmil 500 - 750 kcmil 14 Sol. - 2/0 Str. 6 Str. - 250 kcmil 14
Sol. - 2/0 Str. 6 Str. - 500 kcmil 14 Sol. - 2/0 Str. 1/0 Str. -
750 kcmil
W3-1/8 3-1/2 3-1/2
H3-3/8 3-1/2 3-7/8
L4-1/4 4-5/8 5-1/16
RECOMMENDED TIGHTENING TORQUE in-lb375 450 600
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
combinations. See note page A-2.
TYPE UCU-ACRISER TAPParallel-groove riser tap and insulation
cover for copper and aluminum. Wide range-taking assembly for
apartment house and light industrial applications. Cover and
connector are packaged together. Covers having insulating fingers
that conform to conductors, fully insulating the connection. UL486B
Listed for 600 volts max. 90 C service.
600 VOLT MAX. 90 C MAX.
CATALOG NUMBERUCU28AC
CONDUCTOR RUN TAP2 Str. - 4/0 Str. 10 Sol. - 2 Str.
W2-1/4
H1-13/16
L2-5/8
RECOMMENDED TIGHTENING TORQUE in-lb120
Listed torque values are for maximum conductor combinations
accommodated. Consult UL486 Tables 7-4, 7-5, 7-6 for smaller
combinations.
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-36
Mechanical
BURNDY Products
TYPE BIPCUL Listed 90 C, *600 VoltThe TYPE BIPC, Burndy
Insulation Piercing Connector is ideally suited for splicing and
tapping aluminum and copper conductor wire sizes: #10 AWG to 500
kcmil. The BIPC's unique insulation piercing design allows for use
on hot-line applications, eliminating the need for taping.
Features and Benefits Insulation piercing capability. Eliminates
the need for conductor insulation stripping. UL486B listed, AL9CU
rated. For copper and aluminum conductor combinations up to 90 *600
Volt applications. Insulation piercing design. For use on hot-line
applications. Eliminates the need for taping. Easy snap-out tabs.
Eases installation, protects connection from dirt and debris.
Simple bolt-on connection. Eases installation.
Fig. 1
Fig. 2MAX. VOLTAGE RATING600V 300V 300V 300V 300V 600V
CATALOG NUMBERBIPC1/0-2 BIPC4/0-6 BIPC4/0-1/0 BIPC350-4/0
BIPC350-350 BIPC500-4/0
CONDUCTOR RANGE RUN TAP1/0 - 8 AWG [50 - 6 mm2] 4/0 - 1/0 AWG
[95 - 50 mm2] 4/0 - 1/0 AWG [95 - 50 mm2] 350 - 4/0 AWG [185 - 95
mm2] 350 - 4/0 AWG [185 - 95 mm2] 500 - 350 kcmil [240 - 185 mm2] 2
- 8 AWG [35 - 6 mm2] 1/0 - 6 AWG [50 - 16 mm2] 4/0 - 1/0 AWG [95 -
50 mm2] 4/0 - 10 AWG [95 - 6 mm2] 350 - 4/0 AWG [185 - 95 mm2] 4/0
- 4 AWG [95 - 25 mm2]
BOLT SIZE5/16-18 5/16-18 5/16-18 3/8-16 3/8-16 3/8-16
SOCKET SIZE1/2 1/2 1/2 9/16 9/16 9/16
FIG. NO.1 2 2 1 2 1
DIMENSIONS H L W2.00 [51] 2.50 [64] 2.50 [64] 3.00 [76] 3.00
[76] 3.25 [83] 1.53 [39] 2.12 [54] 2.12 [2.12] 1.59 [40] 2.62 [67]
1.59 [40] 2.56 [65] 2.00 [51] 2.06 [52] 2.50 [64] 2.75 [70] 2.62
[67]
RECOMMENDED TORQUE (N,m)180 in. lbs. [20.3 N.m] 250 in. lbs.
[28.3 N.m] 250 in. lbs. [28.3 N.m] 375 in. lbs. [42.4 N.m] 300 in.
lbs. [33.9 N.m] 400 in. lbs. [45.2 N.m]
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-37
SPEC-BLOK POWER DISTRIBUTION CONNECTORSUnique, modular,
made-to-order, powerdistribution assemblies accommodate any number
of supply and load conductors in any number of poles. Capacity
matches the conductors accommodated and SPEC-BLOK assures uniform
loading. Adjacent poles are separated by easy-tohandle, wrap-around
insulating covers which eliminate taping and reduce heat build-up
by allowing air to flow freely around connectors. SPEC-BLOK is UL
Listed for copper or aluminum conductors for 600 volts. (AL9CU)
Assemblies are mounted on platforms suitable for easy installation
in wireway or junction box.
Features and Benefits Accommodate unlimited conductors. Fits
wide range of applications. Eliminates need for non-UL-listed
improvisation. Connector elements tin-plated. Provides high
reliability, low-resistance connections. User friendly,
space-saving design. Easy to install. Saves labor. 94-VO rated
insulation folds into place insulating the components. Saves time
and material. Allows easy installation. Connector caps removable
for easy cable lay-in. Saves labor. Makes installation easier.
Allows installation or straight-through conductors. Eases retrofit.
Belleville washers built-in on pressure screw assemblies, except in
assemblies installed with a 5/32 Allen wrench. Provides
high-integrity connections. Conductors can be cut or fed straight
through. Straight through installation ideal for riser
applications.
Contact BURNDY or Technical Services: 1-800-451-4956, or BURNDY
Customer Service: 1-800-346-4175
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-38
Mechanical
BURNDY Products
SPEC-BLOK
Features and Benefits The SPEC-BLOK system includes 12 connector
elements A wide variety of conductor sizes can be accommodated Each
element can be bolted together in parallel Provides an efficient
flow of current from one element to another AL9CU rated for Copper
or Aluminum conductors Dual-rated system, with UL486Bs highest
temperature rating 2 Wire (series), 4 (parallel), and Multi-Tap
versions available Nearly any conductor combination can be
terminated Tin-plated Aluminum Alloy Construction High-strength,
corrosion-resistant connector elements All SPEC-BLOKs are custom
made for nearly any Power Distribution system requirement Time
savings pre-assembled in our factory for immediate installation! D
T
E
W
SPEC-BLOK CONNECTORS
C
S
B
R
A
Q
U
P
Catalog Designation (Maximum Conductor)
Number of Conductors Accommodated
AL or CU Wire Range Under Each Cap
Dimensions
4 Conductor A
2 Conductor Q
4 Conductor
2 Conductor
Second Conductor Length Without Insulator ( if Height On First
required) Max 2 4 Conductors May Be Conductors Width Conductor
Conductor MUST Be 1/0-2/0 #12-2/02-9/16 1-1/2 2-1./8 7/8
Allen Wrench Size5/32
( 2/0) B ( 250) C ( 350) D ( 500) E ( 750) W 600-750
3/0-7504-7/8 2-1/4 7-1/4 2-5/8
R
3/0-250
#6-2503-1/8 1-11/16 4-1/4 1-3/8 1/4 3-5/16 1-13/16 4-5/8
1-1/2
S
1 to 4 ( 0, 1 or 2 per cap)
1 or 2 per cap
250-350
#6-350
T
400-500
#6-5004-1/16 2 5-5/8 1-3/4 3/8
Catalog Designation Number of Conductors (Maximum Conductor)
Accommodated 1 to 8 (0, 1 or 2 under P (1/0) each screw) U (1/0
& 500) 2 to 9 (0, 1 or 2 under each screw plus one large
conductor)
Large Groove __
Small Grooves** 6-1/0
Height On Maximum Conductors 3-1/2
Width 2
Length Without Insulator
Allen Wrench Size
1-3/4 3/0-500 6-1/0 4-1/8 2
5/32
** This range may be expanded to include #8 provided two
conductors are being installed in that particular element.
Canada: 1-800-387-6487
www.burndy.com
US: 1-800-346-4175
BURNDY Products
Mechanical
A-39
SPEC-BLOKMOUNTING PLATFORMSSPEC-BLOK Mounting Platforms are
rigid steel construction with a black finish. They can be supplied
for junction box mounting or wireway construction allowing trough
conductors to pass underneath the assemblies.
(CPB-)
(CPT-)L (Nominal)6 8 10 12 16-5/8 21-1/4
CATALOG NUMBERCPB6 CPB8 CPB10 CPB12 CPB16-5/8 CPB21-1/4
L (Overall)7-3/4 9-3/4 11-3/4 13-3/4 18-3/8 23
W (Overall)2-1/2 2-1/2 2-1/2 3-1/2 3-1/2 3-1/2
CATALOG NUMBERCPT6 CPT8 CPT10 CPT12 CPT16
L5-7/8 7-7/8 9-7/8 11-7/8 15-7/8
W2-1/2 3-1/2 3-1/2 3-1/2 3-1/2
H2-1/4 3 3-1/2 4 4
SPEC-BLOK catalog numbers describe exactly how the distribution
block is assembled:5DR-NDST-GQP-12 (assembly pictured) 5 DR Total
number of poles in the completed assembly One D unit and one R
unit, bolted in parallel, forming each phase pole (3 phase
poles)
N
Denotes the beginning of the neutral pole (where required) DST
One D unit, one S unit, and on T unit, bolted in parallel, forming
the neutral pole G QP Denotes the beginning of the ground pole
description (where required) One Q unit and on P unit, bolted in
parallel, forming the ground pole. Size (inches) of the wireway or
trough that is needed to enclose the assembly. If a junction box
enclosure is used, no number is used to denote the size of the
enclosure.
12
SPEC-BLOK IS A SYSTEM THAT CAN SOLVE MOST POWER DISTRIBUTION
APPLICATIONS!Throughout the catalog you will notice blue
highlighted items. These are the most frequently ordered BURNDY
Products. US: 1-800-346-4175 www.burndy.com Canada:
1-800-387-6487
A-40
Mechanical
BURNDY Products
QUESTIONNAIREFOR SPEC-BLOK OR ELECTRO-RAIL APPLICATIONSWhat is
the total capacity of the system?_____________amps How many poles
in the system (3-wire, 4-wire, single phase,
etc.)?_____________poles Are neutral conductors (when required)
different sizes (AWG/kcmil) than the phase conductors? _________the
same size __________different size Yes No Are any conductors
continuous? Yes No
If yes, which ones?____________________________________
___________________________________________________ What kind of
enclosure is connection assembly being mounted into and what are
inside space dimensions? Trough size
_________________________________________ Box, panel, cabinet,
other size___________________________ When is a quotation required?
Date:______________________ When is the material required?
Date:_____________________ CONDUCTOR TYPE (Cu/Al) Is there a
preference for a particular BURNDY distributor? Yes No If yes, give
name, location & telephone Number:
Name:______________________________________________
Is a ground connection required?
What are the quantities, sizes (AWG/kcmil) and material (Al/Cu)
of the incoming line conductors and outgoing load conductors?
QUANTITY LINE PER PHASE LOAD
SIZE
Address:____________________________________________ LINE PER
NEUTRAL LOAD LINE PER GROUND LOAD
__________________________________________________ Phone
#:____________________________________________
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-41
VERSI-POLEPOWER DISTRIBUTION BLOCKSVERSI-POLE Power Distribution
Blocks are designed to provide modular solutions to power
distribution applications. Each connector element is made from a
high conductivity aluminum alloy which is insulated with a high
strength polymer housing. One, two, and three pole versions
available. Add a pole (snap-together) blocks are also available for
wire sizes up to 500 kcmil. For use with Cu or Al. 600 V, AL9CU
rated.
Features and Benefits Add a pole feature available. Provides
capability to create as many poles as required. Up to 30 tap
conductors accommodated. Ideal for current distribution to multiple
locations. Single or dual run connections. Allows user to minimize
the number of connectors needed to do the job. Suitable for use
with aluminum or copper conductors. Provides maximum versatility.
600 V, AL9CU rated.* Meets or exceeds industry standard
requirements. Dead-front covers available Provides user protection
one cover per pole.* BDB-430-500-1 not UL recognized or CSA
certified
VERSI-POLE SNAPTOGETHER BLOCKSCATALOG NUMBERBDA-112-350
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CUAWG 6 - 350 kcmil
TAP WIRE RANGE AL9CUAWG 14 - 4
AMPERE RATING PER POLE350
NUMBER OF POLESADDER
BDA-16-350
AWG 6 - 350 kcmil
AWG 14 - 2/0
350
ADDER
BDA-16-500
AWG 4 - 500 kcmil
AWG 4 - 2/0
430
ADDER
BDA-26-350
AWG 6 - 350 kcmil
AWG 14 - 2/0
700
ADDER
BDA-212-500
AWG 4 - 500 kcmil
AWG 14 - 4
860
ADDER
BDA-26-500
AWG 4 - 500 kcmil
AWG 14 - 2/0
860
ADDER
BDA-24-500
AWG 4 - 500 kcmil
AWG 6 - 4/0
860
ADDER
BDA-11-500
AWG 4 - 500 kcmil AWG 4 - 500 kcmil
430
ADDER
BDA-22-350
AWG 6 - 350 kcmil AWG 6 - 350 kcmil
700
ADDER
BDA-22-500NOTES: 1. Order Optional BDB COVER1 per pole if
desired. 2. Snap-together blocks can also be assembled to 1, 2, 3
pole blocks to create multi-pole distribution blocks.
AWG 4 - 500 kcmil AWG 4 - 500 kcmil
860
ADDER
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products.
www.burndy.com Canada: 1-800-387-6487
US: 1-800-346-4175
A-42
Mechanical
BURNDY Products
VERSI-POLEVERSI-POLE 1, 2, 3 POLE DISTRIBUTION BLOCKS
CATALOG NUMBERBDB-16-2/0-1 BDB-16-2/0-2 BDB-16-2/0-3
BDB-26-2/0-1 BDB-26-2/0-2 BDB-26-2/0-3 BDB-112-350-1 BDB-112-350-2
BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3 BDB-14-500-1
BDB-14-500-2 BDB-14-500-3 BDB-16-500-1 BDB-16-500-2 BDB-16-500-3
BDB-162-500-1 BDB-162-500-2 BDB-162-500-3 BDB-26-350-1 BDB-26-350-2
BDB-26-350-3 BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-26-500-1
BDB-26-500-2 BDB-26-500-3 BDB-24-500-1 BDB-24-500-2
BDB-24-500-3
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CUAWG 12 - 2/0
TAP WIRE RANGE AL9CUAWG 14 - 4
AMPERE RATING PER POLE195
NUMBER OF POLES1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1
2 3 1 2 3 1 2 3
OPTIONAL COVER ORDER 1 PER POLEBDBCOVER2
AWG 14 - 2/0
AWG 14 - 2
390
BDBCOVER2
AWG 6 - 350 kcmil
AWG 14 - 4
350
BDBCOVER1
AWG 6 - 350 kcmil
AWG 14 - 2/0
350
BDBCOVER1
AWG 4 - 500 kcmil
AWG 14 - 2/0
430
BDBCOVER2
AWG 4 - 500 kcmil
AWG 14 - 2/0
430
BDBCOVER1
AWG 4 - 500 kcmil
AWG 14 - 2
430
BDBCOVER2
AWG 6 - 350 kcmil
AWG 14 - 2/0
700
BDBCOVER1
AWG 4 - 500 kcmil
AWG 14 - 4
860
BDBCOVER1
AWG 4 - 500 kcmil
AWG 14 - 2/0
860
BDBCOVER1
AWG 4 - 500 kcmil
AWG 6 - 4/0
860
BDBCOVER1
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-43
VERSI-POLEVERSI-POLE 1, 2, 3 SPLICE/REDUCER BLOCKSCATALOG
NUMBERBDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1
BDB-11-350-2 BDB-11-350-3 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3
BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-22-350-1 BDB-22-350-2
BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CUAWG 14 - 2/0
TAP WIRE RANGE AL9CUAWG 14 - 2/0
AMPERE RATING PER POLE195
NUMBER OF POLES1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3
OPTIONAL COVER ORDER 1 PER POLEBDBCOVER2
AWG 6 - 350 kcmil
AWG 6 - 350 kcmil
350
BDBCOVER2
AWG 6 - 500 kcmil
AWG 6 - 500 kcmil
430
BDBCOVER1
AWG 14 - 2/0
AWG 14 - 2/0
390
BDBCOVER2
AWG 6 - 350 kcmil
AWG 6 - 350 kcmil
700
BDBCOVER1
AWG 4 - 500 kcmil
AWG 4 - 500 kcmil
860
BDBCOVER1
SNAP TOGETHER SPLICE/REDUCER BLOCKSCATALOG
NUMBERBDC-14-2/0-1
CONNECTOR RUN TAP
RUN WIRE RANGE AL9CUAWG 14 - 2/0
TAP WIRE RANGE AL9CUAWG 14 - 4
AMPERE RATING PER POLE195
NUMBER OF POLES1
OPTIONAL COVER ORDER 1 PER POLEBDBCOVER3
BDA-14-2/0-1
AWG 14 - 2/0
AWG 14 - 4
195
ADDER
BDBCOVER3
BDC-11-2/0-1
AWG 14 - 2/0
AWG 14 - 2/0
195
1
BDBCOVER3
BDA-11-2/0-1
AWG 14 - 2/0
AWG 14 - 2/0
195
ADDER
BDBCOVER3
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-44
Mechanical
BURNDY Products
VERSI-POLE(Continued) VERSI-POLE 1, 2, 3 SPLICE/REDUCER
BLOCKSThese tables and illustrations refer to VERSIPOLE Power
Distribution Blocks listed on pages A-48 through A-50.
THE FIGURE TO THE LOWER RIGHT IS APPLICABLE TO THE
FOLLOWING:Catalog Number BDA-11-500 BDA-112-350 BDA-16-350
BDA-16-500 BDA-212-500 BDA-22-350 BDA-22-500 BDA-24-500 BDA-26-350
BDA-26-500 BDB-11-500-1 BDB-11-500-2 BDB-11-500-3 BDB-112-350-1
BDB-112-350-2 BDB-112-350-3 BDB-16-350-1 BDB-16-350-2 BDB-16-350-3
BDB-16-500-1 BDB-16-500-2 Number of Poles 1 (adder) 1 (adder) 1
(adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder) 1 (adder)
1 (adder) 1 2 3 1 2 3 1 2 3 1 2 Catalog Number BDB-16-500-3
BDB-212-500-1 BDB-212-500-2 BDB-212-500-3 BDB-22-350-1 BDB-22-350-2
BDB-22-350-3 BDB-22-500-1 BDB-22-500-2 BDB-22-500-3 BDB-24-500-1
BDB-24-500-2 BDB-24-500-3 BDB-26-350-1 BDB-26-350-2 BDB-26-350-3
BDB-26-500-1 BDB-26-500-2 BDB-26-500-3 BDB-430-500-1 Number of
Poles 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES2.50 2.81 5.31 7.81 (2.50 X N) + .31
Example for 10 poles: A = (2.50 X 10) + .31 = 25
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-45
VERSI-POLE(Continued) VERSI-POLE 1, 2, 3 SPLICE/REDUCER
BLOCKSThese tables and illustrations refer to VERSIPOLE Power
Distribution Blocks listed on pages A-41 through A-55. THE FIGURE
TO THE RIGHT IS APPLICABLE TO THE FOLLOWING:Catalog Number
BDB-11-2/0-1 BDB-11-2/0-2 BDB-11-2/0-3 BDB-11-350-1 BDB-11-350-2
BDB-11-350-3 BDB-14-500-1 BDB-14-500-2 BDB-14-500-3 BDB-16-2/0-1
BDB-16-2/0-2 BDB-16-2/0-3 BDB-162-500-1 BDB-162-500-2 BDB-162-500-3
BDB-22-2/0-1 BDB-22-2/0-2 BDB-22-2/0-3 BDB-26-2/0-1 BDB-26-2/0-2
BDB-26-2/0-3 Number of Poles 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1
2 3
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES1.64 1.94 3.57 5.20 (1.64 X N) + .30
Example for 10 poles: A = (1.64 X 10) + .30 = 16.20
APPLICABLE VERSI-POLETM ITEMS Catalog Number BDA-14-2/0-1
BDC-14-2/0-1 BDA-11-2/0-1 BDC-11-2/0-1 Number of Poles 1 (adder) 1
1 (adder) 1
NO. OF POLESAdder 1 2 3 N
DIMENSIONS A INCHES.81 1.08 1.89 2.70 (.81 X N) + .27
Example for 10 poles: A = (.81 X 10) + .27 = 8.37
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-46
Mechanical
BURNDY Products
BURNDY UNITAPCLEAR INSULATED MULTIPLE TAP CONNECTORSTap
connections and in-line splice/reduc tions are made quickly and
easily with the UNITAP line of connectors. UL486B Listed.
Dual-rated AL9CU for any stranded copper or stranded aluminum
applications. 600 Volt, 90 C.
Features and Benefits Clear Plastisol covered AL6061-T6 aluminum
body. Saves time, lowers installation costs, eliminates taping.
Clear Plastisol. Allows visual confirmation that conductor is
properly inserted. Oxide inhibitor pre-installed. Inhibits moisture
and contaminants from entering the contact area. Range-taking.
Reduces number of connectors carried in inventory.
2 PORT 1 or 2 Sided EntryCatalog NumberBIT4 BITO4 BIT2/0 BITO2/0
BIT250 BITO250 BIT350 BITO350 BIT600 BITO600 BIT750* BITO750** Not
UL Listed
# of Ports2 2 2 2 2 2 2 2 2 2 2 2
Wire Range (AWG/kcmil)#14 - #4 #14 - #4 #14 - 2/0 #14 - 2/0 #10
- 250 #10 - 250 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #2 - 750 #2 -
750
L1.16 1.16 1.52 1.52 2.03 2.03 2.22 2.22 2.72 2.72 2.87 2.87
W1.16 1.50 1.40 1.56 2.07 2.64 2.32 3.00 2.38 3.00 2.70 3.38
H1.25 1.25 1.38 1.38 2.13 2.13 2.50 2.50 2.75 2.75 3.00 3.00
Hex Key1/8 1/8 3/16 3/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8
Fig. No.1 2 1 2 1 2 1 2 1 2 1 2
Fig. 1
Fig. 2
IN-LINE SPLICER/REDUCERCatalog NumberBISR2 BISR1/0 BISR250
BISR350 BISR500
Wire Range (AWG/kcmil)#14 - 2 #14 - 1/0 #10 - 250 #10 - 350 #6 -
500
L2.38 2.91 4.01 4.63 5.00
W0.75 0.91 1.19 1.34 1.62
H1.22 1.38 2.10 2.35 2.62
Hex Key5/32 3/16 5/16 5/16 3/8
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. Canada:
1-800-387-6487 www.burndy.com US: 1-800-346-4175
BURNDY Products
Mechanical
A-47
BURNDY UNITAP
MULTI-PORT Single-Sided EntryCatalog NumberBIBS4-3 BIBS4-4
BIBS4-5 BIBS4-6 BIBS4-8 BIBS2/0-3 BIBS2/0-4 BIBS2/0-5 BIBS2/0-6
BIBS2/0-8 BIBS2/0-10 BIBS2/0-12 BIBS2/0-14 BIBS250-3 BIBS250-4
BIBS250-5 BIBS250-6 BIBS250-8 BIBS250-10 BIBS250-12 BIBS250-14
BIBS350-3
# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 3 4 5 6 8 10 12 14 3
4 5 6 8 10 12 14 3 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 - 4 #14 -
2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14
- 2/0 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250
#10 - 250 #10 - 250 #10 - 350
L1.59 2.03 2.47 2.91 3.78 2.19 2.86 3.53 4.20 5.55 6.89 8.24
9.58 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29 3.13
W1.25 1.25 1.25 1.25 1.25 1.31 1.31 1.31 1.31 1.31 1.31 1.31
1.31 2.07 2.07 2.07 2..07 2.07 2.07 2.07 2.07 2.32
H1.25 1.25 1.25 1.25 1.25 1.38 1.38 1.38 1.38 1.38 1.38 1.38
1.38 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.50
Hex Key1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16 3/16
3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16
Catalog NumberBIBS350-4 BIBS350-5 BIBS350-6 BIBS350-8 BIBS350-10
BIBS350-12 BIBS350-14 BIBS600-3 BIBS600-4 BIBS600-5 BIBS600-6
BIBS600-8 BIBS600-10 BIBS600-12 BIBS600-14 BIBS750-3* BIBS750-4*
BIBS750-6* BIBS750-8* BIBS750-10* BIBS750-12* BIBS750-14** Not UL
Listed
# of Wire Range Ports (AWG/kcmil)4 5 6 8 10 12 14 3 4 5 6 8 10
12 14 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350 #10
- 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 -
600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 - 750 #2 - 750 #2 - 750
#2 - 750 #2 - 750 #2 - 750
L4.04 4.95 5.86 7.68 9.50 11.32 13.14 4.00 5.28 6.56 7.84 10.41
12.97 15.53 18.09 4.25 5.63 8.37 11.13 13.87 16.63 19.37
W2.32 2.32 2.32 2.32 2.32 2.32 2.32 2.38 2.38 2.38 2.38 2.38
2.38 2.38 2.38 2.70 2.70 2.70 2.70 2.70 2.70 2.70
H2.50 2.50 2.50 2.50 2.50 2.50 2.50 2.75 2.75 2.75 2.75 2.75
2.75 2.75 2.75 3.00 3.00 3.00 3.00 3.00 3.00 3.00
Hex Key5/16 5/16 5/16 5/16 5/16 5/16 5/16 3/8 3/8 3/8 3/8 3/8
3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8 3/8
Throughout the catalog you will notice blue highlighted items.
These are the most frequently ordered BURNDY Products. US:
1-800-346-4175 www.burndy.com Canada: 1-800-387-6487
A-48
Mechanical
BURNDY Products
BURNDY UNITAP
MULTI-PORT Double-Sided EntryCatalog NumberBIBD4-2 BIBD4-3
BIBD4-4 BIBD4-5 BIBD4-6 BIBD4-8 BIBD2/0-2 BIBD2/0-3 BIBD2/0-4
BIBD2/0-5 BIBD2/0-6 BIBD2/0-8 BIBD2/0-10 BIBD2/0-12 BIBD2/0-14
BIBD250-2 BIBD250-3 BIBD250-4 BIBD250-5 BIBD250-6 BIBD250-8
BIBD250-10 BIBD250-12 BIBD250-14 BIBD350-2
# of Wire Range Ports (AWG/kcmil)2 3 4 5 6 8 2 3 4 5 6 8 10 12
14 2 3 4 5 6 8 10 12 14 2 #14 - #4 #14 - #4 #14 - #4 #14 - #4 #14 -
#4 #14 - #4 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #14 -
2/0 #14 - 2/0 #14 - 2/0 #14 - 2/0 #10 - 250 #10 - 250 #10 - 250 #10
- 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 - 250 #10 -
350
L1.16 1.59 2.03 2.47 2.91 3.78 1.52 2.19 2.86 3.53 4.20 5.55
6.89 8.24 9.58 2.03 2.97 3.91 4.84 5.78 7.66 9.53 11.41 13.29
2.22
W1.50 1.50 1.50 1.50 1.50 1.50 1.56 1.56 1.56 1.56 1.56 1.56
1.56 1.56 1.56 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64
3.00
H1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.25
1.25 1.25 1.25 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13 2.13
2.50
Hex Key1/8 1/8 1/8 1/8 1/8 1/8 3/16 3/16 3/16 3/16 3/16 3/16
3/16 3/16 3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16
5/16
Catalog NumberBIBD350-3 BIBD350-4 BIBD350-5 BIBD350-6 BIBD350-8
BIBD350-10 BIBD350-12 BIBD350-14 BIBD600-2 BIBD600-3 BIBD600-4
BIBD600-5 BIBD600-6 BIBD600-8 BIBD600-10 BIBD600-12 BIBD600-14
BIBD750-2* BIBD750-3* BIBD750-4* BIBD750-6* BIBD750-8* BIBD750-10*
BIBD750-12* BIBD750-14*
# of Wire Range Ports (AWG/kcmil)3 4 5 6 8 10 12 14 2 3 4 5 6 8
10 12 14 2 3 4 6 8 10 12 14 #10 - 350 #10 - 350 #10 - 350 #10 - 350
#10 - 350 #10 - 350 #10 - 350 #10 - 350 #4 - 600 #4 - 600 #4 - 600
#4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #4 - 600 #2 - 750 #2 -
750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750 #2 - 750
L3.13 4.04 4.95 5.86 7.68 9.50 11.32 13.14 2.56 3.77 4.97 6.17
7.37 9.78 12.97 15.53 18.09 2.87 4.25 5.63 8.37 11.13 13.87 16.63
19.37
W3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00 3.00
3.00 3.00 3.00 3.00 3.00 3.38 3.38 3.38 3.38 3.38 3.38 3.38
3.38
H2.50 2