2 Cochran Drive Ayr, Ontario, Canada N0B 1E0 Toll Free: 1-800-567-3557 Technical Support: Ext. 240 Fax: 1-519-624-6575 www.oillift.com 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components 2 SPEED VICTORY DOORS
41

2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

Jul 04, 2018

Download

Documents

hoangdieu
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

2 Cochran DriveAyr, Ontario, Canada

N0B 1E0

Toll Free: 1-800-567-3557Technical Support: Ext. 240

Fax: 1-519-624-6575

www.oillift.com

2 SPEED VICTORY DOORHOME ELEVATOR ENTRANCES

NON FIRE RATED

Number One In Fluitronic Elevator Components 2 SPEED VICTORY DOORS

Page 2: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

This document is for information purposes only. We reserve the right to modify the reported specifications, in any parts, without notice. The printed drawings are informational only, and there might be differences with the actual product.

2 SPEED VICTORY DOORS

Table of Contents● GENERAL DISCLOSURE ...................................................................................................1.00

● DIMENSIONAL DATA ..........................................................................................................2.00 2 SPEED DOOR OPERATOR WITH DOORS AND SILL ................................................2.01 2 SPEED LANDING ENTRANCE WITH DOORS AND SILL ...........................................2.02

● INTERFACE OF DOOR OPERATOR WITH WOOD CAB ..................................................3.00

● INTERFACE OF LANDING ENTRANCE WITH HOISTWAY ..............................................4.00

● INSTALLATION OF DOOR OPERATOR, CAB SILL AND CAB DOORS ............................5.00

● INSTALLATION OF LANDING ENTRANCE .......................................................................6.00

● CONSTRUCTION OF ENTRANCE AFTER ENTRANCES ARE SET .................................7.00

● ELECTRICAL DIAGRAMS OF THE CONTROLLER BOARD .............................................8.00

● SET UP OF THE CONTROL BOARD .................................................................................9.00

● TROUBLE SHOOTING .....................................................................................................10.00

Page 3: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

1.00

GENERAL DISCLOSUREThe purpose of this manual is to provide OLS customers with support documentation to aid in the Interface and installation of 2 Speed Victory Door system.

The topics covered in this manual include: - Dimensional Data of the Door Operator and Landing Entrance- Interface of Door Operator, Cab Doors and Cab sill with Cab- Interface of Landing Entrance with building/hoistway- Installation of Door Operator and Doors- Installation of Landing Entrance- Electrical Interface, Set-up, and Troubleshooting.

We strongly recommend that the interface of Doors to your Cab and Landing Entrance are prototyped in your own facility. Do not try to prototype in the field!

Please Note:Door Key and Programming tool have to be ordered separately Do not give door key to home owner and or any other person. Door Keys should be provided to Licensed Elevator Technicians only!

Any additional information and technical support please contact OLS at 1-800-567-3557.

2 SPEED VICTORY DOORS

Page 4: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

1

1

2

2

3

3

4

4

A A

B B

C C

D D

SHEET 1 OF 1

DRAWN

CHECKED

QA

MFG

APPROVED

fernandog 2/15/2008

DWG NO

DOOR OPERATOR

TITLE

SIZE

CSCALE

REVG

H

E

9 1/4235( ")D

DOOR RESTRICTOR

F

60(2 3/8")

100(4")

DOOR SILL

*DIMENSION FROM SILL LINE

2.01

2 SPEED DOOR OPERATOR

ALL DIMENSIONS SHOWN IN mm(in)CLEAR OPENING A B C D E F G H

900(35 1/2") X 2000(78 3/4") 2000(78 3/4") 2185(86") 2400(94 1/2") 625 (24 5/8") 1300(51 3/16") 1045(41 1/8") 960(37 3/4") 1350(53 1/8")

900(35 1/2") X 2100(82 5/8") 2100(82 5/8") 2285(90") 2600(102 3/8") 625 (24 5/8") 1300(51 3/16") 1045(41 1/8") 960(37 3/4") 1350(53 1/8")

900(35 1/2") X 2400(94 1/2") 2400(94 1/2") 2585(101 3/4") 2900(114 1/8") 625 (24 5/8") 1300(51 3/16") 1045(41 1/8") 960(37 3/4") 1350(53 1/8")

CLEAR OPENING900(35 1/2”)

2 SPEED VICTORY DOORS

Page 5: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

2.02

2 SPEED LANDING ENTRANCE

ALL DIMENSIONS SHOWN IN mm(in)CLEAR OPENING A B C D E F G H

900(35 1/2") x 2000(78 3/4") 2000(78 3/4") 900(35 1/2") 2225(87 5/8") 1135(44 11/16") 1375(54 1/8") 1140(44 7/8") 960(37 3/4") 1450(57 1/16")

900(35 1/2") x 2100(82 5/8") 2100(82 5/8") 900(35 1/2") 2325(91 1/2") 1135(44 11/16") 1375(54 1/8") 1140(44 7/8") 960(37 3/4") 1450(57 1/16")

900(35 1/2") x 2400(94 1/2") 2400(94 1/2") 900(35 1/2") 2625(103 5/16") 1135(44 11/16") 1375(54 1/8") 1140(44 7/8") 960(37 3/4") 1450(57 1/16")

CLEAR OPENING900(35 1/2”) x 2000(78 3/4”)900(35 1/2”) x 2100(82 5/8”)900(35 1/2”) x 2400(94 1/2”)

2 SPEED VICTORY DOORS

Page 6: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

INTERFACE OF OPERATOR WITH WOOD CAB

3.01

INTERFACE SHOWN WITH WOOD CAB. FOR STEEL CAB INTERFACE USE DIMENSIONS SHOWN ONLY

CLEAR OPENING A B C D E

900(35 1/2") X 2000(78 3/4") 461(18 1/8") 439(17 9/32") 900(35 1/2") 2000(78 3/4") 2185(86")

900(35 1/2") X 2100(82 5/8") 461(18 1/8") 439(17 9/32") 900(35 1/2") 2100(82 5/8") 2285(90")

900(35 1/2") X 2400(94 1/2") 461(18 1/8") 439(17 9/32") 900(35 1/2") 2400(94 1/2") 2585(101 3/4")

NOTE:D= CLEAR OPENING HEIGHT FROM UNDERSIDE OF HEADER TO FINISHED FLOOR (CAB SILL)E= TOP OF UNI-STRUT TO FINISHED FLOOR (CAB SILL)ALL DIMENSIONS SHOWN IN mm(in)

2 SPEED VICTORY DOORS

Page 7: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

4.00

INTERFACE OF LANDING ENTRANCE WITH HOISTWAY

ALL DIMENSIONS SHOWN IN mm(in)CLEAR OPENING FRAME HEIGHT (A) ROUGH OPENING (B) MINIMUM (C) FRAME WIDTH (D)

900(35 1/2") X 2000(78 3/4") 2225(87 5/8") 2276(89 5/8") 505(19 7/8") 1140(44 7/8")

900(35 1/2") X 2100(82 5/8") 2325(91 1/2") 2375(93 1/2") 505(19 7/8") 1140(44 7/8")

900(35 1/2") X 2400(94 1/2") 2625(103 5/16") 2675(105 5/16") 505(19 7/8") 1140(44 7/8")

2 SPEED VICTORY DOORS

Page 8: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

1

1

2

2

3

3

4

4

A A

B B

C C

D D

SHEET 1 OF 1

DRAWN

CHECKED

QA

MFG

APPROVED

fernandog 3/10/2008

DWG NO

BOX DRAWINGS

TITLE

SIZE

CSCALE

REV

1

1

2

2

3

3

4

4

A A

B B

C C

D D

SHEET 1 OF 1

DRAWN

CHECKED

QA

MFG

APPROVED

fernandog 3/10/2008

DWG NO

BOX DRAWINGS

TITLE

SIZE

CSCALE

REV

INSTALLATION OF DOOR OPERATOR, CAB SILL AND CAB DOORS

REQUIRED WORKERS

GUIDE LEGEND:

REQUIRED TOOLS

CAUTION/ATTENTION

THE COMPLETE DOOR OPERATOR IS PACKAGED IN TWO BOXES.

INCLUDED IN DOOR OPERATOR BOX: INCLUDED IN DOOR PANEL BOX:1 - DOOR OPERATOR 1 - SET OF DOORS1 - OPERATOR DOOR SILL2 - OPERATOR MOUNTING BRACKETS1 - CAB DOOR SILL1 - HARDWARE SET (SEE BELOW)

SET OF PANELS - 80lbsDOOR OPERATOR - 100lbs

5.00

2 SPEED VICTORY DOORS

Page 9: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

# DESCRIPTION QTY IMAGE

1 PLAIN WASHER OD=20 - M10 10

2 TOOTHED WASHER - M10 14

3 PLAIN WASHER OD=30 - M10 3

4 SPLIT LOCK WASHER - M10 3

5 CARRAGE BOLT - M10x25 3

6 HEX NUT - M10 3

7 FLAT HEAD SOCKET CAP SCREW - M10x30 2

8 TOOTHED CROWN WASHER - M10 2

9 CAGE NUT - M10 16

10 SOCKET HEAD CAP SCREW - M10x20 14

11 ECCENTRIC WASHER - M10 4

12 SHIMS - 1mm & 2mm THICK4

SETS

13BUTTON HEAD SOCKET CAP SCREW - M5x10

(FOR TOE GUARD)3

14SERRATED FLANGE HEX NUT - M5

(FOR TOE GUARD)3

15 GIB/GUIDE (WITH RUBBER) 4

NOTE: HARDWARE IS NOT PROVIDED TO

SECURE THE TWO OPERATOR MOUNTING

BRACKETS TO THE CAB UNI-STRUT.

5.01

INSTALLATION OF DOOR OPERATOR, CAB SILL AND CAB DOORS

CAUTION! DO NOT REMOVE PROTECTIVE FILM COATING FROM ANY OF THE ITEMS UNTIL ENTRANCE AND DOOR PANELS ARE FULLY INSTALLED AND CONSTRUCTION IS FINISHED.

THE FOLLOWING SET OF HARDWARE PROVIDED TO INSTALL THE OPERATOR AND DOORS. IF WOOD ANCHORS ARE REQUIRED THEY WILL NEED TO BE ORDERED SEPARATELY.

2 SPEED VICTORY DOORS

Page 10: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

5.02

INSTALLATION OF DOOR OPERATOR

STEP 1: INSTALL THE MOUNTING BRACKETS AS SHOWN. DO NOT TIGHTEN.

ONE WORKER REQUIRED

6mm ALLEN KEY TO INSTALL SCREWS

2 SPEED VICTORY DOORS

Page 11: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

INSTALLATION OF DOOR OPERATOR

UNI-STRUTS

5.03

TWO WORKERS REQUIRED

TOOLS AND HARDWARE OF CUSTOMER’S CHOICE (HARDWARE IS NOT PROVIDED TO SECURE MOUNTING BRACKETS TO UNI-STRUT)

CAUTION: OPERATOR IS HEAVY; 100 LBS.

STEP 2: ATTACH THE DOOR OPERATOR TO CAB, THEN SECURE MOUNTING BRACKETS TO UNI-STRUTS.

2 SPEED VICTORY DOORS

Page 12: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

INSTALLATION OF DOOR OPERATOR

TWO WORKERS REQUIRED

TOOLS AND HARDWARE OF CUSTOMER’S CHOICE

ENSURE OPERATOR DOOR TRACK IS PARALLEL TO SILL! DO NOTSTEP ON OPERATOR ONCE POSITIONED AND LEVELED.

STEP 3: SET DOOR TRACK HEIGHT PARALLEL TO CAB SILL. SEE TABLE BELOW.

5.04

2 SPEED VICTORY DOORS

CLEAR OPENING TRACK HEIGHT(H)

900(35 1/2") X 2000(78 3/4") 2065(81 15/16”)

900(35 1/2”) X 2100(82 5/8”) 2165(85 1/4")

900(35 1/2”) X 2400(94 1/2”) 2465(97")

Page 13: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

SILL

TRANSITION PIECE

TRANSITIONSILL

5.05

INSTALLATION OF CAB SILL

ONE WORKER REQUIRED

10mm WRENCH

STEP 4: PLACE TRANSITION PIECE ONTO SILL AND SLIDE INTO PLACE. THEN SECURE SILL USING HARDWARE SHOWN BELOW.

2 SPEED VICTORY DOORS

Page 14: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

5.06

INSTALLATION OF CAB PANELS(DOORS)

STEP 5: SNAP THREE FLOATING NUTS INTO OPERATOR HANGER. THEN ATTACH DOOR PANELS (SLOW SPEED DOOR FIRST). SECURE DOOR PANELS TO HANGERS WITH HARDWARE SHOWN BELOW.

ONE WORKER REQUIRED

10mm ALLEN KEY

ATTENTION: ENSURE DOORS ARE INSTALLED ALIGNED.

2 SPEED VICTORY DOORS

Page 15: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

INSTALLATION OF CAB PANELS(DOORS)

ONE WORKER REQUIRED

10mm ALLEN KEY

ATTENTION: ENSURE DOORS ARE 6(1/4”) ABOVE SILL.

STEP 6: SNAP TWO FLOATING NUTS INTO EACH DOOR GIB. SECURE DOOR GIBS TO BOTTOM OF DOOR PANEL USING HARDWARE SHOWN BELOW

5.07

2 SPEED VICTORY DOORS

Page 16: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

�������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������������

������

��

03

12

2.4 - DOOR PANEL ADJUSTMENT 1. Open both doors all the way. 2. Shift doors on hanger until they are flush with cab return. 3. Once in place, rotate eccentric washer with special tool (provided in operator package) until door is level, then

tighten bolts.

Figure 2.4.1

INSTALLATION OF CAB PANELS(DOORS)

ONE WORKER REQUIRED

10mm ALLEN KEY AND SPECIALTY TOOL

ATTENTION: ENSURE DOORS ARE 6(1/4”) ABOVE SILL. ONCE SET ENSURE THAT DOORS RUN FREELY BACK AND FORTH.

STEP 7: SET GAP BETWEEN BOTTOM OF DOOR PANELS AND SILL USING A 1/4” SHIM. ADD SHIM AT HANGER AS NECESSARY TO MAINTAIN A RUNNING CLEARANCE OF 5(3/16”) BETWEEN EACH PANEL. MAKE FINAL ADJUSTMENTS USING SPECIALTY TOOL TO ENSURE PANELS ARE TRUE TO STRIKE AND RETURN POST. TIGHTEN ALL DOOR HARDWARE WHEN COMPLETE.

SPECIALTY TOOL

5.08

2 SPEED VICTORY DOORS

Page 17: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.00

1

1

2

2

3

3

4

4

A A

B B

C C

D D

SHEET 1 OF 1

DRAWN

CHECKED

QA

MFG

APPROVED

fernandog 3/10/2008

DWG NO

BOX DRAWINGS

TITLE

SIZE

CSCALE

REV

1

1

2

2

3

3

4

4

A A

B B

C C

D D

SHEET 1 OF 1

DRAWN

CHECKED

QA

MFG

APPROVED

fernandog 3/10/2008

DWG NO

BOX DRAWINGS

TITLE

SIZE

CSCALE

REV

INCLUDED IN LANDING MECH BOX: INCLUDED IN DOOR PANEL BOX:1 - LANDING MECHANISM 1 - SET OF DOORS1 - STRIKE POST1 - RETURN POST1 - LANDING SILL1 - HARDWARE SET (SEE BELOW)3 - SILL SUPPORT BRACKETS

INSTALLATION OF LANDING ENTRANCE

THE COMPLETE LANDING ENTRANCE IS SUPPLIED IN TWO BOXES.

REQUIRED WORKERS

GUIDE LEGEND:

REQUIRED TOOLS

CAUTION/ATTENTION

SET OF PANELS - 80lbsLANDING MECHANISM - 100lbs

2 SPEED VICTORY DOORS

Page 18: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

CAUTION! DO NOT REMOVE PROTECTIVE FILM COATING FROM ANY OF THE ITEMS UNTIL ENTRANCE AND DOOR PANELS ARE FULLY INSTALLED AND CONSTRUCTION IS FINISHED.

THE FOLLOWING SET HARDWARE PROVIDED TO INSTALL THE LANDING MECHANISM AND DOORS. IF WOOD ANCHORS ARE REQUIRED THEY WILL NEED TO BE ORDERED SEPARATELY.

INSTALLATION OF LANDING ENTRANCE

PART No.

127024

NOTE:

COMPONENT SPECIFICATIONDESCRIPTION: FIRE RATED LANDING FRAME (CONCRETE)

CHARACTERISTICS: 915x2150 - 2 SPEED, RH, BEIGE FIRE RATED LANDING FRAME W/ MECHANISM

SPECIFIED BY:

F.G.

DATE:

MAY 1/08

PAGE No.

1 OF 2

1. HAND - NORTH AMERICAN R/H EUROPEAN L/H

2. FINISH - POLIMOD BEIGE 85 (POWDER COAT)

3. CSA APPROVED INTERLOCK

4. FITTED WITH NORTH AMERICAN DOOR RESTRICTOR CAM

5. 2 LANDING MECHANISM BRACKETS (SEE FIG. 1)

6. TOE GUARD 940x150mm

7. LANDING SILL SUPPORT 1015mm LONG

8. LANDING SILL 1473mm LONG WITH 915mm TRANSITION PIECE

9. LANDING DOOR LOCK CONTACT COVER

10. PROVIDE STANDARD HARDWARE (SEE HARDWARE LIST)

11. PACKAGE ALL HARDWARE AS FOLLOWS:

BAG A: 1,2,9,10,11,12,13

BAG B: 3,4,5,6,7,8,14,15,16

12. PACKAGE ALL ITEMS INCLUDING THE RETURN POST, STRIKE POST,

AND LANDING MECHANISM IN A CARDBOARD BOX (SEE PAGE 2)

13. AFFIX LABEL ON BOX SHOWING OLS PART NUMBER &

VICTORY DOOR PART NUMBER(S)

# DESCRIPTION QTY IMAGE

10 GIB/GUIDE (WITH RUBBER) 4

11 SHIMS - 1mm & 2mm THK4

SETS

12BUTTON HEAD SOCKET CAP SCREW - M5x10

(FOR TOE GUARD)3

13 SQUARE NUT - M5 (FOR TOE GUARD) 3

14 DOWEL (MASONARY ANCHOR) - M10x95 9

15 ALUMINIUM CLIP FOR WIRE 1

16 EXTENSION SPRING 465mm 1 N/A

# DESCRIPTION QTY IMAGE

1 PLAIN WASHER OD=20 - M10 10

2 TOOTHED LOCK WASHER - M10 14

3 PLAIN WASHER OD=30 - M10 5

4 SPLIT LOCK WASHER - M10 5

5 CARRIAGE BOLT - M10x25 5

6 HEX NUT - M10 5

7 CAGE NUT (STANDARD) - M10 14

8 SOCKET HEAD CAP SCREW - M10x20 14

9 ECCENTRIC WASHER - M10 4

FIG. 1

REVISION HISTORY

REV DESCRIPTION DATE APPROVED E.R.#

2 COMPLETE SPEC REVISION 05/01/08 F.G.

6.01

2 SPEED VICTORY DOORS

Page 19: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

SUPPORT BRACKETS

SILL

6.02

INSTALLATION OF LANDING ENTRANCE SILL SUPPORT ASSEMBLY (TYPE 1)

ONE WORKER REQUIRED

17mm WRENCH/ADJUSTABLE WRENCH

NOTE: DEPENDING WHEN YOU PURCHASED THE LANDING ENTRANCE, YOU MAY RECEIVE A TYPE 1 OR TYPE 2 SILL SUPPORT ASSEMBLY..

STEP 1: ASSEMBLE THE LANDING SILL, TRANSITION, LANDING SILL SUPPORT AND LANDING SILL SUPPORT BRACKETS AS SHOWN.

TRANSITION

2 SPEED VICTORY DOORS

Page 20: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

INSTALLATION OF LANDING ENTRANCE SILL SUPPORT ASSEMBLY (TYPE 2)

ONE WORKER REQUIRED

17mm WRENCH/ADJUSTABLE WRENCH

STEP 1: ASSEMBLE THE LANDING SILL, TRANSITION, LANDING SILL SUPPORT AND LANDING SILL SUPPORT BRACKET AS SHOWN.

SUPPORTBRACKET

SILL

TRANSITION

6.03

2 SPEED VICTORY DOORS

Page 21: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

TYPE 1

SILL

6.04

INSTALLATION OF LANDING ENTRANCEMOUNTING THE SILL SUPPORT BRACKETS

ONE WORKER REQUIRED

LANDING SILL ASSEMBLY (SHOWN FULLY ASSEMBLED)

17mm WRENCH/ADJUSTABLE WRENCH

ATTENTION: BEFORE PROCEEDING WITH INSTALLATION THERE MUST BE A RUNNING PLATFORM AND SILL(S) ON THE PLATFORM.

TYPE 2

SUPPORT BRACKETS

SUPPORT BRACKET

SILL

2 SPEED VICTORY DOORS

Page 22: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.05

INSTALLATION OF LANDING ENTRANCELOCATING THE LANDING SILL ASSEMBLY

TWO WORKERS REQUIRED

2 - 4FT LEVEL, MARKING TOOL, DRILL AND HAMMERCONCRETE: 3/8” MASONRY DRILLWOOD: 1/8” H.S.S. DRILL FOR PILOT HOLE

OPENING 900(35 1/2”) ‘X’: MIN 505(19 7/8”)

STEP 2: LOCATE LANDING SILL ASSEMBLY AS SHOWN AND SECURE. NOTE THAT THE CAB SILL IS 100(3 15/16”) SHORTER THEN LANDING SILL. ALIGN LANDING SILL SO THAT THE RETURN END OF THE SILL IS FLUSH WITH THE CAB SILL. THE TRANSITION PIECE CAN BE READJUSTED LATER ON.

RETURN END

2 SPEED VICTORY DOORS

Page 23: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

NOTE:OPENING 900(35 1/2”) ‘X’: MIN 1400(55”)

TOP OF FINISHED FLOOR

LANDING SILL

CAB SILL

SILL SUPPORT

30mm(1 3/16”)

NOTE: IF CONSTRUCTION IS MASONRY BLOCK, THE BLOCKS WILL NEED TO BE FILLED WITH CONCRETE

ATTENTION: RUNNING CLEARANCE BETWEEN CAB SILL AND LANDING MUST BE 30(1 3/16”)

NOTE: LANDING SILL MUST BE LEVEL AND ADJUSTED TO CAB SILL AT ALL LANDINGS.

MASONRY CONSTRUCTION1. MARK HOLES AS SHOWN.2. DRILL TWO HOLES 3/8”Ø X 3” DEEP WITHMASONRY DRILL.3. SECURE LANDING SILL ASSEMBLY WITHMASONRY ANCHORS (ITEM #14).4. USE REMAINING HOLES AS A TEMPLATETO ATTACH THE REST OF THE ANCHORS.

WOOD CONSTRUCTION1. MARK HOLES AS SHOWN.2. DRILL TWO HOLES 1/8”Ø X 3” DEEP WITHA H.S.S. DRILL.3. SECURE LANDING SILL ASSEMBLY WITHWOOD LAGS.4. USE REMAINING HOLES AS A TEMPLATETO ATTACH THE REST OF THE LAGS.

NOTE: WOOD LAGS ARE NOT PROVIDED FOR WOOD CONSTRUCTION INSTALLATION

NOTE: IN WOOD CONSTRUCTION TWO 2X10” WOOD SUPPORTS SHOULD BE PRESENT TO SECURE THE WOOD LAGS

6.06

2 SPEED VICTORY DOORS

Page 24: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.07

STRIKE POST SEE 6.08

RETURN POST SEE 6.08

LANDING MECHANISM

(CAB HEADER) SEE 6.10 AND

6.11

TWO WORKERS REQUIRED

6mm ALLEN KEY, 17MM WRENCH/ADJUSTABLE WRENCH, PLASTIC CLAMPS

INSTALLATION OF LANDING ENTRANCEASSEMBLY OF LANDING ENTRANCE

STEP 3: REMOVE THE SILL AND SUPPORT FROM THE ASSEMBLY LEAVING THE SUPPORT BRACKET(S) ATTACHED IN THE HOISTWAY WALL. PLACE THE LANDING ENTRANCE ITEMS ON WOODEN HORSES OR STANDS AND ASSEMBLE AS SHOWN BELOW.

SILL SUPPORTSEE 6.08 AND 6.09

2 SPEED VICTORY DOORS

Page 25: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.08

ONE WORKER REQUIRED

6mm ALLEN KEY

STEP 4: ATTACH THE STRIKE AND RETURN POSTS TO THE LANDING MECHANISM(HEADER) USING THE HARDWARE ALREADY ATTACHED TO THE POST BRACKETS.

RETURN POSTSTRIKE POST

INSTALLATION OF LANDING ENTRANCEASSEMBLY OF LANDING ENTRANCE

SCREW

CROWN WASHER

CAGE NUT

2 SPEED VICTORY DOORS

Page 26: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.09

SILL

TRANSITION

INSTALLATION OF LANDING ENTRANCE ASSEMBLY OF LANDING ENTRANCE

ONE WORKER REQUIRED

17mm WRENCH/ADJUSTABLE WRENCH

STEP 5: SLIDE AN EXTRA CARRIAGE BOLT THOUGH SILL. PLACE SILL ON TOP OF POST BRACKETS AND ENSURE THAT TRANSITION IS ATTACHED TO THE SILL. FASTEN THE TWO CARRIAGE BOLTS ATTACHING THE SILL TO THE POST BRACKETS, LEAVING ONE CARRIAGE BOLT HANDING IN THE MIDDLE.

EXTRA BOLT

2 SPEED VICTORY DOORS

Page 27: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.10

DOOR RESTRICTOR - CAM

1. Fasten door restrictor cam to strike side of mechanism, using provided hardware attached to door restrictor cam bracket.

Page 10 of 18

FIGURE 5.1

FIGURE 5.2

INSTALLATION OF LANDING ENTRANCEASSEMBLY OF LANDING ENTRANCE

ONE WORKER REQUIRED

18mm/ADJUSTABLE WRENCH, STANDARD HAMMER

STEP 6: ATTACH THE DOOR RESTRICTOR MAGNET, USE THE PART’S PROVIDED HARDWARE(NOT SHOWN IN LIST). THE RESTRICTOR MAGNET IS TO BEINSTALLED ON THE STRIKE(CLOSING) SIDE.

STRIKE SIDE

2 SPEED VICTORY DOORS

Page 28: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.11

INSTALLATION OF LANDING ENTRANCE MECHANISM BRACKETS

ONE WORKER REQUIRED

17mm WRENCH/ADJUSTABLE WRENCH

STEP 7: ATTACH MECHANISM SUPPORT BRACKETS AS SHOWN.

2 SPEED VICTORY DOORS

Page 29: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.12

TWO WORKERS REQUIRED

MARKING TOOL, DRILL AND HAMMERCONCRETE: 3/8” MASONRY DRILLWOOD: 3/8” X 3”LONG WOOD LAGS

ATTENTION: BE EXTRA CAREFUL WHEN INSTALLING THE ENTRANCE AS IT MAY NEED TO BE TILTED WHEN MOUNTING IN HOISTWAY.

INSTALLATION OF LANDING ENTRANCE INSTALLATION OF ENTRANCE

STEP 8: FIT THE LANDING FRAME INSIDE THE HOISTWAY, SECURE THE LANDING TO THE SILL SUPPORT TO THE SILL SUPPORT BRACKETS IN THE HOISTWAY. NOTE: REMOVE THE NUTS AND WASHERS FROM THE POST BRACKET. PLACE THE CARRIAGE BOLT THOUGH SILL AND REFASTEN.

ONCE SILL SUPPORT IS SECURED, FIT ANCHORS TO MECHANISM SUPPORT BRACKETS AND SECURE. DEPENDING ON APPLICATION USE APPROPRIATE ANCHORS AND TOOLS.

2 SPEED VICTORY DOORS

Page 30: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.13

LANDING FRAME – FLOOR ATTACHMENT

1. Unravel wire on mechanism. 2. Wrap wire around pulley and let hang along strike post.

3. Fasten bracket to sill and attach spring to bracket with hook, using landing frame return spring kit (item #10). 4. Slide door hanger open by 2 inches, stretch the spring enough to close the door hanger from this position, and then tie wire of spring.

Page 15 of 18

FIGURE 10.2

FIGURE 10.1

PULLEY

INSTALLATION OF LANDING ENTRANCE DOOR PANELS, LANDING MECHANISM WIRE

ONE WORKER REQUIRED

TENSION CABLE WIRE CRIMPERS(HEAVY DUTY)

STEP 9: TO INSTALL THE DOORS FOLLOW THE INSTRUCTIONS ON PAGES 5.06, 5.07 AND 5.08. ENSURE DOORS RUN FREELY ON LANDING SILL.

STEP 10: GUIDE THE CLOSING WIRE TO THE PULLEY. ONCE ITS ON THE PULLEY GUIDE THE WIRE AND TIE IT TO ONE END OF THE SPRING. ATTACH THE OTHER END OF THE SPRING TO THE BRACKET ON THE POST. SECURE THE WIRE AFTERWARDS WITH ITEM#15 - ALUMINUM CLIP (NOT SHOWN)

PULLEY

BRACKET

WIRE

HANGER

2 SPEED VICTORY DOORS

Page 31: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

6.14

INSTALLATION OF LANDING ENTRANCE TOE GUARD

ONE WORKER REQUIRED

3mm ALLEN KEY, 8mm WRENCH

STEP 11: MOUNT TOE GUARD TO SILL SUPPORT USING HARDWARE SHOWN BELOW.

AT THIS POINT, THE ENTRANCE SHOULD BE FULLY FUNCTIONAL WITH THE CAB OPERATOR, ALL DOOR PANELS SHOULD RUN SMOOTH, AND WHEN FULLY OPEN ALL PANELS SHOULD BE FLUSH TO EACH OTHER.

TOE GUARD

2 SPEED VICTORY DOORS

Page 32: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

CONSTRUCTION OF LANDING ENTRANCE WALLS TO THE FINISHED LANDING ELEVATOR

DOOR FRAMES

7.00

NOTE:

A. CAREFUL ATTENTION MUST BE GIVEN TO THIS PROCESS BOTH BY THE INSTALLING

ELEVATOR COMPANY AND THE GENERAL CONTRACTOR (GC) THAT IS TO FINISH OFF THE

LANDING ENTRANCE WALLS TO THE LANDING ELEVATOR ENTRANCES AFTER THE

ENTRANCES ARE SET IN POSITION BY THE INSTALLING ELEVATOR COMPANY.

B. THE ELEVATOR COMPANY RESPONSIBLE FOR THE INSTALLATION OF LANDING ENTRANCES

SHALL DISCUSS THESE SAFETY ISSUES WITH THE GC AND IT IS THE RESPONSIBILITY OF THE

GC TO DISCUSS THESE ISSUES WITH THE SUB TRADES COMPLETING THE LANDING

ENTRANCE WALLS TO THE LANDING ELEVATOR ENTRANCE.

1. MEET ON SITE WITH THE GENERAL CONTRACTOR (GC) THAT IS RESPONSIBLE FOR THE

CONSTRUCTION OF LANDING ENTRANCE WALLS TO THE LANDING ELEVATOR ENTRANCE

FRAME AND DEMONSTRATE THAT THE INTERFACE OF THE CAB DOORS, DOOR OPERATOR,

AND LANDING ENTRANCE DOORS WORK WITHOUT PROBLEMS. THEY MUST SEE THAT EACH

DOOR IS PROPERLY ALIGNED TO EACH OTHER AND THE CABS DOORS INTERFACE

PROPERLY TO EACH LANDING ENTRANCE WITHOUT INTERFERENCE.

2. LANDING ENTRANCE WALLS CAN BE FINISHED WITH EITHER DRYWALL (GYPSUM) OR

MASONRY AND WHEN USING EITHER ONE CAREFUL ATTENTION SHOULD BE PROVIDED

WHEN COMPLETING THIS WORK.

3. THE ELEVATOR COMPANY INSTALLING THE LANDING ELEVATOR ENTRANCE SHALL BE RE-

SPONSIBLE FOR PROVIDING THE APPROPRIATE DOCUMENT SHOWING EITHER THE MASON-

RY PROCESS OR DRYWALL PROCESS OF COMPLETING THE ENTRANCE WALLS.

4. THE INSTALLING ELEVATOR COMPANY SHALL BE RESPONSIBLE TO EXPLAIN TO THE GC

THAT THE PERSONS RESPONSIBLE FOR COMPLETING THE CONSTRUCTION OF THE EN-

TRANCE WALLS SHALL IN NO WAY DISTURB THE LOCATION OF FRAMES AS INSTALLED BY

THE ELEVATOR COMPANY.

2 SPEED VICTORY DOORS

Page 33: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

7.01

CONSTRUCTION OF LANDING ENTRANCE WALLS TO THE FINISHED LANDING ELEVATOR

DOOR FRAMES

5. DO NOT REMOVE THE PROTECTIVE COATING FROM THE DOORS OR THE FRAMES UNTIL

THE ENTRANCE WALLS ARE COMPLETELY FINISHED.

6. IF THE GC REQUESTS TO USE THE ELEVATOR AS A CONSTRUCTION ELEVATOR IT IS VERY

IMPORTANT THEY TAKE FULL RESPONSIBILITY FOR ANY DAMAGE AND THEY MUST ALSO BE

MADE FULLY AWARE OF ALL SAFETY ISSUES. IT IS THE RECOMMENDATION OF OLS THAT

ONE PERSON FROM THE INSTALLING ELEVATOR COMPANY IS PRESENT WHILE THE EN-

TRANCE WALLS ARE BEING BUILT.

7. ALL OSHA OR EQUIVALENT SAFETY STANDARDS MUST BE FOLLOWED BY THE ELEVA-

TOR INSTALLING COMPANY AND THE GENERAL CONTRACTOR AS REQUIRED BY THE LOCAL

ENFORCING AUTHORITIES. IF FALL ARREST TRAINING IS REQUIRED TO BE GIVEN TO THE

WORKERS BEFORE STARTING TO WORK THIS MUST BE COMPLETED PRIOR TO STARTING

THE WORK AND THE FALL ARREST EQUIPMENT MUST BE MADE AVAILABLE IF NECESSARY.

EACH LANDING ENTRANCE MUST BE BARRICADED WITH OSHA STANDARD BARRICADES

AND NOT REMOVED UNTIL SUCH TIME AS THE ENTRANCE WALLS ARE COMPLETED AND IT

IS SAFE TO DO SO

8. UNDER NO CIRCUMSTANCE SHOULD SAFETY BE COMPROMISED, IT IS AN ABSOLUTE

REQUIREMENT THAT ALL PERSONNEL ARE TRAINED TO ALL THE NECESSARY SAFETY

STANDARDS WHILE INSTALLING THE ELEVATOR OR WORKING IN CLOSE PROXIMITY TO

THE ELEVATOR. IT IS THE RESPONSIBILITY OF THE INSTALLING ELEVATOR COMPANY, IT’S

EMPLOYEES, THE GENERAL CONTRACTOR, AND IT’S SUB TRADES THAT ALL EMPLOYEES

WORK SAFELY.

9. OLS TAKES ABSOLUTELY NO RESPONSIBLY FOR TRAINING THE ELEVATOR COMPANY

INSTALLING THE ENTRANCES OR THE COMPANY RESPONSIBLE FOR CONSTRUCTING THE

ENTRANCE WALL TO THE ELEVATOR LANDING ENTRANCE.

2 SPEED VICTORY DOORS

Page 34: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

8.00������

ELECTRICAL DIAGRAM OF BOARD

Auto-Learn can also beAccomplished by the following:

1. Remove power supply2. Jump JP23. Re-attach power supply4. Auto-Learn will take place5. Remove jumper6. Complete

Board Calibration

2 SPEED VICTORY DOORS

Page 35: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

8.01 ������

ELECTRICAL DIAGRAM OF BOARD - MAIN CONNECTIONS

JP6

JP1 24V DC ONLY

JP8

JP16

JP17

JP10JP11

AUTO-LEARN

JP4

2 SPEED VICTORY DOORS

Page 36: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

SET UP OF THE CONTROL BOARD

9.00

SET UP OF THE VICTORY CONTROL BOARD Please ensure of the following before setting the doors.

Guide shoes in place Cleanliness of lines and ways Any damage to the door panels, operator, control board etc. Electric contacts to the control board Cleanliness of the mating and sliding wheels and relevant guide ways

WARNING

Do not lubricate the guide ways Do not lubricate the transmission belts Do not lubricate the wheel bearings

The Victory Doors control boards comes pre-programmed and pre-wired. Please make the connections to the terminals as follows. Connector JP 1(L1 – L2) L1(+) with Ferrites L2 (-) with Ferrites Ensure that 24V DC is supplied to the Victory Doors control board. Connector JP2 Data acquisition/Auto-learn For every test and adjustment ALWAYS do an auto-learn cycle. An Auto-Learn cycle is can be done removing the power.

1. Jump JP2 with provided jumper 2. Power up the board 3. Let the cycle run 4. Remove the Jumper

Connector JP4 Connection for programming tool To change the parameters in the control board connect the programming tool to JP4 and set the switch to (P). Use the (+) and (-) buttons to search through the parameters. Press (S) to select the parameter and adjust with (+) and (-) buttons. Press (T) to test any function changed. Once finished put the programmer back to (N) and continue with the adjustment of the Door. Connector JP6 (M1 – M2) Motor Connection – Connect motor to here. On a RH Operator ensure that M1=Red and M2=Black. On a LH Operator ensure that M1=Black and M2=Red. Connector JP8 (F1 – F2) Closing Contacts and Optic Barrier Parameter U1=00 optic barrier input (contact NA) Parameter U1=01 input of the end of closing contact Normally U1=01

2 SPEED VICTORY DOORS

Page 37: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

9.01

SET UP OF THE VICTORY CONTROL BOARD Please ensure of the following before setting the doors.

Guide shoes in place Cleanliness of lines and ways Any damage to the door panels, operator, control board etc. Electric contacts to the control board Cleanliness of the mating and sliding wheels and relevant guide ways

WARNING

Do not lubricate the guide ways Do not lubricate the transmission belts Do not lubricate the wheel bearings

The Victory Doors control boards comes pre-programmed and pre-wired. Please make the connections to the terminals as follows. Connector JP 1(L1 – L2) L1(+) with Ferrites L2 (-) with Ferrites Ensure that 24V DC is supplied to the Victory Doors control board. Connector JP2 Data acquisition/Auto-learn For every test and adjustment ALWAYS do an auto-learn cycle. An Auto-Learn cycle is can be done removing the power.

1. Jump JP2 with provided jumper 2. Power up the board 3. Let the cycle run 4. Remove the Jumper

Connector JP4 Connection for programming tool To change the parameters in the control board connect the programming tool to JP4 and set the switch to (P). Use the (+) and (-) buttons to search through the parameters. Press (S) to select the parameter and adjust with (+) and (-) buttons. Press (T) to test any function changed. Once finished put the programmer back to (N) and continue with the adjustment of the Door. Connector JP6 (M1 – M2) Motor Connection – Connect motor to here. On a RH Operator ensure that M1=Red and M2=Black. On a LH Operator ensure that M1=Black and M2=Red. Connector JP8 (F1 – F2) Closing Contacts and Optic Barrier Parameter U1=00 optic barrier input (contact NA) Parameter U1=01 input of the end of closing contact Normally U1=01

ATTENTION: DURING THE FIRST POWER UP OF THE VICTORY DOORS CONTROL BOARD PLEASE PRESS THE CALIBRATION BUTTON WITH JP10 AND JP11 DISCONNECTED. THE CALIBRATION BUTTON CAN ALSO BE USED TO CLEAR THE BOARD OF SETTINGS AND SET TO FACTORY DEFAULTS. Connector JP10 (FCA – FCC – CAM) Output of the following information on the NC contacts for the operation panel: 1 - Opening limit switch terminals 1 and 2 – FCA (Open) 2 - Closing limit switch terminals 3 and 4 – FCC (Closing) 3 - Photocell or sensitive edge intervention terminals 5 and 6 – CAM Connector JP11 (TAP – TCP – EXF – COM) Door opening/closing management 1 - Opening command from the panel Terminal / TAP 2 - Closing command from the panel Terminal / TCP 3 - Command of photocell by-pass for fireman service Terminal / EXF 4 - Negative in output (24 Volts/0 Volts) Terminal / COM Manual commands can be given to the above by a 0v signal. Connector JP16 (CPA) Open limit sensor Connector JP17 (ENC.M) Encoder Connection The Victory Doors control board had been set up to the following parameters. If changes are necessary on the field, the following parameters are listed as follows. (Table) V1.6 Connection of the Light Curtains (OLS Supplied): The light curtains have reverse polarity and short circuit protection. Please refer to the following diagrams to ensure proper connection to your controller. Transmitter Receiver Please refer to the following diagram if you want to connect your (OLS Supplied) light curtains to the board. Please also used the connector provided.

SET UP OF THE CONTROL BOARD

NOTE: PROGRAMMING TOOL NOT INCLUDED

2 SPEED VICTORY DOORS

Page 38: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

PART No.127539

NOTE:

COMPONENT SPECIFICATION DESCRIPTION: DOOR OPERATOR

CHARACTERISTICS: 900mm 3 SPEED, LH, DOOR OPERATOR

SPECIFIED BY:ANDY L.

DATE:OCT 25/07

PAGE No.1 OF 1

1. HAND - NORTH AMERICAN L/H EUROPEAN R/H2. EXTRA 15mm TRAVEL WITH ENCODER3. CSA APPROVED CONTROL AND DOOR INTERLOCK4. FITTED WITH NORTH AMERICAN DOOR RESTRICTOR5. ALL DRIVE BELTS TO BE POSITIVE TOOTHED BELTS6. DOOR PARAMATERS TO BE SET TO SPEC (SEE SPECS V1.6)7. 1220mm LONG CAR SILL WITH 900mm TRANSITION PIECE 8. TOE GUARD 940x150mm9. NORTH AMERICAN DOUBLE DOOR CONTACT10. 2 DOOR OPERATOR MOUNTING BRACKETS (SEE FIG. 1)11. PROVIDE STANDARD HARDWARE (SEE HARDWARE LIST)12. PACKAGE ALL HARDWARE IN PLASTIC BAG13. PACKAGE ALL ITEMS INCLUDING THE DOOR OPERATOR IN A CARDBOARD BOX 14. AFFIX LABEL ON BOX SHOWING OLS PART NUMBER & VICTORY DOOR PART NUMBER

VICTORY DOOR PARAMATERS (OLS DESIGN) V1.6CODE DESCRIPTION MIN MAX DEFAULT NOTE

P0 OPENING SPEED 15 25 20

P1 CLOSING SPEED 10 25 20 P2 CLOSING FORCE LIMIT 10 25 15 P3 FINAL OPENING SPEED 4 12 5 P4 FINAL CLOSING SPEED 2 12 5 P5 INITIAL ("RELEASE") OPENING SPEED 9 16 10 P6 OPEN DOOR HOLDING FORCE 8 14 10 P7 CLOSED DOOR HOLDING FORCE 8 14 12 P8 DISTANCE TRAVELED AT OPENING SPEED 10 20 12 P9 ACCELERATION TIME (OPEN/CLOSE) 2 10 5 PA SPEED CONTROL TIME PERIOD 10 25 18

PB LIGHT CURTAIN DISABLE DISTANCE 10 25 15

PCPHOTO CELL SELECTION 0=BYPASS, 1=ACTIVE, 3=DEFAULT 0

PDACCELETARION DISTANCE 1=SHORT, 2=NORMAL, 3=LONG 1 3 2

PE DISTANCE COVERED AT LOW SPEED TO COMPLETE OPENING 4 16 7

PF DISTANCE COVERED AT LOW SPEED TO COMPLETE CLOSING 10 25 15

U0 MAX CLOSING SPEED IN FIRE RECALL PH-1 10 25 10

U1INPUT F1-F2 PHOTCELL=0, DOOR CLOSED=1 0 1 1

U2DOOR OPEN SIGNAL PULSE=0, SUSTAINED=1 0 1 1

U3ENCODER LOCATION MOTOR=0(-) OR 1(+), PULLEY=6(N/A) 1

U4DOOR RE-OPENING DEVICE CONNECTIONTO DOOR OPERATOR=0 TO CONTROL PANEL=1

1

U5 RAMP UP CURRENT 5 25 10

HARDWARE LIST# DESCRIPTION QTY IMAGE

1 PLAIN WASHER OD=20 - M10 15

2 TOOTHED WASHER - M10 21

3 PLAIN WASHER OD=30 - M10 6

4 SPLIT LOCK WASHER - M10 6

5 CARRAGE BOLT - M10x25 6

6 HEX NUT - M10 6

7 FLAT HEAD SOCKET CAP SCREW - M10x30 4

8 TOOTHED CROWN WASHER - M10 4

9 CAGE NUT 5/47- M10 (USED WITH FIG 1) 4

10 CAGE NUT (STANDARD) - M10 21

11 SOCKET HEAD CAP SCREW - M10x15 21

12 ECCENTRIC WASHER - M10 6

13 SHIMS - 1mm & 2mm THICK 15 SETS

14BUTTON HEAD SOCKET CAP SCREW - M5x10 (FOR TOE GUARD) 3

15SERRATED FLANGE HEX NUT - M5 (FOR TOE GUARD) 3

16 GIB/GUIDE (WITH RUBBER) 6FIG. 1BOX DIMENSIONS: 148x59x19cm

AFFIX LABEL HERE

REVISION HISTORYREV DESCRIPTION DATE APPROVED E.R.#

** PLEASE REFER TO DOC# 151897 FOR PROGRAM LOAD PROCEDURE

CONTROL BOARD PARAMETERS V1.6

9.02

2 SPEED VICTORY DOORS

Page 39: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

OPERATOR RUNNING CYCLE

9.03

SPEED

SPEED

TIME

TIME

OPENING CYCLECLOSED DOOROPEN DOOR

CLOSING CYCLECLOSED DOOROPEN DOOR

2 SPEED VICTORY DOORS

Page 40: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

TROUBLESHOOTING

10.00

After completing auto learn (data acquisition cycle) cycle, doors will continually open and close.

i. Using programming device, go through program parameters to ensure that values are all set to default. Modifying many parameters at once may cause this. Ensure that auto learn is performed after every change.

Doors will close but FA (door open sensor) light will remain lit on door operator board. Doors will open but FC (door close sensor) light will remain lit on door operator board.

i. Ensure door contacts are connected to JP8 (F1 & F2) and the reed sensor connected to JP16 (CPA). Reversing the two will cause this respective problem.

The LED’s on the door operator board do not turn on.

i. Ensure that the power supply is plugged into location JP1 (L1 positive & L2 negative)

ii. Ensure the voltage supplied is 24v DC iii. Ensure the fuse located at F2 is still good. If not,

replace using a 4 amp quick fuse. The door will not open when instructed to by the controller.

i.Perform data acquisition cycle as per section 6.0. Retry door open instruction.

ii. Ensure controller sends a 0v signal when instructing doors to open on TAP.

iii. Disconnect connector JP11 (TAP – TCP – EXF – COM). Jumper (hold jumper) pins COM to TAP on Victory board.

iv. Jumper pins COM to TCP; if doors open then motor polarity has been reversed.

v. If the door forces itself to close in the closed position, Check the signals coming from the controller.

The doors will not close when instructed to by the controller.

i. Perform data acquisition cycle as per section 6.0. Retry door close instruction.

ii. Ensure controller sends a 0v signal when instructing doors to close on TCP.

iii. Disconnect connector JP11 (TAP – TCP – EXF – COM). Jumper pins COM to TCP on Victory board.

iv. Jumper pins COM to TAP; if doors close then the polarity of the motor has been reversed.

v. If the door forces itself to open in the open position, check the signals coming from controller.

No response to open / close instruction from controller.

i. Perform data acquisition cycle, as per section 6.0. Retry door instructions from controller.

ii. Ensure ground is connected to main controller. If not, door operator will not respond to open / close signals.

iii. Ensure that controller is supplying a 0v signal.

2 SPEED VICTORY DOORS

Page 41: 2 SPEED VICTORY DOORS 2 SPEED VICTORY DOOR HOME ELEVATOR ... SPEED NON F.R... · 2 SPEED VICTORY DOOR HOME ELEVATOR ENTRANCES NON FIRE RATED Number One In Fluitronic Elevator Components

10.01

Please contact Technical Support at 1-800-567-3557 for any questions.

TROUBLESHOOTINGDoors will not shut fully and the clutch (skate) will not fully collapse.

i. Plug programming device into terminal JP4. Increase the values of parameters U5, P7 and P2 (programming instructions as per section 5.0). Perform data acquisition cycle (section 6.0) to reset door operator. Re try.

ii. Ensure that installation of the operator has been done properly, the clutch must make contact with skate.

Doors will shake when closing. i. Ensure that doors have been installed to 1/4” of the ground. After that raise doors by 1/8”.

ii. Ensure that the encoder is plugged into JP17 (ENC.M.). Perform data acquisition (section 6.0). Re try.

iii. If rattling is occurring, check guide shoes (Figure 2.3.1). LED FC will not turn on when doors are closed and car gate signal not ok when doors are closed

i. Check continuity between the two wires of the door contact switch when doors are closed. If continuity does not exist, adjust the position of the contacts in order to ensure contact when doors are closed.

ii. Check for damage on the contacts. If damaged replace contacts.

Doors are moving extremely slow, cannot fully close / open.

i. Ensure the belt for the encoder is not too tight. Allow 1cm compression from both sides when belt is squeezed with two fingers.

ii. Ensure belt for motor is not too tight. Allow belt to compress a minimum of 1cm from both sides when squeezed with two fingers.

iii. Ensure that Auto learn cycle has been performed after changes, too many changes to the parameters without performing auto learn will cause this problem.

Overheating occurs

i. Ensure that motor polarities are not reversed. Reversed polarities will cause board to over heat.

Parameter E”X” shows up on the programming tool. Where X is a number from 0 9

i. An Error has occurred within the board. Power down and remove all connections to Victory Control board. Attach all connections and perform Auto learn once more, Please set all parameters to default and restart the setting up of the doors.

2 SPEED VICTORY DOORS