This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
・All specifications are subject to change without notice.
1
CC 3 - 05 05 S F -E■ Features
●Mounting area halved compared to existing products●Nonuse of tantalum capacitor or aluminum electro-
lytic capacitor●Remote On/Off function incorporated in all series of
products
●5-side metal-shielded low noise design●Lightweight design with no resin filled up
●Supports DIP insertion,SMD mounting and SIP vertical insertion (3W products)
CC-E
■ Product Line up
Insulation type DC-DC converter
■ Applications
■ Model-naming method
Shape
Symbol for number of outputsS: Single output, D: Dual outputsNominal output voltage03: 3.3V, 05: 5V, 12: 12V
Maximum output power1R5: 1.5W, 3: 3W, 6: 6W, 10: 10W
Representing series name by combination with "-E"at the end
Output power
Input voltage
Model name (output voltage: 3.3V)
Model name (output voltage: 5V)
Model name (output voltage: 12V/15V)
Model name
Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type Output current DIP type SMD type SIP type
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % ± 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ minApproved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC1R5-E2
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % ± 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ minApproved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC1R5-E
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 5 0 00 0 0 0 0 050Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0°C to 50°C 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p i e D mm D : 5 5 MD: 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC1R5-E
Between input terminal and output terminal: 500VDC, 50MΩ min
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
3
・All specifications are subject to change without notice.
4
Derating Curve
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagramE-xDxxxx-5R1CCE-xSxxxx-5R1CC
16.6±0.2
12.71.905 1.905
t=0.3
8.5m
ax.
3.5
( 3.2
2)( 3
.22)
2.54
7.62
16.51
12.7
4.0
2.54
5.08
2.54
3
a b
2
1
7-0.3×0.6
b a
4
5
7
6
2.7
1.0
2.7
0.5
3.5
a
b
2.54
5.08
2.54
14.605
7.62
10.1
6
13.0
8
2.92
16.51
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
16.6±0.2
t=0.38.8m
ax.
16.51
4.0
Coplanarity: 0.1 or lower19.81
1.81.8
( 3.2
2)( 3
.22)
2.54
7.62
2.54
5.08
2.54
3
2
1
4
5
7
67-0.3×0.6
2.54
5.08
2.54
7.62
10.1
6
( 13.
38)
( 3.2
2)
22.0
3.2 3.215.61.
2
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC3-E(DIP/SMD)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
4
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC3-E(DIP/SMD)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
5
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC3-E(DIP/SMD)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
6
・All specifications are subject to change without notice.
7
a b
Ambient temperature (°C)
Out
put p
ower
(%)
a:0.5m/s(100LFM)b:1m/s(200LFM)
Natural air cooling
-40 -20 0 20 40 60 80 100
100
80
60
40
20
0
Output power derating by ambient temperature (common specification)
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagramE-xDxxxx-3CCE-xSxxxx-3CC
17.78 45.245.2
( 3.2
2)( 3
.22)
2.54
7.62
2.54
5.08
2.54
3
a b
2
1
7-0.3× 0.6
ab
4
5
7
6
a
b
8.5m
ax.
3.5
22.86
17.78
16.6±0.2
t=0.3
4.0
2.54
5.08
2.54
20.32
7.62
10.1
6
13.0
8
2.92
22.86
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
26.16
8.18.1
( 3.2
2)( 3
.22)
2.54
7.62
2.54
5.08
2.54
3
2
1
7-0.3× 0.6
4
5
7
6
8.8m
ax.
22.86
16.6±0.2
t=0.3
4.0
Coplanarity: 0.1 or lower
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p i e D mm
ote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p i e D mm
ote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC3-E(SIP)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
8
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 0 00 0 00 0 50 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p i e D mm
ote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5Ma imum Current 0 00 0 00 0 5 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0Ma imum oad e ulation 0 00 load mV 0 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e
tandard a et tandard
Me ani al ei t t p i e D mm
ote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC3-E(SIP)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
9
・All specifications are subject to change without notice.
10
Outline Drawing
CC3-xxxxxS-E (SIP type)
CC3-E(SIP)
E-SDxxxx-3CCE-SSxxxx-3CC
2.47 P P P P 2P P P P 6
3.5
( 0.5
)
4.1
( 0.5
)
17.9
4
17.78 5.01
2.47
22.86t=0.25
a0.
5
P=2.54
9.2
9.2
27.8
a
1 2 3 4 5 7 8 9 10
Internal parts mounting space
17.78
2.47 22.86 2.47
27.8
P P P P 2P
P=2.54
P P P
6.0
9.2
9-ø0.8 (land diameter ø2.0)
2-ø1.5 (land diameter ø2.5)
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
ominal Volta e VDC 5 5 5Ma imum Current 00 000 0 500 0 00 0 50 0 00Ma imum ower 5Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 00 0 500 0 00 0 50 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°C e ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC6-E
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
11
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 00 0 500 0 00 0 50 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 00 0 500 0 00 0 50 0 00Ma imum ower Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 5i e D mm D : 5 MD:
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC6-E
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
・All specifications are subject to change without notice.
13
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagramE-xDxxxx-6CCE-xSxxxx-6CC
8.5m
ax.
3.5
22.86
17.78
21.1±0.2
t=0.3
4.0
45.245.2
( 2.9
3)5.
08( 2
.93)
10.1
6
5.08
5.08
5.08
3a b
2
1
7-0.3×0.6
ab
4
5
7
6
b
a
5.08
5.08
5.08
20.32
10.1
6
15.2
4
17.8
7
2.63
22.86
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
8.8m
ax.
22.86
21.1±0.2
t=0.3
4.0
Coplanarity: 0.1 or lower26.16
8.18.1
( 2.9
3)( 2
.93)
10.1
65.
08
5.08
5.08
5.08
3
2
1
7-0.3×0.6
4
5
7
6
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
ominal Volta e VDC 5 5 5Ma imum Current 500 000 0 00 0 0 0 00 0 0Ma imum ower 5 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 500 000 000 00 50 0Ma imum ower 5 0 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC10-E
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
14
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 500 000 0 00 0 0 0 00 0 0Ma imum ower 5 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ientm ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum ℃ in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ualutput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°Cutput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 500 000 000 00 50 0Ma imum ower 5 0 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ualutput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°Cutput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC10-E
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
・All specifications are subject to change without notice.
ominal Volta e VDC 5 5 5Ma imum Current 500 000 000 0 00 0 50 0 0Ma imum ower 5 0 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
ominal Volta e VDC 5 5 5Ma imum Current 500 000 000 0 00 0 50 0 0Ma imum ower 5 0 0Ma imum ine e ulation it in input olta e ran e mV 0 0 0Ma imum oad e ulation 0 00 load mV 0 00 00emperature Coe i ient m ient temperature 0℃ to 50℃ 0mV 00mV 00mV
Ma ower otal e ulation ma % 5Ma imum ipple oi e t p ma 5 mVp p 0 0 0 0Volta e d u ta le an e VDC 5 5 0 5 0 5 0
un tioner Current rote tion aila leer Volta e rote tion ot a aila le
emote Control aila le
n ironment
℃ 0 to 5℃ 0 to 5
% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured% 5 5 t e ondition o ma imum °C in wet ul temperature and non onden ation ould e en ured
Vi ration 0 55 , 5 minute weep and 5 mm total amplitude, dire tion , or eao 0m 00 , m , dire tion , time or ea , in non operation
olation it tand Volta e Between input terminal and a e, etween input terminal and output terminal, and etween output terminal and a e: 500V C or minuteolation e i tan e Between input terminal and output terminal: 500VDC, 50MΩ min
tandard a et tandard
Me ani al ei t t p 0i e D mm D : 5 5 5 MD: 5 5
ote: in model name i to e repla ed a m ol w i repre ent t e terminal on i uration : D : MD or a tual model nameote: it nominal input output olta e, ma imum output urrent, and a 5°C, i not pe i ied eparatelote: ± ±ote: or V model, output olta e an e et to V or 0V in le output ma in t e C M terminal open
it nominal input olta e, ma imum output urrent, and a 5°Ce ma imum output power alue i etween 0°C and 50°C or u e in out ide t i temperature ran e, deratin i needed
n alan ed load or dual output alan ed load mean a ondition w ere t e output and output o load urrent are e ual utput olta e in lude input an e, load an e alan ed load , and temperature an e
5 n 50M , a 5°C utput urrent re tri tion met od utomati all re ume w en t e au e are remo ed e er operate t e unit under output orted or o erload ondition or o er 0
e ond
CC10-E
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
Approved by UL62368-1, CSA62368-1, EN62368-1, UL60950-1, CSA60950-1, EN60950-1. (Expire date of 60950-1: 20/12/2020)
15
・All specifications are subject to change without notice.
16
Shape/Dimensions
Shape/Dimensions
Recommended measurements for mounting board
Recommended measurements for mounting board
Connection diagramE-xDxxxx-01CCE-xSxxxx-01CC
8.5m
ax.
3.5
35.56
25.4
22.6±0.2
t=0.3
4.0
25.4 80.580.5
( 3.6
8)( 3
.68)
5.08
10.1
6
5.08
5.08
5.08
3
2
1
7-0.3×0.6
4
5
7
6
a
b
b
a
30.48
3.38
18.6
2 10.1
6
15.2
4 5.08
5.08
5.08
2-ø1.5 (land diameter ø2.5)
7-ø1.0 (land diameter ø2.0)
35.56
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
35.56
22.6±0.2
t=0.3
4.0
38.86
8.18.1
( 3.6
8)( 3
.68)
5.08
10.1
6
5.08
5.08
5.08
8.8m
ax.
3
2
1
7-0.3×0.6
4
5
7
6
5.08
5.08
5.081.
2
( 3.6
8)
( 18.
92)
10.1
6
15.2
4
41.0
3.2 34.6 3.2
Unit: mmAllowable tolerance is ±0.5 if not specified separately.
Terminal connectionsNo.1 +VinNo.2 RCNo.3 –VinNo.4 –VoutNo.5 Common outNo.6 TRMNo.7 +Vout
Coplanarity: 0.1 or lower
Outer shape of product
LoadLoad
Load
Outer shape of product
Outline Drawing
CC10-xxxxxF-E (DIP type)
CC10-xxxxxR-E (SMD type)
CC10-E
a b
Ambient temperature (°C)
Out
put p
ower
(%)
a:0.5m/s(100LFM)b:1m/s(200LFM)
Natural air cooling
-40 -20 0 20 40 60 80 100
100
80
60
40
20
0
Output power derating by ambient temperature (common specification)
Derating Curve
5.08
a
b
2.7
2.7
1.0
0.5
3.5
0.5
CC-E
・All specifications are subject to change without notice.
17
CC-E Instruction Manual
1. Remote On/Off terminal (RC)
Open collector is recommended as the connection system. Consult us for use with other systems.Use a transistor with "VCE: Vin or over" and "Ic: 1mA orover".Output is switched off by setting the RC terminal open, andswitched on by setting the RC terminal to LOW (0-0.4V).
RCcontrolsignal
+Vin +Vout
–Vin –Vout
RC
Load
When not using this function (always on), short-circuit be-tween RC terminal and -Vin terminal.
+Vin +Vout
–Vin –Vout
RC
When notusing thisfunction (always on)
Load
1-2. Output voltage adjusting ter-minal (TRM)
Output voltage can be set to the values shown in the figurebelow by connecting the TRM terminal to the -Vout termi-nal.When not using this function, set the TRM terminal to open.Note that when the output voltage is set high by this func-tion, derating of output current is necessary according tothe maximum power.
DIP/SMDmodels
To be replaced with 1R5(1.5W), 3(3W), 6(6W), or 10(10W) for actual model names.
Model name Open Connection to -Vout Fig.CC –xx03Sx–E 3.3V 3.6V 1CC –xx05Sx–E 5V 6V 1CC –xx12Sx–E 12V 15V 1CC –xx12Dx–E ±12V ±15V 2
Fig.1
Fig.2
+Vin +Vout
TRM
–Vin –Vout
+Vin
–Vin –Vout
TRM
+Vout3.3V5V12V
3.6V6V15V
+Vin +Vout
TRM
COM
–Vin –Vout
+Vin
–Vin –Vout
+Vout
Load
Load
Load
LoadTRM
COM
+12V
–12V
+15V
–15V
Load
Load
SIPmodelsModel name Model name Connection to -Vout Fig.CC3–xx03SS–E 3.3V 3.67V 3CC3–xx05SS–E 5V 6V 3CC3–xx12SS–E 12V 15V 3CC3–xx12DS–E ±12V ±15V 4
Fig.3
Fig.4
+Vin
+Vou
t
TRM
–Vin
–Vou
t
Load Load
+Vin
+Vou
t
TRM
–Vin
–Vou
t
3.3V, 5V, V76.3V21 , 6V, 15V
+Vin
+Vou
t
TRM
–Vin
–Vou
t
Load Load
CO
M
+Vin
+Vou
t
TRM
–Vin
–Vou
t
Load Load
CO
M
+12V –12V +15V –15V
1. Control functions/Protection functions/Connections