THE NATIONALBUILDING CODE (CONDO)

DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. SANTOS, KITTTEMPLO, CHARMAINE Y.

CLASSIFICATION AND GENERAL REQUIREMENTS OF ALL BUILDINGSBY USE OR OCCUPANCY

USE OR OCCUPANCYUNIT AREA PER OCCUPANT(Sq. m.)Minimum of Two Exits other than elevators are required where number of occupant is over

A. Dwellings2810

B. Hotels18.610

Apartments18.610

Dormitories18.610

National Building Code of the Philippines

GROUP A RESIDENTIAL DWELLINGSSection 701

OCCUPANCY TYPE

GROUP B RESIDENTIAL, HOTEL, AND APARTMENTS

Section 702

No change shall be made in the character of occupancy of any building.

Section 703

One-storey building with more than one occupancy each portion shall conform to the requirement of each.

http://continuingeducation.construction.com/article.php

1.) One Hour Fire Resistive Operation

2.)Two Hour Fire resistive Operation

3.)Three Hour Fire ResistiveOperation

4.)Four Hour Fire Resistive Operation

TYPES OF OCCUPANCYSEPARATION

LOCATION ON PROPERTYNo buildings shall be constructed unless it adjoins a street

National Building Code of the PhilippinesLOCATION ON PROPERTY

LOCATION ON PROPERTY

LOCATION ON PROPERTY

MAXIMUM HEIGHT OFBUILDINGS

MAXIMUM HEIGHT OFBUILDINGS

MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY

MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY

National Building Code of the Philippines

MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY

National Building Code of the Philippines

SETBACK REQUIREMENT

YARDType of Residential Use / Occupancy

R - 1(meters)R - 2R - 3R - 4(individual lot / unit meters)R - 5(meters)

Basic(meters)Maximum(meters)Basic(meters)Maximum(meters)

Front4.503.008.00*3.008.00*4.506.00

Side2.002.00**2.00*****2.00(optional)2.00(optional)3.00

Rear2.002.002.00***2.002.003.00

National Building Code of the Philippines

PARKING REQUIREMENT

3.60m * 12.00m bus/tracks

PARKING REQUIREMENT

PARKING REQUIREMENT

1.20 M

3.70 M

ELEVATOR

10.1 ACCESSIBLE ELEVATOR SHOULD BE LOCATED NOT MORE THAN 30.00 M FROM THE ENTRANCEAND SHOULD BE EASY TO LOCATE WITH THE AID OF SIGNS

10.2 ACCESSIBLE ELEVATORS SHALL HAVE A MINIMUM DIMENSION OF 1.10 M. x 1.4 M.

National Building Code of the Philippines

CEILING HEIGHTS

Min. 2.10 m

Min. 2.40 m

Min. 2.40 m

Min. 2.70m

National Building Code of the Philippines

CEILING HEIGHTS1st Floor w/ Natural VentilationMin. 2.70 m

MEZZANINE FLOORS

Min. 1.80 m.

Stairways 1

National Building Code of the Philippines

0.90 m

SIZE AND DIMENSIONSOF ROOMSMin.Area = 1.20 sq. m

National Building Code of the Philippines

PWD BATHROOM

30 M

KITCHEN

WINDOW OPENING

10 % FLOOR AREA

MIN. 3.00 M

ARCADEARCADE

BUILDING PROJECTION OVER PUBLIC STREETS

CORRIDORS

3.4 A MINIMUM CLEAR LEVEL SPACE OF 1.50 M X 1.50 M SHALL BE PROVIDED BEFORE EXTENDING BEYOND A DOOR;

EXCEPTION: WHERE A DOOR SHALL OPEN ONTO BUT NOT INTO A CORRIDOR, THE REQUIRED CLEAR, LEVEL SPACE ON THE CORRIDOR SIDE OF THE DOOR MAY BE A MINIMUM OF 1.20M CORRIDOR WIDTH

3.5) PROTECTION SHOULD BE PROVIDED FROM DOORS THAT SWING INTO CORRIDORS

RAMPS

1:12 RATIONational Building Code of the Philippines

STAIRWAYS

C

AB

National Building Code of the PhilippinesSTAIRLANDING

Min. 2.00m

max.3.60 m

Max. 1.20 m

HANDRAIL

3 m3 m

0.80 m < x > 0.90 m

EXITS

Total Width of Exits > total occupant load served / 165

OCCUPANT LOADNO. OF EXITS

Above first storey More than 102

500-9993

1000 or more4

Occupant load of morethan 10

EXIT 1EXIT 2

National Building Code of the Philippines

Exit 1Exit 2500 999 Occupant Load

EXIT DISTANCES EXIT< 1/5 EXIT

National Building Code of the Philipp

EXIT

National Building Code of the Philipp

10.7 lux

MIN OF 1.10 M

National Building Code of the Philipp

MIN OF 2 MHazardous Areas/ 50 ormore loadDOOR EXIT

NATIONAL BUILDING CODE OF THE PHILIPPINES(Mall)

DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. SANTOS, KEITH L.TEMPLO, CHARMAINE Y.

Building Occupancy Group E:Business & Mercantile

National Building Code of the Philippine

Building TypeNumber of parking slotMarkets1 slot/150 sq.m. of shopping floor areaRestaurants, Fast-food centers,bars and beerhouses1 slot/30 sq.m. of customer areaOffice buildings1 slot/125 sq.m. of gross floor areaOther buildings in business/ commercial zones1 slot/125 sq.m. of gross floor areaPublic assembly buildings (theaters, cinemas, auditorium, stadium, etc.)1 slot/50 sq.m. of spectators areaBuilding Type (Recreational Facilities)Number of parking slotBowling Alleys1 slot/4 alleysAmusement center1 slot/50 sq.m. of gross floor areaPARKING REQUIREMENTS

PERPENDICULAR PARKING

5.00m2.40m

PARALLEL PARKING

2.00m6.00m

12.00m3.60m5.00m2.40m

Truck and Bus

Diagonal Parking

PARKING FOR PWD 1 accessible parking slot for the handicapped per 50 parking lots up to 150 slots and an additional slot for every 100 slots served.Maximum distance of accessible parking area from facility served. Parking areas for the physically handicapped shall be within 60.00m of the facility being

FACILITY SERVED

WALKWAY

PARKING SLOT

PARKING SLOT

PARKING SLOT

PARKING SLOT

PARKING SLOT

ONE WAY3.00mTWO WAY7.20m13.50m5.70m2.55m to 2.70m

90 DEG. PARKING BAY ONE SIDE

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

ONE WAY 3.00m

19.00m to 19.50m

TWO WAY7.20m

5.70m

2.55m to 2.70m

90 DEG. PARKINGBAY TWO SIDES

DABCXYZ9018.605.707.2018.605.707.206018.006.305.4016.655.655.404515.805.803.9013.854.973.90 Planning and Designers Handbook (Second Edition)

Max B. Fajardo Jr.

R = 17.00mto 21.00m

UP

4.00m toDN4.50m

4.00m to 4.50m

Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.

Bus

17.60m

2.10m

2.70m

7.60m

3.00m

Section 1207. Stairs, Exits, and Occupant Loads

C 1: Exit Door shall swing in the direction of travel. Double Acting Doors shall not be used as exits.

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant Loads C-3: Exit doorway shall be of a size as to permit the installation of a door not less than 900mm and not less than 2.00m in height

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and Occupant Loads C-5: Revolving, sliding, and overhead doors shall not be used as required exits.

Section 1207. Stairs, Exits, and Occupant Loads D-1: Every corridor or exit balcony shall not beless than 1.10 meters in width

NATIONAL BUILDING CODE OF THE PHILIPINES

Section 1207. Stairs, Exits, and OccupantLoads D-3: When more than one exit is required, they shallbe arranged to allow going to either direction fromany point in the corridor.

Section 1207. Stairs, Exits, and OccupantLoads Corridors and exterior exit balconies with dead endsare permitted when the dead end does not exceed6.00 meters in length

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and OccupantLoads E-1: Stairway widths Occupant Load (X) = Minimum WidthX > 50= 1100MMX < 50= 900MMX < 10= 750MM

ore than 100MMTrim and handrails shall not reduce the required width by m

Section 1207. Stairs, Exits, and OccupantLoads E-3: Winding stairways may be used if the requiredwidth of the run is provided at a point not more than 300MM from the side where the treads are

narrower.NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and OccupantLoads E-5: Every landing shall be a dimension measured in the direction of travel equal to the width of the stairway. Such dimension need not exceed 1.20m when the stairs has a straight run.

NATIONAL BUILDING CODE OF THE PHILI

Section 1207. Stairs, Exits, and OccupantLoads K: Exits shall be illuminated at any time thebuilding is occupied.

NATIONAL BUILDING CODE OF THE PHILI