Slide 1
THE NATIONALBUILDING CODE (CONDO)
DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. SANTOS, KITTTEMPLO, CHARMAINE Y.
CLASSIFICATION AND GENERAL REQUIREMENTS OF ALL BUILDINGSBY USE OR OCCUPANCY
USE OR OCCUPANCYUNIT AREA PER OCCUPANT(Sq. m.)Minimum of Two Exits other than elevators are required where number of occupant is over
A. Dwellings2810
B. Hotels18.610
Apartments18.610
Dormitories18.610
National Building Code of the Philippines
GROUP A RESIDENTIAL DWELLINGSSection 701
OCCUPANCY TYPE
GROUP B RESIDENTIAL, HOTEL, AND APARTMENTS
Section 702
No change shall be made in the character of occupancy of any building.
Section 703
One-storey building with more than one occupancy each portion shall conform to the requirement of each.
http://continuingeducation.construction.com/article.php
1.) One Hour Fire Resistive Operation
2.)Two Hour Fire resistive Operation
3.)Three Hour Fire ResistiveOperation
4.)Four Hour Fire Resistive Operation
TYPES OF OCCUPANCYSEPARATION
LOCATION ON PROPERTYNo buildings shall be constructed unless it adjoins a street
National Building Code of the PhilippinesLOCATION ON PROPERTY
LOCATION ON PROPERTY
LOCATION ON PROPERTY
MAXIMUM HEIGHT OFBUILDINGS
MAXIMUM HEIGHT OFBUILDINGS
MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY
MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY
National Building Code of the Philippines
MEASUREMENT ANDPERCENTAGE OF SITEOCCUPANCY
National Building Code of the Philippines
SETBACK REQUIREMENT
YARDType of Residential Use / Occupancy
R - 1(meters)R - 2R - 3R - 4(individual lot / unit meters)R - 5(meters)
Basic(meters)Maximum(meters)Basic(meters)Maximum(meters)
Front4.503.008.00*3.008.00*4.506.00
Side2.002.00**2.00*****2.00(optional)2.00(optional)3.00
Rear2.002.002.00***2.002.003.00
National Building Code of the Philippines
PARKING REQUIREMENT
3.60m * 12.00m bus/tracks
PARKING REQUIREMENT
PARKING REQUIREMENT
1.20 M
3.70 M
ELEVATOR
10.1 ACCESSIBLE ELEVATOR SHOULD BE LOCATED NOT MORE THAN 30.00 M FROM THE ENTRANCEAND SHOULD BE EASY TO LOCATE WITH THE AID OF SIGNS
10.2 ACCESSIBLE ELEVATORS SHALL HAVE A MINIMUM DIMENSION OF 1.10 M. x 1.4 M.
National Building Code of the Philippines
CEILING HEIGHTS
Min. 2.10 m
Min. 2.40 m
Min. 2.40 m
Min. 2.70m
National Building Code of the Philippines
CEILING HEIGHTS1st Floor w/ Natural VentilationMin. 2.70 m
MEZZANINE FLOORS
Min. 1.80 m.
Stairways 1
National Building Code of the Philippines
0.90 m
SIZE AND DIMENSIONSOF ROOMSMin.Area = 1.20 sq. m
National Building Code of the Philippines
PWD BATHROOM
30 M
KITCHEN
WINDOW OPENING
10 % FLOOR AREA
MIN. 3.00 M
ARCADEARCADE
BUILDING PROJECTION OVER PUBLIC STREETS
CORRIDORS
3.4 A MINIMUM CLEAR LEVEL SPACE OF 1.50 M X 1.50 M SHALL BE PROVIDED BEFORE EXTENDING BEYOND A DOOR;
EXCEPTION: WHERE A DOOR SHALL OPEN ONTO BUT NOT INTO A CORRIDOR, THE REQUIRED CLEAR, LEVEL SPACE ON THE CORRIDOR SIDE OF THE DOOR MAY BE A MINIMUM OF 1.20M CORRIDOR WIDTH
3.5) PROTECTION SHOULD BE PROVIDED FROM DOORS THAT SWING INTO CORRIDORS
RAMPS
1:12 RATIONational Building Code of the Philippines
STAIRWAYS
C
AB
National Building Code of the PhilippinesSTAIRLANDING
Min. 2.00m
max.3.60 m
Max. 1.20 m
HANDRAIL
3 m3 m
0.80 m < x > 0.90 m
EXITS
Total Width of Exits > total occupant load served / 165
OCCUPANT LOADNO. OF EXITS
Above first storey More than 102
500-9993
1000 or more4
Occupant load of morethan 10
EXIT 1EXIT 2
National Building Code of the Philippines
Exit 1Exit 2500 999 Occupant Load
EXIT DISTANCES EXIT< 1/5 EXIT
National Building Code of the Philipp
EXIT
National Building Code of the Philipp
10.7 lux
MIN OF 1.10 M
National Building Code of the Philipp
MIN OF 2 MHazardous Areas/ 50 ormore loadDOOR EXIT
NATIONAL BUILDING CODE OF THE PHILIPPINES(Mall)
DE GUZMAN, SUSHMITA SEN C. GUERRIN, GLADYS ANNE MEJIA, ELAND JETHRO PUZON, DANE STEFI MARIE P. SANTOS, KEITH L.TEMPLO, CHARMAINE Y.
Building Occupancy Group E:Business & Mercantile
National Building Code of the Philippine
Building TypeNumber of parking slotMarkets1 slot/150 sq.m. of shopping floor areaRestaurants, Fast-food centers,bars and beerhouses1 slot/30 sq.m. of customer areaOffice buildings1 slot/125 sq.m. of gross floor areaOther buildings in business/ commercial zones1 slot/125 sq.m. of gross floor areaPublic assembly buildings (theaters, cinemas, auditorium, stadium, etc.)1 slot/50 sq.m. of spectators areaBuilding Type (Recreational Facilities)Number of parking slotBowling Alleys1 slot/4 alleysAmusement center1 slot/50 sq.m. of gross floor areaPARKING REQUIREMENTS
PERPENDICULAR PARKING
5.00m2.40m
PARALLEL PARKING
2.00m6.00m
12.00m3.60m5.00m2.40m
Truck and Bus
Diagonal Parking
PARKING FOR PWD 1 accessible parking slot for the handicapped per 50 parking lots up to 150 slots and an additional slot for every 100 slots served.Maximum distance of accessible parking area from facility served. Parking areas for the physically handicapped shall be within 60.00m of the facility being
FACILITY SERVED
WALKWAY
PARKING SLOT
PARKING SLOT
PARKING SLOT
PARKING SLOT
PARKING SLOT
ONE WAY3.00mTWO WAY7.20m13.50m5.70m2.55m to 2.70m
90 DEG. PARKING BAY ONE SIDE
Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.
ONE WAY 3.00m
19.00m to 19.50m
TWO WAY7.20m
5.70m
2.55m to 2.70m
90 DEG. PARKINGBAY TWO SIDES
DABCXYZ9018.605.707.2018.605.707.206018.006.305.4016.655.655.404515.805.803.9013.854.973.90 Planning and Designers Handbook (Second Edition)
Max B. Fajardo Jr.
R = 17.00mto 21.00m
UP
4.00m toDN4.50m
4.00m to 4.50m
Planning and Designers Handbook (Second Edition)Max B. Fajardo Jr.
Bus
17.60m
2.10m
2.70m
7.60m
3.00m
Section 1207. Stairs, Exits, and Occupant Loads
C 1: Exit Door shall swing in the direction of travel. Double Acting Doors shall not be used as exits.
NATIONAL BUILDING CODE OF THE PHILIPINES
Section 1207. Stairs, Exits, and Occupant Loads C-3: Exit doorway shall be of a size as to permit the installation of a door not less than 900mm and not less than 2.00m in height
NATIONAL BUILDING CODE OF THE PHILIPINES
Section 1207. Stairs, Exits, and Occupant Loads C-5: Revolving, sliding, and overhead doors shall not be used as required exits.
Section 1207. Stairs, Exits, and Occupant Loads D-1: Every corridor or exit balcony shall not beless than 1.10 meters in width
NATIONAL BUILDING CODE OF THE PHILIPINES
Section 1207. Stairs, Exits, and OccupantLoads D-3: When more than one exit is required, they shallbe arranged to allow going to either direction fromany point in the corridor.
Section 1207. Stairs, Exits, and OccupantLoads Corridors and exterior exit balconies with dead endsare permitted when the dead end does not exceed6.00 meters in length
NATIONAL BUILDING CODE OF THE PHILI
Section 1207. Stairs, Exits, and OccupantLoads E-1: Stairway widths Occupant Load (X) = Minimum WidthX > 50= 1100MMX < 50= 900MMX < 10= 750MM
ore than 100MMTrim and handrails shall not reduce the required width by m
Section 1207. Stairs, Exits, and OccupantLoads E-3: Winding stairways may be used if the requiredwidth of the run is provided at a point not more than 300MM from the side where the treads are
narrower.NATIONAL BUILDING CODE OF THE PHILI
Section 1207. Stairs, Exits, and OccupantLoads E-5: Every landing shall be a dimension measured in the direction of travel equal to the width of the stairway. Such dimension need not exceed 1.20m when the stairs has a straight run.
NATIONAL BUILDING CODE OF THE PHILI
Section 1207. Stairs, Exits, and OccupantLoads K: Exits shall be illuminated at any time thebuilding is occupied.
NATIONAL BUILDING CODE OF THE PHILI