Top Banner
R ESID E When technology meets comfort RESIDENTIAL STYLE AIR CONDITIONING SYSTEMS 154322_Residential_brochure_06.i1 1 154322_Residential_brochure_06.i1 1 14-02-2007 12:29:12 14-02-2007 12:29:12
44

154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Jun 05, 2020

Download

Documents

dariahiddleston
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

RESIDEWhen technology meets comfortRESIDENTIAL STYLE AIR CONDITIONING SYSTEMS

154322_Residential_brochure_06.i1 1154322_Residential_brochure_06.i1 1 14-02-2007 12:29:1214-02-2007 12:29:12

Page 2: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

154322_Residential_brochure_06.i2 2154322_Residential_brochure_06.i2 2 14-02-2007 12:29:2014-02-2007 12:29:20

Page 3: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

IndexContents2007 Residential Product Line

The inverter company page 06

Indoor Air Quality page 12

Care for users page 18

Matching table page 22

Daiseikai page 24

GKV page 26

Ducted inverter page 28

Fixed-speed high-wall page 30

Fixed-speed Flexi page 32

Outdoor multi-splits page 34

Combination ratings page 36

154322_Residential_brochure_06.i3 3154322_Residential_brochure_06.i3 3 14-02-2007 12:29:2214-02-2007 12:29:22

Page 4: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Innovative technologies, ingenioToshiba raises the standard!

Innovative technologies, ingenious characteristicsToshiba raises the standard!Toshiba’s philosophy and slogan is “Committed to people, committed to the future”.

This is represented strongly in the residential systems, where attention to the needs of each and every individual is paramount and Toshiba recognise and respect their desire for improved well-being.

Thanks to Toshiba’s continuous dedication, research and development, only the most modern technologies are applied to their systems.

Toshiba’s objective is continuous innovation, constantly reaching out to reduce the impact on the environment and increase our personal comfort and well-being.

DC Hybrid InverterTechnology.

DC Hybrid InverterTechnology.It’s true: Toshiba was the first air conditioning manufacturer to utilise inverter technology within air conditioning systems in 1981. Being first to develop and utilise innovative technology is a passion for Toshiba.

Inverter technology immediately demonstrated its advantages: precisely matching the cooling

or heating requirement, energy efficiency, and guaranteeing accurate temperature control.The development of the new and exclusive DC Hybrid Inverter has again confirmed this innovative capability and leadership position in technology in fast and growing and air conditioning market.

Cu

4

ResTI

154322_Residential_brochure_06.i4 4154322_Residential_brochure_06.i4 4 14-02-2007 12:29:2414-02-2007 12:29:24

Page 5: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

o

Care forusers.

Care forusers.The benefits of Toshiba’s refined designs include flexibility in application, low operating sound levels, improved indoor air quality and all-around comfort. This comfort is a result of precise temperature control thanks to the inverter technology. The inverter ensures that the required temperature of the occupant is reached quickly and maintained stable – eliminating temperature fluctuations often experienced with non-inverter systems.

5

sidentialA step beyond well-being

The mission? Improved Indoor Air Quality.

The mission? Improved Indoor Air Quality.Comfort in the home means much more than just controlling the temperature. Because of this, Toshiba is the best investment for the enhanced well-being of the family environment.

One of Toshiba’s research objectives is the continuous introduction of new ways to eliminate air pollutants n the residential air conditioning sector. From the first and most advanced system of air purification, named

Daiseikai, to the most imaginative use of natural materials, such as extracts of Sasa and Gingko – Toshiba really do put the occupants health and well-being first.

154322_Residential_brochure_06.i5 5154322_Residential_brochure_06.i5 5 14-02-2007 12:29:3114-02-2007 12:29:31

Page 6: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

154322_Residential_brochure_06.i6 6154322_Residential_brochure_06.i6 6 14-02-2007 12:29:3614-02-2007 12:29:36

Page 7: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

7

InverThe Inverter CompanyMuch more than an inverter

154322_Residential_brochure_06.i7 7154322_Residential_brochure_06.i7 7 14-02-2007 12:29:4214-02-2007 12:29:42

Page 8: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

SerialPort

FlashROM

I/O DSPCPU

ADC

PWM GateDrivers

3 phaseinverter PMSM

Resistivedivider

DC_DC EMIfilter

+15V+5V ac line

GND

V bus

I bus+

-

Dash DSP

T

T

8

Toshiba: the inverter company.

Control electronics.Control electronics.

Toshiba’s deep understanding of the functional characteristics of inverters has allowed it to refine the idea of energy savings along with continuous improvements in key areas, such as the power factor.

Power FactorThe power factor of an electrical load, such as a motor, is its power output compared to the energy it consumes, both measured in watts. Ideally, the electrical current and voltage are “in phase”, and the power factor is 100%.

Actual operating conditions cause an inverter system to deviate from this ideal. Under a high load, the continuous alternative of wave peaks, the switching PAM is the best control method because the power factor reaches 99%.

With a reduced load however, the PAM control method due to its switching results in significant energy losses. For this situation, the “PWM” control method yields higher efficiency and reduced energy consumption.

Most inverter air conditioners use one or the other of these control methods. Only Toshiba has combined the two technologies, creating the “DC Hybrid Inverter”, that chooses automatically the better of the two control methods based on the actual conditions at the time.This solution provides high capacity when it is necessary. For very cold winter days or hot summer days use the PAM method, and for very low energy consumption when conditions are less severe use the PWM method. Given that maximum capacity is

DC HYBRID INVERTER

Toshiba: the inverter company.The efficiency of an inverter air conditioner is determined by the efficiency of each component it contains: the control electronics, the motor, and the compressor. Toshiba has focused its attention on all of these components.

154322_Residential_brochure_06.i8 8154322_Residential_brochure_06.i8 8 14-02-2007 12:29:4314-02-2007 12:29:43

Page 9: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

The driver of technology.

The twin rotary compressor.The twin rotary compressor.

The driver of technology.

permanent magnets allows the best synchronisation with the frequency of the voltage applied by the control circuit. The rpm is therefore precisely selected to match the ambient conditions.

9

The motor that drives the revolutions of the air conditioner is a concentration of mechanical technology and electromagnetic engineering. The most advanced methods of modelling were used to determine the best configuration of the permanent magnets of the DC motor. A perfect choice for the shape and materials for the

The compressor is the third extra-thermodynamic element in which Toshiba has continuously improved, finally arriving at the solution called the DC Twin Rotary Compressor. It is a double cam rotary compressor having several features that increase its performance and reliability. The opposed, double blade design yields mechanical stability and less vibration that could cause stress on other components. In fact, being able to reduce the rpm without causing instability enables

improved temperature control when less capacity is required. An added benefit offered by the DC Twin Rotary Compressor is its low noise level compared to normal rotary compressors, and with refrigerant R410A, it is more efficient than scroll compressors.

not often required, and that high efficiency is always desirable, the result is a greatly reduced annual energy consumption.

Shape of the supply wave Features Capacity needed

Low

Medium

HighFor example:1 – at start

2- severe temperature

Inverter control

Automatic change

PWM

325V

325V

360V

325V

360V

PAM

PWM

PAM

Shape of the supply wave

Supply voltage maintained at 325 volts.

The supply voltage is increased automaticallyto 360 volts to increase the capacity supplied Network voltage: 230V

High efficiency

High power

154322_Residential_brochure_06.i9 9154322_Residential_brochure_06.i9 9 14-02-2007 12:29:4614-02-2007 12:29:46

Page 10: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

The efficiency exceeds the energy classification.

10

The efficiency exceeds the energy classification.Toshiba air conditioners offer an advantage that can be quantified exactly, which is more than simply meeting an energy classification, these give energy efficiencies at nominal application conditions. But an air conditioner should be efficient all day, every day of the year. Toshiba inverter air conditioners can save up to 50% on energy costs throughout the year.

TOSHIBA offers the widest range of residential products having the highest possible energy classification “A”.

154322_Residential_brochure_06.i10 10154322_Residential_brochure_06.i10 10 14-02-2007 12:29:4814-02-2007 12:29:48

Page 11: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Technology in multi-split systems.

Technology in multi-split systems.When it is necessary to air condition more than just one room, the line-up of Toshiba’s multi-split systems is the perfect solution for every requirement.

One outdoor unit is capable of operating 2, 3 or 4 indoor units of your choice, all indoor styles are designed to compliment any interior. The multi-split systems have several capacity steps and electronic capacity control that ensure user comfort and ease of control.

Toshiba Multisplit systems offer a wide range of possibilities to create all the comfort you desire. The full range of internal units satisfies every requirement, including ducted ceiling units and high wall models that incorporate advanced filtration and air cleaning characteristics to improve indoor air quality.

11

Huge energy savings

Precision capacity control

Maximum environmental compatibility

Compact and modern design

154322_Residential_brochure_06.i11 11154322_Residential_brochure_06.i11 11 14-02-2007 12:29:5414-02-2007 12:29:54

Page 12: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

154322_Residential_brochure_06.i12 12154322_Residential_brochure_06.i12 12 14-02-2007 12:30:0214-02-2007 12:30:02

Page 13: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

13

IAQThe mission? Improved Indoor Air Quality

154322_Residential_brochure_06.i13 13154322_Residential_brochure_06.i13 13 14-02-2007 12:30:0514-02-2007 12:30:05

Page 14: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

14

Air cleaning.Air cleaning.

Up to 99% air cleaning efficiencyToshiba was first to introduce an air conditioner with a true two-stage, double function air purification and deodorising filter. Its electrostatic cell can remove more than 99% of the pollutants, purifying (eliminating allergens, dust, smoke, bacteria, viruses, mould and dust mites) and deodorising for the elimination of every odour molecule.

(*) Efficiency of the electrostatic cell as measured by the trapping of PM10 with an applied voltage of 4.2 and 2.7 kV and an airflow of 85 m3/h

The secret of air purificationElectrostatic precipitation for air cleaning consists of three basic steps.

• Applying an electrical charge to particles suspended in the air;• Capturing the particles;• Removal of the captured particles.

The charging is effected by means of an ionising mechanism for discharging using the corona effect, obtained in the presence of an electrical field strongly non-uniform. The electrons highly accelerated by the electric field cause the ionisation of the gas that makes

Taup the surrounding air. The ions

produced collide with the suspended particles and transfer their electrical charge. Each charged particle is attracted to the collector, where it is captured. Periodically the particles on the collector are cleaned from it by the action of a liquid detergent.

154322_Residential_brochure_06.i14 14154322_Residential_brochure_06.i14 14 14-02-2007 14:08:5914-02-2007 14:08:59

Page 15: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

15

The Toshiba application and the state-of-the-art Daiseika

The Toshiba application and the state-of-the-art Daiseikai.

The characteristics of the plasma air purifier yield a greater than 90% performance measured on granulometry, they are also very compact, along with a very low pressure drop. The plasma purifier, in combination with zeolite filters can eliminate particles as small as 0.0001 micron. Its operating life is long with little maintenance required, and no moving parts, which increases its reliability. The Daiseikai air purifier is “bi-voltage” (Penney configuration) consisting of an ionisation particle barrier followed by a high voltage particle collector. This offers

advantages with respect to the single voltage type, with the non-electrically charged collector -affording more surface capture area and a higher efficiency in a smaller space. The Toshiba air purifier has a larger capture area in the air flow than any other high wall unit filter, offering unbeatable efficiency.

Purification and deodorising

Removal of every type of pollutant

Air purification ten times faster than standard filters

The greatest filter surface without pressure drop

Infinite lifetime

154322_Residential_brochure_06.i15 15154322_Residential_brochure_06.i15 15 14-02-2007 12:30:0914-02-2007 12:30:09

Page 16: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

16

Ionisation.When technology learns from n

Ionisation.When technology learns from nature.The theory

Studies have shown that small, light ions, formed from atmospheric gases, generated from cosmic rays or from ultraviolet radiation, are characterised by a high mobility, and occur predominantly in open and uncontaminated spaces. Heavy ions, instead, formed from the agglomeration of many small ions on the surface of aerosol spray droplets or from solid particles, and typically are abundant in industrial and heavily populated zones. Experimental data exists showing a correlation between the electric conditions of the atmosphere and the health of the people living in it.

The practice

Ideal conditions for well-being are a concentration of about 2000 small ions per cm3 of air (typical of a forest). The ionic condition of the air in closed ambients is quite different from the ideal: in fact, in a closed area the sources of positive ionisation predominate, while indoor pollution with both organic and inorganic origins causes the formation of large ions at the expense of the small ones. Emitting only anions has a deleterious effect: the suspended particles are first neutralised, and then negatively charged, therefore causing their precipitation on surfaces in the ambient. To overcome this problem it is absolutely necessary to combine an ioniser with a good filtration system.

Toshiba advantages

Daiseikai can produce up to 35,000 negative ions per cm3 of air, with an average of 10,000 per cm3. This value is equivalent to the quality of air near a waterfall, and is better than the forest. This emission of negative ions offsets the excess of positive ions generally present in homes and reaches the concentration levels that are found in the cleanest zones of the planet.

(*) Measurement is performed with ambient conditions of 24°C and a relative humidity of 80%. When functioning in the “dry” mode, 35,000 ions per cm3 were measured in a test room of 17 square metres, at a height of one metre above the floor and after two hours of operation, the room temperature was 24°C and humidity 50%.

Toshiba ionisationStandard indoor situationIons in the atmosphere

Na

154322_Residential_brochure_06.i16 16154322_Residential_brochure_06.i16 16 14-02-2007 14:11:5914-02-2007 14:11:59

Page 17: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

17

nNothing escapesa Toshiba filter!

Nothing escapesa Toshiba filter!Catechina

The new catechina pre-filter from Toshiba (available on the Daiseikai models) introduces a further method of purifying the air.

This further treatment improves the cleanliness of the air from the time it enters the air conditioner. The catechina has three effects: deodorant, anti-bacteria, and fungus removal. In particular, because the treatment occurs on the pre-filter, the anti-mould property is increased. The filter is covered with a layer of catechina, a strong antioxidant that helps to neutralise free radicals and prevents the effects of oxidation in the organism.

Sasa Zeolite Plus

Toshiba’s advanced technology provides you with an exclusive “SASA-ZEOLITE PLUS FILTER” which is a combination of a Sasa (bamboo extract) and Zeolite-plus filter. The bamboo extract has bacteria1 and virus2 deactivation properties. Meanwhile, Zeolite-plus filter traps odors, removes chemicals and cleans pollutants from the air. The filter is easy to maintain by simply washing with soapy water and rinsing with clean water. Drying it in sunlight for 3-6 hours will regenerate the filter.

1 Test under Japanese Industrial Standard (JIS) Z2801 at the Japan Food Research Laboratories2 Type A influenza virus, tested at the Japan Food Research Laboratories

Bio-Enzyme Gingko

TOSHIBA’s new “BIO-ENZYME & GINGKO FILTER” is a combination of Bio-enzyme and Gingko leaf extract. Bio-enzyme will eliminate bacteria1, virus and mold2. Meanwhile the Gingko extract reduces agents that can cause allergic reactions3.

The Gingko leaf extract consists of many kinds of flavanoids and gingkoloyde which have many physiological activities and are used in some health foods.

1 Bacteria type : Escherichia Coli, Staphylococcus Aureus (tested under JIS Z2801:2000 standard, test report no.103072045-004 by the Japan Food Research Laboratories)2 Mold type : Aspergillus Niger, Penicillium Citrinum, Chaetomium Globosum, Myrothecium Verrucaria (tested under JIS Z2911:2000, test report no. 103072045-005 by the Japan Food Research Laboratories)3 Test allergen :Cedar pollen allergen, Tick allergen (at Hoshi Unversity)

Catechina Sasa-Zeolite Plus Bio-Enzyme Gingko

154322_Residential_brochure_06.i17 17154322_Residential_brochure_06.i17 17 14-02-2007 14:12:0814-02-2007 14:12:08

Page 18: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

154322_Residential_brochure_06.i18 18154322_Residential_brochure_06.i18 18 14-02-2007 12:30:3014-02-2007 12:30:30

Page 19: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

19

CareCare for your well-beingToshiba comfort all year round

154322_Residential_brochure_06.i19 19154322_Residential_brochure_06.i19 19 14-02-2007 12:30:3214-02-2007 12:30:32

Page 20: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Automatic changeover.

20

The unmistakablesound of silence.

The unmistakablesound of silence.Powerful AirflowTo provide a faster response to the demand for quick cool down, the Hi-Power mode delivers the highest air flow (up to 650 m3/h) of cool air. At both low and high speed the system emits very low sound levels, whilst meeting your comfort needs quickly and efficiently.

Super Quiet & Maximum ComfortBy pressing the “Quiet” button on the remote control, the fan shifts to the super low speed, reducing the sound of the indoor unit by 3 dB(A), to only 22 dB(A).

Comfort sleepThe temperature during the night is normally cooler than during the day. By pressing the “Comfort Sleep” button (in cooling mode) the room temperature will be allowed to rise by one degree per hour for two or three hours, providing you with the ultimate comfort whilst asleep.

Self Cleaning FunctionToshiba’s new Self-Cleaning Function is designed to reduce the humidity that causes mould to form inside the air conditioner. This advanced and efficient system reduces moisture on the coil. When the air conditioner is turned off, the internal fan continues to run for 20 minutes, drying the moisture on the coil, it then turns off automatically.

12 Step Selectable LouvreThe Toshiba new series is designed with 12 louvre positions to ensure a more efficient and flexible airflow. The louvre design has also been improved for more efficient and quieter air distribution.

A new appearancefor technology.

A new appearancefor technology.Toshiba always pays attention to aesthetics, letting the design suggest to you what’s inside; now modern technology and quality have a new appearance. The new Daiseikai unit, with soft and refined lines and a smooth front panel with an

elegant cobalt blue insert, projects its personality: purity and power.

The flexi unit, installed on the floor or suspended from a ceiling, is easily recognised; its elegant profile fits harmoniously in all situations.

Automatic changeover.Another Toshiba first is the automatic changeover on many models. The highest comfort levels are ensured both with the automatic changeover between heating and cooling and the automatic alternating between cooling and dehumidification.

22dB(A)

154322_Residential_brochure_06.i20 20154322_Residential_brochure_06.i20 20 14-02-2007 12:30:3314-02-2007 12:30:33

Page 21: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

er.

21

ToshibaRemote Con

ToshibaRemote Controls.One-touch presetThe one-touch Preset memory allows the user to store their preferred comfort settings, and restore all of them at the simple touch of a button.

One-touch auto modePress the auto button to set they system in to fully automatic mode. Your air conditioner will automatically choose the best settings to achieve your desired temperature quickly and maintain it stable.

Five selectable fan speeds plus AutoChoose your desired airflow from the five fan speeds or select the Auto Fan Speed mode and let the air-conditioner select it for you.

Operating ModesSelect the Operating Mode: Cooling, Dry Mode (Dehumidification), Fan only, Heating (only for heat pump model) or Auto Change over.

Quiet ModeBy pressing the “Quiet” button on the remote control, the indoor unit will only operate at super low fan speed.

Auto swing or fixed louver positionSelect your preferred airflow distribution: “Fix” to choose any one of the 12 louver positions that you prefer or “Swing”, this moves smoothly between all positions for a comfortable air flow.

Real Time - On/Off Timer - Repeat TimerThe real time On/Off timer provides easy-to-set on and off operating times. The repeat timer allows for automatic repetition of the timer settings every 24 hours.

Auto DiagnosisThe unit is equipped with a 36 Code Auto Diagnosis system that constantly monitors all the main functions and components of the system to enable maintenance scheduling.

Eco-logicThe Eco-logic mode achieves energy savings of up to 25% compared to the standard operation mode, whilst improving your comfort by automatically increasing the temperature setting.

Hi-PowerSelect “Hi-Power” for extra airflow, that will cool you down much faster than standard operation.

01

02

03

04

05

06

07

08

09

10

Suitable for:

Daiseikai

Suitable for:

GKV high-wallGKP Fixed-speed high-wallGFP Fixed-speed Flexi

154322_Residential_brochure_06.i21 21154322_Residential_brochure_06.i21 21 14-02-2007 12:30:3814-02-2007 12:30:38

Page 22: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

22

Residential range - Monosplit - Matching table

SizesCapacity

072.2 kW

102.7 kW

133.6 kW

164.5 kW

185.0 kW

246.3 kW

Daiseikai

FIX

ED

SP

EE

D

Indoor Units

INV

ER

TER

Outdoor Units

Line Extension

Length

Hei

ght

RAS 07GA-ES2RAS 07GKP-ES2

RAS10GA-ES2RAS 10GKP-ES2

RAS 10GAH-ES2RAS 10GKHP-ES2

RAS 13GA-ES2RAS13GKP-ES2

RAS 13GAH-ES2RAS 13GKHP-ES2

RAS 10GAVP-E

RAS B10GKVP-E

RAS 13GAVP-E

RAS B13GKVP-E

RAS 10GAV-E2

RAS 10GKV-E2

RAS 13GAV-E2

RAS 13GKV-E2

RAS 16GAVP-E

RAS B16GKVP-E

RAS 16GAV-E2

RAS 16GKV-E2

RAS 18GA-ES2RAS 18GKP-ES2

RAS 18UAH-ES2RAS 18UKHP-ES2

RAS 24GA-ES2RAS 24GKP-ES2

RAS 24GAH-ES2RAS 24GKHP-ES2

RAS 18GA-ES2RAS 18GFP-ES2

RAS 18GAH-ES2RAS 18GFHP-ES2

RAS 24GA-ES2RAS 24GFP-ES2

RAS 24GAH-ES2RAS 24GFHP-ES2

GKV

GK

GF

GK Small Chassis

154322_Residential_brochure_06.i22 22154322_Residential_brochure_06.i22 22 14-02-2007 12:30:4014-02-2007 12:30:40

Page 23: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

23

Residential range - Multisplit - Matching table

Outdoor Units

14 18 26 23 27

2 ROOMS 3 ROOMS 4 ROOMS

HP CO HP CO HP CO HP CO

Sizes

HP

RAS B10GKVP-E

RAS B13GKVP-E

RAS B16GKVP-E

CO

RAS M10GKCVP-E

RAS M13GKCVP-E

RAS M16GKCVP-E

HP

RAS M10GKV-E

RAS M13GKV-E

RAS M16GKV-E

CO

RAS M10GKCV-E

RAS M13GKCV-E

RAS M16GKCV-E

HP

RAS M10GDV-E

RAS M13GDV-E

RAS M16GDV-E

CO

RAS M10GDCV-E

RAS M13GDCV-E

RAS M16GDCV-E

Daiseikai GKV Ducted

Complete matching availability on pages 36 to 41

Available indoor units

154322_Residential_brochure_06.i23 23154322_Residential_brochure_06.i23 23 14-02-2007 12:30:4414-02-2007 12:30:44

Page 24: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Residential

24

Daiseikairesidential high-wall .

RATED EER: 4.55

DC HYBRID INVERTER

SINGLE/MULTI-SPLIT

R410A

Plasma air purifi er

Catechin pre-filter

Self-cleaning function

Zeolite Plus Filter

Air ioniser

Daiseikaihigh-wall residential.Features

The 3-in-1 Daiseikai High-wall unit is not only one of the best Air Conditioners on the market, it is also an Air Purifier and Ioniser.Toshiba is proud to introduce the latest version of the Daiseikai range, now also available as a multi-split system. With its enhanced design, exceptional EER levels and superior air quality features, Daiseikai launches a new era in air conditioning.

Key features

Purifying and Deodorizing: New triple-action filtering system - Catechin anti-mould and virus deactivation filter, Zeolite Plus filter and Plasma filter - to improve the indoor air quality in your home.

Relaxing: Air ioniser for optimum user comfort and enhanced well-being.

Superior EER: up to 4.55 in cooling mode (size 10), for lowest energy consumption and highest savings.

Optimum air flow distribution: 12 fixed louvre positions + auto swing mode and auto positioning.

Easy installation: any piping connection direction at the rear of the unit and easy wiring at the front of the unit.

Self-cleaning function.

154322_Residential_brochure_06.i24 24154322_Residential_brochure_06.i24 24 14-02-2007 12:30:4814-02-2007 12:30:48

Page 25: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

25

* Also available in Multi-split (Cooling only and Heat pump) - see Matching table pages 22-23

Technical specifications heat pump

heat pump cooling onlyIndoor units

Single-split Outdoor units

B10GKVP-E

10GAVP-E

B13GKVP-E

13GAVP-E

B16GKVP-E

16GAVP-E

-

-

-

-

-

-

Indoor units

Multi-split Outdoor units (2 rooms)

(2 rooms)

(3 rooms)

(4 rooms)

B10GKVP-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

B13GKVP-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

B16GKVP-E

-

M18GAV-E

3M26GAV-E

4M27GAV-E

M10GKCVP-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M13GKCVP-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M16GKCVP-E

-

M18GACV-E

3M23GACV-E

4M27GACV-E

Outdoor unit

Indoor unit*

RAS-10GAVP-E

RAS-B10GKVP-E

RAS-13GAVP-E

RAS-B13GKVP-E

RAS-16GAVP-E

RAS-B16GKVP-E

Cooling capacity kW CO 2.5 3.5 4.5

Cooling range (min. - max.) kW CO 0.5 - 3.5 0.6 - 4.5 0.8 - 5.0

Power input (min - rated - max.) kW CO 0.10 - 0.55 - 0.86 0.11 - 0.92 - 1.36 0.15 - 1.38 - 1.82

EER W/W CO 4.55 3.80 3.26

Energy effi ciency class CO A A A

Annual energy consumption kWh CO 275 460 690

Heating capacity kW HP 3.2 4.2 5.5

Heating range (min. - max.) kW HP 0.6 - 5.8 0.6 - 6.6 0.8 - 7.8

Power input (min - rated - max.) kW HP 0.12 - 0.71 - 1.72 0.12 - 0.98 - 1.89 0.15 -1.51 - 2.48

COP W/W HP 4.51 4.31 3.64

Energy effi ciency class HP A A A

Indoor unit* RAS-B10GKVP-E RAS-B13GKVP-E RAS-B16GKVP-E

Air fl ow (h/l) m3/h - l/s CO 546/276 - 152/77 564/276 - 157/77 606/318 - 168/88

Sound pressure level (h/l) dB(A) CO 42/27 43/27 45/29

Sound power level (h/l) dB(A) CO 55/40 56/40 58/42

Air fl ow (h/l) m3/h - l/s HP 612/282 - 170/78 636/300 - 177/83 678/342 - 188/95

Sound pressure level (h/l) dB(A) HP 43/27 44/27 45/29

Sound power level (h/l) dB(A) HP 56/40 57/40 58/43

Dimensions (HxWxD) mm 250 x 790 x 215 250 x 790 x 215 250 x 790 x 215

Weight kg 9 9 9

Outdoor unit RAS-10GAVP-E RAS-13GAVP-E RAS-16GAVP-E

Air fl ow m3/h - l/s 2148 -597 2406 - 669 2406 - 669

Sound pressure level dB(A) CO 46 48 49

Sound power level dB(A) CO 59 61 62

Operating range °C CO 5 - 43°C 5 - 43°C 5 - 43°C

Sound pressure level dB(A) HP 47 50 50

Sound power level dB(A) HP 60 63 63

Operating range °C HP -15 - 24°C -15 - 24°C -15 - 24°C

Dimensions (HxWxD) mm 550 x 780 x 290 550 x 780 x 290 550 x 780 x 290

Weight kg 35 37 37

Compressor type DC Twin rotary DC Twin rotary DC Twin rotary

Flare connections

Gas in 3/8 3/8 1/2

Liquid in 1/4 1/4 1/4

Minimum pipe length m 2 2 2

Maximum pipe length m 25 25 25

Maximum height difference m 10 10 10

Chargeless pipe lenght m 15 15 15

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

154322_Residential_brochure_06.i25 25154322_Residential_brochure_06.i25 25 14-02-2007 12:30:5014-02-2007 12:30:50

Page 26: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

26

GKVresidential high-wall.

R410A

DC HYBRID INVERTER

SLIM-LINE HIGH-WALL

SINGLE/MULTI SPLIT

Zeolite + Sasa fi lters

Byo-Enzyme + Gingko fi lters

One touch pre-set memory

Hi power

GKVhigh-wall residential.Features

Innovative technology, ingenious features and attractive design - Toshiba’s GKV raises the standard of air conditioning yet again with a new level of comfort.Comfort comes with the whisper-quiet operation and optimum airflow management system, whilst the new filtration system ensures you only breathe a pure air.The units are available as single or multi-split systems, with the multi-split system offering the increased flexibility of one outdoor unit serving up to four indoor units.

Key features

New enhanced aesthetic and slimline design.

New enhanced fi ltration system:Zeolite Plus + Sasa fi lter to deodorise, Bio-Enzyme fi lter + Gynko fi lter to purify and new anti-oxidant Vitamin C fi lter.

Latest Digital hybrid inverter technology for increased energy efficiency, optimised comfort and superior reliability.

One touch pre-set memory: to recall your favourite settings.

Low noise level: it operates at only 29dB(A) in cooling only mode (size 10) for comfortable nights.

Hi-power: lowers/raises temperature and increases fan speed to get the desired temperature faster.

154322_Residential_brochure_06.i26 26154322_Residential_brochure_06.i26 26 14-02-2007 12:30:5114-02-2007 12:30:51

Page 27: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

27

* Also available in Multi-split (Cooling only and Heat pump) - see Matching table pages 22-23

Technical specifications heat pumpOutoor unit RAS-10GAV-E2 RAS-13GAV-E2 RAS-16GAV-E2

Indoor unit* RAS-10GKV-E2 RAS-13GKV-E2 RAS-16GKV-E2

Cooling capacity kW CO 2.5 3.5 4.62

Cooling range (min. - max.) kW CO 0.9 - 3.0 1.1 - 4.0 1.2 - 5.2

Power input (min - rated - max.) kW CO 0.26 - 0.76 - 0.97 0.19 - 1.07 - 1.30 0.25 - 1.62 - 1.90

EER W/W CO 3.29 3.27 2.85

Energy effi ciency class CO A A C

Annual energy consumption kWh CO 380 535 810

Heating capacity kW HP 3.2 4.2 5.9

Heating range (min.-max.) kW HP 0.9 - 4.0 1.1 - 5.8 1.3 - 7.4

Power input (min - rated - max.) kW HP 0.20 - 0.84 - 1.12 0.19 - 1.13 - 1.64 0.26 - 1.73 - 2.32

COP W/W HP 3.81 3.72 3.41

Energy effi ciency class HP A A B

Indoor unit* RAS-10GKV-E2 RAS-13GKV-E2 RAS-16GKV-E2

Air fl ow (h/l) m3/h - l/s CO 528/342 - 147/95 528/342 - 147/95 762/522 - 212/145

Sound pressure level (h/l) dB(A) CO 38/27 39/26 45/34

Sound power level (h/l) dB(A) CO 51/40 52/39 58/47

Air fl ow (h/l) m3/h - l/s HP 618/408 - 172/114 618/408 - 172/114 780/570 - 217/160

Sound pressure level (h/l) dB(A) HP 39/29 39/28 44/34

Sound power level (h/l) dB(A) HP 52/42 52/41 57/47

Dimensions (HxWxD) mm 275 x 790 x 218 275 x 790 x 218 275 x 790 x 218

Weight kg 10 10 10

Outdoor unit RAS-10GAV-E2 RAS-13GAV-E2 RAS-16GAV-E2

Air fl ow m3/h - l/s 2405 - 673 2405 - 673 2405 - 673

Sound pressure level dB(A) CO 46 48 51

Sound power level dB(A) CO 59 61 64

Operating range °C CO 15 - 43°C 15 - 43°C 15 - 43°C

Sound pressure level dB(A) HP 47 50 53

Sound power level dB(A) HP 60 63 66

Operating range °C HP -10 - 24°C -10 - 24°C -10 - 24°C

Dimensions (HxWxD) mm 530 x 660 x 240 550 x 780 x 270 550 x 780 x 270

Weight kg 30 36 39

Compressor type DC Inverter DC Inverter DC Inverter

Flare connections

Gas in 3/8 3/8 1/2

Liquid in 1/4 1/4 1/4

Maximum pipe length m 10 15 15

Maximum height difference m 8 10 10

Pre-charged pipe length m 10 15 15

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

heat pump cooling onlyIndoor units

Single-split Outdoor units

10GKV-E

10GAV-E

13GKV-E

13GAV-E

16GKV-E

16GAV-E

-

-

-

-

-

-

Indoor units

Multi-split Outdoor units (2 rooms)

(2 rooms)

(3 rooms)

(4 rooms)

M10GKV-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

M13GKV-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

M16GKV-E

-

M18GAV-E

3M26GAV-E

4M27GAV-E

M10GKCV-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M13GKCV-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M16GKCV-E

-

M18GACV-E

3M23GACV-E

4M27GACV-E

154322_Residential_brochure_06.i27 27154322_Residential_brochure_06.i27 27 14-02-2007 12:30:5314-02-2007 12:30:53

Page 28: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Residential

28

R410A

DC HYBRID INVERTER

DUCTED MULTI-SPLIT

IR REMOTE CONTROL

Only 230 mm high

Flexible air return

High static pressure

Residentialducted inverter.

Residentialducted inverter.Features

The ducted Multi-split inverter units offer reliable, controllable comfort all year round. The extremely compact and quiet units are suitable for a wide range of residential and light commercial applications, with one outdoor unit serving up to four indoor units.

Key features

Easy-to-use infrared remote control or wired remote control as an option.

Low noise level: at the low fan speed mode, the unit operates at only 23dB(A).

Very slim design: only 230 mm in height, for easier and more flexible installation.

Flexible air inlet: rear or below the unit.

Drain pump kit available as an option.

Up to 63.7 Pa static pressure.

154322_Residential_brochure_06.i28 28154322_Residential_brochure_06.i28 28 14-02-2007 12:30:5414-02-2007 12:30:54

Page 29: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

29

* Only available in Multi-split (Cooling only and Heat pump) - see Matching table pages 22-23** static pressure at nominal condition

Technical specifications cooling only

Technical specifications heat pump

Indoor units

Single-split Outdoor units

-

-

-

-

-

-

-

-

-

-

-

-

Indoor units

Multi-split Outdoor units (2 rooms)

(2 rooms)

(3 rooms)

(4 rooms)

M10GDV-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

M13GDV-E

M14GAV-E

M18GAV-E

3M26GAV-E

4M27GAV-E

M16GDV-E

-

M18GAV-E

3M26GAV-E

4M27GAV-E

M10GDCV-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M13GDCV-E

M14GACV-E

M18GACV-E

3M23GACV-E

4M27GACV-E

M16GDCV-E

-

M18GACV-E

3M23GACV-E

4M27GACV-E

heat pump cooling only

Indoor unit* RAS-M10GDCV-E RAS-M13GDCV-E RAS-M16GDCV-E

Cooling capacity kW CO 2.7 3.7 4.5

Indoor unit* RAS-M10GDV-E RAS-M13GDV-E RAS-M16GDV-E

Cooling capacity kW CO 2.7 3.7 4.5

Heating capacity kW HP 4.0 5.0 5.5

Indoor unit* CO RAS-M10GDCV-E RAS-M13GDCV-E RAS-M16GDCV-E

HP RAS-M10GDV-E RAS-M13GDV-E RAS-M16GDV-E

Air fl ow (h/l) m3/h - l/s CO 720/400 - 200/111 780/428 - 217/119 780/428 - 217/119

Sound pressure level (h/l) dB(A) CO 31/23 32/24 33/25

Sound power level (h/l) dB(A) CO 44/36 45/37 46/38

Operating range °C CO 21 - 32°C 21 - 32°C 21 - 32°C

Air fl ow (h/l) m3/h - l/s HP 720/450 -200/111 780/428 - 217/119 780/428 - 217/119

Sound pressure level (h/l) dB(A) HP 32/24 33/25 34/26

Sound power level (h/l) dB(A) HP 45/37 46/33 47/34

Operating range °C HP 0 - 28°C 0 - 28°C 0 - 28°C

Dimensions (HxWxD) mm 230 x 750 x 440 230 x 750 x 440 230 x 750 x 440

Weight kg 19 19 19

Flare connections

Gas in 3/8 3/8 1/2

Liquid in 1/4 1/4 1/4

External static pressure**

(stand/upper limit)

Pa 35.3/54.9 41.2/63.7 41.2/63.7

154322_Residential_brochure_06.i29 29154322_Residential_brochure_06.i29 29 14-02-2007 12:30:5514-02-2007 12:30:55

Page 30: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

30

Residential

R410A

HIGH-WALL SPLIT SYSTEM

COOLING ONLY/HEAT PUMPS

One touch pre-set

New anti-oxidant fi lter

Hi power

Auto diagnosis

Real time On/Off timer

High-wall Fixed-speed residential.

High-wall Fixed-speed residential.Features

These new elegant High-wall units are extremely compact, slim line units and blend in any room interior. These units present new outstanding features like the Vitamin C filter and the arc shape coil.These units are ideal for residential and commercial applications, such as offices, small shops and hotels.

Key features

Effi cient fi ltration system:Zeolite Plus and Sasa fi lter, the new anti-oxidant Vitamin C fi lter and the Gingko fi lter combined with the Bio Enzyme fi lter.

Innovative Toshiba Arc shape Coil:the increased heat exchanger surface ensure better air-fl ow.*

New aesthetics with the simple and elegant lines of the flat panel.

The slimmest unit of Toshiba range: 25% smaller and 30% lighter.*

* For size 7 and 10.

size 10

154322_Residential_brochure_06.i30 30154322_Residential_brochure_06.i30 30 14-02-2007 12:30:5614-02-2007 12:30:56

Page 31: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

31

Technical specifications cooling only

Technical specifications heat pump

Technical specifications cooling only and heat pump

* For residential applications, energy efficiency class C or above is recommended.

Outdoor unit RAS-10GA-ES2 RAS-13GA-ES2 RAS-18GA-ES2 RAS-24GA-ES2

Indoor unit RAS-10GKP-ES2 RAS-13GKP-ES2 RAS-18GKP-ES2 RAS-24GKP-ES2

Cooling capacity kW CO 2.73 3.75 5.33 6.83

Power input kW CO 0.84 1.15 1.91 2.63

EER W/W CO 3.25 3.26 2.79 2.60

Energy effi ciency class CO A A C D*

Annual energy consumption kWh CO 420 575 955 1315

Running current A 3.76 5.15 8.60 12.53

Outdoor unit RAS-10GA-ES2 RAS-13GA-ES2 RAS-18GA-ES2 RAS-24GA-ES2

Air fl ow m3/h - l/s CO 1740 - 483 2030 - 564 2120 - 589 3380 - 939

Sound pressure level dB(A) CO 46 50 51 56

Sound power level dB(A) CO 59 63 64 69

Dimensions (H x W x D) mm CO 550 x 780 x 290 550 x 780 x 290 550 x 780 x 290 715 x 780 x 290

Weight kg CO 30 38 39 63

Outdoor unit RAS-10GAH-ES2 RAS-13GAH-ES2 RAS-18GAH-ES2 RAS-24GAH-ES2

Indoor unit RAS-10GKHP-ES2 RAS-13GKHP-ES2 RAS-18GKHP-ES2 RAS-24GKHP-ES2

Cooling capacity kW CO 2.73 3.78 5.03 6.30

Power input kW CO 0.84 1.17 1.88 2.47

EER W/W CO 3.25 3.23 2.68 2.55

Energy effi ciency class CO A A D* E*

Annual energy consumption kWh CO 420 585 940 1235

Running current A CO 3.76 5.25 8.40 11.45

Heating capacity kW HP 2.94 4.23 5.50 6.85

Power input kW HP 0.81 1.16 1.72 2.44

COP W/W HP 3.63 3.65 3.20 2.81

Energy effi ciency class HP A A C D

Outdoor unit RAS-10GAH-ES2 RAS-13GAH-ES2 RAS-18GAH-ES2 RAS-24GAH-ES2

Air fl ow m3/h - l/s 2030 - 564 2120 - 589 1830 - 508 3380 - 939

Sound pressure level dB(A) CO (HP) 47 (47) 49 (49) 52 (53) 56 (57)

Sound power level dB(A) CO (HP) 60 (60) 62 (62) 65 (66) 69 (70)

Dimensions (H x W x D) mm 550 x 780 x 290 550 x 780 x 290 550 x 780 x 290 715 x 780 x 290

Weight kg 32 40 50 65

Indoor unit HP RAS-10GKHP-ES2 RAS-13GKHP-ES2 RAS-18GKHP-ES2 RAS-24GKHP-ES2

CO RAS-10GKP-ES2 RAS-13GKP-ES2 RAS-18GKP-ES2 RAS-24GKP-ES2

Air fl ow (h/l) m3/h - l/s CO 540/340 - 150/95 630/430 - 175/120 900/625 - 250/174 900/625 - 250/174

Air fl ow (h/l) m3/h - l/s HP 560/400 - 155/110 650/490 - 180/135 900/625 - 250/174 900/625 - 250/174

Sound pressure level (h/l) dB(A) 41/31 41/31 44/35 45/37

Sound power level dB(A) 54 54 57 58

Dimensions (H x W x D) mm 250 x 740 x 185 275 x 790 x 218 298 x 998 x 220 298 x 998 x 220

Weight kg 8 10 13 13

Outdoor unit HP RAS-10GAH-ES2 RAS-13GAH-ES2 RAS-18GAH-ES2 RAS-24GAH-ES2

CO RAS-10GA-ES2 RAS-13GA-ES2 RAS-18GA-ES2 RAS-24GA-ES2

Operating range °C CO 15 - 43°C 15 - 43°C 15 - 43°C 15 - 43°C

Operating range °C HP -10 - 24°C -10 - 24°C -10 - 24°C -10 - 24°C

Flare connections, Gas - Liquid in 3/8 -1/4 1/2 - 1/4 1/2 - 1/4 1/2 - 1/4

Maximum pipe length m 10 15 20 25

Maximum height difference m 5 6 8 10

Pre-charged pipe length m 10 15 15 15

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

154322_Residential_brochure_06.i31 31154322_Residential_brochure_06.i31 31 14-02-2007 12:30:5814-02-2007 12:30:58

Page 32: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Residential

32

R410A

HI POWER

ECO-LOGIC

6 in 1 filtering solution

Flexi Fixed-speed residential.

Flexi Fixed-speed residential.Features

The stylish GF-series console and ceiling-suspended units bring a touch of luxury to your life. They incorporate the latest Toshiba technology and are ideal for residential applications, offices and shops. The same unit can be used for low-wall or ceiling-suspended mounting, without modification.

Key features

Flexible for both low-wall and ceiling-suspended installations.

Effi cient fi ltration system:Zeolite Plus and Sasa fi lter, the new anti-oxidant Vitamin C fi lter and the Gingko fi lter combined with the Bio Enzyme fi lter.

Ahead of the class: “Hi Power” - reaches set-point temperature faster.

Light, compact and attractivedesign.

Fresh air intake facility at the back of the unit.

Self-cleaning function (RAS-GFP, GFHP-ES2 models only).

154322_Residential_brochure_06.i32 32154322_Residential_brochure_06.i32 32 14-02-2007 12:30:5914-02-2007 12:30:59

Page 33: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

33

Technical specifications cooling only

Technical specifications heat pump

Technical specifications cooling only and heat pump

Outdoor unit RAS-18GAH-ES2 RAS-24GAH-ES2

Indoor unit RAS-18GFHP-ES2 RAS-24GFHP-ES2

Cooling capacity kW CO 5.05 6.25

Power input kW CO 1.99 2.55

EER W/W CO 2.54 2.45

Energy effi ciency class CO E E

Annual energy consumption kWh CO 995 1275

Running current A CO 8.85 11.73

Heating capacity kW HP 5.73 7.05

Power input kW HP 1.86 2.48

COP W/W HP 3.08 2.84

Energy effi ciency class HP B C

Indoor unit CO RAS-18GFP-ES2 RAS-24GFP-ES2

HP RAS-18GFHP-ES2 RAS-24GFHP-ES2

Air fl ow (h/l) m3/h - l/s CO 800/580 - 220/160 930/650 - 250/180

Air fl ow (h/l) m3/h - l/s HP 830/650 - 230/180 930/660 - 260/183

Sound pressure level (h/l) dB(A) 43/36 46/37

Sound power level dB(A) 56 59

Dimensions (HxWxD) mm 633 x 1093 x 208 633 x 1093 x 208

Weight kg 23 23

Outdoor unit RAS-18GA-ES2 RAS-24GA-ES2

Indoor unit RAS-18GFP-ES2 RAS-24GFP-ES2

Cooling capacity kW CO 5.33 6.83

Power input kW CO 2.00 2.72

EER CO 2.67 2.51

Energy effi ciency class CO D* E*

Annual energy consumption kWh CO 1000 1360

Running current A CO 5.50 12.70

Outdoor unit CO RAS-18GA-ES2 RAS-24GA-ES2

HP RAS-18GAH-ES2 RAS-24GAH-ES2

Air fl ow m3/h - l/s 1920 - 535 3470 - 965

Sound pressure level dB(A) CO (HP) 51 (53) 56 (58)

Sound power level dB(A) CO (HP) 65 (66) 70 (71)

Operating range °C CO (HP) 15 - 43°C (-10 - 24°C) 15 - 43°C (-10 - 24°C)

Dimensions (HxWxD) mm 538 x 780 x 300 690 x 880 x 310

Weight kg CO (HP) 39 (50) 63 (65)

Flare connections, Gas - Liquid in 1/2 - 1/4 1/2 - 1/4

Maximum pipe length m 20 25

Maximum height difference m 8 10

Pre-charged pipe length m 15 15

Power supply V-ph-Hz 220/240-1-50 220/240-1-50

* For residential applications, energy efficiency class C or above is recommended.

154322_Residential_brochure_06.i33 33154322_Residential_brochure_06.i33 33 14-02-2007 12:31:0114-02-2007 12:31:01

Page 34: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Residential

34

R410A

DC HYBRID INVERTER

MULTI-SPLIT OUTDOOR UNITS

Smallest 5 hp unit in the market

Light weight

Up to 70 m of pipe run

Outdoor Multi-split residential.

Outdoor Multi-split residential.Features

Toshiba Multi-splits are equipped with Toshiba DC hybrid inverter, an enhanced air conditioning system that ensures greater performance and reliability.Thanks to the efficient DC compressors, this unit provides fast and precise temperature management, along with superior energy savings, 40-50% compared to fixed-speed systems.

Key features

Wider range of indoor units available: High-wall, Ducted and Daiseikai.

A perfect combination of DC Twin Rotary compressor, DC hybrid inverter and R410A Refrigerant.

Superior reliability, due to the reduction of the compressor ON/OFF cycles.

Compact and light: The smallest 5 hp outdoor unit in the industry at 795 x 900 x 320 mm.

Extremely quiet: the unit operates at only 48 dB(A).

Flexibility is assured with this system that enables up to 25 m piping length for one room ensuring the overall length is not exceeded. An example of a four room application where the overall length is 70 m - Room 1: 25 m, Room 2: 20 m, Rooms 2 and 4: 10 m each.

size 26 - 27 size 14 - 18

154322_Residential_brochure_06.i34 34154322_Residential_brochure_06.i34 34 14-02-2007 12:31:0214-02-2007 12:31:02

Page 35: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

35

Technical specifications cooling only

Technical specifications heat pump

2-room Multi-split 3-room Multi-split 4-room Multi-split

Outdoor unit RAS-M14GACV-E RAS-M18GACV-E 3M23GACV-E 4M27GACV-E

Cooling capacity kW CO 4.0 5.2 6.7 8.0

Cooling capacity (min. - max.) kW CO 1.1 - 4.5 1.1 - 6.2 1.4 - 7.0 1.4 - 9.2

Power input kW CO 1.08 1.60 2.15 2.50

EER W/W CO 3.70 3.25 3.12 3.20

Energy effi ciency class CO A A B A

Air fl ow m3/h - l/s 1820 - 505 2100 - 583 3000 - 833 3000 - 833

Sound pressure level dB(A) CO 46 48 48 48

Sound power level dB(A) CO 59 61 61 61

Operating range °C CO 5 - 43°C 5 - 43°C 10 - 43°C 10 - 43°C

Dimensions (HxWxD) mm 550 x 780 x 290 550 x 780 x 290 695 X 900 X 320 795 X 900 X 320

Weight kg 36 40 48 65

Compressor type DC Twin rotary DC Twin rotary DC Twin rotary DC Twin rotary

Flare connections

Gas in 3/8 x 2 3/8 x 2 3/8 x 2 + 1/2 3/8 x 3 + 1/2

Liquid in 1/4 x 2 1/4 x 2 1/4 x 3 1/4 x 4

Maximum pipe length

(per unit/total)

m 20/30 20/30 20/40 25/70

Maximum height difference m 10 10 10 15

Pre-charged pipe length m 20 20 40 70

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

2-room Multi-split 3-room Multi-split 4-room Multi-split

Outdoor unit RAS-M14GAV-E RAS-M18GAV-E 3M26GAV-E 4M27GAV-E

Cooling capacity kW CO 4.0 5.2 7.5 8.0

Cooling capacity (min. - max.) kW CO 1.1 - 4.5 1.1 - 6.2 1.4 - 8.9 1.4 - 9.2

Power input kW CO 1.08 1.60 2.25 2.50

EER W/W CO 3.70 3.25 3.33 3.20

Energy effi ciency class CO A A A B

Heating capacity kW HP 4.4 6.7 9.0 9.0

Heating capacity (min. - max.) kW HP 0.5 - 5.2 0.7 - 8.5 0.8 - 10.8 0.8 - 11.0

Power input kW HP 1.01 1.85 2.55 2.25

COP W/W HP 4.35 3.62 3.53 4.00

Energy effi ciency class HP A A B A

Air fl ow m3/h - l/s 1820 - 505 2100 - 583 3000 - 833 3000 - 833

Sound pressure level dB(A) CO 46 48 48 48

Sound power level dB(A) CO 59 61 61 61

Operating range °C CO 5 - 43°C 5 - 43°C 10 - 43°C 10 - 43°C

Sound pressure level dB(A) HP 48 50 48 48

Sound power level dB(A) HP 61 63 61 61

Operating range °C HP -10 - 24°C -10 - 24°C -10 - 21°C -10 - 21°C

Dimensions (HxWxD) mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320

Weight kg 36 40 64 65

Compressor type DC Twin rotary DC Twin rotary DC Twin rotary DC Twin rotary

Flare connections

Gas in 3/8 x 2 3/8 x 2 3/8 x 2 + 1/2 3/8 x 3 + 1/2

Liquid in 1/4 x 2 1/4 x 2 1/4 x 3 1/4 x 4

Minimum pipe length m 2 2 2 2

Maximum pipe length (per unit/

total)

m 20/30 20/30 25/50 25/70

Maximum height difference m 10 10 15 15

Pre-charged pipe length m 20 20 50 70

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

154322_Residential_brochure_06.i35 35154322_Residential_brochure_06.i35 35 14-02-2007 12:31:0314-02-2007 12:31:03

Page 36: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Residential

36

Cooling, 230V

Outdoor unit: RAS-M14GACV-E Indoor units: Daiseikai RAS-MxxGKCVP-E (sizes 10 and 13) GKV RAS-MxxGKCV-E (sizes 10 and 13) Ducted RAS-MxxGDCV-E (sizes 10 and 13)

Outdoor unit: RAS-M18GACV-E Indoor units: Daiseikai RAS-MxxGKCVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKCV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDCV-E (sizes 10, 13 and 16)

Cooling, 230V

The schemes are exemplifying. In dual, trial and quadri Multi-split the indoor units Daiseikai, GKV and Ducted are interchangeable.

Daiseikai

Daiseikai GKV

Daiseikai

Daiseikai

GKV

GDV (Ducted)

GDV (Ducted)

2 Rooms 2 Rooms

3 Rooms 4 Rooms

Daiseikai

GKV

GDV (Ducted)

Combination ratings (size 14) cooling only

Combination ratings (size 18) cooling only

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 2.5 - 1.1 2.5 3.2 170 570 880 1.06 2.92 4.11

13 - 3.5 - 1.1 3.5 3.8 170 1100 1280 1.06 5.03 5.80

2 unit operation 10 10 1.95 1.95 1.4 3.9 4.4 230 1070 1290 1.43 4.90 5.84

13 10 2.33 1.67 1.4 4.0 4.5 230 1080 1300 1.43 4.94 5.89

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 2.7 - 1.1 2.7 3.2 220 600 800 1.37 2.90 3.66

13 - 3.7 - 1.1 3.7 4.2 220 1100 1400 1.37 4.88 6.21

16 - 4.5 - 1.1 4.5 4.9 220 1500 1700 1.37 6.65 7.54

2 unit operation 10 10 2.55 2.55 1.4 5.1 6.1 260 1550 2150 1.61 6.88 9.54

13 10 2.85 2.35 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

13 13 2.60 2.60 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

16 10 3.25 1.95 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

154322_Residential_brochure_06.i36 36154322_Residential_brochure_06.i36 36 14-02-2007 12:31:0414-02-2007 12:31:04

Page 37: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

37

Outdoor unit: RAS-3M23GACV-E Indoor units: Daiseikai RAS-MxxGKCVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKCV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDCV-E (sizes 10, 13 and 16)

Cooling, 230VCombination ratings (size 23) cooling only

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - 2.7 - - 1.4 2.7 3.2 320 770 950 1.99 3.94 4.86

13 - - 3.7 - - 1.4 3.7 4.4 320 1200 1470 1.99 6.07 7.18

16 - - 4.5 - - 1.4 4.5 4.9 320 1600 1750 1.99 7.32 8.01

2 unit operation 10 10 - 2.7 2.7 - 1.8 5.4 6.0 360 1500 1880 2.24 6.86 8.6

10 13 - 2.45 3.35 - 1.8 5.8 6.3 360 1800 1970 2.24 8.24 9.02

10 16 - 2.21 3.69 - 1.8 5.9 6.4 360 1830 2000 2.24 8.38 9.15

13 13 - 2.95 2.95 - 1.8 5.9 6.4 360 1830 2000 2.24 8.38 9.15

13 16 - 2.71 3.29 - 1.8 6 6.4 360 1850 2000 2.24 8.5 9.15

16 16 - 3.05 3.05 - 1.8 6.1 6.5 360 1870 2050 2.24 8.56 9.38

3 unit operation 10 10 10 2.13 2.13 2.13 2.2 6.4 7.0 420 1880 2300 2.61 8.6 10.53

10 10 13 1.99 1.99 2.72 2.2 6.7 7.0 420 2150 2300 2.61 9.84 10.53

10 13 13 1.8 2.45 2.45 2.2 6.7 7.0 420 2150 2300 2.61 9.84 10.53

10 10 16 1.83 1.83 3.04 2.2 6.7 7.0 420 2150 2300 2.61 9.84 10.53

Outdoor unit: RAS-4M27GACV-E Indoor units: Daiseikai RAS-MxxGKCVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKCV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDCV-E (sizes 10, 13 and 16)

Cooling, 230VCombination ratings (size 27) cooling only

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - - 2.7 - - - 1.4 2.7 3.2 640 750 950 3.52 3.71 4.44

13 - - - 3.7 - - - 1.4 3.7 4.4 640 1200 1520 3.52 5.49 6.88

16 - - - 4.5 - - - 1.4 4.5 5 640 1650 2000 3.52 7.47 8.87

2 unit operation 10 10 - - 2.7 2.7 - - 2.5 5.4 6.3 640 1530 2040 3.48 6.79 9.05

13 10 - - 3.41 2.49 - - 2.7 5.9 6.6 660 1810 2220 3.59 8.03 9.85

16 10 - - 3.94 2.36 - - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

13 13 - - 3.15 3.15 - - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

16 13 - - 3.73 3.07 - - 3 6.8 7.2 690 2320 2570 3.75 10.29 11.40

16 16 - - 3.6 3.6 - - 3.2 7.2 7.5 700 2550 2750 3.8 11.31 12.2

3 unit operation 10 10 10 - 2.53 2.53 2.53 - 3.8 7.6 8.2 950 2400 2720 4.59 10.65 12.07

13 10 10 - 3.13 2.28 2.28 - 3.9 7.7 8.3 960 2410 2740 4.64 10.69 12.16

16 10 10 - 3.5 2.1 2.1 - 4 7.7 8.5 960 2410 2790 4.64 10.69 12.38

13 13 10 - 2.82 2.82 2.06 - 4 7.7 8.5 960 2410 2790 4.64 10.69 12.38

16 13 10 - 3.22 2.65 1.93 - 4.1 7.8 8.6 970 2430 2810 4.69 10.78 12.47

13 13 13 - 2.6 2.6 2.6 - 4.1 7.8 8.6 970 2430 2810 4.69 10.78 12.47

16 16 10 - 3.04 3.04 1.82 - 4.1 7.9 8.7 970 2440 2830 4.69 10.83 12.56

16 13 13 - 2.99 2.46 2.46 - 4.1 7.9 8.7 970 2440 2830 4.69 10.83 12.56

16 16 13 - 2.8 2.8 2.3 - 4.2 7.9 8.9 970 2440 2880 4.69 10.83 12.78

16 16 16 - 2.67 2.67 2.67 - 4.3 8 9 980 2450 2900 4.73 10.87 12.87

4 unit operation 10 10 10 10 1.98 1.98 1.98 1.98 4 7.9 8.7 930 2450 2800 4.49 10.87 12.42

13 10 10 10 2.48 1.81 1.81 1.81 4.1 7.9 8.8 940 2450 2820 4.54 10.87 12.51

16 10 10 10 2.86 1.71 1.71 1.71 4.1 8 9 940 2500 2860 4.54 11.09 12.69

13 13 10 10 2.31 2.31 1.69 1.69 4.1 8 9 940 2500 2860 4.54 11.09 12.69

16 13 10 10 2.65 2.18 1.59 1.59 4.2 8 9.1 950 2500 2880 4.59 11.09 12.78

13 13 13 10 2.14 2.14 2.14 1.57 4.2 8 9.1 950 2500 2880 4.59 11.09 12.78

16 13 13 10 2.47 2.03 2.03 1.48 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

13 13 13 13 2 2 2 2 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

16 16 10 10 2.5 2.5 1.5 1.5 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

154322_Residential_brochure_06.i37 37154322_Residential_brochure_06.i37 37 14-02-2007 12:31:0914-02-2007 12:31:09

Page 38: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

38

Residential

Cooling, 230V

Combination ratings (size 14) heat pump

Outdoor unit: RAS-M18GAV-E Indoor units: Daiseikai RAS-BxxGKVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDV-E (sizes 10, 13 and 16)

Cooling, 230V

Combination ratings (size 18) heat pump

Outdoor unit: RAS-M14GAV-E Indoor units: Daiseikai RAS-BxxGKVP-E (sizes 10 and 13) GKV RAS-MxxGKV-E (sizes 10 and 13) Ducted RAS-MxxGDV-E (sizes 10 and 13)

Heating, 230V

Heating, 230V

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 2.5 - 1.1 2.5 3.2 170 570 880 1.06 2.92 4.11

13 - 3.5 - 1.1 3.5 3.8 170 1100 1280 1.06 5.03 5.80

2 unit operation 10 10 1.95 1.95 1.4 3.9 4.4 230 1070 1290 1.43 4.90 5.84

13 10 2.33 1.67 1.4 4 4.5 230 1080 1300 1.43 4.94 5.89

Operating status Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 3.2 - 0.7 3.2 4 130 850 1280 0.81 3.89 6.41

13 - 4.2 - 0.7 4.2 4.4 130 1250 1350 0.81 5.60 6.86

2 unit operation 10 10 2.15 2.15 0.9 4.3 4.6 170 980 1230 1.06 4.39 5.51

13 10 2.5 1.9 0.9 4.4 4.7 170 1010 1250 1.06 4.53 5.60

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 2.7 - 1.1 2.7 3.2 220 600 800 1.37 2.90 3.66

13 - 3.7 - 1.1 3.7 4.2 220 1100 1400 1.37 4.88 6.21

16 - 4.5 - 1.1 4.5 4.9 220 1500 1700 1.37 6.65 7.54

2 unit operation 10 10 2.55 2.55 1.4 5.1 6.1 260 1550 2150 1.61 6.88 9.54

13 10 3.01 2.19 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

13 13 2.6 2.6 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

16 10 3.25 1.95 1.4 5.2 6.2 260 1600 2170 1.61 7.10 9.63

Operating status Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit A Unit B Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - 4 - 0.7 4 5.2 170 1200 1700 1.06 5.32 7.54

13 - 5 - 0.7 5 6.5 170 1800 2530 1.06 7.99 11.22

16 - 5.5 - 0.7 5.5 6.9 170 1900 2530 1.06 8.43 11.22

2 unit operation 10 10 3.2 3.2 0.9 6.4 8.3 200 1800 2390 1.24 7.99 10.60

13 10 3.72 2.98 0.9 6.7 8.7 200 1850 2450 1.24 8.21 10.87

13 13 3.35 3.35 0.9 6.7 8.7 200 1850 2450 1.24 8.21 10.87

16 10 3.88 2.82 0.9 6.7 8.7 200 1850 2450 1.24 8.21 10.87

154322_Residential_brochure_06.i38 38154322_Residential_brochure_06.i38 38 14-02-2007 12:31:1014-02-2007 12:31:10

Page 39: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

39

Cooling, 230V

Outdoor unit: RAS-3M26GAV-E Indoor units: Daiseikai RAS-BxxGKVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDV-E (sizes 10, 13 and 16)

Heating, 230V

Combination ratings (size 26) heat pump

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - 2.7 - - 1.4 2.7 3.2 640 750 950 3.52 3.71 4.44

13 - - 3.7 - - 1.4 3.7 4.4 640 1200 1520 3.52 5.49 6.88

16 - - 4.5 - - 1.4 4.5 5 640 1650 2000 3.52 7.47 8.87

2 unit operation 10 10 - 2.7 2.7 - 2.5 5.4 6.3 640 1530 2040 3.48 6.79 9.05

13 10 - 3.41 2.49 - 2.7 5.9 6.6 660 1810 2220 3.59 8.03 9.85

16 10 - 3.94 2.36 - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

13 13 - 3.15 3.15 - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

16 13 - 3.73 3.07 - 3 6.8 7.2 690 2320 2570 3.75 10.29 11.4

16 16 - 3.6 3.6 - 3.2 7.2 7.5 700 2550 2750 3.8 11.31 12.2

3 unit operation 10 10 10 2.47 2.47 2.47 3.6 7.4 8.2 950 2230 2720 4.59 9.89 12.07

13 10 10 3.01 2.2 2.2 3.9 7.4 8.3 950 2230 2750 4.59 9.89 12.2

16 10 10 3.36 2.02 2.02 4 7.4 8.5 950 2230 2820 4.59 9.89 12.51

13 13 10 2.71 2.71 1.98 4 7.4 8.5 950 2230 2820 4.59 9.89 12.51

16 13 10 3.1 2.55 1.86 4 7.5 8.6 980 2250 2850 4.73 9.98 12.64

13 13 13 2.5 2.5 2.5 4 7.5 8.6 980 2250 2850 4.73 9.98 12.64

16 16 10 2.88 2.88 1.73 4.1 7.5 8.8 980 2250 2920 4.73 9.98 12.95

16 13 13 2.84 2.33 2.33 4.1 7.5 8.8 980 2250 2920 4.73 9.98 12.95

16 16 13 2.66 2.66 2.19 4.2 7.5 8.9 980 2250 2950 4.73 9.98 13.09

Operating status Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit A Unit B Unit C Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - 4 - - 0.8 4 5.2 300 1500 1980 1.79 6.65 8.78

13 - - 5 - - 0.8 5 6.5 310 2050 2750 1.85 9.09 12.2

16 - - 5.5 - - 0.8 5.5 6.9 310 2400 3000 1.85 10.65 13.31

2 unit operation 10 10 - 3.6 3.6 - 1.5 7.2 10 320 2050 3200 1.86 9.09 14.2

13 10 - 4.22 3.38 - 1.5 7.6 10.1 320 2240 3210 1.86 9.94 14.24

16 10 - 4.57 3.33 - 1.5 7.9 10.1 320 2380 3230 1.86 10.56 14.33

13 13 - 3.95 3.95 - 1.5 7.9 10.1 320 2380 3230 1.86 10.56 14.33

16 13 - 4.35 3.95 - 1.5 8.3 10.2 320 2560 3240 1.86 11.36 14.37

16 16 - 4.3 4.3 - 1.5 8.6 10.2 320 2700 3250 1.86 11.98 14.42

3 unit operation 10 10 10 2.87 2.87 2.87 2 8.6 10.4 380 2300 2750 2.07 10.2 12.2

13 10 10 3.35 2.68 2.68 2 8.7 10.5 380 2360 2760 2.07 10.47 12.24

16 10 10 3.59 2.61 2.61 2 8.8 10.6 380 2430 2780 2.07 10.78 12.33

13 13 10 3.14 3.14 2.51 2 8.8 10.6 380 2430 2780 2.07 10.78 12.33

16 13 10 3.34 3.03 2.43 2 8.8 10.6 380 2430 2780 2.07 10.78 12.33

13 13 13 2.93 2.93 2.93 2 8.8 10.6 380 2430 2780 2.07 10.78 12.33

16 16 10 3.26 3.26 2.37 2 8.9 10.7 380 2490 2790 2.07 11.05 12.38

16 13 13 3.16 2.87 2.87 2 8.9 10.7 380 2490 2790 2.07 11.05 12.38

16 16 13 3.09 3.09 2.81 2 9 10.8 380 2550 2800 2.07 11.31 12.42

154322_Residential_brochure_06.i39 39154322_Residential_brochure_06.i39 39 14-02-2007 12:31:1214-02-2007 12:31:12

Page 40: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

40

Residential

Cooling, 230V

Combination ratings (size 27) heat pump

Operating status Combination Unit capacity (kW) Cooling capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - - 2.7 - - - 1.4 2.7 3.2 640 750 950 3.52 3.71 4.44

13 - - - 3.7 - - - 1.4 3.7 4.4 640 1200 1520 3.52 5.49 6.88

16 - - - 4.5 - - - 1.4 4.5 5 640 1650 200 3.52 7.47 8.87

2 unit operation 10 10 - - 2.7 2.7 - - 2.5 5.4 6.3 640 1530 2040 3.48 6.79 9.05

13 10 - - 3.41 2.49 - - 2.7 5.9 6.6 660 1810 2220 3.59 8.03 9.85

16 10 - - 3.94 2.36 - - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

13 13 - - 3.15 3.15 - - 2.9 6.3 6.9 670 2040 2400 3.64 9.05 10.65

16 13 - - 3.73 3.07 - - 3 6.8 7.2 690 2320 2570 3.75 10.29 11.4

16 16 - - 3.6 3.6 - - 3.2 7.2 7.5 700 2550 2750 3.8 11.31 12.2

3 unit operation 10 10 10 - 2.53 2.53 2.53 - 3.6 7.6 8.2 950 2400 2720 4.59 10.65 12.07

13 10 10 - 3.13 2.28 2.28 - 3.9 7.7 8.3 960 2410 2740 4.64 10.69 12.16

16 10 10 - 3.5 2.1 2.1 - 4 7.7 8.5 960 2410 2790 4.64 10.69 12.38

13 13 10 - 2.82 2.82 2.06 - 4 7.7 8.5 960 2410 2790 4.64 10.69 12.38

16 13 10 - 3.22 2.65 1.93 - 4.1 7.8 8.6 970 2430 2810 4.69 10.78 12.47

13 13 13 - 2.6 2.6 2.6 - 4.1 7.8 8.6 970 2430 2810 4.69 10.78 12.47

16 16 10 - 3.04 3.04 1.82 - 4.1 7.9 8.7 970 2440 2830 4.69 10.83 12.56

16 13 13 - 2.99 2.46 2.46 - 4.1 7.9 8.7 970 2440 2830 4.69 10.83 12.56

16 16 13 - 2.8 2.8 2.3 - 4.2 7.9 8.9 970 2440 2880 4.69 10.83 12.78

16 16 16 - 2.67 2.67 2.67 - 4.3 8 9 980 2450 2900 4.73 10.87 12.87

4 unit operation 10 10 10 10 1.98 1.98 1.98 1.98 4 7.9 8.7 930 2450 2800 4.49 10.87 12.42

13 10 10 10 2.48 1.81 1.81 1.81 4.1 7.9 8.8 940 2450 2820 4.54 10.87 12.51

16 10 10 10 2.86 1.71 1.71 1.71 4.1 8 9 940 2500 2860 4.54 11.09 12.69

13 13 10 10 2.31 2.31 1.69 1.69 4.1 8 9 940 2500 2860 4.54 11.09 12.69

16 13 10 10 2.65 2.18 1.59 1.59 4.2 8 9.1 950 2500 2880 4.59 11.09 12.78

13 13 13 10 2.14 2.14 2.14 1.57 4.2 8 9.1 950 2500 2880 4.59 11.09 12.78

16 13 13 10 2.47 2.03 2.03 1.48 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

13 13 13 13 2 2 2 2 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

16 16 10 10 2.5 2.5 1.5 1.5 4.2 8 9.2 950 2500 2900 4.59 11.09 12.87

154322_Residential_brochure_06.i40 40154322_Residential_brochure_06.i40 40 14-02-2007 12:31:1314-02-2007 12:31:13

Page 41: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

41

Outdoor unit: RAS-4M27GAV-E Indoor units: Daiseikai RAS-BxxGKVP-E (sizes 10, 13 and 16) GKV RAS-MxxGKV-E (sizes 10, 13 and 16) Ducted RAS-MxxGDV-E (sizes 10, 13 and 16)

Combination ratings (size 27) heat pump

Energy Labeling InformationCooling-only

Heat pump

Heating, 230V

Operating status Combination Unit capacity (kW) Heating capacity (kW) Power input (W) Operating current (A)

Unit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min. Rated Max. Min. Rated Max. Min. Rated Max.

1 unit operation 10 - - - 4 - - - 0.8 4 5.2 300 1450 1980 1.79 6.43 8.78

13 - - - 5 - - - 0.8 5 6.5 310 2050 2750 1.85 9.09 12.2

16 - - - 5.5 - - - 0.8 5.5 6.9 310 2400 3000 1.85 10.65 13.31

2 unit operation 10 10 - - 3.6 3.6 - - 1.5 7.2 10 320 2100 3200 1.86 9.32 14.2

13 10 - - 4.22 3.38 - - 1.5 7.6 10.1 320 2320 3210 1.86 10.29 14.24

16 10 - - 4.57 3.33 - - 1.5 7.9 10.1 320 2480 3230 1.86 11 14.33

13 13 - - 3.95 3.95 - - 1.5 7.9 10.1 320 2480 3230 1.86 11 14.33

16 13 - - 4.35 3.95 - - 1.5 8.3 10.2 320 2700 3240 1.86 11.98 14.37

16 16 - - 4.3 4.3 - - 1.5 8.6 10.2 320 2860 3250 1.86 12.69 14.42

3 unit operation 10 10 10 - 2.87 2.87 2.87 - 2 8.6 10.4 380 2300 2750 2.07 10.20 12.2

13 10 10 - 3.35 2.68 2.68 - 2 8.7 10.5 380 2350 2760 2.07 10.43 12.24

16 10 10 - 3.54 2.58 2.58 - 2 8.7 10.5 380 2350 2760 2.07 10.43 12.24

13 13 10 - 3.11 3.11 2.49 - 2 8.7 10.5 380 2350 2780 2.07 10.43 12.24

16 13 10 - 3.34 3.03 2.43 - 2 8.8 10.6 380 2400 2780 2.07 10.65 12.33

13 13 13 - 2.93 2.93 2.93 - 2 8.8 10.6 380 2400 2790 2.07 10.65 12.33

16 16 10 - 3.26 2.26 2.37 - 2 8.9 10.7 380 2450 2790 2.07 10.87 12.38

16 13 13 - 3.16 2.87 2.87 - 2 8.9 10.7 380 2450 2790 2.07 10.87 12.38

16 16 13 - 3.06 3.06 2.78 - 2 8.9 10.7 380 2450 2790 2.07 10.87 12.38

16 16 16 - 3 3 3 - 2 9 10.8 380 2500 2800 2.07 11.09 12.42

4 unit operation 10 10 10 10 2.23 2.23 2.23 2.23 2.2 8.9 10.8 450 2100 2810 2.45 9.32 12.47

13 10 10 10 2.62 2.09 2.09 2.09 2.2 8.9 10.9 460 2100 2830 2.5 9.32 12.56

16 10 10 10 2.83 2.06 2.06 2.06 2.2 9 10.9 460 2250 2830 2.5 9.98 12.56

13 13 10 10 2.5 2.5 2 2 2.2 9 10.9 470 2250 2830 2.55 9.98 12.56

16 13 10 10 2.68 2.43 1.95 1.95 2.2 9 11 480 2250 2850 2.61 9.98 12.64

13 13 13 10 2.37 2.37 2.37 1.89 2.2 9 11 480 2250 2850 2.61 9.98 12.64

16 13 13 10 2.54 2.31 2.31 1.85 2.2 9 11 490 2250 2850 2.66 9.98 12.64

13 13 13 13 2.25 2.25 2.25 2.25 2.2 9 11 490 2250 2850 2.66 9.98 12.64

16 16 10 10 2.61 2.61 1.89 1.89 2.2 9 11 500 2250 2850 2.72 9.98 12.64

Rooms Outdoor unit Indoor unit type Energy

class

Anual Energy consumption

(kW h in cooling mode)

Energy eff. ratio, EER

Unit A Unit B Unit C Unit D (kW h )

2 rooms RAS M14GACV-E 10 10 A 535 3.64

RAS M18GACV-E 10 10 A 775 3.29

13 13 A 800 3.25

3 rooms RAS 3M23GACV-E 10 10 10 A 940 3.40

4 rooms RAS 4M27GACV-E 10 10 10 10 A 1225 3.22

13 13 13 13 B 1250 3.20

COOLING HEATINGRooms Outdoor unit Indoor unit type Energy

class

Anual Energy consumption

(kW h )

Energy eff. ratio,

EER

Energy

class

Energy eff. ratio,

COP

Unit A Unit B Unit C Unit D

2 rooms RAS M14GAV-E 10 10 A 535 3.64 A 4.38

RAS M18GAV-E 10 10 A 775 3.29 A 3.61

13 13 A 800 3.25 A 3,62

3 rooms RAS 3M26GAV-E 10 10 10 A 1115 3.32 A 3,73

13 13 13 A 1125 3.33 A 3,62

4 rooms RAS 4M27GAV-E 10 10 10 10 A 1225 3.22 A 4,23

13 13 13 13 B 1250 3.20 A 4,00

154322_Residential_brochure_06.i41 41154322_Residential_brochure_06.i41 41 14-02-2007 12:31:1614-02-2007 12:31:16

Page 42: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

42

Notes

154322_Residential_brochure_06.i42 42154322_Residential_brochure_06.i42 42 14-02-2007 12:31:1714-02-2007 12:31:17

Page 43: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

43

Notes

154322_Residential_brochure_06.i43 43154322_Residential_brochure_06.i43 43 14-02-2007 12:31:1714-02-2007 12:31:17

Page 44: 154322 Residential brochure 06 - Cotarcoac.cotarco.com/downloads/Residential system brochure.pdfToshiba is the best investment for the enhanced well-being of the family environment.

Toshiba Carrier UK Ltd

United Technologies House

Guildford Road

Leatherhead

Surrey KT22 9UT

Tel: 01372 220240

Fax: 01372 220241

[email protected]

T/UK/RC 01.2007. The manufacturer reserves the right to change the product specifications and images without notice.

154322_Residential_brochure_06.i44 44154322_Residential_brochure_06.i44 44 14-02-2007 12:31:1714-02-2007 12:31:17