Page 1: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

150 E. Arrow Hwy. San Dimas, CA. 91773

909-599-0690 www.taloninst.com

Page 2: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Presentation Contents:Presentation Contents:• HardwareHardware

• SR192A MotherboardSR192A Motherboard• SR192A I/O ModulesSR192A I/O Modules

• SoftwareSoftware• SR192A Project Development SoftwareSR192A Project Development Software

Page 3: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192A

VXI Digital Stimulus/ResponseVXI Digital Stimulus/ResponseUp to 192 bi-directional I/O channels

““C” Size 2-Slot VXI ModelC” Size 2-Slot VXI ModelVXI Plug&Play Compatible

Modular DesignModular DesignUp to 12 I/O modules, 2 timing

modules.

Page 4: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192A

•J7 – Multi-unit operation•Up to 6 SR192A’s per 13 slot chassis

•J1 to J6 – I/O channels

•J8 – Timing signals from TSA and TSB

•J9 – SR211 Data Probe Interface

•J10 – External power input for Programmable I/O modules

Page 5: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192AMotherboardMotherboard•Houses up to 12 I/O modules•Up to 2 timing modules (Synchronous or Asynchronous Operation)

I/O and Timing Modules

CPU and VXI

Interface

Page 6: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192AI/O ModulesI/O Modules

The SR192A can accommodate different type of I/O Modules:

• SR124A – 8 channel TTL/RS-485 differential, per-pin selectable, 256K memory, Algorithmic

•SR125A – 16 channel TTL, 256K memory, Algorithmic

•SR214A – 16 channel variable voltage (+7 -- -5vdc), Voltage groups selectable per 8 channels, 256K memory, Algorithmic

•SR126A – 8 channels LVDS, 256K memory, Algorithmic

•All I/O modules are comprised of a 5 memories (Output, Tristate, Expect, Mask and Record

I/O Modules (12 slots)

Page 7: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192ATiming ModulesTiming Modules

The SR192A Timing Modules provide the timing and clock source required for the I/O Modules

• Up to 100Mhz (10Hz – 100Mhz on-board clock generator)

•5nS timing resolution

•1nS – 20nS Delay Adjustment on Input Strobes/Output Enables

•16 Timing Sets per Timing Module

•6 Output enables/Input strobes per Timing Module

•5 User defined outputs

•Up to 4K sequences

Timing Modules

Page 8: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

Talon Talon InstrumentsInstrumentsSR192ASR192AVector BusVector Bus

The SR192A Vector Bus provides extremely fast response timing to/from the UUT

• 4 Bit Lookup Table

•1 of 16 words

•1 Data cycle UUT response

Vector Bus

Page 9: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Microsoft Windows Based•Win95,98 or NT compatible

Graphical Software Editor•Hardware set-up•Test program development•Interactive test execution

Test Language Compatibility•Test files compatible with any Windows based test language, (“C”, C++, LabWindows, LabView, VEE, Visual Basic, etc.)

SR192A softwarealso includes

VXI Plug&Play compatibleWin95,98 & NT drivers.

Page 10: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Select the SR192A(from 1 to 6)

Data Tables (1 word table to 256K word

table

Timing Sets (up to 16 per timing module

Page 11: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Select the type of I/O module installed

• I/O module type can be mixed and matched based on logic interface requirement

Page 12: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Select single or multiple unit

Internal or External Clock Source

Page 13: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Select type of trigger input to

Timing module. TestInput can be a dedicated

Timing signal or I/OChannel(s)

Select type of sequence jump trigger

Page 14: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Define channelGroup(s)

Assign output

enable/input strobe

• All output enables/input strobes are per 8 channels

•Multiple groups of 8 channels can be assigned to the same output enable/input strobe

Page 15: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Define channelType (BiDir, Input,

Output)

Red indicates stimulus data/Blue indicates

response expect

Tri-state define

Page 16: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development Editor

Define when/how output enables/input

strobes are

controlled

TSES1 – TSES5 are used for

enables/strobes

TS_CLK = Timing clock up to 100MHz

Example: data_bus_en is

asserted for 5nS and disabled for 35nS

Page 17: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

SR192ASR192AProject Development EditorProject Development EditorSequence EditorSequence Editor

Up to 4K sequences can be defined. A

sequence is comprised of a Timing set and

Data Table

Select Timing Set/Data Table and Transition

type

Page 18: 150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 .

150 E. Arrow Hwy. San Dimas, CA. 91773 909-599-0690 www.taloninst.com

End of SR192A Presentation

For more information, please contact Talon Instruments