© 2007 Hew lett-Packard Development Company, L.P. The information contained herein is subject to change w ithout notice Technology for better business outcomes Insight Control Power Management Erik Hjalmarsson
12
Welcome message from author
This document is posted to help you gain knowledge. Please leave a comment to let me know what you think about it! Share it to your friends and learn new things together.
Transcript
Page 1: 15. Insight_Power_Manager.ppt

© 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice

Technology for better business outcomes

Insight Control Power Management

Erik Hjalmarsson

Page 2: 15. Insight_Power_Manager.ppt

:Problem Trapped Capacity Costs You $$$$

Racks in data center are half empty, but no more energy budget available!

Trapped powercapacity

+ =Lack of

Measurement You can’t improve what

you can’t measure

Lack ofControl

Makes it difficult to budget power

resources

*Source “Cost Model: Dollars per kW plus Dollars per Square Foot of Computer Floor”, W. Pitt Turner IV, P.E. with Kenneth G. Brill, Uptime Institute, 2008

!Capacity is prec ious1000 Wof redundant

infras tructure cos ts

$25,000*

!

Page 3: 15. Insight_Power_Manager.ppt

Trapped Capacity(up to 2x Actual)

Triple Your Data Center Capacity!

Opportunity

Pow

er (KW

)

Your Data Center Today

Time (hrs)

Total KWhr = energy bill ($$$)

Actual Power Peak

Power Budgeted by Facilities

}Real-time Energy Consumption

Page 4: 15. Insight_Power_Manager.ppt

HP Thermal LogicUnlocks Your Data Center’s True Potential

Reduce Energy• Up to 24% reduction in energy

consumption• Up to $330,000/yr savings (1MW data center)

R E D U C E

R E C L A I M Reclaim Capacity• Up to 220% capacity improvement!• $16M capital recovery (1MW data center)

E X T E N D

Extend the Life of the Data Center• Energy optimized across complete

ecosystem: from power delivery thru cooling infrastructure

• New EYP Energy-efficiency services

Page 5: 15. Insight_Power_Manager.ppt

5

HP Thermal Logic: Reduce total energy usage with industry’s most energy efficient design

460 5BL c G

•Redesigned to maximize energy efficiency

•41W (or more) savings per server compared to G1

•653W per enclosure saved at 100% utilization

•$1,372 in electricity savings over 3 years @ $0.08/kwHr

*meets latest EPA ENERGY STAR® Program Requirements for Computer Servers, DRAFT 3

38% betterPerformance/W Than Dell M600!

HP 2450W High Efficiency Power Supply

• Increased power output, allowing more blades to run with fewer supplies

• Lower standby power for reduced power consumption when servers are idle

• Exceeds EPA Energy-Star*, 80%+, and Climate Savers standards

Page 6: 15. Insight_Power_Manager.ppt

746

1943

1838

1331

959

0 500 1000 1500 2000 2500

21IBMHS

600Dell M

460 5BL c G

2 220 5BL x c G

260 5BL c G

HP Thermal Logic: Reduce with the industry’s most energy efficient blade server portfolio

Power Effic iency Leaders hip *for Specjbb indus try benchmark

/SPECjbb BOPS W

102% overDell!

*Internal HP testing on HP ProLiant Blades vs. best published values from Dell & IBM

most energy efficient 2 socket blade

for grid and high performance computing

“go to” server for general apps

Page 7: 15. Insight_Power_Manager.ppt

HP Thermal Logic - Set you own face plate with Dynamic Power Capping

• Set unique cap for each server• Cap stays fixed for each server

until adjusted

HP BladeSys temEnclos ure HP ProLiant DL

Server

• Set one cap for entire enclosure• Onboard Administrator adjusts

blade caps based on workload requirements

Noperformanceimpact

Page 8: 15. Insight_Power_Manager.ppt

*single circuit, 30-Amp, 3-Phase PDU

Triple ProLiant capacity* without additional capital investment with Dynamic Power Capping for DL Servers

Total Circuit Size = 8.6kWFace Plate = 1217W

7 Fit s ervers

Power Calc. = 450W Cap @ 100% = 368W

19 Fit s ervers

23 Fit s ervers

225% mores ervers

Page 9: 15. Insight_Power_Manager.ppt

* Each circuit, 60-Amp, 3-Phase PDU

Face Plate: 7836W

Double* ProLiant blades capacity without additional capital investment with Dynamic Power Capping

78% moreBlades

100% moreBlades

BL460c G

5

Total Circuit Size = 17.2kW

Power Calculator: 7517W

BL460c G1

Cap @ 80%: 5760

Cap @ 100%: 427532 460 1 c G blades

45 460 1 c G blades

64 460 5 c G blades

57 460 1 c G blades

Page 10: 15. Insight_Power_Manager.ppt

Dynamic Power Capping Component Release Matrix and Schedule

• Supported blade servers: BL 2x220c, BL260c, BL460c G1, BL460c G5, BL465c G5, BL685c, BL495c

• Supported DL servers: DL360 G5, DL380 G5• Will make production firmware available based on “customer request”

starting November 17.

Required Components

Version Blade Servers

DL Servers

Release Date Comment

ROM 10/1/2008 Required Required 11/17/2008

iLO* 1.70 Required Required 12/15/2008 Delayed due to TS&U bundling.

OA 2.30 Required N/A 12/15/2008

IPM (ICE upgrade)

2.0 Optional Optional 11/17/2008

Page 11: 15. Insight_Power_Manager.ppt

Product SKUs

HP Insight Power Manager License including 1 year of 24x7 Technical Support and Updates , Electronic

T9079AAE

HP Insight Power Manager, No Media, 1-Server License, including 1 year of 24x7 Technical Support and Updates

452677-B21

HP Insight Power Manager, No Media, Flexible-Quantity License, including 1 year of 24x7 Technical Support and Updates

452678-B21

HP Insight Power Manager, No Media Tracking License without 1 year of 24x7 Technical Support and Updates.

433693-B21

HP Insight Power Manager, No Media, Tracking License including 1 year of 24x7 Technical Support and Updates

453897-B21

HP Insight Power Manager 2.4

Along with iLO 1.7 and Onboard Adminstrator 2.3 for Blade servers.

Page 12: 15. Insight_Power_Manager.ppt

Screen Shots: