Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
142
Disco
nn
ect Enclo
sures
1447A Single Door Disconnect Enclosures - NEMA 12, 13Allen Bradley
Wallm
ou
nt En
closu
res
Enclosures 1447A K122 and 1447AL122 accept a 200 A switch only.This switch will not fit in any other1447A Series Enclosure. Order AllenBradley 1494F-L4 door hardware for1447A K122 and 1447A L122enclosures.
FinishDoor and enclosure arephosphatized and finished in ANSI/ASA 61 gray recoatable powdercoating on the outside.Enclosure interior is finished in whitepowder coating.Inner panel is finished in whitepowder coating.
ApplicationDesigned to house Allen Bradley1494F flange mounted disconnectswitches and 1494D flange mountedcircuit breaker operators (will notaccept Allen Bradley 1494Vdisconnect switches).Provides a degree of protection fromfalling dirt, dust, oil and water.
StandardsUL 508 Type 12, 13CSA Type 12, 13Complies with
NEMA Type 12, 13JIC EGP-1-1967IEC 529, IP65
Appropriate components arerequired to maintain thesestandards.
ConstructionFormed 14 gauge steel.Continuously welded seams.Larger sizes include door and bodystiffeners.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Cutouts and holes are provided tosuit the handle, operatingmechanism and door closingmechanism.
Continuously hinged doors may beremoved by pulling the hinge pin.Guide and cover interlock bracketsare welded to the door.Cover latch bars for door hardwareare provided.A spacer kit to support thedisconnect on the panel is included.Collar studs are provided formounting inner panels.A removable 12 gauge inner panel isincluded.Oil resistant gaskets arepermanently secured andmechanically retained.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided.
NoteDisconnects, operating mechanisms,and door hardware are not providedwith the enclosure, and must beordered separately from themanufacturer.Enclosures with an "A" dimensionunder 40" require 2 point doorclosing hardware. Order one AllenBradley 1494F-L1.Enclosures with an "A" dimension of40" or more require a 3 point doorclosing mechanism. Order one AllenBradley 1494F-L2 and one 1494F-L3.
➊ Vertical body stiffener req’d on 1447AG only.➋ Omit center body stiffener if A is less than 41".➌ Omit 2 middle studs if A is less than 31".➍ Omit body stiffeners if B is 28" or less.➎ Omit 2 middle studs if B is less than 32".➏ Omit door stiffener if B is 32" or less except if AxB is
Enclosures with an "A" dimensionunder 40" require two point doorlatching hardware, order: oneAllen Bradley 1494F-L1.Enclosures with an "A" dimensionof 40" or more require a 3 pointdoor latching mechanism, order:one Allen Bradley 1494F-L2 andone 1494F-L3.Exception: Order Allen Bradley1494F-L4 door hardware for1447A K122 and 1447A L122.
Enclosures with an "A" dimensionunder 40" require two point doorlatching hardware, order: oneAllen Bradley 1494F-L1.Enclosures with an "A" dimensionof 40" or more require a 3 pointdoor latching mechanism, order:one Allen Bradley 1494F-L2 andone 1494F-L3.
Space Occupied by DisconnectNote: "K" = 3.84 when "C" = 8.00
"K" = 6.75 when "C" = 10.00"K" = 9.50 when "C" = 12.00(except enclosures for 200A switches)"K" = 9.50 when "C" = 16.00"K" = 10.50 when "C" = 12.00(for enclosures with 200A switches)"P" = Wiring Space
Disconnects will occupy space on panel shown bydimensions "K", "L" and "M".
Wiring space "P" is available when disconnect is installed inthe enclosure.
*The disconnect information and space occupied tablesbased on data supplied by disconnect manufacturer’sbulletins. Hammond Manufacturing is not responsible fordimensional accuracy.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
145
Disco
nn
ect Enclo
sures
Wallm
ou
nt En
closu
res
Allen Bradley 1494F Disconnect Switches
Fits Allen- Space When When WhenFits Enclosure Depth Bradley Amp Fuse Fuse Occupied K=3.84 K=6.75 K=9.508 10 12 16 Type No. Rating Clip Class L M1 P P P
1 "M" dimension does not allow for auxiliary switches. Refer to Allen Bradley instructions if additional space is required.2 200 A switches can only be installed in Hammond Enclosures 1447AK122 and 1447AL122.
K=10.50" for these 12.00" enclosures
Allen Bradley 1494D Circuit Breaker Operators
Fits Enclosure Allen- Space When When WhenDepth Bradley Frame Frame Size Occumped K=3.84 K=6.75 K=9.50
8 10 12 16 Type No. Rating Breaker Type (3 Pole) L M P P P
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
160
Disco
nn
ect Enclo
sures
Wallm
ou
nt En
closu
res
1447SN4 Single Door Disconnect Enclosures - NEMA 4ABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
Collar studs are provided formounting inner panels.A removable 12 gauge inner panel isincluded.Oil resistant gaskets are permanentlysecured and mechanically retained.A bonding stud is provided on thedoor and a grounding stud is providedin the enclosure.A literature pocket is provided for theinside of the door.
Note:Disconnects and operatingmechanisms are not provided with theenclosure, and must be orderedseparately from the manufacturer.
FinishDoor and enclosure are phosphatizedand finished in ANSI/ASA 61 graypowder coating.Inner panel is finished in white powdercoating.
ApplicationDesigned to house the followingsafety disconnect equipment:
ABB Controls flange-mountedvariable depth operating mechanismfor disconnect switches and circuitbreakers.Allen Bradley 1494V variable depthflange mounted disconnect switchesand circuit breaker operators NEMA 4rated. Will not accept Allen Bradley1494F disconnect switches, 1494Dcircuit breaker operators or 1494V-R1, -R2, or -W2 operating handles.C-H Westinghouse C361 variabledepth flange mounted disconnectswitches and C371 circuit breakeroperators, and also Flex-Shaft™handle mechanism for circuit breakers.Use Cutler Hammer NEMA 4 ratedoperating handles to maintain NEMA 4integrity.General Electric Type STDA flangehandles and variable depth operatingmechanism for disconnect switchesand circuit breakers. Also Spectra-Flex™ cable operators for circuitbreakers.I-T-E Max-Flex™ flange mountedvariable depth handles for disconnectswitches and circuit breakers. Usehandle for NEMA 4.
Square D class 9422 disconnectswitches with flange-mounted variabledepth operating mechanisms or cablemechanisms and Class 9422 flange-mounted variable depth operatingmechanisms or cable mechanisms forcircuit breakers. SN4 enclosures willnot accept Square D Class 9422bracket-mounted disconnect devices,9422TG1 or TG2 devices.
StandardsUL 508 Type 3R, 4CSA Type 3R, 4Complies with
NEMA Type 3R, 4, 12JIC EGP-1-1967IEC 529, IP66
Appropriate components are requiredto maintain these standards.
ConstructionFormed 14 gauge steel.Continuously welded seams.Larger sizes include door and bodystiffeners.Welded brackets provide for enclosuremounting.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Cutouts and holes are provided to suitthe flange handle operatingmechanism.Continuously hinged doors may beremoved by pulling the hinge pin.Door is secured with easily operatedsteel clamps.Cover interlock bracket is welded tothe door.
36 9.0042 9.8848 11.3860 14.38Note: Number of door clamps varies to enclosure size.
➊➊ ➊➊ ➊
➋➋ ➋➋ ➋
➌➌ ➌➌ ➌
➍➍ ➍➍ ➍
➎➎ ➎➎ ➎
➏➏ ➏➏ ➏
➊ Vertical body stiffener req’d on 1447SN4G8only.
➋ Omit center body stiffener if A is less than 41".➌ Omit 2 middle studs if A is less than 31".➍ Omit body stiffeners if B is 28" or less.➎ Omit 2 middle studs if B is less than 32".➏ Omit door stiffener if B is 32" or less except
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
147
Disco
nn
ect Enclo
sures
1447S Single Door Disconnect Enclosures - NEMA 12, 13ABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
Note:Disconnects, operating mechanismsand door hardware are not providedwith the enclosure, and must beordered separately from themanufacturer.Enclosures with an "A" dimensionunder 40" require 2 point doorclosing hardware.Enclosures with an "A" dimension40" or more require 3 point doorclosing hardware.
FinishDoor and enclosure arephosphatized and finished in ANSI/ASA 61 gray recoatable powdercoating on the outside.Enclosure interior is finished in whitepowder coating.Inner panel is finished in whitepowder coating.
StandardsUL 508 Type 12, 13CSA Type 12, 13Complies with
NEMA Type 12 and 13JIC EGP-1-1967IEC 529, IP65
Appropriate components arerequired to maintain thesestandards.
ConstructionFormed 14 gauge steel.Continuously welded seams.Larger sizes include door and bodystiffeners.Welded brackets provide forenclosure mounting.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Cutouts and holes are provided tosuit the handle, operatingmechanism and door closingmechanism.Continuously hinged doors may beremoved by pulling the hinge pin.Latch pivots and cover interlockbrackets are welded to the door.Cover latch bars for door handlesare provided.Collar studs are provided formounting inner panels.A removable 12 gauge inner panel isincluded.Oil resistant gaskets arepermanently secured andmechanically retained.A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided.
ApplicationDesigned to house the following safetydisconnect equipment:
ABB Controls flange-mountedvariable depth operating mechanismfor disconnect switches and circuitbreakers.Allen Bradley 1494V variable depthflange mounted disconnect switchesand circuit breaker operators. Will notaccept Allen Bradley 1494Fdisconnect switches, 1494D circuitbreaker operators.C-H Westinghouse C361 flangemounted variable depth operatingmechanism with disconnect switchesand C371 flange mounted variabledepth operating mechanisms for circuitbreakers. Also Flex-Shaft™ handlemechanisms for circuit breakers.General Electric Type STDA flangehandles and variable depth operatingmechanism for disconnect switchesand circuit breakers. Also Spectra-Flex™ cable operators for circuitbreakers.I-T-E Max-Flex™ flange mountedvariable depth handles for disconnectswitches and circuit breakers.Square D class 9422 disconnectswitches with flange mounted variabledepth operating mechanisms or cablemechanisms and Class 9422 flange-mounted variable depth operatingmechanisms or cable mechanisms forcircuit breakers. Will not accept SquareD Class 9422 bracket-mounteddisconnect devices, 9422TG1 or TG2devices.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
148
Disco
nn
ect Enclo
sures
When A= M=
36 9.00
42 9.8848 11.38
60 14.38
➊➊ ➊➊ ➊
➋➋ ➋➋ ➋
➌➌ ➌➌ ➌
➍➍ ➍➍ ➍
➎➎ ➎➎ ➎
➏➏ ➏➏ ➏
➊ Vertical body stiffener req’d on 1447SG only.➋ Omit center body stiffener if A is less than 41".➌ Omit 2 middle studs if A is less than 31".➍ Omit body stiffeners if B is 28" or less.➎ Omit 2 middle studs if B is less than 32".➏ Omit door stiffener if B is 32" or less except if AxB
is 42"x31.38".
1447S Single Door Disconnect Enclosures - NEMA 12, 13ABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
1447SL16 60 37.38 16 57 33 31.38 61.25 265 I2 Center stiffener; N = Not Included I = Included
Space Occupied by DisconnectNote: "K" = 4.75 when "C" = 8.00
"K" = 7.09 when "C" =10.00"K" = 11.62 when "C" =12.00"K" = 11.62 when "C" =16.00"K" = 18.38 for 1447S46L12"P" = Wiring Space
Disconnects will occupy space on panelshown by dimensions "K", "L" and "M".
Wiring space "P" is available when disconnectis installed in the enclosure.
*The disconnect information and spaceoccupied tables based on data supplied bydisconnect manufacturer’s bulletins. HammondManufacturing not responsible for dimensionalaccuracy.
door hardware (as required1):DKR2 for 2 point latchingDKR3 for 3 point latching as required
Square DClass 9422 disconnect switch:
disconnect switch and operatingmechanism: Class 9422handle mechanism: Type A-1door hardware (as required1):
Class 9423-M4 or M9 for 2 point latchingClass 9423-M4 or M9 and 9423-M3 for3 point latching
Class 9422 circuit breaker:circuit breakeroperating mechanismhandle mechanism: Type A-1door hardware (as required1):
Class 9423-M4 or M9 for 2 point latchingClass 9423-M4 or M9 and 9423-M3 for3 point latching
Class 9422 Type “T” disconnect switch with cablemechanism:
disconnect switch and operatingmechanism: Class 9422, Type Thandle mechanism: Class 9422 Type A-1cable mechanism: Class 9422 CFT_O -3, 5 or 10 footdoor closing mechanism (as required1):
Class 9423 Type M4 for 2 point latchingClass 9423 Type M9 or M4 and Class9423 Type M3 for 3 point latching
Circuit breaker with cable mechanism:circuit breaker: Square Dhandle mechanism: Class 9422 Type A-1cable mechanism: Class 9422 CFT_O -3, 5 or 10 footdoor closing mechanism (as required1):
Class 9423 Type M4 for 2 point latchingClass 9423 Type M9 or M4 and Class9423 Type M3 for 3 point latchingNote: 1 To determine door latching requirements (2 or 3 point latching) please see
notes under construction information.
1447S Single Door Disconnect Enclosures - NEMA 12, 13ABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
1 J type fuse clips are standard. If 600 V Type “T” fuse clips are desired order T type fuse adaptor kit.2 200 A available by using non-fusible 200A switch and a trailing fuse block. (consult ABB)
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
152
Disco
nn
ect Enclo
sures
Wallm
ou
nt En
closu
res
1447S Single Door Disconnect Enclosures - NEMA 12, 13ABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square DAllen BradleyAllen Bradley 1494V Disconnect Switches
Fits Allen Bradley Space When When WhenEnclosure Depth Type Amp Fuse Fuse Occupied K=4.75 K=7.09 K=11.62
1 "M" dimension does not allow for auxiliary switches. 2 Series B3 The 400 amp disconnect switch and the 600 amp switch will only fit catalog number 1447S46L12. Wire bend space of 12.12 inches is provided above disconnect when installed.4 "L" and "M" do not include separately mounted fuse blocks
Allen Bradley 1494V Circuit Breakers
Fits Allen Bradley Space When When WhenEnclosure Depth Type Amp Fuse Fuse Occupied K=4.75 K=7.09 K=11.62
1 Wire bend space "P" does not allow the use of maximum cable size in 8" deep enclosures.2 200A switch should be installed in enclosures with an "A" dimension of 30" or greater.
Part numbers for Complete Operator Mechanisms include flange mounted handle, flexible shaft and circuit breaker mechanism.The last digit of the part number denotes the shaft length (F1S03=3' length).
F,J,K frame Flex-Shafts™ available in 3' to 10' lengths.L,N,R frame Flex-Shafts™ available in 4' to 6' lengths.
Space Occupied By Disconnect1. Flex-Shaft™ System permits circuit breaker locations separate from flange mounted handle mechanism.2. See National Electrical Code 1996 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 4" minimum bending radius for the Flex-Shaft™.4. Space occupied by circuit breaker is calculated by:
overall (Height "X" and Width "Y")minimum wire bend space (manufacturer specified)location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing...see page 149.
• • TDOM2 200A 200A-600V H, R 15.38 9.12 — — 9.501 Disconnect moved down 0.875" to fit on panel.2 Applies to 8" deep enclosures and is 0.875 less in 10", 12" and 16" deep enclosures.
General Electric Type STDA Circuit Breaker Operators
Fits General Electric Space When When WhenEnclosure Depth Mechanism Amp Occupied K=4.75 K=7.09 K=11.62
• • SD0M4 600A SPECTRA SG600 10.00 7.00 — — 7.931 Disconnect moved down 0.875" to fit on panel.2 Applies to 8" deep enclosures only. For 10", 12" and 16" deep enclosures, 0.875 less.
Charts reference Space Occupied by Disconnect Drawing...see page 149.
1 Operating Cables are available 3' to 10' lengths. In the table above, the number "3" in the part number indicates a 3' cable.
1. GE Spectra-Flex™ Operating Cables permit circuit breaker locations separate from flange mounted handle mechanism.2. See National Electrical Code 1996 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.3. Select shaft length based on location of circuit breaker in the enclosure. Maintain a 3" minimum bending radius for the Flex-Shaft™.4. Space occupied by circuit breaker is calculated by:
overall (Height "X" and Width "Y")minimum wire bend space (manufacturer specified)location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing...see page 149.
Last three digits of operator mechanism part number denote cable length in inches.48" cables are offered for ED,FD,JD/LD operators
Space Occupied By Disconnect1. I-T-E Max-Flex™ System permits circuit breaker locations separate from flange mounted handle mechanism.2. See National Electrical Code 1996 article 430-10(b) for wiring space (Ref “P”) needed for line side conductors.3. See Siemens I-T-E instructions for disconnect location limitations when using 36" or 48" Max-Flex™ cables.4. Space occupied by circuit breaker is calculated by:
overall (Height "X" and Width "Y")minimum wire bend space (manufacturer specified)location "M" from right to left.
Charts reference Space Occupied by Disconnect Drawing...see page 149.
Use cable mechanism with circuit breaker and 9422-A1 handle mechanismCable operators are offered in 3’, 5’, and 10’ lengths. Last 2 digits of part numbers above (30) are for 3’ cables
Space Occupied By Disconnect Switch1. Square D Cable System permits circuit breaker locations separate from flange mounted handle mechanism.2. See National Electrical Code 1996 article 430-10(b) for wiring space (Ref "P") needed for line side conductors.3. Select cable mechanism length based on disconnect location in enclosure. See Square D instructions for minimum cable bend radius.4. Space occupied by circuit breaker is calculated by:
overall (Height "X" and Width "Y")minimum wire bend space (manufacturer specified)
Charts reference Space Occupied by Disconnect Drawing...see page 149.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
162
Disco
nn
ect Enclo
sures
Wallm
ou
nt En
closu
res
1447SN4SS Stainless Steel Single Door Disconnect Enclosures - NEMA 4, 4XABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
InnerPanel
Included
ApplicationDesigned to house the following safetydisconnect equipment:
ABB Controls flange mounted variabledepth operating mechanisms fordisconnect switches and circuit breakers.Allen Bradley 1494V variable depthflange mounted disconnect switchesand circuit breaker operators NEMA 4rated. Will not accept Allen Bradley1494F disconnect switches, 1494Dcircuit breaker operators or 1494V-R1, -R2, or -W2 operating handles).Cutler Hammer C361 variable depthflange mounted disconnect switchesand C371 circuit breaker operators.Also Flex-Shaft™ handle mechanismsfor circuit breakers. Use Cutler HammerNEMA 4 rated operating handles tomaintain NEMA 4 integrity.I-T-E Max-Flex™ flange mountedvariable depth handles for disconnectswitch and circuit breakers. Use handlefor NEMA 4 rating.General Electric Type STDA flangehandles and variable depth operatingmechanisms for disconnect switches andcircuit breakers. Also Spectra-Flex™cable operators for circuit breakers.Square D Class 9422 disconnectswitches with flange mounted variabledepth operatingmechanisms or cablemechanisms and Class 9422 flangemounted variable depth operatingmechanism or cable mechanisms forcircuit breakers. SN4SS enclosures willnot accept Square D Class 9422bracket-mounted disconnect devices,9422TG1 or TG2 devices.
A bonding stud is provided on thedoor and a grounding stud isprovided in the enclosure.A literature pocket is provided for theinside of the door.
Note:Disconnects and operatingmechanisms are not provided withthe enclosure, and must be orderedseparately from the manufacturer.
FinishDoor and enclosure are natural,brushed stainless steel.Inner panel is finished in whitepowder coating.
StandardsUL 508 Type 3R, 4 and 4XCSA Type 3R, 4 and 4XComplies with
NEMA Type 3R, 4, 4X, 12 and 13JIC EGP-1-1967IEC 529, IP66
Appropriate components arerequired to maintain thesestandards.
ConstructionFormed 14 gauge type 304 stainlesssteel.Continuously welded seams.Larger sizes include door and bodystiffeners.Formed lip on door and enclosureexclude flowing liquids andcontaminants.Cutouts and holes are provided tosuit the flange handle operatingmechanism.Continuously hinged doors may beremoved by pulling the hinge pin.Door is secured with easily operatedsteel clamps.Cover interlock bracket is welded tothe door.Collar studs are provided formounting inner panels.A removable 12 gauge inner panel isincluded.Oil resistant gaskets arepermanently secured andmechanically retained.
Technical references and DXF downloads available at www.hammfg.com All dimensions in inches unless specified otherwise
163
Disco
nn
ect Enclo
sures
1447SN4SS Stainless Steel Single Door Disconnect Enclosures - NEMA 4, 4XABB Controls, Allen Bradley, Cutler Hammer, General Electric, I-T-E Max-Flex™, Square D
Wallm
ou
nt En
closu
res
Note: Number of door clamps varies to enclosure size.
Panel Size Mounting Centers ShipPart No. A B C D E F G Wt. lbs.
➊ Vertical body stiffener req’d on1447SN4SSG8 only.
➋ Omit center body stiffener if A is less than 41".➌ Omit 2 middle studs if A is less than 31".➍ Omit body stiffeners if B is 28" or less.➎ Omit 2 middle studs if B is less than 32".➏ Omit door stiffener if B is 32" or less except